HomeMy WebLinkAbout1060 MAGNOLIA AVE; ; CB012754; Permit.1' • I City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit Permit No: CB012754
Building Inspection Request Line (760) 602-2725
1060 MAGNOLIA AV CBAD
RESDNTL Sub Type: SFD Status: ISSUED
2051912100 Lot #: 0 Applied: 08/21/2001
$248,278.00 Construction Type: VN Entered By: RMA
Reference #: Plan Approved: 10/10/2001
2 Structure Type: SFD Issued: 10/10/2001
5 Bathrooms: 4 Inspect Area: RCB
OGARA RES-2315 SF, 480 SF GAR Orig PC#:
438 SF 2ND DWELLING UNIT Plan Check#:
04-10-2002
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
Applicant: Owner:
OGARA MICHAEL D&VICKI B OGARA MICHAEL D&VICKI B 4774 04/10/02 0002 01 02
60-00 3200 JAMES DR
CARLSBAD CA 92008
3200 JAMES DR
CARLSBAD CA 92008
V
/ N
Total Fees $20,919.10 / Total Payments To Date: .$20,859.10 // Balance Due $60.00
Building Permit / $1,005.48 Meter Size . -
AddI Building Permit Fee , $0.00J / AddIRecI. Water Con. Fee". $0.00
Plan Check /$653.56 Meter Fee' $140.00
Addl Plan Check Fee' $0.00 " . SDCWA Fee . , $2,004.00
Plan Check Discount ' " $0.00 CFD Payoff Fee . $0.00
Strong Motion Fee N $24.83 PFF ' '••/ \ , $4,518.66
Park in Lieu Fee \\$0.00 PFF (CFD Fund) ,-' $4,171.07
Park Fee $0.00 License Tax / $0.00
LFM Fee $0.09 License Tax (CFD Fund) ',/ $0.00
Bridge Fee $0.00'°. 'Traffic Impact Fee -: ", $701.24
Other Bridge Fee $0.00 'Traffic Impact (CFD'Fund)
,
$790.76
BTD #2 Fee ' . $0.00 Sidewalk Fee' 'C '- ' $0.00
BTD #3 Fee $0.00 PLUMBING TOTAL \ I $238.00
Renewal Fee N $0.00 --l'ELECTRICAL TOTAL i/ . $110.00
AddI Renewal Fee N $0.00'" MECHANICAL TOTAL / $63.50
Other Building Fee '. \ $60.00 . Housing Impact Fee / $0.00
Pot. Water Con. Fee $2,400.00 Housing InLieu Fee / $0.00
Meter Size "D5/8 r 0r Ma5terDrage Fee' $0.00
AddI Pot. Water Con. Fee ' '/ N. $0.00 Sewer Fed •' $4,038.00
Red. Water Con. Fee \ , $0.00 Additional Fees / / $0.00
TOTAL PERMIT FEES •.•• ' $20,919.10
FINAL APPROVAL
4g
lnsDector: Date: ____________ Clearance:
NOTICE: Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as lees/exactions." You have 90days from the date this permit was issued to protest imposition of these fees/exactions. if you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition. -
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
Name
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ONLY
PLAN CHECK NO.O/ z2y-
EST. VAL. 9k?,
Plan Ck. Deposit 53,5
Validated By / -1eJr
Date
Li PT RM ON,
Business Name (at this addréssT —_JCGP 653.56
Legal Descttion L No. Subdivsion Name/Number Unit No. Phase No. Total # of units
7 3'
AINT r flAgen,fpntractor
'
.
9 r7(o( Name - Address City 7't-ate o p T lephon C
- - -' -
- - ,_ - Name Address City S 1t/,p Telephone C
, -
(Sec. 7031.5 Business and Professions code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged
exempt,p1- 4olation of Section ,,31.5 by a.applicat.or a (mit stjets the appa)t to a civil penalty of not m,9i'ejn five !Jjindre...ollars [$5001(.
Name - Address ' City Stafe/Zip lIeph'ne#
State License # __________-, License Class
-_( City Business License
rc 1Z-'--
ues,gner Name Address City. State/Zip Telephone
State License #
kESçOMPENSATION I Workers' Compensation Declaration: l hereby affirm under penalty of perjury one of the following declarations:
O I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
lii.,e and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
Insurance Company
I bar are:
Policy No. Expiration Date__________________
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS F ONE HUNDRED DOLLARS [$1001 OR LESS)
o CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand doIlas ($100,000), in addition to the cost of compensation, damages asprovided for in Section 3706 of the Labor code, interest and attorney's fees.
SIGNATURE DATE
PWNTh___iLL DECLARW' :
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
-
- C3 I, as owner of the property or my employees with wages-as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold in one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon; and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law). -
0 I-am exempt under Section Business and Professions Code for this reason:
-
-
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES
2.
Pve
have not) signed an application for a building permit for the proposed work.
3.. contracted with the following person (firm) to provide the proposed construction (include name / address I phone number / Contractors license number):
4. I plan to provide portions of the work, but ,l have hired the folloyiing,pers to coordiq super and providQt$ major e' (inclu e name I address / phone number / contractors license number): _/,'/J_-'_"—')_j')?A_i"_2'7 IL
I will provide some of the work, but I have contracted lhired,e4olloy)ng persons to provide the work indicated (include name / address / phone number / type
of work): _11 I'! II - .1 1 1
PROPERTY OWNER SIGNATURE i/fl'e DATE cI77 Z c ( (
Is the applicant or future building-occupant required to submit a business plan, acutely hazardous materials registration risk management and prevention form
program under Sections 25505. 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES - NO.
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO
IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CQ[RU CJ,ION LENDING
hereby affirm that there is y
1construction lending agency for the performance of the work for which this permit is issued (Sec. 309701 civil Code).
LENDER'S NAME - - LENDER'S ADDRESS - ,.- -
19 AER ?JIJPJ TL.
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST' ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA:, An OSHA permit is required for excavations over 50" deep and demolition or construction of structures over 3 stories in height. -
-EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 ay om the date of such permit or if the building or work authorized by such permit is su ended or abandoned
at any time after the work is com, c d I PerioUniform Building Code).
APPLICANT'S SIGNATURE DATE ____________________________ IV - - - - tl WHITE File YELLOW Applicant PINK Finance
City of Carlsbad Bldg Inspection Request
For: 08/26/2002
Permit# CB012754
Title: OGARA RES-2315 SF, 480 SF GAR
Description: 438 SF 2ND DWELLING UNIT
Type: RESDNTL Sub Type: SFD
Job Address: 1060 MAGNOLIA AV
Suite: Lot 0
Location:
APPLICANT OGARA MICHAEL D&VICKI B
Owner: OGARA MICHAEL D&VICKI B
Remarks:
Inspector Assignment: RF
Phone: 7605191004
Inspector: /j ,c'
Total Time: Requested By: MIKE 0 GARA
Entered By: KAREN
CD Description Act Comments
19 Final Structural
29 Final Plumbing /9
39 Final Electrical /9/' E/-/ '/ G-g (/oo '-4) (oô
49 Final Mechanical
Associated PCRs/CVs
Inspection History
Date Description Act Insp comments
08/23/2002 89 Final Combo CA RF NOT READY, RESCHEDULE FOR MONDAY.
