Loading...
HomeMy WebLinkAbout1050 GRAND AVE; POOL RM; CB020286; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Building Inspection Request Line (760) 602-2725 04-05-2002 Commercialhdustrial Permit Permit No: CB020286 Job Address: Permit Type: 1050 GRAND AV CBAD COMMIND Parcel No: Valuation: $22,016.00 Occupancy Group: Construction Type: V1 Reference #: Applied: 01/29/2002 Project Title: EXTENDED STAY AMERICA-256 SF Plan Approved: 04/05/2002 POOL EQUIPMENT ROOM Issued: 04/05/2002 Sub Type: HOTEL Lot#: 0 Status: ISSUED Entered By: RMA Applicant: JUANVASQUEZ 4458 04/05/02 0002 01 $2 Inspect Area: Owner: CGF' 353 * 41 626 793-91 19 Total Fees: $483.27 Total Payments To Date: $129.86 Balance Due: $353.41 Building Permit Addl Building Permit Fee Plan Check $0.00 Addl Recl. Water Con. Fee $0.00 Addl Plan Check Fee $0.00 $0.00 Plan Check Discount SDCWA Fee $0.00 $0.00 Strong Motion Fee CFD Payoff Fee $0.00 $4.62 Park Fee PFF $0.00 LFM Fee $0.00 PFF (CFD Fund) $0.00 License Tax $0.00 Bridge Fee $0.00 $0.00 BTD #2 Fee $0.00 License Tax (CFD Fund) Traffic Impact Fee $0.00 BTD #3 Fee $0.00 Renewal Fee $0.00 Traffic Impact (CFD Fund) $0.00 Addl Renewal Fee $0.00 PLUMBING TOTAL $0.00 ELECTRICALTOTAL $77.00 Other Building Fee $35.00 $0.00 Pot. Water Con. Fee MECHANICAL TOTAL $37.00 $0.00 Master Drainage Fee Meter Size $0.00 Add'l Pot. Water Con. Fee Sewer Fee $0.00 $0.00 Redev Parking Fee $0.00 $199.79 Meter Size $129.86 Meter Fee Recl. Water Con. Fee $0.00 TOTAL PERMIT FEES Additional Fees $483.27 $0.00 - I oate: 4 NOTICE: Please lake NOT that approval of your projea includes the 'impdSiticaf of fees, dedications, reservations, or other exactions hereafter collectively referred to as "feaslexactmn 7 You have 90 days from the date this permit was issued to protest imposition of these feeslexactions. If you protest them, you must follow the Drotest I)roocBcIures set forth in Government Code Seclion ffiMMal, and file the Drotest and anv other required information with be Citv Manager for review, set aside, void, or annul their imposition. psi& in a&rdance with Carlsbad Munidpa Code Section 3.32.030.' Failure totirneiy foilow that p;ccedure will bar any subsequent legal action toatack, . . . -. .~ .. . I. .. .. . . . -. .~ ~ .-. . .. . I. .. .. Inspection List ~~~ ~ ~ Permit#: CB07.0286 Type: COMMIND HOTEL EXTENDED STAY AMERICA-256 SF POOL EQUIPMENT ROOM Date Inspection Item Inspector Act Comments 11/20/2002 89 Final Combo PS AP FINAL PER PAUL SMITH 04/15/2002 62 SteeVBond Beam PS AP 04/12/2002 62 SteeVBond Beam PS NR 04/11/2002 31 Underground/Conduit-Wirin PS AP UFER 04/10/2002 61 Footing PS AP ~~.~ ... -. .... .~~~ ~~~~~~~ Wednesday, November 20,2002 Page 1 of 1 City of Carlsbad Bldg Inspection Request For: 0411 012002 Permit# CB020286 Inspector Assignment: Title: EXTENDED STAY AMERICA-256 SF Description: POOL EQUIPMENT ROOM Type: COMMIND Sub Type: HOTEL Job Address: 1050 GRAND AV Suite: Lot 0 Location: APPLICANT JUAN VASQUEZ Owner: Remarks: Phone: 7149017742 Insoector: P? Total Time: Requested By: TONY Entered By: CHRISTINE CD Description Act Comments 61 Footing B PCR01260 ISSUED PCR01304 WITHDRAW PCR01307 ISSUED PCR01322 ISSUED PCR02033 ISSUED PCR02043 ISSUED PCR02068 ISSUED PCR02082 ISSUED PCR02091 ISSUED InsDection History Date Description Act lnsp Comments - FROT. : PHONE NO. : 7145933281 Qpr. 09 2002 06:57RM P2 Date: To: Proiect Name and Address: Tush Surveymg & Mappw Inc. Land, Construction, Topographic Surveys Standard Certification Letter For Line and Grade LINE AND GRADE CERTIFICATION : Site: In compliance with thc conditions ofthe Contract, this letter is to serve as certification that the Pool Room set for the referenced woiect confarm with the inEormation Drovided LICENSE NO. LS k.7z-S EXPIRATION DATE OF LICENSE: 9 '3 I - 04 p I have examined the lines and points establjshed as &mi above and find them in accordance with the requiremmts ofthc Contract Documents. 