Loading...
HomeMy WebLinkAbout1060 AUTO CENTER CT; M; CB053234; Permit12-15-2005 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB053234 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group; Project Title: 1060 AUTO CENTER CT CBAD St: M Tl Sub Type: Lot#: $96,000.00 Construction Type: Reference #: ENTERPRISE RENT A CAR 3.000 SF IMPROVEMENT COMM 0 NEW Applicant: SAUNDERS CONSTRUCTION P O 890801 TEMECULA 92589 951-712-9977 Owner: Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check#: ISSUED 09/13/2005 MDP 12/15/2005 12/15/2005 Building Permit Add'l Building Permit Fee Plan Check Add'l Ptan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Red. Water Con. Fee $531.16 Meter Size $0.00 Add'l Reel. Water Con. Fee $345,25 Meter Fee $0.00 SDCWA Fee $0,00 CFD Payoff Fee $20.16 PFF (3105540) $0.00 PFF (4305540) $0.00 License Tax (3104193) $0.00 License Tax (4304193) $0.00 Traffic Impact Fee (3105541) $0.00 Traffic Impact Fee (4305541) $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Master Drainage Fee Sewer Fee $0.00 Redev Parking Fee $0.00 Additional Fees TOTAL PERMIT FEES $0.00 $0,00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $48.00 $35.00 $30.50 $0.00 $0.00 $0.00 $0.00 $1,010.07 Total Fees:$1,010.07 Total Payments To Date:$1,010.07 Balance Due:$0.00 DING PLANS V IN STORAGE ATTACHED Inspector: FINAL APPROVAL-?/}£//* /Date: *V // Q U Clearance: NOTICE: Please take NOTICE tharapproval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously beerLQiven a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION• iCITY OF CARLSBAD BUILDING DEPARTMENT1635 Faraday Ave., Carlsbad, CA 92008 0525601-3 0018 09/13/2005 001 15FOR OFFICE USE ONLYEST. VAL.PLAN CHECK _..^ O oOPlan Ck. Deposit *3^-£N-Validated ByDate LAfldress (include Bldg/Suite #)Legal DescriptionAssessor's Parcel #DescjjptjfiQ of Worfl -~ —Business NameLot No. Subdivision Name/NumberExisting Use/SO. FT. #of Stories (at this address)Unit No. Phase No.Proposed UseJ \ # of Bedfooms ^ ^Total # of units# of BathroomslSrl'™i§;l^|ii;HP^! Name Address City State/Zip Telephone #Fax # Name Address City State/Zip Telephone # ;'£•&/• pg.3.: e/t. Name Address City State/Zip Telephone (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant tp a civil penalty of not more than five hundred dollars [$500]). Name , Address —Z/O~7 / »r~ <— " >B-State License # s Js s (*& J J License Class ^^ City State/Zip Telephone **y C: " / O city Business License # (jUuh A I0sfy L-sA. f-1 f " - ' / f L-- Designer Name Address State License # City State/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: O I have end will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. fj I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) CJ^ CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as 'to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage ia unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition tp the cost of compensation, damages as provided for in Section 3706 of the Labor code. Interest and attorney's f«es. SIGNATURE fflfr ^^2*^^""""" DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason: n I. as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). rj I. as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). C] I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QNO 2. t (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): ^ ^ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): O PROPERTY OWNER SIGNATURE DATE NO Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that 1 