HomeMy WebLinkAbout1050 AUTO CENTER CT; ; CB003676; PermitCity of Carlsbad
1835 Faraday Av Carlrbad, CA 92008
Building Inspection Request Line (760) 602-2725
04/27/200 1 Commercialllndustrial Permit Permit No: CB003676
Job Address: Permit Type: TI Sub Type: COMM
Parcel No: 2110800100 Lot #: 0 Status: ISSUED
Valuation: $40,000.00 Construction Type: NEW Applied: 10/02/2000
Occupancy Group: Reference #: Entered By: RMA Project Title: SPRINT PCS ANTENNA SITE Plan Approved: 11/09/2000 Issued: 04/27/2001
1050 AUTO CENTER CT CBAD
Inspect Area:
~ :/ SEPARATE PROPERTY TRUST 03-25-99 , ,. , . ., ,,
Applicant:
,. ,' .,,~
LARRY WHARTON
.. ., ,,.. . .. . :, , . _.,/ :, ;, . , ,. .,,
~ .;,.+: . ~ ~ I
Total Fees:
Plan Check $220.56 Me@ Fee $0.00
" '.:#'; $0.00 Plan Check Disco$@: $0.00 CFD Payoff Fee
$8.40. PFF
.. $0.00 PFF (CFD Fund)
Strong Motion Fee.'. ,
LFM Fee
Bridge Fee
BTD #2 Fee
$0.00
$20.00 Renewal Fee 1 $0.00 PLUMBING TOTAL
$0.00
Add'l Renewal Fee ' ' $0.00 ELECTRICAL TOTAL '.
$0.00 Other Building Fee ' ' $0.00 TOTAL
$0.00
Pot. Water Con. Fee '. $0.00 e'F&:
$0.00 Meter Size
Add'l Pot. Water Con. Fee Recl. Water Con. Fee $0.00 Additional Fees: $0.00
TOTAL PERMtf Pm $588.29
Add'l Plan Check F&; ' .' :': $0.00 SDCWA Fee ,, ,. : 1, $0.00 ,,
' '
,,
',., $0.00 Loen@ Tax Park Fee ,.
~' .. :;,' $0.00
$0.00
,, ,., ,
.. BTD #3 Fee $0.00 ., ,. ., ,,
,. w.00' RedevParkirylFee: . ,
,,
I FINAL APPROVAL
Inspector: .e'&&%& Date: G-/s.q/ Clearance: I
NOTICE: Please take NOTICE hat aWmval of your
rem to 85 'fe%xactans.' Yw have 90 day$ from he dab this prml was issued to pm$st imposibbo ofhese fembxdms. If yw pm$st U~em, you NElt follow me prdeot procedures sei forth in Govemmsnt Cade Secbbn 66020(a). and file the pmkt and any dher required infwmatlcm with the Cly Manager for
pmxnshg in adam with Cadstud Municipal Code Wbn 3.32.030. Failure to Umely follow that pdure will bar any subsequent legal actsn to W, review. sataside, voa, wannuitheir Impilian.
Yware herebyFURTHERNOTlFlED~atywr$httopmtest(he~ledfeeslex~mMXSNOTAPPLYtowater~nd~rmnnedi~(eas~nd~~
changes, m planning. zoning, grading or oher similar appllmlbn processing or service fees h mnm !MI hii poiecr NOR WES IT APPLY to any feaslaxacfions of which you have previouslv been gl
imludes he 'Imposilon' of&. dedmhs, raservatlons, or other exactions hbr collectively
PERMIT APPLICATION TmMc SD 126 CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ONLY
PLAN CHECK NO. a fl
EST. VAL.
Plan Ck. Deposit
Validated By
Date
1 '3 Bno T/
Address linciuds BldgISuite XI
Legal Description Lot NO. Subdivision NamelNumbsr Unit No. Phase No. Total X of units
Business Name (at this address)
Proposed Use BUC Asrerror's Parcel I Existing Use
Description of Work sa. FT. #of Stories
21 1- Q 8ii - / (
.51
Name Address City StatslZip Telephone X FIX X
gB#E.:B
(Sac. 7031.5 Business and Rofessionr Code: Any City or County which requires a permit to construct. alter, improve, demolish or repair any structure, prior to its
issuan~e, also requires the *ppiicmt for such perm* to fila 8 signed natsmsnt that he is licensed pursuant to the provisions at the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Rofessionr Codel or that he is exempt therefrom, and the bsliis for the alleged
exemption' Any violation of Section 7031.5 by any applicant for a permit subjecls the applicant to a civil penalty of not mora than five hundred dollars ld5001l.
