HomeMy WebLinkAbout1088 LAGUNA DR; ; CB901090; Permit (2)R BUILDING PERMIT Permit NO: CB901090 08/24/90 11:15 Project No: A9000220 Page 1 of 1 Development No: Job Address: 1088 LAGUNA DR - . Str: Fl: Ste: Permit Type: RESIDENTAL ADDITION/ALTERATION 765' 08/24/90 0001 0.1 02 Parcel No: 155-272-19-00 C-F'RMT 231.00 Valuation: 4,500 Construction Type: NEW Occupancy Group: I1A Class Code: Status: ISSUED Description: FIRE SEPARATION WORK/BLDG "A" Applied: 06/28/90 CHANGE OCCUPANCY FIRST FLOOR TO hA (CD) Apr/Issue: 08/24/90 Validated By: CD OWNER : VILLAS DE CARLSBAD Lic. OWNER *** Fees Required *** *.k.*-.Fees Collected & Credits - -----s: - Adjustments: J/00\? .\ ota ~C~red-its: .00 Total Fees: 2.78.0O'\ 'oaT'Payments: 47.00 / Balancè-.Due.: . 231.00 'description s Building Permit Plan Check ' ' - -- .' -•--. I ---- • - Strong Motion Fee Enter 'V to Autocal License Tax >J * BUILDING TOTAL Enter "Y" for Plumbing Isse..Fe,eA >• " Enter "Y" for Eledtric Istie Fee.>\.It, - Enter 'Y' for Mechanical Issue INS .'.,- '-.-- CLEARANCE 'PROVAt. DATE f jf - CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad CA 92009 (619) 438-1161 j 72.00 7.00 c 2 4 1.00 158.00 Y 278.00 PERMIT APPLICATION City of Carlsbad Building Department 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 1. PERMIT TYPE I A - 0 COMMERCIAL ONEW DTENANT IMPROVEMENT B - 0 INDUSTRIAL DNEW 0 TENANT IMPROVEMENT C - []RESIDENTIAL []APARTMENT C:] CONDO []SINGLE FAMILY DWELLING DADDITION/ALTERATION El DUPLEX []DEMOLITION DRELOCATION DMOBILE HOME []ELECTRICAL []PLUMBING DMECHANICAL []POOL DSPA []RETAINING WALL DSOLAR 0oTHE22. - IA(2I [ST. 1 PLAN CX DEPOSIT V <Z -7 VALID. BY DATE 6464 06/28/90 0OOi Ol i C-PRMT CPtt/37? - 47.00 E Building or Suite No. Nerest Cross St etOs LEGAL DESCRIPTION Lot No. Subdivision Name/Number Unit No. Phase No. CHECK BEL(YJ IF SUBMITTED: EJ2 Energy Calcs 02 Structural Calcs 02 Soils Report Di Addressed Envelope ASSESSORS PARCEL EXISTING USE Se'.r PROPOSED USr],', .. DESCRIPTION OF WORK -7-p4,q £,A)L I II ViT 4tI Wer 2t1 M#.I hevs d4 q r42, Wi- BLDG. SQ. FIG. - 1' N OF STORIES e64ciI4,r.S ,I CON TpçT PERSON .—' I' NAME /pJ Mh ADDRESS / 4vt.. t}e,o 724c/ CITY STATE ZIP CODE DAY TELEPHONE 3 Ito SIGNATURES APPLI C] CONTRACTOR 0 AGENT FOR CONTRACTOR DOWNER DAGENT FOR OWNER NAME ADDRESS CITY STATE ZIP CODE DAY TELEPHONE PROP , v; L.:4-tQ OWNER ADDRESS DLESSEE []TENANT CITY STATE ZIP CODE DAY TELEPHONE CONTRACTOR NAME ADDRESS CITY STATE ZIP CODE DAY TELEPHONE STATE LIC. N LICENSE CLASS CITY BUSINESS LIC. N SIGNATURE TITLE DATE DESIGNER NAME ADDRESS CITY STATE ZIP CODE DAY TELEPHONE STATE LIC. # WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm that I have a certificate of consent to self-insure issued by the Director of Industrial Relations, or a certificate of Workers' Compensation Insurance by an anitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POLICY NO. EXPIRATION DATE Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shalt not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE OWNER-BUILDER DECLARATION - Owner-Builder Declaration: I hereby affirm that I am exempt from the contractors License Law for the following reason: 0 I as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon,, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any Structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001). SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES E] NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYES FIND Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYES ONo IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES ARID THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 30970) Civil Code). LENDER'S NAME LENDER'S ADDRESS APPLICANT'S SIGNATURE I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended o&andoneAdat any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building code). DOWNER E] CONTRACTOR DBT PHONE DATE: WHITE: File YELLOW: Applicant PINK: Finance I CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB901090 FOR 10/10/90 INSPECTOR AREAPD DESCRIPTION: FIRE SEPARATION WORK/BLDG "A" PLANCK# CB901090 CHANGE OCCUPANCY FIRST FLOOR TO hA (CD) 0CC GRP TYPE: PAD CONSTR. TYPE NEW JOB ADDRESS: 1088 LAGUNA DR STR: FL: STE: APPLICANT: JACOBSEN, D. PHONE: 234-4316 CONTRACTOR: • PHONE: OWNER: VILLAS DE CARLSBAD PHONE: REMARKS: T1/NH/RUDY/259-6881 INSPECTO SPECIAL INSTRUCT: I TOTAL TIME: --RELATED PERMITS- PERMIT# TYPE STATUS CB900164 PAD ISSUED CD LVL DESCRIPTION ACT COMMENTS 19 ST. Final Structural A70 • INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 100290 Frame/Steel/Bolting/Welding AP PD 091990 Interior Lath/Drywall AP PD ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: JURISDICTION: PLAN CHECK NO: SET:11 PROJECT ADDRESS: to Lw PROJECT NAME: Sr op 0 C C . [JAPP CANT JURISDICTION L JPLAN C E flFILE COPY TUPS DESIGNER E The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. V The plans transmitted herewith will substantially comply J with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. E The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. r--i The check list transmitted herewith is for your information. L..J The plans are being held at Esgil Corp. until corrected plans are submitted for recheck; fl The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of 'the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone # REMARKS: Oiu &J CJT Lfl L1 Ujmj T1Y.Lu. ?