HomeMy WebLinkAbout1029 GOLDENEYE VW; ; CB061791; Permit''{ City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
09-08-2006 Patio/Deck Permit Permit No: CB061791
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
1029 GOLDEN EYE VW CBAD
PATIO
2110900100
Status:
Lot#: 0 Applied:
Valuation: $3,360.00 Construction Type: NEW Entered By:
Reference #:
Project Title: STREET RES: 224 SF DECK PER
Plan Approved:
Issued:
lnsp·ect Area:
CITY SPECS/FIRE ZONE=STUCCO& METAL Plan Check#:
Applicant:
EASTERLING CONSTRUCTION
1262 GRANDVIEW
VISTA CA 92084
760 639-0371
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Strong Motion Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Additional Fees
TOTAL PERMIT FEES
Owner:
STREET ROBERT&DEBORAH
1029 GOLDEN EYE VW
CARLSBAD CA 92011
ISSUED
06/22/2006
JMA
06/22/2006
06/22/2006
JM
$53.49
$0.00
$34.77
$0.00
$1.00
$0.00
$0.00
$0.00
$0.00
$89.26
Total Fees: $89.26 Total Payments To Date: $89.26 Balance Due:
Inspector:
FINAL ifLPROV. AL
Date:VV\. Clearance: ------
$0.00
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired.
FOR OFFICE USE ONLY
PERMIT APPLICATION PLAN CHECK NO.Cf()~ I~ I
EST. VAL. 3300 CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008 Plan Ck. Deposit---+~¥------
1. PROJECT INFORMATION
Business Name (at this address)
Legal Description .-lot No. Subdivision Name/Number Unit No. Phase No. Total # of units
Assessor'sParcelZ.//-tJ9{) ~()/ -OO Existing Use Proposed Use
Description of Work
VeCJC.. #of Stories (I 1 # o! Bedrooms I _ 1# J2f Bathrooms I -1\re res.is-f-,...e Con<;-r-rve...,, or,
2. CONTACT PERSON (If different from applicant)
Telephone # Fax#
3.
4. PROPERTY OWNER
73~ B 5Tl21::IT
Name A:ddress City S.tate/Zip Telephone#
6. C6NTAACTOR • COMPANY NAME
(Sec. 7031 .5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's license law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
ee&&~WIY\~ttio~Ajb$~ appl~r~ermMo~tJbca0ra c~/,s1-J of 04ore 92~~~dre7~~rs ~3?,0 3 71
Name Address City State/Zip Telephone #
State license # 7 3 I i2 I o · License Class ,3 ft ity Business license # --------
Designer Name Address City State/Zip Telephone
State license # ----------
8. WORKERS' COMPENSATION
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the labor Code, for the performance
of the work for which this permit is issued.
0 I have and will maintain workers' compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are:
Insurance Company Policy No. Expiration Date _______ _
~IS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS) /::!-. CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compe ation laws of California .
• ---un-1-aw--...and shall subject an employer to criminal penaltlea and civil fines up to one hundred
thousand dollars ($100,0 magea as provided for in Section 3706 of the)-abor code, interest,: attorney's fees.
SIGNATURE=---./--_..t;.,4~.e::::::~-.:::::::::~=======z!:::::=----==-DATE ~ -'Ll=:-GJ ~
7. ()~~-BUILDER
I hereby affirm that I am exempt from the Contractor's license law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 i, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's license law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's license law).
0 I am exempt under Section ------Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO
2. I (have I have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number I contractors license number):-------------------------------------------------
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address / phone number / type of work): _______________________________________________________ _
PROPERTY OWNER SIGNATURE ______________________ _
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
DATE __________ _
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act7 0 YES O NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O YES O NO
I~ the facility to be constructed within 1,000 feet of the outer boundary of a school site 7 0 YES O NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
8. ~9!,!STRUCTIO~ Ll;NDING AGE_NCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME--------------
9. APPLICANT CERTIFICATION
LENDER'S ADDRESS ________________________ _
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit\' of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every pen~it issued by the building Offici under the provisions of this Code shall expire by limitation and become null and void ii the building or work
authon~ed by such permit 1s not commenc m 1 s from the · ilding or work authorized by such permit is suspended or abandoned
at any lime after the work 1s commenc for a p r' 180 days (Section 106 n form Building Code).
