HomeMy WebLinkAbout1075 LIGHTHOUSE RD; ; CB042089; Permit10-12-2004 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: C 4,( City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No: CB042089 Building Inspection Request Line (760) 602-2725 1075 LIGHTHOUSE RD CBAD RESDNTL Sub Type: RAD Status: ISSUED 2145312100 Lot #: 0 Applied: 05/27/2004 $37,080.00 Construction Type: VN Entered By: RMA Reference #: Plan Approved: 10/12/2004 0 Structure Type: Issued: 10/12/2004 0 Bathrooms: 0 Inspect Area: DUPLACK RES-360 SF ADDITION Orig PC#: Plan Check#: Applicant: PRECISION RESTORATION STE J 7313 CARROLL RD 92121 858 693-7655 Owner: DUPLACK CURTIS L&DONNA L 1075 LIGHTHOUSE RD CARLSBAD CA 92009 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add] Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Red. Water Con. Fee $287.47 Meter Size $0.00 Add'I Red. Water Con. Fee $186.86 Meter Fee $0.00 SDCWA Fee $0.00 , CFD Payoff Fee $3.71 PFF $0.00. PFF (CFD Fund) $0.00 License Tax ,. $0.00 License Tax (CFD Fund) $0.00 Traffic Impact Fee $0.00 Traffic Impact (CFD Fund) $0.00 Sidewalk Fee $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.OQ MECHANICAL TOTAL $0.00 Housing Impact Fee $0.00 Housing InLieu Fee Housing Credit Fee $0.00 Master Drainage Fee $0.00 .'-'- Sewer Fee PdditionaI Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $27.00 $20.00 $24.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $549.04 Total Fees: $549.04 Total Payments To ance Due: $362.18 3029 10/12/04 0002 01 02 CGP 362-18 FINAL AFPFtAL Inspector: \f\'-. Date: 7't)_( Clearance: NOTICE: Please take NOTICE that approval of your project includes the "lmpsition' fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. FOR OFFICE USE PLAN CHECK NO CITY OFRtZBAD BUILDING DE?AF 1635 Faraday Ave., Carlsbad, CA 92008 M. units CONTACT PERS8k44J4fferent kom applicant) 'Name ' - \ Address - ..,) City State Zip Telephone # Fax APPL?CANT D Contractor 0 Agent fo-ntactor 0 OJner Agent for Owner / , Name ' —" 'ç AddresZ' ' -_....,) City State/Zip Telephone PROPERTY OWNER - Name Address City State/Zip Telephone # 5 CONTRACTOR COMPANY NAME (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged mption. Any violation of e tio 7031.5 by any applicant for a pe subjects the a plicant to a civil pe It o t more tha •ve hundred doIes.[S50O1). \ I Name Address City State/Zip Sit License License C City Business License # 5e Designer Name - Address City State/Zip Telephone - - State License # 6 WORKERS COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company _ Policy No. Expiration Date__________________ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) C] CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California, WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred '\housand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. IGNATURE DATE OWNER BUILDER DECLARATION I hby affirm that I am exempt from the Contractor's License Law for the following reason: 0 \ as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. Q44, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such wçk himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold with one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). C] I, as\wner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor'kLicense Law does not apply to an owner of property who builds or improves thereon, and Contracts for such projects with contractor(s) licensed pursuant to t\e Contractor's License Law). 0 I am exept under Section Business and Professions Code for this reason: I personally\lan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO I (have I have\çot) signed an application for a building permit for the proposed work. I have contract\d with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): I plan to provide rtions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone 'number / contractors licse number(: I will provide som f the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address / phone number / type of work): PROPERTY OWNER SIGNA'kIRE ___________________________________________________ DATE COMPLETE THIS SECTION FR NON RESIDENTIAL BUILDING PERMITS ONLY J Is the applicant or future bui(4g occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 255O5,\5533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building\ccuPant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed wikhin 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YE A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OFMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8. CciIISTRUCTI0N LEAE1ZY - I hereby affirm that there is a constructi'Q lending agency for the performance of the work for which this permit is issued (Sec. 3097(i( Civil Code). LENDER'S NAME \- LENDER'S ADDRESS__________________________________________________________ 