Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1060 CHINQUAPIN AVE; ; CB122165; Permit
11-08-2012 City ©f Carisbad 1638 Faraday Av Carlsbad, CA 92Q08 MssceHaneous Permit Permit No: CB122165 Building Inspection Request Line (700) 602-2725 Job Address Permit Type. Parcel No' Valuation Reference #; PC# Ptoject Title Applicant TERRY MONTELLO 1060 CHINQUAPIN AV CBAD MISC Subtype 0000000000 Lot #' $0 00 REPAIR 0 LIME GROVE ARTS • FIRE DAMAGE INCLUD STRUCTURAL MEMBERS, ROOF FRAMING, Owner: Status Applied Entered By. Plan Approved Issued' Inspect Area. ISSUED 10/22/2012 JMA 11/08/2012 11/08/2012 4715 BOTH ST SAN DIEGO CA 92115 619-994-5557 Misceteneous Fee #1 Miscelaneous Fee #2 Additional Fees TOTAL PERMIT FEES NSPECTION FEE PLAN CHECK FEE $260.00 S187.50 $0,00 $447 50 Total Fees. $447 50 Total Payments To Date-$447 50 Balance Due: $0.00 inspector FINAL APPROVAL Date. J^dMJS.-Clearance NOTICE Pleass take NOTICE that approval ot your project inoiudes ttie Impositien" ot fees, dedications, lesorvatlons, or ottier exactions hereafter ooHsciively ifcferred to as "fess/exaotions," You have 90 days from the date this permit was issued to protest imposition of these foes/exactions, It you protest them, you must follow the protest piocedures set forth in Government Code Section 66020(a), and tile the'protest and any other required Information with the City Managei for processing In accoidanco with Carlsbad Municipal Code Section 3.32 030 Failure to timely follow tliat procedure will bar any suDsequem legal action to attack, review, set aside, void, or annul their imposition You are heieby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT .^PPLY to water and sewer connection fees and capacity changes, nor penning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any tees/exaciions of which you have previously been given a NpTiQE simllai to (his, or as to which the sfgtute of limitations has previously otherwise expired THE FOLLOWING APPROVALS REQUIRED PRIOR TO P05MIT tSSUAKCE: • PUNNING • ENGINEERING • BUILDING QFIRE • HEALTH • HAZMAT/APCD ^ CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: buiclling@carlsbadca.gov www carlsbadca gov Plan Check No. CT^IZ' 2-^1 C£?S~ Est. Value Plan Ck. Deposit Date iOt^i^ SWPP SUITE#/SPACE((/UNIT# APN ^^-v^ CT/PROJECT # LOT# ^JiHASE* 1 # OF UNITS |# BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR TYPE OCC GROUP DESCRIPTION OF WORK: /nclude Square Feet of Affected/treafsj /" \ -^^fvL^ fDC^P ^Ki2,C^bU^Yt^ "too? "ifU,^^ l+mAJtor \PQMV^% EXISTING USE ' PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS YES • # NO • YES • NO • YES • NO • APPUCANT N.M. <P.... Co„tac.-T^ ^ m/3rfi^J?Jln APPLICANT NAME (Secondary Contact) ADDRESS ^ ^ C 4- ^ ADDRESS CITY STATE ZIP 'PHONE , ~__ 'AX PHONE FAX EMAIL PROPERtY OWNER NAME 1 »^ „ /I A * /\ /> LxtYJL 4\f70LAjl /V^4J. CONTRACTOR BUS NAIVIE -. • 1 / /-^ \ ADDRESS ^ " ' /\ ' I ADDRESS , ^ _ N^^*J- PHONE =AX FAX EMAIL EMAIL ARCH/DESIGNER NAME & ADDRESS STATE LIC # applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Lav» (Criapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects tne applicant to a civil penalty of not more than five hundred dollars i$500)) and policy Workers' Compensation Declaration / ftereJiy affirm under penalty of perjury one of the following declarations O I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued ^~STH(ave and will maintain workers' compensation, as required by Section 3700 of the Labm£o<te, for the perfomiance of the workjopshich this pennit is issued^My workers' compensation msjirancj / number are Insurance Co; -ryXi' \^.rO ekM^ PH- PoliovNoUrr.?.^.^-^^.