&o cm M\ Si T14 \ U S \°jp L,mca. UJ Lt. ~J p1 p7S To QE,Ou.k -r'W S. k. -'çm OPso.. MI(. 1\4 SMt a By: %L-tA Enclosures: ESGIL CORPORATION '-'()•. GA 11 AA ill] vw 0 DM SM iiL L1,1Y2 ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619)560-1468 DATE: - 1tI\5O LThPPLICANT JURISDICTION: --M-FE-AN CHEC OFILE COPY PLAN CHECK NO: O1oo SET: m [J-UPS [TDESIGNER PROJECT ADDRESS: (p PROJECT NAME:C)i1t-r Tb n The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies Li identified on the enclosed check'lis't, and should be corrected and resubmitted for a cornolete recheck. 0 The check list transmitted herewith is for your information. "I The plans are beingheld at Esgil Corp. until corrected J J olans are submitted for recheck. - . n. D The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. ; The applicant's :copy of the check list has been sent to: M'.E6 OS \)fl-i,rr , (CD D Esgil staff did not advise the appli•cant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: rftijo0 Telephone 4SS 131- REMARKS <t4 r- 2 -. U 3 - vu ". 'JJ V L I 1.4 4 vii U I- -S -r 60Tr4t.4n No-r c -o -r_Ou9'Nc41 __S'.1b4 .tQ j-r By: ____ Enclosures: ESGIL CORPORATION El GA 11AA Dvw C] DM PLAN tK W. C 3 - C) 0 JURISDICTION: C nyz LS. 3 To: 3AYVI ¶2.c .i, . c0 'IAPL i &- Zoo 5g,j Dt.4o PROJECT ADDRESS: O (—i..0 ru r 12. oor -r1 OCCUPANCY: QEC. I USE: (LrZ)C 400i1 iorz ULrrDTZ1 TYPE OF CONSTRUCTION: IJ\?Q, j LCC) WI ACflIALAREA:To 4 ALLMABLR AREA: 1p ct.co - SWRIES: HElI: SPRINKLERS: L%iE\) O PLAN CORRECTION sH:r APARTMENTS: WITH HANDICAPPED AESSTh]1ITY Date initial plan check completed: By:___________________________ Applicant contact person: 0r'4 Ylc L_oT1 40 3;:%n'(ES Telephone: 0S 4-S I 45 FOREWORD: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1988 UBC (eff. 1/1/90) 1988 UPC (eff. 1/1/90) 1987 NEC (eff. 10/28/87) 1988 tJMC (eff. 1/1/90) The above regulations apply to residential construction, regardless of the code editions adopted by the ordinance. The items listed need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1988 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. Date plans received by jurisdiction: To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed i.e., plan sheet, specification, etc. Be Date plans received by Esgil Corporation: sure to enclose the marked up list when you submit 1\z\o the revised plans. NOTE: :DMETED List. No. 31: R-1 General, For, Apartment Projects With Handicapped Access, and Without Any Energy Tables or Supplement For Local Ordinance or Local Policy Requirements. (1988 1JBC) A. PLANS. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: 11. Esgil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, (619) 560-11 68. 2. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Specify on the Title Sheet of the plans the gross floor area of each element of this project _nGluding unitg, gaxag, carpst, 4at,.4aG1c and baleny. tion 302 (ii-)'. Provide a Building/Unit Schedule on the Title Sheet. Include the following: Designation and area of each dwelling unit type. Number of each designated unit types in each building (including handicapped access units). The jurisdiction's building department. Indicate on the Title Sheet of the plans, the I name of the legal owner and name of. person responsible for the preparation :of the plans. Section 302 (a) 7. (Z Provide a statement on the Title Sheet of the plans that this project shall comply with Title 7 24 and 1988 UBC, UNC, and UPC and 1987 NEC. 7. Provide the site address and a vicinity sketch on the Title Sheet. 6. All sheets of the plans and the first sheet of the calculations are required to be signed and sealed by the California licensed architect or engineer responsible for their preparation. (Calif. Business and Professions Code) / Indicate on the Title Sheet whether or not a grading permit is required for this project. Show on the Title Sheet all buildings, structures, pools, walls, etc. included under this application. Any portion of the project shown on the site plan that is not included with the building permit application filed should be clearly identified as "not included" on the site plan or Title Sheet. () Provide a Building Code Data legend on the 7 Title Sheet. Include the following code / information for each building proposed: (occupancy Group , Type of Construction_________________________ Sprinklers: Yes or No_____________________ ( Stories ( Height L Floor Area (Justification to exceed allowable area in Table 5-C. (if—ep$-ianb+e) Justification to exceed allowable height or stories in Table 5-D. (if applicable) C. List any other occupancies or uses included in each building, i.e., common laundry, cocoon storage, garage, rental office, etc. Provide a fully dimensioned site plan drawn to /I . scale. Show: north arrow, property lines, easements, streets, existing and proposed buildings and structures, location of yards used for allowable increases of building area and dimensioned setbacks. Provide a statement on the site plan stating: "All property lines, easements and buildings, both existing and proposed, are shown on this site plan". . Clearly designate on the site plan existing buildings to remain, existing buildings to be demolished, buildings to be constructed under this permit and any proposed future buildings. Show on the site plan all proposed walls, retaining walls and fences. Specify their heights on the plans. Clearly dimension building setbacks from property lines, street centerlines, and from all adjacent buildings and structures on the site plan. Dimension distance from curb to property line. )1. Show and dimension on the site plan all building projections including eaves, balconies, cornices and similar appendages extending beyond the exterior walls. ,34. Show the location of any designated flood plains, open space easements, or other development restricted areas on the site plan. 12/15/89 . . 