have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit Is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period- of UK) davsJSection 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE DATE WHITE: File YELLOW; Applicant PINK: Finance CltyifCirlifcal Final Building Inspection Dept: Building Engineering Planning CMWD St Lit Plan Check #: Permit*: CB053234 Project Name: ENTERPRISE RENT A CAR 3,000 SF IMPROVEMENT Address: 1060 AUTO CENTER CT #M Contact Person: BRETT Phone: 9517129977 Sewer Dist: Water Dist: Lot: 03/09/2006 Permit Type: Tl Sub Type: COMM 0 Inspected /?-<<7 Inspected Bv: Inspected Bv: Comments: Date Inspected: Date Inspected: Date Inspected: WwIsf&t+ Approved: £, Approved: Approved: Disapproved: Disapproved: Disapproved: City of Carlsbad Bldg Inspection Request For: 03/10/2006 Permit# CB053234 Title: ENTERPRISE RENT A CAR Description: 3,000 SF IMPROVEMENT Inspector Assignment: PY Sub Type: COMM 1060 AUTO CENTER CT M Lot 0 Type: Tl Job Address: Suite: Location: APPLICANT SAUNDERS CONSTRUCTION Owner: Remarks: Phone: 9517129977 Inspector: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By: BRETT Entered By: KAREN Comment Comments/Notices/Hold Associated PCRs/CVs Original PC# Inspection History Date Description 02/28/2006 14 Frame/Steel/Bolting/Welding 02/28/2006 34 Rough Electric 02/28/2006 44 Rough/Ducts/Dampers 02/27/2006 14 Frame/Steel/Bolting/Welding 02/27/2006 34 Rough Electric 02/27/2006 35 Fixtures 02/21/2006 24 Rough^opout 02/17/2006 11 Ftg/Foundation/Piers 02/16/2006 17 Interior Lath/Drywall 02/16/2006 21 Underground/Under Floor 02/01/2006 34 Rough Electric 12/19/2005 14 Frame/Steel/Bolting/Welding 12/19/2005 21 Underground/Under Floor Act Insp Comments AP PY T-BAR AP PY AP PY NR PY NR PY NR PY AP PY EMR #5 AP PY slabs AP PY AP PY AP PY PA PY AP PY City of Carlsbad Bldg Inspection Request For: 03/09/2006 Permit# CB053234 Title: ENTERPRISE RENT A CAR Description: 3,000 SF IMPROVEMENT Inspector Assignment: PY Sub Type: COMM 1060 AUTO CENTER CT M Lot 0 Type: Tl Job Address: Suite: Location: APPLICANT SAUNDERS CONSTRUCTION Owner: Remarks: Phone: 9517129977 Inspector: Total Time:Requested By: BRETT CD 19 29 39 49 Description Final Structural Final Plumbing Final Electrical Final Mechanical Entered By: JANEAN Act Comment M I/ Comments/Notices/Hold Associated PCRs/CVs Original PC# Inspection History Date Description 02/28/2006 14 Frame/Steel/Bolting/Welding 02/28/2006 34 Rough Electric 02/28/2006 44 Rough/Ducts/Dampers 02/27/2006 14 Frame/Steel/Bolting/Welding 02/27/2006 34 Rough Electric 02/27/2006 35 Fixtures 02/21/2006 24 Rough/Topout 02/17/2006 11 Ftg/Foundation/Piers 02/16/2006 17 Interior Lath/Drywall 02/16/2006 21 Underground/Under Floor 02/01/2006 34 Rough Electric 12/19/2005 14 Frame/Steel/Bolting/Welding 12/19/2005 21 Underground/Under Floor Act AP AP AP NR NR NR AP AP AP AP AP PA AP Insp PY PY PY PY PY PY PY PY PY PY PY PY PY Comments T-BAR EMR#5 slabs CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE (760) 602-2700 1635 FARADAY AVENUE TIME LOCATION PERMIT NO. (fl- FOR INSPECTION FOR LL (760) 602-2725. RE-INSPECTION FEE DUE? 3MATION, CONTACT YES PHONE BUILDING INSPECTOR i CODE ENFORCEMENT OFFICER •Carl Schmidt Inspection Serviced Inc.DAY WEDNESDAY P.O..BOX 178403 San Diego, CA 92177-8403 (619) 855-9252 SPECIAL INSPECTION REPORT Project: ,£ Address: _1060 AUTO CENTER COURT SUITE M CARLSBAD CACity: Permit Number: CB053234.Plan File Number: Reinforcing Epoxy Number of Samples: ; TYPE OF OBSERVATIONS: Reinforced Concrete! Structural Masonry Field Welding Prestressed