- '^ZS ExoiratonDate This section need not be completed itt[)gjiarmrt 13 tor^fle hundred dollars ($100) or less O Certificate of Bjelffptibn^^SOTy that in the performSRce of the work for which this perniit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARING Faili(reto s^re workers' compeKsatiop.eeTersge^s unlawful, and shall subject an einployerto criminal penalties and civil fines u|| to one h/lndred thousand dollars (&100,000), in ict earner ar 4s addition to the con of compen^ation^dih CONTRACTOR'SiaiiATURE" jages as provided for of the Labor code, interest and attomey's fees GENT DATE / tieteby affirm that I am exempt Confracfor's License Law for fhe following reason O I, as owner of the property or niy5ni(jluyueSwith wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) • I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) • I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and matenals for construction of the proposed property improvement O Yes • No 2 I (have / have not) signed an application for a building permit for Ihe proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone /contractors' license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supen/ise and provide the major work (include name / address / phone / contractors' license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work) yfifPROPERTY OWNER SIGNATURE •AGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous matenals registration form or nsk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Acf • Yes • No Is the applicant or future building occupant required to obtain a pemiit from the air pollution control distnct or air quality management district • Yes • No Is the facility to be constnicted within 1,000 feet of the outer boundary of a school site'' • Yes • No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that ttiere is a constmction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name Lender's Address I ceili^ ttiatlhaveneadtheapplicabonandstatethatthe above information is conect and that the infeimation on the plans is accurate I agree to comply with all City onlinances and State lans lelabng to building constmction I hereby authorize representative AGAINST ALL LIABILITIES, OSHA An OSHA perniit IS EXPIRATION Every pemiit 180 days from the date of si enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD COSTS AND"^PENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMfT excavations over 5'0' d^ep and demoUion or constmction of structures over 3 stones in height ithe provisions of this Code shall expire by limitation and become null and void rf the buikiing or viork authonzed by such perniit is not commenced within ithonzed by such perniit is suspended or abandoned at any time after the work is commenced tor a penod of 180 days (Section 106 4 4 Unifomi Building Code) STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY If a Certificate of Occupancy will be requested at final inspection. OCCUPANCY ! m e r c i a I Fax (760) 602-8560, Email www buildina(5)carlsbadca gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008 C0#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY Carlsbad CA PHONE FAX EIVIAIL OCCUPANT'S BUS LIC No DELIVERY OPTIONS n PICK UP: • CONTACT (Listed above) • OCCUPANT (Listed above) • CONTRACTOR (On Pg 1) • MAIL TO: • CONTACT (Listed above) • OCCUPANT (Listed above) • CONTRACTOR (On Pg 1) • MAIL / FAX TO OTHER: \ a ASSOCIATED CB#- • NO CHANGE IN USE / NO CONSTRUCTION • CHANGE OF USE / NO CONSTRUCTION ^APPLICANT'S SIGNATURE DATE Inspection List Permit#: CB122165 Date Inspection Item 04/18/2013 19 Final Structural 04/18/2013 89 Final Combo 04/16/2013 19 Final Structural 04/16/2013 89 Final Combo Type: MISC REPAIR Inspector Act Rl 03/04/2013 89 01/28/2013 18 01/28/2013 23 12/17/2012 17 12/12/2012 16 11/29/2012 84 11/19/2012 24 11/19/2012 44 Final Combo Exterior Lathi/Drywall Gas/Test/Repairs Interior Lath/Drywall Insulation Rough) Combo Rough/Topout Rough/Ducts/Dampers MC MC MC MC MC MC MC MC MC MC Fl Rl PA CO AP AP AP AP AP CO CO LIME GROVE APTS.: FIRE DAMAGE INCLUD. STRUCTURAL MEMBERS, ROOF Comments SEE NOTICE FOR REMAINING CORRECTIONS NOTICE SOFFIT/WALL SECTIONS UNIT 16-1? UNIT 17 ONLY SEE CARD SEE