08/12/2002 19 Final Structural CO RF FIRE WALL PENITRATION
08/12/2002 29 Final Plumbing CO RF SINGLE WALL VENT (WATER HEATER) 61N CLEAR.
08/12/2002 39 Final Electrical CO RF LIGHT FIXTURES NOT INSTALLED
08/12/2002 49 Final Mechanical CO RF HEAD CLEARANCE ATTIC ACCESS
08/09/2002 89 Final Combo CO RF KITCHEN COUNTER WIRED TO WALL RECEPT.
08/07/2002 19 Final Structural NR RF
08/07/2002 29 Final Plumbing NR RF DO NOT RELEASE GAS TILL FINAL
08/07/2002 39 Final Electrical NR RF CAN NOT CONNECT KIT ISLAND TO WALL RECEPT.
08/07/2002 49 Final Mechanical NR RF
08/06/2002 89 Final Combo CO RF ELECTRICAL -NMC HANGING OUT OF WALL ETC
08/02/2002 23 Gas/Test/Repairs AP RF HOUSE
08/01/2002 23 Gas/Test/Repairs CO RF GAS TEST BOTH HOUSE & GRANNY FLAT? 2 METERS?
07/30/2002 89 Final Combo NR RF
07/22/2002 39 Final Electrical NR RF NO ONE HOME. ELECT. NOT READY
04/25/2002 17 Interior Lath/Drywall AP RC
1~0 t t %N City of Carlsbad Bldg Inspection Request
For: 08/26/2002
Permit# CB012754
04/25/2002 18 Exterior Lath/Drywall AP RC
04/25/2002 23 Gas/Test/Repairs PA RC
04/24/2002 17 Interior Lath/Drywall CO RC
04/19/2002 16 Insulation AP RC
04/19/2002 24 Rough/Topout AP RC
04/18/2002 14 Frame/Steel/Bolting/Welding CA RC
04/18/2002 24 Rough/Topout CA RC
04/12/2002 14 Frame/Steel/Bolting/Welding AP RC
04/12/2002 24 Rough/Topout PA RC
04/12/2002 34 Rough Electric AP RC
04/12/2002 44 Rough/Ducts/Dampers AP RC
04/11/2002 14 Frame/Steel/Bolting/Welding CO RC
04/11/2002 24 Rough/Topout NR RC
04/11/2002 34 Rough Electric AP RC
04/11/2002 44 Rough/Ducts/Dampers AP RC
03/29/2002 84 Rough Combo NR RC
03/27/2002 84 Rough Combo NR RC
03/25/2002 84 Rough Combo CA PD
03/11/2002 14 Frame/Steel/Bolting/Welding PA RC
01/31/2002 13 Shear Panels/HD's PA RC
01/29/2002 13 Shear Panels/HD's CO RC
01/22/2002 13 Shear Panels/HD's CO RC
01/17/2002 13 Shear Panels/HD's CO NF
01/11/2002 13 Shear Panels/HD's CA RC
01/11/2002 14 Frame/Steel/Bolting/Welding WC RC
01/11/2002 15 Roof/Reroof AP RC
11/19/2001 32 Const. Service/Agricultural AP RC
10/30/2001 11 Ftg/Foundation/Piers AP RC
10/26/2001 11 Ftg/Foundation/Piers NR PD
10/16/2001 21 Underground/Under Floor AP RC
Inspector Assignment: RF
GRANNY FLAT - OK - HOUSE HAS BROKEN GAUGE
HOUSE NOT SCRAPPED OUT
OK TO DRYWALL
BY MIKE
OK TO INSULATE - DO NOT DRYWALL
NOT FULL TO TOP
SPEC. INSP. REPORT FILED FOR FIX ON 3 X BOTTOM PLATE
A-355, RATPROOFING, LIST W/SUPER
SYSTEM 1/2 EMPTY
SEE NOTICE - RE-INSP FEE DUE
SUPER DID NOT WALK HOUSE - TOO MANY CORRECTIONS
OK TO INSTALL SHEAR IN GARAGE WALL
EXT. ONLY - OK TO WRAP
SEE NOTICE (MISSING HARDWARE)
MISSING TECO S & MST STRAPS
NO SUPERVISION
OK TO COVER
TSPB RELEASED
OK TO POUR
HARDWARE, STEEL NOT IN-SEE ATTACHED NOTICE
OK TO COVER
ldf rA-
Inspection Date: —',?
Carl Schmidt Inspection ~~b
RO. Box 178403
San Diego. CA 92177-8403
Phone (619) 855-9252
SPECIAL INSPECTION REPORT
PROJECT: _J T '' (p / GSM) JOB START: ;2,A9
ADDRESS:/hO Af46f4/4/,4 4I/4 JOB STOP:
CITY:, PERMIT #: C B i73/ 27f4 PLAN FILE #:
TYPE OF OBSERVATIONS: MASONRY_ REINFORCED CONCRETE_ FIELD WELDING_ EPDXY-'
PRESTRESSED CONCRETE_ SHOP WELDING_ BOLTING_ REINFORCING STEEL_ FIREPROOFING_
SAMPLES: NUMBER: 1VPE:
MateaIs/Design Mix Numbers/PSI:
WORK INSPECTED CONFORMS WITH APPROVED PLANS AND SPECIFICATIONS UNLESS OTHERWISE NOTED
CL1yt6'A/ h4'&t7zJEi sp /ç
Print Name Certificafion# ,
Eliplill Inspef&rs Signatu,.2
li"ll I ONE
,
ON 1 0 01
11w i
Phone: (
Fax:( )_
57/
FROM : NRtERS DESIGN CONSULTING 'PHONE NO. : 619 204 0037
73L'12 14/a /_' /e5 C
Apr. 05 2002 0512PM P1
2 'AILA
r— Ay\ f J
L
ak ) C
C)
/c,,o /'11Th1voi.14
/*
31K ri.
