Project Title: MCINNIS RES= REMOVE APPROX
114 SF OF HABITABLE SPACE FROM LAUNDRY/UTILITY ROOM TO
ACCOMODATE DRIVEWAY ACCESS. MINOR P/M/E UPGRADE TO 200A
ELECT PANEL
Applicant:
MCINNIS SAMUEL&SHEILA
1030 MAGNOLIA AVE
CARLSBAD CA 92008
951-691-7255
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
STD #2 Fee
STD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB 14 73) Fee
Green Bldg Stands Plan Chk Fee
Total Fees:
Inspector:
$310.09
$0.00
$217.06
$0.00
$0.00
$4.55
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$2.00
$0.00
Total Payments to Date:
Owner:
MCINNIS SAMUEL&SHEILA
1030 MAGNOLIA AVE
CARLSBAD CA 92008
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWAFee
CFO Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnLieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
Fire Sprinkler Fees
TOTAL PERMIT FEES
$697.95 Balance Due:
FINAL APPROVAL
Date: lf~lq-1<:: Clearance:
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$56.00
$45.00
$63.25
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$697.95
$0.00
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any . .
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
04-13-2015
Storm Water Pollution Prevention Plan (SWPPP) Permit
Permit No:SW150112
Job Address:
Permit Type:
Parcel No:
Reference #:
CB#:
Project Title:
Applicant:
1030 MAGNOLIA AV CBAD
SWPPP
2051911100
CB150478
MCINNIS RESIDENCE: NEW
MCINNIS SAMUEL&SHEILA
1030 MAGNOLIA AVE
CARLSBAD CA 92008
Emergency Contact:
SAM MCINNIS
951-691-7255
SWPPP Plan Check
SWPPP Inspections
Additional Fees
TOTAL PERMIT FEES
Status:
Lot#: 0 Applied:
Entered By:
Issued:
Inspect Area:
Tier:
Priority:
Owner:
MCINNIS SAMUEL&SHEILA
1030 MAGNOLIA AVE
CARLSBAD CA 92008
ISSUED
03/11/2015
JMA
04/13/2015
1
M
$53.00
$224.00
$0.00
$277.00
Total Fees: $277.00 Total Payments To Date: $277.00 Balance Due:
FINAL APPROVAL
SIGN~TUFE __
$0.00
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: □PLANNING □ENGINEERING □BUILDING □FIRE □HEALTH 0HAZMAT/APCD
{"city of Building Permit Application Plan Check No.d.P,.\5'478
1635 Faraday Ave., Carlsbad, CA 92008 Est. Value ,35.a,o
Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit ,111,. O(p Carlsbad email: building@carlsbadca.gov
www.carlsbadca.gov Date .:l.1(3J 1C:. lswPPP IS. ( I?-
JOB ADDRESS /()-00 f(JQQNOliA. A /£
SUITEI/SPACEI/UNITI IA~':) 11 -I G\ \ --Ob
CT/PROJECT# rOT # . I PHASE# # OF rlTS
1
# BEDROOMS # BATHROOMS I TENANT BU::dNESS NAME I CONSTR. TYPE I occ. GROUP
CAl21-f,5AD
DESCRIPTION OF WOnn.: Include Squa,e Feet of Affected Atea(s)
'R.E.mov G IH -&q F~ FtZOtv\ .Q..<'STTN!f vtiLiry ~ +, ltC.C,..:,IJ/l~~ 1)1).\Ve.
