Loading...
HomeMy WebLinkAbout1065 CARLSBAD VILLAGE DR; A; CBC2019-0361; PermitPrint Date: 12/12/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 1065 Carlsbad Village Dr, A BLDG-Commercial 2033202900 $123,902.64 Commercial Permit Work Class: Tenant Improvement Lot#: Reference #: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: (city of Carlsbad Permit No: CBC2019-0361 Status: Applied: Issued: Permit Fina led: Inspector: Final Closed -Finaled 07/22/2019 09/26/2019 Inspection: 12/12/2019 3:57:54Pr Description: COMMUNITY RESOURCE CENTER: 2664 SF Tl STORE TO STORE// COMBINING SUITES ( A-1, A-2, AND B) INTO SUITE A Owner: B R F I CARLSBAD LLC 11611 San Vicente Blvd Balboa Retail Part, 900 BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) LOS ANGELES, CA 90049 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-COMMERCIAL Total Fees: $1,478.73 Total Payments To Date: $1,478.73 Balance Due: $0.00 $711.20 $497.84 $89.00 $55.00 $86.00 $5.00 $34.69 Please take NOTICE that approval of your project includes the 11 lmposition11 of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application procesSing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov { Cicyof Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan Check C f?,L2.o1'i -036[ Est. Value1!. 12 '2,_ qoz_ ) PC Deposit --------- Date ±/2..V/1 ' JobAddress lo'15 Croi-Lssa:!', \J1LLA:eik b-e... Suite: /t/s 5?PN:etf~2'1-5I-OO Tenant Name: Cofvtl'II~ .\'.2c-s011t.CP cl\):bL CT/Project #: _________ Lot#: ___ _ Occupancy: M-'ge---};tt--d Construction Type: V-B . Fire Sprinklers: yes!@ Air Conditioning: @ / no BRIEF DESCRIPTION OF WORK: *4)>.•/1:Nt: )11.1 ftz.◄21 )(2:r\ fh +( \\ 1e,, I ~Ml I :&h--,>Ur D Addition/New: ___________ .New SF and Use, ___________ New SF and Use, ___ Deck SF, Patio Cover SF (not including flatwork) ~enant Improvement: 'l&(,, 1 SF, _____ SF, Existing Use ~IL Proposed Use k~\l- Existing Use ______ Proposed Use _____ _ □ Pool/Spa: _____ SF Additional Gas or Electrical Features? ___________ _ D Solar: ___ KW, __ Modules, ___ Mounted, Tilt: Yes/ No, RMA: Yes/ No, Panel Upgrade: Yes/ No ~lumbing/Mechanical/Electrical Only: _________________________ _ □ Other: Lo Mt, ; ,1.,e DESIGN PROFESSIONAL Name: $A:'.)Ntlq k$ Aafl: CMµ\.-- Address: _______ ~\ _______ _ City: _______ State: ___ ,Zip: ___ _ CONTRACTOR BUSINESS Name: TW WH:<+e C 01.J',ffi}LhW Address: --Z ')2~/ G,4kt v4---, (c✓.J City: C.:i-n{fbae/ State: C4 Zip: 57CcJ9 Phone: ________________ _ Email: ________________ _ Phone: ft fJ_r-j_rf;_o Email: tZw:, C.o,,vJfrr, c/.,4,.,,NC--Co C"-. Architect State License: __________ _ State License: JozJ:e"5.~ Bus. License: l5'LJJ f QO c) 'ii'! -6 7. (Sec. 7031.S Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). -7vr7 1635 Faraday Ave Carlsbad, CA 92008 B-2 Ph: 760-602-2719 Fax: 760-602-8558 Page 1 of 2 Email: Building@carlsbadca.gov Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: hearby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the ork which this permit is issued. 'a(, have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. C';, workers' compensation insurance carrier and policy number are: Insurance Company Name: 5'1-'4-k, (A JM;?b..t JJl,'Vw I fJSVll.A-AICe Fi,,,,-..,() Policy No. 'JV{?n "!/, -('J Expiration Date: I {c /7 rJ2 o 1 0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of Calif rnia. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.0 addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. ( OPTION B ): OWNER-BUILDER DECt'ARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: □ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). □ I am exempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. I {have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work {include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated {include name/ address/ phone/ type of work): OWNER SIGNATURE: __________________ □AGENT DATE: _____ _ CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: _____________________ _ lender's Address: _____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AG REE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CllY OF CARLSBAD AGAINST ALL LIABILmES, JUDGMENTS, COSlSAND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAJNSTSAJDCJTY JN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 1 ection 1 . Uniform Building Code). 