2 C. BUILDING AREA 38 Provide on the Title Sheet of the plans the code justification for exceeding the basic allowable area in Table 5-C. Section 506. 39 When a building has more than one occupancy, the area shall be such that the sum of the ratios of the actual area divided by the allowable area for each occupancy shall not exceed one. Section 503. 4/. As shown, the building(s) is/are over area for I the type of construction shown. Table 5-C. 44. - No single story can exceed the basic area / allowed by Table 5-C plus theincreases allowed by Section 506. Unless considered a separate story, the floor area of a mezzanine shall be included in calculating the area of the story in which it is located. Section -505. A basement need not be included in the total allowable area, provided such •a basement does not qualify as a story nor exceed the area permitted for a one story building. Section 505-. D. AREA SEPARATION WALLS 4/ Area separation walls may separate portions of a building and allow each portion to be considered a separate building; however, the area separation wall must be four-hour in Type I, 11-P.R., III and IV buildings; and two-hour in Type II one-hour, Type II-N and Type V buildings. Section 505 (e) 1. 4/. Openings in four-area separation walls are required to be protected - with three-hour f ire- resistive assemblies; 1-1/2 hour fire- resistive assemblies are required to protect openings in 2 hour area separation walls. Section 505 (e). 4/. Openings in area separation walls are limited to twenty-five percent of the length of the wall in each story. Section 505 (e). >' If area separation walls do not extend to the outer edge of . horizontal projections, (balconies, roof overhangs, canopies, marquees and architectural projections) and the projecting elements contain concealed spaces, the wall shall extend through the concealed space to the outer edges of the projecting elements. The exterior walls and projecting elements above- must be of one-hour construction on each side of the area separation wall for a distance equal to the depth of the projecting elements. Walls supporting the exterior walls must be one- hour. Openings in the one-hour walls must be protected with three-fourths-hour assemblies. Section 505 (e) 2. 4/. All area separation walls must extend in a continuous straight vertical plane from the foundation to a point thirty inches above the roof, but may terminate at the underside of the roof sheathing if the roof/ceiling is two- hour construction. Horizontal offsets are not permitted. Section 505 (e) 3. Two-hour area separation walls may terminate at the roof sheathing provided that: - Where the roof/ceiling framing elements are parallel to the walls, such framing and elements supporting such framing shall be of not less than one-hour fire-resistive construction for a width of not less than five feet on each side of the wall. Section 505 (e) 3. Where roof/ceiling framing elements are perpendicular to the wall, the entire span of such framing and elements supporting such framing shall be of not less than one-hour fire-resistive construction. Section 505 (e) 3. C. The entire building shall have a Class B roof covering or a Special Purpose roof. Section 505 (e) 3. 50. No openings in the roof are permitted within five feet of a two-hour area separation wall if parapets are not provided. Section 505 (e) 3. - 2 /12/90 4 5/ Area separation walls, which separate portions of buildings having different heights, may terminate thirty inches above the lower roof level, provided the exterior wall for a height of ten feet ab&e the lower roof is of one- hour fire-resistive construction with openings protected by three-fourths-hour assemblies.. As an alternate the wall may terminate at the sheathing of the lower roof, provided roof/ceiling elements, if parallel to the wall are one-hour construction for a ten foot width along the wall at the lower roof, and supporting elements are one-hour; where the lower roof/ceiling elements are perpendicular to the wall, the roof/ceiling.elements shall be one-hour for the entire span, and supporting elements shall be one-hour. Section 505 (e) 5. Where different roof heights occur, no openings in the lower roof are permitted within ten feet of the area separation wall if parapets are not provided. Section 505 (e) 5. Show the basis for the approved fire-resistive construction elements for the area separation wall, parapet, and ceiling assembly if used in lieu of parapet i.e., item number in Table 43- A, B, C or U.L. Directory, etc. (Note that trusses require two layers of 5/8 inch Type 'X', per Item 21-1.1 in Table 43-C). 51. Parapets of area separation walls shall have non-combustible faces for the upper 18 inches, including counter flashing and coping materials. Provide complete details of the area separation wall(s) to show compliance with Section 505 (e). 