/!I/OZ flC
-
City 01 Carlsbad
Final Building Inspection
Dept: Building Engineering Plg MWD St Lite Fire
Plan Check #: Date: 07/30/2002
Permit #: CB012754 Permit Type: RESDNTL
Project Name: O'GARA RES-2315 SF, 480 SF GAR Sub Type: SFD
438 SF 2ND DWELLING UNIT
Address: 1060 MAGNOLIA AV Lot: 0
Contact Person: MICHAEL Phone: 7605191004
Sewer Dist: CA Water Dist: CA
Inspected Date
'• By: W7 Inspected: ( 01..—Approved: Disapproved:
Inspected Date
By: Inspected: Approved: Disapproved:
Inspected Date
By: Inspected: -Approved: Disapproved:
Comments:
CIty 01 Carlsbad
Final Building Inspection
Dept: Building Engineering Planning CMWD St Lite Fire
Plan Check #: Date: 07/30/2002
Permit #: CB012754 Permitlype: RESDNTL
Project Name: OGARA RES-2315 SF, 480 SF GAR Sub Type: SFD
438 SF 2ND DWELLING UNIT
Address: 1060 MAGNOLIA AV Lot: 0
Contact Person: MICHAEL Phone: 7605191004
Sewer Dist: CA Water Dist: CA
Inspected Date
By: Inspected: Approved: Disapproved:
Inspected Date
By: - Inspected: Approved: L_6iapproved: ____
Inspected Date
By: Inspected: Approved: Disapproved:
Comments:
Orj ,'j---z'?I 5 f) +0 /i-'.
EsGil Corporation
In Partnership with government for uifiuing Safety
DATE: October 3, 2001
JURISDICTION: Carlsbad
PLAN CHECK NO.: 01-2754 SET: II
PROJECT ADDRESS: 1060 Magnolia Ave.
PROJECT NAME: SFD for Mike Ogara
ULICANT
D PLAN REVIEWER
U FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation: until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
LII The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted:. (by: ) Fax #:
Mail Telephone Fax In Person
REMARKS: A - Structural plans shall be sealed and signed by the engineer. B - Party wall
shall be provided between the Garage and the Second Dwelling.
By: Sergio Azuela Enclosures:
Esgil Corporation
El GA ] MB [J EJ [1 PC 9/25 trnsmtl.dot
EsGil Corporation
1n Partnership with Government for Bui(1ing Safety
DATE: August 31, 2001
JURISDICTION: Carlsbad
PLAN CHECK NO.: 01-2754
PROJECT ADDRESS: 1060 Magnolia Ave.
PROJECT NAME: SFD for Mike O'gara
SET:I
U CANT
JURIS
U PLAN REVIEWER
U FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The. check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
LII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Mike O'gara
P.O. Box 1633, Carlsbad, CA 92018
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Mike O'gara Telephone #: (760) 519-1004
Date contacted: -4--1 (by: - ) Fax #: (760) 434-7563
Mail - Telephone .- Fax .-' In Person
REMARKS:
By: Sergio Azuela Enclosures:
Esgil Corporation
L:IGA DMB EEJ LPC 8/23 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576
Carlsbad 01-2754
August 31, 2001
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 01-2754 JURISDICTION: Carlsbad
PROJECT ADDRESS: 1060 Magnolia Ave.
FLOOR AREA: Dwelling 2,315 SF STORIES: 2
Garage 480 SF, Porch 144 SF
Second Dwelling 438 SF, Porch 26 SF HEIGHT: 22 FT
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 8/21/01
DATE INITIAL PLAN REVIEW
COMPLETED: August 31, 2001
FOREWORD (PLEASE. READ):
'DATE PLANS RECEIVED BY
ESGIL CORPORATION: 8/23
PLAN REVIEWER: Sergio Azuela
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments. Clearance from those departments may be required prior to
the issuance of a building permit.
Present California law mandates that residential construction comply with the 1998 edition of
the California Building Code (Title 24), which adopts the following model codes: 1997 UBC,
1997 UPC, 1997 UMC and 1996 NEC (all effective 7/1/99).
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad 01-2754
August 31, 2001
. PLANS
1. Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. Plans, specifications and calculations shall be signed and sealed by the
California state licensed engineer or architect responsible for their preparation,
for plans deviating from conventional wood frame construction. Specify
expiration date of license. (California Business and Professions Code).
a) Structural plans shall be sealed and signed by the licensed engineer in
the State of California, responsible for the preparation of the structural
design calculations.
3. Specify on the Title Sheet of the plans the gross floor area of each element of
this project, including, porch. Section 106.3.3.
4. Provide a statement on the Title Sheet of the plans stating that this project shall
comply with the 1998 edition of the California Building Code (Title 24), which
adopts the 1997 UBC, UMC and UPC and the 1996 NEC.
. GENERAL RESIDENTIAL REQUIREMENTS
5. Sleeping rooms shall have a window or exterior door for emergency escape. Sill
height shall not exceed 44" above the floor. Windows must have an openable
area of at least 5.7 square feet with the minimum openable width 20" and the
minimum openable height 24". The emergency door.or window shall be
openable from the inside to provide a full, clear opening without the use of
separate tools. Section 3104.
a) Window U is shown to be an "EGRESS" window, however, in the window
schedule is marked as "FIXED". Please clarify.
Carlsbad 01-2754
August 31, 2001
Openable window area in habitable rooms must be 1/20 of the floor area and a
minimum of 5 square feet. In bathrooms and water closet compartments, 1/20 of
area is required and minimum is 1.5 sq. ft. Section 1203.3.
a) Window U is shown to be an "EGRESS" window, however, in the window
schedule is marked as "FIXED". Please clarify.
Provide mechanical ventilation capable of providing five air changes per hour in
bathrooms and water closet compartments if required openable windows are not
provided. Section 1203.3.
Note that the discharge point for exhaust air will be at least 3 feet from any
opening. which allows air entry into occupied portions of the building. Section
1203.3.
EXITS, STAIRWAYS, AND RAILINGS
9. Provide stairway and landing details. Sections 1003.3.3.
Minimum headroom is 6'-8".
Minimum width is 36".
Clearly show the applicable dimensions on plans.
10. Handrails (Section 1003.3.3.6):
a) Handrails and extensions shall be 34" to 38" above nosing of treads and
be continuous.
i) Clearly show it on plans above nosing of treads on detail 12/S3.
ROOFING
11. Specify roof material and application. Chapter 15.
12. Specify on the plans the following information for the roof materials, per Section
106.3.3:
Manufacturer's name.
Product name/number.
ICBO approval number, or equal.
13. Per local ordinance, a Class "A" roof is required.
14. Show the required ventilation for attics (or enclosed rafter spaces formed where
ceilings are applied directly to the underside of roof rafters). The minimum vent
area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required
vent is at least 3 feet above eave vents or cornice vents). Show area required
and area provided. Section 1505.3.
Carlsbad 01-2754
August 31, 2001
Where eave vents are installed, insulation shall not block the free flow of air. A
minimum of 1" of air space shall be provided between the insulation and the roof
sheathing. To accommodate the thickness of insulation plus the required 1"
clearance, member sizes may have to be increased for rafter-ceiling joists.
Section 1505.3.
Note on the plans: "Attic ventilation openings shall be covered with
corrosion-resistant metal mesh with mesh openings of 1/4-inch in dimension.
Section 1505.3.
. FOUNDATION REQUIREMENTS
Provide a copy of the project soil report prepared by a California licensed
architect or civil engineer. The report shall include foundation design
recommendations based on the engineer's findings and shall comply with UBC
Section 1804.
a) At the City of Carlsbad all new residential buildings require a soils report.