9 APPLICANT CERTIFICATION I certify that I have read the application and ste that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit, of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such p ot commenced withi s from the date of such per r R1913 building or work authorized by such permit is suspended or abandoned at any time after the vkrk is co enced for a pen of 181 (Section 106.4.4 iforSjidflding Code). APPLICANT'S \JLxi.Jk4 (., DATE WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request : For: 08/12/2005 Permit# CB042089 Inspector Assignment: JM Title: DUPLACK RES-360 SF ADDITION Description: Type: RESDNTL Sub Type: RAD Phone: 8582125393 Job Address: 1075 LIGHTHOUSE RD Suite: Lot 0 Location: Inspector: APPLICANT PRECISION RESTORATION Owner: DUPLACK CURTIS L&DONNA L Remarks: Total Time: Requested By: RICK Entered By: CHRISTINE CD Description Act Comment 19 Final Structural 1I 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Associated PCRs/CVs Inspection History Date Description Act lnsp Comments 04/28/2005 18 Exterior Lath/Drywall AP JM 04/20/2005 17 Interior Lath/Drywall AP JM 04/20/2005 18 Exterior Lath/Drywall CO JM CAULK ALL PENETRATIONS 04/13/2005 16 Insulation AP JM 04/07/2005 84 Rough Combo AP PD 03/09/2005 14 Frame/Steel/Bolting/Welding NR JM 03/03/2005 83 Roof Sheathing/Ext Shear AP JM INTERIOR WALL OK TO SHEAR 03/01/2005 13 Shear Panels/HD's CO TP NOTICE ATTCH (NOTHING IS ATTACHED) 12/17/2004 11 Ftg/Foundation/Piers AP JM OK TO POUR 12/16/2004 11 Ftg/Foundation/Piers CO JM NO APPROVED PLANS ON SITE EsGil Corporation In Partnership with Government for Building Safety DATE: October 7, 2004 LI LICANT r 63 JURIS. JURISDICTION: Carlsbad AN REVIEWER LI FILE PLAN CHECK NO.: 04-2089 SET: III PROJECT ADDRESS: 1075 Lighthouse Rd. PROJECT NAME: SFD Add. for Curtis & Donna Duplack The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. Lii The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. F-1 The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. LI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person LII REMARKS: By: Sergio Azuela Enclosures: Esgil Corporation 0 GA [1 MB [1 EJ Li PC 9/30 trnsmtLdot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In Partnersfiip with çovernmentfor(Bui14Thg Safety DATE: September 27, 2004 U APPLICANT U JURIS. JURISDICTION: Carlsbad REVIEWER U FILE PLAN CHECK NO.: 04-2089 SET: II PROJECT ADDRESS: 1075 Lighthouse Rd. PROJECT NAME: SFD Add. for Curtis & Donna Duplack j The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. E] The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. EJ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Donna Duplack 1075 Lighthouse Rd., Carlsbad, CA 92009 LI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person ptac)e51: Donna Duplack6) Telephone #: (760) 431-0572 Date '?/6(by: I1?i Fax #: MaiIeIephone- Fax In Person LI REMARKS: By: Sergio Azuela Enclosures: Esgil Corporation 171 GA LI MB LI EJ LI PC 9/20 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 04-2089 September 27, 2004 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 1075 Lighthouse Rd. DATE PLAN RECEIVED BY ESGIL CORPORATION: 9/20 REVIEWED BY: Serio Azuela PLAN CHECK NO.: 04-2089 SET: II DATE RECHECK COMPLETED: September 27, 2004 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? UYes GINo macvalue.doc Carlsbad 04-2089 September 27, 2004 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 6. Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1203.3. a) Clearly show on plans for all existing rooms and areas adjacent to the proposed addition: Family/Kitchen and Living/Entry. Additional corrections may follow. 7.. Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms and water closet compartments, 1/20 of area is required and minimum is 1.5 sq. ft. Section 1203.3. a) Clearly show on plans for all existing rooms and areas adjacent to the proposed addition: Family/Kitchen and Living/Entry. Additional corrections may follow. 8. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 (see exceptions): a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors. Sliding glass door. Please clearly show it on plans plan. 31. Specify on the plans the following information for the fireplace(s), per Section 106.3.3: a) Clearly show the clear distance to combustible materials, (2") between the fireplace walls and the new roof framing. The required information was not shown on plans. Provide framing details clearly showing the required 2" clearance between the (E) fireplace and the framing combustible materials. Carlsbad 04-2089 September 27, 2004 36. The regulations require a properly completed and properly signed Form CF-1 R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. The complete form CF-I R shall be imprinted on the plans and the required signatures shall be provided. 