DATE
PINK: Finance
City of Carlsbad Bldg Inspection Request
For: 04/~2007
Permit# CB061791 f\ lnspectqr Assignment: _J_M __
Title: STREET RES: 224 SF DECK PER
Description: CITY SPECS/FIRE ZONE=STUCCO& METAL
Type: PATIO Sub Type:
Phone: ft 9 ~ '? 1 l/
Job Address: 1029 GOLDENEYE VW
Suite: Lot: 0
Location Inspector: -----
OWNER STREET ROBERT&DEBORAH
Owner: STREET ROBERT&DEBORAH
Remarks: final deck
Total Time: Requested By: ROBERT
Entered By: CHRISTINE
CD Description Act Comments
19 Final Structural ~------
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
lnsr2ection History:
Date Description Act lnsp Comments
01/17/2007 19 Final Structural co JM GAP GREATER THAN 4"
10/30/2006 17 Interior Lath/Drywall WC JM
10/30/2006 19 Final Structural co JM GUARD RAIL NOT 361N
10/27/2006 18 Exterior Lath/Drywall WC JM
10/27/2006 19 Final Structural co JM COMPLETE GUARD RAIL
09/28/2006 18 Exterior Lath/Drywall AP JM
09/07/2006 14 Frame/Steel/Bolting/Welding AP JM DECK & DOOR
09/07/2006 34 Rough Electric AP JM
09/05/2006 14 Frame/Steel/Bolting/Welding co JM LEDGER BOLTS & ROMEX
08/30/2006 14 Frame/Steel/Bolting/Welding co JM DOG IN BACK YARD
),
' City of Carlsbad Bldg Inspection Request
For: 09/05/2006
Permit# CB061791
Title: STREET RES: 224 SF DECK PER
Description: CITY SPECS/FIRE ZONE=STUCCO& METAL
Type: PATIO Sub Type:
Job Address: 1029 GOLDENEYE VW
Suite: Lot 0
Location:
APPLICANT EASTERLING CONSTRUCTION
Owner: STREET ROBERT&DEBORAH
Remarks: PATIO?
Total Time:
Description CD
14 Frame/Steel/Bolting/Welding
Comments/Notices/Hold
Associated PCRs/CVs Original PC#
Inspection History
Date Description Act lnsp Comments
Inspector Assignment: JM ---
Phone: 7608057660
Inspector: ----
Requested By: ROBERT
Entered By: JANEAN
08/30/2006 14 Frame/Steel/Bolting/Welding CO JM DOG IN BACK YARD
\
\ -·
i-
i-.....:.----t --- - - - -
'5'1(\ Et"\\ ~'i
~\)~6 I
A-N °'''· oqo •°-I ·llOJ
I
....
JUN 2 2 2006 ,,
-------,.-t--'-------1-.------L--------··--·--
-,.,~"::=-~x,m~=--~-~-· •=-· _ ___._,_,"'" ----·--/ o 2" -c-;1d;~· -· ·-~-Vt&V~--· --· -
O';Obl7qf
City of Carlsbad
i=i!N•G••li·l•l=i·Fiii;,14;11
RESIDENTIAL DECKS
A Building Permit is required for residential decks more than 30 " above grade. This
hand out describes what plans are necessary to secure a deck permit. To assist you,
there is a sample of a plot plan, span tables for joists, girders, and beams, and there is
a footing schedule for foundation requirements. There are also connection details to
use for typical connections. If you design the deck yourself, or if your deck is free-
standing or outside the table limits in this handout, please provide a foundation plan,
framing details, and other details and elevations to show the extent of the proposed
work. A complete structural analysis may be required for decks outside the scope of
this handout.
If you use the attached tables and plans please submit:
1 .. Two Identical Site Plans showing:
I. Property lines with dimensions.
2. Proposed deck and stairway (if applicable}.
3. Distances from posts to property lines.
4. All existing structures on the property.
5. Indicate the dimensions of the deck and the total deck square
footage.
6. Any easements on the property.
2. A Building Permit Application with the following:
a. Name of the property owner.
b. Home Phone Number
c. Site address, assessor's parcel number, lot number, subdivision name or
number.
d. Contractor's name, State License Number and City Business License
Number; or an Owner-Builder Declaration Form (Available at the Building
Department Counter).
e. Signature of Applicant
If you are applying for a building permit in a subdivision with a homeowner's
association,-}'_01;1-sf}ould ,seeu.r~~rchiteQtt:,r,~Lreview~rior to proc~eding wit!) t~ _
project. The Cityuoes not enforce or specifically review provisions-'Of homeowners'
association CC&R's. HOA requirements may be different than City requirements.
If you are applying for a building permit in the Coastal Zone, you may need a Coastal Development Permit or an exemption.
Contact the Planning Department for details. A Coastal Zone map is part of this handout. If you are applying for a building permit
in a subdivision with a homeowner's association, you should secure architectural review prior to proceeding with the project. The
City does not enforce or specifically review provisions of homeowners' association CC&R's. HOA requirements may be different
than City requirements. If your home is part of a Planned Unit Development or a condominium, please see text of this handout.