Show distance from foundation to edge of cut or fill slopes ("distance-to-
daylight") and show slope and heights of cuts and fills. Chapter 18.
Note on plans that surface water will drain away from building and show drainage
pattern. Section 1804.7.
Show foundation bolt size and spacing. Foundation bolt size and spacing for
shear walls must be clearly shown on the foundation plan. Section 1806.6.
a) Clearly show on plans which option will be followed in each shear wall
from SCHEAR TRANSFER SCHEDULE options from A to H.
FRAMING
Provide truss details and truss calculations for this project. Specify truss
identification numbers on the plans.
Please show in the calculations how the redundancy was determined, per
Section 1630.1.1.
. MECHANICAL (UNIFORM MECHANICAL CODE)
Show the type and size (BTU's) of all heating and cooling appliances or systems.
. ELECTRICAL (NATIONAL ELECTRICAL CODE)
Show on the plan the amperage of the electrical service, the location of the
service panel and the location of any sub-panels. If service is over 200 amps,
submit single line diagram, panel schedule and load calculations.
Carlsbad 01-2754
August 31, 2001
Note on the plans that receptacle outlet locations will comply with NEC Art.
210-52(a).
. PLUMBING '(UNIFORM PLUMBING CODE)
In the garage, provide an adequate barrier to protect water heater from vehicle
damage. An 18" platform for the water heater does not satisfy this requirement.
UPC, Section 510.3.
Show T and P valve on water heater and show route of discharge line-to exterior.
UPC, Section 608.5.
. NOISE INSULATION (DUPLEXES)
Show details of duplex common (party) walls and floor/ceiling assemblies to
achieve a Sound Transmission Class (STC) rating in walls of 50 decibels and an
Impact Insulation Class (llC) rating on floor/ceiling of 50 decibels. Title 24.
Show how penetrations of assemblies for piping, electrical devices, recessed
cabinets, bathtubs, soffits, or heating ventilating, or exhaust ducts shall be
sealed, lined, or insulated to maintain required sound transmission rating. Title
24.
Provide insulation in walls and ceiling to achieve STC of 50 between garage and
living area if garage use is not controlled by resident. Title 24.
. ENERGY CONSERVATION
The window schedule shall clearly describe the required U-factor and solar heat
gain coefficient (SHGC) values and demonstrate compliance with the Title 24
energy calculations.
The regulations require a properly completed and properly signed Form CF-1 R to
be either imprinted on the plans, taped to the plans or "sticky backed" on the
plans, to allow the building inspector to readily compare the actual construction
with the requirements of the approved energy design.
All sheets of the latest CF-1 R form must be imprinted onto the plans (sheets 1 of
3, 2 of 3 and 3 of 3 must be included).
Specify on the building plans all of the mandatory energy conservation
requirements as listed on the enclosure titled, "Mandatory Measures Checklist".
Show the make, model, type and efficiency of the space heating (or cooling)
system.
Carlsbad 01-2754
August 31, 2001
Note on the plans: "The manufactured windows shall have a label attached
certified by the National Fenestration Rating Council (NFRC) and showing
compliance with the energy calculations."
. MISCELLANEOUS
Clearly show on plans compliance with Section 1633.2.9. By providing drag/strut
members and connections at all re-entrant corners.
CARLSBAD SPECIAL CODE REQUIREMENTS
New residential units must be pre-plumbed for future solar water heating. Note
"two roof jacks must be installed" where the water heater is in the one story garage
and directly below the most south facing roof (City Ordinance No. 8093).
Note "two 3/4" copper pipes must be installed to the most convenient future solar
panel location when the water heater is not in a one story garage and is not directly
below the most south facing roof. (City Ordinance No. 8093).
All piping for present or future solar water heating must be insulated when in areas
that are not heated or cooled by mechanical means (City Policy).
To speed up the review process, note on this list (or a copy) where each correction item
has been addressed, i.e., plan sheet, note or detail number, calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a result
of corrections from this list: If there are other changes, please briefly describe them
and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list? Please
indicate:
Yes El No U
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding these plan
review items, please contact Sergio Azuela at Esgil Corporation. Thank you.
Carlsbad 01-2754
August 31, 2001
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 01-2754
PREPARED BY: Sergio Azuela DATE: August 31, 2001
BUILDING ADDRESS: 1060 Magnolia Ave. SFD for Mike Ogara
BUILDING OCCUPANCY: R-3 & U-i TYPE OF CONSTRUCTION: V-N
BUILDING
PORTION
AREA
(Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
Dwelling 2753 248,278
Garage 480
Air Conditioning
Fire Sprinklers
TOTAL VALUE 248,278
Jurisdiction Code 1cb IBY Ordinance
1994 UBC Building Permit Fee I $1 ,005.481
1994 UBC Plan Check Fee I $653.56 I
Type of Review: E1 Complete Review Lj Structural Only
LI Other M Repetitive Fee
Repeats LI Hourly Hour *
I Esgil Plan Review Fee I $563.07
Comments:
Sheet I of 1
macvaluedoc
of Carlsbad
9/14(0 ! BUILDING PLANCHECK CHECKLIST
DATE: PLANCHECK NO.: CB C O (
BUILDING ADDRESS: U A/4i (Si/1)tC
PROJECT DESCRIPTION:
ASSESSOR'S PARCEL NUMBER: /c9/. L-/— EST. VALUE:
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build.
IA Right-of-Way permit is required prior to
construction of the following improvements:
DENIAL
Please see the attached report of deficiencies
marked with 0. Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards. Submit corrected plans and/or
specifications to this office for review.
By: Date:
By: - Date:
By: Date:
FOR OFFICIAL USE ONLY
ERING UTHORIZATION TO ISSUE BUILDING PE
Date/24f"/
ENGINEERING DEPT. CONTACT PERSON
Name: KATHLEEN M. FARMER
City of Carlsbad
Address: 1635 Faraday Avenue, Carlsbad, CA 92008
Phone: (760) 602-2741
By:
ATTACHMENTS
LI Dedication Application
LI Dedication Checklist
LI Improvement Application
LI Improvement Checklist
LI Future Improvement Agreement CFD INFORMATION
LI Grading Permit Application Parcel Map No:
LI Grading Submittal Checklist Lots:
LI Right-of-Way Permit Application Recordation:
LI Right-of-Way Permit Submittal Checklist Carlsbad Tract: and Information Sheet
LI Sewer Fee Information Sheet A-4
H:kWORDIpf;8;5KP%V&Tpap!~eAG$qSFM".edc)4&a r Is bad, CA 9200-7314. (760) 602-2720 • FAX (760) 60280
BUILDING PLANCHECK CHECKLIST
SITE PLAN
1ST 3RD
.1. Provide a fully dimensioned site plan drawn to scale. Show:
Arrow ght-of-Way Width & Adjacent Streets
,fr-txisting & Proposed Structures G.Qriveway widths
CExisting Street Improvements ,-H Existing or proposed sewer lateral
roperty Lines )-isting or proposed water service
Easements )_-Eiting or proposed irrigation service
D 0 2. Show on site plan:
A. Drainage Patterns
Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course.
ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building."
B. Existing & Proposed Slopes and Topography
C. Size, type, location, alignment of existing or proposed sewer and water service
(s) that serves the project. Each unit requires a separate service, however,
second dwelling units and apartment complexes are an exception.
D. Sewer and water laterals should not be located within proposed driveways, per
standards.
3. Include on title sheet:
Site address
Assessor's Parcel Number
Legal Description
For commercial/industrial buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc.) previously approved.
EXISTING PERMIT NUMBER I DESCRIPTION
H:\W0RO\D0CS\CHKLS1'8uild Planthedc Cktst Form (Generlc).dOC 2 Rev. 7/14(00
1
C6
7
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3rd DISCRETIONARY APPROVAL COMPLIANCE
E 4a. Project does not comply with the following Engineering Conditions of approval for
ProjectNo.________________________________________________________
E 4b. All conditions are in compliance. Date:
DEDICATION REQUIREMENTS
5. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
- for remodels with a value at or exceeding $15,000, pursuant to Carlsbad
Municipal Code Section 18.40.030.
":5
Dedication required as follows:
Dedication required. Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 1/2" x 11" plat map
and submit with a title report. All easement documents must be approved and
signed by owner(s) prior to issuance of Building Permit. Attached please find an
application form and submittal checklist for the dedication process. Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person. Applications will not be accept by mail or fax.
Dedication completed by: Date:
IMPROVEMENT REQUIREMENTS
6a. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $75,000, pursuant to Carlsbad Municipal Code Section
18.40.040.
Public improvements required as follows:
Attached please find an application form and submittal checklist for the public
improvement requirements. A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process. The completed application form and the requirements on the
H:WORD\DOCS\CHKLST\BujIdjng Plancheek Cidat Form (RIDDLE HARVEY 7-12-00).doc 3 Rev. 12126/98
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3rd
checklist must be submitted in person. Applications by mail or fax are not
accepted. Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit.
Improvement Plans signed by: Date:
LI LI LI 6b. Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or
current grant deed on the property and processing fee of $280 so we may
prepare the necessary Neighborhood Improvement Agreement. This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit.
Neighborhood Improvement Agreement will include the following:
LI LI LI 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return
agreement signed and notarized to the Engineering Department.
Neighborhood Improvement Agreement completed by:
Date:
LI LI LI 6d. No Public Improvements required SPECIAL NOTE: Damaged or defective
improvements found adiacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11.06.030 of the Municipal Code.
LI LI LI 7a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
45 LI LI 7b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form I" attached. NOTE: The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit.
Grading Inspector sign off by: Date:
(#LI LI 7c. Graded Pad Certification required. (Note: Pad certification may be required even
if a grading permit is not required.)
H:\WORD\DOCSCHK1ST8ufldirig PIncfleck Ckt Form (RIDDLE - HARVEY 71200).doc 4 Rev. 9/28/00
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3RD
0 0 0 7d .No Grading Permit required.
0 0 0 7e. If grading is not required, write "No Grading" on plot plan.
MISCELLANEOUS PERMITS
0 0 0 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are
not limited to: street improvements, tree trimming, driveway construction, tying
into public storm drain, sewer and water utilities.
Right-Of-Way permit required for:
0 0 0 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153,
for assistance.
Industrial Waste permit accepted by:
Date:
0 0 0 10. NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit. The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas. Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs
Ir
t.
,,[Z"11. ''Requiredfeesare attached
II No fees required
WATER METER REVIEW
0 0 0 12a. Domestic (potable) Use
Ensure that the meter proposed by the owner/developer is not oversized.
Oversized meters are inaccurate during low-flow conditions. If it is oversized, for
the life of the meter, the City will not accurately bill the owner for the water used.
All single family dwelling units received "standard" 1" service with 5/8" service.
H:\W0R0D0CSCHKLSfl3u1dfrg Planthedc Cidsi Form (Generlc).doc 5 Rev. 7114100
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3RD
If owner/developer proposes a size other than the "standard", then
owner/developer must provide potable water demand calculations,
which include total fixture counts and maximum water demand in gallons
per minute (gpm). A typical fixture count and water demand worksheet is
attached. Once the gpm is provided, check against the "meter sizing
schedule" to verify the anticipated meter size for the unit.
Maximum service and meter size is a 2" service with a 2" meter.
If a developer is proposing a meter greater than 2", suggest the
installation of multiple 2" services as needed to provide the anticipated
demand. (manifolds are considered on case by case basis to limit
multiple trenching into the street).
E 12b. Irrigation Use (where recycled water is not available)
All irrigation meters must be sized via irrigation calculations (in gpm) prior
to approval. The developer must provide these calculations. Please follow
these guidelines:
If the project is a newer development (newer than 1998), check the recent
improvement plans and observe if the new irrigation service is reflected on
the improvement sheets. If so, at the water meter station, the demand in
gpm may be listed there. Irrigation services are listed with a circled "I",
and potable water is typically a circled "W". The irrigation service should
look like:
....J ,-. STA 1+00 Install 2" service and
1.5: meter (estimated 100 gpm)
If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case
irrigation demand (largest zone with the farthest reach). Typically, Larry
Black has already reviewed this if landscape plans have been prepared,
but the applicant must provide the calculations to you for your use. Once
you have received a good example of irrigation calculations, keep a set for
your reference. In general the calculations will include:
Hydraulic grade line
Elevation at point of connection (P00)
Pressure at P00 in pounds per square inch (PSI)
Worse case zone (largest, farthest away from valve
Total Sprinkler heads listed (with gpm use per head)
Include a 10% residual pressure at point of connection
3. In general, all major sloped areas of a subdivision/project are to be
irrigated via separate irrigation meters (unless the project is only SFD with
no HOA). As long as the project is located within the City recycled water
H:WORD\DOCS\CHKLST\BuikJng PLIncheck Cldst Form (Geneflc).doc 6 Rev. 7114100
BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD
service boundary, the City intends on switching these irrigation
services/meters to a new recycled water line in the future.
E 12c. irrigation Use (where recycled water is available)
Recycled water meters are sized the same as the irrigation meter above.
If a project fronts a street with recycled water, then they should be
connecting to this line to irrigate slopes within the development. For
subdivisions, this should have been identified, and implemented on the
improvement plans. Installing recycled water meters is a benefit for the
applicant since they are exempt from paying the San Diego County Water
Capacity fees. However, if they front a street which the recycled water is
there, but is not live (sometimes they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego
Water Capacity Charge. If within three years, the recycled water line is
charged with recycled water by CMWD, then the applicant can apply for a
refund to the San Diego County Water Authority (SDCWA) for a refund.