Name Address City C-l fA. _- XNL. 10x7 ~~~PFJLI~ l+w 4 (nuNrnX StatslZip h . 9Ub( 114-99 8- 894,' e$ ,~
/
state License I 7 \ License Cisu utva*k*r.ulmnn 8
Designer Name Address City Statelzip Telephone
smte Llcs".. I
Worterr' CornpsMstion D~iamtiOn: I hereDy sffirm under penalty of perwry one of Ins following decidielions:
, .-
0 of the work for which this permit is issued.
0 issued. My worker's compensation insuranca carrier and poiicy number am:
,-Galnm mbh ONr ~Mffi,dkm L SU.
i have and will maintain a certificate of consent to self-ins1110 for workers' compensation 89 provided by Section 3700 Of the Labor Code. for the perfoimance
I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance Of the work for which this permk io
Expimhm Date $/&/!Cl I
CERTIFiCATE OF EXEMPTION: I Certify that in the performance of the work tor which this permit is issued, i shall not Bmpioy any person in any manner so a$
an employer to edmhd pnaklas and civil fines up to one hundred
powCvN0. Uk 00 7L03b m3
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS Id1001 OR LESS1
0 to kcoms subject to the Workers' Companration Laws of California.
WARNINO: Failurn to S~EYI. worked compnution wvnage Is unlawful. nnd
thousand dollars ~1100,000l. in ddition to the con of compen.atlon, damag. In Ssclion 3706 D attwnayh fees.
[7 i, as owner of the property or my empioyees with wages as their soie compensation, will do the work and the str~~t~re is not intended or offered far de
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner Of property who builds or improves thereon, and who do-
such work himself or through his own empioyees, provided that such improvements are not intended or Offered for sale. if, however, the building or improvement io
soid within one year of completion, the owner-builder will have the burden of proving that ha did not build of improve for the purpose Of salel.
0 I, as owner of the property. am exclusively contracting with licensed COntIactors to ~on~tru~t the project (Ssc. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner at property who builds or improves thereon, and contracts for such projects with ~ontractor(sl licensed
pursuant to the Contractor's License Law).
[7
1.
2.
3.
4.
number I ~ontra~tors iicanss number):
5.
of work):
i am exempt under Section
I personally pian to provide the major labor and materials for CDnnrYction of the proposed propew improvement. 0 YES UNO
i (have I have nml signed an application far a building permit for the propmod work.
i have contracted With the foilowing person (firm) to provide the proposed Constwction lineiuda name I address I phone number I ~ontnlctors license number):
i plan to provide portions of the work, but i haw hired the foilawing person to coordinate. Supervise and provide the major work (include name I address I phone
I wiii provide some of the Work, but i have contracted lhirsdl thn foilowing perrons to provide the work indicnted (include name I address I phone number I type
Business and Professions Coda for this reason:
PROPERTY OWNER SlGhATURE DATE
Is the applicant or future building DCCUP~~ required IO Submit a business pian, acuteiy hazardous matsriab registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Pisslay-Tanner Hazardow Substance Account Act7 0 YES 0 NO
1s the applicant or future building OCCUP~R required to obtain a permit from tha air pollution control dinrict or air quality management district? YES [7 NO
is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO
IF ANY OF THE ANSWERS ARE YES. A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUW UNLESS THE APPLICANT HAS MET OR IS MEETING THE REOUIREMENTS DF THE OFFICE OF EMERGENCY SERVICES AN0 THE AIR POLLUTION CONTROL DISTRICT.
I certify that I have read the application and state that the above information is Correct and that the information on the plans is ICCU~LO. I agree to compiy with aIi
City ordinances and State iaws ralating to building Construclion. i hereby authorize representativs of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purpos~s. I ALSO AGREE TO SAVE. INDEMNIFY AND KEEP HARMLESS THE CiTY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS. COSTS AND EXPENSES WHiCH MAY IN ANY WAY ACCRUE AGAINST SAID CiTY IN CONSEWENCE OF THE GRANTING OF THIS PERMIT.