5/. Provide a note on the plans stating: "Plumbing and conduit penetrations of the area separation wall shall be of copper or ferrous. No plastic pipe may penetrate the area separation wall". Section 4304 (e). K. BUILDING EEI(r/SmRIFS 5/. Clearly show the maximum building height based on the definition in Section 409. 4. Clearly show if the lower level is a basement or story, based on the definitions in Section 403 and 420. Plot the finish grade (adjacent ground level) on the elevations and dimension the distance to the floor above for story determination. See definition of grade, Section 408. The height and number of stories cannot exceed that shown in Table 5-D. Show the code basis for the height/number of stories as shown. 6/. One additional story would be permitted beyond that shown in Table 5-D, if the building is sprinklered throughout and the sprinkler system is not otherwise required by Section 506 (area) or Section 508 (substitute for one- hour). Section 507. 62,L Towers, spires and steeples shall comply with Section 507, Exception 1. 67. Penthouses shall comply with Chapter 36. 6/. Walls and floors separating dwelling units in the same building shall be of not less than one-hour fire-resistive construction. This does- not apply to hotels. Section 1202(b). 6/. Group R, Division 1 occupancies more than two stories in height, or having more than 3,000 sq. ft. of floor area above the first story shall be not less than one-hour fire-resistive construction, throughout except as provided in Section 1705 (b) 2. Section 1202 (b). 66 Where one-hour fire-resistive construction is required, an approved automatic sprinkler system may be substituted for the one-hour construction, however, the fire sprinkler system shall not waive or reduce fire- resistive requirements for: occupancy separations, dwelling unit separations, exterior walls due to location on property, area separation walls, shaft enclosures, corridor protection, stair enclosures, exit passageways, type of construction separation per Section 1701 and atriums constructed in accordance with Section 1715. Section 508. Provide details of the one-hour fire-resistive construction. Include roof/ceiling assemblies, floor/ceiling assemblies, wall assemblies, post and beam assemblies, gable end assemblies at attics, etc. Chapter 43, chapter 17. 6 Fire-resistive exterior wall construction I shall be maintained through attic areas. Section 4304 (c). 6 Detail how one-hour fire-resistive wall construction is maintained at built-in wall fixtures and behind bathtub and shower enclosures, mailboxes, medicine cabinets, fire - extinguisher cabinets, electric panels exceeding sixteen sq. in. in area, etc. Section 4304 (e). 7/. Detail and reference I.C.B.O. number or other I approval for horizontal fire assembly using trusses. Item 21-1.1 in Table 43-C requires 2 layers of 5/8" Type X gypsum wallboard at the bottom chords of trusses. Section 4303 (b) 8. C L o t4 k. rryj -H--2 vc Q (2. 'U 12/20/89 7I Detail how fire-resistive wall and ceiling 8. C protection will be maintained at all duct ( penetrations such as at bathroom and kitchen hood fans, laundry room fans and dryer vents. Also detail recessed light fixtures. Show duct openings in ceilings, regardless of size, have approved ceiling fire dampers. Section 4303 (b) 6. Roof/ceiling and floor/ceiling assemblies must 7 be of one-hour construction. Detail fire assemblies on plans along with their I.C.B.0. 81 number or other ID number from the Fire Resistive Design Manual published by the Gypsum Assoc. or U.L. number or item number from Table 43-C, U.B.C. Provide cross-section of one-hour corridors serving an occupant load of ten or more. Label corridors on plans as one-hour corridors; specify on the plans all doors as twenty-minute fire assemblies with self- closers or automatic closers with smoke detectors, and all windows as 1/4 inch wire glass in steel frames and all duct penetrations to have fire dampers. Section 3305 (g), Section 3305 (h). Clearly label and identify on the plans the fire-resistive -corr-44or, a'a £part4rn_ 'l1s, £haftc, occupancy separation wa1,4.&é floors. exit GourtL 1056 than ton feet wide- 7/. Detail water heater vents locfedinsidè fire- resistive wall construction or within fire- resistive shafts. Ducts for FAU's or any other air-handling systems between floors must be in rated shafts. Table 17-A; Section 1706 (a), Section 4306 (j). 7/ Clearly identify location and hourly fire- resistive rating of vertical shafts on the plans. Provide construction details showing location of fire dampers and how fire resistivity will be maintained at floors and roofs. Section 1706. 7 Detail column fire protection per Table 43-A in the U.B.C. and specify column impact protection in garage areas per Section 4303 (b) 5. As a minimum, show a twenty-two gauge steel jacket around each column to a height of three feet above the ground for impact protections. 7 / Structural members such as beams supporting more than one floor or roof must be individually fire protected (Section 4303 (b) 6). Detail required protection, per Table 43- A or NRB-250, U.L. etc. 77 Clearly specify minimum thickness of walls and slabs to provide -hour fire- resistive rating per Table 43-B and C. Clearly specify minimum cover forbonded reinforcing at fire-rated columns,_____________ fire-rated beams. Clearly specify minimum cover for prestressed concrete tendons per Section 4303 (c) 3. 7/'. Note that all plumbing and electrical penetrations at occupancy, area, corridor or other fire separation walls shall be as specified in Section 4304 (e). 7/. Detail all furred ceilings as required in I Section 4203. Show fire-retardant treated wood where necessary. Section 302 (d). G. OCCUPANCY SEPARATIONS 87. Storage or laundry rooms that are within Group f R, Division 1 occupancies, that are used in common by tenants, shall be separated from the rest of the building by not less than one-hour fire-resistive occupancy separations. Section 1202 (b). Provide a full one-hour occupancy separation I between R-1 and M-1 or B-i (M-i up to 3,000 sq. ft.) occupancies. Fire protection only on the garage side applies only to R-3/M occupancy separations, not R-i/M occupancy separations. Table 5-Band Section 503 (d). 8/. Provide one-hour fire-resistive door I assemblies in the one-hour occupancy separation. Section 503 (c). . The required three-hour rated occupancy separation between R-1 and B-i occupancies may be reduced to a two-hour rating when the B-i is limited to the storage of passenger vehicles, and the provisions of Section 702 are not applicable (Table 5-B). The two-hour occupancy separation may be further reduced to one-hour, if the aggregate area of B-i occupancy within the building does not exceed 3,000 sq. ft. Section 503 (d). Garages are not permitted to open into a room used for sleeping purposes. Section 1104. 2/12/90 6 9. A B-i occupancy in the basement or first story may be classed as a separate and distinct building for the purpose of area limitation, limitation of number of stories and type of construction, per Section 702, only if the following conditions are met: B-i is Type I construction. B-1/R-1 are separated by a three- hour occupancy separation. C. B-i is restricted to passenger vehicle storage, laundry rooms, entry lobbies and mechanical equipment rooms. (No storage, recreation room, etc.). d. The maximum building height' does not exceed the limits inThble 5-D for the least type of construction. 8,. The Type Iconstruction is required to have 3/4 hour protected exterior wall openings when located within twenty feet from a property line, and no openings are permitted less than five feet. Section 1803 (b). 8A. All openings in floors forming a three-hour separation shall be protected by vertical enclosures above and below the opening. The walls of such enclosures shall be not less than two-hour fire-resistive construction, and openings therein shall be protected by a one and one-half hour assembly. Section 503 (c), Tables 43 - A, B, C and Chapter 43. 90 A OP4 -hour occupancy separation is required between t.-Z. occupancy and the --1 occupancy. Table 5-B, Section 503 (d), Tables 43 - A, B, C and Chapter 43.__ 91. Structural members supporting an occupancy separation must have the same fire-resistive 1 11 ( rating as the separation. Table 5-B, Section 503 (b), Tables 43 - A, B, C and chapter 43. F) 97 Openings in a three-hour fire-resistive ( separation shall be protected by a three-hour assembly, and openings may not exceed twenty- five percent of the length of wall in the story and no single opening shalt exceed-1 ' 20 sq. ft. Section 503 (c), Tables 63 A,B, C and Chapter 43. 71 A two-hour fire-resistive occupancy separation shall be not less than two-hour fire-resistive construction. Openings shall be protected by a one and one-half hour assembly. Section 503 (c), Tables 43 - A, B, C and Chapter 43. 9,1 Occupancy separation wall penetrations must be ' either ferrous or copper and fire-stopped. - Steel electrical outlet boxes shall not exceed sixteen square inches and further, shall not exceed one hundred square inches per one hundred square feet of wall, may be installed and shall be separated by a horizontal distance of twenty-four inches when on opposite sides of a wall. Section 6306 (e). Ducts penetrating one or two-hour occupancy or area separation walls must have fire dampers. A fire door is required for three-hour / separations. Section 4306 (j). 9/. Usable space under the first story, when constructed of metal or wood, shall be protected on the side of the usable space as required for onE-hour fire resistive wall and ceiling construction and the door to the usable space shall be self-closing, of noncombustible construction or solid wood core, not less than 1-3/4 inches in thickness. Section 1703. (?) Show the details and the basis for the rating of the occupancy separation you propose, i.e., f item number in Table 43 - A, B, C; Gypsum i' Fire-Resistive Design Manual; U.L., etc. H. SOUND TRANSMISSION (Title 24, Appendix Chapter 35) 9/. Wall and floor/ceiling assemblies separating / dwelling units from each other and from common space (such as corridors, laundry rooms, common garages, service areas, etc.) must have a listed rating of SIC 50 and IN SO. Show the location of and provide details of the listed wall and floor/ceiling assemblies, and indicate the listing agency and listing number for the tested ratings. 9/. Show how penetrations of assemblies for / piping, electrical devices, recessed cabinets, bathtubs, soffits or heating, ventilating or exhaust ducts shall be sealed, lined or insulated or treated to maintain the required ratings. l. Dwelling unit entrance doors from interior corridors together with their perimeter seals shall have a STC rating of not less than 26. 12/20/89 7 The wall extends to all outer edges of horizontal projecting elements, such as balconies, roof overhangs, canopies, marquees or architectural projections. No openings are permitted for air ducts or similar penetrations, except that openings for pipes, conduits and electrical outlets of copper, sheet steel or ferrous material shall be permitted through such wall and need not be protected, provided they do not unduly impair the required fire resistance of the assembly. Tolerances around such penetrations shall be filled with approved noncombustible materials. Section 1807 should be reviewed for all high- / rise buildings. If emergency warning systems are required, they shall activate a means of warning the hearing impaired. Flashing visual warnings shall have a frequency of not more than 60 flashes per minute. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact________________ oI. \<uiz.-r-- at Esgil Corporation. P T-f -- c Q. C 'J &1 P U LO kAt) o__ (T 144-T 13 L=H1L-S'UL 11r2 (a(-O rO S 11-H i- o c LU9VO e9i1-(1Yfl 0 i) C--i 2 A Cora, O YU 2/27/90 21 Jurisdiction ZLS, VALUATION AND PLAN CHECK FEE Bldg. Dept. Esgil PLAN CHECK NO. o-i.o'o BUILDING ADDRESS L-4u*T2 _13 Lo.'A APPLICANT/CONTACT l?o,..t__ Wk- Locr PHONE NO. Z3.4-31t BUILDING OCCUPANCY .t-2. DESIGNER PHONE 4,c3432-0- .TYPE OF CONSTRUCTION j—L C-r. CONTRACTOR PHONE__________ BUILDING PORTION •.BUILDING AREA VALUATION MULTIPLIER VALUE Air Conditioning Commercial - T Residential 1_@ Res. or Comm. - Fire Sprinklers -@ Total Value 1 4.ST2 Sui1di66 Permit Fee. $. "12 •C)O Plan Check Fee $ 4(9 $ COMMCNTS: SHEET OF. 12/67 ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619)5601468 APPLICANT JURISDICTION U PLAN CHECKER []FILE COPY UP S []DESIGNER DATE: JURISDICTION: VOTO PLAN CHECK NO: &ul SET: PROJECT ADDRESS: \)\LLp,. C2.L.S ig 4zp PROJECT NAME:O PsU LU -L L ' 71) (vL7 2-o wt S .The plans transmitted herewith have"beendorrected where J necessary and substantially comply with the jurisdiction's building codes. fl The plans transmitted herewith will substantiall'y comly with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. I']The plans transmitted herewith have significant deficiencies identified on the enclosed checklist and should be corrected and resubmitted for a complete recheck. n-.. The check list transmitted herewith is for your information. Li The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. fl The applicant's copy of the check list is enclosed.for the jurisdiction to return to the applicantcoi-itact person. F] Theapplicant's' copy of the check list has been sent to: fl Esgil staff did not advise the' 'applicant contact person that plan check has been completed., [j Esgil staff did advise 'applicant that the plan check' has been completed. Person contacted: Date contacted: 'Telephone # ' REMARKS: ( 'J2 ' 1- i21) t 0 rt) I 0 p Is '. a 22-ii ¶Rc.' '. ( L..., 0 By: 'M 1. S bh Vq V*D Enclosures: RLv) ESGIL CORPORATION ' U GA .0 AA Li VW 0 D c ESGIL CORPORATION - /1 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92 123 (619) 560-1468 DATE: TuIv-I !IO IT - ' ITJURISDICTION JURISDICTION: carkh :PLAN CHEC R flFILE COPY PLAN CHECK NO: 90-logo LCPP SET: x. ITUPS DESIGNER PROJECT ADDRESS: l Nr. - PROJECT NAME: 1.l ve1-_flr*_F'arI fl The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. E The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies El identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans. are submitted for recheck. fl•The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applica copy of the check list has been sent to: 7 q Q 1 40 Im Esgil staff didnot advise the applicant contact person that plan check has been completed', +--fiby r.,.ce1. Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone # By: ESGIL CORPORATION LIGA EAA Elvw C3 DM JURISDICTION: Date plans received by plan checker: PLAN CHECK NO.: cW_Ipgp scJPPDate plan check complete d:7/Z'1IgOBy: ',4 PROJECT ADDRESS: 109523 TO: Iae ri 4.L4 c: nic Eli IC)1+ PLAN CORRECTION SHEET FOREWORD: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The items shown below need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), of the Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. PLANS ()Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: 2. To facilitate checking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this check sheet with the revised plans. ()Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made to the plans not resulting from this correction list? Please check. Yes No a - - - - a 4 - - Form No. PCS.41390 BUILDING PLANCHECK - ENGINEERING CHECKLIST DATE: 75-O ITEM COMPLETE PLANCHECK NO. © ITEM INCOMPLETE - NEEDS YOUR ACTION S N R XITEM SELECTED TO D C C C PROJECT ID: Ia H H H E E E LEGALREQUIREMENTS C C C K K K SitePlan Provide a fully dimensioned site plan drawn to scale. Show: north arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width and dimensioned setbacks. Show on site plan: Finish floor elevations, pad elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes, driveway with percent (%) grade and drainage patterns. Provide legal description and Assessors Parcel Number. Discretionary _Approval Compliance 1_4J -4. No Discretionary approvals were required. Project complies with all Engineering Conditions of Approval for Project No. Project does not comply with the following Engineering Conditions of Approval for Project No. Conditions complied with by: Date: FieldReview ______ 7. Field review completed. No issues raised. 