However, let the applicant know that we cannot guarantee the refund, and
they must deal with the SDCWA for this.
D 0 LI 13. Additional Comments:
H:\WORDDOCS\CHKLSflBuIng Planchedc Cklst Form (Generc).do
- 7 Re,. 7114/00
P
ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
Estimate based on unconfirmed information from applicant.
O Calculation based on/uilding plancheck plan submittal.
0 Bldg. Permit No. Address: (
O D 0! 1
Prepared by: I*UJ_'1 ) DaPe: Checked by:. Date:
EDUCALCULATIONS: List types and square footages for all uses.
Types of Use: $_(1)-F-S_U. Sq. EDUs: 21—
Types- of Use: Sq. Ft./Units: EDU's:
ADTCALCULATIONS: List types and square footages for all uses.
Types of Use: J('OfSO1' Sq. Ft./Units: /_— ADT's:
Types of Use: . Sq. Ft./Units: ADT's:
FEESREQUIRED:
WITHIN CFD: 0 YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) 0 NO
0 1. PARK-IN-LIEU FEE . PARK AREA & #:
FEE/UNIT: X NO. UNITS:______
0 2. TRAFFIC IMPACT FEE .
ADT's/UNITS( -1-c X /ADT: 4?- L(
3. BRIDGE. AND THOROUHFE FEE (01ST. #1 01ST. #2 01ST. #3
ADT's/UNITS: X FEE/ADT: =$—
4. FACILITIES MANAGEMENT FEE ZONE:_________
UNIT/SQ.FT.: X FEEISQ.FT./UNIT:_________
5.
SEWERE:.s:lIIIIII ::::;;;?
BENEFIT AREA: —
EDU's:
6. SEWER LATERAL ($2,500)
0 7. DRAINAGE FEES PLDA : HIGH /LOW
ACRES: X FEE/AC:__________
0 8. POTABLE WATER FEES
UN S CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION
-
lof2
WordDocs\MisformsFee Calculation Worksheet . Rev. 7/14/00
X FEE/EDLI '2
X FEE/EDU:________
I
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CBOL 7.5'1 Address OCO 'i''' Uct
Planner Paul Godwin Phone 760-602-4625
APN: p05 -qI-g1-00
a'S Type of Project & Use: SFP ISP Net Project Density: DU/AC
Zoning: General Plan: - Facilities Management Zone:__________
CFD (in/out) # Date of participation: Remaining net dev acres:
Circle One
(For non-residential development: Type of land used created by this
permit: )
Legend: Z Item Complete Item Incomplete - Needs your action
Environmental Review Required: YES NOX TYPE
DATE OF COMPLETION: -
Compliance with conditions of approval? If not, state cdnditions which require action.
Conditions of Approval:
Discretionary Action Required: YES NO TYPE
APPROVAL/RESO. NO. DATE
PROJECT NO. St3IAOi33
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES____ NO 1\
CA Coastal Commission Authority? YES NO____
If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Dr, Suite 103, San Diego
CA92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Coastal Permit Determination Form already completed?
If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log #:
Follow-Up Actions:
YES NO
Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor
Plans).
Complete Coastal Permit Determination Log as needed.
H:\ADMIN\COUNTER\BldgPlnchkRevChklst
Inclusionary Housing Fee required: YES NO
( ' (Effective date of Inclusionary Housing Ordinance - May 21, 1993.)
Data Entry Completed? YES NO
A,
-
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing YIN, Enter Fee, UPDATE!)
Site Plan:
Provide a fully dimensional site plan drawn to scale. Show: North arrow, property
lines; easements, existing and proposed structures, streets, existing street
improvements, right-of-way width, dimensional setbacks and existing topographical
lines.
Provide legal description of property and assessor's parcel number.
Zoning:
1. Setbacks: /
Front: Required Shown c O
Interior Side: Required ci 1 Shown 31"
Street Side: Required ' '+' Shown
Rear: Required 1 " Shown
2. Accessory structure setbacks:
ro . Required Shown
Interior Side: e Shown_______________
Street Side: Required Shown
Additional Comments ..
OK TO ISSUE AND APPROVAL ENTERED INTO COMPUTER itL24&41i DATE
H:\ADMIN\COUNTER\BldgPlnchkRevChklst
Rear: Required Show
Structure separation: Required Shown
Lot Coverage: Required 0 Shown 90
Height: Required '3c "
Shown
Parking: Spaces Required Shown
Guest Spaces Required Shown
SUMMIT DESIGN ENGINEERING
STRUCTURAL AND CIVIL
7224 Margerum Ave. 4422 Glacier Ave. #F San Diego, CA 92120 San Diego, CA 92120 Phone (619) 582-2721 Phone (619) 284-1848
Fax 284-0837
Structural Calculation
For Proposed
S.F.R.
Addition
To be located at:
Magnolia Ave. Lot #3
Carlsbad, CA
Designer:
Samuel B. Wright
2911 State St.
Carlsbad, CA 92008
Owner:
O'gara
Project:
MJ 495-01
OESS1ON4
MAH
LU t311: ))'
Date:
7/30/01
64O' 2 7c'j
c3. Specializing
floor
in roof
trusses
a nd
0
It
COMMERCIAL • RESIDENTIAL'
'ROOM ADDITIONS'
'COMPETITIVE PRICES
FREE AND PROMPT ESTIMATES*
k\O 00itz4hul', 4f0.
2847 INDUSTRY STREET
OCEANSIDE, CA. 92054
ICBO#AA-513
(76o) 722-7696
FAX (7o) 722 - 0438
G&I2,71q
'"qq
SOIL irIBSTIBES
June 9, 1999
P.O. Box 1195
Lakeside, California 92040
(619) 443-0060
(619)443-0933 Fax
Mike O'Gara
P.O. Box 1633
Carlsbad, California 92018
SUBJECT: File No. 9796
SITE INSPECTION
Proposed Residential Building Site
Magnolia Avenue
City of Carlsbad
Tract 9723, Phase I
Dear Mr. O'Gara:
SCOPE
In accordance with your request, a Site Inspection has been performed at the subject site. The
purpose of this investigation was to examine existing site conditions and provide engineering
recommendations for the proposed 4 single-family residences.
FIELD INSPECTION
In order to accomplish this purpose, a representative of this firm visited the site, reviewed the
topography and site conditions and visually and textually classified the surface and near surface
soils. Representative samples of the on-site soils were obtained from a test exploration 3 feet in
depth and tested for density, shear strength and expansive characteristics. Similar soils and
conditions were observed in two other explorations.
SITE CONDITIONS
The subject site is an undeveloped parcel located on the northerly side of Magnolia Avenue. The
site is relatively level with an approximate one percent fall to the southeast. No man made fill
soils were observed during the course of this inspection.
SOIL CONDITIONS
Soils encountered in the test explorations were dark brown, silty, fine sands to medium sands to
1
C6 61Z7 fq
Mike O'Gara File No. 9796 June 9, 1999
approximately 2 feet in depth. These surface soils were loose and compressible. Underlying the
loose surface soils were medium dense, red brown, fine to medium sands. None of soils we
encountered were considered to be detrimentally expansive with respect to change in volume
with change in moisture content (Expansion Index 15).
An in-place field density test taken in accordance with A.S.TM D1556.-82 at the bottom of the
exploration (approximately 3 feet in depth) indicated relative compaction of the soils at that level
to be 92.9 percent.
CONCLUSIONS AND RECOMMENDATIONS
The loose native soils we encountered should not be utilized to support the proposed
new structure. They should be recompacted to at least 90 percent of maximum dry
density in accordance with the Grading Specifications in this report in order to provide
adequate support for the proposed new structure. Anticipated depth of recompaction is
2 feet.
Conventional spread footings founded a minimum of 12 inches for one story structures
and 18 inches for two story structures below lowest adjacent grade and having a width
determined by the allowable soil bearing value as detailed above are recommended for
foundation support. Footing widths should be at least 12 inches for one story structures
or 15 inches for two story structures for continuous footings and 24 inches for square
footings due to practical considerations as well as Building Code requirements.
Reinforcing in footings should consist of at least one #4 steel bar placed continuously in
the top and bottom of continuous footings regardless of structural requirements.
Reinforcing for isolated footings are dictated by the structural requirements. These
recommendations are based upon on the soil type encountered and do not take into
consideration the proposed bearing load.
Concrete slabs-on-grade should be constructed to have a nominal thickness of 4" and
underlain with a sand blanket of 3 inches in thickness. Provide minimum temperature
reinforcement consisting of 6X6-10I10 welded wire mesh. The sand subbase (sand
blanket) should have a sand equivalent exceeding 30 per ASTM D2419. All slabs
should either have a conventional thickened edge or be poured monolithically with
continuous footings at the slabs perimeter. Conventional thickened edges should be 8"
thick at slab edge, uniformly tapering to 4" thick at 2' from slab edge. The thickened
edges or monolithic footings should extend completely around the slab's perimeter.
Construction and expansion joints should be considered slab edges. Maximum spacing
of expansion joints is 50' for interior slabs and 30' for exterior slabs.
2
Mike O'Gara File No. 9796 June 9, 1999
5. A representative sample of the foundation soil was remolded to 90% of maximum
dry density (127.3). Based on the following test results, a safe allowable bearing
value of at least 2500 pounds per square foot for 12 inch deep footings may be used
in designing the foundations and slab for the proposed structures. This value may be
increased by one third for wind and/or seismic loading.
Angle of internal friction 37°
Cohesion 227 psf
Unit weight 114.7 pcf
For any grading proposed or contemplated for this project, the following grading specifications
should be utilized.
RECOMMENDED GRADING SPECWICATIONS
For
Proposed Residential Building Site
Magnolia Avenue
City of Carlsbad
GENERAL: Soil Testers and 'Soil Engineer' are synonymous hereinafter and shall be
employed to inspect and test earthwork in accordance with these specifications, the accepted
plans, and the requirements of any jurisdictive governmental agencies They are to be allowed
adequate access so that the inspections and tests may be performed. The Soil Engineer shall be
appraised of schedules and any unforeseen soil conditions.
Substandard conditions or workmanship, inadequate compaction, adverse weather, or deviation
from the lines and grades shown on the plans, etc., shall be cause for the soil engineer to either
stop construction until the conditions are corrected or recommend rejection of the work. Refusal
to comply with these specifications or the recommendations and/or interpretations of the soil
engineer will be cause for the soil engineer and/or his representative to immediately terminate his
services.
Deviations from the recommendations of the Soil Report, from the plans, or from these
Specifications must be approved in writing by the owner and the contractor and endorsed by the
soil engineer.
SOIL TEST METHODS:
Maximum-Density & Opt Moisture
Density of Soil In-Place
- ASTMD1557-70
- ASTM D1556, D2922 and D3017
3
Mike O'Gara File No. 9796 June 9, 1999
Soil Expansion - UBC STANDARD 29-2
Shear Strength - ASTM D3080-72
Gradation & Grain Size - ASTM Dl 140-71
Capillary Moisture Tension - ASTM D2325-68
Organic Content - % Weight loss after heating for 24 hours
at 300° F and after deducting soil moisture.
LIMITING SOIL CONDITIONS:
Minimum Compaction '90% for 'disturbed soils. (Existing fill,
newly placed fill, plowed ground,, etc.)
84% for natural, undisturbed soils.
95% for pavement subgrade within 2' of
finish grade and pavement base course.
Expansive Soils Expansion index exceeding 20
Insufficient fines Less than 40% passing the #4 sieve.
Oversized Particles Rocks over 10" in diameter.
PREPARATION OF AREAS TO RECEIVE FILL:
Brush, trash, debris and detrimental soils shall be cleared from the areas to receive fill.
Detrimental soils shall be removed to firm competent soil. Slopes exceeding 20% should be
stepped uphill with benches 10' or greater in width. Scarify area to receive fill to 6" depth and
compact.
FILL MATERIAL shall not contain insufficient fines, oversized particles, or excessive
organics. On-site disposition of oversized rock or expansive soils is to be at the written direction
of the Soil Engineer. Select fill shall be as specified by the soil engineer. All fills shall be
compacted and tested.
SIJIBDRA1NS shall be installed if required by and as directed by and detailed by the soil
engineer and shall be left operable and unobstructed. They shall consist of 3" plastic perforated
pipe set in a minimum cover of 4" of filter rock in a 'vee' ditch to intercept and drain free ground
from the mass fills. Perforated pipe shall be schedule 40, Poly-Vinyl-Chloride or Aciylonitrile
Butadienne Styrene plastic. Rock filter material shall conform to the following gradation:
Sieve size: 3/4" #4 #30 #200
%Passing: 90-100 25-50 5-20 0-7
Subdrains shall be set at a minimum gradient of 0.2% to drain by gravity and shall be tested by
dye flushing before acceptance. Drains found inoperable shall be excavated and replaced.
51
Mike O'Gara File No. 9796 June 9, 1999
CAPPING EXPANSIVE SOILS: If capping expansive soils with non-expansive soil to
mitigate the expansive potential is used, the cap should be compacted, non-expansive, select soil
placed for a minimum thickness 3' over the expansive soil and for a minimum distance of 8'
beyond the exterior perimeter of the structure. Special precautions should be taken to ensure that
the non-expansive soil remains uncontaminated and the minimum thickness and dimensions
around the structure are maintained. The expansive soils underlying the cap of non-expansive
cap should be pre-saturated to a depth of 3' to obtain a degree saturation exceeding 90% before
any construction supported by the compacted cap.
The non-expansive soil comprising the cap should conform to the following:
Minimum Compaction 90%
Maximum Expansion Index 30
Minimum Angle of Internal Friction 33 Deg
Cohesion Intercept 100 psf
UNFORESEEN coNDmoNs: Soil Testers assume no responsibility for conditions which
differ from those described in the applicable current reports and documents for this property.
