Loading...
HomeMy WebLinkAbout1060 AUTO CENTER CT; K; CB901370; PermitBUILDING PERMIT Permit No: CB901370 10/12/90 09:17 Project No: A9001526 Page 1 of 1 Developme.xt :.No : I Jbb Address: 1060 AUTO CENTER CT Permit Type: INDUSTRIAL BUILDING Parcel No: 211-080-02-00 Construction Type: VN Occupancy Group: H4 B2 Class Code: Status: ISSUED Description: MEINEKE MUFFLER SHOP Applied: 08/27/90 Apr/Issue: 10/11/90 Str: ** F1: ** Ste: K w2 lG .,.,+E-~-~ 0:: p;?Q ,. ,. ,. ;:-$T#? ,,j'.. , Li I ,!(! s w/30f Valuation: 49,200 Validated By: CD Appl/Ownr : RICK MARRS INC 4 6 5 2 0 11 8330 UNIVERSITY AV LA MESA, CA 92041 ~ OWNER : CARLTAS CO 4401 MANCHE __ OWNER 6327344 20 .00 47.00 ENC I NITAS *** Fees Required Fees : Adjustments: Total Fees: __-----------_______ Fee description _-_______-________ Building Permit Plan Check Strong Motion Fee Enter 'Y' to Autoca F.M.F./G.M.F. and 2.0 Traffic Impact Fee Enter Number of EDU's MFF * BUILDING TOTAL Enter "Y" for Plu Each Plumbing Fixture or Trap 5,294.00 Ext fee Data 415.00 270.00 7.00 1722.00 Y N 1296.00 1456.00 5166.00 17.50 7.50 Y 6 Each Building Sewer > * PLUMBING TOTAL Enter "Y" for Electric Issue Fee > Three Phase Per AMP > * ELECTRICAL TOTAL ($10 Minimum) Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts > Each Install/Reloc Appliance Vent > * MECHANICAL TOTAL 1.00 6.50 6.50 32.00 200.00 .50 100.00 105. 00 1.00 9.00 9.00 3.00 4.50 13.50 38.00 5.00 Y 15.00 Y n J 2075 Las Palmas Or., Carisbad, CA 92009 (6191 438-1161 1. BERMIT TYPE - ~MMERCIM UNEU WNAUl IMPRWEMENT 1- I n . b INDUSTRIAL OUEU OlENANT IMPROVEMENT C . ORESlDENllAL OAPARlMENT OmOD OSiNGLE FAMILY DUELLING nMDlTiON/ALTERAllOY SIGNATURE AGEHl FOR COIITRKTOII ADDRESS &cq 6.& CilY STAT ZIP tWE DAY TELEPHONE -- - DAY TELEPHONE NAME ADDRESS 43 I- SLOO CITY STATE LIP CWE DAY TELEPHONE ciiy nusims LIC. x SlATE LIC. X LICENSE CLASS SIGNATURE TllLE DAlE DESIGNER WME MDRESS CITY STATE ZIP cmE DAY TELEPHOYE 61171 LIC. X Uorkcrsa Cnpnsation Declaretion: i hereby affirm that I have a ceitificate Of ~msenf IO self-insure issyed by CheDirector of idsfrial Reiations. 01 a Ccrflficafe of Yorkers' Capmation In6urlnce by an ahiffed lns~rel, or an cllcf cow or 9iicatr thereof certified by the Director of the imuier thereof filed with the nuildiw impction Deprtnmt (Section 3800. Lab. c). 7. WORKERS' COMPENSATION INSURANCE CDllPANY POLICY NO. EXPIRATION DATE Certificate of Exaption: so as to bacm slaject to the Yortcrs' C-ration Law of California. I certify that in the prformme of the Yolk for which this pmif is issued. i shall wt aploy any prim in any mmr SIGNATURE DAlE 8. OWNER-BUILDER DECLARATION Ounr-Buii&r DCci~letlon: I hemby affirm that I am excnpf frm the Contractor's License Law for rhr following resem: 0 1 0s Owe? Of the ploperfy or "y apioyeer with wager as the?? sole capensarion. "ill do the work end the sfr~~ture if not intended 01 offered for sale (Src. 7044. Business and Plafeasionr Code: The Contractor's License tau does not awiy to an omel of pv0prfy who builds or inproves thereon,, ard who does IWh nrk hineeif or fhr0-h hi9 OM" aployeer. provided that such inproverents arc not intended or offered for mie. if, however, the building or inprovmnx is soid within me year of cnpietion. the owner-builder will have the burden of proving that he did not build or inprove fop the pli@oc of sale.). 0 I, as -r of the ploprfy. am exclusively Contiacting with licmsed contractors to Constrwt the projest (Scc. 7011. BUOineis ard ProfeOsimP Code: The CmtlaStOl'l License Law does mt apply to an wner of proprfy who builds or inpravcr thereon. and ~mfvacf~ for such projects with cmtiaCtor(6) iicensed prsumf to the Contractor's License Law). 0 I rn cranpt under section Burinerr wd PrOfesSim0 ccde for this ieasm: (Sec. 7031.5 nusine08 and Piofessions Code: Any City 01 Canfy which requires a pmif to ~onifi~f. alfev, inprove. demolish. 07 'vir any strucf~m, prior to its isscawe, also r-ires the ewlicmt for such pmit to tile II signed staterent that he io iismsed pmuanf to the pmvislmr of the Contractor's License Law (Chaptcr 9. cmnsing with Secfim 7000 of Division 3 of the susineii and PiofesOionO Code) 01 that he is exngf therefran, and the basis for the alleged exaption. Any violation of Section 7031.5 by any applicant for a permit sbjectr the applicant to II civil penalty Of not mrc than five hundred da111rS II5001). SIGNATURE DATE CfflPLETE THIS SECTiOY FCR YON-RESIOEYTiN BUILDING PERMilS ONLY: Is the applicant or fufule building occupant required to subnit a business pian. wutely hazardous mferials registration form 01 risk m~1~g-f 4 prevmfim prqsran under sectimn0 25505, 25533 or 25534 of the Prraley-Tamr HalardWP Shfsme Account Acf? 19 the ewlicanf or future building occwnf required to obtain a pnif trm the aiv Pollution cmfrol district or eir wality mnagmnf di(itiict7 Is the facility to be comfrlwfed within 1.000 feet of the Outw mry of c SchWi site7 OYES 0 YO DYES 0 yo DYES 0 NO IF U1 OF 1HE U-5 ARE 1ES. A FlUL CERTlFlUlE OF OCCLPUO UY MOl IE IS- AFTER MI 1. 1989 MESS TIE WPLIu*T HAS El 01 IS IEETIffi 1E RE(uIEl!€MlS OF IK OFFICE OF EIEROEUCY SERVICES uo TIE AIR munica mrm nisiuici. 9. CONSTRUCTION LENDING AGENCY I heretv affirm that there is a construction Lending agemy for the prformmc of the work for which this prmif is issued (SCC 3097Ci) Civil Code) LENDER'S NAME LENDER'S ADDRESS 10. APPLICANT'S SIGNATURE I certify that I have read the appiicafion and rfafe that the stove information is correct. I agree 70 cnpiy with ali City ordinawes and State iaw9 reieting to building COnStlYCllon. I ALY) AmEE 10 SAVE IYDEWIFI AND KEEP HMLESS THE CiTY OF CARLSW AGLINSl ALL LIABiLITIES. lloMEMlS. mSTS WO EXFfYPS UNICN UY IN Ul WY ACCW WINST YID I hereby aufhorlze represenfafiver of the City of Carlrbsd to enter upan the abve menfioned property for inrpcfion pvpascs. ciiy IN ~YWEIICE OF THE WANTING OF inis EMIT. Expiration. Every pmif issd by the Building Official under the provisions of this Code shall expire by limitation and becm Nli and void if the building or work authorized tv such permif is not cmced within 180 dayr frm the date of such pnit or if the building or work authorized by such permit is rvspnded o? abadmed at my tine after the uork is cmnced far a period of 180 day$ (Section 30Xd) Uniform Building Code). c) MER OCWTRACTCR APPSWED BY: DATT; Ap6icant' PINK: Finance FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING PLANNING U/M WATER PLAN CHECK#: CB901370 PERMIT#: CB901370 PROJECT NAME: MEINEKE MUFFLER SHOP ADDRESS : CONTACT PERSON/PHONE#: TZ/MH/WILLIE/931-0971 SEWER DIST: CA WATER DIST: CA DATE: 11/02/90 PERMIT TYPE: INDUST f’ CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB901370 FOR 11/02/90 INSPECTOR AREA PK DESCRIPTION: MEINEKE MUFFLER SHOP PUCK# CB901370 TYPE: INDUST CONSTR. TYPE NEW JOB ADDRESS: 1060 AUTO CENTER CT STR:** FL:**** STE: K APPLICANT: RICK MARRS INC PHONE: 4652011 CONTRACTOR : PHONE : OWNER: CARLTAS CO PHONE: 632734 OCC GRP 006 REMARKS : T2/MH/WILLIE/9 3 1-097 1 SPECIAL INSTRUCT: Th’ BA TOTAL TIME: INSPECTOR /!!/ --RELATED PERMITS-- PERMIT& TYPE STATUS SE900116 SWcI ISSUED CD LVL DESCRIPTION ACT COMMENTS 3 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical - -- - -- - -- 4 ***** INSPECTION HISTORY ***** DATE DESCRIPTION 103190 Rough Combo 102290 Rough/Topout 102290 Rouqh Electric ACT INSP COMMENTS PA PK AP PK AP PK CONDUIT IN WALLS 102290 Und&ground/Under Floor AP PK 101990 Underground/Under Floor co PK LEAKED 101690 Interior Lath/Drywall NR PK CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB901370 FOR 11/01/90 INSPECTOR AREA PK DESCRIPTION: MEINEKE MUFFLER SHOP PLANCK# CB901370 TYPE: INDUST CONSTR. TYPE NEW JOB ADDRESS: 1060 AUTO CENTER CT STR:** FL:**** STE: K APPLICANT: RICK MARRS INC PHONE: 4652011 CONTRACTOR: PHONE : OWNER: CARLTAS CO PHONE: 6327344 29i9 OCC GRP REMARKS: Tl/MH/WILLIE/931-0971 SPECIAL INSTRUCT: INSPECTOR /Au TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS SE900116 SWcI ISSUED CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural Af 29 PL Final Plumbing z s 39 EL Final Electrical 49 ME Final Mechanical - -- - -- - -- ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 102290 Rough/Topout AP PK 102290 Rough Electric AP PK CONDUIT IN WALLS 102290 Underground/Under Floor AP PK 101990 Underground/Under Floor CO PK LEAKED 101690 Interior Lath/Drywall NR PK CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB901370 FOR 10/23/90 DESCRIPTION: MEINEKE MUFFLER SHOP .1 TYPE: INDUST JOB ADDRESS: 1060 AUTO CENTER CT STR: ** APPLICANT: RICK MARRS INC PHONE: 4652011 CONTRACTOR: PHONE : OWNER : CARLTAS CO PHONE : 6 3 2 7 3 4 4,@6 INSPECTOR AREA PK PLANCK# CB901370 OCC GRP CONSTR. TYPE NEW FL:**** STE: K REMARKS : T2/MH/WI LLIE/ 9 3 1 - 0 9 7 1 SPECIAL INSTRUCT: INSPECTOR !