Concrete Shop Welding X Bolting Fireproofing _ Type: f TS, A £6 PLAT^ E71T-1 ELECTRODE Date: 3/1/06 DEPORT ON SITE FOR VISUAL INSPECTION OF WELDING AS PER APPROVED PLANS, DRAWINGS AND DU WELDING CODE. i : SCOPE OF WORK ANDWELD END CAP 3/A4. WELD 3X3X1/3 EA. 3X3X1/4X4" ANGLE BOLT; PLATES TO ENQ OF 4X8X3/8" TUBE STEEL BEAM AS PER DET. " ANGLE TO TOP OF 4X8X3/8" TUBE STEEL.AS PER DET. 1/A4 WELD SIX TABS TO TW0 EA. 4X4X1/4" TUBE STEEL COLUMNS AS PER DET. 2/A4 INSPECTED ANDN ACCEPTED FIT UP AND ^ELDING. : ^ ONE WELDER FCAW-G E71T-1 ELECTRODE. WORK INSPECTED CONFORMS^WITH APPROVED PLANS DUANE LORENZ^—; ^ 5249699-85 Ceftification : SD 963 AND SPECIFICATIONS UNLESS OTHERWISE NOTED TIME IN: O800 TIME OUT: 1200 General Contractor: SAUNDERS CONT. Authorized Job Site<6ont£ct Signature AddresstPO, BOX 890801 City: TEMECULA CA 92589 Phone: Carl Schmidt Inspection Servicks. Inc. fM^Box 178403 \ SanDiego,CA 92177-8403 \ (619)855-9252 SPECIAL INSPECTION REPORT Project: _ [ _ ; Address: 1060 AUTO CENTER COURT M Citv: CARLSBAD CA * Permit Number: CB053234 Plan File Number: TYPE OF OBSERVATIONS: Reinforcing Steel lijeinforced Concrete Structural Masonry Field Welding Epoxy X Prestressed Concrete Shop Welding Bolting Fireproofing _ Number of Samples: Materials/DesignMix/Psi;_ Date: 3/1/06 REPORT ON SITE FOR VISUAL INSPECTION OF EPpXY AS PJpR APPROVED PLANS, DRAWINGS. SC(pPEOFWORK WITNESSED EPOXY OF 26 5/8ITX7'' BOLTS WITH 5" MINIMUM EMBED. ALL HOLE WERE BRUSHED AND BLOWN CLEAN PRIOR TO PLACEMENT OF ICBO ER 5279 EPOXY AND BOLTS. W INSPECTED CONFORMS WITH APPROVED PLANS AND SPECIFICATIONS UNLESS OTHER WISE NOTED TIME IN: TIME OUT: Inspector (Print)Certification # Inspector's Signature Authorized Job Site Contact Signature General Contractor: SAUNDERS CONT. AddressrPO. BOX 890801 City: THMECULA CA 92589 Phone: -7'H I i I i i u\ li—. i f-\r-\—i i f\f\ r>n Carlsbad 05-3234 12/09/05 EsGil Corporation In Partners/tip witfi government for 'Suiting Saftty DATE: 12/09/05 Q APPLICANT^ JURISDICTION: Carlsbad U PLAN REVIEWER a FILE PLAN CHECK NO.: O5-3234 SET:H PROJECT ADDRESS: 1060 Auto Center Court PROJECT NAME: Enterprise Rent A Car Office & Car Wash XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. CH The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. CH Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Chuck Mendenhall Enclosures: Esgil Corporation D GA D MB D EJ D PC 12/05/05 trnsmtl.dot EsGil Corporation In {Partnership witft government for QuiCtfing Safety DATE: 9/23/05 a APPLICANT JURISDICTION: Carlsbad a PLAN REVIEWER Q FILE PLAN CHECK NO.: 05-3234 SET: I PROJECT ADDRESS: 1060 Auto Center Court PROJECT NAME: Enterprise Rent A Car Office & Car Wash TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. • The applicant's copy of the check list has been sent to: , Glenn Kennedy, Architect 4660 Calle Del Greco, Oceanside, CA 92056 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Glenn Kennedy (V«M) Telephone #: (760_ 643-1506 Date contacted: ?lzWo5" (by: {£~) Fax #: Mail ^ Telephone*^ Fax In Person REMARKS: By: Chuck Mendenhall Enclosures: Esgil Corporation D GA D MB D EJ D PC 9/15/05 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 4 Fax (858) 560-1576 Carlsbad O5-3234 9/23/05 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: O5-3234 JURISDICTION: Carlsbad OCCUPANCY: B, S3 USE: Car rental office and Car wash TYPE OF CONSTRUCTION: V N ACTUAL AREA: 2974 TI Only ALLOWABLE FLOOR AREA: no change STORIES: no change HEIGHT: no change SPRINKLERS?: Yes OCCUPANT LOAD: 34 REMARKS: DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: _ ESGIL CORPORATION: 9/15/05 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Chuck Mendenhall COMPLETED: 9/23/05 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot Carlsbad 05-3234 9/23/05 • Please make alt corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92009, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Provide a section view of the new interior one hour partition between the car wash and the office area. a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". b) Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load). c) Wall sheathing material and details of attachment (size and spacing of fasteners). d) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. 2. Provide ceiling framing for the hard lid ceiling above the rest room. 3. Specify lever-type hardware for passage doors on floors accessible to the disabled. Title 24. 4. In Groups B and S Occupancies, if the number of employees exceeds four, provide separate toilet facilities for men and women. If "the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan. Section 2902.3. 5. In areas where the occupant load is at least 30, two exits are required. See UBC. Table 10-A. Given the different use area especially the rental service area, the occupant load exceeds 30 and requires two exits. 6. Exits should have a minimum separation of one-half the maximum overall diagonal dimension of the building or area served. Section 1004.2.4. Carlsbad 05-3234 9/23/O5 • ELECTRICAL 7. Show or note on the plans that he light fixtures within the car wash are to be a min. of 12'-0" above the floor surface. NEC511-7(b). 8. Note on the sheet E-1 of the plans that the receptacles and other electrical equipment within the car wash are to be a min. of 18" above the floor or they must be rated for class I location (explosion proof). NEC 511-3(a). • MECHANICAL 9. Detail overflow (secondary) condensate discharge from air conditioning units that are in a ceiling space, to a readily observable location. (UMC Section 1105.12) 10. Provide mechanical ventilation within the car wash per UBC Section 1202.2.1. See Section 1202.6 for exception which must be approved by the Building Official. DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 ACCESSIBLE PARKING 11. Show that at least one accessible parking spaces shall be served by an access aisle >96" in width and designated as VAN ACCESSIBLE, per Section 1129B.4.2. 12. The words "NO PARKING" shall be painted on the ground within each loading and unloading access aisle (in white letters no less than 12" high and located so that it is visible to traffic enforcement officials). Section 1129B.4.2. 13. Ramps shall not encroach into any accessible parking space or the adjacent access aisle. Section 1129B.4.3. Show on the plans the location of the curb ramp for the disabled accessible parking. • DOORS 14. Show or note that ail hand-activated door opening hardware meets the following requirements, per Section 1133B.2.5.2: a) Latching, or locking, doors in a path of travel are operated with a single effort by lever type hardware, by panic bars, push-pull activating bars, or other hardware designed to provide passage without requiring the ability to grasp the opening hardware. b) Is to be centered >30" but S44" above floor. Carlsbad 05-3234 9'/23/O5 15. Note that the doorways leading to sanitary facilities shall be identified, per Section 1115B.5, as follows: a) An equilateral triangle 14" thick with edges 12" long and a vortex pointing