OSHA An OSHA permit is required for eXCwatiOnS Ov0r 50" deep and demolition or Construction Of structures over 3 stories in height.
EXPIRATION: Every permit issuec by the building Official under the provisions of lhis cods shaii expire by limitation and become null and void if the building or work
authorized by such permit is no1 commenced within 180 d rk authorized by such permit is suspended or abandoned
at any lime aner the work is commenced for a period of 1
APPLICANT'S SiGNATURE 7 DATE /o-z+ 0
.. City of Carlsbad Bldg Inspection Request
For: 0611 412001
Permit# CB003676
Title: SPRINT PCS ANTENNA SITE
Description:
Type: TI sub TYPE: comm
Job Address:
Location:
1050 AUTO CENTER CT
Suite: Lot 0
APPLICANT LARRY WHARTON
Owner:
Remarks: HAD A MAN AT JOB ALL DAY ON TUES.
Inspector Assignment: GG
Phone: 7143058759
Inspector:
Total Time: Requested By: NA
CD Description Act Comments
Entered By: CHRISTINE
39 Final Electrical
Associated PCRs
InsDection History
Date Description Act lnsp Comments
05/03/2001 14 Frame/Steel/BolUng/ldlng AP GG
EKi - Corporation
DATE: November 7,2000
JURISDICTION: CARLSBAD
PLAN CHECK NO.: 00-3676 SET: 11
PROJECT ADDRESS: 1050 AUTO CENTER COURT
PROJECT NAME: ANTENNA & EQUIPMENT
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
The check list transmitted herewith is for your information. The plans are being held at Esgil
0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
and should be corrected and resubmitted for a complete recheck.
Corporation until corrected plans are submitted for recheck.
contact person.
0 The applicant's copy of the check list has been sent to:
0 Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Date contacted: I I / p/03 (by: ) Fax #:
, Person contacted: Lany Wharton Telephone #: (619) 203-1773
Mail Telephone v Fax In Person 0 REMARKS:
By: Kurt Culver Enclosures:
Esgil Corporation 0 GA 0 MB 0 EJ 0 PC lot03 (morntl.dot
9320 Chesapeake Drive, Suite 208 San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
- EsGil - Corporation
~
ln Partnership with ~ouemmnt for BuiGting Safety
DATE: OCT. 05,2000
JURISDICTION: CARLSBAD
, PLAN CHECK NO.: 00-3676
0 PLAN REVIEWER
0 FILE
SET: I
PROJECT ADDRESS: 1050 AUTO CENTER COURT
PROJECT NAME: ANTENNA Be EQUIPMENT
0 The plans transmitted herewith have been corrected where necessary and substantially comply
[XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes
with the jurisdiction's building codes.
when minor deficiencies identified below are resolved and checked by building department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
0 The applicant's copy of the check list has been sent to:
contact person.
(XI Esgil Corporation staff did not advise the applicant that the plan check has been completed.
0 Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: 1 Fax #:
Mail Telephone Fax In Person 0 REMARKS:
By: AliSadre Enclosures:
GA 0 MB 0 EJ 0 PC 10103
Esgil Corporation
msmtl.doi
9320 Chesapeake Drive, Suite 208 4 Sm Diego, California 92123 4 (858) 560-1468 4 Fax (858) 560-1576
.. .
.I
PLANNING/ENGINEERING APPROVALS
..
mL ..
ADDITION MINOR (< $10,aoaao,
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. cfi(sC)3&7b Address 1050 hCJ3-iEFL GT
APN: d-\\-c€?D *\I
Planner Christer Westman Phone (760) 602-461 4
Type of Project & Use: -/A Net Project Density: W'& DU/AC
Zoning: f', -2 General Plak Facilities Management Zone: 3
CFD (inlout) #- Date of participation: Remaining net dev acres:=
Circle One
(For non-residential development: Type of land used created by
this permit: rme. )
Legend: Item Complete 0 Item Incomplete - Needs your action
Environmental Review Required:
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES NO TYPE
APPROVALIRESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
YES - NO - TYPE
-
Coastal Zone AssessmentlCompliance
Project site located in Coastal Zone? YES NO
CA Coastal Commission Authority? YES- NO
If California Coastal Commission Authority: Contact them at - 31 11 Camino Del Rio North, Suite
200. San Diego CA 92108-1725; (619) 521-8036
Determine status (Coastal Permit Required or Exempt):
If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log #:
-
Coastal Permit Determination Form already completed? YES- NO-
Follow-Up Actions:
1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum
Floor Plans).
2) Complete Coastal Permit Determination Log as needed.
H:\ADMIN\COUNTER\BldgPlnchkRevChklst
- 0 0 0 lnclusionary Housing Fee required: YES - NO
IEffective date of lnclusionary Housing Ordinance - May 21, 1993.1
Data Entry Completed? YES - NO -
IA/P/Ds, Activity Maintenance. enter CBX, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!)
Site Plan:
1 .) Provide a fully dimensional site plan drawn to scale. 0 0 0 Show: North arrow,
property lines, easements, existing and proposed structures, streets, existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines.
0 (7 2. Provide legal description of property and assessor's paicel number.
Zoning: 0 0 1. Setbacks:
Front: Required Shown
Required Shown Interior Side: Street Side: Required Shown
Rear: Required Shown
0 0 0 2. Accessory structure setbacks:
Required Shown Front: Interior Side: Required Shown
Street Side: Required Shown
Rear: Required Shown
Structure separation: Required Shown
Shown 0 0 0 3. Lot Coverage: Required
0 0 0 4. Height: Required Shown
0 0 0 5. Parking: Spaces Required Shown
Guest Spaces Required Shown
0 0 0 Additional Comments
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE ]O.'I)5/&
r
r
r !
ARCON
SlRUCNRAL ENGINEERS, INC.
STRUCTURAL CALCULATIONS
FOR
SPRINT PCS EQUIPMENT PLATFORM
TAMARACK
SD-126B
1050 AUTO CENTER COURT
CARLSBAD, CA
i- I
r
PREPARED FOR .
AL VAR ARCHITECTS, INC.
August 11, 2000
Job No. 200007.25
am3w 22421 Gilberto. Suite B * Rancho Santa Margarita, CA 92688 * (949) 713-7824 * Fax (949) 768-1761
PROJECT TAMARACK JOB No. 2oooO7.25
ITEM: DESIGN LOADS DATE El1 1/00
SD-1266 BY: H. MONTOYA ARCON
mmRN ENGINEERS. IM. PAGE I OF 14
!
r
-
DESIGN LOADS:
1R" PLYWOOD
2x14 @ 12"
3.00 PSF.
1.50 PSF.
5.20 PSF.
INSUI~TION 1.00 PSF
MISCELLANEOUS 1.50 PSF. SUSP.SYSTEM 1.80 PSF.
KbOF DEAD LOAD 14.00 PSk. ~~~. - ROOF LIVE LOAD: 20.00 PSF.
FLAT ROCWBTAL LOAD: 34.00 PSF. (ADD 2.0 PSF. FOR BMS.)
ARFA PLATFORM
3.17~ 18.51 58.65 sq.fI
EQUIPMENT WE IGHTS
OUTDOOR FLWENT 1187.00 PSF
OUTDOOR FLEXENT 1187.00 PSF.
OUTDOOR FLEXENT 1187.00 PSF.
BAlTERY CABINET 2827.00 PSF.
EATERY CABINET 2827.00 PSF POWER CABINET 1747.00 PSF.
bEAD LOAD: 10962.00 PSF.
EQUIPMENT WEIGHT 187.00 PSF.
\
2
Z W >
/
r
PROJECT TAMARACK JOB No. 2oooO7.25
ITEM: FRAMING DESIGN DATE: El1 1/00
SD - 1268 BY: H. MONTOYA ARCON
STRUCTURAL EN~INEERS. INC. PAGE 4 OF 14
Fb= 675.00 Psi. D.L./ID.L.+L.L.)= 0.41
Fv=
E=
W=
Wa=
Wb=
wc=
Wd=
Pe=
95.00 Psi.
1600.00 Ksi. At=
34.00 Lbs./Ft.
0.00 Lbs./Ft.
0.00 Lbs./Ft.
0.00 Lbs./Ft.
0.00 Lbs./Ft.
0.00 Lbs.
0 Sq.Ft. 4 r= 0.00
L= 27.50 Ft.
a= 0.00 Ft.
b= 0.00 Ft.