& TOTAL TIME: --RELATED PERMITS-- PERMIT$ TYPE STATUS SE900116 SWcI ISSUED CD LVL DESCRIPTION ACT COMMENTS 17 ST Interior Lath/Drywall x -- -- - ~- - ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 101990 Underground/Under Floor CO PK LEAKED 101690 Interior Lath/Drywall NR PK ESGIL CORPORATION 0320 CHESAPEAKE DR.. SUITE 208 SAN DIEGO, CA 02123 (610) -1468 FILE COPY DATE : a?. 9 ’ lw& PLAN CHECK NO: csu- 13’lo SET: n PROJECT ADDRESS: /ob0 AUTO C?? cz PROJECT NAME: p!n ,*P 131k f+Ier JURISDICTION: CQr-lS hd DUPS GDESIGNER The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply 0 with the jurisdiction‘s building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. 0 The applicant’s copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. 0 The applicant’s copy of the check list has been sent to: 0 identified on the enclosed check list and should be corrected BEsgil staff did not advise the applicant contact person that 0 Esgil staff _. did advise applicant that the plan check has plan check has been completed. been completed. Person contacted: Date contacted: Telephone # 0 REMARKS: By: &24&J kfw & Enclosures: ESGIL CORPORATION 4 ,* /a- 9 OGA OAA URN ODM ESGIL CORPORATION 0320 CHESAPEAKE DR.. SUITE 208 SAN DIEGO. CA 02 I23 (610) 550-1468 DATE : 28, JURISDICTION: cq r /? ked OFILE COPY PLAN CHECK NO: ?&- 12 70 SET: n OUPS PROJECT A QO -f- Cfi cr CDESIGNER The plans transmitted herewith have been corrected where building codes. The plans transmitted herewith will substantially comply 0 with the jurisdiction's building codes when minor deficien- 0 necessary and substantially comply with the jurisdiction's cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies and resubmitted for a complete recheck. 0 identified on the enclosed check list and should be corrected The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the 0 jurisdiction to return to the applicant contact person. @The applicant's copy of the check list has been sent to: krCFpij c PI- E964 Gdf 0,. >br.;p &//$- (4 '7 - ; .> -7, < _- LLJ 2 I Esgil staff did not advise the applicant contact person that plan check has been completed. 0 Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone # 0 REMARKS: $ JURISDICl'ION: CLir 1s h@d/ Date plana received by plan checker: T-z/ PLMl CKECK NO.: 90- J37O Date plan recheck completed: 7-26 By: YhIClfip/ k I-Q fr PROJECT ADDRESS: IO60 A,,h C@,,YG&- c* To: c--Qt.;wftc; C2,aOP - &dF & S;/q 127 V~//E(, / RE(3IEcK PLAN WRRECTI ON FORGWORD: WEREAD Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation. noise attenuation and disabled access. The plan check is based on regulations enforced by the Building Inspection Dapartment. You may have other corrections based on laws and ordinances enforced by the Planning Deparrment, Engineering Department or other departments. The items shown below need elarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), of the Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. 0 following items have not been resolved from previous plan reviews. The original Please &e all corrections on the original correction number has been given for your zngs and submit two new sets of prints, reference. vF - -upy and any original plan sets that may have been ai u*l". sunwct+m l' -, .I_ kae . Please contact me returned to you by the jurisdiction, to: imtions regarding these ?';;A0 €hp;.?#/c.j.& vr. utf, cg items. zsi/ - CO-. lrr 0 4. Please indicate here if any dranges have been made to the plans that are not a result of corrections from this list. If there are 0 sir Diicqo c.4 92/23 " 0 To facilitate :echeckiw, please identify. - next to each item, the sheet of the pl& other changes, please briefly describe them upon which each correction on this sheet bas been made and return this check sheet with the revised plans. Have changes been made to the plans not resulting from this correction list? Please check. and where they are located on the plans. Yes No @ Clciirr'IC r( OM Plot $/=ut5 l.Qlre1-e Ib-7 I L., ~r//s ci/F pro 9cdc:c; / cJ5a,/ I: 'y,Je=, 1.5 .rp fqMr q r- For /.11u,n A&,-&, > a, ? o- bo++ bq, -/d/i?o 5 7 . Prov,2-/P 0 d,,;7 Q,5,,..~ACJ TG dOce,,t e:,, - I f-l,,. J:l(.p 4 I C.Q. 4 A,, =+I#/ U , . . . :. .. . . ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DlEGO. Ch 92123 (619) 560-1468, - The plans transmitted herewith have been corrected where building codes. The plans transmitted herewith will substantially comply 0 necessary and substantially comply with the jurisdiction's 0 with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the The applicant's copy of the check list has been sent to: 0 identified on the enclosed check list and should be corrected 0 jurisdiction to return to the applicant contact person. 6-PbI-s ea- CooPer .. 0 Esgil staff did not advise the appl-icant contact person that 0 Esgil staff _. did advise applicant that the plan check has plan check has been completed. been completed. Person contacted: G&czI-~ GqY.ei- Date contacted: Telephone # ybq- YOZZ ' 0 REMARKS: By: m,&Jq& ./ Enclosures: ESGIL CORPORATION Date plans received by jurisdiction: Date plans received by Esgil Corporation: Date initial plan check completed: Applicant contact person: FcmmRD: PLgASBREAD Plan check is limited to technical requiremnts contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulatirig energy conservation, noise attenuation and access for the handicapped. "he plan check is based on regulations enforced by the Building Inspection Department. You nay have other corrections based on laws and ordinances enforced by the Planning Department. Engineering Department, Fire Department or other departments. Code sections cited are based on the 1988 UBC. The circled items listed need clarification, modification or c-e. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1988 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To swed UD the recheck Drocess. note on this list lor a CODV) where each correction item has been addressed. i.e.. 01- sheet. specification. etc. Be sure to enclose the marked UD list when vou submit the revised Dlans. II[W: PAGE mmms ARE ROT m ~~~CEAS PAGES rnvm~o mns mmm3 camm~ons=~. LIST NO. 58 TENANT IMPROVDEhT WITH(xpp SPECIFIC ENERGY ZONE DATA OR WLICY SUPPLMENTS, 1988 UBC *. > Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corporation, 9320 Chesapeake Drive, Suite 1208, San Diego, CA (619) 560-1468. 0 0 92123, OC Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction's building department. /Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. Section 302(d). Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. ,/Plans and calculations shall be signed by the California state licensed engineer or architect where there are stmctural changes to existing buildings or structural additions. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. / Provide the correct address and suite numbar of tenant space on the plans. fl Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled. Section 302. When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy. Please provide complete details to show the building with comply. Section 502. /UBC Section 304 requires the Building Official to determine the total value of all construction work proposed under this permit. The value shall include all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment. Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed. Provide a plot plan showing the distance from the building to the property lines and the location of tenant space (or remodel) within 0 Section 302(d). the building. Ala0 5b 41-t. To Adj ec4ir~T Ju'%)ss 11. On the first sheet of the plans indicate: Type of construction of the existing building, present and proposed occupancy classifications of the remodel area and the occupant load of the remodel areas and the floor where the tenant improvement is located. Arovide a note on the plans indicatin if any hazardous materials will be stored and$or used within the building which exceed the quantities listed in UBC Tables 9-A and 9-B. /A complete descri tion of the activities and processes that wily occur in this temt space should be provided. A listing of all hazardous materials should be included. lhe materials listing should be stated in a form that would make classification in Tables 9-A and 9-B possible. The building official may reauire a technical reoort to identifv and deGelop methods of prdtection from ha&dous materials. Section 901(f). .ld If control areas are used for exceeding the exempt mounts of hazardous materials from Tables 9-A and 9-B, they shall be constructed of not less that required for a one-hour occupancy separation. Section 404. ,&!