CARD Friday, April 19, 2013 Page 1 of 1 EsGil Corporation In <Partnersliip with government for <BuiC<£ing Safety DATE: 10/30/2012 • APPLICANT •(<r[jRis> JURISDICTION: City of Carlsbad •>tAfrREVlEWER • FILE PLAN CHECK NO.: 12-2165 SET I PROJECT ADDRESS: 1060 Chinquapin Avenue PROJECT NAME: Fire Damage Repair Lime Grove Apartments 1^ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. n The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. Q The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. Q The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. [~] The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. r~| The applicant's copy of the check list has been sent to: /\ EsGil Corporation staff did not advise the a^Dplicant that the plan check has been completed. J I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person • REMARKS: By: David Yao Enclosures: EsGil Corporation • GA • EJ • PC 10/25 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858)560-1468 • Fax (858) 560-1576 City of Carlsbad 12-2165 10/30/2012 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: David Yao PLAN CHECK NO.: 12-2165 DATE: 10/30/2012 BUILDING ADDRESS: 1060 Chinquapin Avenue BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING PORTION AREA { Sq. Ft.) Valuation Multiplier Reg Mod. VALUE ($) fire damage repair Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code Cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review n Repetitive Fee Repeats • Complete Review • Other • Hourly EsGil Fee Based on riourly rate $187.50 • Structural Only 1.5 $100 00 Hrs. $150.00 Comments. Sheet 1 of 1 macvalue doc + PLANNING DIVISION Development Services Planning Division BUILDING PLAN CHECK Development Services Planning Division CITY OF APPROVAL 1635 Faraday Avenue P-29 (760) 602-4610 www carlsbadca eov DATE: 10/23/12 PROJECT NAIVIE: ROOF REPAIR (FIRE DAMAGE) PROJECT ID: PLAN CHECK NO: CB122165 SET#: ADDRESS: 1060 CHINQUAPIN AV APN: ^ This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required DYes ^ No Vou may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit Resubmitted plans should include corrections from all divisions. Q Tliis plan clieck review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: permits@cox.net For questions or clarifications on the attaclied checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 I 1 Chris Sexton 760-602-4624 Chrls.Sexton@carlsbadca.2ov Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.eov Greg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov 1 1 Cindy Wong 760-602-4662 Cvnthia.Wons@carlsbadca.gov • • 1 1 Dominic Fieri 760-602-4664 ' Dominlc.Fieri@carlsbadca.gov Remarks: CERTIFICATE OF COMPLETION Member INSTALLATION OF INSULATION RETROFIT The undersigned certifies that insulation has been installed at the stated location to the specifications below: Date of Installation Completion: ^^^^^^^ ^ Place of Installation (owners name): AddreSStSlOSPICHlNQUAEINjAVE #8, 16,fl5^8 Ci^; CARLSBAD Description of Installation FIBERGlJ^SS BATTS Ceilings Bates: Type of Material: Manufacturen JOHNS MANVILLE Thickness:. R-Value: _ 10" R30 Initial Installed Thickness: ir Minimum Settled Thickness: _ Number of Bags Used: 28 R-Value: R30 Coverage Area: I875SQFT Exterior Waiis Type of Material: FIBERGUSS BATTS Manufacturen JOHNS MANVILLE Thickness: 31/2" R-Value: R13 Coverage Area: 36o so FT Floors Type of Material: Manufacturer: Thickness: R-Value: Coverage Area: State; CA . Zip: Crawlspace Type of Material: Manufacturen _ Thickness: R-Value: Coverage Area: 925 so FT Blown: Type of Material: FIBERGLASS ATTIC BLOW Manufacturen JOHNS MANVILLE CLIMATE PRO Coverage Area: OUier Areas fspecifyl TITLE 24 AIR INFILTRATION Type of Material: Manufacturer Thickness: R-Value; Coverage Area: ICAA iVIember Insulation Contractor Company Name: J & L insulation, Inc. License No.: 472996 Street Address: City: Lakeside 10035 Maine Ave. State:CA_Zip:92040_ Company Representative Print Name: JohnJ. Kellman Signature:. Date:, 12/11X1 BUILDING ENERGY ANALYSIS REPORT PROJECT: Lime Grove Apts. Unit #17 (Fire Damage Repair) 1060 Chinquapin Ave Carlsbad, CA 92008 Project Designer: IVIJ Structural Engineers 7710 Balboa Ave, Suite 206-C San Diego, CA 92111 858-442-7771 Report Prepared by: David Schneider (CEA & CEPE) Title 24 Energy Consultants P.O. Box 711307 San Diego, CA 92171 619-504-5610 Job Number: 12-202 Date: 10/12/2012 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards This program developed by EnergySoft, LLC - www energysoft com. EnergyPro 5 1 by EnergySoft User Number 1562A RunCode: 2012-10-12712:35:0 ID 12-202 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1R Mandatory Measures Summary 8 HVAC System Heating and Cooling Loads Summary 11 Room Load Summary 12 Room Heating Peak Loads 13 Room Cooling Peak Loads 14 •k-r EnergyPro 5 1 by EnergySoft Job Number ID 12-202 User Number 1S62A PERFORMANCE CERTIFICATE: Residential (Part 1 of 5) CF-1R Project Name Lime Grove Apts. Unit #17 (Fire Damage F Building Type • Single Family • Addition Alone H Multi Family 121 Existing+ Addition/Alteration Date 10/12/2012 Project Address 1060 Cliinquapin A ve Carlsbad California Energy Climate Zone CA Climate Zone 07 Total Cond Floor Area 931 Addition 0 # of stories 2 FIELD INSPECTION ENERGY CHECKLIST • Yes • No HERS Measures - If Yes, A CF-4R must be provided per Part 2 of 5 of this form. • Yes • No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity {ff) Features (see Part 2 of 5) Status Wall Wood Framed R-13 458 Altered Door Opaque Door None 20 New Roof Wood Framed Rafter R-19 931 Altered FENESTRATION u-Exterior Orientation Areaiff) Factor SHGC Overiiang Sldeflns Shades Status Front (S) 58 0 0 710 0 73 none none Bug Screen Removed Front (S) 58 0 0 390 0 37 none none Bug Screen New Rear(N) 30 0 0 710 0 73 none none Bug Screen Removed Rear(N) 30 0 0 710 0 73 none none Bug Screen Removed Rear(N) 60 0 0 390 0 37 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status Central Furnace 80% AFUE No Cooling 13 0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status FAU System (Unit #17) Ducted Ducted Attic, Ceiling Ins, unvented 42 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5 1 by EnergySoft User Number 1562A RunCode: 2012-10-12712:35:09 ID 12-202 Page 3 of 14 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1R Project Name Lime Grove Apts. Unit iti 7 (Fire Damage R Building Type • Single Family 0 Multi Family • Addition Alone 12! Existing+ Addition/Alteration Date 10/12/2012 SPECIAL FEATURES INSPECTION CHECKLIST Ttie enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that othera/ise complies based on the adequacy of the special justification and documentation submitted The HVAC System Goodman G!\/IS80403AXA does not include a cooling system, field venfication is not necessary HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. EnergyPro 5 1 by EnergySoft User Number 1562A RunCode: 2012-10-12712:35:09 ID 12-202 Page 4 of 14 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1R Project Name Lime Grove Apts. Unit #17 (Fire Damage Re Building Type • Single Family 13 Multi Family • Addition Alone Q Existing+ Addition/Alteration Date 10/12/2012 ANNUAL ENERGY USE SUMMARY standard Proposed Margin "•"^^ (kBtu/ft^-yr) Space Heating 4 94 3 14 1 79 Space Cooling 18 62 11 12 7 50 Fans 6 65 4 42 2 23 Domestic Hot Water 0.00 0 00 0 00 Pumps 0 00 0 00 0 00 Totals 30.21 18 68 11 52 Percent Better Than Standard: 38 2% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Building Front Orientation: Number of Dwelling Units Fuel Available at Site: Raised Floor Area: Slab on Grade Area: Average Ceiling Heighit: Fenestration Average U-Factor: Average SHGC: (S) 180 deg 1 00 Natural Gas 0 0 8 1 0 39 0 37 Ext. Walls/Roof (S) (W) (N) (E) Roof Wall Area 298 0 298 0 931 TOTAL: Fenestration/CFA Ratio: Fenestration