Revised 2,7,00
1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2700 • FAX (760) 602-8560 @
Building Counter • (760) 602-2719 • FAX t7Rm i::n•::u:1&:::1:::0
SETBACKS FOR R-1 PARCELS
FRONT YARD -20' from front
property lne
IIITERIOR SOE Y ARO -10% of
lot wiclh up to e maximum of
1 O'
STREET SDE YARD - 1 CJ
REAR YARD -20% of lot width
up to maximum of 20 feet
MAX. LOT COVERAGE -40%
Coriact the Plamng Depertment
tor Information on comer lots or
lots wlh ln.lSU8I configi.ntions
80d for Information on Pl«lned
Communlies, accessory
struc:t11es, end bulclng
heights.
The telephone number for the
Pl8nning Depertmert Is
438-1161.
I'
(
10%
I -.J
20%of LOT
REAR YARD \l\,f)TH TO A
MAX.OF 20'
EXISTIIIG RESDENCE
~ ~ DRAINAGE 2% IYWIJ. --------1-
20'
STREET
\
J
• I
Minimum Square Footing Sizes (lnches)1.2
Post
Spacing
4 6 8
4 12 14 16
6 -14 -j6 -20
8 16 --20 ~ 22 -
1Q 18 22 24
I 12 ) 20 24 28 -
1. Assumes 1,000 psr soil bearing capacity
2. The minimum depth ror all rootlngs Is 12 Inches Into natural grade
Joist
Span
(feet)
10
18
22
24
28
32
12
20
24
26
30
32
,
I
14 16
20 f::22
24 28
28 ---30
~ 34
·36 l 36
10%0F
LOT V't1DTH
UP TOA
LOT WDTH MEAS~ED 20'
FROM 2r:J BACK OF
FRONT PROPERTY LINE
PROPERTY LN:
18
24
30
32
36
38
ALLOWABLE RESIDENTIAL DECK JOIST SPANS1·2
/
DOUG. FIR REDWOOD FLOOR
SIZE SPACING FLOOR JOISTS JOISTS
2X4 12" 6'3" 6'3"
16" 5'6" 5'6"
24" 5'0" 5'0"
2X6 12" 9'9" 9'9"
16" 8'9" 8'9"
24" 7'9" 7'9"
2XB 12" 12'9" 12'9"
16" 11'9" 11'9"
24" 10'2" 10'3"
2 X 10 12" 16'5" 16'5"
16" 15'0" 15'0"
24" 13'0" 13'0"
..... -( 2X12 J 12" 20'0" 20'0".
~ 18'0" 18'0"
15'10" 15'10"
2 X 14 12" 22'9" 22'6"
16" 19'9" 21'0"
24" 16'0" 17'0"
1. Assumes a live load of 40 psf and a dead load of 8 psf.
2. If joists are within 18" of grade, use pressure treated Douglas Fir-Larch or Foundation Grade Redwood
3. Assume F(b)=825 psi, F9v)=90 psi, and E=1,200,000 psiforD.F. #2
4. Assume. F(b)=925 psi, F9v)=80 psi, and E=1,200,000 psi for Redwood
Allowable Beam Spans
Post Joist span
Spacing (feet) ~ (feet)
4 6 8 10 12 l..;Y 16
4 4x4 4x6 4x6 4x8 4x10 4x10 4x14
6 4x6 · 4x8 4x8 4x10 4x10 4x14 4x14
6x8 6x8 6x10 6x12
8 4x10 4x10 4x12 4x12 4x14 4x14 4x16
6x8 6x8 6x10 6x10 6x10 6x12 6x12
10 4x10 4x14 4x14 4x16 4x16 4x18 6x16
6x10 6x12 6x12 6x14 6x14 6x14
I:& . ~ .-...... ~ I ._
' 12 ']
4x10 4x14 4x14 4x16 ( ~ J~ 4x18) 6x16
6x10 6x12 6x12 6x14 6x14 --,-
\.._
'-..___/
l
Typical deck
Post-to-girder connection
case 1/End condition
Post cap
instaBecl per
manufaclUrer's
installation
instructions
For ledger to
unit attachment
see Section VI, Item D.
Min. 18ga.
U-type hanger
!<-2';,:;:.imum~ ~1s• minimum Provide 4x4
knee brace or top-to-bottom
brace on lhe
interior side of all post-to-beam
connections
when post
height exceeds
4'-0"
case 2/lnterior condition
Post cap
installed per
manufacturer's
installation
instructions
18" minimum~
Two t/2 "0 lag ,.. _ __.. ___ bolts top and __ ........__-;~
bottom typical