37. All energy items shown on the plans must be in agreement with the information shown on the properly completed Form CF-IR. Since the energy calculations are including the entire house; all windows, etc. for the entire house shall be clearly shown on plans. ALL STRUCTURAL PLANS AND SPECIFICATIONS SHALL BE SEALED AND SIGNED BY THE ENGINEER. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. - EsGil Corporation In Partnership with Government for (Building Safety DATE: June 10, 2004 U PLICANT U JURIS. JURISDICTION: Carlsbad U PLAN REVIEWER U FILE PLAN CHECK NO.: 04-2089 SET: I PROJECT ADDRESS: 1075 Lighthouse Rd. PROJECT NAME: SFD Add. for Curtis & Donna Duplack Li The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. Li The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. Li The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. Li The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Donna Duplack 1075 Lighthouse Rd., Carlsbad, CA 92009 Li Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Donna Duplack Telephone #: (760) 481-0572 Date contacted: ('trl(o'l (by: 30 ) Fax M. Mail %,/Telephone Fax In Person Li REMARKS: By: Sergio Azuela Enclosures: Esgil Corporation LI GA LI MB LI EJ LI PC 6/1 tmsmU.dot 9.320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 04-2089 June 10, 2004 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 1075 Lighthouse Rd. DATE PLAN RECEIVED BY ESGIL CORPORATION: 6/1 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: 04-2089 DATE REVIEW COMPLETED: June 10, 2004 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. .1 Please make all corrections on the originals and submit two new complete setsof.prints to: ESGIL CORPORATION. To facilitate rechecking, please. identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes 0 No Carlsbad 04-2089 June 10, 2004 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or altered. Draw the plans to scale and indicate the scale on the plan. Section 106.3.3. a) Dimensions shown on the Floor Plan provided are unreadable. Also dimensions for the adjacent areas to the proposed addition shall be included. 3. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 4. ShOw locations- of permanently wired smoke detectors with battery backup: Inside each bedroom. Centrally located in corridor or area giving access to sleeping rooms. On each story. When sleeping rooms are upstairs, at the upper level in close proximity to the stair. In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. NOTE: Detectors shall sound an alarm audible in all sleeping areas of the unit. Section 310.9.1. 5. When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided per the above, except that smoke detectors added at existing construction need only be battery powered. Section 310.9.1.2. Carlsbad 04-2089 June 10, 2004 Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1203.3. a) Clearly show on plans for the new proposed Entertainment room addition (window 1, which is a sliding glass door of 6X8, was not indicated on the South Side at the Floor Plan), and also clearly show it on plans for all existing rooms and areas adjacent to the proposed addition: Family/Kitchen and Living/Entry. Additional corrections may follow. Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms and water closet compartments, 1/20 of area is required and minimum is 1.5 sq. ft. Section 1203.3. a) Clearly show on plans for the new proposed Entertainment room addition (window 1, which is a sliding glass door of 6X8, was not indicated on the South Side at the Floor Plan), and also clearly show it on plans for all existing rooms and areas adjacent to the proposed addition: Family/Kitchen and Living/Entry. Additional corrections may follow. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 (see exceptions): a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors. Sliding glass door. Show the required ventilation for attics (or enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters). The minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 506/6 of the required vent is at least 3 feet above eave vents or cornice vents). Show area required and area provided. Section 1505.3. Where eave vents are installed, insulation shall not block the free flow of air. A minimum of 1" of air space shall be provided between the insulation and the roof sheathing. To accommodate the thickness of insulation plus the required 1" cl earance, member sizes may have to be increased for rafter-ceiling joists. Section 1505.3. Note on the plans: "Attic ventilation openings shall be covered with corrosion-resistant metal mesh with mesh openings of 1/4-inch in dimension." Section 1505.3. Provide a complete foundation plan. Additional corrections may follow. Note on plans that wood shall be 6" minimum above finish grade. Section 