1635 Faraday Ave Carlsbad, CA 92008 B-2 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 , · ;PERMIT INSPECTION HISTORY REPORT (CBC2019-0361) ' ' -Jt ' ~ ' )I ' Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed -Finaled Scheduled Date Actual Start Date Inspection Type Application Date: 0712212019 Owner: B R F I CARLSBAD LLC Issue Date: 09/2612019 Subdivision: TOWN OF CARLSBAD AMENDED Expiration Date: 06/0812020 Address: 1065 Carlsbad Village Dr, A Carlsbad, CA 92008-1884 IVR Number: 20525 Inspection No. Inspection Status Primary Inspector Reinspection Complete ----···----·-·----------------------------------- 1211012019 12/1012019 BLDG-Final Inspection 12/1112019 1211112019 BLDG-Final Inspection 1211212019 12/12/2019 BLDG-Final Inspection 113199-2019 Checklist ltem BLDG-Building Deficiency 113372-2019 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency 113598-2019 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Electrical Final Failed Michael Collins COMMENTS See card for interior pick up at restroom, break room and accessible parking. No roof access. Partial Pass Michael Collins COMMENTS See card for interior pick up at restroom, break room and accessible parking. No roof access. Partial, see card for HVAC pick up. Passed Michael Collins COMMENTS See card for interior pick up at restroom, break room and accessible parking. No roof access. Partial, see card for HVAC pick up. Relnspection Passed No Reinspection Passed No Yes Passed No Yes Yes Yes Yes Yes Complete Incomplete Complete ---·-····---··--·--·-•--··~-----------·----------------------- December 12, 2019 Page 2 of 2 PERMIT INSPECTION HIS"{ORY REPORT (CBC2019-0361) Permit Type: BLDG-Commercial Application Date: 07/22/2019 Owner: Work Class: Tenant Improvement Issue Date: 09/26/2019 Subdivision: Status: Closed -Finaled Expiration Date: 06/08/2020 Address: IVR Number: 20525 Scheduled Actual Date Start Date Inspection Type Inspection No. 1011812019 1011812019 BLDG-21 107932-2019 Underground/LI nderf loor Plumbing Checklist Item BLDG-Building Deficiency 10125/2019 10/25/2019 BLDG-84 Rough 108811-2019 Combo(14,24,34,44) Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks} BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers 10/2912019 10/2912019 BLDG-44 109035-2019 Rough/DuctsfDampe rs Checklist Item BLDG-Building Deficiency 11104/2019 1110412019 BLDG-82 Drywall, 109643-2019 Exterior Lath, Gas Test, Hot Mop Checklist Item BLDG-17 Interior Lath-Drywall BLDG-23 Gas-Test-Repairs 1111412019 11114/2019 BLDG-44 110509-2019 Rough/Ducts/Dampe rs Checklist Item BLDG-Building Deficiency 1111512019 11115/2019 BLDG-85 T-Bar, Celling Grids, Overhead 111112-2019 December 12, 2019 Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks} BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers Inspection Status Primary Inspector Passed Peter Dreibelbis COMMENTS Passed Paul York COMMENTS Passed Luke Storno COMMENTS Passed Tony Alvarado COMMENTS Partial Pass Paul York COMMENTS Passed Paul York COMMENTS B R F I CARLSBAD LLC TOWN OF CARLSBAD AMENDED 1065 Carlsbad Village Dr, A Carlsbad, CA 92008-1884 Reinspection Complete Complete Passed No Complete Passed Yes Yes Yes Yes Yes Complete Passed No Complete Passed Yes Yes Re inspection Incomplete Passed No Complete Passed Yes Yes Yes Yes Yes Page 1 of 2 f. lPCD ~ ... ----·---CHITY If Ill IIHO 10124 OLD GROVE ROAD SAN DIEGO, CA 92131 PHONE: (858) 586-2650 apcdcomp@sdcounty.ca.gov APCD2019-ASB-001063 Submitted: Sep 19, 2019@ 3:01 PM NOTIFICATION: ASBESTOS REMOVAL, RENOVATION, AND DEMOLITION OPERATIONS Project Type: Renovation (Removal) Facility Name: Community Resource Center Facility Location: 1065 Carlsbad Village Dr. Suites A 1, A2, B, Carlsbad, CA 92008, (760) 753-8300 Faclllty Owner: BRFI Carlsbad, LLC, 11611 San Vicente Blvd Suite 900. Los Angeles, CA 90049, (310) 496-4135 Renovation -Start Date: Thursday, Oct 3, 2019 Demolition -Start Date: Type Category Acoustic/Popcorn Ceiling Friable Vinyl floor tiles Category I Non-friable Asbestos to be removed:~ Condition Good Good End Date: Friday, Oct 11, 2019 End Date: Removal Method Hand tools Hand tools Amount 1500 150 Regulated y N •Asbestos Surveys are required prior to Renovation or Demolition. A copy of the survey must be maintained on site for the duration of the project. Survey not conducted because suspect materials presumed to contain asbestos (asbestos to be handled/disposed of per Rule 1206). Survey Conducted: ~ Date Conducted: Mar 3 2019 Asbestos Present: Y!!§. TIiie: Survey Company: ECS Environmental Certification: Certified Asbestos Consultant (CAC) Surveyor: Bond McCowan Certification Num: 12-4865 Certification Exp Date: Mar 7, 2020 Detection Procedures: Bulk Sampling/ PLM Asbestos Work Practices: 3 Stage Deacon/ Amended Water I Critical Barriers/ Full Containment/ HEPA Vacuum/ Negative Air Machines/ Water ACM Disturbed by Demolition: RACM Remain in Building: t:llA Demolition with Category I Materials: t:llA Category I / Category II Materials: 1'il/\ Demolition Work Practices: Commercial All RACM Previously Removed: ~ Supporting Structural Members Demolished: WA Demolition with Category II Materials: N/A Isolate Area / Keep wet, contained and notify APCD if greater than 20%. / Post Signs/ APC294_ Online_Asbestos_Submission_Notification v1 .0 (03/2019) Commercial Page 1 of2 AP-CD -----CIHTf If UI IIEIO Asbestos Transporter: 10124 OLD GROVE ROAD SAN DIEGO, CA 92131 PHONE: (858) 586-2650 apcdcomp@sdcounty.ca.gov Business Name: Watkins Environmental