A~<;'!?$ ll£€.1? Sp~ A<; v+1Lt1'y ~-upqrade. ~ rf\,,/'-01 p~ ,i... ~
EXISTING USE I PROPOSED USE I GARAGE {SF) PATIOS (SF) I DECKS (SF) FIREPLACE 1 IAIR CONDITIONING I FIRE SPRINKLERS
YESO "'° YES□No□ YES□No□
APPLICANT NAME PROPERTY OWNER SAM McrM,,,·.,, Prlmarv Contact
ADDRESS ADDRESS
lo"?r, JY1 "·' ., -, I , fl CJ,r~
CITY STATE ZIP CITY STATtc.,A. ZIP q 2.,(X)8 GA·oJ-..., ~.f)
PHONE IFAX PHONE 9S/ -IJ/1.1-7~~ IFAX
EMAIL EMAIL
<:.n M-,~a. W\' "r A'l A7r. Net' ,,.,q_ SfYJe,,innic7l5~
DESIGN PROFESSIONAL CONTRACTOR BUS. NAME '--fMA I\..-•"17
ADDRESS ADDRESS
CITY STATE ZIP CITY STATE ZIP
PHONE IFAX PHONE IFAX
EMAIL EMAIL
STATE UC.# STATE UC.# I CLASS I CITY BUS. UC.#
(Sec~ 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any_ structure, p:nor to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law {Chaoter 9, commendmgwith Section 7000 of Division 3 of the Business and Professions Code} or that he is exemP.t therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ('500}).
WORKERS' COMPENSATION
Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: D I have and wlll maintain a certificate of consent to self-Insure for workers' oompensation as provided by Section 3700 of the Labor Cade, for the per1ormance of the work for which this permit is issued. D I have and will maintain workers' compensation, as reQUired by Section 3700 of the Labor Code, for the pertormance of the work for which this oennit is issued. My workers' compensation insurance earlier and policy
number are: Insurance Ca .. ______________________ Policy No. ______________ Expiration Date _________ _
This section need not be completed if the permit is for one hundred dollars ($100) or less. 0 Certificate of Exemption: I certify that in the pertormance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worl(ers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage Is unlawful, end shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In
addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code, Interest and attorney's fees.
JI! CONTRACTOR SIGNATURE □AGENT DATE
OWNER-BUILDER DECLARATION
I hereby affirm that I am exempt from Contractor's Ucense Law for the following reason: D I, _as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
;z( sale. If, however, the building or improvement is sold within one year of completion, the owner•builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct_the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and oontrocts for such projects with contractor(s) IK:ensed pursuant to the Contractor's License Law). D I am exempt under Section ____ ~,Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Oves ONo
2. I (have/ have not) signed an application for a building permit for the proposed wort(
3. I have contracted with the following person (firm) to provide the proposed co structlon (Include name address I phone I contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person ooordinate, supervise and provide the major work (include name/ address/ phone I contractors' license number):
5, I will provide some of the work, but I have oontracted (hired) the lollowin persons to provide the work indicated (include name I address I phone/ type of work):
JI! PROPERTY OWNER SIGNATURE □AGENT DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act.? Yes No
Is the applicant or future building occupant required to obtain a pennil from the air pollution control district or air ciuality manar;iement district? Yes No
Is the facility to be constructed within 1,000 feel of the outer boundary of a school site? Yes No
IF ANY OF THE ANSWERS ARE YES, A ANAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
ONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work this perrmt 1s issued (Sec 3097 (1) CIvII Code)
lender's Name lender's Address
APPLICANT CERTIFICATION
I certify that I have read the appllcatlon and state that the above Information Is co11'8Ctand that the lnfonnation on the plans Is accurate. I agree to oomply\Wth all City ordinances and Stats laws relating tD bullding construction.
I hereby aulhorize representativeof fue Cfy of Carlsboo to enter upon fue above rrenfuned i,uperty !Jr inspection purposes. I ALSO AGREE TO SAVF., INDEMNIFY AND KEEP HARMLESS THE CrTY OF CARLSBAD
AGAINST All. LlABIUTIES, JUDGMENTS, COSTS AND EXPENSES WHICH YIN ANY WAY ACCRUE AGAINST SAID CrTY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: AA OSHA permit is requi'ed br excavations over 5'0' deep and demolltbn oonstruction of structures over 3 sbre5 in height.