Area 58 0 60 0 0 118 12 7% REMARKS NOTICE THE TITLE 24 ENERGY LOAD ANALYSIS IN THIS REPORT IS FOR TITLE 24 ENERGY CODE COMPLIANCE PURPOSES FINAL SPECIFICATIONS AND SELECTION OF HVAC EQUIPMENT IS THE SOLE RESPONSIBILITY OF THE MECHANICAL ENGINEER OR INSTALLING HVAC CONTRACTOR THIS RESPONSIBLE PARTY SHOULD PERFORM BOTH MANUAL "D" AND MANUAL "J" CALCUATIONS FOR PROPER SIZING AND SELECTION OF MECHANICAL EQUIPMENT STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations 8307 The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company ™® ^'^ Energy Consultants Address PO Box 711307 City/State/Zip San Diego, CA 92171 Name ^^wcf Schneider (CEA & CEPE) Phone 619-504-5610 10/12/2012 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Structural Engineers Address ^^''^ Balboa Ave, Suite 206-C Name James A Miller City/State/Zip San Diego, CA 92111 pjione 858-442-7777 Signed License # Date EnergyPro 5 1 bv EnergySoft User Number 1562A RunCode: 2012-10-12712:35:0 ID 12-202 Page 5 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1R Project Name Lime Grove Apts. Unit #17 (Fire Damage Re Building Type • Single Family 21 Multi Family • Addition Alone • Existing+ Addition/Alteration Date 10/12/2012 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt status Joint Appendix 4 Location/Comments Surface Type Area U- Factor Cavity Exterior Frame Interior Frame Azm Tilt status Joint Appendix 4 Location/Comments Wall 220 0 102 R-13 780 90 Altered 4 3 1-A3 (E=4 3 1-A2) Existing Unit #17 Door 20 0 500 None 780 90 Removec 4 5 1-A4 Existing Unit #17 Door 20 0 500 None 780 90 New 4 5 1-A4 Existing Unit #17 Wall 238 0 102 R-13 0 90 Altered 4 3 1-A3 (E=4 3 1-A2) Existing Unit #17 Roof 931 0 051 R-19 90 72 Altered 4 2 2-A12 (E=4 2 2-A12 Existing Unit #77 FENESTRATION SURFACE DETAILS ID Type Area U-Factor' SHGC" Azm status Glazing Type Location/Comments 7 Window 40 0 0 770 Default 0 73 Default 780 Removed Double Metal Clear Existing Unit #17 2 Window 78 0 0 770 Default 0 73 Default 780 Removed Double Metal Clear Existing Unit #17 3 Window 40 0 0 390 NFRC 0 37 NFRC 780 New Milgard Classic Low-E Vinyl Existing Unit #17 4 Window 78 0 0 390 NFRC 0 37 NFRC 780 New Milgard Classic Low-E Vinyl Existing Unit #17 5 Window 24 0 0 770 Default 0 73 Default 0 Removed Double Metal Clear Existing Unit #17 6 Window 60 0 770 Default 0 73 Default 0 Removed Double Metal Clear Existing Unit #17 7 Window 60 0 770 Default 0 73 Default 0 Removed Double Metal Clear Existing Unit #17 8 Window 24 0 0 770 Default 0 73 Default 0 Removed Double Metal Clear Existing Unit #17 9 Window 24 0 0 390 NFRC 0 37 NFRC 0 New Milgard Classic Low-E Vinyl Existing Unit #17 10 Window 60 0 390 NFRC 0 37 NFRC 0 New Milgard Classic Low-E Vinyl Existing Unit #17 11 Window 60 0 390 NFRC 0 37 NFRC 0 New Milgard Classic Low-E Vinyl Existing Unit #17 12 Window 24 0 0 390 NFRC 0 37 NFRC 0 New Milgard Classic Low-E Vinyl Existing Unit #17 (1) U-Factor Type 116-A = (2) SHGC Type 116-B = Default Table from Standards, NFRC = Labeled Value Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Extenor Shade Type SHGC Window Hgt Wd Len Hgt LExt RExt Overhang Left Fin Dist Len Hgt Dist Right Fin Len Hgt Bug Screen 0 76 Bug Screen 0 76 Bug Screen 0 76 Bug Screen 0 76 Bug Screen 0 76 Bug Screen 0 76 Bug Screen 0 76 Bug Screen 0 76 Bug Screen 0 76 10 Bug Screen 0 76 11 \Bug Screen 0 76 12 Bug Screen 0 76 EnergyPro 5 1 by EnergySoft User Number 1562A RunCode: 2012-10-12712:35:09 ID 12-202 Page 6 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Lime Grove Apts. Unit #17 (Fire Damage Re Building Type • Single Family • Addition Alone ) IZl Multi Family IZI Existing+ Addition/Alteration Date 10/12/2012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area (fr") Volume Year Built System Name Zone Name New Existing Altered Removed Volume Year Built FAU System (Unit #17) Altered Unit #17 937 7,547 7980 'T Totals C 0 937 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff Cooling Type Mm Eff. Thermostat Type Status FAU System (Unit #17) 7 Central Furnace 80% AFUE No Cooling 73 0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Cooling Duct Location Duct R-Value Ducts Tested"? Status FAU System (Unit #17) Ducted Ducted Attic, Ceiling Ins, unvented 42 • New • • • • WATER HEATING SYSTEMS System Name Qty. Type Distnbution Rated Input (Btuh) Tank Cap. Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status CEC Standard MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length (ft) Add y2" Insulation System Name Pipe Length Pipe Diameter Insul. Thick. Control Qty. HP Plenum Outside Buned Add y2" Insulation System Name Pipe Length Pipe Diameter Insul. Thick. • • • • • EnergyPro 51 by EnergySoft User Number 1562A RunCode: 2012-10-12712:35:09 ID 12-202 Page 7 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3) MF-1R Project Name Lime Grove Apts. Unit #17 (Fire Damage Repair) Date 10/12/2012 NOTE Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1R-ALT Form) shall supersede the items marked with an astensk (*) below This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans Building Envelope Measures: §116(a)1 • Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage §116(a)4' Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of §10-111 (a). §117' Exterior doors and windows are weather-stnpped, all joints and penetrations are caulked and sealed. §118(a) Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(0 The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. *§150(a) Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor. §150(b) Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§150(c)' Minimum R-13 insulation in wood-frame wall or equivalent U-factor. *§150(d): Minimum R-13 insulation in raised wood-frame floor or equivalent U-factor. §150(f)" Air retarding wrap is tested, labeled, and installed according to ASTM £1677-95(2000) when specified on the CF-1R Form. §150(g) Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1) Water absorption rate for slab edge insulation matenal alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light detenoration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150(e)1 A' Masonry or factory-built fireplaces have a closable metal or glass door covenng the entire opening of the firebox. §150(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight-fitting damper and or a combustion-air control device. §150(e)2- Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited Space Conditioning, Water Heating and Plumbing System Measures: §110-§113' HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5 Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115' Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances (appliances with an electncal supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150(h)- Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i) Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater §150(j)1 B Unfired storage tanks, such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150(j)2- First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2' Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2 Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A §150(|)3A- Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind §150(j)3A Insulation for chilled water piping and refngerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space §150(|)4' Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 51 by EnergySoft User Number 1562A RunCode: 2012-10-12712:35:09 ID 12-202 Page 8 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3) MF-1R Project Name Lime Grove Apts. Unit #17 (Fire Damage Repair) Date 10/12/2012 §150(m)1 All air-distnbution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system that meets the applicable requirements of UL 161, UL 181 A, or UL 1818 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1 