Address: 8291 Aero Place Suite 160, San Diego, CA 92123 Asbestos Landfill: Business Name: South Yuma County Landfill Address: 19536 South Avenue 1E, Yuma, /JiZ. 85365 Certifies all of the following: APCD2019-ASB-001063 Submitted: Sep 19, 2019@3:01 PM_ Phone: (858) 268-1500 Phone: (928) 341-9300 1. An individual trained in accordance with District Rule 1206(f)(8) will be on site during asbestos removal; and, 2. Documentation that the required training has been completed and is current will be made available to the District upon request; and, 3. The information on this notification is complete and correct and I am accepting legal responsibility for the information on this form. Original notifications must be submitted to the District at least 10 working days prior to removal or demolition. Revised notifications must be submitted prior to the original start date. The District must receive payment by close of business of the next working day after the effective date of the notification. The District considers submitted Notifications (original and revised) without the required fee(s) as stated in Rule 40(f)(2) to be considered invalid. Notifications shall expire within 365 days from the effective date. APC294_ Online_Asbestos_Submission_Notification v1 .0 (03/2019) Page 2 of2 DATE: August 21, 2019 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2019-0361 ✓• EsG1I A SAH:bu1lt Co1npany SET: II PROJECT ADDRESS: 1065 Carlsbad Village Dr PROJECT NAME: T.I. for Community Resource Center ~ APPLICANT 1 JURIS. ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: Mail Telephone 0 REMARKS: By: Abe Doliente EsGil I (bygt\ Telephone#: Email: Fax In Person Enclosures: 8/12/19 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: August 1, 2019 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2019-0361 ✓• EsG1I A SAFEbuitrCompany SET: I PROJECT ADDRESS: 1065 Carlsbad Village Dr PROJECT NAME: T.I. for Community Resource Center D APPLICANT D JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. IZJ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. IZJ The applicant's copy of the check list has been sent to: Baker Architecture; Tony Kerleshi D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Tony Kerleshi Telephone#: 619-281-5937 Date contacted: (by: ) Email: tony@bakerarchitecture.com Mail Telephone Fax In Person 0 REMARKS: By: Abe Doliente/MB/CR EsGil 7/25/19 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBC2019-0361 August 1, 2019 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK#.: CBC2019-0361 JURISDICTION: Carlsbad OCCUPANCY: M USE: Store TYPE OF CONSTRUCTION: VB ACTUAL AREA: 2664 SF (T.I. only) ALLOWABLE FLOOR AREA: nc (existing) STORIES: 1 HEIGHT: nc SPRINKLERS?: No REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: August 1, 2019 FOREWORD (PLEASE READ): OCCUPANT LOAD: 33 DATE PLANS RECEIVED BY ESGIL CORPORATION: 7/25/19 PLAN REVIEWER: Abe Doliente/MB/CR This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC2019-0361 August 1, 2019 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Abe Doliente/MB/CR BUILDING ADDRESS: 1065 Carlsbad Village Dr BUILDING OCCUPANCY: M PLAN CHECK#.: CBC2019-0361 DATE: August 1, 2019 BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier T.I. 2664 46.51 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance -----------. . _.ru 1997 UBC Buildin g Permit Fee 1997 UBC Plan Check Fee Type of Review: D Repetitive Fee ·a:1 Repeats ~ Comments: '"" Complete Review □ Other 0 Hourly EsGII Fee Reg. VALUE ($) Mod. 123,903 123,903 □ Structural Only 1---------ll Hr. @ * Sheet 1 of 1 Carlsbad CBC2019-0361 August 1, 2019 GENERAL Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects .. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 1. Each sheet of the plans must be signed by the person responsible for their preparation, even if there are no structural changes. California State Law. Signatures on the final sets of plans will be verified before they are approved. 2. Plans and calculations shall be signed by the California state licensed engineer or architect where there are structural changes to existing buildings or structural additions. Please include the California license number, seal and date plans are signed. California Business and Professions Code. Signatures on the final sets of plans will be verified before they are approved. 3. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: ♦ Occupancy Classification: M ♦ Description of Use: Store ♦ Type of Construction: VB ♦ Sprinklers: No ♦ Stories 1 ♦ Height: nc ♦ Floor Area: nc ♦ Occupant Load: 33 INTERIOR WALL AND CEILING FINISHES 4. Provide a note on the plans or on the finish schedule, stating, "Wall and ceiling materials shall not exceed the flame spread classifications in IBC Table 803.11." Carlsbad CBC2019-0361 August 1, 2019 MISCELLANEOUS LIFE/SAFETY 5. Per California law, additions or alternations of Commercial projects available for use before January 1, 1994 may require replacement of noncompliant plumbing fixtures *** by water conserving fixtures: • An alternation or improvement to a room containing noncompliant fixtures (regardless of valuation). Please note on the plans the specific plumbing fixtures requiring replacement. *** "Noncompliant plumbing fixtures" are any of the following: • Any water closet exceeding 1.6 gallons/flush. • Any urinal manufactured to use more than 1.0 gallon/flush. • Any showerhead exceeding 2.5 gallon/minute. • Any interior faucet that emits more than a 2.2 gallons/minute. ACCESSIBILITY 6. Compliance with the disabled access requirements are already on the plans. These will be field verified by the City Building Inspector. ADDITIONAL 7. Please recheck the references called out on the unisex floor plan on sheet A4 of the plans. 8. Please see the following Electrical, Energy, Plumbing and Mechanical corrections. 9. To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 10. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: □ Yes □ No 11. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Abe Doliente/MB/CR at Esgil. Thank you. Carlsbad CBC2019-0361 August 1, 2019 ELECTRICAL, and ENERGY COMMENTS PLAN REVIEWER: Morteza Beheshti ELECTRICAL (2016 CALIFORNIA ELECTRICAL CODE) 1. Provide a single line diagram For fault current mitigation, describe the electrical distribution equipment design as "engineered", "fully rated" or "series rated". Include the AIC specification rating of overcurrent devices throughout the system. ENERGY (2016 CALIFORNIA BUILDING ENERGY STANDARDS) 2. Please include all luminaires shown on lighting plans on the luminaire schedule and energy compliance forms. Note: If you have any questions regarding this Electrical and Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. PLUMBING AND MECHANICAL COMMENTS PLAN REVIEW NUMBER: cbc2019-361 PLAN REVIEWER: Connor Reuss SET: I PLUMBING (2016 CALIFORNIA PLUMBING CODE) 3. State the slope of the condensate waste pipe on sheet P1. 4. Describe the method of compliance for temperature limitations for the following fixture types: public use lavatories limited to 110 degrees F per Energy Standards 11 0(c)(3) Note: The water heater thermostat may not be used for compliance. 5. Please review the prosed vent sizing for the entire building. For each drainage piping system connected to the public sewer that is vented by one or more vent pipes, the combination of the cross-sectional area of all vents that terminate through the roof cannot be less than the cross-sectional area of the largest waste pipe in the drainage system (in this case 4" waste pipe). Note: The cross- sectional area of a 4" diameter waste pipe is 12.57 sq. in. The cross-sectional area of a 2" diameter vent pipe is 3.14 sq. in. CPC 904.1 Carlsbad CBC2019-0361 August 1, 2019 6. It appears the building 1 ¼" water pipe may be undersized if it also feeds adjacent tenants. Provide complete water line sizing calculations: Include the water pressure, pressure loss calculations, water demands (for all fixtures connected to the 1 ¼" pipe), and the developed pipe lengths. CPC 610.0 or Appendix 'A'. Note: An approved pressure regulator is required where the static water pressure from the water supply piping exceeds 80 psi. Please address. CPC 608.2 7. Specify if any natural gas-powered appliances are under this permit. If so, please provide the proper CPC 1216.2 Table, the total developed length, and the load for each appliance. CPC 1216.0 MECHANICAL (2016 CALIFORNIA MECHANICAL CODE) 8. Please show the required 42 inches tall "Guards" (guard rails) or building parapets height where appliances, mechanical equipment, fans, roof hatch openings or other components that require service are located within 10 feet of a roof edge or open side of a walking surface. CBC 1015.6 & 1015. 7 9. Specify compliance with CMC 603.4.1 for length limitations for factory made flexible air ducts (5') and use (not to be used for rigid elbows or fittings). Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Connor Reuss at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. D □IJIJ 7490 OPPORTUNIY RD., STE 3500 SAN DIEGO, CA 92111 & ASSOCIATES (619) 260-0057 CONSULTING ENGINEERS STRUCTURAL CALCULATIONS FOR r~--~ .. ,,, .. CRC RELOCATION T.I. 1 L , JUL 2 2 2019 C!TYC. EJLi'.:.: .. ·: CLIENT= BAKER ARCHITECTURE DA TE ISSUED= 2019-07-18 7/18/2019 ATC Hazards by Location L\TC Hazards by Location Search Information Address: Coordinates: Elevation: Timestamp: Hazard Type: Reference Document: Risk Category: 1065 Carlsbad Village Dr, Carlsbad, CA 92008, USA 33.1624144, -117.3423894 77 ft 2019-07-18T17:35:21.8702 Seismic ASCE7-10 Site Class: D National MCER Horizontal Response Spectrum Design Horizontal Response Spectrum Sa(g) 1.00 0.80 0.60 0.40 0.20 0.00 o 2 Basic Parameters Name Value Ss 1.142 s, 0.438 SMs 1.191 SM1 0.684 Sos 0.794 So1 0.456 Sa(g) 0.60 0.40 0.20 0.00 4 6 8 Period (s) Description MCER ground motion (period=0.2s) MCER ground motion (period=1.0s) Site-modified spectral acceleration value Site-modified spectral acceleration value Numeric seismic design value at 0.2s SA Numeric seismic design value at 1.0s SA •Additional Information Name soc Value D 1.043 1.562 Description Seismic design category Site amplification factor at 0.2s Site amplification factor at 1.0s o 2 4 6 8 Period (s) https://hazards.atcouncil.org/#/seismic?lat=33.1624144&Ing=-117.3423894&address=1065 Carlsbad Village Dr%2C Carlsbad%2C CA 9f098%2C USA -~ 1/2 ; '· 7/18/2019 CRs CR1 PGA FPGA PGAM TL SsRT SsUH SsD S1RT S1UH S1D PGAd 0.945 0.997 0.451 1.049 0.473 8 1.142 1.208 1.507 0.438 0.44 0.605 0.571 ATC Hazards by Location Coefficient of risk (0.2s) Coefficient of risk (1.0s) MCEG peak ground acceleration Site amplification factor at PGA Site modified peak ground acceleration Long-period transition period (s} Probabilistic risk-targeted ground motion (0.2s) Factored uniform-hazard spectral acceleration (2% probability of exceedance in 50 years) Factored deterministic acceleration value (0.2s) Probabilistic risk-targeted ground motion (1.0s) Factored uniform-hazard spectral acceleration (2% probability of exceedance in 50 years) Factored deterministic acceleration value (1.0s) Factored deterministic acceleration value (PGA) The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are provided by the U.S. Geological Survey Seismic Design Web Services. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. https:/lhazards.atcouncil.org/#/seismic?lat=33.1624144&lng=-117 .3423894&address=1065 Carlsbad Village Dr%2C Carlsbad%2C CA 92008%2C USA 2/2 Roof Top Mechanical Unit -Lateral Analysis Project: CRC RELOCATION H= W= L= Mechanical Dimensions 2.75 ft 3.75 ft 6.17 ft Building Roof Line 15 ft Seismic Loads Fp = 0.4ap;:_swp (l + 2( f )) Ip Sos= W,= z= h= I= 0.794 g 600 lbs 2.5 6.0 15 15 1.0 762.24 lbs 143 lbs Wind Load F = qzGCrAr !Fp= qz = 0.00256 • KzrKzKv V2 I Exposure= B Z= 17.75 Wunit 26 psf per ASCE7-10 (13.3.1) per ASCE7-10 Table 13.6-1 per ASCE7-10 Table 13.6-1 238 lbs per ASCE7-10 29.5 ZG= 1200 ft per ASCE7-10 Table 26.9.1 per ASCE7-10 Table 26.9.1 per ASCE7-10 Table 29.3-1 per ASCE7-05 Table 26.6-1 qZ= G= Cf= Af= a= 7.0 KZ= KD= KZT= I= 0.60 0.85 1.0 1.0 V= 115 mph 17.40818243 lbs/ft2 0.85 1.05 16.95833333 ft2 per ASCE7-10 29.5-1-29.5-3 h= D= h/D= Force= Force Per Side= Uplift= 1/2" Diam Lag=> Embeddment= Capacity= 17.75 3.75 4. 733333333 !F= Wind Governs Anchorage 263 lbs 131 lbs 96 lbs 378 lbs/in 2 in 756 lbs > OK 263 lbs 96 lbs Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Description : Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-10 Material Properties Analysis Method: Allowable Stress Design Load Combination ASCE 7-10 Wood Species Wood Grade : Douglas Fir -Larch : No.2 Project Title: Enijineer: ProIect Descr: Fb-Tension Fb-Compr Fe -Prll Fe -Perp Fv Ft Beam Bracing : Beam is Fully Braced against lateral-torsional buckling •• Span~ 8.0 ft 900 psi 900 psi 1350 psi 625 psi 180 psi 575 psi Project ID: E : Modulus of Elasticity Ebend-xx 1600 ksi Eminbend -xx 580ksi Density 31.2pcf I 'ff02f ~-Plieiji,1fflaDl,~Bl!ii~":ill!IL. I I !iluc*~· !:c.··•·:.._" _______ S:..•:.._rv_ic.::.•:.._l:.._o:..ad::_:s:.._•:.._n.:.t•:.._r•:..d::..·.::L.::.o•:..d:_F:.._a:::cc_to'-rs:...:.w.:.ill__:b..:.•..:•"'P"Pl.:.:iec:d..:fo:..r__:c::..a.:.:lc.:.u.c.la.::.tio:.:n:.::sc__. Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load: D = 0.0260 ksf, Extent= 0.9150 -» 7.085 ft, Tributary Width= 4.0 ft, (NEW MECH'L UNIT) Uniform Load: D = 0.020 ks/, Tributary Width= 1.0 ft, (ROOF DL) Uniform Load : Lr= 0.020 ksf, Extent= 0.0 --» 0.9150 ft, Tributary Width = 1.0 ft, (ROOF LL) Uniform Load: Lr= 0.020 ksf, Extent= 7.085 --» 8.0 ft, Tributary Width = 1.0 ft, (ROOF LL) Point Load: E = 0.0960 k@0.9150 ft, (UPLIFT) ijlbnllfflflQM~41, lffliwill#,i' I Maximum Bending Stress Ratio 0.634 1 Maximum Shear Stress Ratio · Section used for this span 4x6 fb : Actual = 667 .69psi Section used for this span fv: Actual FB: Allowable = 1,053.00psi Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Do'Nl1ward Total Deflection Max Upward Total Deflection ----- = +D+H 4 000ft Span# 1 0.008 in 0.000 in 0.151 in 0.000 in Ratio= Ratio= Ratio= Ratio= •.•i'M~'iclm!i~9rc.~~+;str'°,~~t;lra1Yiiti(b1nation11~.~~ load Combination Max Stress Ratios Fv : Allowable Load Combination Location of maximum on span Span# where maximum occurs 12100>=360 0<360 636 >=240. 