/&e number of control areas within a building used for retaillwholesale stores shall not exceed two; the number of control areas in buildings with other uses shall not exceed four. Footnote 1, Tables 9-A and 9-B. /The aggregate quantity of any hazardous materials "in use" and "in storage" shall not exceed the quantity listed in Tables 9-A and 9-B for "storage". Footnotes 2 and 3, Tables 9-A and 9-B. /Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1988 UBC, UHC and UF'C and 1987 NEC . ,Id Provide a fully dimemionad floor plan showing the size and use of all rooms or areas within the space being improved or altered. Draw the plans to scale and indicate the scale on the plan. Section 302(d). Indicate the use of all spaces adjacent to the area being remodeled or improved. @ Show any existing fire rated area separation walls, occupancy separation walls, demising . walls, shafts or rated corridors. Identify and provide construction details for proposed new fire rated walls. Specify on the plans the fire ratings of assemblies to protect proposed openings in existing or new fire walls. @ .. Identify existing walls to be removed, existing /walls to remain and proposed new walls. Identify bming walls, non-bearing walls, and shear walls. Provide a section view of all new interior partitions. Show: (a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". (b) Method of attaching top and bottom plates to structure. (NOTE: Top of partition mst be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load). (c) Wall sheathin material and details of attachment $size and spacing of fasteners). (d) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. Provide notes andlor details to show that the floor and wall finish in toilet rooms are surfaced with a smooth hard non-absorbent material extending five inches up the wall. Similar surfacing shall be provided on the walls from the floor to a height of 4 feet around urinals and within water closet compartments. Section 510(b). "All interior finishes must comply with Chapter 42 of the UBC". Specif "class flame spread rating (minimmy for Lateral bracing for suspended ceiling nust be /provided . (UBC Table 23-P) Where ceiling is not supporting interior partitions, ceiling bracing shall be provided by four No. 12 gauge wires secured to the main runner within 2 inches of the cross runner intersection and splayed 90 degrees from each other at an angle not exceeding 45 degrees from the plane of the ceiling. A strut (adequate to resist the vertical component from lateral loads) fastened to the main runner shall be extended to and fastened to the structural members of the roof or floor above. These horizontal restraint points shall be placed 12 feet O.C. in both directions with the first point within 6 feet of each wall. Attachment of restraint wires to the structure above shall be adequate for the load imposed. UBC Standard 47-18. ;Is( Note on the plans: 1. In buildings having floors and roofs of wood frame construction, other than dwelling or 4 hotel occuoancies. draft stoo the area between I the ceilihp: ani floor above so that no concealed space exceeds 1,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 3,000 s.f . and 100 L.F. 1. Section 2516(f). 8. In buildings having floors and roofs of wood frame construction, other than dwelling or I hotel occuDancies. draft stoD the area between I the. ceiliip. and roof above so that no concealed space exceeds 3,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers then 9,000 s.f. and 100 L.F.). Section 2516(fj. I the. ceiliip. and roof above so that no concealed space exceeds 3,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 9,000 s.f. and 100 L.F.). Section 2516(f). dStorage areas exceeding 1000 sq. ft. in connection with wholesale or retail sales shall be separated from the public area by a one-hour occupancy separation. If the entire building has an automatic sprinkler system, then the occupancy separation need not be provided. dh automatic sprinkler system shall be installed in rooms used by the occupants for the consumption of alcohol and in accessory uses where the total area of such weparated rooms and assembly uses exceeds 5000 sqwe feet. Section 3802(c). The tenant space and new andlor. existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. See the attached correction sheet. p/ The width of the required level area on the side into which doors swing shall extend 24 inches past the strike edge for exterior doors and 18 inches past the strike edge for interior doors. ,3d Specify lever-type hardware for passage doors on floors accessible to the disabled. Section 2-3304, Title 24. /If both sexes will be employed and the numk of employees exceeds four, provide separate toilet facilities for men and women. If "both sexes will be employed and the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan. Section 705. @ Title 24, Part 2. Section 2-3304, Title 24. . 35. In areas where the occupant load exceeds -, two exits are required. See . Table 33-A. 2/15/90 3 / Provide an exit analysis l& (may be 8 112" x 1110 or any convenient sizep. Exits should have a mininum separation of one- / half the maximum overall diagonal dimansion of the building or area served. y. The maximum number of required exits and their required separation must be maintained until egress is provided from the structure. Section 3303(a). RO&S with more than 10 occupants may have E exit through 2 adjoining room. Revise exits to comply. Section 3303(e). J&? Exit signs are required for exits serving an occupant load exceeding 49. Show all required exit sign locations. Section 3314(a). fl Show that exits are lighted with at least one foot candle at floor level. Show the locations of existing exits from the building and show the path of travel from the remodel area to the existing exits. Note on the plans: "All exits are to be openable from inside without the use of a key or soecial knowledee". In lieu of the above. Section 3303(c). Section 3313(a). 15. 46. 47. 48. in a-Group B occupikcy, you may note "Provide i sign on or near the exit doors reading THIS I DOOR TO REMAIN uNII)cKED DURING BUSINESS HOURS". This signage is only allowed at the g& exit. Section 3304(c). I . Exit doors should be a minimum size of 3 feet by 6 feet 8 inches with a minimum door swing of 90 degrees. Haximum leaf width is 4 feet. Section 3304(f). Exit doors should swing in the direction of egress when serving an occupant load of 50 or more or when serving any hazardous area. Section 3303(b). Applies to door(s) Regardless of occupant load, a floor or landing not more than 112 inch below the threshold is required on each side of an exit door used for disabled access (may be 1" maximum where not used for disabled access). Doors should not project more than 7 inches into the required corridor width when fully opened, nor more than one-half of the required corridor width when in any position. Section 3305(d). Revolving, sliding and overhead doors are not permitted as exit doors if the occupant load exceeds 9 or the exit door serves a hazardous area. Section 3304(h). Section 3304(i). Exit doors from assembly rooms with 50 or more occupants shall not be provided with a latch or lock unless it is panic hardware. Section 3318. Double acting doors are not allowed when serving a tributary occupant load of more than 100, or when part of a fire assembly, or part of smoke and draft control assemblies or when equipped with panic hardware. Section 3304(b). Corridors must provide continuous protection to the exterior of the building. Interruptions by an intervening room is not permitted. Foyers, lobbies or reception rooms constructed as required for corridors are not considered intervening rooms. Section 3305. Corridors and exterior exit balconies serving 10 or more occupants must be a minimum 44 inches wide and 7 feet high to the lowest projection. Corridors serving less than 10 occupants must be a minimum of 36 inches in width. Section 3305(b). When two exits are required, dead end corridors and exit balconies are limited to 20 feet. Section 3305(e). Corridors serving 30 or more occupants shall have walls and ceilings of one-hour construction except: a. Corridors greater than 30feet wide when the occupants have an exit independent from the corridor. b. Exterior sides of exterior exit balconies. C. Corridor walls and ceilings need not be of fire-resistive construction within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with M automatic sprinkler system throughout and smoke detectors are installed within the corridor in accordance with their listing. Section 3305 (g). Section 3305(g), Exception 5, cannot be used for non-rated corridors in a fully sprinklered office space if the occupant load in the space exceeds 100. Section 3305(g), Exception 5 does not apply to cmn corridors where the corridor serves as an exit for non-office areas (manufacturing, warehouse, etc.). ~ 2/14/90 4 55/ Section 3305(g), Exception 5 is applicable only for corridors on one floor; the corridors on the lower level(s) must be rated if these lower corridors have openings into them from other levels. If non-rated corridors are used per Section 3305(g), Exc. 5, provide a reference to the corridors on the floor plan, noting: 6 7 1. 