8. Field Review completed. The following issues or discrepancies with the site plan were found: Site lacks adequate public improvements. Existing drainage improvements not shown or in conflict with site plan. Site is served by overhead power lines. Grading is required to access site, create pad or provide for ultimate street improvement. FRM001O.DH 08/29/89 Site access visibility problems exist. Provide onsite turnaround or engineered solution to problem. Other: Dedication Requirements . No dedication required. Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 84" x 11" plat map and submit with a title report and the required processing fee. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. The description of the dedication is as follows: __________________________________________________ Dedication completed, Date: By: Improvement Requirements No public improvements required. SPECIAL NOTE: Damaged or defective imDrovements found adjacent to. building site must be repaired to the satisfaction of the City inspector prior to occupancy. . Public improvements required. This project requires construction of public improvements pursuant to Section 18.40 of the City Code. Please have a registered Civil Engineer prepare appropriate improvement plans and submit. for separate pl.ancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. The required improvements are:__________________________________________ Improvement plans signed, Date: By: FRM0010 .OH 08/29/89 14 13. Improvements are required. Construction of the public improvements may be deferred in accordance with Section 18.40 of the City Code. Please submit a letter requesting deferral of the required improvements together with a recent title report on the property and the appropriate processing fee so we may prepare the necessary Future Improvement Agreement. The Future Improvement Agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future Improvement Agreement completed, Date________________ By:_______________ Grading Requirements 13a. Inadequate information available on site plan to make a determination on grading requirements. Please provide more detailed proposed and existing elevations and contours. Include accurate estimates, of the grading quantities (cut, fill, import, export). No grading required as determined by the information provided on the site plan. 15. Grading Permit required. A separate grading plan prepared by, a registered Civil Engineer must be submitted for separate plan check and approval through the Engineering Department. NOTE: The Grading Permit must be issued and grading. substantially comDlete and found acceotable to the City Grading Inspector sign off. Date: By: Miscellaneous Permits '& 16. Right-of-Way Permit not required. 17. Right-of-Way Permit required. A separate Right-of-Way Permit issued by the Engineering Department is required for the following:________________________________________________ 4-18.- . Sewer Permit is not required. 19. Sewer Permit is required. A Sewer Permit is required concurrent with Building Permit issuance. The fee required is noted below in the fees section. Industrial Waste Permit is not required. FRM001O. DH 08/29/8c 21. Industrial Waste Permit is required. Applicant must complete Industrial Waste Permit Applicantion.Form and submit for City approval prior to issuance of Building Permits. Permits must be issued prior to occupancy. Industrial Waste Permit accepted - Date: - By:________________ FeesRequired __ Park-in-Lieu Fee Quadrant: Fee per Unit: Total Fee: Traffic Impact Fee Fee Per Unit: Total Fee: Bridge and Thoroughfare Fee Fee per Unit: Total Fee: Public Facilities Fee required. Facilities Management Fee Zone: Fee: Sewer Fees Permit No. EDU's________________ Fee: Sewer Lateral required: Fee: REMARKS: ENGINEERING AUTHORIZATION TO ISSUE PERMIT BY: Vt', (/k74_ Date: 75 FRM0010.DH 08/29/89 PLANNING CHECKLIST Plan Check No. 90 Addrpc,-q /,"'. D),— Ulm, Planner f/(/1t(-'..i 97$'\,j Phone 438-1161 (Name) Type of of Project and Use Zone Facilities Management Zone Legend Item Complete Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck number that deficiency was identified . Q. Environmental Review Required: YES NO _____ TYPE DATE OF COMPLETION: Compliance -with conditions of approval? If not, state conditions which' require action. Conditions of Approval Discretionary Action Required: YES NO TYPE APPROVAL/RESO. NO. DATE: PROJECT NO. OTHER RELATED CASES: Compliance with conditions of approval? If no., state conditions whi.h require action. Conditions of Approval MOM Coastal YES NO DATE OF APPROVAL: Compliance with conditions of approval? If not, state' conditions which require action. Conditions of Approval UI.'. IL." II." Landscape Plan Required: YES NO See atahed submittal requiethehtsfo landscape plans Site Plan: . 