0<240.0 Moment Values Segment length Span# M V Cd C FN C; Cr Cm Ct CL M lb +O+H Length= 8.0 ft 0.634 0.196 0.90 1.300 1.00 1.00 1.00 1.00 1.00 0.98 667.69 +O+L+H 1.300 1.00 1.00 1.00 1.00 1.00 Length= 8.0 ft 0.571 0.176 1.00 1.300 t.00 1.00 1.00 1.00 1.00 0.98 667.69 +O+Lr+H 1.300 1.00 1.00 1.00 1.00 1.00 Length = 8.0 ft 0.460 0.144 1.25 1.300 1.00 t.00 1.00 1.00 1.00 0.99 673.38 = = = F'b 0.00 1053.00 0.00 1170.00 0.00 1462.50 Design OK V 0.00 0.41 0.00 0.41 0.00 0.42 0.196: 1 4x6 31.71 psi 162.00 psi +O+H 7.562ft Span# 1 Shear Values Iv 0.00 _I F'v 0.00 31.71 162.00 0.00 0.00 31.71 180.00 0.00 0.00 32.45 225.00 Tille Block Line 1 You can change this area using the "Settings" menu item and then using the 'Printing & Title Block' selection. Tille Block Line 6 Description : (N) SUPPORT BEAM Load Combination Max Stress Ratios Segment Length Span # M V Cd C FN C i Cr +O+S+H 1.300 1.00 1.00 Length=8.0ft 0.496 0.153 1.15 1.300 1.00 1.00 +0+0.750Lr+0.750L+H 1.300 1.00 1.00 Length= 8.0 ft 0.459 0.143 1.25 1.300 1.00 1.00 +0+0.750L+0.750S+H 1.300 1.00 1.00 Lenglh=8.0fl 0.496 0.153 1.15 1.300 1.00 1.00 +0+0.60W+H 1.300 1.00 1.00 Length= 8.0 fl 0.357 0.110 1.60 1.300 1.00 1.00 +0+0.70E+H 1.300 1.00 1.00 Lenglh=8.0fl 1 0.368 0.126 1.60 1.300 1.00 1.00 +0+0.750Lr+0.750L+0.450W+H 1.300 1.00 1.00 Length=8.0fl 1 0.359 0.112 1.60 1.300 1.00 1.00 +0+0.750L+0.750S+0.450W+H 1.300 1.00 1.00 Lenglh=8.0fl 1 0.357 0.110 1.60 1.300 1.00 1.00 +0+0.750L+0.750S+0.5250E+H 1.300 1.00 1.00 Lenglh=8.0fl 1 0.365 0.122 1.60 1.300 1.00 1.00 +0.60D+0.60W+0.60H 1.300 1.00 1.00 Length= 8.0 fl 0.214 0.066 1.60 1.300 1.00 1.00 +0.60D+0.70E+0.60H 1.300 1.00 1.00 Length= 8.0 ft 1 0.225 0.082 1.60 1.300 1.00 1.00 Cm 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Project Tille: Engineer: Pro1ect Descr: CI CL 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 !ilrv,irlillflguii'i1))JDJlllffl!fii1\i':([ l~il!c'~~t"'!:111l)j1f1~;~i:,i'"3lll". !!:_" ---~~ Load Combination Load Combination ~pan Max.•.• Defl Location in Span +0+0.70E+H 1 0.1507 4.000 ·~!~~V&ifH!iJJDaciiOnlllll'.~f,:.:-·>: :/}~.~~;,. ,;;·'.;;,~6:):~-Support notation Far left is #1 Project ID: Moment Values Shear Values M lb F'b V fv F'v 0.00 0.00 0.00 0.00 0.98 667.69 1345.50 0.41 31.71 207.00 0.00 0.00 0.00 0.00 0.99 671.96 1462.50 0.41 32.27 225.00 0.00 0.00 0.00 0.00 0.98 667.69 1345.50 0.41 31.71 207.00 0.00 0.00 0.00 0.00 0.98 667.69 1872.00 0.41 31.71 288.00 0.00 0.00 0.00 0.00 1.01 688.76 1872.00 0.47 36.35 288.00 0.00 0.00 0.00 0.00 0.99 671.96 1872.00 0.41 32.27 288.00 0.00 0.00 0.00 0.00 0.98 667.69 1872.00 0.41 31.71 288.00 0.00 0.00 0.00 0.00 1.01 683.45 1872.00 0.45 35.19 288.00 0.00 0.00 0.00 0.00 0.59 400.61 1872.00 0.24 19.03 288.00 0.00 0.00 0.00 0.00 0.62 421.78 1872.00 0.30 23.66 288.00 Max."+" Oefl Location in Span 0.0000 0.000 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum ------'-""o_-47~7-~o~.4-36~---------------------- 0verall MINimum 0.018 0.011 +O+H 0.418 0.418 +O+L+H 0.418 0.418 +O+Lr+H 0.436 0.436 +O+S+H 0.418 0.418 +0+0.750Lr+0.750L +H 0.431 0.431 +0+0.750L+0.750S+H 0.418 0.418 +0+0.60W+H 0.418 0.418 +0+0.70E+H 0.477 0.425 +0+0.750Lr+0.750L +0.450W+H 0.431 0.431 +0+0.750L+0.750S+0.450W+H 0.418 0.418 +0+0.750L+0.750S+0.5250E+H 0.462 0.423 +0.60D+0.60W+0.60H 0.251 0.251 +0.60D+0.70E+0.60H 0.310 0.258 D Only 0.418 0.418 Lr Only 0.018 0.018 LOnly SOnly WOnly E Only 0.085 0.011 H Only SAN DIE HAZARDb QUESTIONNAIRE OFFICE USE ONLY RECORO ID# __ =~~~~~-~-~------I PLAN CHECK #_c.:"""'-lue,J'c'-"'2 ... oLL, ..... 1_-_,o"'--'1"'6:..1.t _____ l BP DATE he following questions represe t the facili 's activities, NOT the specific project description. PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San Diego): Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives 2. Compressed Gases 3. Flammable/Combustible Liquids 6. Oxidizers 10. Cryogenics 7. Pyrophorics 11. Highly Toxic or Toxic Materials 8. Unstable Reactives 12. Radioactives ~, Other Health Hazards ~ None of These. 4. Flammable Solids PART 11: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION HMD : II the answer to any of the questions is yes, applicant must contact the County o San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, an Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. 0 CalARP Exempt I FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: YES ~ (for new construction or remodeling projects) 1. D M..,.....ls your business listed on the reverse side of this form? (check all that apply). Date Initials 2. D 0" Will your business dispose of Hazardous Substances or Medical Waste in any amount? 0 CalARP Required I 3. D 9" Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 4. 5. 6. 7. 8. □ □ □ □ □ pounds and/or 200 cubic feet? 12( Will your business store or handle carcinogens/reproductive toxins in any quantity? g:. Will your business use an existing or install an underground storage tank? ~ Will your business store or handle Regulated Substances (CalARP)? ig" Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? ~ Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or reater than 1,320 allons? California's Above round Petroleum Stora e Act . Date Initials 0 CalARP Complete I Date Initials PART 111: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES• answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 apcdcomp@sdcounty.ca.gov (858) 586-2650). (*No stamp required if 01 Yes and Q3 Yes and 04-06 No]. The following questions are intended to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except -those with more than one building+ on the property; single buildings with more than four dwelling units; townhomes; condos; mixed-commercial use; deliberate burns; residences forming part of a larger project. [ .. Excludes garages & small outbuildings.] YES NO i J ~ 4. 