upward at men's rest rooms. b) A circle !4" thick, 12" in diameter at women's rest rooms. c) A 12" diameter circle with a triangle superimposed on the circle and within the 12" diameter at unisex rest rooms. d) The required symbols shall be centered on the door at a height of 60". e) Braille signage shall also be located on the wall adjacent to the latch outside of the doorways leading to the sanitary facilities, per Section 1117B.5.7. * COUNTERS 16. The tops of tables and counters shall be 28" to 34" from the floor. The disabled accessible a section of counter is shown on the floor plan to be 36" high. Section 1122B.4. END OF REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. ,;•-.-*..:!: The jurisdiction has contracted with Esgil Corporation located at 9320 .: Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of; 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. Carlsbad O5-3234 9/23/05 JURISDICTION: Carlsbad VALUATION AND PLAN CHECK FEE PLAN CHECK NO.: 05-3234 PREPARED BY: Chuck Mendenhall DATE: 9/23/05 BUILDING ADDRESS: 1060 Auto Center Court BUILDING OCCUPANCY: B, S3 TYPE OF CONSTRUCTION: VN BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 2974 cb Valuation Multiplier City Est . By Ordinance Reg. Mod. VALUE ($) 96,000 :V; 96,000 $522.16 Plan Check Fee by Ordinance Type of Review: C3 Repetitive FeeRepeats Complete Review D Other D Hourly Structural Only Hour* Esgll Plan Review Fee $339.40 $292.41 Comments: Sheet 1 of 1 macvalue.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER £ ADDRESS RESIDENTIAL RESIDENTIAL ADDITION « $10.000.00) TENANT IMPRO PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE PAIRE COMPLETE OFFICE BUILDING OTHER PLANNER ENCINEER DATE DATE b.5 Carlsbad Fire Department Plan Review Requirements Category: TI, COMM Date of Report: 09-16-2005 Reviewed by; Name: SAUNDERS CONSTRUCTION Address: P O 890801 TEMECULA CA 92589 Permit #: CB053234 Job Name: ENTERPRISE RENT A CAR Job Address: 1060 AUTO CENTER CT CHAD St: M INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0000739 1. Note on plans that a minimum of one type 2A:10BC fire extinguisher will be provided, if not already existing. Exitnguisher shall be mounted so that the travel distance to the extinguisher does not exceed 75 ft. 2. Note on plans that any modifications to the sprinkler system will require a separate set of plans to be submitted to the Fire Dept. for review and approval by a licensed sprinkler contractor. Entry: 09/16/2005 By: pp Action: CO James A. Doering STRUCTURAL ENGINEER Structural Calculations for Enterprise rent-a-car Remodel 6460 Marindustry Place San Diego, CA August 25, 2005 Job No: 2005.20 Prepared for Glenn Kennedy Architect l: James A. Doer/fig STRUCTURAL ENGINEER Vertical Design Calculations for Gravity Loads James A. Doer/fig STRUCTURAL ENGINEER JOB NAME: ANALYSIS: 6460 Marindustry JOB NO: ENGINEER: Vertical 2005.20 JAD SHEET NO: DATE:8/25/05 Roof Design Loads Load on Horizontal Projection Dead Loads at Roof Description Clay Tile Roofing Roofing Paper 1/2" Plywood Pre-fab Wood Trusses @ 24" OC Suspended Celling Distributed Mechanical / Electrical Insulation Fire Sprinklers Miscellaneous Roof 10.0 psf 0.5 1.5 3.0 2.5 1.0 0.5 1.5 1.0 Total 21.5 psf Live Load at Roof 20 psf reducible per U.B.C. Table 16-C, Method I Rise less than 4" per foot Member Tributary Area 0 to 200 sq. ft. 201 to 600 sq. ft. over 600 sq. ft. Live Load 20 psf 16 psf 12 psf Rise greater than 4" per foot Member Tributary Area 0 to 200 sq.ft. 201 to 600 sq. ft. over 600 sq. ft. Live Load 16 psf 14 psf 12 psf 2005.20 6460 Marindustry Place/Roof Loads s. .o I Q.E co 01 .