C= 0.00 Ft.
d= 0.00 Ft.
e= 0.00 Ft.
Pf= 0.00 Lbs. f= 0.00 Ft. 1-
3~~192.5 Cf= 0.90
Pg= 0.00 Lbs. 9= 0.00 Ft.
ML= 0.00 LbS.-Ft. MR= 0.00 LbS.-Ft. + Cd= 1.25
RL= 467.50 Lbs. RR= 467.50 Lbs. CL= 215* Cr= 1.15
(+)Mmax.= 3214.1 LbS.-Ft.
V= 467.5 Lbs.
dm= 11.67 "
dv= 3.94 w= 34.00 #r
dy= 11.67 " (+/-)
Rduired d= 11.67 'I pb
Dtl= U 240
DII= U 360
--+ dv= 3.85
USE: 2x 14 D.F.#2 Oqk!! -
BEAM: BM-ItERJIp.Try 2 x D.F.#2 &. 12''
Fb= 875.00 Psi. D.L./(D.L.+L.L.)= 0.41
FF 95.00 Psi.
E= 1600.00 Ksi. At= 0 Sq.Ft. __* I= 0.00
i
W=
Wa=
Wb=
wc=
Wd=
Pe=
Pf=
ML=
Pg=
14.00 Lbs./Ft.
20.00 Lbs./Ft.
187.00 Lbs./Ft.
0.00 Lbs./Ft.
0.00 Lbs./Ft.
0.00 Lbs.
0.00 Lbs.
0.00 Lbs.
0.00 LbS.-Ft.
L= 27.50 Ft.
a= 24.33 Ft.
b= 3.17 Ft.
C= 0.00 Ft.
d= 0.00 Ft.
e= 0.00 Ft.
f= 0.00 Ft.
9= 0.00 Ft.
MR= 0.00 LbS.-Ft.
RL= 498.01 Lbs. RR= 966.36 Lbs.
(+)Mrnax.= 3633.6 LbS.-Ft.
V= 966.4 Lbs.
Dil= U
DII= U
dm= 12.44 'I
dv= 8.14 w= 201.00 #f --+ dv=
dv= 12.16 " [+/-)
Cd = 1.25
Cf = 0.90
Cr = 1.15
240
360
7.13 I'
Required d= ' 12.44 ______, USE: - - 2x 14 D.F.#2 I
-
/A ARCON ENGINEERS ITEM: FUM I rcllf.
CORPORATION
r I
6~a-3 r
r
r
r
r
!-
i
r
1
PROJECT SPRINT PCS - SD-126B JOB NO. 200007.25
TAMARACK BY: M. Mencera A STRUCTURAL ENQINEEM. INC. ITEM: FRAMlNGDESlGN DATE: 6/11100
PAGE6 OF 14
r wQm% 4w
BEAM: GLB-3 Try 5.125 x G.L.B.
FV= 165.00 Psi.
E= 1800.00 Ksi. At= 956 Sq.Ft. r= 0.40
1 Fb= 2400.00 Psi. D.L./(D.L.+L.L.)= 0.41 a
mi*Tmmritm 1 -a- j, I.. 6 4
Wa= W= 1098.00 -583.00 Lbs./Ft. Lbs./Ft. a= L= 25.50 2.75 Ft. Ft. cm
Wb= -583.00 LbS./Ft. b= 4.25 Ft. , -e*
Wd= 0.00 Lbs./Ft. d= 0.00 Ft. RL .. wc= 0.00 Lbs./Ft. C= 0.00 Ft.
Pe= 0.00 Lbs. e= 0.00 Ft.
Pf= 0.00 Lbs. f= 0.00 Ft.
Pg= 0.0 Lbs. 9= 0.00 Ft.
ML= 0.0 LbS.-Ft. MR= 0.0 LbS.-Ft. Cd = 1.25
1'
RL= 12276.22 Lbs. RR= 11641.78 Lbs
(+)Mmax.= 85512.0 LbS.-Ft
V= 12276.2 Lbs.
~~
Cv= 0.93
Dtl= u 180
DII= U 360
dm= 20.78 "
dv= 17.42 w= 515.00 W +dv= 16.42 I'
Required d= 20.83 " ,-. USE: 5.125 x 21.0 G.L.B.
dY= 20.83 " (+/-)
with 0.86 In. camber
r E 1098- 515'- 503 dc/ I
.
....................
I ........................
r
..... a,.. ................. ' 1 .............. ! im i .... ;. ............... i
b .
.......
r
r- i 1
i-
& E 0.T.M. = (3'+ 1') = d3SkSd'
r
r
r
r
r r
r
r
-
r L
r
r
!- !
r
r I
r I i
r
i I
r 1
r
r i
r i
i
r L
r
r i
7
c
r
r
r
r
r 1
r I
r
Car -66 fp -- I Y.C6x I
3
r
r 1
r
I
r
r
r
-1 6'- \\I'
-. 1
I
r
r
r I
r PROJECT swim Pc s JOBNO. ZOOS07
TALAAWK ps DATE
- -
ITEM,jT;I Am CORPORATION ARCON ENGINEERS PAGE OF
-
I
r r
r
r
r
r r
r
r r
i-
r \
r : I
i-
f r
2
r
r [
r
c
r
r
c
r
PROJECT NUMBER UOO1-101-001
DAT&: octobv 12, #w)o
STRUCTURAL CAU"S
for TAMARACKANTENNAENCLOSURE SPlU-00393M (SD35XC126B)
at
CARJABAD, CALIFORNU
for
STEALTHNETwoRKTEc"oLoGIES
BY:
FOR
ROGER T. kWORTH, P.E., %E
MANAGING ENGINEER
LR NEISON CONSULTING ENGINEERS, LLC. 51 Wd 9OOO South
Sandy, UT 84070
(801) 565-8580
(801) 565-9340
r
I
f
I
r
r
JOB NO. UOO1-101-001
DATE 10/12/00
IQJECT: Tamarack SHEET I OF
JBJECT: DESIGNED WLH CHECKED
IBERGLASS REINFORCED PLASTIC fFRQ
1.
2.
3. Th8hbricstorandoontrachxshpH~pacllulicna~topmbsctthe~PU~
All stnmtunl ahapahall be Stealth FRP SerieD 1525, pmducsd using the pllbusiar pmarsc.
AH cutedpa and Mahall be &with a resin mmpstiblewiththe main mabix uead htb abwtural
hpe.
etructwal shppg from sbuse to prevent braalmge. nbks. gouges. crte. during fakication. hendline. and
inotsIation.
struoaual shppsr Dhpn bef&Wated and s898mbkdae indicstsd on the
FRP tcJla and nutem betightmdto snw tghtand tumed an addml lntum and lookedwilh epoxy.
4.
5.
drswings.
TRUCTURALSTEEL
1.
2.
3.
A0 slndutd otsel q&a and pktes ahaH be par ASTM A36.
All etructwat asel tubes ahaU be pw ASTM A5oa grade 8.
All anchor bdb ahall be per ASTM A307, u.n.0. Stml to stsd cmm tcJla ahall be pr
ASTM A325N, uno.
4. All wading shsll be partormed wilh EmXX bw hydwn in ansppmMdfabkdm w.
r
r
r
r
r
r
r
r
r
r
r
r
i
r 1
r i
r 1
L r
r r
r
U@- /D 1 - oq
. I
c
U
I
~
1 0 4
1
Z -
- . . . - . . - . -. . . .. . . ..^_. .... ^...a, I..-.*.-.." z.1 nn.-.. ",,, nnn7 71 trrn
t
c i
r i
r
r 1
t- I
r
DATE /ff//4-
PROJECT 7TMnrUr;bc SHEET - 4 OF
SUBJECT DESIGNED CHECKED
'4"b A325N BOLTS
wX'4"xl0n BASE PLATE
TUBE STEEL COL D€sb5td bmN5
R= 500 Ib I 1 V= 100 16 &--+ 10' TYP. w.
SECTION A-A
DETAIL REFERENCE: ST602
r PROJECT %MA- SHEET - 5 OF
r SUBJECT DESIGNED CHECKED
r
r
r
r
r r r r
r
r
r
r
r
r
WE OUTRIGGER (SEE PLAN)
DETAIL REFERENCE: 88601
f t
c
c
j
r-
i
r I i
JOB NO. UWI-101-001
DATE: 10/12/00
ROJECT Tamarack SHEET 6 OF
iUBJECT DESIGNED WLH CHECKED
997 UBC WIND PRESSURES
ASIC WIND SPEED: m,
XPOSURE: c .. . . . cq =
k= .. .. . .. qs= 12.8
RESSURE = C.*Cq*qs*lw
Cq = 1.3 FOR STRUCTURES 40' TALL
Cq = 1.4 FOR STRUCTURES > 40' TALL
(USE WIND PRESSURE FOR XY STRUCTURE)
997 UBC SEISMIC LOADS
= [(GWR'TPW = %.On
fw = [(2.5*Ca+Rw E 0.660
f,=o.ll~*l=w= 0.083
;d.miczone: C" =
;dl Pmfik. C. =
!: T= " (n):
b. '1.
I;
I.:
'ANEL EL FRAME DEAD LOAD = 4 pef
4 pf)*(O.484) = 1.88 pef => WIND CONTROLS
w
w (CONTROLS)
w
1.02
0.51
0.08
Vl1.4 = 0.484 UI
i
r
I- 1
7
L
r
I
r
r
i
r
r
r
r
r
r
r :
r
r r
r
r r
JOB NO. UOOI-101-001
DATE 10/12/00
PROJECT Tamarack SHEET 7 OF
SUBJECT DESIGNED WLH CHECKED I
srh II STANDARD TUBE STEEL SCREEN WALL COLUMN
DESIGN REACTIONS
VdcA Raactkm (lb) = t 67s
BaecMm?=nt(i?-lb)= 1 2,279
HorbahrlR&(ion(Ib)= I 883
Wo= I 116
%Ea (m = 0.m O.K. nppmx M. (in)= I 0.31 O.K(Bgladonl%m..jaPmdion)
TYPICAL FRP ANGLE AT TOP AND BOTTOM OF SCREEN (STEALTHSKIN PANELS)
10,oca O.K.
CONNECTION OF SCREEN (STEALTHSKIN PANELS) TO FRP ANGLE
W (livn) = 66
Max.BOltSpsoing= 43.0 h. O.C.
CONNECTION OF FRP ANGLE TO COLUMNSlOUTRlGGERS
Rsacfion (lb) = 346.5
#of EdIa Raq. = 1 .o
r
JOB NO. &/-/d/-m/
DATE /@z/- r
r
I r
r r
r
f
PROJECT 7Zi~a SHEET g OF
SUBJECT DESIGNED L@ CHECKED
.... ~ ............ - ..................... .......... .,.. - ,.,. . ,, .," ,,,,, ,,, ,. ,," ". ,"
., ., .. -7- ? .p. ... ,W%l 5.k , L%*3?c ,,
,. . . ,. ... .. ,.
.,
.... R ...
IY'
p= &@IF CM') &.=: YGZ ib ' I
,., ,."flH. z.:. .YS?,~!!.37Q ....... ." ............... ....................... .......I. .I ...............
'~t~~ =, j.iu ;n) ,. ... ., - 7-3 ax3r v, Cs= wchq
., + o.cr. .,,
.,.
.I '. ,, .
.. , .. ,, . ,.
, ,,, , , . , .. , . , ............................................ ~ ..................................................
., '. . ............. ,,
....
, Be-fbG
,, .. *&+. 'y(;L 16
, ,. , ..
, , van = &/@&)'+*3 h=, 100 16. , I .. ........................ ............ ... ...... ..... ,- ....
I,
,. ,. .. ,.
. ,.
..
, , . , . . , ,, ,, , , ",, .. ..... . , ,.. .............................
.,
,, , .. . ,,, ................................................. ,.,
,I, (I ,.. ,,
,. ,. I, , ,..
>. . ............ , ,., ,, . ,.. , , , . ,,. . , , , ...... ", .......................................................
..,
..
., ..
... ....... .,, .. ...............
,I
,,
UTAH 51 West 9000 South Sandy, UT 84070 801 1565-8580 FAX 801 I 565-9340
NEVADA 3035 Eost Potrick Lane, Suite 9 Las Vegos, NV 891 20 702 / 798-7978 FAX 702 1 451 -2296
r
JOB NO. UWI-101-001
DATE: 10112/00
PROJECT Tamarack SHEET 9 OF
SUBJECT DESIGNED WLH CHECKED
WELDED CONNECl" WI FILLET WELDS TREATED AS LINES
DESCRIPTION
MEMBER SIZE TS 3&lN
CONNECTION OF HORIZONTAL TO BASE PLATE
b OT r (in) = -(inA2) = 12.00
d (in) = q,-(id2)= 12.00
Lwald (in) = 1- (in"3.3) = 38.00
EqlaIimI: (nctMguQr gw)
cfor Torque (in) =
Straglncnose:
FORCES ON WELD GROUP
AXIAL (Ib) =
SHEARw (lb) =
SHEARn (lb) =
MOMENTw (ft-lb) =
MOMENT= (ft-lb) =
TORQUE (ft-lh) =
vu (Wn) = 44
Dm. 0.0 ekbennm
vM (Wn) =
v,, (Wn) =
v- (IMn) =
v- (Wm) =
v- (Iblll) =
v- (IMn) =
-&I$
41.87
0.00
12.50
0.00
0.00
0.00
r
r
c
r
r
r
r
r
r
r
r r r r r r r
r I
r 1
LR. NELSON CONSULTINO ENQINEERS
51 WEST 9000 SOUTH SUITE 2
SANDY, UT 84070
(801) 665-6580
umi-ioim. Tltle : Tamarack
Dagnr: WLH 0.tC: Dcrrlption:
e-. Sm?T /o M/O ~ SllR. (801) 585 9340 fax
R." 51- UmaamasO W6I 3 2M.rloDo W ID) 4- MRUV. c hlhbmlrt. bIWt-fD1~l~~kem-c Steel Column Base Plate
Description Base plate for horizontals
License Detail wysiwyg://3/http://www2.cslb.ca.gov ... ibrary/CSLB+B~ok/License+Detail,DML
CALCORW COWIWCTORS STATE LICENIUE BOARD
License Detail
Contractor License # 719304
I DISCLAIMER ~ ~~ ~~ A license SUNS check provides information taken from the CSLB license dam base. Before relying on this information, you should be aware of
the following limitations:
CSLB is prohibited by law from disclosing complaints until they are refmd for legal action.
Per B&P 7071.1 7, only construction related civil judgments known to the CSLB are disclosed.
Arbibations are not listed unless the conbactor fails to comply with the term of the arbitration.
Due to workload, then may bs relevant information that has not yet been entered onto the Board's license data base. I
Extract Date: April 27,2001 * * * BUSINESS INFORMATION * * *
JITNEY COMPANY INC
1057 EAST IMPERIAL HIGHWAY
#605
PLACENTIA, CA 92670
Business Phone Number: (714) 528-8813
Entity: Corporation
Issue Date: 02/26/1996 Expire Date: 02/28/2002
* * * LICENSE STATUS * * *
This license is current and active. All information below should be reviewed.
* * * CLASSIFICATIONS * * *
A GENERAL ENGINEERING CONTRACTOR B GENERAL BUILDING CONTRACTOR
C10 ELECTRICAL,
* * * CERTIFICATIONS * * *
HIC HOME IMPROVEMENT CERTIFICATION
* * * CONTRACTOR BONDING INFORMATION * * *
This license has bond number 9006398 in the amount of $7.500 with the bondine comDanv
AMERICAN CONTRACTORS INDEMNITY COMPANY.
Effective Date: 02/14/2000
* * * WORKERS COMPENSATION INFORMATION * * *
This license has workers compensation insurance with the FREMONT COMPENSATION
INSURANCE COMPANY. Policy Number: WN0076036003 Effective Date: 08/15/2000 Expire
Date: 08/15/2001
I of2 4/27/2001 320 PM
-- I-