HomeMy WebLinkAbout1075 PALM AVE; ; CB141440; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
07-23-2014 Cogeneration Permit Permit No:CB141440
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
Applicant:
1075 PALM AV CBAD
COGEN
2051910500
$6,400.00
Sub Type: PHOTO
Lot#: 0
Constuction Type: 5B
Reference #:
EDSON TRUST: 16 ROOF MOUNT PV
Owner:
Status: ISSUED
Applied: 06/23/2014
Entered By: JMA
Plan Approved: 07/23/2014
Issued: 07/23/2014
Inspect Area:
Plan Check#:
MARINER MECHANICAL INC OBA ADROIT SOLAR
STE 32
EDSON LEGACY TRUST 10-09-12
1135 GARRET AV
SAN DIEGO CA 92109
858-483-3568
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Green Bldg Stands (SB1473) Fee
$97.47
$0.00
$68.23
$81.77
$0.00
$1.00
$1.00
1075 PALM AVE
CARLSBAD CA 92008
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Additional Fees
TOTAL PERMIT FEES
Total Fees: $249.47 Total Payments To Date: $249.47 Balance Due:
Inspector: Clearance:
$0.00
$0.00
$0.00
$0.00
$249.47
$0.00
NOTICE: Please take NOTICE that approval of your project includes the 'Im osition of fees, dedications, reseivations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES lT APPLY to any
fe xacti n f which ou hav v· I n iven N TICE similar to thi or as t whi h a t of limitati ns has revi I h r,,vi ex ire .
THE FOLLOWING APPROV~LS REQU,IRED PRIOR TO PERMIT ISSUANCE: □PLANNING □ENGINEERING
~ ~ . <(•'f·
~ CITY Of
CARLSBAD
JOB ADDRESS
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
Ph: 760-602-2719 Fax: 760-602-8558
email: building@carlsbadca.gov
www.carlsbadca.gov
SUITEt/SPACEI/UNIT#
□BUILDING □FIRE
Plan Check No.
Est. Value
Plan Ck. Deposit
Date ~
APN
CT/PROJECT# # BEDROOMS # BATHROOMS TENANT BUSINESS NAME
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
3 · 1.,,,'-{ /('-t.l ~-f h t-J
PATIOS (SF) DECKS (SF) FIREPLACE
YES0,
PROPERTY OWNER
ADDRESS
CITY (0'1
CITY
PHONE
EMAIL
ADDRESS
CITY STATE ZIP
PHONE FAX
EMAIL
STATE UC.#
0HAZMAT/APCD
0
SWPPP
CONSTR. TYPE OCC. GROUP
FIRE SPRINKLERS
YES0NO□
(Sec, 7031.5 Business and Professions Code: Any City or County which requires a permit to. construct. alter, im rove, demolish or repair any structure, prior to its issuance, also requires the applicant for such per_m1t to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law /Chapter 9, commending with Section 7000 of Division 3 of the B_usiness and Professions Code) or that he 1s exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a
civil penalty of not more than five hundred dollars {$500)).
W 0 R KER S' C 0 MP ENS A_T 10 N ,
Workers' Compensation Declaration: I hereby affirm under penalty of petjury one of the following declarations: D I h~nd will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performar.ce of the work for which this permit is issued.
uJ-r'(ave and will maintain worker ' ompen_!a n, a! reQUI by S¥on 3700 e Labor Code, for the performance f e work for which this permit 1s issued. My workers' compensatio~ insurance earner and polic
number are: Insurance Co. f\/ ) ~ ~ olicy No. __::7-li,~q_.1.,'--'µLJ!_JLI.I.J--Expiration Date~· iL-IL:-=-~..-!~'--:1---
Jl!i§.section need not be completed if e permit Is f r one hundred dollars ($100) or less. LJ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, ! shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compe tion cov e Is unlawful, a d shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In
addition to the cost of compensation, damages as prov d or· S tlo 3706 of the e, interest and attorney's fees,
LS CONTRACTOR SIGNATURE
I hereby affirm that I am exempt from Contractor's Ucense Law fort
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec, 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □
□
□
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License law).
I am exempt under Section _____ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. OYes ONo
2. I (have/ have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide lt1e proposed construction (include name address I phone/ contractors' license number):
4. I plan to provide portions of the work, but I ha ired the following person to coordinate, supervise and provide the major work (include name /address/ phone/ contractors' license number):
r , but I tr ed (hired) the followi persons to pro~ide the work indicated (include name/ address/ phone I type of work):
-
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? Yes No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air Quality management district? Yes No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT,
I certify that I have read the appllcatlon and state that the aboYe lnfonnatlon is correct and that the lnfonnatlon on the plans Is accurate. I agree to comptywlth all City ordinances and St.ate laws relating 1D building construction.