2. 3. 4. 61. 65. 65. 61. 63. !. ). Corridors are non-rated per Section 3305(g), Exception 5. Smoke detection system must be listed by the State Fire Marshall and be a supervised low voltage system. Smoke detectors shall be maximum 30' on center. Power supply shall be dedicated branch circuit. Circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly marked AJ.,ARM CIRCUIT CONTROL, with a lock-on device. . If a tenant space utilizes Section 3305(g), Exception 5, then that tenant space shall be separated from adjacent spaces by a demising wall constructed as for a one-hour corridor wall. . Clearly show where the non-rated corridor system terminates and a rated corridor system comences. . One-hour fire-rated corridors shall have door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes, except openings in interior walls of exterior exit balconies. Doors shall be maintained self-closing or be automatic-closing by action of a smoke detector per Section 4306(b). Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 3305(h). . Show rated corridors, lobbies, reception or foyers cross-hatched on the floor plans. . Total area of all openings, except doors, in any portion of an interior corridor, shall not exceed 25 percent of the area of the corridor wall of the room which it is separating from the corridor. Such openings shall be protected by fixed, approved 114 inch thick wired lass installed in steel framas. Section 3305(hf. Provide a complete architectural section of the corridor, or exterior exit balcony, showing all fire-resistive materials and details of construction for all floors, walls, ceiling and all penetrations. Section 3305(g). Show the location of fire dampers. Provide fire dampers at duct penetrations of fire- rated occupancy and area separations, shafts and corridor walls and ceilings. Section 4306(j). If a room with an exhaust fan has a door opening into a rated corridor, show how make- up air will be provided to the room. Ihe door cannot be undercut, nor can a louver in the door be provided. Section 3305(h)1. If building exceeds two stories and has an elevator opening into a rated corridor, show how the smoke and draft control provision of Section 3305(h) will be met. Either provide a separated elevator lobby or a second door at the elevator entry meeting the provision. If a second door is provided at the elevator entry, note that it will be readily openable from the car side without a key, tool or special knowledge or effort. Provide evidence of Health Deoartment aooroval Section 5106. (for restaurants or for te&ts usinLx-ray equipment). When nonflamable supply cylinders for &dial gas systems are located inside buildings, they shall be in a separate room or enclosure separated from the rest of the building by not less than one-hour fire-resistive construction. Doors to the room or enclosure shall be self-closing smoke- and draft-control assemblies having a fire-protection rating of not less than one hour. Rooms shall have at least one exterior wall in which there are not less than two vents of not less than 36 square inches in area. One vent shall be within 6 inches of the floor and one shall be within-6 inches of the ceiling. When an exterior wall cannot be provided for the room, automatic sprinklers shall be installed within the room and the room shall be vented to the exterior through ducting contained within a one-hour- rated shaft enclosure. Approved mechanical ventilation shall provide six air cbanges per hour for the room. Section 702(b)4. 6113lYU 5 . . Submit plan showing location of all panels. Submit panels schedules. Submit electrical load calculations Indicate existing main service size. Indicate existing total main service load. Indicate new additional loads. method, i.e. EXT, metal flex. Show exit signs on the electrical lighting ~lanf~). As oer Section 3313 and 3314 of the i988'~6C, probide two sources of power to exit signs and exit illumination. Provide receptacle(s) within 25' of the roof mounted AIC units. UMC Section 509. Provide multiple switch lighting controls per Title 24, 2-5319. Provide an electrical plan for the alarm system showing compliance with criteria described under earlier correction number 54. Provide mechanical ventilation in all roams capable of supplying a minimum of 5 cubic feet per minute of outside air with a total circulation of not less than 15 cubic feet per minute per occupant. Section 605 and 705, UBC. Provide mechanical plans showing existing and pro osed WAC equipment, ducts and access to equtpment . Detail access and workin clearances to WAC $. Cooling coils or cooling units located in attic or furred space, where damage may result from condensate overflow, shall be provided with an additional water tight pan of corrosion resistant material to catch overflow if primary condensate drain becomes clogged. Section 1205, W. 86 One-how corridors shall not be used as an integral part of a duct system. This includes the space above a dropped ceiling within the one-hour corridor. UMC Section 706(b). @ SClOW ROO$ %CGB)S LA4#6& . Provide gas line plans and calculations, ' showing pipe lengths and gas demands. UPC Section 1219. @ Provide drain, waste and vent plans. 8 $. Provide water ine sizing calculations. SHou V&rg l"0.c FAa X)na*-~ fwEcce, Section 1009. Detail how floor drain trap seal is to be maintained. UPC Section 707 (floor dyin trap Show P & T valve on water heater and detail drain line route from P & T valve to the exterior. UPC Section 1007(e). Show 114'' per 12" slope on drain and waste lines. UPC Section 407. Provide a drinking fountain at each floor level in assembly occupancies (except drinking and dining establishments). EBa Provide complete energy design calculations, including all existing design and new energy design for this building. See attached non- residential energy design checklist. For remodels in an existing conditioned space, show that the remodeled space will not use more energy than the existing space or show the remodeled space will conform to latest energy design standards. priming). &zpA<A?tc an 1.J 5 9 ua7s :Le act) LRU. LIBC Section 605. Please see additional corrections or remarks that follow. To speed up the recheck process, note on this list (or a copy) whee each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. Yes No .. 1 m: The following provisions are contained in Title 24, Part 2, California Building Code, as adopted and enforced by the State Fire Marshall. They are provided here as a courtesy to assist designers in developing the project documants. All applicable provisions may not necessarily be included. Please direct any questions regarding interpretations of these provisions to the local Fire Department. Walls of corridors and exterior exit balconies in Groups A,E,I,R-1 and C Occupancies having an occupant load of more than & persons and in all other occupancies having an occupant load of 30 or more shall be not less than one-hour fire-resistive construction. Section 3305(g)1. /mere sexit signs are required by Section . 3314(a), approved and listed internally, externally or self-illuminated low-level exit signs complying with Section 3314 shall be . required. The bottom of the sign shall be not less than 6 inches nor more than 8 inches above ’ the floor level. For exit way doors, the sign shall be on the door with the closest edge of the sign with 4 inches of the door frame or adjacent to the door. Such signs shall be of a type which is perce tible to the sense of touch. Section 3314(ep. WWhere exit signs are required by Section 3314(a), all exit corridors shall be provided with continuous low-level exit path marking. Approved and listed internally or self- illminated marking shall be installed at floor level or no higher than 8 inches above the floor level. Such marking shall be of a type which is perce tible to the sense of touch. Section 3314(f$. drea separation walls shall not be considered to create separate buildings for the purpose of automatic fire-sprinkler system requirements as Set forth in Chpter 38. XKClWJZW: Buildings separated by continuous area separation walls of four-hour fire- resistive construction without openings. Buildings required to have automatic fire- sprinkler protection as set forth in Section 13113 of the Health and Safety Code (homes for children or the aged) are prohibited from using area separation walls in lieu of automatic fire-sprinkler protection. &In educational occupancies, storage and janitor closets shall be of one-hour fire-resistive Construction with openings protected by assemblies having at least a three-fourths- hour fire-resistive rating. Section 802(c). I Section 505(e)6. 