5. 6. □ □ □ □ ~ □ Will the project disturb 160 square feet or more of existing building materials? Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification may be required 1 O working days prior to commencing asbestos removal. Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet (www.sdapcd.org/info/factstpermits.pd!) for typical equipment requiring an APCD permit. (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school bounda Si nature of Owner or Authorized A ent FOR OFFICAL USE ONLY: I I Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: ________________________________ _ BY· DATE / I EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD* APCO COUNTY-HMO APCO COUNTY-HMO APCD *A stamp in this box only exempts businesses from completing or updating a Hazardous Matenals Business Plan. Other permIttIng requirements may still apply. HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division LIST OF BUSINESSES WHICH REQUIRE REVIE~~. . -. . · THE COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL H U ATERIALS DIVISION ~ . . . . ,, Check all that apply: AUTOMOTIVE CHEMICAL HANDLING OTHERS AND MISCELLANEOUS D Battery Manufacturing/Recycling D Boat Yard D CarWash D Dealership Maintenance/Painting D Machine Shop D Painting D Radiator Shop D Rental Yard Equipment D Repair/Preventive Maintenance D Spray Booth D Transportation Services D Wrecking/Recycling CHEMICAL HANDLING D Agricultural supplier/distributor D Chemical Manufacturer D Chemical Supplier/Distributor D Coatings/Adhesive D Compressed Gas Supplier/Distributor D Dry Cleaning D Fiberglass/Resin Application D Gas Station D Industrial Laundry D Laboratory D Laboratory Supplier/Distributor 0 Oil and Fuel Bulk Supply D Pesticide Operator/Distributor D Photographic Processing D Pool Supplies/Maintenance D Printing/Blue Printing D Road Coatings D Swimming Pool 0 Toxic Gas Handler D Toxic Gas Manufacturer METAL WORKING D Anodizing D Chemical Milling/Etching D Finish-Coating/Painting D Flame Spraying D Foundry D Machine Shop-Drilling/Lathes/Mills D Metal Plating D Metal Prepping/Chemical Coating D Precious Metal Recovery D Sand Blasting/Grinding D Steel Fabricator D Wrought Iron Manufacturing AEROSPACE D Aerospace Industry D Aircraft Maintenance D Aircraft Manufacturing D Asphalt Plant D Biotechnology/Research D Chiropractic Office D Co-Generation Plant 0 Dental Clinic/Office D Dialysis Center 0 Emergency Generator D Frozen Food Processing Facility D Hazardous Waste Hauler D Hospital/Convalescent Home D Laboratory/Biological Lab 0 Medical Clinic/Office D Nitrous Oxide (NO,) Control System D Pharmaceuticals 0 Public Utility D Refrigeration System D Rock Quarry D Ship Repair/Construction D Telecommunications Cell Site D Veterinary Clinic/Hospital D Wood/Furniture Manufacturing/Refinishing ELECTRONICS D Electronic Assembly/Sub-Assembly D Electronic Components Manufacturing 0 Printed Circuit Board Manufacturing NOTE: THE ABOVE LIST INCLUDES BUSINESSES, WHICH TYPICALLY USE, STORE, HANDLE, AND DISPOSE OF HAZARDOUS SUBSTANCES. ANY BUSINESS NOT INCLUDED ON THIS LIST, WHICH HANDLES, USES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE HAZARDOUS MATERIALS DIVISION (HMD) REVIEW OF BUSINESS PLANS. FOR MORE INFORMATION CALL (858) 505-6880. LIST OF AIR POLLUTION CONTROL DISTRICT PERMIT CATEGORIES Businesses, which include any of the following operations or equipment, will require clearance from the Air Pollution Control District. CHEMICAL 47 -Organic Gas Sterilizers 32 -Acid Chemical Milling 33 -Can & Coil Manufacturing 44 -Evaporators, Dryers & Stills Processing Organic Materials 24 -Dry Chemical Mixing & Detergent Spray 'Towers 35 -Bulk Dry Chemicals Storage 55 -Chrome Electroplating Tanks COATINGS & ORGANIC SOLVENTS 27 -Coating & Painting 37 -Plasma Arc & Ceramic Deposition Spray Booths 38 -Paint, Stain & Ink Mfg 27 -Printing 27 -Polyester Resin/Fiberglass Operations METALS 18 -Metal Melting Devices 19 -Oil Quenching & Salt Baths 32 -Hot Dip Galvanizing 39 -Precious Metals Refining ORGANIC COMPOUND MARKETING (GASOLINE, ETC) 25 -Gasoline & Alcohol Bulk Plants & Terminals 25 -Intermediate Refuelers 26 -Gasoline & Alcohol Fuel Dispensing COMBUSTION 34 -Piston Internal -Combustion Engines 13 -Boilers & Heaters (1 million BTU/hr or larger) 14 -Incinerators & Crematories 15 -Burn Out Ovens 16-Core Ovens 20 -Gas Turbines, and Turbine Test Cells & Stands 48 -Landfill and/or Digester Gas Flares ELECTRONICS 29 -Automated Soldering 42 -Electronic