1806.1. Note on plans that surface water will drain away from building and show drainage pattern. Section 1804.7. Carlsbad 04-2089 June 10, 2004 Dimension foundations per U.B.C. Table 18-1-C- Floors Footing Supported* Thickness Width Depth Stemwall 1 6" 12" 12" 6" *Foundations may support a roof in addition to the floors. Where only a roof is supported, use foundation for one floor. Show foundation bolt size and. spacing. Foundation bolt size and spacing for shear walls must be clearly shown on the foundation plan. Section 1806.6. The following anchor bolt requirements shall apply in Seismic Zones 3 and 4, per Section 1806.6.1: a) Plate washers (minimum size of 2" x 2" x 3/16") shall be used on each anchor bolt. Show size, embedment and location of hold down anchors on foundation plan. Section 106.3.3. Note on plan that hold down anchors must be tied in place prior to foundation inspection. Section 108.5.2. City to place their soils notice on the plans. Show double top plate with minimum 48" lap splice. Section 2320.11.2. 22 Show nailing will be in compliance with Table 23-I1-B-I Clearly show the size and spacing of the ceiling joists on the plans. Specify all header sizes for openings over 4' wide. Section 2320.11.6. The minimum length of all shear walls shall be specified at each location on the structural plans. Detail shear transfer connections, including roof and floor diaphragms, to shear walls. Section 2315. a) Also provide cross-reference from details to plans. Ridges, hips, and valleys shall be at least one size larger than supported rafters. Section 2320.12.3. a) Show on plans the size of the Hip Beam at the roof framing plan. For Conventional Light-Frame Construction, buildings shall be provided with exterior and interior braced wall lines. Spacing shall not exceed 34' (25' for Seismic Zone 4 or for wind speeds >80 mph) on center in both directions in each story. Sections 2320.4.2 and 2320.5.1 and Table 23-IV-C-1. Carlsbad 04-2089 June 10, 2004 29. Show the following on the plans for the required braced wall panels. If the requirements of braced wall panels in conventional light frame construction are not possible, provide design calculations from a licensed Engineer or Architect. a) Show on the plans the location, length and type of braced wall panel as per UBC Section 2320.11.3 and Table 23-IV-C-1. Braced wall panels shall start at not more than 8' from each end of a braced wall line. Braced wall lines shall be in line or offset from each other by not more than 4 feet. In all Seismic Zones, braced wall panels in one story structures (or the top story of a two or three story building) shall be installed at each end and not more than 25' on center along the length of the braced wall line. b) Interior braced wall panels shall extend to the roof or floor diaphragm level. c) Any braced wall panel required by Section 2320.11.3 may be replaced by an alternate braced wall panel. UBC Section 2320.11.4. For alternate braced wall panels in one story buildings, show compliance with the following on the plans: i) Minimum braced panel length is 2'-8" in width and a maximum height of 101-011. ii) Each braced wall panel is sheathed on at least one face with 3/8" plywood sheathing nailed with 8d common or galvanized box nails per 23-I1-B-I and blocked at all plywood edges. iii) A minimum of two anchor bolts installed in accordance with SectionI806.6 between hold down devices. An approved hold down device fastened to the foundation and capable of providing an uplift capacity of not less than 1,800 pounds is provided at each panel end. • The foundation that supports the braced panels is continuous across the entire length of the braced wall line and reinforced with a minimum of one # 4 bar top and bottom. d) Continuous footings shall be provided under interior braced wall lines. See Section 2320.5.6 for possible exceptions. 30. Show the location, type and size (BTU's) of all heating and cooling appliances or systems. 31. Specify on the plans the following information for the fireplace(s), per Section 106.3.3: a) Clearly show the clear distance to combustible materials, (2") between the fireplace walls and the new roof framing. 32. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. 33. Note on the plans that receptacle outlet locations will comply with NEC Art. 210-52(a). 34. Provide plans, calculations and worksheets to show compliance with current energy standards. Carlsbad 04-2089 June 10, 2004 The requirements for the prescriptive package components have been updated as of June 1, 2001. If using the prescriptive compliance approach, show compliance with the new Package C or D, or the alternate component package for C or D (Packages A and B have both been eliminated). The regulations require a properly completed and properly signed Form CF-1 R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. All energy items shown on the plans must be in agreement with the information shown on the properly completed Form CF-IR. Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Measures Checklist". Show the make, model, type and efficiency of the space heating (or cooling) system. Note on the plans: "The manufactured windows shall have a label attached certified by the National Fenestration Rating Council (NFRC) and showing compliance with the energy calculations." On the proposed East Elevation shown on sheet.A-2 of the plans, the designer provided a note for the second floor window on the left hand side that reads: "MOVE AND RESIZE 2ND LEVEL WINDOW". Please clarify the exact meaning of this note and include -the- following information: .•. .......... . . . •.. . '.Full dimensioned floor plan of the room or rooms where the windows in question are located. . . : Size and type of the windows proposed. Include these windows, within the energy calculations. Additional corrections may follow. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. Carlsbad 04-2089 June 10, 2004 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 04-2089 PREPARED BY: Sergio Azuela DATE: June 10, 2004 BUILDING ADDRESS: 1075 Lighthouse Rd. SFD Add./ Curtis & Donna Duplack BUILDING OCCUPANCY: R-3 & U-i TYPE OF CONSTRUCTION: V-N BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Dwelling Add. 372 98.00 36,456 Air Conditioning" 372 3.60 Fire Sprinklers TOTAL VALUE: : .37,795 Jurisdiction Code 1cb IBy Ordinance 1994 UBC Building Permit Fee 1994 UBC Plan Check Fee Type of Review: EI Complete Review Structural Only LI Repetitive Fee [1 Other Repeats Hourly Hour * Esgil Plan Review Fee I $287.471 I $186.861 I $160.981 Comments: Sheet 1 of 1 macvalue.doc S BUILDING PLANCHECK CHECKLIST DATE: PLANCHECK NO.: CB '? BUILDING AEDESS: /0 75 WIA&YLV fQ PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER: ,4 /(/- EST. VALUE: ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. A Right-of-Way permit is required prior to construction of the following improvements: Please see the attached report of deficiencies marked with 0. Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: Date: By: Date: By: Date: ENGINEERING TI-IORIZ, By: FOR OFFICIAL USE ONLY JION TO ISSUE BUILDING PERMIT: - - - Date. _/ L Ic ENGINEERING DEPT. CONTACT PERSON Name: JOANNE JUCHNIEWICZ Dedication Checklist Improvement Application Improvement Checklist Future Improvement Agreement Grading Permit Application Grading Submittal Checklist Right-of-Way Permit Application Right-of-Way Permit Submittal Checklist and Information Sheet Sewer Fee Information Sheet City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: (760) 602-2775 CFD INFORMATION Parcel Map No: Lots: Recordation: Carlsbad Tract: A-4 H:\WORD\DOCSCHKLSVBuding Ptancfledc Cklst Form (Generic).doc 1 Rev. 7/14/00 BUILDING PLANCHECK CHECKLIST SITE PLAN (3112 —b J PwC3 'k £4 1ST 2ND U 3RD U 1. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow F. Right-of-Way Width & Adjacent Streets B. Existing & Proposed Structures G. Driveway widths C. Existing Street Improvements H. Existing or proposed sewer lateral D. Property Lines I. Existing or proposed water service E. Easements J. Existing or proposed irrigation service 2. Show on site plan: A. Drainage Patterns Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. U 3. Include on title sheet: Site address Assessor's Parcel Number Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION H:W0RDDOCSCMKLSflBw1ding Plandweck Cktst Form (Geneiic).doc 2 Rev. 7114100 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3rd DISCRETIONARY APPROVAL COMPLIANCE U 4a. Project does not comply with the following Engineering Conditions of approval for ProjectNo._______________________________________________ U U U 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS fl fl 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $15.000, pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 h/2fl x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS U U U 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $75,000, pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the H:WORD\DOCS\CHKLSTWUdiflg plancfleck Cklst Form (RIDDLE- HARVEY 1-12-00).doc 3 Rev. 12/28f96 FE BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: Date: fl 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $310 so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: 0 6c. Enclosed please find your Future Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Future Improvement Agreement completed by: Date: 0 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11 .06.030 of the Municipal Code. . UI 0 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). 