6Section 1807 should be reviewed for all high- rise buildings. dThe exception in Section 3318 of the UBC has been revised so aa to allow the omission of panic hardware at the main exit in churches (by using signage), only when the occupant load of the church is less than 300. df emergency warning systems are required, they shall activate a means of warning the hearing impaired. Flashing visual warnings shall have a frequency of not more than 60 flashes per minute. Ihe jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact at Esgil Corporation Thank you. Enclosures: 1/8/90 7 U .. .. 2 : U n i TITLE 24 HANDICAPPED ACCESS CORRECTION LIST References to section numbers With prefix "2" are to Title 24, California Code of Regulations, Part 2 (California Building Code). Prefix "3" is for Part 3 (California Electrical Code). Prefix "5" is for Part 5 (California Plumbing Code). Exemptions claimed for any item shall be requested in writing and shall include all data needed to determine "unreasonable hardship" as described in Section 2-422. W a. Provide * of handicapped spaces f 2-7102(b) b. Space shall be so located that handicapped persons are not compelled to wheel or walk behind parked cars other than histher own. 2-7102(c) C. Parking space shall be a minimum of 9 ft.xl8 ft. with adjacent marked 5 ft. loading zone. Double space shall be 23 ft. wide. Where a single space is Drovided. the loadindunloadinn zone "- hall & on the asskeer side of the vehicle. 2-710Z(c)P d. Haxirmrm slope of parking surface in any direction shall not exceed 114" per foot. 2-7102(e). e. Parking space(s) shall be identified with the International Symbol of Accessibility on reflectorized sign affixed to post or wall, and also duplicated on parking surface (symbol to be 36"x36" and painted at the back of the Darkinn stall). 2-7102ff) f. Entrance to parking area (or at each stall) shall have a si stating that unauthorized vehicle(s$ parking in handicapped space s) may be subject to tow-away. 2-71021f) g. Entrance to and vertical clearance within accessible level of parking structure shall be 8 ft. 2 in. to any structural mmber, duct or pipe. 2-7102(g) . Curb ramps shall be loeatedwherever pedestrian path crosses curb. (2- 7103(a)) . Curb ramp shall be 48" min. width (2- 7103(b)) with maximum slope of 1 in 12. 2-7103(d) . A level 48" min. depth landing is required at top of curb ramps over entire curb ramp width. 2-7103(6) . If no landing is provided, the slope of flared rides shall not exceed 1 in 12. I 2-7103(d) e. Surface is to be slip resistant and a contrasting finish from adjacent sidewalk. 2-7103(f) f. Border markines shall be 12" wide of 1/4"x114" groo;es, 314" apart, located at top and sides. 2-7103(h) a. Site development and grading shall be designed to provide access to primary entrances and access to normal paths of travel and where necessary to provide access shall incorporate pedestrian ramps, curb ramps, etc. 2-7101(a) b. Walks sloping greater than 5% (1 in 20) must comply with ramp requirements of Sec. 2-3307. 2-3325(c) -0 c. Walk width shall be 48" minimum, and shall have slip-resistant surfaces. 2-3325(a) d. The maxh cross slo e shall not exceed 114" per foot. 2-3325fa)3 e. Gratings are not allowed whenever possible. '2-3325(b) f. At each gate or door a bO"x60" level area is required when the gate swings toward the walk. 2-3325(e) g. A 4Wx44" deep level area is required wimn the gate swings away from the walk. 2-3325(e) side of gate or door. h. A 24" clear space is required at strike 2-3325(e) r,pE31EsIRIMIRAHPS . A path of travel with a slope greater than 1 in 20 shall be considered a ramp. 2-3307(a) T . The maximum slope shall be 1 in 12. 2-3307(c.l) . The width shall be 48'' minimum. A minimum width of 60" is required where a ramp serves as a primary entrance to buildings having an occupant load of 300 or mre. Group R Occupancies may be 36" when the occupant load is 50 or less. 2- 3307(b.l) . ,, -, 1 c 4 d. e. f. g. h. i. J. Y. Headroom of 80li minimum shall be maintained for walks, corridors, aisles, etc. 2-522(f) . Protruding objects with leading edges between 27" and 80" above finished floor shall not protrude more than 4" into walks, corridors, etc. 2-522(f) . Free standing objects mounted on posts between 27" and 80" above the floor may project a maximum of 12". 2-522(f) I!. Abrupt changes in level exceeding 4" adjacent to walks, except between walks and adjacent streets or drives, shall be The surface of ramps shall be slip- resistant. 2-3307(g) A 60" intermediate landing is required at maximum elevation change of 30" and 72" landing at each change of direction (over 30 degrees). 2-3307(d.1) Landings are required at top and bottom of ramps. 2-3307(d.l) Bottom landing shall be minimum of 72" in the direction of travel. Fig. 2-33- 11A Top landing shall be 60" x 60" minimum. 2-3307(d. 1) When' door swings onto top landing, minimum depth of landing required is door width plus 42". 2-3307(6.1.) Top landing shall have 60" min. width when door swines onto the landine. with 24" on strike ;ide of door at eiterior ramp, or 18" at interior ramp. 2-3307(d. 1) k. Ramp handrails are required on each side of ramp, when slope exceeds 1 in 15. 2- 3307(e.1) 1. Ramp handrails shall be continuous, located 30"-34" in height above ramp surface, with 12" extensions beyond top and bottom and the ends returned. 2-3307(e.lj m. Handrails shall be 1-114" to 2" cross section, spaced minimum of 1-112" from wall. 2-3307(e.1) n. A 2" high curb or wheel guide rail centered 3" 5 1" above ramp surface is required on both sides where not otherwise bounded by walls when the ramp exceeds 10 feet in length. 2-3307(h.l) #SPWIAL ACCESS LIFTS 0! Lifts may be provided between levels, in lieu of elevator, when the vertical distance between landings, structural elevator, structural design and safeguards are aa allowed by the State of California, Department of Industrial Relations, Division of Occupational Safety and Health. 2-5107(a) . The lift platform shall be of sufficient size to accomodate a wheelchair (30"xw)"). 2-5107(a) d. There shall be a level and clear floor area or land- (60"x60") at each level for access to the lift. 2-5107(a) p. nA!LAFas . Provide 80" headroom from walkway ' 1 surface to any overtwphg obstruction. 2-3326(b) b. All required passage doors shall have 32" clear opening at 90 degrees (36'' door). 2-3304(f) C. At least one of a pair of doors shall meet the minimum 32" clear entrance width requirement. 2-3304( f) d. Threshold shall be no higher than 112" above the floor. Edge to be beveled with a slope no greater than 1 in 2, if more e. Exterior level landing may slope up to 114" per . foot in any direction for surface drainage. 2-413 f. Door hardware shall be of the lever or push type, mounted 30" to 44" above the floor and be operable with a maximum effort of 8.5 lbs. for exterior doors and - than 114". 3304(1.1) 5 lbs. for interior doors. 3304( i .2) 2-3304(c). 2- g. 3he lower 10'' of the door shall be of - smooth, plane surface (no recess or trap) except at automatic and sliding doors. 2-3304(1.3) n h. Building entrance(s) shall be identified by sign with the International Symbol of Accessibility. Show location on plan. The symbol shall be a vhite figure on blue background. 2-522(b) i. At turnstile, provide an access gate, 32" clear width opening, within 30 feet of turnstile. 2-3304(1.4) J. There shall be a clear area on each side of door, 60" deep in direction of door swing and 44" deep in opposite direction of door swing. 2-3304(1.1) V k. Width of clear area on the swing side of the door shall extend 24" past strike jamb for exterior doors and 18" past strike jamb for interior doors. 2-3304(i.l) sanitary facilities shall be made accessible to physically handicapped. (2-511.1(a)) 11. Doorways 'shall have 32" minimum clear opening width. 2-511.1 t. ?here shall be a level area with 60" clear depth in the direction of the door t' 1. The space between two consecutive doors (vestibule) shall provide a minimum of 48" clear depth between the open door and a second closed door.Doors in a series at a vestibule shall swine in the same direction, or away from 6e space between them. 2-3304(i.l) m. For corridors over 200 feet long, see special requirements of Sec. 2-3305(b)2. p' FLGORS Floors of a given story shall be a bco-n level throuphout or shall be connected by pedestrh ramps. passenger elevators, or s pecial access lifts. 2-522(e) / STAIRWAYS NUlX: Only applies where disabled access is provided or reqired to other levels. Treads shall have smooth, rounded exposed edges and be slip resistant. 