21062 Brookhvnt S-t, Suite 207, tiuntingwn Beach, CA 92646 Bur: 714-593-325llFax: 7145953281 E-mail: tsrninc&tenet - FRW. : PHONE NO. : 7145933281 Qpr. 09 2002 06:57RM P1 'lustin Smeymg & Mappug, Xnc Land, Construction, Topographic Surveys I I Standard Certification Letter For Lie and Grade Date: To: Proieot Name and Address: LINE AND GRADE CERTIFICATION : Site: In compliance with the conditions of the Contract, this Mer is to serve as certification that the Pool set for the refmnced project conform with thc information provided on the EXPIRATION DATE OF LICENSE: 9-3\-04 CONTRACTORS ACCEPTANCE: I have examined the lines and pints established as demibed above and find them in accordance with the requirements of the Contract Documents. SUF'ERTINI'BNDENT (POI Gonsrl Comaor) 21062 Brookhurst Street. Suite 207, Huntington Beach, CA 92646 Bus.: 714.593-3251/I?~x: 714-33-3281 E-mail: rsrninc@m.net .-GiiKrazan 8, Associates, ~nc. OSA FilelAppl. No. CEOTfCHNlCAl ENGINEERING ENVIRONMENTAL ENGINEERING OSHPO No. CONSTRUCTION TESTING AND INSPECTION Permit No. DATE -\@ -cfl& CONTRACTOR: E* PROJECT #: I I c, - oilll, ~3 I.O.R.: J PROJECT E, PRESENT AT SITE: xcx\ LOCATION: ( c+kL 0 COPIES TO KRAZAN PROJECT MANAGER Lx WEATHER (-JvP&~G TEMP >-'' EARTHWORK @ Performed compaction testing on the following: a Performed observation for the following: Description Lab Nolsl. Curve Sampled % Required Depth of Testing 0 Building Padfsl: 0 Paved Areafsl: Trenchbs): XQ\ \!vu* L&.%& @ ExcavationfsIlOthsr: 1- 5 C. 969 i' /J pc,,.,l ,<.<i ^. 'ha, The following tests <$,et required percent compaction: Tr?& \- 'i C1-h 4-q r -_ La. .z Pending lab tests 0 Phone results ASAP to: Phone: 0 Verbal results transmitted to: r$ NOTES DISCREPANCIES 0- % COMPLETE T"y knowledge. the above ybFi.Z in am SuperintwdentlRepresentative: h :01 I Location of tests 'dance with the approved plans, specifications, and regulatory requirements. 8 " 226 N. Sherman, Ste. A, Cma, CA 92882 1501 15th Street NW, #106, Auburn, WA 98002 0 (909) 549-1 18, (253) 939-250r 20714 State Route 305 N.E., Ste. 3C, Poulsh, WA 98370 (360) 598-2126 19501 144thAve. NE#'NOO, Wdinville, WA 98072 * (425) 485-5519 12816 N. E. 95th St., Ste. B-100. Vancouver, WA 98682 (360) 254-3200 P - EsGil Corporation ln Tartncrsfiip witli @vemmrnt for !BuiEiirg Safety DATE: 3/19/02 JURISDICTION: Carlsbad PLAN CHECK NO.: 02-286 0 PLAN REVIEWER 0 FILE SET: I1 PROJECT ADDRESS: 1050 Grand Ave. PROJECT NAME : Extended Stay America- Pool Equipment Building The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. 0 The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. 0 The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: 1 Fax #: Mail Telephone Fax In Person REMARKS: City to verify that the pool and related mechanical equipment is not a part of this plan approval, By: ChuckMenden pJ-+ all Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 311 1102 lrnsmU.dot - - EsGil Corporation Zn Tartnersfiip witK ~ovcrnmnt for BuiHingSafcty DATE: 3/5/02 JURISDICTION: Carlsbad 0 PLAN REVIEWER 0 FILE PLAN CHECK NO.: 02-286 SET I1 PROJECT ADDRESS: 1050 Grand Ave. PROJECT NAME : Extended Stay America- Pool Equipment Building 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. w The applicant's copy of the check list has been sent to: MCG Architecture 200 S. 10s Robles Ave., Suite 300, Pasadena, CA 91 101 0 Esgil Corporation staff did not advise the applicant that the plan check has been completed. w Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: MCG Architecture Telephone #: (626) 793-91 19 Date contacted: 31 b/UL (by: f+ 8 Fax #: (626) 796-9295 Mail /Telephone Fax4 In Person 0 REMARKS: By: Chuck Mendenhall Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 2/26/02 trnsrntl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad 02-286 3/5/02 NOTE: The items listed below refer to the item numbers from the previous list. These remaining items have not been adequately addressed. The notes in bold at the end of each item are to emphasize the remaining problem. 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commerciallindustrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: to the City of Carlsbad Building Department, Carlsbad, CA 92009, (760) 602-2721. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculationsheports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculatiodreports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Deliver all corrected sets of plans and calculationsheports directly NOTE: Plans that are submitted directly to EsGil Corporation only 3. Provide data on proposed hazardous material to be stored and used. UBC, Section 307 and UFC. No response 4. Clearly show types of hazardous material is being stored or used. Provide a list of the proposed hazardous materials as per the types in UBC, Tables 343, and 3-E. Provide the material safety data sheets (MSDS). No response 5. Clearly show the amounts of each type of hazardous material to be stored and in use. No response 6. Clearly show where in the buildings each type of hazardous material is being stored or used. No response 7. Specify on the plans the following information for the roof materials, per Section 106.3.3: No response Manufacturer's name. Product name/number. ICBO approval number, or equal. PLUMBING (1997 UNIFORM PLUMBING CODE) 8. Provide gas line calculations, showing pipe lengths and gas demands. UPC Section 1217.0 No response Carlsbad 02-286 3/5/02 9. Show that water heater is adequately braced to resist seismic forces. Provide two straps. One strap at top 1/3 of the tank and one strap at bottom 113 of the tank. UPC, Section 510.5 No response 11. Provide calculations to show that the 2” waste & drain line is adequate to accommodate the back feed from the pump as shown in note 7 on sheet SP2.1. It doesn’t appear that the 2” would be adequate to accommodate the pump flow. No response To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. EsGil Corporation Zn Tartncrsfiip witfi @vcrnment for !Buil;ingSnfcty DATE: 2/6/02 JURISDICTION: Carlsbad PLAN CHECK NO.: 02-286 SET: I 0 APPLICANT 0 FILE PROJECT ADDRESS: 1050 Grand Ave. PROJECT NAME: Extended Stay America, Pool Equipment Building 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. w The applicant's copy of the check list has been sent to: MCG Architecture 200 S. 10s Robles Ave., Suite 300, Pasadena, CA 91 101 0 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: MCG Architecture Telephone #: (626) 793-91 19 Date contacted: d b/O 2 (by:h,,) Fax #: (626) 796-9295 Mail hlephone Fax- In Person 0 REMARKS: By: Chuck Mendenhall Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 1/31/02 tmsrntl.dot 9320 Chesapeake Drive, Suite 208 San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 J Carlsbad 02-286 2/6/02 PLAN REVIEW CORRECTION LIST COMMERCIAL OCCUPANCY: F1 USE: Pool Equipment Bldg TYPE OF CONSTRUCTION: rrr N ACTUAL AREA: 256 ALLOWABLE FLOOR AREA: 12,000 STORIES: one HEIGHT: loft per UBC SPRINKLERS?: no OCCUPANT LOAD: 1 REMARKS: DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: ESGIL CORPORATION: 1/31/02 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Chuck Mendenhall COMPLETED: 2/6/02 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To Speed UP the recheck process, please note on this list (or a COPY) where each correction item has been addressed, i.e., plan sheet number. specification section. etc. Carlsbad 02-286 2/6/02 1. 2. 3. 4. 5. 6. 7. 0 8. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commerciallindustrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculationsheports directly to the City of Carlsbad Building Department, Carlsbad, CA 92009, (760) 602-2721. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculationsheports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Clearly note on the plans that the swimming pool construction is not a part of this plan. Also, revise the deferred submittal notes on sheet TI .I. See detail 8 on sheet TI .I. This deferred submittal should indicate deferral of the structural design and construction plans for the swimming pool not roof trusses. The pool is not a part of this permit application. Provide data on proposed hazardous material to be stored and used. UBC, Section 307 and UFC. Clearly show types of hazardous material is being stored or used. Provide a list of the proposed hazardous materials as per the types in UBC, Tables 3-D, and 3-E. Provide the material safety data sheets (MSDS). Clearly show the amounts of each type of hazardous material to be stored and in use. Clearly show where in the buildings each type of hazardous material is being stored or used. 2. Bring one corrected set of plans and calculationsheports to EsGil Specify on the plans the following information for the roof materials, per Section 106.3.3: Manufacturer's name. Product namelnumber. ICBO approval number, or equal. PLUMBING (1997 UNIFORM PLUMBING CODE) Provide gas line calculations, showing pipe lengths and gas demands. UPC Section 1217.0 Carlsbad 02-286 2/6/02 9. IO. 11. 12. Show that water heater is adequately braced to resist seismic forces. Provide two straps. One strap at top 1/3 of the tank and one strap at bottom 1/3 of the tank. UPC, Section 510.5 Show P & T valve on water heater and detail drain line route from P & T valve to the exterior. UPC Section 608.5 Provide calculations to show that the 2” waste & drain line is adequate to accommodate the back feed from the pump as shown in note 7 on sheet SP2.1. It doesn’t appear that the 2” would be adequate to accommodate the pump flow. MECHANICAL (1997 UNIFORM MECHANICAL CODE) Detail the pool water heater flue (vent) terminations as per UMC, Section 806. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 8581560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. Carlsbad 02-286 2/6/02 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 02-286 PREPARED BY: Chuck Mendenhall DATE: 2/6/02 BUILDING ADDRESS: 1050 Grand Ave. BUILDING OCCUPANCY: F1 TYPE OF CONSTRUCTION: I11 N VFl Valuation Mod. Multiplier VALUE ($) Reg. I I pool equip. bldg I 256 I City Est 22,016 I I I I I I I I I Air Conditioning Fire Sprinklers I I I I I TOTAL VALUE I 22,016 Jurisdiction Code Elda. Permit Fee bv Ordinance ! V I By Ordinance cb Plan Check Fee by Ordinance ~ I Type of Review: Ei 0 Structural Oniy Repeats 0 Repetitive F= 0 Other - Hourly 1 Hour* U Esgil Plan Review Fee - $199.791 Comments: Sheet 1 of 1 rnacvalue.doc PLANNING/ENGINEERING APPROVALS RESIDENTIAL RESIDENTIAL ADDITION MINOR ( < $10,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING ENGINEER DATE t ? Silotrrrl - Strrrcturd Ertgirreerirrg Currsrrltrrrrt 3333 Urea C(rrryorr lhtl, Strite 115, Diurrrorrrl Bur, CA 91 765 Tel: (909) 598-8218 F~Ix: (909) 598-8758 WAM Job: E% - CAW~B/+D Sheet: 1 tructural Engineering Consultants 333 Brea Canwn Rd. #I I5 wL HdSE. lond Bar, CA 91165 Numb. :(909)598-8218 Architect L ~ctural Engineering Consultants 3BrtaCanyonRd.#llS mond Bar, CA 91765 Number: PwL HodsE. .:(9091598-8218 Architect. c"-3" .. .