Building cavities, support platforms for air handlers, and plenums defined or constructed with matenals other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D- Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150(m)7 Exhaust fan systems have back draft or automatic dampers. §150(m)8 Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150(m)10' Flexible ducts cannot have porous inner cores. §150(o)- All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a) Any pool or spa heating system shall be certified to have- a thermal efficiency that complies with the Appliance Efficiency Regulations, an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1 - Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. §114(b)2- Outdoor pools or spas that have a heat pump or gas heater shall have a cover. §114(b)3- Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only dunng off-peak electric demand penods. §150(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p) Residential Lighting Measures: §150(k)1 - High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2. §150(k)3- The wattage of permanently installed luminaires shall be determined as specified by §130(d). §150(k)4. Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw-base socket. §150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). §150(k)7- All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8 A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION- Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 fts may be exempt from the 50% high efficacy requirement when- all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi-scene programmable control system; and all permanently installed luminanes in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual-on occupant sensor §150(k)9 Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnefgyPro 5 7 by EnergySoft User Number 1562A RunCode: 2012-10-12712:35:09 ID 12-202 Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3) MF-1R Project Name Lime Grove Apts. Unit #17 (Fire Damage Repair) Date 10/12/2012 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1 - Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual- on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2- Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150(k)11 §150(k)12. Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Undenwriters Laboratones or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling §150(k)13- Luminaires providing outdoor lighting, including lighting for pnvate patios in low-nse residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy EXCEPTION 1 Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an overnde or bypass switch that allows the luminaire to be always on EXCEPTION 2. Outdoor luminaires used to comply with Exceptioni to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3. Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no more than five watts of power as determined according to §130(d) §150(k)15- Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130,132,134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16. Permanently installed lighting in the enclosed, non-dwelling spaces of low-nse residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s) certified to comply with the applicable requirements of §119. EnergyPro 5 1 by EnergySoft User Number 1562A RunCode: 2012-10-12712:35:09 ID 12-202 Page 10 of 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lime Grove Apts. Unit #17 (Fire Damage Repair) Date 10/12/2012 System Name FAU System (Unit #17) Floor Area 931 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 32,000 Total Room Loads 330 6,989 662 162 8,440 Total Output (Btuh) 32,000 Return Vented Lighting 0 Output (Btuh/sqft) 34 4 Return Air Ducts 228 377 Cooling System Return Fan 0 0 Output per System 0 Ventilation 0 0 0 0 0 Total Output (Btuh) 0 Supply Fan 0 0 Total Output (Tons) 00 Supply Air Ducts 228 377 Total