2- 3306(s) Nosing shall not project more than 1-112 inches past face of the riser below. 2-3306(s) Risers shall be sufficiently solid. 2-3306(s) The upper approach and lower tread of each flight of stairs shall be marked with a contrasting colored strip 2" in width. 2-3306(r) On exterior stairs, tread shall be marked as noted above. 2-3306(r) Handrails are required on side of stairway. 2-3306 Handrails shall be located 30" to 34" above nosing,extend 12" beyond top riser and 12" plus tread width beyond bottom nosing and returned to walllnewel post. 2-3306(j .1). Handrails shall be 1-114" to 2" in gripping cross section ani of wall. 2-3306(j.l) 1-1/2" clear Approved stairway identification signs shall be located at each floor level in all enclosed stairways in buildings two or more stories in height. The sign shall identify the stairway, indicate whether there is roof access, the floor level, and the upper and lower terminus of the stairway. The information shall be presented using raised Arabic numerals and raised braille symbols which conform to Section 522(b)3. The sign shall be located approximately 5 feet above the floor landing immediately adjacent to the door on the strike side. Siens shall comply with requirements OZ U.B.C. Standard No. 33-2. , Doors (other than handitap compartment) are not to encroach more than 12" into above mentioned clear space. 2-511.l(a) . Provide a 28" clear space between water closet and fixture or 32" clear space between water closet and wall. 2-511.l(a) . A 48" long clear space is required in front of water closet. A 60" clear space is required when the toilet compartment has a side door. 2-511.l(a) . Water closet compartment door to provide 1 32" clear width for end entrv and 34" ' cleaz width for side entry. DLor to be self-closing. 2-511.l(a) to 19" above floor. 5-1502 I. Controls shall be operable with one hand, and shall not require tight grasping, pinching or twisting of the wrist. 5-1502 (:. Controls for the flush valves shall be mounted on the wide side of toilet areas, no more than 44" above the floor. 5-1502 #. The force required to activate controls . SINGLE ACCOMMODATION TOILEI FACILITIES . Water closet shall be located 28" from a fixture or 32" from a wall. 2-511.l(a) . Minimum clear space in front of water closet shall be 48". 2-511.l(a) . In an existing building, a single accomdation toilet facility may have a space 36" wide x 48 It long in front of water closet. 2-511.l(a) . One at side 42" long extending 24" in front of water closet; one at rear 36" long centered on water closet; both mounted 33" above floor. Where a tank- type toilet is used, grab bar may be as high as 36". 2-511.1(a) Bars shall be 1-114" to 1-112'' in diameter with 1-1/2" clearance to wall. 2-511.l(a) / . GRAB BARS AT WATER CLOSEX I". . Bar fasteners. and mounting support shall be able to withstand 250 1bs.lft. in bending, shear and tension. 2-511.i(a) p. WATER CLoSJrr . /URINALS - . Where urinals are provided, the rim of at B least one shall Droiect 14" from the wall and be 5-1503(a) located i7"- maximum above floor. I . The force required to activate the flush valve shall be 5 lbs. maximum and located 44" maximum above floor. 5-1503(b) . Provide 30" x 48" clear floor space for 4 forward approach. 2-511.l(b) Provide 30" x 48" clear floor space for forward approach. Said clear floor space may include knee and toe space under lavatory described below. 2-511.l(b) Provide clear space beneath lavatories 29" high by 30" wide by 8" deep at top and 9" high by 30" wide by 17" deep at bottom f;om front of lavatory ltoe space). The maximum counter surface height should be 34". 5-1504(a) Hot water and drain pipes under lavatories shall be insulated. 5-1504(b) Faucet controls and operating mechanism (operable with one hand) shall be of the tve not requiring tight grasping, pinching or twisting of the wrist (such as lever-operated) and an operating force not exceeding 5 lbs. 5-1504(c) If self-closing valves are used, they shall remain open for at least 10 seconds. 5-1504(c) )Jf. TOIIXI ROOM ACCESSORIES maximum above floor. 2-511.l(b) seat. 2-511.l(b) floor. 2-511.l(b) facilities the symbols to be provided are 12" Equilateral triangle for m, 12" diameter circle for women, and 114" thick, centered on door, 60" high and contrasting color. Unisex facilities shall be identified by the circle with the triangle su erimposed within the circle. 2-511.l(ap FACILITIES IDENTIFICATION /. On doorways leading to sanitary BATHING FACILITIES . One such facility shall comply when provided for the public, clients or employees. 2-511.1(a) . Shower compartment shall be 42" wide, 48" deep, with a 36'' wide entrance. 2-511.l(a) . Show on the plans that the handicapped bathing facilities shall conform to requirements of Sec. 2-511a-9, 5-1505 and 5-1506, i.e., folding seat, flexible shower hose, etc. -- Drinking fountains shall be within alcoves. The alcove shall be not less than 92" wide by 18" deep. When the enforcing agency determines that it would create an unreasonable hardship to locate the water fountain in an alcove, the water fountain may project into the path of travel, and the path of travel shall be identifiable to the blind as follows: (1.) The surface of the path of travel at the water fountain shall be textured so that it is clearly identifiable by a blind person using a cane. The minb textured area shall extend from the wall supporting the water fountain to 1 foot beyond the front edge of the water fountain and shall extend 1 foot beyond each side of the water fountain, or (2.) Wing walls shall be provided on each side of the water fountain. The wing walls shall project out from the supporting wall at least as far as the water fountain to within 6 inches of the surface of the path of travel. Also, there shall be a. midmum of 32 inches clear between the wing walls. I y' m1rnN-s 'EOUNUIN 2-511.l(c) .. - /PI, ING REpUIkS Aere kitchenettes are provided at employee break rooms, conference areas, customer lounges, etc., the faucet controls at kitchen sinks shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist (i.e., use lever- operated, push-type, etc.). If self- closing valves are used, they shall remain open for at least 10 seconds. 5-1508 QlaJP A WCllPARX i-b dAUDIT9RIUMS, ASSWLY HALLS, T"XEl, CIC. Seating and toilet facilities for the handicapped shall be accessible from the main lobby or primary entrance. 2-611(b) Note on the pla~ that drinking fountain shall conform to requirements of SeC. 2-511C and 5-1507. Provide space 30" x 48" for forward or parallel approach to telephone. f' 2-511.l(d) . Note on the plans that public telephone 1 shall conform to requirements of Sec. 2-511.1(6). @-cALw-s a. 15, 20 and 30 amp receptacle outlets shall be installed not less than 12" above floor. 3-210-50(e) b. Center of switches shall be located not less than 36" nor more than 48" above the floor. 3-380-8(c) * This structure requires wheelchair seating spaces. In theaters and auditoriums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices. 2-611(b) Each wheelchair space shall be 60" x 30" and level. 2-611(b) When the seating capacity exceeds 300, the wheelchair spaces shall be in more than one location. 2-611(b) This structure requires seats for semi-ambulant persons. Clear leg space shall be at least 24". 2-6ll(b) Stages, enclosed and unenclosed platforms, orchestra pits, ticket booths, and refreshment sales facilities shall be made accessible. 2-611(b) . STADIUMS, GRANDSTANDS, BlEACWXS, PAVILIONS, ~~ . This structure requires wheelchair seating spaces. In theaters end auditoriums, the seating shall be provided in a variety of locations SO as 1 to provided a choice of admission prices. . I 2-6ii.(c) When the seating capacity exceeds 300, the wheelchair spaces shall be in more than one location. 2-611(c) . Ticket booths must be accessible from both sides. 2-6ll(c) . Participation areas such as ball courts, exercise rooms, tracks, and clubrooms must be accessible. 2-611(c) . Spectator and participant Sanitary and locker facilities nust conform to the requirements of Chapter 2-5. 2-611(c) I #. DINING, BANQUEJ! AND BAR FACILITIES t . Access shall be provided at primary . Wheelchair access shall be provided to type of functional entrances. 2-611(d) all areas vhere each activity occurs. 2-611(d) 4 4:. Provide wheelchair access to raised plafforms, choir rooms, choir lofts, performing areas and other similar areas. 2-611(e) . Assembly areas along with enclosed and unenclosed platforms and stages shall be made accessible. 2-611(e) . Sanitary facilities shall conform to the requirements of Chapter 2-5. 2-611(e) (8. . This facility requires wheelchair seating spaces. 2-611(d) for male or female customers, one for each type shall be usable by the physically handicapped. 