£ x °)O C2 LU 1C111 Ul 8iA!7?_ X* tlfc = S6S \N 3 2-7 = /S,2L *• LRFD Beams Rectangular HSS Maximum Factored Uniform Loads in Kips for Beams Laterally Supported Fy=46 ERW Nominal Size Wall Thickness Weight Per Foot Design Wall Thickness 5 £ J2 S B IU 0 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 8x6 5/8 50.81 0.581 1/2 42.05 0.465 3/8 32.58 0.349 5/16 27.59 0.291 1/4 22,42 0.233 3/16 17.08 0.174 462 "332 249 199 166 142 125 111 100 91 83 77 71 66 62 59 55 52 50 370 28T 210 168 140 120 105 94 84 77 70 65 60 56 53 50 47 44 42 278 ~2"2T 166 133 111 95 83 74 67 60 55 51 48 44 42 39 37 35 33 232l9b~ 142 114 95 81 71 63 57 52 47 44 41 38 36 33 32 30 28 186 T5T 117 93 78 67 58 52 47 42 39 36 33 31 29 27 26 25 23 *83 66 55 47 41 37 33 30 28 25 24 22 21 19 18 17 17 8X4 5/8 42.30 0.581 1/2 35.24 0.465 3/8 27.48 0.349 5/16 23.34 0.291 1/4 19.0Z 0.233 3/16 14.53 0.174 1/8 9.86 0.116 Fy.ttksl 378252 189 151 126 108 9584 76 69 63 58 54 50 47 44 42 40 38 324 216 162 130 108 93 81 72 65 59 54 50 46 43 41 38 36 34 32 259 173 130 104 86 74 65 58 52 47 43 40 37 35 32 31 29 27 26 222 148 111 89 74 63 56 49 44 40 37 34 32 30 28 . 26 25 23 22 184 122 92 73 61 52 46 41 37 33 31 28 26 24 23 22 20 19 18 138 ~5T 70 56 47 40 35 31 28 26 23 22 20 19 18 17 16 15 14 ~59 44 35 29 25 22 20 18 16 15 14 13 12 11 10 10 9 9 PROPERTIES lx. in.4 Sx. in. 3 ZK, in.3 0vVn,(klps) *bWc, (kip-ft) 114 28.5 36.1 231 996 98.2 24.5 30.5 185 842 79.1 19.8 24.1 139 665 68.3 17.1 20.6 116 569 56.6 14.1 16.9 92.6 466 43.7 10.9 13.0 69.2 331 81.9 20.5 27.4 231 756 71.7 17.9 23.5 185 649 58.7 14.7 18.8 139 519 51.0 12.8 16.1 116 444 42.5 10.6 13.3 92.6 367 33.1 8.27 10.2 69.2 282 22.9 5.73 7.02 43.0 177 Load above heavy horizontal line is limited by design shear strength. 17 m LRFD Beams Rectangular HSS Maximum Factored Uniform Loads in Kips for Beams Laterally Supported Fy=46 y ERW Nominal Size Wall Thickness Weight Per Foot Design Wall Thickness 5= i &s 8 UJ 0 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 6x4 1/2 28.43 0.465 3/8 22.37 0.349 5/16 19.08 0.291 1/4 15.62 0.233 3/16 11.97 0.174 1/8 8.16 0.116 6x3 1/2 25.03 0.465 3/8 19.82 0.349 5/16 16.96 0.291 1/4 13.91 0.233 3/16 10.70 0.174 1/8 7.31 0.116 Fv*48ksl 201 134 101 81 67 58 50 45 40 37 34 31 29 27 164 109 82 66 55 47 41 36 33 30 27 25 23 22 142 95 71 57 47 41 36 32 28 26 24 22 20 19 118 78 59 47 39 34 29 26 24 21 20 18 17 16 91 61 46 36 30 26 23 20 18 17 15 14 13 12 58 39 29 23 19 17 14 13 12 11 10 9 8 8 167 111 83 67 56 48 42 37 33 30 28 26 24 22 137 91 68 55 46 39 34 30 27 25 23 21 20 18 119 79 59 48 . 40 34 30 26 24 22 20 18 17 16 99 66 50 40 33 28 25 22 20 18 17 15 14 13 77 51 39 31 26 22 19 17 15 14 13 12 11 10 53 36 27 21 18 15 13 12 11 10 9 8 8 7 PROPERTIES lx, \n* Sx, in.3 Z» I"-3 4vVn, (kips) *bWc, (kip-tt) 33.9 11.3 14.6 139 403 28.3 9.43 11.9 104 328 24.8 8.27 10.3 86.7 284 20.9 6.96 8.53 69.5 235 16.4 5.46 6.60 51.9 182 11.4 3.81 4.56 34.6 116 26.8 8.94 12.1 139 334 22.7 7.57 9.90 104 273 20.1 6.69 8.61 86.7 238 17.0 5.66 7.19 69.5 198 13.4 4.47 5.59 51.9 154 9.43 3.14 3.87 34.6 107 21 Cg 'S Q. Ml O;= o T- O) CO T_ o> -; O>o cZ LU 5BT 'PSJt sir ) =. DCUJ 111 ~ 0*90 Page 7 of 9 ER-5279 TABLE 9-^ALLOWABLE TENSION LOADS FOR THREADED ROD INSTALLED IN A CONCRETE FOUNDATION STEM WALL USING SIMPSON STRONG-TIE SET ADHESIVE (SET, SET 1.7, SET-PAC)1^ r-c a 2,000 psi THREADED ROD DIAMETER (inch) ?'7/8 DRILL BIT DIAMETER(Inch) 3/4 MINIMUM EMBEDMENTDEPTH, hy(Inch**) 10 15 MINIMUM WALLTHICKNESS (Inch**) 6 8 MINIMUM EDGEDISTANCE (Inchn) i;/4 l3/4 MINIMUM ENDDISTANCE (inch**) 5 5 TENSION(pounds) 5,750 8,400 For SI: t inch = 25.4 nun, I pound = 4.45 N. 