Component Mfg FOOD 12 -Fish Canneries 12 -Smoke Houses 50 -Coffee Roasters 35 -Bulk Flour & Powered Sugar Storage SOLVENT USE 28 -Vapor & Cold Degreasing 30 -Solvent & Extract Driers 31 -Dry Cleaning ROCK AND MINERAL 04 -Hot Asphalt Batch Plants 05 -Rock Drills 06 -Screening Operations 07 -Sand Rock & Aggregate Plants 08 -Concrete Batch, CTB, Concrete Mixers, Mixers &Silos 10-Brick Manufacturing OTHER 01 -Abrasive Blasting Equipment 03 -Asphalt Roofing Kettles & Tankers 46 -Reverse Osmosis Membrane Mfg 51 -Aqueous Waste Neutralization 11 -Tire Buffers 17 -Brake Debonders 23 -Bulk Grain & Dry Chemical Transfer & Storage 45 -Rubber Mixers 21 -Waste Disposal & Reclamation Units 36 -Grinding Booths & Rooms 40 -Asphalt Pavement Heaters 43 -Ceramic Slip Casting 41 -Perlite Processing 40 -Cooling Towers -Registration Only 91 -Fumigation Operations 56 -WNTP (1 million gal/day or larger) & Pump Station NOTE: OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITTING AIR CONTAMINANTS MAY REQUIRE AN AIR POLLUTION CONTROL DISTRICT PERMIT. IF THERE ARE ANY QUESTIONS, CONTACT THE AIR POLLUTION CONTROL DISTRICT AT (858) 586-2600. HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division "' {city of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. Unless none of the requirements apply, the completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy- related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances . ...i If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. ...i Details on CAP ordinance requirements are available on the city's website. Project Name/Building Permit No.: Property Address/APN: Applicant Name/Co.: Applicant Address: Contact Phone: Contact information of person completing this checklist (if different than above): Name: Company name/address: Contact Phone: Contact Email: Applicant Signature: --'/ft:,,,,,O::'--;:__a __________ Date: -1 /-zzl I '-1 B-50 Page 1 of3 Revised 04/19 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For residential alterations and additions to existing buildings, contact the building counter for the building permit valuation. Building Permit Valuation (BPV) $ _,_]-=l-_3,..<--+.q-'--"'O_'Lc.._ _____ _ I D Residential □ New construction 1A □ Alterations: □ exempt □ BPV 2: $60,000 □ Electrical service panel upgrade 1A 1A 1-2 family dwellings and townhouses with attached garages only □ BPV 2: $200,000 1A Multi-family dwellings only where interior finishes are removed and significant site wcrk and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed D Nonresidential □ New construction 1B and 2 □ Alterations 2 1. Electric Vehicle Charging A. D Residential New construction and major alterations (or electric panel upgrade)* Please refer to Carlsbad Ordinance CS-349 when completing this section. □ One and two-family residential dwelling or townhouse with attached garage: □ One EVSE ready parking space required □ Exception : -□ Multi family residential· D Exception · Total Parking Spaces EVSESoaces Proposed Caoable Readv Installed Calculations: Total EVSE spaces= .10 xTotal parking (rounded up to nearest whole number) EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces -EVSE Installed (EVSE other may be "Capable," "Ready'' or "Installed.") Total *Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation~ $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation ~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. B D Nonresidential new construction (includes hotels/motels) □ Exception · Total Parking Spaces EVSE Soaces Proposed Caoable I Readv Installed I Total I I Calculation· Refer to the table below· Total Number of Parkinn Snaces nrovided Number of ronuired EV Sruaces Number of ronuired EVSE Installed Soaces □ 0-9 1 1 □ 10-25 2 1 □ 26-50 4 2 □ 51-75 6 3 □ 76-100 9 5 □ 101-150 12 6 □ 151-200 17 9 □ 201 and over 10 oercent of total 50 ""rcent of Ronuired EV Spaces Updated 4/12/2019 2 ,, City of Carlsbad Climate Action Plan Consistency Checklist 2. 0 Transportation Demand Management (TOM) A. List each proposed nonresidential use and gross floor area (GFA) allocated to each use. B. Employee ADT/1,000 square feet is selected from the table below. Use GFA Employee ADT for first Employee ADT for each 1,000 S.F. subsequent 1,000 S.F. 1.1. 0 h-,; \ 26[,l.f '$< '1 Total If total employee ADT is greater than or equal to 110 employee ADT, a TDM plan is required. TDM plan required: Yes □ ~ Updated 4/12/2019 Employee ADT Estimation for Various Commercial Uses ADT for first 1,000 s.f. EmpADTI 1000 s.f.1 Office ( all), 20 Restaurant 11 Retail, 8 Industrial 4 Manufacturing 4 Warehousin 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 1C1"Edition 20 11 4.5 3.5 3 1 , For all office uses, use SAN DAG rate of 20 ADT/1,000 sf to calculate employee ADT 3 Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf-1,000 sf= 8,334 sf 3. 8,334 sf/ 1,000 x 4.5 + 8 = 46 Em lo ee ADT Total Employee ADT 17- . r+ 3