1. Providea fully dimensionedsite plan drawn to scale. Show: North arrow,próperty lines, easements, existing and proposed, structures',Jstreets, é<isting street improvements, right-of-way. width and dimensioned setbacks.. Show on Site Plan Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and driveway. Provide legal description of property. Provide assessor's parcel number. Zoning: 1. Setbacks: Front: I n t. Side: Street Side: Rear: Required Shown Required Shown Required Shown Required Shown Lot coverage: Required . Shown o 0 Height: Required Shown Elm El Parking: . Spaces Required Shown Guest Spaces Required Shown Additional comments ad ,1.,iarks have been made on the building plans. These marked-up plans ray be picked up at the Building Department. These marked- up plans must be resubmitted with the revised plans for this project. Have plans been marked up? YES NO Additional Comments -. o . To ISSUE DATE PLNCK. F PM 8/23 PLAN CHECK 90-1090, 1088 LACUNA Marty: You have copy of Villa De Carlsbad letter from Mike Smith If you,agree with its contents, please sign below, and we can issue the permit. APPROVED: MI 0 AK, FFICLAL DATE:/7 Sillman Wyman & Associates 10671 Roselle St. Ste 200 San Diego, CA 92121 Attention: James Roemen PLAN REVIEW OF LAS VILLAS DE CARLSBAD IMPROVEMENTS 90-1090 Per our conversation of 8-6-90, this office approves the plan for construction of two I-1A occupancies on the first floor of building A. This approval is based in part on identical improvements in Building C which were approved by the State Fire Marshal. As you know The I-lA Occupancy will accomodate 6 or fewer clients of non-ambulatory status. Though Title 24 of the CAC requires direct or semi-direct exiting from each sleeping room, it was the State Fire Marshal's opinion and I concur that the additional protection in the form of automatic sprinklers, one- hour wall construction, supervised smoke detection devices and two-way egress via the corridor, provide at least as safe an environment as your clients would be afforded in a typical single family residential care home. OUTSTANDING PLAN CHECK ITEMS, ESGIL CORP, 7-24-90 Since the UBC does not recognize the T-24 I-1A occupancy classification, This plan was reviewed as an I-i occupancy in order to identify' compliance issues. Those issues are as follows. Si CLEARED. Smoke barrier doors are not a requirement'o'f an I-lA occupancy and are only required to provide separation and horizontal exiting from one licensed facility to the other. • ''. S-2 CLEARED. The requirement for one-hour floor separation is not appropriate unless the R-1 occupancy above is at risk from the I-1A ' occupancy below. Because of like use, the existing floor assembly, automatic sprinklers and supervised smoke detection devices, it is the opinion of this office that the I-1A occupancy on' the ground floor presents no more risk to second floor occupants than the existing apartments. S S-3 CLEARED. According to plans, no shafts communicate between the . proposed I-1A and the remainder of the building. . S-4 CLEARED., Corridors 8 feet in width are not necessary; as the corridors will not be required to' accomodate traffic 'in the form of, hospital beds. S-5 CLEARED. An alarm system supervising each detection device in the. rooms and corridors will be provided. Please comply with items checked on the attached plan check 'report and consider this letter a part of that plan review.. MICHAEL E. SMITH ' •. • ,, . ' . . Fire Marshal cc Marty Orenyak Kurt Culver, ESGIL'Corp. Carter Darnell, Carlsbad Bldg Dept • 2560 ORION WAY CARLSBAD, CA 92008 TELEPHONE (619) 931-2121 Qtitp at Car1bab FIRE DEPARTMENT - PLAN CHECK REPORT PAGE 1 OF APPROVED DISAPPROVED PLAN CHECK# A/1 PROJECT /1< /ii..AA ADDRESS Z11 ARCHITECT L LM'//,t1 -c ,-1,J ADDRESS PHONE OWNER /4/t/'6it XccYz/ 'i7J4- ADDRESS PHONE OCCUPANCY 1 14 CONST. V 'V TOTAL SQ. FT. STORIES / DSPRINKLERED DtTENANT IMP. APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS: PLANS, SPECIFICATIONS, AND PERMITS Provide one copy of: floor plan(s); site plan; sheets Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project. Provide specifications for the following: Permits are required for the installation of all fire protection systems. (sprinklers, stand pipes, dry chemical, halon, CO2, alarms, hydrants). Plan must be approved by the fire department prior to installation. The business owner shall complete a building information letter and return it to the fire department. FIRE PROTECTION SYSTEMS AND EQUIPMENT The following fire protection systems are required: Automatic fire sprinklers (Design Criteria O Dry Chemical, Halon, CO2 (Location: O Stand Pipes (Type: .Fire Alarm (Type/Location:. JL. 7. Fire Extinguisher Requirements: ELOne 2A rated ABC extinguisher for each _________ sq. ft. or portion thereof with a travel distance to the nearest extinguisher not to exceed 75 feet of travel. o An extinguisher with a minimum rating of to be located: El Other: Additional fire hydrant(s) shall be provided EXITS Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. .........._10. A sign stating, This door to remain unlocked during business hours" shall be placed above the main exit and doors .iLii. EXIT signs (6" x 3/4" letters) shall be placed over all required exits and directional signs located as necessary to clearly indicate the location of exit doors. GENERAL Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and hazardous chemicals shall comply with Uniform Fire Code. Building(s) not approved for high piled combustible stock. Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids. If high stock pil- ing is to be done, comply with Uniform Fire Code, Article 81. Additional Requirements. I-, I 1'4 JV'AJ'(- I Comply with regulations on attached sheet(s). Plan Examiner ' 47, Date Report mailed to architect _______ Met with _____ Attach to Plans