'Reduce allowable tension loads by the reduction factors for elevated temperature (Figure 3), as applicable. 2For short-term loading due to seismic forces under the UBC or wind forces under the UBC or IBC, the allowable loads may be increased 33 Vj percent. 3Allowable tension loads are based on a safety factor of 4.0. TABLE 10—MINIMUM SPACING AND EDGE DISTANCES FOR ANCHORS INSTALLED IN UNREINFORCED BRICK MASONRY ANCHOR CONFIGURATION A B C MMMUM VERTICAL SPACING (Inch**) 18 18 18 MINIMUM HORIZONTAL SPACING (InchM) 18 24 18 MINIMUM EDGE DISTANCE (Inch**) 24 16 24 For SI: 1 inch = 25.4 mm. TABLE 11—ALLOWABLE TENSION AND SHEAR VALUES FOR THREADED ROD INSTALLED IN HOLLOW AND GROUT-FILLED CONCRETE MASONRY UNfTS USING SIMPSON STRONG-TIE SET ADHESIVE (SET, SET 1.7, SET-PAC)1.2-3'4'5-6'7'8 GROUT-FILLED CMU-ANCHOR INSTALLED THROUGH FACE SHELL THREADED ROD DIAMETER (Inch) lk S/8 DRILL DIAMETER(Inch) S/8 3/4 MINIMUM EMBEDMENTDEPTH (inch**) 4l/4 5 EDGE DISTANCE(Inch**) 12 4 END DISTANCE(InchM) 12'/g 45/8 TENSION (pound*) . 1,280 1,550 SHEAR (pounds) 1,245 1,970 GROUT-FILLED CMU-ANCHOR INSTALLED IN CELL OPENING THREADED RODDIAMETER (inch) 5/B DRILL DIAMETER(Inch) 3/4 EMBEDMENT (InchM) 5 EDGE DISTANCE (InchM) 3 END DISTANCE(InchM) 3»/2 TENSION(pound*) 2,510 SHEAR (pound*) 1,905 GROUT-FILLED CMU-ANCHOR M8TALLED IN HORIZONTAL MORTAR JOINT* THREADED RODDIAMETER (Inch) V25/8 DRILL DIAMETER(Inch) % ANCHOR EMBEDMENT(Inch**) 4l/45 EDGE DISTANCE(Inch**) 16 16 TENSION (pound*) 1,590 1,685 SHEAR(pound*) 1,035 1,880 HOLLOW CMU (SCREEN TUBE REQWRED)-ANCHOR INSTALLED THROUGH SINGLE FACE SHELL THREADED RODDIAMETER (Inch) 3/8 DRILL DIAMETER(Inch) 7/8 EDGE DISTANCE(Inch**) 4 END DISTANCE(Inchn) 4S/8 TENSION (pound!) 175 SHEAR(pound*) 540 For SI: 1 inch = 25.4 mm, 1 pound = 4.45 N, 1 psi = 6.89 kPa. 'Threaded rods must comply with ASTM A 307. 2^ues for 6- and 8-inch-wide Grade N, TVpe II, lightweight, medium-weight, or normal-weight concrete masonry units conforming to UBC Standard 21 -4 or ASTM C 90. If the masonry units are grouted, they are to be fully grouted widi coarse grout having a minimum compressivc strength of 2,000 psi, and complying with UBC Section 2103.4 or IBC Section 2103.10. Mortar must be Type S prepared in accordance with Section2103.3oftheUBCandUBCStandard21-15,orIBCSection2103.7. The specified compressive strength of masonry, fm, at 28 days must be a minimum of 2,000 psi. ^Embedment depth is measured from the outside face of the concrete masonry unit for installations through a face shell. 4Anchors are not used to resist seismic forces. Allowable loads are not permitted to be increased for short-term loads due to wind forces. 5Reduce allowable loads by the reduction factors for elevated temperatures (Figure 3), as applicable. *SET 1.7 is not for use in hollow concrete masonry units when screen tube is required. 'Allowable loads are based on a safety factor of 5.0. The tabulated allowable loads may be increased by 25 percent for installations under the UBC. 8Anchors must be spaced a minimum distance of four times the anchor embedment. 'Anchors must be installed in the horizontal mortar joint and into the grouted cell of the concrete masonry units. The shear load must be applied to the anchor perpendicular to the plane of the horizontal mortar joint IK»PS at §"«*§* SS55 111 £ QO < H O 0°S »t <iy Q: O LU fO" P _J K