Upon termination of the soil engineer's services for any reason, his fees up to the time of
termination become due and payable. If it is necessary for the soil engineer to issue an
unfavorable report concerning the work that he has been hired to test and inspect, the soil
engineer shall not be held liable for any damages that might result from his 'unfavorable report'.
If we can be of any further assistance, please do not hesitate to contact our office. This
opportunity to be of service is sincerely appreciated.
Respectfully submitted,
jseph C. Smyth, RCE 2 V65
rrWrft 21.150
JCSIss ' 9130101
cc: (3) submitted
'kZC4OF CM.
5
w
CHRISTIAN WHEELER
ENGINEERING
December 6, 1999
Mike O'Gara
do Soil Testers
Post Office Box 1195
Lakeside, CA 92040
CWE 199.050.1
SUBJECT: Seismic Design Criteria, Proposed Residential Building Site, Magnolia Avenue,
Carlsbad, California
REFERENCES: 1) Site Inspection, Proposed Residential Building Site, Magnolia Avenue,
Carlsbad, California, Tract 9723, Phase I, by Soil Testers, Project No. 9796, dated June
9, 1999.
Maps of Known Active Fault Near-Source Zones in California and Adjacent
Portions of Nevada by California Division of Mines and Geology, dated February
1998.
Geologic Maps of the Northwestern Part of San Diego County, California by S. S.
Tan and M. P. Kennedy, California Division of Mines and Geology Open-File Report
96-02.
Dear Mr. O'Gara:
In accordance with the request of Soil Testers, we have prepared this letter to present pertinent
seismic/geotechnical information regarding the project site. The scope of our limited study consisted of a
review of the referenced soils report, a review of other pertinent literature, and the preparation of this letter
that includes our findings.
GENERAL GEOLOGIC SETTING: The project site is located in the Coastal Plains Physiographic
Province of San Diego County and is underlain by Quaternary-age terrace deposits and associated surficial
soils. The terrace deposits generally consist of light reddish-brown to yellowish-brown, medium dense to
dense sands and silty sands.
SEISMIC DESIGN PARAMETERS: Based on a maximum magnitude (Minax) earthquake of 6.9 along
the nearest portion of the Rose Canyon Fault Zone, the Maximum Bedrock Acceleration at the site would be
approximately 0.40 g. For structural design purposes, a damping ratio not greater than 5 percent of critical
dampening, and Soil Profile Type SD are recommended (IJBC Table 16-3). Based upon the location of the site
at approximately 8 kilometers from the Rose Canyon Fault Zone (Type B Fault), Near Source Factors Na
equal to 1.0 and N equal to 1.1 are also applicable. These values, along with other seismically related design
parameters from the Uniform Building Code (UBC) 1997 edition, Volume II, Chapter 16, utilizing a Seismic
Zone 4 are presented in tabular form below.
4925 Mercury Street + San Diego, CA 92111 + 858-496-9760 4 FAX 858-496-9758
C\'(' 199.050 December 6, 1999
UBC - CHAPTER 16
TABLE No.
SEISMIC
PARAMETER
RECOMMENDED
VALUE
16-I Seismic Zone Factor Z 0.40
16-J Soil Profile Type SD
16-Q Seismic Coefficient Ca 0.44 Na
16-R Seismic Coefficient C 0.64 N
16-S Near Source Factor Na 1.0
16-T Near Source Factor N. 1.1
16-U Seismic Source Type B
LIQUEFACTION: Liquefaction is the phenomenon that may result in large total and/or differential
ground surface settlement and possible lateral ground spreading during an earthquake. Liquefaction occurs
when loose, saturated, generally fine sands and silts are subject to strong ground shaking. The soil loses all
shear strength and becomes a viscous liquid for a short period of time, and then usually solidifies.
Settlement of the ground surface and failure of foundations caused by liquefaction is usually only affected
by the soils that liquefy within the upper 30 feet; the effect of liquefaction of soils below this depth is not
usually manifested at the ground surface. Four conditions usually must be present before liquefaction can
occur.
The soil is below the groundwater table, i.e., saturated;
The soil is composed predominantly of fine sand and silt;
The soil is in a loose to medium dense state;
The soil is subject to a sufficient magnitude and duration of strong ground shaking.
Based on the available information, it appears that the native materials at the site below the foundation
elevation are generally medium dense to dense and probably not subject to liquefaction.
If you have any questions after reviewing this letter, please do not hesitate to contact this office.
Respectfully submitted,
CHRISTIAN WHEELER ENGINEERING
Curtis it Burdett, C.E.G. #1090 qc 6
CRB:crb 1 I CE RED
o E.NNEERING
cc: (4) Soil Testers GEoLOGIST
P0 Box 1195 Exp.j2.
Lakeside, CA 92040
FROM O'GRR & CO. Frx NO. 760 4347563 Sep. 27 20 1 09:21PM P1 Y-.!-1(JU1 MU UO V!*t1L) iIV. IUV JUL UJJU I' '.1'
City of Carlsbad
Plumbing. Electrical Mechanical WirksheeJ
Project Address &dgodles
Permit No. C3rf1$'/
Questions below refer to work being done for this permit only.
Number of new or relocated fixtures, traps, or floor drains?
New building sewer lne
Number of roof drcs?
Install/alter water line?
Number OF water hears?
Number of hose bibs?
Gas pJping 5y5tern - ____
Number of new or relocated gas outlets
New water meter- No. of
Potable k irrigation
Number of new oanels or subpanels?
Size of New Service
single Phase Size Number of amperes
Three Phase Number of amperes
.e • Three Pa- 480 Number of amperes 0..
Remodel (relocate existing outlets/switches or add outle -No Yes No
Number of furnaces, A#, or heat pumps?
Number of flieplaces
Number of exhaust fars?
Number of exhaust hoods?
Number of boilers or compressors?
New or relocated du work?
a
Number of HP?
Yes '- No
BEFORE THE PERMIT CAN BE FEED OUT Till NEEDS TO U TO THE BUILDING
DEPARTMENT - F NU?l8jR (760) 602-8358
Yes _kf
Yes k No
4'.
Install Repair
Size
0
C8012754 1060 MAGNOLIA AV CBAD
O'GARA RES-2315 SF, 480 SF GAR
438 SF 2ND DWELLING UNIT
RESDNTL SFD
Lot: OGARA MICHAEL D&VICKI B
I
?
(/
-O /ck-.~-fC.
I C 6-c / ocø-j1
t1bt b (
PLANUM
.:7 /c__(_ /
• B4GIN1N
P1REAPPR/FORM
HEALTH DEPT
KM MAY/AIR Q&$L
- lymmeawmOOR
WI -
ftANOW
BIGNN
SCHOMFORM 7
ciocoiw
PGAUWORNufw
BLDG FEES COMM