0 0 0 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: El 0 0 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) H:\WORD\DOCS\CHKLS1\BUiIdifl9 Plancheck Cklst Fern, (Generic 7-14-00).doc 4 Rev. 7/14/00 BUILDING PLANCHECK CHECKLIST 3RD E2" U U 7d .No Grading Permit required. U U U 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or fV private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: U U 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: Date: U U 10. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by J the City Engineer prior to issuance of grading or building permit, whichever occurs first. U U 11. red fees are attached No fees required WATER METER REVIEW U U .12a. Domestic (potable) Use j¼J ' Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. All single family dwelling units received "standard" 1" service with 5/8" service. H:\WORD\DOCSCHKLSTBuflding Plancheck Cklst Form (Generlc).doc 5 Rev. 1/14100 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. Maximum service and meter size is a 2" service wIth a 2" meter. If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand. (manifolds are considered on case by case basis to limit multiple trenching into the street). 12b. Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: _i ..-.. STA 1+00 Install 2" service and 1.5: meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (wl a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: Hydraulic grade line Elevation at point of connection (POC) Pressure at POC in pounds per square inch (PSI) Worse case zone (largest, farthest away from valve Total Sprinkler heads listed (with gpm use per head) Include a 10% residual pressure at point of connection 3. In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water H:W0RD\D0CS\CI1KLSrBu5ding Plantheck CId$t Form (Genenc).doc 6 Rev. 7/14/00 BUILDING PLANCHECK CHECKLIST 1S1 2ND 3RD service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. I D 12c. Irrigation Use (where recycled water is available) Recycled water meters are sized the same as the irrigation meter above. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. 13. Additional Comments: I H:WORD\DOCS\CHKLSflSuiJding Plancfled, Mist Form (GeneiiC).doC Rev. 7/14/00 . . -6 0 C) .c . o o 0 C C' C M c f El r PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB t/ fte 10 6 I Address 116J7fr/o)IE j€t: Planner tfl IkLE $70OW6 Phone(760)602- L1t'P2.6 APN: Type of Project & Use: Net Project Density:_______________________ Zoning: ' General Plan: /Z /'V Facilities Management Zone: CFD (in/out) #_Date of participation: Remaining net dev acres:______ (For non-residential development: Type of land used created by this Circle One permit: ) Legend: Z Item Complete . Q Item Incomplete - Needs your action Environmental Review Required YES ____ NO ____ TYPE DATE OF COMPLETION: - Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES NO TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YEISX NO____ CA Coastal Commission Authority? YES__ N'?< If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or xemp Coastal Permit Determination Form already comp d? YES____ NO____ If NO,completè Coastal Permit Determination Form now. Coastal Permit Determination Log #: . '. . . , Follow-Up Actions: StampBUilding Plans as "Exempr' or "Coastal Pernit Requited" (at minimum FloorPlans). Complete Coastal Permit Determination Log as needed. Inclusionary Housing Fee required: YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenahce, enter CB#, toolbar; Screens, Housing' Fees, Consfruct Housing Y/N, Enter Fee, UPDATE!) Site Plan: H:'ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 El U 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). U U 2. Provide legal description of property and assessor's parcel number. Policy 44 - Neighborhood Architectural Design Guidelines 1. Applicability: YES NO K U U U 2. Project complies YES NO________ Zoning: U 0 1. Setbacks: Front: Required Shown Interior Side: Required 5 Shown /9 Street Side: Required 1 0 Shown I C) Rear: Required { ' Shown _________ Top of slope: Required - Shown I'U 0 2. X Fro: tructure setbacks: Required Shown : Required Shown Required Shown Required Shown paration: Required Shown 'U U 3. Lot Coverage: Required Y'0 ( Shown 51 U 0 4. Height: Required 30 Shown 1(0 5.' Parking: Spaces Required Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments ii S/i4 A 2-) e/efra+ erLs 3(p /, IiOW_~ aayaqe11nhc(Ohc-1 /2<f I, Verj rips (I-LC' Sh-/I a t-io Car ea-rati-ic, V V a4epa7'7/Jnc prbv'dir1j ctii addt-ho-P7 le x.5 lliah +Iiree aun amdØ'ô&v/thti.r' rf/'Oor LIJ-ea 15 qviremeri OK.TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE____ —07 _____ H:ADMIN\COUNTER\BdgPnchkRevChkIst Rev 9/01 CB042089 1075 LIGHTHOUSE RD CBAD DUPLACK RES-360 SF ADDITION RESDNTL RAD Lot#: PRECISION RESTORATION 4, L4i/o1 - < Ito /ô C L1 77- -J-- /-;~ - ay" iôli1 P~w