I hereby authorize representative of the City of Carlsbad to enter UJXln the above menUoned property for inspection purp:ises. I ALSO AGREE TO SAVE, INDEMNIFY .AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST All LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA M OSHA pem,~ is required for excavations over 5'0' deep and demolition oro:instruction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Buik:ling Official under the provisions of this Code shal xpire by Umitation and berome null and void ff the buik:ling orVl()rk authorized by sud1 pemiil is not oommenced 'Mthin
180 days from the date of such permit or if the buik:lin or'Mlrk auth · y sud1 pemiit is sus nded or abandoned at any time after the WJrk is commenced for a period of 180 days (Section 100.4.4 Unifomi Building Code).
fl5 APPLICANT'S SIGNATURE DATE tO
STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
Fax (760) 602-8560, Email building@carlsbadca.gov or Malt the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
CO#: (Office Use Only)
CONTACT NAME OCCUPANT NAME
ADDRESS BUILDING ADDRESS
CITY STATE ZIP CITY STATE
Carlsbad CA
PHONE FAX
EMAIL OCCUPANT'S BUS. LIC. No.
DELIVERY OPTIONS
PICK UP: CONTACT (Listed above) OCCUPANT (Listed above)
CONTRACTOR (On Pg. 1)
MAIL TO: CONTACT (Listed above)
CONTRACTOR (On Pg. 1)
OCCUPANT (Listed above)
MAIL/ FAX TO OTHER: _______________ _
.15 APPLICANT'S SIGNATURE
ASSOCIATED CB#------------
NO CHANGE IN USE/ NO CONSTRUCTION
CHANGE OF USE/ NO CONSTRUCTION
DATE
ZIP
Inspection List
Pennit#: CB141440 Type: COGEN PHOTO EDSON TRUST: 16 ROOF MOUNT PV
Date Inspection Item Inspector Act Comments
09/30/2014 35 Photo Voltaic (PV) RI
09/30/2014 35 Photo Voltaic (PV) SP AP
09/30/2014 39 Final Electrical RI
09/30/2014 39 Final Electrical SP Fl
Wednesday, October 01, 2014 Page 1 of 1
DATE: 07/21/2014
JURISDICTION: Carlsbad
PLAN CHECK NO.: 14-1440
EsGil Corporation
In 'l'artnersnip witn government for (}3uiUino Safety
SET: II revised
PROJECT ADDRESS: 1075 Palm Ave.
PROJECT NAME: Cobb 3,000 watt rooftop PV system
□ APPLICANT
□ JURIS.
□ PLAN REVIEWER
□ FILE
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ EsGil Corporation staff did not advise the applicant that the plan check has been completed.
D EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted: (by:
Telephone#:
) Email:
Mail Telephone Fax In Person
0 REMARKS:
By: Morteza Beheshti
EsGil Corporation
D GA D EJ D MB D PC
Enclosures:
7/21 walkin
Fax#:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: 07/18/2014
JURISDICTION: Carlsbad
PLAN CHECK NO.: 14-1440
EsGil Corporation
In (Partnersfiip witfi (jovernmentfor<Bui{aing Safety
SETII
PROJECT ADDRESS: 1075 Palm Ave.
PROJECT NAME: Cobb 3,000 watt rooftop PV system
□ APPLICANT
fl JURIS
□ PLAN REVIEWER
□ FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
D EsGil Corporation staff did not advise the applicant that the plan check has been completed.
~ EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Rick Trept Telephone#: 619.992.6337
~ate contacted:9-/ (<() (by:V'At Email: rickt@adroitsolar.com Fax #:
t;,,'lail Telephone Fax In Person
0 REMARKS:
By: Morteza Beheshti
EsGil Corporation
0 GA O EJ O MB O PC
Enclosures:
7/11
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad 14-1440
07/18/2014
GENERAL PLAN CORRECTION LIST
JURISDICTION: Carlsbad
PROJECT ADDRESS: 1075 Palm Ave.
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 7/11
REVIEWED BY: Morteza Beheshti
FOREWORD (PLEASE READ):
PLAN CHECK NO.: 14-1440
DATE REVIEW COMPLETED:
07/18/2014
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and disabled access. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. The approval of
the plans does not permit the violation of any state, county or city law.
• Please make all corrections and submit two new complete sets of prints to:
ESGIL CORPORATION.
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
□ Yes □ No
Carlsbad 14-1440
07/18/2014
ELECTRICAL and ENERGY COMMENTS
PLAN REVIEWER: Morteza Beheshti
ELECTRICAL (2013 CALIFORNIA ELECTRICAL CODE)
1. Please provide a AC disconnect within sight of the inverter. CEC 690.14(0)(2) THE
DISCONNECT IS NOT INCLUDED ON SINGLE LINE.
2. Please indicate the inverter output conduit and wiring designations missing on single line.
ROMEX SHOWN, PLS. CLARIFY ROUTING FOR PHYSICAL PROTECTION AND
CODE COMPLIANCE.
3. Provide the required separate ground electrode for the "photovoltaic rack assembly" per
690.47 (0) or connect to the building electrode system. If the electrode conductor is
routed through electrical equipment (disconnects, panels, meter enclosures, etc) then
provide a detail on the plans describing compliance with CEC 250.64(C). (Conductor
splices only allowed with compression connectors or exothermic welding.) Size the
ground electrode conductor per 250.166, not smaller than #8. STILL #10 IS SHOWN.
