HomeMy WebLinkAbout1050 GRAND AVE; ; CB012687; Permit10-18-2001
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Building Inspection Request Line (760) 602-2725
Pool Permit Permit No:CB012687
Job Address: 1050 GRAND AV CBAD
Permit Type: POOL Status: ISSUED
Parcel No: Lot #: 0 Applied: 08/14/2001
Valuation: $21,058.00 Construction Type: NEW Entered By: JM Reference #: Plan Approved: 10/18/2001 Issued: 10/18/2001
Project Title: GUNITE POOL ONLY - 643 SF
EXTENDED STAY AMERICA
Applicant:
MISSION POOLS OF ESCONDIDO INC
755 W GRAND AVENUE
ESCONDIDO, CA 92025
61 9-743-2605
inspect Area:
Owner:
Total Fees: $366.06 Total Payments To Date: $124.86 Balance Due: $241.20
Building Permit Add‘l Building Permit Fee
Plan Check Addl Plan Check Fee
Electrical Fee
Strong Motion Fee
Plumbing Fee
Renewal Fee Add‘l Renewal Fee Other Building Fee
Additional Fees
TOTAL PERMIT FEES
$192.09
$0.00 $124.86
$20.00 $0.00
$27.00 $2.1 1
$0.00
$0.00 $0.00
$0.00
$366.06 */ Date:
FINAL APPROVAL
Inspector: Clearance: ,-, , ,,
NOTICE: Piease take NOTICE that apprwai of your project includes the ‘Imposilon” of fees, dedications, reservatwns, or other exactions hereafter WiiectiVelY
referred to as ”lee%xactions.” You have 90 days from the date this perm# was issued to protest imposition of these feeslexadimns. if you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a). and file the protest and any other required information wR the City Manager lor
processing in accordance with Carisbad Municipal Code Section 3.32.W. Failure to lmeiy follow that procedure will bar any subsequent legal adiwn to attack,
review, set aside, void, or annul their imposition.
Yw are hereby FURTHER NOTIFIED that your ight to protest the specfied fees/exactmns DOES NOT APPLY to water and Sewer connection fees and CapactiY
changes, nor planning, zoning, grading or other similar appiicatwn prmssing M service fees in wnnection with this pro@ct. NOR DOES IT APPLY to any
feeslexactions of which vou have previousiv been given a NOTICE similar to this, or as to which the statute of iimitations has Previousiv othenvise expired.
" 1"- FOR OFFICE USE 0
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
7
0 I am exempt Under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for Construction of the proposed property improvement. 0 YES ON0
2. I (have I have not) signed an application for a building Permit for the proposed work.
3. I have contracted with the following p0160n (firm) to provide the proposed construction (include name I address I phone number I contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone
number I contractors license number):
~~
I Certify that I have read the application and state that the above information is correct and that the information on the plans io accurate. I agree to comply with all
property for inspection purposes. I ALSO AGREE TO SAVE. INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
City ordinances and State laws relating to building Construction. I hereby authorize rapresentatives of the Cit( of Carlrbad to entsr upon the sbw8 mentioned
JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA Permit is required for excavations over 50" deep and demolition or Construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Olficiai under the provisions of this Code shall expire by limitation and become null and void if the building or work
at any time alter the work is c on Building Code).
APPLICANT'S SIGNATURE DATE
authorized by such permit is not commenced within 180 days from the date of Such permit or if the building or work
WHITE: File YELLOW Applicant PINK: Finance
/
I City of Carlsbad Bldg Ins k.
For: 10/02/2002
Permit# CB012687 Inspector Assignment: PS
Title: EXTENDED STAY AMERICA
Description: GUNITE POOL ONLY - 643 SF
Type: POOL Sub Type:
Job Address: 1050 GRAND AV
Suite: Lot 0
Location:
APPLICANT MISSION POOLS OF ESCONDIDO INC
Owner:
Remarks:
Phone: 7607432605
Inspector: 5z
Total Time: Requested By: MICHELE
Entered By: CHRISTINE
CD Description
59 Final Pool e4 10 L ! ”
Associated PCRslCVs
Date
09/26/2002
09/25/2002
09/25/2002
09/25/2002
09/25/2002
07/01/2002
06/28/2002
05/01/2002
05/01/2002
05/01/2002
Description
lnswction History
55 Fence/Pre-Plaster
Act lnsp Comments
NS PS
55 FenceIPre-Plaster
55 FencdPre-Plaster
NS PS
55 Fence/Pre-Plaster
NS PS
NS PS
55 Fence/Pre-Plaster NS PS
53 ElectridConduiVWiring AP PS INSIDE POOL BLDG
53 ElectridConduiVWiring NS PS
51 Excav/Steel/Bonding/Fence AP PS
53 ElectridConduitMliring
52 Underground Plumbing AP PS
AP PS
~ City of Carlsbad
BUILDING PLANCHECK CHECKLIST
POOLS I
BUILDING PLANCHECK NUMBER: CB 0 1 ab %7
BUILDING ADDRESS:
PROJECT DESCRIPTION: Pool
ASSESSORS PARCEL NUMBER:
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans, information
andlor specifications provided in your submittal;
therefore, any changes to these items afler this date,
office to insure continued conformance with applicable
including field modifications, must be reviewed by this
codes. Please rev=lly all comments attached,
as failure to comd nth nstructlons In this reoort can
By:
ATTACHMENTS
Grading Permit Application
Grading Permit Checklist
Right-of-way Permit Application
Right-of-way Permit Submittal
Checklist and Information Sheet
DENIAL
Please see the attached report of deficiencies
or specifications for compliance with applicable
marked with OMake necessary corrections to plans
codes and standards. Submit corrected plans
andlor soecifications to this office for review.
By: Date:
By: Date:
By: Date:
ENGINEERING DEPT. CONTACT PERSON
NAME: Kathleen M. Farmer
ADDRESS: 1635 Faradav Avenue
Carlsbad, CA 92009
I ~ ~~
PHONE: (760) 602-2741
,
1635 Faraday Avenue * Carlsbad, CA 92008-7314 * (760) 602-2720 * FAX (760) 602-8562 @
BUILDING PLANCHECK CHECKLIST - POOLS
SITE PLAN
;NW 3RW
0 1. Provide a fully dimensioned site plan drawn to scale, Show:
6 A. North Arrow C. Property Lines
B. Existing & Proposed Structures D. Easements
0 2. Show on site plan:
A. Drainage Patterns D. Indicate what will happen with B. Existing 8 Proposed Slopes
C. Existing Topography E. Retaining Walls soil excavated from pool area
(location and height)
Note: If excavated soil is not to be removed from property but regraded on
site, show proposed elevations and slopes.
If any portion of retaining walls are over 4' in height, a separate permit is required.
/ Retaining Wall Permit CB Applied for Approved
A0 0 3. Include on title sheet:
A. Site Address
B. Assessor's Parcel Number
C. Legal Description
D. Grading Quantities Cut Fill ImporVExport F 0 4. Project does not comply with the following Engineering Conditions of approval
for Project No.
Conditions were complied with by: Date:
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for grading permit are found in Section 11.06.030
of the Municipal code.
0 0 0 5a. Inadequate information available on Site Plan to make a determination on
grading requirements. Include accurate grading quantities (cut, fill, import,
export).
0 0 0 5b. Grading Permit required. A separate grading plan prepared by a registered Civil
attached. Engineer must be submitted together with the completed application form
Note: The Grading Permit must be issued and rough grading approval
obtained prior to issuance of a Building Permit
Page 1 of 2
,ST/ 2NDJ 3RDJ
0 0 0 5c. A Grading Permit has been applied for:
PE2 DWG
Grading Inspector sign off by: Date:
0 0 0 5d. No Grading Permit required.
MISCELLANEOUS PERMITS
0 6. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-way and/or
private work adjacent tot he public Right-of-way.
A separate Right-of-way issued by the Engineering Department is required
for the following:
Please complete attached Right-of-way application form and return to the
Engineering Department together with the requirements on the attached Right-
of-Way checklist, at the time of resubmittal.
Right-of-way Permit and Pool Building Permit will be issued simultaneously.
0 0 0 7. Remarks
Page 2 of 2
PLANNING/ENGINEERINC APPROVALS
ADDRESS Gflwdh AUK
. -RESIDENTIAL
RESIDENTIAL ADDITION MINOR
( < $1 0,000.00)
TENANT IMPROVEMENT
PLAZA CAMINO 'REAL
CARLSBAU COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
ENGINEER DATE
!-
GEOTECHNICAL ENGINEERING e ENVIRONMENTAL ENGINEERING
CONSTRUCTION TESTING & INSPECTION
October 23,2001 KANo. 116-01063
Extended Stay America
Attn: Matt O’Shea
2525 Cherry Avenue, Suite 3 10
Signal Hill, CA 90806
RE: Compaction Testing - Parking Lot Subgrade
Extended Stay America
1050 tirand Avenue
Carlsbad, California
Dear Mr. O’Shea,
In accordance with your authorization, we have performed compaction testing at the above-referenced project,
The compaction testing was performed by our engineering technician.
Test results taken within the subgrade were at least 95% of the maximum dry density, as determined by the
ASTM 1557. The maximum depth of the subgrade tested was one foot. This testing does not preclude the
possibility that the soil or fill may be loosened by future construction activities.
Results are based on limited sampling of the subgrade within the parking lot areas. Neither continuous nor part-
time grading observations were performed for this project. Our firm does not guarantee earthwork construction,
nor does our work relieve the contractor of his responsibility to conform with the approved project plans and
specifications.
The tables on the following pages present the results of the density tests taken at the project site. The depths cited
are measured from rough grade.
If you have any questions or if we may be of further assistance, please do not hesitate to contact our office at
(909) 549-1188. .
Respectfully submitted, W& & ASSOCIATES, INC.
-~
Donald Carlisle
Testing & Inspection Division Manager
DC/RSS:cp
CC: Magnum Enterprises
City ofCarlsbsd
R. Sammy Salem, P.E.
Southern California Regional Manager
RCE No. 52762
226 North Sherman Avenue, Suite A Corona, California 92882 (909) 549-1 188 Fax: (909) 549-1 190
With Eleven Offices Serving The Western United States
?-
Proj. No. 116-01063
I. Laboratory Compaction Curve Data (ASTM D1557)
Soil Curve Max. Dry Optimum
Soil Description Classification No. Density (pcf) Moisture i
Medium Brown Silty Sand
Silty Sand
SM A 122.0 8.0
SM D 119.8 8.8
11. Field Density Tests
Test Curve Test Dry Moisture
No. No. Density Percent Compaction Required
Percent
Depth
Percent
Suhgrade
October 3,2001
1
2
3
4
5
6
7
8
9
IO
11
12
13
14
15
16
17
18
19
20
A
A
A
A
A
A
A
A
A
A
D
D
A
A
A
A
A
A
A
A
0.0-1.0'
0.0-1.0'
0.0-1.0'
0.0-1 .O'
0.0-1.0'
0.0-1.0'
0.0-1.0'
0.0-1.0'
0.0-1.0'
0.0-1.0'
0.0-1.0'
0.0-1.0'
0.0-1.0'
0.0-1.0'
0.0-1.0'
0.0-1.0'
0.0-1.0'
0.0-1.0'
0.0-1.0'
0.0-1.0'
118.3
119.2
119.4
118.7
120.5
117.0
118.1
118.3
116.0
116.4
115.4
114.8
119.1
118.8
120.5
120.0
119.9
119.7
118.3
117.2
Offices Seming The Western United States
Krazan & Associates, Inc.
6.9
6.6
7.1
7.8
7.4
6.7
7.1
7.0
7.5
6.7
8.4
8.0
7.6
8.2
8.5
8.4
8.9
8.8
7.7
8.4
97%
98%
98%
97%
99%
96%
97%
97%
95%
95%
96%
96%
98%
97%
99%
98%
98%
98%
97%
96%
95%
95%
95%
95%
95%
95%
95%
95%
95%
95%
95%
95%
95%
95%
95%
95%
95%
95%
95%
95%
04ip5/2001 12:45 FAX 8585351800 HOBBS GROUP LLC moo2
I CCMPAm I
i
. ..
. .-