EXPIRATION: Every permit issued by · ·ng Offdal under the ~visbns of is Code shall expire by Imitation and OOCXJme nun and void ff lhe buik:ltng or~ authorized by such permit is notoommenced wthin
180 days mn the date of such pe · orjf. buikiing or authorized bys permit is suspended or abandoned at anytime after !he ViOrl<. is oommenced klr a perkxl of 180days (Section 100.4.4 Uniklrm Buik:lhg Code).
I,·
.fiS APPLICANT'S SIGNATURE DATE c~ IS
• . STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE .
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
Fax (760) 602-8560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
CO#: (Office use Only)
CONTACT NAME OCCUPANT NAME
ADDRESS BUILDING ADDRESS
CITY STATE ZIP CITY STATE
Carlsbad CA
PHONE FAX
EMAIL OCCUPANT'S BUS. LIC. No.
DELIVERY Ol'llONS
PICK UP: CONTACT (Listed above) OCCUPANT (Listed above)
CONTRACTOR (On Pg. 1)
MAIL TO: CONTACT (Listed above)
CONTRACTOR (On Pg. 1)
OCCUPANT (Listed above)
MAIL/ FAX TO OTHER: _______________ _
.IS APPLICANT'S SIGNATURE
ASSOCIATED CB#-------------
NO CHANGE IN USE/ NO CONSTRUCTION
CHANGE OF USE/ NO CONSTRUCTION
DATE
ZIP
Inspection List
Permit#: CB150478 Type: RESDNTL RAD MCINNIS RES= REMOVE APPROX
114 SF OF HABITABLE SPACE FROM LA
Date Inspection Item Inspector Act ---------Comments
11/18/2015 89 Final Combo RI
11/18/2015 89 Final Combo PB AP
11/16/2015 89 Final Combo RI AM PLS
11/16/2015 89 Final Combo PB NR
09/16/2015 17 Interior Lath/Drywall PB AP
09/16/2015 18 Exterior Lath/Drywall PB AP
08/18/2015 84 Rough Combo PB AP
05/29/2015 33 Service Change/Upgrade PB AP
05/27/2015 13 Shear Panels/HD's PB AP
05/04/2015 13 Shear Panels/HD's PB CA
05/01/2015 11 Fig/Foundation/Piers PB AP
Wednesday, November 18, 2015 Page 1 of 1
DATE: 03/10/2015
JURISDICTION: Carlsbad
PLAN CHECK NO.: 15-0478
EsGil Corporation
In (J'artnersfiip witfi government for <Bui{tfing Safety
SET II
PROJECT ADDRESS: 1030 Magnolia Ave.
PROJECT NAME: Mcinnis Residence SF remodel.
□ APPLICANT
□ JURIS.
□ PLAN REVIEWER
□ FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ EsGil Corporation staff did not advise the applicant that the plan check has been completed.
D EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted: (by:
Telephone#:
) Email:
Mail Telephone Fax In Person
~ REMARKS: 1. Designer to sign all sheets prior to issuance. 2. See clouded note Sheet A3.3
and match to all sets. 3. City to place soils notice stamp on plans prior to issuance.
By: Kurt Culver (DA)
EsGil Corporation
D GA D EJ D MB D PC
Enclosures:
03/03/2015
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: 02/19/2015
JURISDICTION: Carlsbad
PLAN CHECK NO.: 15-0478
EsGil Corporation
In (['artnersfiip witfi government for /JJui{aing Safety
SET: I
PROJECT ADDRESS: 1030 Magnolia Ave.
PROJECT NAME: Mcinnis Residence SF remodel.
□ PLAN REVIEWER
□ FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Sam Mcinnis
D EsGil Corporation staff did not advise the applicant that the plan check has been completed.
~ EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Sam Mel~ Telephone#: (951)691-7255
Date contacted: Z ,..,.{q (b~ ) Email: samfam698@att.net
.tMail X Telephone,_i ti\, Fax In Person
0 REMARKS:
By: Kurt Culver (DA)
EsGil Corporation
□ GA □ EJ □ MB □ PC
Enclosures:
02/17/2015
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad 15-0478
02/19/2015
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 15-0478 JURISDICTION: Carlsbad
PROJECT ADDRESS: 1030 Magnolia Ave.
FLOOR AREA: 270 sq. ft
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 02/13/2015
DATE INITIAL PLAN REVIEW
COMPLETED: 02/19/2015
FOREWORD (PLEASE READ):
STORIES: 1
HEIGHT: 15ft
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 02/17/2015
PLAN REVIEWER: Kurt Culver (DA)
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2013 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC,
2012 UPC, 2012 UMC and 2011 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2012 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad 15-0478
02/19/2015
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
• PLANS
1. Indicate on the Title Sheet of the plans the name of the legal owner and name of
the person responsible for the preparation of the plans. Section R 106.1.1.
2. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
3. Plans state: "SUBMITTAL SET -NOT FOR CONSTRUCTION". The plans
cannot be approved with this note as the approved set will be the construction
set.
• FIRE PROTECTION
4. Specify on the plans that any existing smoke alarms that are more than 10
years old will be replaced. Section R314.3.2.
• GENERAL RESIDENTIAL REQUIREMENTS
5. Show that ceiling height for habitable rooms, hallways, bathrooms, toilet rooms,
laundry rooms and basements shall have a ceiling height of not less than 7 feet.
Section R305.1
6. Interior and exterior doors shall be provided with landings not more than 7-¾"
below the top of the threshold. Exception: A landing is not required where a
stairway of 2 or fewer risers is located on the exterior side of the door, provided
the door does not swing over the stairway. Section R311.3.2.
Carlsbad 15-0478
02/19/2015
• FOUNDATION REQUIREMENTS
7. Note on plans that surface water will drain away from building and show drainage
pattern. The grade shall fall a minimum of 6" within the first 1 0 feet. Section
R401.3.
• FRAMING
8. Show stud height and spacing on the plans. Maximum allowable stud heights
shall be per Table R602.3(5).
a) Show the stud height at the new bearing wall. Since you are removing
sloped roof in this area this wall will be significantly higher than the
existing, and I cannot determine if the stud height meets requirements.
9. You have chosen to use the conventional construction bracing
provisions outlined in the CRC. Provide documentation to show that the plans
comply with the Braced Wall provisions of Section R602.10. Include the
following:
a) Documentation to show there are sufficient Braced Wall Lines in the
building, per Section R602.10.1.4.
i) Please show location and length of existing braced walls. It looks
likely that the wall that is to be removed would have been a braced
wall.
b) The Braced wall panel at the shortened wall scales at 2.5' and will require
hold-downs. Also to meet the provisions of R602.10 show or provide a
braced wall panel at the wall facing the stairs, this will create a complete
braced wall line.
c) If the above items cannot be provided or if the building does not
satisfy the conventional bracing provisions, then provide design
calculations from a licensed Engineer or Architect to show
compliance.
• PLUMBING
10. The fuel-fired water heater is shown installed in a bedroom/bathroom. Detail
compliance with CPC 504.1: 1) A direct vent style of water heater or 2) Specify
it is to be installed in a sealed enclosure with a listed, gasketed, self-closing, and
latchable door with a threshold.
11. Please update the plumbing notes on sheet A3.1 to reflect the following correct
information: Lavatories are limited to 1.5 GPM, and showerheads may not
exceed 2.0 GPM of flow. CPC Section 403 and 408.
Carlsbad 15-0478
02/19/2015
12. Please indicate if the fixtures and appliances: Toilet, sink, washer and dryer are
new or existing at this location.
a) If new dryer: detail the dryer exhaust duct design from the dryer to the
exterior. The maximum length is 14 feet with a maximum of two 90-degree
elbows or provide the manufacturer's duct length specification description
on the plans: Include the dryer specifications (manufacturer, model, and
fuel type) as well as the duct description (size and type). CMC Section
504.3.