2-712(b) 1. Minimum dimension of room shall be 60" x 60". 2-712(b) within 20" of the floor. greater than 48" from the floor. 2-712(b) I~. Bottom of the mirror shall be located <. Height of clothing hooks shall not be 2-712(b) . At least one wheelchair seating space shall be provided for each dining, banquet and bar area. 2-611(d) . Access to wheelchair seating spaces shall be provided by 36" minirmrm clear width main aisles. 2-611(d) . Cafeteria line aisles shall be a minimum of 36" clear width. 2-611(d) . Access to food preparation areas shall comply with provisions for entrance doors and doorways contained.in Section 2-3304. 2-6ll(d) Restrowis and powder rooms shall conform ' to the requirements in Section 2-511. 2-611(d) . . Sanctusry areas shall be accessible. 2- 7 6ll(e) . Provide wheelchair seating Use Section 2- spaces in the sanctuary. 6ll(b). 2-6ll(e) t .- /A sign shall be posted in a prominent place indicating the availability of assistive-listening devices. The sign shall include the international symbol of deafness and wording that states "Assistive-listening System Available". GROUP B OCCLlPAKX iv, JGroup B occupancies used for assembly but having an occupant load of less 50 shall conform to all the requirements for Group A occupancies covered in Section 2-611. 2-712(d) {SALkS FACILITIES General sales, display and office areas together with related toilet rooms must be accessible. 2-712(b) Sales employee work stations shall be located on accessible levels. bployee work areas shall be accessible to employees in wheelchairs, and the customer side of sales or checkout stations shall be accessible. 2-712(b) This facility requires check stands accessible to the physically handicapped, based upon. 1 for 8 checkstands or less, 2 for 9 or more. 2- 712(b) Where quick check stands are provided, at least one shall be accessible. 2-712(b) Check stands shall be made accessible by providing a 36" aisle on the customer side of thb stand. 2-712(b) Accessible check stands shall be identified by the International Symbol of Accessibility and shall state, "This check stand to be ODM at all ths for handicappedlphysicaliy customers". 2-712(b) disabled '. :* '1 QPJUP E oc(IIpAAcp 5-S. . Accessible sanitation facilities in all Group H Occupancies shall be provided as specified in Chapter 2-5. 2-913(a) "I b. Accessible floors and levels shall path of travel to the specific area shall be accessible to the handicapped persons. Compliance must be shown, beginning from the existing parking area and leading to the area of alteration. 1. Existing restrooms, water fountains, and public telephones which serve said specific area at be shown to be comply with the requirements specified in Chapter 2-5. 2-913(a) . Employee work areas shall be accessible 1 by means of a 36-inch minim aisle width, and a 32-inch minimum clear opening door width. 2-913(a) accessible to and functional for handicapped persons. I . Information regarding handicapped accessibility shall be posted in lobby per Sec. 2-522. t 12/29/89 Datei 4- 5 J;risdiction G,-k b& Prepared by1 VALUATION AND PLAN CHECK FEE &&L- 0 Bldg. Dept. 0 Esgil PLAN CHECK NO. 90- 13-70 BUILDING ADDRESS /L& 0 Auk5 CfP =if- StI6Ti k APPLICANT/CONTACT GEL^^^ ftP G,, PHONE NO. TYPE OF CONSTRUCTION' CONTRACTOR PHONE BUILDING OCCUPANCY 469-9oz2 DESlGNER PHONE Plan Check Fee S $ 272.35 C 0 M ME NTS; 0 'I I! '9 1 * 12 SN TD cc HH DATE: 7 -1f-q BUILDING PLANCHECK ENGINEERING CHECKLIST EE cc KK do 0 do 0 do 0 E LEGAL REOUIREMENTS C K Site Plan TE IT,.J COP.. PLANCHECK NO. '70 -1370 0 ITEM INCOMPLETE - NEEDS YOUR ACTION LITEM SELECTED 3 /ob0 Aur 0 Pkm-g&B 7- 77 1. Provide a fully dimensioned site plan drawn to scale. Show: north arrow, property 1 ines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width and dimensioned setbacks. 2. Show on site plan: Finish floor elevations, pad elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes, driveway with percent (%) grade and drainage patterns. 3. Provide legal description and Assessors Parcel Number. giscretionarv ADDrOVal ComDliance D(_ 4. No Discretionary approvals were required. 5. Project complies with all Engineering Conditions of Approval for Project No. 6. Project does not comply with the following Engineering Conditions of Approval for Project No. Conditions complied with by: Date: Field Review - 7. Field review completed. No issues raised. with the site plan were found: A. 8. Field Review completed. The following issues or discrepancies Site lacks adequate public improvements. B. Existing drainage improvements not shown or in conflict with site plan. C. 0. Site is served by overhead power lines. Grading is required to access site, create pad or provide for ultimate street improvement. FRMOOlO . DH 08/29/89 E. Site access visibility problems exist. Provide onsite F. Other: turnaround or engineered solution to problem. Dedication Reaui rementt x 9. No dedication required. 10. Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 84" x 11" plat map and submit with a title report and the required processing fee. All easement documents must be approved and signed by owner(s) prior to issuance of Buildinq Permit. The description of the dedication is as follows: Dedication completed, Date: By : Imorovement Reauirements y. 11. No public improvements required. SPECIAL NOTE: Damaaed or defective imDrovements found ad. iacent to buildina site must be repaired to the satisfaction of the Citv inspector Drior to occuoa ncv. 12. Public improvements required. This project requires construction of pub1 ic improvements pursuant to Section 18.40 of the City Code. Please have a registered Civil Engineer prepare appropriate improvement plans and submit. for separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. The required improvements are: Improvement plans signed, Date: By : FRMOOIO .DH 08/29/89 13. Improvements are required. Construction of the public improvements may be deferred in accordance with Section 18.40 of the City Code. Please submit a letter requesting deferral of the required improvements together with a recent title report on the property and the appropriate processing fee so we may prepare the necessary Future Improvement Agreement. The Future Improvement Agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future Improvement Agreement completed, Date By : Sradina Reau i remen ts 13a. Inadequate information available on site plan to make a determination on grading requirements. Please provide more detailed proposed and existing elevations and contours. Include accurate estimates of the grading quantities (cut, fill, import, export). A14. No grading required as determined by the information provided on the site plan. -15. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted for separate plan check and approval through the Engineering Department. NOTE: The Gradina Permit must be issued and aradinq substantiallv comDlete and found acceDtable to the Citv InsDector orior to issuance of Buildino Permits. Grading Inspector sign off. Date: By : Mi scell aneous Permits 216. Right-of-way Permit not required. - 17. Right-of-way Permit required. A separate Right-of-way Permit issued by the Engineering Department is required for the following: -18. Ll9. Sewer Permit is required. A Sewer Permit is required The fee required Sewer Permit is not required. concurrent with Building Permit issuance. is noted below in the fees section. Industrial Waste Permit is not required. - 20. FRMOOlO .OH 08/29/89 221. Industrial Waste Permit Is required. Applicant must complete Industrial Waste Permit Applicantion Form and submit for City approval prior to issuance of Building Permits. Permits must be issued prior to occupancy. Industrial Waste Permit accepted - Date: By : Fees Reouird 4422. Park-in-Lieu Fee Total Fee: a!- - - Quadrant :- Fee per Unit: - 23, Traffic Impact Fee d Total Fee: /86.00 - Fee Per Unit: *24. Bridge and Thoroughfare Fee &25. Public Facilities Fee required. &26. Facilities Management Fee Zone: - Fee: 227. tJ&-28. Sewer Later 1 required: &u&G.h Fee per Unit: - Total Fee: d-&.m Sewer Fees Permit No. SE900//6 EDU’s .85 €DO Fee: @/O@ 2!= Fee: 6 1 REMARKS: A!! To SO&IT An) /MOOSTZ&L W&TE 17 WUC~~GJ* I ENGINEERING AUTHORIZATION TO ISSUE PERMIT FRMOOlO .DH 08/29/89 PLANPJINGCHEcXIJST Plan Check N . @- 1370 Address lo60 AcrX, W?&L'=&PN: 21 1-080-2, 3 Planner L+J& Phone 438-1161 Type of Project and Use 7;hw I 1 YPmJBemJT (Name) Zone c-24 Facilities Management Zone 4 "" YY 2 'I bb. Item Complete Item Incomplete - Needs your action 1,2, 3 Number in circle indicates plancheck number where deficiency was identified F.uvhmmental Review Required: YES - NO & TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Discretionary Action Required: YES - NO APPROVAWRESO. NO. DATE: PROJECT NO. OTHER RELATED CASES: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval TYPE coastal: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval YES - NO A DATE OF APPROVAL: LanclscapePlauRequired: YES-NOL See attached submittal requirements for landscape plans Site Plan: 1. Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property hes, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimensioned setbacks. Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and driveway. 2. do 0 &a 0 3. Provide legal description of property. do 0 4. Provide assessor's parcel number. zwing: mho 1. Setbacks: @,<f$K Front: Required Shown Int. Side: Required Shown Street Side: Required Shown Rear: Required Shown UhOA+ 2. Lot coverage: Required Shown 0/6 0 NIP 3. Height: Required Shown 4. Parking: Spaces Required Shown Guest Spaces Required - Shown rfl do0 QbL Additional comments and remarks have been made on the building plans. These marked-up plans may be picked up at the Building Department. These marked-up plans must be resubmitted with the revised plans for this project. Have plans been marked up? YES - NO 5 0 0 0 Additional Comments \ OK TO ISSUE /+- DATE L 9-3- Po - c: DataEntry PLNCK.FRM 2580 ORION WAY eitp of CarWaab PAGE1 OF1 1 CARWAD, CA 82008 TELEPHONE (818) 931-2121 - I FlRE DEPARTMENT DISAPPROVED I - PLAN CHECK REPORT PROJECT Bh ne.k L/1zu 4-41 e IL ADDRESS ARCHITECT ADDRESS PHOFE OWNE AUAT/?Ca I @o ADDRESS^^^/ fnAL1c #fSn/LQ3%ONp' L31 STORIES - 23Yq h, TOTALSQFT. p?qog * @SPRINKLERED WENANT IMP. APPROVAL OF PUNS IS PREDlCAmD ON CONFORIYWQ TO THE FOLLOWNO CON- AND/OR MAKWG THE FOLLOWNQ CORRECTIONS PLANS, SPECIFICATIONS, AND PERMITS Provide one copy of: floor plan(s); site plan; sheets Provide two slte plans showlng the locatlon of all exlstlng fire hydrants within 200 feet of the project. .I __ 1. - 2. - . Pfwlde speciflcatlons for the followlng: A. Permlts are required for the installatlon of all flre protection stand plpes, dry chemlcal, halon, Cor, alarms, hydrants). Plan must be approved by the fire - 5. The buslness owner shall complete a building lnformatlon letter and return it to the flra department. FIRE PROTECTION SYSTEMS AND EQUIPMENT /a ) fire aprlnklen (Design Crlterla: A 5 p.f& A/f/8 fire protection systems are required: 0 Dry Chemical, Halon, COz(Locati0n: ) 0 Stand Plpes (Type: ) ~ 0 Flre Alarm (Typetbocatlon: 1 v 1 2 7. Flr xtlngulaher Requirements: &e *A rated ABC ex lngulsher for each /oonn aq. ft. or poqlon thereof wlth a trdvehdls, ancd to the nearest &extingulsher wlth a minlmum ratlngof .?A be located id 5 ik?p bK tlngulsber net to &e& 75 feet of travel. 0 Other: Addltlonai flre hydrant@) shall be provlded - 8. A, Exit doors shall be openable from the inslde without the uae of a k8y or my spselai knowledge or effort. k0. A sign statlng, " This door to remaln unlocked durlng buslness hours" shall be placed above the maln exltuc -11. EXIT signs (6' x %" letters) shall be placed over all required exihs and directional slgns located as necessary to A. Storage, dlspensing or use of any flammable or combjlstlble liquids, flammable liquids, flammable gases and hazardous chemlcals shall comply wlth Unlform Flre Code. -13. Buildlng(s) not approved for hlgh plled combustible stock. Storage In closely packed piles shall not exceed 15 feet in helght, 12 feet on pallets or In racks and 6 feet for tires, piastlcs and some flammable liquids. If hlgh stock pll- Ing is to be done, comply wlth Uniform Fire Code, Artlcle 61. EXITS &Dau clearly Indicate the location of exlt doors. QEN6RAL , - 14. Addltlonai Requlrements. ~~ ~ ., .,, -15. Comolv wlth regulations on attached'sheet(s). -. .. - ,. * D.1. 6 . . D&t& 5 \.<. , Plan Exmnilnr j \, -Attach to Plans - Report malled to architect -Met wlth .. .~ , . k.'" Citv of Carlsbad Chris Smith ENCINA WATER POLLUTION CONTROL FACILITIES 6200 Avenida Enchas Carlsbad, CA 92009 INDUSIWAL WASX PERMIT APPLICATION NO. 754 Enclosed is a copy of the application for an Industrial Waste Discharge Permit from the subject applicant. Your review and recommendation on this application will be appreciated prior to the issuance of a waste disposal permit. LLOYD B%UBBS b City Engineer LBH:n Enclosure: Application N0.u 90 . r37D c: Building Department Ernie Femer, Department of Public Works Arnie Wing, Department of Health Services 2075 Las Palrnas Drive Carlsbad. California 92009-4859 (619) 438-1161 COM~ERCIAL/INDUSTRIAL APPLICATION FORM FOR INDUSTRIAL WASTE DISCHARGE PERMIT - CITY OF CARLSBAD APPL IC-EH 1’ BUILDING P.C. NO.: qD 1576 INDUSTRIAL CLASS: 134 APPLICATION NO.: 754 DATE: /0./7.90 A. e. C. APPLICATION FOR INDUSTRIAL WASTE DISCHARGE PERMIT GENERAL : WASTES AND PROCESSING: IZt/60mestic Waate Only 1-1 - Industrial Waste 1-1 - Industrial Waste NOT GENERAL DESCRIPTION OF WASTE (Chemical and Physical Characteristics of proposed waste): (Check there applicable) Discharged to Sener Discharged to Sewer PROCESS (If Applicable): WASTES 10s DISCHARGED TO SEWER: WASTE: TREATED: (Check One) UNTREATED: QUANTITY: AVERAGE GPO (Daily) MAXIMUM CPD (Gallons Per Day) J. WILLIAM COX. M.D.. Ph.0. omicron DEPARTMENT OF HEALTH SERVICES IS^ la-1137 1700 CAcl?lC UIG~WAV. aAN DICGO. CAUCORNIA e2101.2ll7 STEVEN A. ESCOEOU ASSlSTIIIT OIIeCtOn imm xa&mza HAullwus MTERW QuEsTImIw I Business Name nlelr\e,Kc~SI"~J*tIC\UFFLcQ - lhiling Address G 7 8 /-/,ccs.,de I~EPACC I 060 ft&ce~teeCode-t-St~t Site Address Telephone enn15 flonte~ 758 76.37 zip Zip 7R Contact Person 3 720B"/ I(?; city dJ+/?- tit LA R1.5 6Ad ?a008 u horized Agent I declare under penalty of perjury that to the best of my knowledge and belief the response5 (PDate --, rude herein are true and correct. Estab. I [ ] WPP Completed H b' Reviewed By Date Reviewed By Date BUILDING INSPECTION OEPT PL4N FILE NUMER Init.- Distribution: Original and 1st COPY to DHS-"0. 2nd copy to Applicant. 3rd copy to City/County Plan Check c - r Briefly Describe Nature of the ed Business Activity: $;s-fA~c ~~JFFLQRs RRkeS SAN DIBGO AIR POLLUTION CONTROL DISTRICT 9150 CHESAPEAKE DRIVE, SAN DIEGO, CALIFORNIA 92123-1095 (6191 69A-XW7 Indicate Permit Categories. . .- I AIR POLLUTION CONTROL QUESTIONNAIRE I Signature of Owner or Authorized Agent I declareundwpenattyaf perlvry that to the best of my knowledge and belief the Date rapanser made herea, am New State law, effective July 1.1989, (AB 3205, Chapter 1589. Statues 1988) requires that an applicant for building permit provide information indicating whether a permit is required from the Air Pollution Control District. This law further prohibits a City or a County from issuing Certificate of Occupancy unless a business has complied with provisions of the law that are administered by the Air Pollution Control District. The new law also imposes additional permitting requirements for a facility within 1,000 feet of the outer boundary of a school (K thru 12). To determine whether your business & subject to these new requtmnents, please complete this quesnonnajre. Building Inspcdon Plan File No: Infials- Mailing Address City State Zip Street Address of Proposed Facility City Zip b-~ 8 d,L( s~diPRr+AC-t d,SS4 cr+ 9row - -/ 1. Will the intended occupant install or use any of the equipment listed on the Listing of Air Pollution conttol District Permit Categories. (IF ANSWER TO 1 IS YES, APPLICANT MU= CONTACT THE Apu) DIRECTLW 0 2. (Answer only if the answer to 1 above is YES) Wm the subject facility be located wthm 1OW feet of the outer boundary of a school (K thru 12) as listed in the current Directory of School and Community College Districts, published by the San Diego County Omce of Education and the current California Private School Directory, compiled in accordance with provisions of Education Code Section 33190. AYCD use only STATUS: APPROVED FOR ISSUANCE EXEMPT FROM APCD OF BUILDING PERMIT, BUT APPROVED FOR OCCUPANCY PERMIT REQUIREMENTS NOT FOR OCCUPANCY Confirmin Stam Confirmin Stam Confirming Stamp TITLE 24 REPORT FOR: MEINEKE MUFFLER CAR COUNTRY PLAZA BLDG A CARLSBAD , CALIF. r .. .. PROJECT DESIGNER: RICK MARRS INC, OWNER: REPORT PREPARED BY: HERZBERGER/SALEHI ENG SAN DIEGO, CALIF. 92101 303 A ST. (619)239-4636 Job Number: C844 ' . Date: 9/18/1990 The COMPLY 24 computer program has been used to perform the calculations summarized in this compliance report. This program has interim approval and is authorized by the California Energy Commission for use with the Second Generation Nonresidential Building Energy Efficiency Standards for Nonresidential Occupancies. Second Generation Residential Occupancies shown to comply with this program conform to the results produced by the Public Domain Point System, developed by the California Energy Commission. This program developed by Gabel Dodd Associates (415) 428-0803.