Output (Btuh/sqft) 00 Total Output (sqft/Ton) 00 TOTAL SYSTEM LOAD 7,445 662 9,193 Air System CFM per System 600 HVAC EQUIPMENT SELECTION Airflow (cfm) 600 Goodman GMS80403AXA 0 0 32,000 Airflow (cfm/sqft) 0 64 Airflow (cfm/Ton) 00 Outside Air (%) 00% Total Adjusted System Output 0 0 32,000 Outside Air (cfm/sqft) 0 00 (Adjusted for Peak Design conditions) Note: values above given at ARi conditions TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM HEATING SYSTEM PSYGHROMETRICS Alrstream Temperatures at Time of Heating Peal<) 34 °F 69 °F •=-•=- Outside Air 0 cfm 69 °F •4 69 "F • 119 °F Supply Fan Heating Coil 600 cfm 118°F ROOM X 70 °F COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 83 / 68 "F 75 / 62 °F 75 / 62 °F 55 / 54 "F Outside Air Ocfm 75 / 62"F •4 =• Supply Fan 600 cfm Cooling Coil 55 / 54 °F 46 6 % ROOM 75 / 62 °F EnergyPro 5 1 by EnergySoft User Number. 1562A RunCode: 2012-10-12712:35:09 ID 12-202 Page 11 of 14 ROOM LOAD SUMMARY Project Name Lime Grove Apts. Unit #17 (Fire Damage Repair) Date 10/12/2012 System Name FAU System (Unit #17) Floor Area 937 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Existing Unit #17 Altered Unit #17 7 330 6,989 662 330 6,989 662 762 8,440 1 PAGE TOTAL TOTAL * 330 6,989 662 762 8,440 PAGE TOTAL TOTAL * 330 6,989 662 762 8,440 * Total includes ventilation load for zonal systems EnergyPro 5 1 by EnergySoft User Number 1562A RunCode: 2012-10-12712:35:09 ID 12-202 Page 12 of 14 ROOM HEATING PEAK LOADS Project Name Lime Grove Apts. Unit #17 (Fire Damage Repair) Date 10/12/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Floor Area Indoor Dry Bulb Temperature Altered Unit #17 931 0 ft' 70 °F Time of Peak Outdoor Dry Bulb Temperature Jan 1 AM 34 °F U-Value AT''F X 0 7020 X 36 - X 0.3900 X 36 X 0 5000 X 36 X 0 0510 X 36 = X X = X X — X X - X X - X X - X X = X X - X X X X - X X - X X X X X X X X - X X - X X = X X X X = X X - X X X X — X X - X X X X - X X X X - X X = Conduction Area R-73 Wall Milgard Classic Low-E Vinyl Wood Door R-19 Roof 458 0 1180 20.0 931 0 Items shown with an astensk (*) denote conduction through an interior surface to another room Btu/hr Page Total 7,682 7,657 360 7,709 5,408 lnfiltratjon:[ 7 00 X 7 078 X 937 8 70 X 0 627 /60] X 36 3,032 Schedule Fraction Air Sensible Area Ceiling Height ACH AT TOTAL HOURLY HEAT LOSS FOR ROOM 8,440 EnergyPro 5 1 by EnergySoft User Number 1562A RunCode: 2012-10-12712:35:09 ID 12-202 Page 13 of 14 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Lime Grove Apts. Unit #17 (Fire Damage Repair) Date 10/12/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Altered Unit #17 Floor Area 931.0 ft' Indoor Dry Bulb Temperature 75 °F Outdoor Dry Bulb Temperature °^ Outdoor Wet Bulb Temperature 68 Outdoor Daily Range: ^'^ Opaque Surfaces Orientation Area U-Factor CLTD^ Btu/hr R-13 Wall (s; 220 0 X 0 7020 X 22 0 494 Wood Door (s; 20 0 X 0 5000 X 25 0 -250 R-13 Wall (N) 238 0 X 0 7020 X 73 0 -376 R-19 Roof (E) 937 0 X 0 0510 X 58 0 2,754 X X - X X - X X X X - X X - Page Total 3,873 Items shown with an asterisk (*) denote conduction through an intenor surface to another room 1 Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF NewWindow New Window New Window New Window New Window New Window (S) (S) (N) (N) (N) (N) 00 00 00 00 00 00 16 1 16 1 16 1 16 1 16 1 16 1 Area GLF Btu/hr 40 0 X 26 9 = 7,077 78 0 X 26 9 — 485 24 0 X 76 7 -387 60 X 76 7 97 60 X 76 7 -97 24 0 X 76 7 387 X — X X Page Total 2,530 Internal Gain Btu/hr Occupants Equipment 7 0 00 Occupants Dwelling Unit 230 7,200 Btuh/occ. Btu 230 Infiltration: 7 078 X 0 73 X Air Sensible 65 69 475 CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,989 Latent Gain Btu/hr Occupants 7 0 Infiltration: 4,834 0 73 Occupants X 200 Btuh/occ. 200 65 69 0 00799 462 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 662 EnergyPro 5 1 by EnergySoft User Number 1562A RunCode: 2012-10-12712:35:09 ID 12-202 Page 14 of 14