13. Specify on the plans whether the existing house was built before or after 1994.
For additions or improvements to a residence built before 1994, note on the
plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons
of water per flush, urinals that use more than one gallon of water per flush,
showerheads that have a flow capacity of more than 2.5 gallons of water per
minute, and interior faucets that emit more than 2.2 gallons of water per minute)
shall be replaced. Certification of compliance shall be given to the building
inspector prior to final permit approval. California SB407.
• RESIDENTIAL GREEN BUILDING STANDARDS
The California Building Standards Commission has adopted the Green Building
Standards Code which became effective January 1, 2011 and must be enforced
by the local building official. The following mandatory requirements for
residential construction must be included on your plans. CGC Section 1 0 1. 3.
The Standards apply to newly constructed residential buildings, along with
additions/alterations that increase the building's conditioned area, volume or
size. CGC Section 303.1.1. Provide a sheet on the plans labeled "Green
Building Code Requirements" and include the following notes as
applicable.
14. Indoor water use. Show compliance with the following table for new/replaced
fixtures, per CGC 4.303.1.
FIXTURE FLOW RA TES
FIXTURE TYPE MAXIMUM FLOW RA TE
Water closets 1.28 gallons/flush
~rinals 0.5 gallon/flush
Showerheads 2 gpm@80 psi
Lavatory faucets 1.5 gpm@ 60 psi 1
Kitchen faucets 1.8 gpm @ 60 psi
Metering faucets 0.25 gallons per cycle
I. Lavatory faucets shall not have a flow rate less than 0.8 gpm at 20 psi.
Carlsbad 15-0478
02/19/2015
15. Recycling. Note on the plans that a minimum of 50% of construction waste is to
be recycled. CGC 4.408.1.
16. Recycling. Note on the plans that the contractor shall submit a Construction
Waste Management Plan to the jurisdiction agency that regulates waste
management, per CGC 4.408.2.
17. Operation and maintenance manual. Note on the plans that the builder is to
provide an operation manual (containing information for maintaining appliances,
etc.) for the owner at the time of final inspection. CGC 4.410.1.
18. Pollutant control. Note on the plans that during construction, ends of duct
openings are to be sealed, and mechanical equipment is to be covered. CGC
4.504.1.
19. Pollutant control. Note on the plans that VOC's must comply with the
limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and
4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood
Products. CGC 4.504.2.
20. Interior moisture control. Note on the plans that concrete slabs will be
provided with a capillary break. CGC 4.505.2.1.
21. Interior moisture control. Note on the plans that the moisture content of wood
shall not exceed 19% before it is enclosed in construction. The moisture content
needs to be certified by one of 3 methods specified in Section 4.505.3. Building
materials with visible signs of water damage should not be used in construction.
The moisture content must be determined by the contractor by one of the
methods listed in CGC 4.505.3.
22. Indoor air quality. Note on the plans that bathroom fans shall be Energy Star
rated, vented directly to the outside and controlled by a humidistat. CGC
4.506.1.
23. Note on the plans that prior to final inspection the licensed contractor, architect
or engineer in responsible charge of the overall construction must provide to the
building department official written verification that all applicable provisions
from the Green Building Standards Code have been implemented as part of the
construction. CGC 102.3.
• ENERGY CONSERVATION
24. All hot water piping sized ¾" or larger is required to be insulated as follows: 1"
pipe size or less: 1" thick insulation; larger pipe sizes require 1 ½" thick insulation.
25. Below grade hot water piping is required to be installed in a waterproof and non-
crushable sleeve or casing that allows for replacement of both the piping and
insulation. ES 150.OU)
------~-----------------
Carlsbad 15-0478
02/19/2015
26. Residential energy lighting requirements: ES 150.0(k)
• In bathrooms. at least one fixture shall be high efficacy and all remaining
fixtures shall be high efficacy or be controlled by a vacancy sensor.
• Lighting installed in garages. laundry rooms. and utility rooms shall be high
efficacy and be controlled by vacancy sensors.
Please update the lighting notes on sheet A3.1 to reflect this correct information.
• MISCELLANEOUS
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes □ No □
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Kurt Culver (DA) at
EsGil Corporation. Thank you.
Carlsbad 15-0478
02/19/2015
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Kurt Culver (DA)
BUILDING ADDRESS: 1030 Magnolia Ave.
BUILDING OCCUPANCY:
PLAN CHECK NO.: 15-0478
DATE: 02/19/2015
BUILDING AREA
PORTION (Sq.Ft.)
Remodel 270
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code CB
Bldg. Permit Fee by Ordinance----• J
Plan Check Fee by Ordinance -----~
Valuation
Multiplier
City est
By Ordinance
Type of Review: 0 Complete Review
D Repetitive Fee
. ·..,.] Repeats
D Other
D Hourly
EsGII Fee
Reg. VALUE ($)
Mod.
35 000
35,000
$310.49!
$201.a2J
0 Structural Only
t------1,Hr.@ •
$173.871
Comments: In addition to the above fee, an additional fee of $43 is due (O.5 hours@
$86/hr.) for the CalGreen review.
Sheet 1 of 1
macvalue.doc +
----~-------------
<_(~f
~ CITY OF
CARLSBAD
PLANNING DIVISION
BUILDING PLAN CHECK
APPROVAL
P-29
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www .carlsbadca.eov
DATE: 2/17/15 PROJECT NAME: DEMO EXISTING UTILITY ROOM PROJECT ID:
PLAN CHECK NO: CB150478 SET#: ADDRESS: 1030 MAGNOLIA AV APN:
~ This plan check review is complete and has been APPROVED by the PLANNING
Division.
By: GINA RUIZ
A Final Inspection by the PLANNING Division is required □ Yes ~ No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check APPROVAL has been sent to: SAMFAM698@ATT.NET;
SMCINNIS7255@GMAIL.COM
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING ENGINEERING FIRE PREVENTION
760-602-4610 760-602-2750 760-602-4665
□ Chris Sexton □ Kathleen Lawrence □ Greg Ryan
760-602-4624 760-602-274i 760-602-4663
Chri~.Se~ton~s;;arl~bgg{;~.gQv Kl!lble11n.Ll!wr11nce!1!1cl!rlsQl!dca.gQv (l r11g2 Q!. Rxl! n!£!1cl! rl~ Qa dca. g2v
□ Gina Ruiz □ Linda Ontiveros □ Cindy Wong
760-602-4675 760-602-2773 760-602-4662
(lina.Rulz~carl~~l!dCl!,gov Linga.Qotiv11ros@cgrl~bl!!:!Cl!.gov !.xnlhig.WQng!1!1carlsQl!!:!ca.g2v
□ □ □ Dominic Fieri
760-602-4664
Domioi~.Fi~ti~~~rl~!;uut~g.gov
Remarks:
TURLEY
ENGINEERING
Structural Consulting -Engineering -Inspections
April 2, 2015
Sam Mcinnis
1030 Magnolia Ave.
Carlsbad, CA 92008
Re: Review of (N) to (E) slab dowel connection.
Project Address: 1030 Magnolia Ave., Carlsbad, CA 92008
Job #T14017
Mr. Mcinnis,
Per your request, I reviewed the current foundation detail 3 on D1.1 for the residential structure noted above. It is
our understanding that the existing slab edge has been underpinned 6" min and the new concrete slab will pour
up to and below the edge of the existing slab. The rebar dowel spacing may be increased to 48" o.c. between new
and existing slabs by inspection. Please proceed with the minor revision as the slab connection will be adequate
as currently underpinned and doweled.
if you have any further questions, please call.