*Note: The rack electrode system is described in the 2010 CEC 690.47(0) and the
upcoming 2016 CEC 690.47(0). It was mistakenly deleted from the 2013 CEC.
Note: If you have any questions regarding this Electrical and Energy plan review list please
contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this
list (or a copy) where the corrected items have been addressed on the plans.
DATE: 07/07/2014
JURISDICTION: Carlsbad
PLAN CHECK NO.: 14-1440
EsGil Corporation
In Partnership with government for IBuiUing Safety
SET: I
PROJECT ADDRESS: 1075 Palm Ave.
PROJECT NAME: Cobb 3,000 watt rooftop PV system
~_)PPLICANT
~:URIS
□ PLAN REVIEWER
□ FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
D EsGil Corporation staff did not advise the applicant that the plan check has been completed.
~ EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Rick Trept Telephone#: 619.992.6337
/-Date contacted: -11 t (b~ Email: rickt@adroitsolar.com Fax #:
-i:::; Mail T~~one Fax In Person
0 REMARK~ '1°"'-J
By: Morteza Beheshti
EsGil Corporation
0 GA O EJ O MB O PC
Enclosures:
6/26
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad 14-1440
07/07/2014
GENERAL PLAN CORRECTION LIST
JURISDICTION: Carlsbad
PROJECT ADDRESS: 1075 Palm Ave.
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 6/26
REVIEWED BY: Morteza Beheshti
FOREWORD (PLEASE READ):
PLAN CHECK NO.: 14-1440
DATE REVIEW COMPLETED:
07/07/2014
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and disabled access. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. The approval of
the plans does not permit the violation of any state, county or city law.
• Please make all corrections and submit two new complete sets of prints to:
ESGIL CORPORATION.
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
□ Yes □ No
Carlsbad, 14-1440
07/07/2014
ELECTRICAL and ENERGY COMMENTS
PLAN REVIEWER: Morteza Beheshti
ELECTRICAL (2013 CALIFORNIA ELECTRICAL CODE)
1. Please provide a AC disconnect within sight of the inverter. CEC 690.14(0)(2)
2. Please indicate the inverter output conduit and wiring designations missing on single line.
3. Provide the required separate ground electrode for the "photovoltaic rack assembly" per
690.47 (0) or connect to the building electrode system. If the electrode conductor is
routed through electrical equipment (disconnects, panels, meter enclosures, etc) then
provide a detail on the plans describing compliance with CEC 250.64(C). (Conductor
splices only allowed with compression connectors or exothermic welding.) Size the
ground electrode conductor per 250.166, not smaller than #8.
*Note: The rack electrode system is described in the 2010 CEC 690.47(0) and the
upcoming 2016 CEC 690.47(0). It was mistakenly deleted from the 2013 CEC.
Note: If you have any questions regarding this Electrical and Energy plan review list please
contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this
list (or a copy) where the corrected items have been addressed on the plans.
Carlsbad.14-1440
07/07/2014
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Morteza Beheshti
BUILDING ADDRESS: 1075 Palm Ave.
BUILDING OCCUPANCY:
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
------
Bid . Permit Fee b Ordinance g y •
Type of Review: □ Complete Review
D Repetitive Fee ~;.7 Repeats
* Based on hourly rate
Comments: 1.5 hour plan review.
D Other
[J Hourly
EsGil Fee
PLAN CHECK NO.: 14-1440
DATE: 07/07/2014
TYPE OF CONSTRUCTION:
Reg. VALUE ($)
Mod.
$187.SOI
D Structural Only
1--___ 1_.~s1 Hrs. @ •
$100.00 _ $1so.001
Sheet 1 of 1
macvalue.doc +
«~;
~ CITY OF
CARLSBAD
PLANNING DIVISION
BUILDING PLAN CHECK
APPROVAL
P-29
DATE: 6/23/14 PROJECT NAME: SOLAR PANELS PROJECT ID:
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.er1rlsbadr:;umv
PLAN CHECK NO: CB141440 SET#: ADDRESS: 1075 PALM AV APN:
[8) This plan check review is complete and has been APPROVED by the PLANNING
Division.
By: GINA RUIZ
A Final Inspection by the PLANNING Division is required □ Yes [?g No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check APPROVAL has been sent to:
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING ENGINEERING FIRE PREVENTION
760-602-4610 760-602-2750 760-602-4665
□ Chris Sexton □ Kathleen Lawrence □ Greg Ryan
760-602-4624 76D-602-2741 760-602-4663
Chris.Sexton@carlsbadca.gov Kathleen.Lawrence@carl§badca.gov Gregoo:.R)'.an@carl§badca.gov
□ Gina Ruiz □ Linda Ontiveros □ Cindy Wong
760-602-4675 760-602-2773 76D-602-4662
(,ina.f!uiz@~arl§!ladc!!.gov Linda.Ontiveros@carlsbadca.gov C~nthia.Wong@c,!rl~bad~a.gov
□ □ □ Dominic Fieri
76D-602-4664
Domjnic.Eieri@carl§badca.gov
Remarks: