HomeMy WebLinkAbout1088 LAGUNA DR; ; CB910986; Permit,BUILDING P E R M I T 10/25/9). 12: 24 Pag&~ ·1 of 1 Job Address: 1088 LAGUNA Permit Type: APARTMENTS Parcel No: 155-272-19-00 Valuation: 165,200 Construction Type: VN, Occupancy Group: I1/R1 Description: CHANGE FROM ~ BUILDING C DR Str: Class Code: BLDG C R OCCUPANCY TO I-1 1ST AND 2ND FLOORS Permit Project Development Fl: Ste: No: CB910986 No: A9101214--- No l/L {/?5 Status: ISSUED Applied: 07/01/91 A2r/Issue: 10/25/91 49ij-tiV~.f'ij.aOQ9i :Oleo 02 619 234-4316 C-PRMT 1081-00 CONTRACTOR 234-4316 *** *** CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 I PERMIT APPUCATION City of Carlsbad Building Department 2075 Las Palms D[-, Carlsbad, CA 92009 (619) 438-1161 1. PRRMll l"YPk A -0 commerc,al DNew Building O Tenant Improvement B -D Industrial D New Building D Tenant Improvement C -~ Residential D·Apartment D Condo D Single Family Dwelling lf1 Addition/ Alteration D Duplex D Demolition D Relocation D Mobile Home D Electrical D Plumbing D Mechanical D Pool D Spa D Retaining Wall D Solar D Other ___ _ oz. 2. PRClJF.CT INFORMATION FOR OFFICE USE ONLY Address 1088 Laguna Drive Bmldmg or Smte No. Nearest Cross Street Jeff er SO n LEGAL DESCRIPTION Lot No. sulxhv1S1on Name/Number Omt No. Phase No. City of Carlsbad Portion of Section 6, Township 12 South, Range 4 West - cHEcR BEWW IF sDBMII IED: D 2 Energy Cales if! 2 Structural Cales a 2 Soils Report D l Addressed Envelope ss 155-272-19 DESCRIPTION OF WORK pgra e por 1 ons 0 # OF STORIES ADDRESS NAME CI'IY 4 . .APPUCANT O cON'IRACIOR STATE ZIP CODE DAY TELEPHONE tlAGEN'I FOR cON'l'RACIOR tlOWNEll rlfiAGENI FOR OWNER NAME Delorie Jacobsen ADDRESS 1060 8th Ave. , #405 CITY San Di ego STATE CA ZIP CODE 92101 DAY TELEPHONE ( 619) 234-4316 s. PRoPillri' OWNER. . NAME Villas de Carlsbad, Ltd. ADDRESS 1060 8th Ave., #405 cr'IY San Di ego STATE CA ZIP CODE 92101 DAY TELEPHONE (619) 234-4316 6. mN'I'RACluR NAME Casitas Development .cI'IY San Di ego STATE CA ADDRESS 1060 8th Ave., #405 ZIP CODE 92101 DAY TELEPHONE (619) 234-4316 DESIGNER NAME s; 1 i man/ l~yma n STATE UC.# 445251 LlCENSE CIASS 8 Cl'IY BUSINESS UC:.# ADDRESS 9609 Waples Street, Ste. 200 cI'IY San Di ego STATE CA ZIPCODE 92121 DAYTELEPHONE 453-4320 STATELlC.# :C7585 1. WOIU<filtS' wMP£NSA.110N Workers' Compensation beclaratlon: I hereby afhrm that I have a cert1hcate of consent to self-msure issued by the D1rector of lndustnal Relations, or ·a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). l''t? f,l. l', : ~. -. INSURANCECOMPANY Cal Comp POUCYNO.W1700631 EXPIRATIONDATE 6/30/92 eeruhcate of Exemption: I certify that m the performance of the work for which this permit IS issued, I shall not employ any person m any manner D D D aratlon: ere y a ,rm at ontracto s cense o owmg reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Cqde: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees,. provided that such improvements are not intended or offered·for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of.sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's Llcense Law). I am exempt under Section _______ Business and Professions Code forthis reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's Llcense Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500)). SIGNATIJRE DATE coMPLETE THIS SECtioN FOR NON-RESIDENTIAL BUlLDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? h I. Dfi YES b 'Id' ~ NO ' ed b · ' f h ' II ' I d" . . I" d' . 1 Is t e app 1cant or utµre u1 mg occ.!1'ant reqmr to o tam a permit rom t e air po uuon contro 1stnct or a1r qua 1ty management 1stnct. C YES ~ NO Is the facility to be constructed Within.J,000 feet of the outer boundary of a school site? 0 YES [1 NO IF ANY OF nm ANSWERS ARE~ A FINAL CER1Il1CATE OF oa;m>ANCY MAY Nar BE ISSUED AFfER JULY 1, 1989 UNLESS nm APPUCANT HAS MET OR IS MEETING nm REQUIREMENTS OF nm OFFICE OF EMERGENCY SERVICF,S AND nm !JR POU.UTION CDNTilOL msnucr. 9. wNSIRUCllON LHNDING AGRNCY . . I hereby afhrm that there 1s a construction lendmg agency for the performance of the work for which this permit 1s issued (Sec 3097(1) C1vil code). LENDER'S NAME LENDER'S ADDRESS to. APPLlcANT cmtl1FlcA110N I certify that I have read the apphcauon and state thanhe above mformat1on 1s correct. I agree to comply with all City ordmances and State laws relating to building construction. I hereby authorize representatives of the G,jtyof Carlsbad to enter upon the above mentioned property for inspection purposes. I AISO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS nm CflY OF CARISBAD AGAINSf AIL UABillTIES, JUDGMENTS, CDSTS AND EXPENSF.S WIIlCH MAY IN ANY WAY ACDUJE AGAINSf SAID CflY IN CDNSEQUENCE OF nm GRANTING OF nns PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Expiration. ·Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). DATE: _____ _ Applicant PINK: Finance I U!fSCl!!!PYUD Ill§f!CTIOH () L OATJ:,________ INSPECTOR r!': · ~ (J<---- PERMIT t q/-;/6 Pt.ANCIC t ------ TIME ARRIVE: . TIME LEAVE: ----- co ~VL DESCRIPTION ACT COMMENTS -----f1rf-~b - ---- PDIIITS 6/15/19 - - c~ol~ , United States Testing Company, 1'1C, Engineerjng & Support Services · 3467 Kurtz Street, San Diego, CA 9211 O (619) 225-9641 Job No: Job Nama: Address·~ 01:j.39600 VILLAS DE CARLSBAD REl10DEL, BLDG "C" 1088 LAQUNA DR. CARLSBAD, CA 00000 CITY OF CARLSBAD BLDG. INSPECTION DEFT. 2075 LAS PALMAS DRIVE CARLSB}\D, CA 92009 i?lan Number: Permit{ 91-986 Application:. 'Dir;;tribUted To:· SOUTHCOAST·RENOVATION CITY OF CARLSBAD UNITED STATES TESTING Report .No,: 8862 Date:·$eptember 28, 1992 ENGINEER: S. FRANI<;oM RCE CA37766 FIELD IHSPECTJO~-BEPOR'l' D~TE OF IHSPECT!OH: -09/22/92 I'l'EH , Holddowns LQCA'llOH OF WORK INSPEC'lED: New bolddox,ms at riew ,;,penings. · 1" threaded rod -West shower, room ClOSB. 'Dining rooms CilOA and c11oc. Hilti HVA adhe1?ive anchor system. HEA M20x170 (7/S"x'G 5/8"} -2 cart'l'.i,dges per hoJ,,e. · Room C108B: New opening to hallway C105, east jaI!ll;); or;i.gihal .hole hit rebar _at 9", new -hole offset per Mr •. Jim Roman. CONTRACTOR: South Coast Renovations ACCEP.r I REJECT X · 7HE HORR D~CRIBED ABOVE WAS PERFORMED IN ACCORDANCE WITH 7HE .P.ROJEC'l PLANS AND SPECIFICA'lIONS. INSPECTOR: Eric Checketts JOB HOURS: 4,(} START TIME: 10:12 NUHBER:. 538 STOP TIME: 12:10 THIS REPORT DOES NOT RELIEVE THE CONTRACTOR OF HIS ~SFONSIB:i:LITY TO BUILD PER THE PL,AHS, SPECIFICATIONS AND ¥,L APPLICABLE CODES. ~ , . I he &&:!W= Ii..... r _ / / ,-s s (,/2-aA: rr,,,v~ fJIA....S CN-Ck.. 1/2 ~IA-s oe ~A!.~'° • ._),~· ~.-..J ~~// ..,t/df£ ~ f'<A,V'5 bJal'Gos 7' /4 ~e:.f ~r • -.,. 1,t A e:J ~ At2e4 S~"-~// W,e...e.. .~e, tc,.;<S~~n/'J /fr ~A.A-5-G UNt.S f-'/2-1<7/l.. 77> eJCCoj'/.J-JJ ~/ eit~"-~!:sf!. 1/ aw.,s/,,,.,,.;c.-h-~.s .,v~;. ~<,1,-1 ,,_.J ·-14,_ A-f;/AC,._/ //.~se • -rk"< ,s ~e~~tvl,k -lo J~ ~c ~ ~1J tJ,_ , -4.-\,o ~;us I JGd,C ./c, ... or ~I' 74~ ,c,_ ~ k~ ~Sc:) 1· . l· City of Carlsbad ca-,,,,,,.oo,a-2wn,.,.,,,,no1 August 12, 1991 Delorie Jacobsen Sillman/Wyman 9609 Waples Street 200 San Diego, Ca 92121 Plancheck 91-986, Villas De Carlsbad This was submitted as "Upgrade portion of first and second floors to one hour constructio~". What it appears to be is a conversion to an I-1 occupancy from an R occupancy. First, will you please state in writing what you are trying to accomplish and for whom so we can describe on the building permit what is being issued. Second, please refer to the attached correction list: There is no documentation in our files showing approval of anything on that list. There are three appeals; more units for disabled, low level exit signs and visual warning devices. These _appeals should be made in writing to the Director, Martin Orenyak, who is the Building Official. There are several itenµ;· you want the inspector to verify. Our inspe~tors determine whether or not the construction agrees with the approved plans. Ple---=--~ote absolutely on the plans the following items, and document atements: 71A,C; 163-65; 291; 299;309. - eas.e obtain written approval from the 302, 304,305,10, after which the ----~ ~ CARTER DARNELL, PLANCHECK COORDINATOR c: Kurt Culver, Esgil Corporation Fire Department for Items 294, Building Department will review. Jim llarris, Assistant Fire Marshall To~y Mata, Principal Building Inspector . . . . 2075 Las Palmas Drive • Carlsbad, California ·92009 • (619) 438-1161 'II.,_' FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING ('FlRE . \ PLANNING U/M WATER PLAN CHECK#: CB9;I.0986 PERMIT#: CB9109·86 PROJECT NAME: CHANGE FROM R OCCUPANCY TO I-1 BUILDING C 1ST AND 2ND FLOORS ADDRESS : \ro:a-~r-tAGUNA DR. j 7 CONTACT PERSON/PHONE#: MH/ SEWER DIST: CA WATER DIST: CA DATE: 07/15/92 PERMIT TYPE: APT INSPE.CTED;7~ DATE BY: ~~c.L-INSPECTED.: /0~/f.J---APPR~VED ~ DISAPPROVED . , INSPECTED BY: INSPECTED BY: . _.......,.. _______ _ COMMENTS: DATE INSPECTED: DATE INSPECTED: APPROVED APPROVED DISAPPROVED DISAPPROVED ?LS !k)t-t-D {!lf-fef. __,, K'vf-1-' t"v / Ve i 5l tJ 5~ ~'7 e., ,JJ-~ 9/4 PLANCHECK 91-986 9/4/91 I think you should approve Items 1 to 4 above. ITEMS 1 to 4 APPROVED: DATE: -----~-~------------------BUILDING OFFICIAL Kurt says 1 and 4 never discussed. 2 and 3 were discussed with no conclusions. Jim Harris has approved plans but his approval conditions 8' corridors on second floor. Owner says he wants p~rmit.Y- ·; ' -I l ' ., City. of Carlsbad Mi• 14 •14 ·kl 4; I ,t§ Ii I May 15, 1992 Ron McElliott Villas de Carlsbad, LTD 1060 8th Avenue, Suite 405 San Diego CA 92101 RE.CE\VED MA'1 2 9 This letter confirms our conversation of May 15, 1992. As we agreed, the City will allow occupancy of the second floor while the first floor is incomplete. provided all of the following conditions are maintained: 1 . · Fire Marshal's approval of said conditions. 2. There will be an on premise security person placed as a fire watchman at all times when construction crews are not onsite. 3. The duration of the firewatch will be from the time the second · floor Certificate. of Qccupancy is granted until .all drywall improvements are complete on the first floor. 4. Th~ fire watchman will have access to fire extinguishers of a type · and number specified by the Fire Marshal. 5. At no time will the fire sprinkler system and the alarm system be out of operation at the same time. _ 6. The automatic sprinkler system shall be placed in service each night prior to the workers leaving the site·. As signed below, these conditions are to be adhered to without exception. The failure to do so may result in· the revocation of second floor occupancy unti.1 all passive and active fire resistive elements are complete. Please acknowledge this agreement below and return to this office prior to requesting final inspection of .the second floo~ =---=--;;==:--~ . . ~ z:_~~4-' PAT KELLEY oc::::: MIKE SMITH Principal Building_ Inspector Fire Marshal ~ . ' . , I R -__ , ~. I ' ' • = c: Community Developmen~ Director 2560 Orion Way • Carlsbad, California 92008-7280 • (619) 931-2141 . CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB910986 FOR 07/15/92 DESCRIPTION: CHANGE FROM R OCCUPANCY TO I-1 BUILDING C 1ST AND 2ND FLOORS TYPE: APT . INSPECTOR AREA MP PLANCK# CB910986 OCC GRP Il/Rl CONSTR. TYPE VN STR: FL: STE: JOB ADDRESS: 1088 LAGUNA DR APPLICANT: VILLAS DE CARLSBAD, CONTRACTOR: CASITAS DEVELOPMENT OWNER: LTD. PHONE: 619 234-4316 REMARKS: MH/ SPECIAL INSTRUCT: COLLEEN (FIRE) WILL BE TOTAL TIME: --RELATED PERMITS--PERMIT# AS920043 FA920003 TYPE ASTI FALARM PHONE: 234-4316 ~/ / --PHONE: ~ INSPECTOR~• · THERE 9 AM STATUS ISSUED ISSUED CD LVL DESCRIPTION ACT COMMENTS 19 ST Final structural 29 PL Final Plumbing ~----------- 39 EL Final Electrical 49 ME Final Mechanical ---------,------------- ------------------'---- -------------------------"---- ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 070792 Frame/Steel/Bolting/Welding AP MP OK TO DROP TILE 070192 Interior Lath/Drywall PA MP NURSES AREA 062992 Frame/Steel/Bolting/Welding PA MP· OK TO ROCK NURSES AREA 062992 Rough/Topout PA MP 062992 Rough/Ducts/Dampers PA MP 060392 Frame/Steel/Bolting/Welding AP MP OK TO ROCK LIDS@ BTHRM 052992 Frame/Steel/Bolting/Welding NR MP MET W/FIRE 052792 Interior Lath/Drywall AP MP OK TO TAPE 2ND FLOOR 052692 .Interior Lath/Drywall NS MP NO APP PLANS 05229-2 Interior Lath/Drywall NR MP NO APPROVED PLANS 052192 Interior Lath/Drywall CA . PY PLAN CHANGE NOT APPROVED 051892 Interior Lath/Drywall NR MP 051392 Interior Lath/Drywall co MP ' 051292 Rough Electric AP MP WALLS ONLY 2ND FLOOR -.... -,--...... DATE: ESGIL CORPORATION AUGUST 5, 1991 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, .CA 92123 (619) 560-1468 OAPPLICANT JUR,!SDICTION: CARLSBAD [g JURiSDICTIQN.) OPLAN CHECKER QFILE COPY QUPS r,DESIGNER PLAN CHECK NO: 91-986 SET: II _ _. PROJECT ADDRESS: 1088 LAGUNA DR., BLDG. C PROJECT NAME: VILLAS DE CARLSBAD -ADD I-1 OCCUPANCY D D 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified on the attached sheets are resolved and checked by building department staff. The plans transmitted. herewith have significant deficiencies identified on the enqlosed check list and should be corrected and resubmitted for~ complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. D Th~ applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. r-:-, . this transroi ttal · ~ Th_e a·pplicant' s copy of t~~;...-:t.'1"St nas been sent to: s·ILLMAN/WYMAN, .1,0671 ROSELLE ST., #200, SAN DIEGO, CA 92121 r:J Esgil staff did not advise. the applicant contact person that ~ plan che~k ha~ been completed~ ~ Esgil staff did advise applicant that the plan check has ~ been completed. Person contacted: JIM ROMAN ------------- Date contacted: 8/5/91 ----,--...-----Telephone # APPT. --------0 REMARKS: ___________ __... _________ _ By: l\URT CULVER Enclosures: -----------ESGIL CORPORATION OGA DAA ORN ODM t V CITY OF CARLSBAD PLAN CHECK NO. 91-986, II VILLAS DE CARLSBAD, ADD I-1 OCCUPANCY AUGUST 5, 1991 The designer stated following outstanding 71) A. that the City has resolved corrections (please verify): all of the )c. Please verify whether the statement made in Note 18 on sheet A2 is correct. City to determine if the "Firemaster Bulk" shown in L165. the Note 9 on sheet A2 may be used as an equivalent to extending drywall behind bathtubs (to maintain the one- hour fire-resistive integrity of the walls). The designer would like the inspector to verify that exit signs and exit illumination comply with the UBC. I .. ..+-.284. For I occupancies, Chapter 10 in Title 24 requires that more I.AA--V units be accessible for the disabled than that required for R occupancies (the current use). The designer would like to appeal this to the City. ~-2. The designer would like to appeal the requirement for low 29i. 294. l'-1\0 level exit signs to the-City. The designer would like to appeal the requirement for visual warning devices for the hearing impaired to the City. The inspector should verify the one-hour construction shown at Notes 2, 4 and 10 on sheet A2. The designer stated that the City would allow phasing of this project wlthout requiring ~J:.a separation~ walls. Please verify. '/\.)t!)-A-P:s2.. ~~ /." ,,X r 1o t--~• ~ ~&«>{2--? Notes 7 and 8 on sheet A2 specify that non-bearing walls may be non-fire rated. UBC Section 1705 only allows this for apartments and hotels • .:"-' 296. Please verify 9n City records the floor areas reported on ~ 299. ~01, sheet A2. At Note 14 on sheet A2, the drywall that the inspector is to verify should be 5/8" Type X. The designer stated that sheet A2 as equivalent to verify. the City one-hour has accepted Note 17 on construction. Please \ CITY OF CARLSBAD PLAN CHECK NO. 91-986, II VILLAS DE CARLSBAD, ADD I-1 AUGUST 5, 1991 ~,-) !t>N~ ,'LL;~~~~,--- e designer stated tha the existing bathroom exhaust fans fire-rated corridor, yet aren't No. in UBC Section 4306(j). He further has accepted this. Please verify. 8'-wide corridors are required per UBC pass overhead above th 26 gauge as specif' stated that the City City to deh.¢rmine) if Section 3321. { City to determine if the entire building is to be made of one-hour construction, per AB 1989 (the 3rd story isn't). 306. Justify not replacing plumbing and electrical materials to comply with current codes for an I occupancy. 308. Show fire sprinkler activation per Item 5 in UBC Section 1002(b). ~09. Inspector to ~ at there are no duct penetrations of iers. {) ~ TO ~O'"T"<£-. ol',} ~~~ , f ,4-,-Ji. 1 o ~ "-\ w\ LL-l-0-t0 ~ If you have any questions, please contact Kurt Culver of Esgil Corporation at (619) 560-1468. Thank you. ·ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA f}2123 (619) 560-1468 DATE: Tu.41 10 t /qq/ 7 JU·ISDICTI0N" JURISDICTION: Cadshael · PLAN CHECKER QFILE COPY QUPS . PLAN CHECK NO: SET: T ' PROJECT ADDRESS: !Qf?~ ~-{Jo ~I~. C ODESIGNER PROJECT NAME: y,· /lg,5 ae. iarJ-sbad' -Ade/ L-/ t2<cuf1aflo/ D 0 D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified~-~---~--~~--are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plan.s are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. ~ The applicant's copy of the check list has been sent to: De.lor-ie,.. Jq.cabs·~~::··:.· i0(p0 ~th.-Ave.:; -=#=-'-/OS ~vi h,tjo "fo<ID/. ~ Esgil staff did not advise the applicant contact person that plan check has been completed.· O Esgil staff did advise appli~ant.that the plan check has been completed •. Person contacted: ___________ _ By: ----~ ........ ------~""----~---ES GIL CORPORATION 7 '2- OGA OAA D RN ODM ' ,, . ~ . PI.AH CIEClC HO. __ '9...!,..!..f-_1...i..~...:::.:,,,/e,:;_.. ______ _ JURISDICIIOH: __ .:,..C_.@::.c<1.C-! .... ~"""b-...et.=e{...,_ _____ _ OCCUPANCY:_-=:r:=---.:..1_,_/ ....... R...;a:·_-,_.;..1 _____ _ BUILDING USE: Ca.re.: F; c , I, +y ffl'E OF CONS'IRUCIIOH: Y-/ b r. '>fa AC'l'UAL ARF.A: ]]-I = '?< 0 ,' C, 5 0 K-I ::: er, tpO ALLOWABLE ARF.A:__,f./.,__,__.(2.,_1.,_'f.,..v_=_,=--'-9_'{.,_____.,,:2"'"""/L;c.._ __ _ I Sl'ORIES: _____________ ...;.... ____ _ BEIGHI: __ ..... /,/...._._ ____________ _ SPRINKLERS:_....,¼,_,,e-..,5..__ ___________ _ OCCUPAN'.t· toAD:_ ..... AJ.........,!ec ________________ _ Date plans received by jurisdiction: 7 /1 / "'1 I Date plans. received by Esgil Corp.: 7 /z/q I Date initial plan check completed: Applicant contact person: Tel. ___ dl.""'""'3 ..... 'f .... -_...._'f 3,.____J(e.___ ________ _ FORF.WRD: PLF.ASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Piumbirtg Code, Uniform Mechanical Code, National Electrical code and state laws regulating energy conservation, noise attenuation and access for the disabled. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Present california law mandates that construction comply with Title 24 and the applicable model code editions adopted, with or without changes, by the various state agencies authorized to propose building regulations for enforcement at the local level. Code sections cited are based on the 1988 UBC. The circled items listed need clar.ification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1988 Uniform Building Code, the approval of the plans does ·not· permit the violation of any state, county_ or city law. To speed up the recheck process, note on this list (or·a copy) ·where each correction item has been addressed, i.e., plan sheet, specification, etc. Be sure to enclose the marked up list when you submit the revised plans. HO'IE: PAGE NUHBERS ARE HOT IH ~CE AS PAGES HAVING HO rnMS HEEDING CORRECTIONS WERE DELETED. List No .. SO, GENERAL COMMERCIAL, WITHOUT ~GY OR LOCAL ORDINANCE OR POLICY SUPPLEMENTS (1988 UBC) ,, ' A. B. !· f- I· /· }: Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, (619) 560-1468. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction's building department, Provide the site address and a vicinity sketch on the Title Sheet. Provide the names, addresses and telephone numbers·of the owner and the responsible design professionals on the Title Sheet. <Affisheets of the plans and the first sheet of ~calculations are required t6 be signed by the California licensed architect or engineer responsible for the plan preparation. Please include the California license number, sea date of license expiration and the date e plans are signed. Business and Professions Code. M&.":.. Show on the Title Sheet all buildings, structures, walls, etc. included under this application. Any portion of the project sh9wn on the site plan that is not included with the building permit application filed should be clearly identified as "not included11 on the site plan or Title Sheet. Provide a Building Code Data Legend on·the Title Sheet. Include the following code informationfor each building proposed: Occupancy Group · Description of Use Type of Construction Spripklers: Yes or·No Stories Height Floor Area Justification to exceed allowable area in Table 5-C. (if applicable) Justification to exceed allowable height or stories in Table 5-D. (if applicable)' 2/15/90 ~- @ C. r· Provide a note with the building data legend stating that yards used for area increases shall be permanently maintained. Indicate on the Title Sheet whether or not a grading permit is required for this project. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1988 UBC, UMC and UPC and J;M:i NEc. 1crqo Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building· which exceed the -quantities listed in UBC Tables 9-A and 9-B. Specify the uses of all rooms or areas. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show north arrow, property lines, easements, streets, existing and proposed buildings and structures. Provide a statement on the site plan stating: "All property lines, easements and buildings, both existing and proposed, are shown on this site plan". Clearly designate on the site plcµi existing buildings to remain, existing buildings to be demolished, buildings to be constructed under this permit and any proposed future buildings. Clearly designate any side yards ·used to justify increases in allowable area based on SectiQn 506. Show on the site plan all proposed walls, retaining walls and fences. Specify their heights on the plans. Provide construction details if a part of this permit. Clearly dimension building .setbacks from property lines, street centerlines, and from all adjacent buildings and structures on the site plan. 2 ;"t' ,. j· D. 1· 2~. Show and dimension on the site plan all building projections including eaves, balconies, cornices and similar ·appendages extending beyond the exterior walls. Show on the site plan, or provide the grading plans, showing finish floor elevations, elevations of finish grade adjacent to buildings, drainage patterns and locations and gradients of ~ut or fill slopes. Show dimensioned parking layout including any ·required disabled access spaces. Show the location of any designated flood plains, open space easements, or other development restricted areas on the site plan. LOCATION ON PROPERTY When two or more buildings are on the same p~operty, the buildings shall have an assumed property line between them for the purpose of determining the required wall and opening protection and roof cover requirements, per Section 504 (c). An exception is provided if the combined area of the buildings is within the limits specified in Section 505 for a single building. If this exception is used, show how the building(s) will comply with Section SOS. When a new building is to.be erected on the same property as an existing building, the location of the assumed property line witjl relation to. the existing building shall be such ·that the exterior wall and opening protection of the existing building meet the criteria of Table 5-A and Part IV. Section 504 (c). Buildings over one story and containing courts shall have an assumed property line .for the purpose of determining required wall and opening protection of court walls, per Section 504 (c). See possible· exception. Please show how the court walls will be made to comply with Section 504 (c). The exterior walls less than ___ feet to a property line or an assumed property line, shall be · fire-rated construction. Section _____ 03. Exterior walls shall have a 30· .inch parapet when less than __ ,..,... ___ feet to · a property line or an assumed property line. The uppermost 1811 of . such parapets shall be noncombustible. (see exception, Section 1709,) The exterior wall shall have protected openings (3/4 hour) when closer than ___ feet to a property line or an assumed property line. Section _____ 03. 2/14/90 t· r· +· The exterior walls shall have no openings when closer than -e-----feet to a property line or an assumed property line. Openings include windows, doors, scuppers, vents, etc. Section. ____ 03. Eaves over required windows shall be not less than 30 inches from side and rear property lines. Section 504 (a). Combustible projections located where openings are required to be protected shall be heavy timber or one-hour construction. Section 1710. Projections may not extend more than 12 inches into areas where openings are not allowed. Section 1710. Projections over public property must comply with Chapter 45. Projections may not extend more than one-third the distance from the exterior wall to the property line or one-third the distance from an assumed vertical plane located where fire- resistive protection of openings is first required, whichever· ·is least restrictive. Section 504 (b). Fire-resistive exterior wall shall be maintained through Section 4304 (c). construction attic· ·areas. When openings are required to be protected due to location on property, the sum of openings shall not exceed 50 percent of the total area of the wall in each story. Section 504 (b). A covered pedestrian walkway must comply with the requirements in Section 509. Exterior exit balconies cannot be located in an area where openings are required to be protected. Section 3305 (i). Exterior stairways shall not project into yards where protection of openings is _,_.required. Section 3306 (n). Yards or courts serving as required exits for 10 or more occupants must be at least 10 feet wide or have walls of one-hour construction for a height of 10 feet above the court or yard grade. Openings shall be protected by fire-assemblies having a rating of not less than three-fourths-hour. Section 3301 (b) definition and Section 3311 (d). 3 ' ' ,. i,-.1 r· E. F. 'Structural elements exposed in walls required to be fire-resistive construction due to location on property must have the same fire- resistive rated protection as the wall, or as required for the structural frame for the type of construction, whichever is greater. Table 17-A footnote 1, and Section 1702. mechanical ·equipment and similar openings where openings are Openings for scuppers, vents, foundation vents have to be protected required· to be protected. Tabie 5-A, Section _03. BUILDIBG ARFA When a building has more than one occupancy, the area shall be such that the sum of the ratios of the actual area divided by the allowable area for each occupancy shall not exceed one. Section 503 (a). As shown, the building(s) is/are over area for the Type of Construction shown. Table 5-C. No single story can exceed the basic area allowed by Table 5-C plus the increases allowed by Section 506. Unless considered a separate story, the flo~r area of a .mezzanine shall -be included in calculating the area of the story in which it is located. Section 505 (.c) •. A basement need not be included in the total allowable area, provided such a basement does not exceed the area permitted .for a one story building. Section 505 (d). ARFA SEPARATION WALLS Area separation walls may separate portions of a building and allow each portion to be considered a separate building; however, the area separation wall must be four-hour in Type-r, II-F.R., III and IV buildings; and two-hour. in Type II-one-hour, Type II-N and Type V buildings. Section 505 (e) 1. Openings in four-hour area separation walls are required to be·protected with three-hour fire- resistive assemblies, and 1-1/2 hour fire- assemblies in two-hour area separation walls. Section 505 (e) 1. Openings in area separation walls are limited to 25 percent of the length-of the wall in each story. Section 505 (e). 2/14/90 If area separation walls do not extend to the ·outer edge of horizontal projections, (balconies, roof overhangs, canopies, marquees and architectural projections), and the .projecting elements contai~_concealed spaces, the wall .. shal-1 extend through the concealed spaces to the outer edge of the projecting elements. The exterior walls, and projecting elements above, must be of one-hour construction on each side of the area separation wall for a distance equal to the depth of the projecting elements. Walls supporting the exterior walls must be one- hour. Openings in the one-hour walls must be protected with three-fourths-hour assemblies. Section 505 (e) 2. All area separation walls must extend in a continuous _straight vertical plane (no horizontal offsets) from the foundation to a point 30 inches above the roof, but may terminate at the underside of the roof sheathing if the roof/ceiling is two-hour construction. Two-hour area separation walls may terminate at roofs of entirely noncombustible construction. Section 505 {e) 3. Two~hour area separation walls may terminate at the roof sheathing provided that: a. Where the roof/ceiling framing elements are parallel to the walls, such framing and elements supporting such framing shall be of not less than one-hour fire- resistive construction for a width of not b. c. d. · less than 5 feet on each side of the wall. Where roof/ceiling framing elements are perpendicular to the wall, the entire span of such framing and elements supporting such framing shall be of not less than one-hour fire-resistive construction. Openings in the roof shall not be located within 5 feet of the area separation wall. The entire building shall have a Class B roof covering or a Special Purpose roof. Section 505 (e) 3. 4 ' :I t· G. Area separation walls, which separate portions of buildings havinK different heights, may terminate 30 inches above the lower roof level, provided the exterior wall for a height of 10 feet above the lower roof is of one-hour fire- resistive construction with openings protected ·by three-fourths-hour assemblies. As an altepiate, the wall may terminate at the sheathing of the lower roof, provided roof/ceiling elements, if parallel to the wall, are one-hour construction for a 10 foot width along the wall at the lower roof; where the lower roof/ceiling elements are perpendicular to the wall, the ;roof/ceiling elements shall be one-hour for the entire span. In each case, construction supporting the roof/ceiling shall ·also be one-hour construction. Section 505 (e) 5. No openings in the lower roof are permitted within 10 feet of the area separation wall if parapets. are not provided. Section 505 (e) 5. Show the basis for the approved fire-resistive construction elements for the area separation wall, parapet, and ceiling assembly if used in lieu of parapet, i.e., Item Number in Table 43- A, B, C or U.L. Directory, etc. (Note: Trusses require two layers of 5/8 inch -Type 'X' drywall, per Item 21-1.1 in Table 43-C.) Parapets of ~ea separation walls shall have noncombustible faces for the uppermost 18 inches, including counterflashing and coping materials. Section 505 See the attached article, "Area Separation Walls Revisited", and incorporate appropriate data and details ·on-your plans. Provide complete details of the area separation wall(s) to show compliance with Section. 505 (e) 1-5. Provide a note on the plans stating: "Plumbing and conduit penetrations of the area separation wall shall be of copper or ferrous. No plastic pipe may penetrate the area separation wall". ·section 4304 ( e). BUILDING BEIGHr/S'l'OBffl·, Clearly show the maximum _bµilding height based on the definition in Section 409. Clearly show if the lower level is a basement or story, based on the definitions in Section 403 and 420~ Plot the finish grade {adjacent ground l.evel) on-the elevations and dimension the distance,to the floor above for story determination. See. definition·of grade, Section 408. 2/14/90 H. 6/· 0 1· ® The height and number of stories cannot exceed -that shown in Table 5-D. Show the code basis for the height/number of stories as shown. · One additional story would be permitted beyond ·that shown in Table 5-D if the building is sprinklered throughout and the sprinkler system is not otherwise required by Section 506 (area) or Section 508 (substitute for one- hour). Section 507. Towers, spires and steeples shall comply with Section 507, Exception 1. FIRE-RF.SISTIVE COHS'IRUC'ITOH Where one-hour fire-res'istive construction is required, an approved automatic sprinkler system, when not otherwise required, may be substituted for the one-hour construction. However, the fire sprinkler system shall not waive or reduce fire-resistive requirements for: occupancy separation, exterior walls due to location on property, area separation walls, shaft enclosures,· corridor protection, stair enclosures, corridor protection, stair enclosures, exit passageways, type of construction separation· per .. Section 1701 and atriums constructed in accordance with Section 1715. Section 508. · Provide details of the one-hour fire-resistive construction. Include roof/ceiling assemblies, floor/ceiling assemblies, wall assemblies, post and beam assemblies, etc. Detail how one-hour fire-resistive wall construction is maintained at built-in wall fixtures and behind mailboxes, fire extinguisher cabinets, electric panels exceeding 16 square inches in area, etc. $ection 4304 (e). Detail and reference I.C.B.O. number or other approval for horizontal fire assembly using trusses. Item 21-1.1 in-Table 43-C requires 2 layers of 5/811 Type X gypsum wallboard at the bottom chords of trusses. Section 4303 (b) 8. Detail how fire-resistive wall and ceiling protection ·will be maintained at all duct penetrations such as at bathroom and kitchen hood fans, laundry room fans and dryer vents. Also detail recessed light fixtures. Show duct openings in ceilings, regardless of size, have approved ceiling fire dampers. Section 4303 (b) 6. See..-be-fc,c.v- I I e,w,{ l o2 -Pn:? v,d( I focc::,,f(an ef t'YlP 5 !I (,, ' ::-,1 ' ,- n/ ® -:,_ -.'~ ... '~ Roof/ceiling and floor/ceiling assemblies must be of one-hour construction. Detail fire assemblies on plans along with their ICBO number or other I.D. number from the Fire-Resistive Design Manual published by the Gypsum Assoc. or U.L. number or item number from Table 43-C._ UBC. wf.L-re. ~ ~ '? Detail water hea~ents located inside fire- resistive wall construction or within fire- resistive shafts. Section 1706 (a). r-,4) Clearly identify location and hourly fire-1.....::i' resistive rating of vertical shaft's on the plans. Provide construction details showing location of fite dampers and ho~ fire resistivity will be maintained at floors and roofs. Se,ction 1706. Tiu... p(PW1$ .sf,// show- ''ho/L€>'1 J.Ptf'/~ t,tp fhrt::>~h ffi£ .Pf~,::,rS. 15. ·Detail column fire protection per Table 43-A in / the UBC and specify column impact protection in garage areas per Section 4303 (b) 5. As a minimum, show a 22 ga. steel jacket around each column to a height of 3 feet above the ground for impact protection. I. f· Structural members such as beams supporting m9re than one floor or roof must be individually fire.protected. (Section 4303 (b) 6.) Detail r~quired protection. Clearly specify minimum thickness of walls·and slabs to provide _,..,,....,,,----hour fire-resistive rating per Table 43-B and c. Clearly specify minimum cover for bonded reinforcing at __ fire-rated floors, _____ .fire rate~ columns, -,-,,_ ____ fire rated beams. Clearly .specify minimum cover for prestressed concrete tendons per Section 4303 (c) 3. Detail all plumbing ang electrical penetrations at occupancy, area, corridor or other fire separation walls as specified in Section 4304 (e). Detail all furred ceilings as required in Section 4203. Show fire-retardant treated wood ~here necessary. Clearly label and identify on the plans the fire-resistive corridors, area separation walls, shafts, occupancy . separation walls and floors, exit courts less than 10 feet wide and exit enclosures, along with their hourly ratings. Section 302 (a). IN'IERIOR WALL ARD CEILIHG FINISH Foam·plastics shall not be used as interior finish except as provided in Section 1712. 2/14/90 f· J. s/ t· · When walls and ceiling are required to ba fire-resistive or noncombustible, the finish material shall be applied directly against such fire-resistive or noncombustible construction or to furring strips not exceeding 1-3/4 inches. The furred space shall be filled with inorganic or Class I material or fire stopped not to exceed 8 feet in any direction. Section 4203, 1. When finish materials are set out or dropped more than 1-3/4 inches from fire-rated walls or ceilings the finish material shall be Class I or sprinklered on both sides or attached to noncombustible backing or furring strips. Section 4203, 2. Hangers and assembly members of dropped ceilings below a one-hour ceiling assembly shall be noncombustible materials except in -Types III and V construction, where fire- retardant treated wood may be used. Section 4203, 2. ·All interior wall or ceiling finishes less than 1/4 inch thick shall be applied directly against a noncombustible backing unless it is, in accordance with an approved tested assembly. Section 4203, 4. Provide a note on the plans or on the finish schedule, "Wall and ceiling materials shall not exceed the flame spread classifications in UBC Table 42-B.11 · -t... ,e-vr~ ~. :c e:>="'PC(,YIC:f. OCCUPANCY SEPARATION A_. -hour occupancy separation is required between ___ occupancy and the _·_occupancy. Table 5-B, Section 503 (d), Tables 43-A, B, C and Chapter 43. (See exceptions in Section 503) Administrative and clerical offices and ·similar rooms need not be separated from other occupancies provided they are less than 25 percent of the floor area of the major use and not related to· -an H-2 or H-3 occupancy-.--··· - Section 503 (a). Provide _ _,..._-hour fire-resistive door assemblies in the -...,,,.,=--hour occupancy separation. Section 503 (c). 6 ,'11 ,, .,, . 9/1· A B-1 occupancy in the basement or first story of a building housing a group B, Division 2 occupancy may be classed as a separate building. The building above · may also be considered·a separate and distinct building for the·purpose of area limitation, limitation of number of stories and type of construction ONLY if the conditions of Section 702 are met: a. B-1 is Type I construction. b. B-1/B-2 is separated by a three-hour occupancy separation. c. B-1 is restricted to passenger vehicle storage, entry lobbies, laundry rooms and mechanical equipment rooms (no storage, recreation ro.om, etc.). d. The maximum building height does not exceed the limits in Table 5-D for the least type of construction. The Type I construction is required to have protected openings when located within 20 feet from a property line or centerline of a public way. Section 1803 (b). In Type I ·construction, no openings are permitted in exterior walls less than 5 feet from a property line. Section 1803 (b). All openings in floors forming a three-hour separation shall be protected PY vertical enclosures above and below the opening. The· walls of such enclosures shall be not less than two-hour fire-resistive. construction, and openings therein shall· be protected by a one · and one-half-hour assembly. Section 503 (c) 2. Tables 43-A, B, C and Chapter 43. Structural members suppo~ting an occupancy separation must have the same fire-resistive rating as the separation. Section 503 (b). No openings are·allowed in a four-hour fire~ resistive occupancy separation wall. Section 503 (c). Openings in a three-hour separation shall be protected assembly, and openings may percent of the length of wall no single opening shall exceed Section 503 (c). fire-resistive by a three-:-hour not exceed 25 in the story and 120 sq. ft. A two-hour fire-resistive separation shall be not less .than two-hour fire-resistive construction. Openings shall be protected by a one and one-half-hour assembly. Section 503 (c). 2/14/90 ~- r· A one-hour fire-resistive separation shall be not less than one-hour fire-resistive construction. Openings shall be protected by a one-hour assembly. Section 503 (c). Occupancy separation wall penetrations must be either ferrous or copper and fire-stopped. Steel electrical outlet boxes shall not exceed sixteen square inches and further, shall not exceed one hundred square inches per one hundred square feet of wall, may be installed and shall be separated by a horizontal distance of twenty-four inches when on opposite sides of a wall. Section 4304 (e). Clarify that wiring within concealed spaces complies with the Mechanical Code and UBC Section 4305 (e). 1oi •. Ducts penetrating one or two-hour occupancy 7-separation walls must have fire dampers. A fire door is required for three-hour separations. Section 4306 (j) • K. 116. 1~7. Usable space under the first story shall be enclosed.and shall be separated from the non- usable space as. required for one-hour fire- resistive construction and· '.the door to the usable space shall be self-closing, ·of noncombustible construction or solid wood core, not less than 1-3/4 inches in thickness. Section 1703. Show the basis for the rating of the occupancy separation you propose, i.e., Item number in Table 43-A, B, C; Gypsum Fire-Resistive Design Manual; U.L., etc. Unless the entire building is sprinklered, storage areas in excess of 1000 sq. ft. (3000 sq. ft •. if storage area is sprinklered and not otherwise required to be) in connection with sales occupancies shall be separated from public areas by a one-hour fire-resistive occupancy separation. Section 702 (b). In all occupancies, floors above the first story having 10 or more occupants, shall have not less than two exits. Section 3303 (a). In areas where the occupant load exceeds __ , two exits are required. See _______ _ Table 33-A. ---- Rooms with more than 10 occupants may have~ exit through~ adjoining room. Revise exits to comply. Section 3303(e). Exits should have a minimum separation of one- half the maximum overall diagonal dimension of the building or area served. Section 3303 (c). ,7 .I ! The maximum number of required exits and their required separation must be maintained until egress is provided from the structure. Section 3303 (a). Where a required exit enters a yard or court the minimum width of the yard or court shall be 4411 and the yard must be ·unobstructed and.lead to a public way. Section 3311 (b), Section 3301 (b). Where required exits enter an exit court (see definition, Section 404 and 3301), the exit court must discharge into a public way or exit passageway. The exits from the exit court shall comply with Section 3311 (d) requirements for width, number, and protection of walls and openings when the occupant load exceeds 9. Change in width in a exit court shall.be effected gradually by a guardrail at least 36 inches high and making an angle of not more than 30 degrees with the axis of-the court. Section 3311 (b}. Walls of exit passageways shall be without openings except exits and shall have walls, floors and ceilings of the same fire- resistance required for the building, with a minimum one-hour fire-resistive construction. E;xit openings in the walls shall be protected by a three-fourths-hour assembly. Section 3312 (a). Basements require two exits. Section 3303 (a). Total width of exits in feet shall be not less than total occupant load served divided by 50. Tributary occupant load from basements and stories abpve shall be per Section 3303 (b). and the maximum width required for any story shall be maintained. No point in the building shall be more~-150 feet (200 if sprinklered) from an exterior exit, horizontal exit, enclosed stairway or exit passageway, m8<:!,sured along the path of travel. This may be increased 100 feet if last 150 feet is in a corridor. Section 3303 (d) (See exceptions). Double acting doors __ are not allowed when serving a tributary occupant load of more than 100, or when part of a fire assembly, or part of smoke and draft control assemblies or when equipped with panic hardware. Section 3304 (b). Exit doors should swing in th,e direction of egrees when ·serving an occupant load of 50 or more or when serving any hazardous area. Section 3304 (b). See doors ______ _ 2/14/90 Exit doors should be openable from the inside without the use of a key, special knowledge~ or effort. Section 3304(c) [Note that exit doors serving 10 or less occupants may have a night latch, dead bolt, or security chain per Title 24, 2-3304 (c).] r oc.c...._p, Exit doors from~assembly reems with SO or more ee-cupants shall not be provided with a latch or lock unless it is panic hardware. Section ~-~3o<./, 121.-All doors and gates, within the exit path from 1-an assembly room to a public way, shall not be provided with latches or locks unless they are equipped with panic har?ware. Section 3318. When additional doors are provided for egress purposes, they shall conform to· the width, swing and hardware provisions in Chapter 33. Section 3304(1). Exit doors should be a minimum size of 3 feet by 6 feet 8 inches with a minimum door swing of 90 degrees. Maximum leaf width is 4 feet. Section 3304 (f) and (g). 1i;·Toe net dimension (clear width} at doorways / should be used in determining exit widths required by Section 3303 (b). Section 3304 (f). In consideration of door thicknesses, panic hardware, door swing, etc., the required exit widths have not been furnished. See door 12~- Regardless of occupant load, a floor or landing not more than 1 inch (1/2-inch if disabled access is required) below the threshold is required on each side of an exit door. Section 3304 (i). When a door landing serves an occupant load of SO ·or more, doors in any position shall not reduce the landing dimension to less than one half its required width. Section 3304 (j). Door landings shall have a length measured in the direction of travel of not less than 44 inches. Section 3304 (j). Doors should not project more than 7 inches into the required corridor width when fully opened, nor more than one-half of the required corridor width when in any position. Section 3305 (d). Revolving, sliding and overhead doors are not permitted as exit doors if the .occupant load exceeds 9 or the exit door serves a hazardous area. Section 3304 (h). 8 ., :.._ L. lr- Ramps required by Table 33-A shall not exceed 1:12; other exit ramps 1:8. Ramps steeper than 1:15 shall have handrails as required for stairways. Minimum size _landings and landing clearances must be provided •. section-3307. STAIRWAYS Stairway width must be at least 44 inches when serving-50 or more occupants; 36 inches when less than 50. Section 3306 (b). 1-/2. Eighty inch minimum headroom clearance for / stairways should be indicated on the plans. Section 3306 (p). Note that this is from a plane tangent to the stairway tread nosing. lj.3 •. Stairway handrails should not project more than ( 3-1/2 inches into the required width. Trim and· stringers may not project more than 1-1/2 inches. Section 3306 (b). Enclosed usable space under interior or exterior stairways should be protected on the enclosed side as required for one-hour fire- resistive construction. Show 2 x @ 1611 o.c. nailers. Section 3306 (m) (n). .13i. Landings should not be reduced in width more / than · 7 inches by a door when fuUy open. Section 3304 (j). Stairways from upper levels which extend below the level from which egress from the building is provided, shall have an approved barrier to preclude exiting into such lower levels. Section 3306 (h) & 3309 (e). Vertical qistances between stairway landings are limited to 12 feet. Section 3306 (i). All interior stairways and ·ramps shall be enclosed.· In other .than Hand I occupancies, an enclosure is not required.if serving only one adjacent floor and not connected to stairs or corridors serving other floors. Section ·3309 (a). Stairway riser···must be 4 inches minimum. and 7 inches maximum and minimum run shall be 11 inches. Section 3306 (c). See the exception for private stairways serving less than 10 occupants. · Winding and· spiral stalrways are permitted only in residential occupancies. Section 3306 (d). 2/14/90 10.. Stairways should be enclosed as specified in ( · Section 3309: a. Two-hour fire-resistive walls are required in buildings of Type I and II-F.R. construction, and in all buildings over four stories, and one-hour elsewhere. b. Only exit doors are allowed to open into exit enclosures. · c.· Doors should be labeled one and one-half hours or one-hour fire assemblies, and noted that the maximum transmitted temperature end point shall not exceed 450 degrees (F) above ambient at the end of 30 minutes of the fire· exposure specified in UBC Standard 43-2. d. Exit enclosures should include a corridor on the ground floor extending to the exterior (see exception). Fire-resistive construction should be as required for the exit enclosure, including protected openings. Only exit doors are permitted to open into the corridor. e. An approved barrier is required at the ground .. floor to prevent · people from accidentally continuing to ~e lower level. f. Usable space is not allowed under the stairs. l('· .Occupied floors more than 75 feet above the highest grade should have all exits from the building in smoke-proof enclosures. Section 3310 (b). /43_ In buildings four or more stories, one 1 stairway must extend to the roof. Section 3306 (o). It must be in a smoke-proof enclosure in buildings over 75 feet in height. ·A first story as allowed by Section 702 shall be included in determining the number of stpries when determining if a stairway to the roof is required. Section 3306 (o). 9 ·,. ' ... ·.· ' Handrails: Handrails .are required on eacq side of stairways. Stairways less than 4411 wide or stairways serving one dwelling unit may have one handrail (if not open on both sides). · b. Private stairways (1 tenant) need only have a handrail on one side if 3011 or less in height. c. Handrails shall be 3411 to 3811 above nosing of treads and be continuous. d. Except fQr private stairways, a~ least one rail shall extend 611 beyond top and bottom risers. e. All stairs· shall have handrails terminating in a newel or safety post. Section 3306 (j) . Note: Where access for the disabled is necessary, Title 24 requires handrails on both, sides to extend 12 inches beyond the top nosing and 12 inches plus the tread width beyond the bottom nosing. Additionally, handrail height should then be changed to 3011-3411 • The handgrip portion of all handrails shall be not less than 1-1/2 inches nor more than 2 inches in cross-sectional dimension. Handrails projecting from walls shall have at least 1-1)2 inches between the wall and the handrail. Section 3306 (j). Openings in the exterior wall below or within 10 feet horizontally of an exterior exit stairway in buildings over two stories shall be protected by a self-closing assembly having a three-four~s-hour rating, unless two separate exterior stairways serve an exterior exit balcony. Section 3306 (1). 1,7. Openings in exterior walls below or within 10 . feet, measured horizontally, of an exterior ···--stair shall be protected by self-closing fire assemblies having a three-fourths-hour fire protection rating when the stair serves a floor level having openings in two' or more floors below it. See exception above. Section 3306 (1). 14s. Buildings four or more stories in height shall f have a stairway numbering system complying with Section 3306 (q). M. 14~- CORRIDORS Corridors and exterior exit balconies serving 10 or more occupants must be a mininrum 44 inches wide and 7 _feet high to the lowest projection. Section 3·305 (b). 5/10/90 When a corridor or exterior exit balcony is accessible to the handicapped, changes in elevation shall be made by means of a ramp. Section 3305 (f). Corridors serving 30 or more occupants shall have walls and ceilings of one-hour construction except: a. Corridors greater than 30 feet wide when the occupants have an exit independent from the corridor. b. Exterior sides of exterior exit balconies. c. Corridor walls and ~eilings need not be of fire-resistive construction within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sprinkler system throughout and smoke detectors are installed within the corridor in accordance with their listing. Section 3305 (g). Exit corridors shall not be interrupted by intervening rooms. Foyers, lobbies Qr reception rooms constructed as for corridors shall not be construed as intervening rooms. Section 3305(a), One-hour fire-rated corridors shall have door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes, except openings in interior walls of exterior exit balconies. Doors shall be maintained self-closing or be automatic-closing by action of a smoke detector per Section 4306 (b). Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 3305 (h). Total area of all openings, except doors, in any-portion of an interior corridor, shall not exceed 25 percent of the area of the corridor wall of the room which it is separating from the corridor. Such openings shall be protected by fixed, approved 1/4 inch thick wired glass installed in steel frames. Section 3305 (h). ts._ Elevators serving more than two stories shall not open into required one-hour exit corridors unless protected by an approved smoke/draft control door system. In high rise buildings refer to Section 1807 (h). Section 3305. Duct penetrations of fire-rated corridor walls and. ceilings shall have fire dampers per Section 4306 (j). 10 N. (§ One-hour corridors shall not be used as an integral part of a duct system. This includes the space above a dropped ceiling within the one-hour corridor. UMC Section 706 (b). Provide a complete architectural section of the corridor, and exterior exit balcony, showing all fire-resistive materials and details of construction for all floor, walls, roof and all penetrations. Section 3305 (g). Ceilings of combustible materials cannot be suspended below the one-hour corridor ceiling. In types III or V construction·fire retardant treated wood may be used. Section 3305 (g). Corridor walls may terminate at the ceiling only if the ceiling is an element of a one- hour fire-resistive floor or roof system. Section 3305 (g). · When two exits are required, dead end corridors and exit balconies are limited to 20 feet. Section 3305 (e). If a room with an exhaust "fan has a door opening into a rated corridor, show how make- up air will be provided to the room. The door cannot be undercut, nor can a louver in·the _door be provided. Section 3305(h)l. EXIT SIGNS Exit signs are r~quired since the occupant load exceeds fifty. Show all required exit sign locations. Section 3314 (a). '16~ Show two sources of power for the lamps at exit ~ signs. Section 3314( d). @show that exits are lighted with at least a one foot candle at floor level, o.M.&{ Xf· -:source. o.P Section 3313 (a). fttJi,ve.r) F· Se-c, "33(3, Cb). 16A. Show separate sources ,of power for exit f illumination. (Occupant load exceeds 100) Section 3313 (b). The exit sign ade·quate·. ELEVAl'ORS locations as shown are not Elevators shall be enclosed in a one-hour shaft except in Type I and Type II F.R •. construction where the elevator shall be in a -two hour shaft. Section 1706. Every opening into an elevator shaft enclosure shall be protected by a self-closing fire assembly having a one-hour fire rating in one- hour shafts and one and one-half hours in two hour shafts. Section 1706. 2/14/90 171 Elevator shafts extending through more than two floor levels shall be vented to the outside. The area of vent shall be not less than 3 1/2% of the shaft area and a minimum of 3 square feet per elevator. Section 5104. Elevators in high rise buildings shall comply with Section 1807(b). Every elevator lobby or entrance area shall be provided with an approved smoke detector as required by Section.5103(b). 1f3. Revise the number hoistway enclosure 5103(a). of elevator cars per to comply with Section P. Provide clear inside as required by U.B.C. Title 24 2-5103(d.1). elevator Section car dimensions 5103(d) 6 and a. At least one elevator in buildings 4 or more stories in height: 8011 by 5411 , with a 42-inch side slide door. Applies only to: high-rise buildings, A/E/I occupancies, State-owned buildings, residential care homes, hotels, motels, apartments and cond~miniums. b. Elevator in buildings more than two stories or buildings where disabled access is required to upper level(s): 6811 by 5411 , with a minimum clear door width of 3611 • c. Elevators other than in (b) above serving less than 50 occupants shall have a ·minimum inside platform of 4 feet 6 inches by 4 feet 6 inches and a minimum clear door width of 36 inches. Provide notes, details or specifications to show the elevator will comply with UBC Sections 5102-5106 and Title 24 Section 2-5102 through 2-5105. DQors other than the hoistway door and the elevator car door are prohibited at the point of access to elevator car, except doors readily openable from the car side. Section 5106. GLASS AND GLAZING Specify on ·the window schedule the glass type and thickness to show compliance with Table 54-A and B. Glazing, in the same wall plane as a door, must be safety glazing if within 1211 of the door and less than 6011 above the walking surface, unless the glazing is leaded or faceted glass. Section 5406 (d) 6. 11 17{. Glass in excess of 9 sq. ft. with the lowest edge less the 18 inches above a walking surface shall be safety glazing or shall have a· horizontal member not less than 1-1/2 inches in width .ind lQcated between 24 and 36 inches above the walking surface. Section 5406 (d) 7. Q. 18f- 18f-11. lt- ~- A Class 32-A. roof covering is required. Table Specify roof pitch. Roof pitch is not adequate for roof covering specified. Specify minimum pitc~ of ____ _ Specify rpof material and application. Chapter 32. . 1~. Specify ICBO, UL or other recognized listing appre>val number for roof materials not c·overed in UBC, e.g., tile, etc. ·18,. Specify minimum 1/4 inch per foot roof slope for drainage or design to support accumulated water. Section 3207 (a) and Section 2305.(f), Show roof drains and overflows. Size drains per Appendix D of UPC, Section 3207 (a). Show the legal basis to allow roof drainage to flow onto the adjacent property. B-2 and B-4 occupancies with over 50,000 sq. ft. of undivided area and H-1,2,3,4 or 5 occupancies over 15,000 sq. ft. of single floor area· shall have smoke and heat vents per Section 3206. i9. Plastic skylights must be separated from each i other by at least 4 feet. Section 5207 (a) 6. 110. Plastic skylights shall not be installed within that portion of a roof located within a distance to property line where openings in exterior walls are prohibited or required to be -i)Iotected. · .Section 5207 (a) 7. 19l. Provide-skylight details to show compliance I ·with Chapter 34 and Section 5207 or provide ICBO-or other recognized approval listing. Provide plastic roof panel details to show compliance with Section ·5206 or provide ICBO or other recognized approval listing. Show attic ventilation. Minimum vent area is 1/150 of attic area or 1/300 of attic area if at least 50 percent of the required vent is at least 3 feet above eave or cornice vents. Section 3205 (c). 2/14/90 1~- Provide a minimum 2211 x 3011 attic access opening (or 3011 x 3011 if equipment is in attic). Section 3205 (c). FIRE EX:rINGUISBIHG Fire sprinklers are required for any story or basement when the floor area exceeds 1,500 sq. ft. and there is not provided at least 20 sq. ft. of opening entirely above the adjoining ground in each 50 lineal feet or fraction thereof of exterior wall on at least one side, or when openings are provided on only one side and the opposite side is more than 75 feet away. Section 3802 {b). Fire sprinklers are required in a basement if any portion of a basement is more than 75 feet from openings in an exterior wall. Section 3802 (b). Fire sprinklers are required at the top of rubbish and linen chutes and in their terminal rooms. Chutes extending through three or more floor shall have additional sprinkler heads installed within such chutes at alternate floors. Sprinkler heads shall be accessible for servicing. Section 3802 (b). Fi~e sprinklers are required in retail sales rooms where the floor area exceeds 12,000 sq. ft. on any floor or 24,000 sq. ft. "on all floors or in B-2 retail sales occupancies more than three stories in height. Section 3802. Fire sprinklers are required in H occ~pancies when exceeding the areas in Section 3802 (f). Provide fire sprinklers in rooms used by the occupants for the consumption of alcoholic beverages when the total area of unseparated rooms exceeds 5000 square feet. For uses to be considered as separated, a one-hour occupancy separation is required. Section 3802 (c). Provide fire sprinklers----,------- Section 506, 507, 508 or 3802. jurisdiction ordinance. See also Note on the plans: "When serving more than 100 sprinkler heads, automatic sprinkler systems shall be supervised by an approved central, proprietary or remote, station service, or shall be provided with a local alarm which will give an audible signal at a constantly atf.ende.4. location." Section 3803. 12 s. Provide class_ standpipes per, Section 3807. A first story as allowed by Section 702 shall be included in determining the number of stories, when determining if standpipes are required. Section 3806. Provide a copy of the project s~il report prepared by a califomia licensed architect or civil engineer. The report ·shall include foundation design reco11111endations based on the engineer's findings and shall comply with UBC Section 2905. Specify on the· foundation plan or structural specifications sheet .the soil classification, the soils expansion index and the design bearing capacity of the foundation. Section 2905(c). Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the reco11111endations in the soil report are properly incorporated into the plans. (When required by the soil report). The foundation plan does not comply with the following soil report reco11111endation(s) for this project _______________ _ Provide notes on the foundation plM listing the soils report reco11DI1endations for foundation slab and building pad preparation. 2r~-The soils engineer reco11111ended that he/she review.the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: l. The building pad was prepared in accordance with the soils report, 2. The. utility trenches have been properly backfilled and compacted, and 3~ The foundation excavations comply with the intent of the soils report". Provide spread footings for· concentrated loads designed for 1,000 psf soil bearing or per bearing value as determined by an .engineer or architect. Chapter 29. Show height of all foundation walls. 23. Chapter 2f2· Show height of retained earth on all foundation l walls. Chapter 23. 2/14/90 Show distance from foundation to edge of cut or fill slopes and show slope and heights o~ cuts and fills. Chapter 29. Note on the plans that wood shall be 6 inches above finish grade. Section 2907(a). Note on plans that surface water will drain away from building and show drainage pattern and key elevations. Section 2905 (f). Dimension foundations per.Table 29-A. loors Thickness of Supported* Stemwall Width Depth Footing 1 611 1211 1211 • 611 2 811 1511 1811 711 3 1011 1811 2411 811 *Foundations may support a roof in addition to the floors. Where only a roof is supported, use foundation for one floor. For buildings adjacent to slopes steeper than 3:1, note.on the plans:_ "On graded sites, the top of any exterior foundation shall extend above the elevations of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus 2 percent." Provide elevations on the site plan to show compliance. Section 2907'(d) 5. Show foundation sills to be pressure treated, or equal. Section 2516 (c) 3. Show foundation bolt size and spacing. Foundation bolt size and spacing for shear walls must be clearly shown on the foundation plan. Section 2907 (e). 22,. Specify size, ICBO number and manufacturer of power driven pins. Show edge and end distance and spacing. Section 306 (f). 22A. Show size, embedment and location of hold down anchors on foundation plan. Section 2303(b) 4. 2J2 •. Note on the plans that hold down anchors must 7· be tied in place prior to foundation inspection. Show adequate footings under all bearing walls and shear walls. Section 2907 (b). Show stepped footings for slopes steeper than 1:10. Section 2907 (c). Show m1nimum ·18 inch clearance from grade to bottom of floor. r joists and minimum 12 inch clearance to bottom of girders. Section 2516 (c) 2. Show pier size, undisturbed soil. spacing and Table 29-A. depth into 13 ,. : ,~ ' '· \·; T. u. f Show minimum under floor access of 18 inches by 24 inches. Section 2516 (c) 2. Show minimum under floor ventilation equal to a 1 sq. ft. for each 150 sq. ft. of under floor area. Openings shall be as close to corners as practicable and shall provide cross ventila~ion on at least two approximately opposite sides. Section 2516 (c) 6. MASONRY Show veneer support and connections in Seismic Zones 3 and 4, comply with Section 3002, 4, 5, 6 and Section 2515 (a) regarding ties and #9 wire in horizontal joints. Show height and construction details of all masonry walls. Chapter 24. Show floor and roof connections to masonry walls. Connection shall resist 200 .pounds per lineal foot or the actual ·design load, whichever is greate~. Cross grain tension or bending in wood ledgers is not permitted. Section 2310. Provide details for damp proofing the foundation walls, below finish grade~ where usable space exists on the interior side of the walls. Section 1707 (d). Show a minimum 211 air space and flashing between planter-and building walls.. Section 2516 (c) 7. FRAMING Provide complete structural details on the plans with cross referencing as needed to show the -structural framing will comply with the design calculations and building code requirements. Provide .minimum structural specifications on the plans to show that all structural materials will comply with the design calculations and building._code requirements. 2/14/90 On the cover sheet of the plans,. specify any items requiring special inspection, in a· format similar to that shown below or sticky back. REQUIRED SPECIAL INSPECTIONS . In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 306 of the Uniform Building Code. ITEM REQ. IF CHECKED SOILS COMPLIANCE PRIOR TO FOUNDATION INSP. STRUCTURAL CONCRETE OVER 2500 PSI PRESTRESSED STEEL FIELD WELDING HIGH STRENGTH BOLTS EXPANSION ANCHORS SPECIAL MASONRY SfRAYED ON FIRE PROOFING PILES/CAISSONS DESIGNER-SPECIFIED OTHER REMARKS Where special inspection is required for masonry, note on the plans that prism tests shall be performed in accordance with Section 2405. Section 2406(c)l. Show wall bracing. Every exterior wood stud wall and main cross partition shall be braced at each end and at least eyery 25 .. feet of length with 1 x 4 diagonal let-in braces or equivalent. Section 2517 (g) 3. Note cross bridging or blocking. Floor joists and rafters 1211 or more in depth shall be supported laterally by bridging at intervals not exceeding 8 feet, unless both edges are held in line. Section 2506(h), 2517. Show blocking at end and at supports of floor joists, and· for. raftets · at exterior walls. Section· 2517 (d) 3. 24~-Show solid blocking at ridge line and at \ exterior walls on trussed roofs. Section 2506 (h), Section 2517 (h). 14 ., ,, ,_ ,- i• 24~. 25p. Bearing partitions, perpendicular to joists, shall not be offset from supporting girders, beams, walls or partitions, more than the depth of the joists. Section 2517 (d) 5. Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center and be just above the ceiling joists, where rafters and ceiling joists are not parallel. Section 2517 (h) 4. Show rafter purlin braces to be not less than 45 degrees to the horizontal. Section 2517(h)5. Show 1/211 minimum ~learance between top plate of interior -partitions and bottom chord of trusses. (To ensure loading will be as designed). Show or note fire stops at the following locations per Section 2516 (f): a. b. c. in concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10 foot intervals along the length of the wall. at all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings; in concealed spaces between stair stringers at the top and bottom· of the run and· between stud's along and in line with the run of stairs if the walls under the stairs are unfinished; and d. in· openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials. In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the_ ceiling and floor above so that no concealed -space exceeds 1,000 s.f. and· no horizontal dimension exceeds 60 L.F. (if space has sprinklers, ~then 3,000 s.f. and 100 L.F.). Section 2516(f). . .. In buildings having floors and roofs of wood fra,me construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and roof above so that no concealed space exceeds 3,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space .has sprinklers, then 9,000 s.f. and 100 _L.F.). Section 2516(f). Show double top plate with minimum 4811 lap splice. Section 2517 (g) 2. Show nailing will be in compliance with Table 25-Q. 2/14/90 Show stud size and spacing. Maximum allowable stud heights; bearing wall: 2 x 4 and 2 x 6 max. 101 ; non-bearing: 2 x 4 max. 14', 2 x 6 max. 20 1• -Table 25-R-3. Studs supporting two floors, a roof and ceiling must be 3 x 4 or 2 x 6 at 1611 o.c. Table 25-R-3. Note an A.I.T.C. Certificate of Compliance for glued laminated wood members shall be given to the building inspector prior to installation. Section 2505. 2~4. Detail all post to beam and post to footing ) connections and reference the detail to the plan. Section 2516 (m): Detail shear transfer connections, including roof and floor diaphragms, to shear walls. Section 2513. Specify nail size and spacing for all shear walls, floor and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimension ratios. (Tables 25 I, J, K) and Section 4714 (d). Provide truss details and truss calculations for this project. Specify on the plans the truss identification numbers. Provide roof framing plan and floor framing plan. Section 302 (d). Provide framing sections through Section 302 (d). Specify all header sizes for opening over 4 1 wide. Section 2517 (g) 5. Provide calculations for main vertical and horizontal framing members and post footings. Section 302 (d). Provide calculations for lateral loads, shear panels, shear transfer and related. Section 302 (a) 7 • In Seismic Zones 3 and.4, the allowable shear values for drywall in Table 47-I must be reduced 50% for earthquake loading. This does not apply to wind loading. 15 ;, 2J4. Show on the plans all structural requirements l developed in the structural calculations. 2f-Columns and posts located on concrete or masonry floors or decks exposed to the weather or to water splash or in basements and which support permanent structures shall be supported by concrete piers or metal pedestals projecting above floors unless approved wood of natural resistance to decay or treat wood is used. Section 2516 (c) 4. 27~- Individual concrete or masonry piers shall ptoject at least 8 inches above exposed ground unless the columns or posts which they support are of approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. Specify plywood grade and panel identification index. Table 25-S-l. When roof pitch is less than 3:12, ·design ridge as a beam. Section 2517 (h). If foundation cripple wall studs are less than 1411, framing shall be solid blocking or the cripple studs sheathed with plywood. Section 2517 (g) 4. Cripple ~all studs exceeding 4 feet in height shall be 3 inch by 4 inch or 2 .inches by 6 inches when supporting 2 stories. Section 2517 (g) 4. Show plyw_ood sheathing over exposed eaves, or other weather exposed areas, is "bonded with exterior glue." Plywood used for exterior wall covering shall be the exterior type. Section 2516 (g)3, 2516{i). 212. Ridges, hips, and valleys shall be at least one J size larger than supported rafters. Section 2517 (h) 3. 2,3. In·open beam construction, provide strap ties across the beams at the ridge support; Section 2501 (b) •. MISCELI.AHmUS Parking garages ·shall have an unobstructed headroom clearance of not less than 71 -011 above the finish floor to any ceiling, beam, pipe or similar construction. Section 702 {b). . · r:::,":') Provide details of restrooms to ·show c;mpliance ~ with Section 510 (b), regarding floors, walls and showers. ,Se.e..-be,( t:J w--' 276. If both sexes will be employed and the number of employees exceeds four, provide separate toilet facilities for men-and women. If 11both ·sexes will be employed and the total number of employees will not exceed four11, and only one restroom is provided, note· the words i~ quotation above on the floor plan. Section 705 Z.75. A+ Ah-fe ~ I pa:c± H:!. A:--S/pw 5'' . I 3/28/90 w. Show unenclosed floor and roof openings, ope~ and glazed sides of landings and ramps, balconies or porches more than 3011 above grade or floor, and roofs used for other than service to the building have 4211 minimum height guardrail, through which a 611 sphere cannot pass, and designed for 20 lbs. per lin. ft. applied horizontally at top rail {50 lbs. for exit facilities serving more than 50). Section 1711. Table 23-B. Provide platform and stage construction, including occupancy separations and roof vents, as per Chapter 39. Provide at least one 'drinking fountain for each floor level in Group A occupancies. Section 605. Show that aisles and seats comply with Sections 3315 and 3316. Buildings housing Group A Occupancies shall front directly upon or have access to a public street not less than 20 feet in width. The access to the_public street shall be a minimum 20-foot-wide right-of-way, unobstructed and maintained only as access to the public street. The main entrance to the building shall be located on a public street or o~.the access way. Section 603. Pedestrian walkway shall comply with Section 509. Lateral bracing for suspended ceiling must be prqvided. (UBC Table 23-P) Where ceiling is not supporting interior partitions, ceiling bracing shall be provided by four No. 12 gauge wires secured to the main runner within 2 inches of the cross runner intersection and splayed 90 degrees from each other at an angle not exceeding 45 degrees from the plane of the ceiling. A strut (adequate to resist the vertical component from lateral loads) fastened to the main runner shall be extended to and fastened to the structural members of the roof-·-or· ·floor above. These horizontal restraint points shall be placed 12 feet o.c. in both directions with the first point within 6 feet of each wall. Attachment of restraint wires to the structure above shall be adequate for the load imposed. UBC Standard 47-18. TITLE 24 HANDICAPPED ACCESS (.;":::'\ Provide note and details on the plans to show V compliance .. with the enclosed Handicapped Access· Check List. Handicapped access requirements may be more restrictive than the UBC. B- 16 Y. ,~. •. . ENERGY CX>NSERVA:rIOK Provide mechanical plans, plan details, calculations and completed forms to show compliance with .state regulations for energy conservation. Provide electrical plans, 'plan details, calculations and the completed Form· 5 or CF-5 to show compliance with state regulations for energy conservation. Incorporate in the plans or specifications the attached 11Iitle 24 Mandatory Requirements" and the "Title 24 Construction Compliance Statement Requirements11• ADDITIONAL ~.Please see additional corrections, or remarks, 'Jon the following page. ~ Io speed up the recheck process, note on this i_:::.:.; list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation·page, etc. ~ Please indicate here if any changes have been \0 made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describle them and where they are located in the plans. Have changes ·been made to· the plans not resulting from this correction list? Please check. __ ...,...Y.es ____ No NOTE: The following provisions are contained in Title 24, Part 2, California Building Code, as adopted and enforced by the State Fire Marshall. They are ,provided here as a courtesy to assist designers in developing the project documents. All applicable provisions may not necessarily be included. Please direct any questions regarding interpretations of these _provisions t:o ·.the __ '.1,_ocaX.fi;-~ -!>_~p~!:Jlle??-t• sf. Walls of corridors and exterior exit balconies in Groups A,E,I,R-1 and C Occupancies having an occupant load of more than~ pe~sons and in all other occupancies having an occupant load of 30 or more shall be not less than one-hour fire-resistive construction. ·Section 3305(g)l. 3/28/90 C-~Where exit signs are required by Section ~ 3314(a), approved and listed internally,. externally or self-illuminated low-level exit signs complying with Section 3314 shall be required.· The bottom of the sign shall be not less than 6 inches nor more than 8 inches above the floor level. For exit way doors, the sign shall be on the door with the closest edge of the sign with 4 inches of the door frame or adjacent to the door. Such signs shall be of a type which is perceptible to the sense of touch. Section 3314(e). Where exit signs are required by Section 3314(a), all exit corridors shall be provided with continuous low-leyel exit path marking. Approved and listed internally or self- illuminated marking shall be installed at floor level or no higher than 8 inches above the.floor level. Such marking shall be of a type which is perceptible to the sense of touch. Section 3314(f). Area separation walls shall not be considered to create separate buildings for the purpose of automatic fire-sprinkler system requirements as set forth in Chapter 38. Section SOS(e)6. EXCEPITON: Buildings separated by continuous area separation walls of four-hour fire- resistive construction without openings. Buildings required to have automatic fire- sprinkler protection as set forth in Section 13113 of the Health and Safety Code (homes for ·children or the aged) are prohibited from using area separation walls in lieu of automatic fire-sprinkler protection. In educational occupancies, storage and janitor closets shall be of one-hour fire- res'istive construction with openings protected by assemblies having at least a three-fourths- hour fire-resistive rating. Section 802(c). Section 1807 should be reviewed for all high- rise buildings. The exception in Section 3318 of the UBC has been revised so as to allow··the omission of panic hardware at the main exit in churches (by using signage), only when the occupant load of the church is less than 300. ~ If emergency warning systems are required, '(::.,J they shall activate a means of warning the he?-ring impaired. Flashing visual warnings shall have a frequency of not more than 60 flashes per minute. Section 7204. 17 The jurisdiction has. contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, california 92123; telephone number of 619/560-1468, ·to perform the plan check for your project. If you have any questions·regarding these plan check items, please contact __ ..,~....,ll:at: ..... J_,G.__...,h.,._1/?f:...,._ ___ _ at Esgil Corporation. Thank you. Enclosures: · 1. 2. 3. 3/28/90 @ 1he-/n-5~*9, -s/211/u(,d {(~I './y the-: l-br2u);n ritr«ze-:fr~n n e feel eo~ ~fcu cld v..J/zue ver d 1 'PR-o:.-17 t-'iJ/ee; tP ,r &115 frur.,iitea Cl.bl/./, 18 3 Mern 5 /1 1"! s~c .. IOO~Cb 3 3 /(}, 3 1. 3fz,· TITLE 24 HANDICAPPED ACCESS CORRECTION LIST Jurisdiction Co.dst?ad _________ __....__. ____ +-1 ------- Plan Check No. 9 /-'['8ca ----'..a...-'---";..;;;.;__ ___ _ References to section numbers with prefix 11211 are to Title 24, California Code of Regulations, Part 2 (California Building Code). Prefix 11311 is for Part 3 {California Electrical Code). Prefix "S" is for Part S (California Plumbing Code). Exemptions claimed for any item shal1 be requested in writing and shall include all data needed to determine "unreasonable hardship" as described in Section 2-422. SITE DEVELOPMENT !~ HANDICAPPED PARKING SPACES a. Provide . ....,.. _____ handicapped spaces. 2-7102(b) b. Space shall be so located that handicapped persons are not compelled to wheel or walk behind parked cars other than his/her own. 2-7102(c) c. Parking space shall be a minimum of 9 ft.xl8 ft. with adjacent marked S ft. loading zone. Double space shall be 23 ft. wide. Where a single space is provided, the loading/unloading zone s~ll be on the passenger side of the vehicle.· 2-7102(c). d. Maximum slope of parking surface in any direction shall not exceed 1/411 per .foot.. 2-7102(e). e. Parking space(s) shall be identified with the International Symbol of Accessibility on reflectorized sign affixed to post or wall, and ~ duplicated on parking surface (symbol to be 3611x3611 and painted at the back of the parking stall). 2-7102(f) f. Entrance to parking area ( or at. each stall) shall have a sign stating that unauthorized -vehicle(s) parkipg in handicapped space(s) may be subject to tow-away. 2-7102(£) g. If covered parking is. provided, then a reasonable portion of the total numb~r of stalls reserved for the disabled shall also .be covered. 2-7102(a) . ,. h. Entrances to and vertical clearances within-accessible levels of parking structures shall be 8 ft. 2 in. to any structural member, duct or pipe. 2-7102(g) f. CURB RAMPS a. Curb ramps shall be located wherever pedestrian path crosses curb. (2~ 7103(a)) · b;·-Curb ramp shall be 4811 min. width (2- 7103(b)) with maximum slope of 1 in 12. 2-7103(d) c. A level 4811 min. depth landing is required at top of curb ~amps over entire curb ramp width. 2-7103(d) I· d. If no landing is provided, the slope of flared sides shall not exceed 1 in 12. 2-7103(d) e. Surface is to be slip contrasting finish sidewalk. 2-7103(f) resistant and a from adjacent f. Border markings shall be 1211 wide of l/411xl/411 grooves, 3/411 apart, located at top an,d sides. 2-7103(h) WALKS a. Site development and grading .shall·be designed to provide access to primary entrances and access to normal paths· of travel and where necessary to provide access shall incorporate pedestrian ramps, curb ramps, etc. 2-710l(a) b.· Walks sloping greater than 5% (1 in 20) must comply with ramp requirements of Sec. 2-3307. 2-3325(c) c. Walk width shall be 4811 minimum, and shall have slip-resistant surfaces. 2-332S(a) d. The maximum cross slope shall not exceed 1/4'' per foot. 2-3325(a)3 e. Gratings possible. are not 2-3325(b) allowed whenever f. At each gate or door a 6011x6011 level area is required when the gate swings toward the walk. 2-3325(e) g. A 4811x4411 deep level area is required when the gate swings away from the walk. 2-3325(e) · h. A 2411 clear space is required at strike ·side.of gate or door. 2-3325(e) r PEDESTRIAN RAMPS a. A path of travel with a slope greater than 1 in 20 shall be considered a ramp. 2-3307(a) b. The maximum slope shall be 1 in 12. 2-3307(c.l) c. The width shall be 48" minimum. A minimum width of 6011 is required where a ramp serves as a primary entrance to buildings having an occupant load of 300 or more. Group R Occupancies may be 3611 when the occupant load is 50 or less. 2- 3307(b.l) r d. Toe surface of ramps resistant. 2·-3307 (g) shall be slip- e. A 6011 intermediate landing is required at maximum elevation change of 3011 and 7211 landing at each change of direction (over 30 degrees). 2-3307(d.l) f. Landings_are required at top·and bottom of ramps. 2-3307{d.l) g. Bottom landing shall -be minimum of 7211 in the direction.of travel. Fig. 2-33- llA h. Top landing shall be 6011 x 6011 minimum. 2-3307(d.l) i •. When· door swings onto top landi~g, minimum depth of landing required is door width plus 4211 , 2-,3307(d.l.) j. Top landing shall have 6011 min. width when door swings onto the landing, with 2411 on strike side of door at exterior ramp, or 1811 at interior ramp. 2-3307(d.l,) k. Ramp handrails are required on each side of ramp, when slope exceeds l in 15.· 2- 3307(e.l) 1. Ramp handrails s~ll be continuous, located 3011-3411 in height above ramp surface, with 1211 extensions beyond top and bottom, and the ends returned. 2-3307(e.l) m. Handrails shall be 1-1/411 to 211 cross section, spaced minimum of 1-1/211 from wall. 2-3307(e.l) n. A 211 high curb or wheel guide rail centered 311 ± 111 above ramp surface is required on both sides where not otherwise bounded by walls when the ramp exceeds 10 feet in length. 2-3307{h.l) SPECIAL ACCESS LIFTS a. Lifts may be provided between levels, in lieu of elevator, when the vertical distance between landings, structural elevator, structural· -design and·. scµeguards are as allowed by the State of Califomia, Department of Industrial Relations,. Division of Occupational Safety and Heal.th. 2-5107(a) . b. Toe lift platform shall be of sufficient size to accommodate a wheelchair {3011x4811 ). 2-5107(a) c. There shall be a level and clear floor area or landing (6011x6011 ) at each levei for access to-the lift. 2-5107(a) f HAZARDS a. Provide 8011 headroom from walkway surface to any overhanging obstruction. 2:.3326{b) b. Headroom of maintained for etc. 2-522-(f) 801.. minimum shall be walks, corridors, aisles, c. Protruding objects with leading edges between 2711 and 8011 above finished floor shall not protrude more than 411 into walks, corridors, etc. 2-522(f) d. Free standing objects mounted on posts between 2711 and 8011 above the floor may project a maximum of 1211 • 2-522(f) e. Abrupt changes in level exceeding 411 adjacent to walks, except between walks and adjacent streets or drives, shall be identified by 611 high waming curbs above walk surface. 2-3326(a) ~ AHD CIRClJLATIOH 0 ENTRANCES, DOORS, VESTIBULES AND CORRIDORS :.1. All primary entrances to buildings shall 7· be accessible to·the handicapped. 2-330l(f) c) All required passage doors shall. have 3211 clear opening at 90 degrees (3611 door). 2-3304(f) "-e,,u.,,-clot?r ~ ':; ~At least one of a pair of doors shall ~ meet the minimum 3211 clear entrance width requirement. 2-3304(f) Cne.w-d..oo:>r~j I· Threshold shall be no higher than 1/211 above the floor. Edge to be beveled with a slope no greater than 1 in 2, if more than 1/411 • 3304{i.l) e'. Exterior level landing may slope up to { 1/411 per. foot in any direction for surface drainage. 2-413 (9 Door hardware shall be of the lever or push type, mounted 3011 to 4411 above-the floor and-·be operable with a maximum- effort of 8.5 lbs. for exterior doors and 5 lbs. for interior doors. 2-3304{c), 2- 3304(i.2) /1,:'!Toe lower 1011 of the door shall be of '--Jsmooth, plane surface {no recess or trap) except at automatic and sliding doors. 2-3304{i.3) ffi Building entrance(s) shall be identified lJ by sign with the International Symbol of Accessibility. Show location on plan. Toe symbol shall be a white f~gure on blue background. 2-522(b) f. At turnstile, provide an access gate, 3211 clear width opening, within 30 feet of tumstile. 2-3304(i.4) /• There shall be a clear area on each side of door, 6011 deep in direction of door swing and 4411-deep in opposite direction of door swing. 2-3304(i,l) ¥· Width.of clear area on the swing side of the door shall extend 2411 past strike jamb for exterior doors and 1811 past strike jamb for interior doors. 2-3304(i.l) The space between two consecutive doors (vestibule) shall provide a minimum of 4811 clear depth between the open door and a second closed door.Doors in a series at a vestibule shall swing in the saine.direction, or away from the.space between them.· 2-3304(i.l) For corridors over 200 fe~t long, see special requirements of Sec. 2-3305(b)2. ( FLOORS a. Floors of a given story shall be a common level throughout or shall be connected by pedestrian ramps, passenger elevators, or s pecial. acces·s lifts. 2-522(e) STAIRWAYS NOTE:· Only applies where disabled access is provided or required to other levels. a. Treads shall have -smooth, rounded exposed edges and be slip resistant. 2- 3306(s) b. Nosing shall not project more than 1-1/2 inches past face of the riser below. 2-3306(s) c. Risers shall be suffici~ntly solid. 2-3306(s) d. The upper approach and lower tread of each flight of stairs shall be marked _with.a_ contrasting .colored strip_211• in width. 2-3306(r) e. f. g. On exterior stairs,~ tread shall be marked as noted above. 2-3306(r) Handrails are required on each side of stairway. 2-3306 Handrails shall be located . 3011 to 3411 above nosing,extend 1211 beyond top-riser and 1211 plus tread width beyond bottom nosing and returned to wall/newel post. 2-3306(j .1). h. Handrails shall be 1-1/411 to 211 in gripping cros·s section and 1-1/211 clear of wall. 2-3306(j,l) i. Approved stairway identification signs· shall be located at each floor level in all enclosed stairways in buildings two or more· stories in height. The sign shall identify .tii'e stairway, indicate whether the~e is· roof access, the floor level, and the upper and lower terminus of the· stairway. The information shall be presented using raised Arabic numerals and raised braille symbols which conform to Section 522(b)3. The sign shall be located approximately 5 feet above the floor landing immediately adjacent to the door on the strike side. Signs shall comply with requirements of U.B.C. Standard No. 33-2. f · ELEVATORS a. Provide clear inside elevator car dimensions as required by U.B.C. Section 5103.(~) 6 and Title 24 2-5103(d.l). 1. At lea~t one elevator in buildings 4 or more stories ·in height: 8011 by 54", with a 42-incn -side slide door. Applies only to: high.;,r"ise builqings, A/E/I occupancies, · State-owned buildings, residential care homes, hotels, motels, apartments and condominiums. 2. Elevator in buildings more than two stories or buildings where disabled access is required to upper level(s): 6811 by 54", with a minimum clear door width of 3611 • 3. Elevators other than in {b) above serving less than 50 occupants shall have a minimum inside platform of 4 feet 6 inches by 4 feet 6 inches and a minimum clear door width of 36 inches. b. Raised Braille markings and Arabic numerals are required on control buttons and door jambs. 2-5103(d.l) SANITARY FACILIITFS TOILET FACILITIES ACCESS a. When located on accessible floors, sanitary facilities shall be made accessible to physically handicapped. (2-511._l(a)) b. Doorways shall have 3211· minimum clear opening width. 2-511,1 c. There shall be a .level area with 6011 cl~ depth in the direction of the door swing, and a level area with 4411 clear depth in opposite direction of door swing. 2-511.l(a) 1~. MULTIPLE ACCOMMODATION TOILET FACILITIES a. Provide clear area 6011 diameter x 27 11 high -or clear space 5611 x 63" x 27" high. 2-511,l{a) b. Doors (other than handicap compartment) are not to encroach more than 1211 into above mentioned clear space. 2-511.l(a). c. Provide a 2811 clear space between water closet and fixture or 3211 clear space between water closet and wall. 2-511.l(a) d. A 4811 long clear space is front of water closet. space is required when compartment has a side door. 2-511,l(a) . required in A 6011 clear the toilet e. Water closet compartment door to provide -32" clear width for end entry and 3411 elem:: width fo~ side entry. Door to be self-closing. 2-511.l(a) SINGLE ACCOMMODATION TOILET FACILITIES a. Wat~r closet shall be located 2811 from a fixture or 3211 from a wall. 2-511.l(a) b. Minimum clear space in tr·ont of water closet shall be 48". 2-511,l(a) c. In an existing building, a single accommodation toil~t facility may have a space 3611 Wide X 48 11 long in front of water closet. 2-511.l(a) G GRAB BARS AT WATER CLOSE'! r-One at side 4211 long extending 2411 in front of water closet; one at rear 3611 long centered on water closet; both mounted 3311 above floor. Where a tank.- type toilet is used,. grab bar may be as high as 3611• 2-511.l(a) f Bars shall be 1-1/411 to 1-1/211 in • diameter with 1-1/211 clearance to wall. 2-511.l(a) 'c> Bar fasteners and mounting support shall V be able to withstahd 250 lbs./ft. in bending, shear and tens.ion. 2-511.l(a) · @wATER CLOSE'! /, Height of water closet seat shall be 1711 to 1911 above floor. 5-1502 C9 Controls shail be operable with one hand, and shall not require tight grasping, pinching or twisting of the wrist. 5-1502 ~ Cont~ols for the flush valves shall be U mounted on the wide side of toilet areas, no more than 4411 above the floor. 5-1502 (9 The force required to·activate controls shall be no greater than 5 pounds force. 5-1502 f.· URINALS a. Where urinals are provided, the rim of at least one shall project 1411 from the wall and be located 17" maximum above floor. 5-1503(a) b. The force required to activate the flush valve shall be 5 lbs. maximum and located 4411 maximum above floor. 5-1503(b) c. Provide 3011 x 48" clear floor space for forward approach. 2-511.l{b) G LAVATORIES t. Provide 3011 x 4811 clear floor space for forward approach. Said clear floor space may include knee and toe space under lavatory described below. 2-511.l(b) f-JI G (\0 2-7 de clear space beneath lavatories 29n high by 30" wide by 811 deep at top an 911 high by 3011 w:i,de by 1711 deep at bottom from front of lavatory (toe · space). The maximum counter surface height should be 3411 • 5-1504(a) ~Hot water and drain pipes under Vlavatories shall be insulated. 5-1504(b) /n---iFaucet controls and operating mechanism V(operable with one hand) shall be of the type not requiring tight grasping, pinching or twisting of the wrist (such as lever-operated) and an operating force not exceeding 5 lbs. 5-1504(c) e. If self-closing valves are used, they shall remain open for at least 10 seconds. 5-1504{c) 1/. TOILET ROOM ACCESSORIES a. ·Mirror bottom edge shall ·be located 4011 maximum above floor. 2-511.l(b) b. Toilet tissue dispensers shall be mounted within 1211 from the front edge of toilet seat. 2-511.l(b) c. Operating parts of dispensing and disposal fixtures (towels, waste, coin slots, etc.) shall be within 4011 of floor. 2-511.l(b) ®SANITARY FACILITIES ID~IFICATION a. On doorways leading to sanitary ·facilities the symbols to be provided are 1211 Equilateral triangle for men, 12" diameter circle for women, and 1/411 thick, centered on door, 6011 high and contrasting color. Unisex facilities shall be identified by the circle with the triangle superimposed within the circle. 2-511.l(a) I ., r· BATHING FACILITIES a. One such· facility shall comply when provided for the public, clients or employees. 2-511.l(a) b. Shower compartment shall be 4211 wide, 4811 deep, with a 3611 wide entrance. 2-511.l(a) c. Show on the plans that the handicapped bathing facilities shall conform to requirements of Sec. 2-5lla-9, 5-1505 and 5-1506, i.e., folding seat,.flexible shower hose, etc. ~ .:-. · GENERAL ~ DRINKING FOUNTAIN a. Drinking fountains shall be within alcoves. The alcove shall be not less than 3211 wide by 1811 deep. 2-511.l(c) b. When the enforcing agency determines that it would create an unreasonable hardship to locate the water fountain in an alcove, the water fountain may project into the path of travel, and the path of travel shall be identifiable to ·the blind as follows: (1.) The surface of the path of travel at the water fountain shall be textured so that it is clearly identifiable by a blind person using a cane. ?he minimum textured area shall extend from the wall supporting the water fountain to 1 foot beyond the f~ont edge of the water .fountain and shall extend l foot beyond each side of the water fountain, or (2.) Wing walls shall be provided on each side of the water fountain. The wing walls shall project out from the supporting wall at least as far as the water fountain to within 6 inches of the surface of the path of travel. Also, --·· ·-· -there shall be a miniJmiiiC .. of 32 inches clear between the wing walls. /· c. Note on the plans that drinking fountain shall conform to requirementl;I of Sec. 2-51lc and 5-1507. PUBLIC TELEPHONE a.· Provide space 3011 x 4811 for forward or parallel approach to telephone. 2-511.l(d) b. Note on the plans that public telephone shall conform to requirements of Sec. 2-511.l(d). ELECTRICAL REQUIREMENTS a. 15, 20 and 30 amp receptacle outlets shall be installed not less than 1211 above floor. 3-210-50(e) b. Center of switches shall be·located not less than 3611 nor more than 4811 above the floor. 3-380-8{c) t· +· PLUMBING REQUIREMENTS a. Where kitchenettes are provided at ·employee break rooms, conference areas, cul;ltomer lounges, etc., the faucet controls at kitchen sinks shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist (i.e., use lever- operated, push-type, etc.). If self- closing valves are used, they shall remain open for at least 10 seconds. 5-1508 GROOP A OCCOPAHCY ~ AUDITORIUMS, ASS»IBLY HALLS, THEATRES, ETC. a. Seating and toilet facilities for the handicapped shall be accessible from the main lobby or primary entrance. 2-6ll{b) b. This structure requires _______ _ wheelchair seating spaces. In theaters and auditoi:iums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices. 2-6ll(b) c. Each wheelchair space shall be 6011 x 3011 and level. 2-6ll(b) d. When the seating capacity exceeds 300, the wheelchair spaces shall be in more than one location. 2-6ll(b) e. This structure requires ______ _ seats for semi-ambulant persons. Clear leg space shall be at least 2411• 2-6ll(b) f. Stages, enclosed and unenclosed platforms, orchestra pits, ticket booths, and refreshment sales facilities shall be made accessible. 2-6ll(b) STADIUMS, GRANDSTANDS, BLEACHERS, PAVILIONS, GYMNASIUMS a. This structure requires -----,----wheelchair seating spaces. In theaters and auditoriums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices. 2-611(c) b. When the seating capacity exceeds 300, the wheelchair spaces shall be in more than one location. 2-61l(c) c. Ticket booths must be accessible from both sides. 2-6ll(c) d. Participation areas such as ball courts, exercise rooms, tracks, and clubrooms must be accessible. 2-611(c) e. Spectator and participant sanitary and locker facilities must conform to the requirements of Chapter 2-5. 2-6ll(c) 1j-DINING, BANQUE! AND BAR FACILITIES a. Access shall be provided at primary entrances. 2-6ll(d) b. Wheelchair access shall be provided to all areas where each type of.functional activity o·ccurs. 2-6ll(d) c. This facility requires ---,.--,-=-::-.,..,....---wheelchair seating spaces •. 2-611(d) d. At least one wheelchair seating space shall be provided for each dining, 1;,anquet and bar area. 2-6ll(d) e. Access to wheelchair seating spaces shall: be provided by 3611 minimum clear width main aisles. 2-6ll(d) f. -cafeteria line aisles shall be a minimum of 3611 clear width. 2-6ll(d) g. Access to food preparation areas shall comply with provisions for entrance doors and doorways contained.in Section 2-3304. 2-6ll(d) h. Restrooms and powder rooms shall conform to,the requirements in Section 2-511. 2-611(d) RELIGIOUS FACILITIES a. Sanctuary areas shall be accessible. 2- 6ll(e) b. Provide --.-----wheelchair seating spaces in the sanctuary. Use Section 2- 6ll(b). 2-6ll(e) c. Provide wheelchair access to platforms, choir rooms, choir performing areas and other areas. 2-611(e) ---., . -·-----· ----.. raised lofts, similar d. Assembly areas along with enclosed and unenclosed platforms and stages shall be made accessible. 2~611(e) e. Sanitary facilities shall conform.to ·the requirements of Chapter 2-5. 2-6ll(e) · 2p. ASSISTIVE-LISTENING-DEVICES a. Assembly areas with permanently installed public address systems (other than exclusively for paging or background· music), . shall· provide assistive-listening systems for ~eople with hearing impairments. 2-6ll(f) b. Since the capacity of the assembly area exceeds 99 1 this facility requires __ personal receivers to be available on request •. 2-6ll(f) c •. If the system provided· is limited to specific areas or seats, then such areas or seats shall be within a SO-foot viewing distance of the performing area. f d. A sign shall be posted in a prominent place indicating the availability of assistive-listening devices. The sign shall. include the international symbol of deafness and wording that states 11Assistive-listening System Available". Group B occupancies used for assembly pµ.rposes but having an occupant load of less than 50 shall conform to all the requirements for Group A occupancies covered in Section 2-611. 2-7l~(d) SALES FACILITIES a. General sales, display and office areas together with related toilet rooms must be accessible. 2-712(b) b. Sales employee work stations shall be located on accessible levels. Employee work areas shall be accessible to employees in wheelchairs, and the customer side of sales or checkout stations shall be accessible~ 2-712(b) c. This facility requires -----,--check stands accessible to the physically handicapped, based upon 1 for 8 checkstands or less, 2 for 9 or more. 2- 712(b) d. Where quick check stands are provided, at least one shall be accessible. 2-712(b) e. Check stands shall be made accessible by providing a 3611 aisle on the customer side of the stand. 2-712(b) f. Accessible check stands shall be identified by the International Symbol of Accessibility and shall state, "This check stand to be open at all times for handicapped/physically disabled customers". 2-712(b) FITTING OR DRESSING ROOMS a. Where fitting/dressing rooms are provided for male or female customers, one for each type shall be usable by the physically handicapped. 2-712(b) b. Minimum dimension of room shall be 6011 x 6011 • 2-712(b) c. Bottom of the mirror shall be located within 2011 of the floor. 2-712(b) d. Height of clothing hooks shall not be greater than 4811 from the floor. 2-712(b) GROOP H OCCOPAHCY ~ ·1· a. Accessible sanitation facilities in all Group H Occupancies shall be provided as specified in Chapter 2-5. 2-913(a) b. Accessible floors and levels · shall comply with the requirements specified in Chapter 2-5. 2-913(a) c. F.mployee work areas shall be accessible by means of a 36-inch minimum aisle width, and a 32-inch minimum clear opening door width. 2-9l~(a) ADDITIONS, ALTERA'.IIORS AHO REPAIRS 1'0 EXIS'IIHG BUILDINGS. (2-llOA{b)ll) Toe area of · specific addition, alteration and/or · repair, shall comply with the provisions of Title 24. Additionally: a. The primary entrance to the building and path of travel to the specific area shall be accessible to the handicapped persons. Compliance must be shown, beginning from the existing parking area and leading to the area of alteration. b. E.xisting restrooms, water fowitains, and public telephones which serve said specific -area must be shown to be accessible to and fwictional for handicapped persons. c. Information regarding handicapped accessibility shall be posted in lobby ·per Sec. 2-522. 12/29/89 Dates 7/ 10/q,; I Jurisdiction G-rbhc:u;{ . Prepared by,. L+.CJ1.ll',r VALUATION AND-PLAN CHECK FEE o Bldg. Dept • 0 Esgil PLAN CHECK No. ___ cr .... 1-_j ..... ~=--- BUILDING ADDRESS /O'S?: Lcr.c,4410t.-/Jr. , Bl.la.· C.. · . · V J J . APPLICANT/CONTACT · D. Jq.u:=>b~£-r\. PHONE NO. ;;z7;;,4--'-/3/6 BUILDING OCCUPANCY T.-1 / R-/ DESIGNER PHONE_---'---- TYPE OF CONSTRUCTION . Y:,1 h~. /:rr-N? CONTRACTOR PHONE ----- BUILDING PORTION BUILDING AREA 'VALUATION VALUE MULTIPLIER r~.,.,_,,,,,;-4--6(_ +:/,::,o,c.. ..C...,...,~-~r-... +-, II '4-= .;?Oft:,SO (7/-tp3) · /toS ~00 \\,.-_.., ~ -,~ .~ ff .... fl • ~ • I .. ·- Air Conditionin£ Commercial . @ .. Residential (a .' Res. or Comm. Fire_· S"Orinklers @ Total Value : .. /&,S. ,5;;.00 I Building Permit fee. $ _________________ _,$~~8,....;7,_;0;..__, • ..a:::5;..::D:;___ Plan Che ck F ee.___;S:!:__ _ ___: _________ .:....-_____ ___:.S_....;5;;;..,.4?::.-5....:...:...• $..::._3.1--- COM MEN TS._•-------~-------------------- SHEET ) OF J ' <>, ,12/87 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB f/-?f'b ADDRESS _ _,/....._{).,..ifl9 __ ....__C_A_J_v_.,v._'-4_~_ ......... ~----------~ J RESIDENTIAL RESIDENTIAL ADDITION MINOR ( < $10,000.00) PLANNER j/4J ~ TENANT IMPROVEMENT PLAZA CAMINO REAL VILLAGE FAIRE COMPLETE OFFICE BUil.DiNG DATE __ 7_-_J'_-_?-'-/-. _ ENGINEER ___,~....._.i ....... L-.\)=-ie_--~---------DATE ) '3 ·9 I C:\ WPS 1 \FILES\BLDG.FRM Rev 11 /15/90 I / . -I'·.' >. ;,._.,,_':·,-~·,A,._ --:""7' :------·'' I 2560.ORION WAY ::,. - CARLSBAD;)CA: '92008 TELEPHONE . (619) 931-2121 ' / f I 1 <ltitp of (:ijrl~&ab FIRE DEPARTMENT· PLAN CHECK REPORT --+-· -,. ___ .. -- 1-1·\; ! E'AGE 1 OE APPROVED \--:-, ){ DISAPPROVED -\\ / / PLf/ CHE<z<f -/--; 80. ' PROJ EcTL~ \J , LL AS. Di f AR. ls, tsf\ 0 ADDRESS I D Cf;). L A&..i NA D l- ARCH1i:Ec,-S;1 LL !Vl,AI-J_L W YM/\0 ADDRESS .SA 14.....1 i>1 t::. C:-0 PHONE ____ _ OWNER ..:I::i\JC011,,16 P;iopt:,e:rf t;RoGtP ADDRESS SAI\J J);E,b O PHONE ----- OCCUPANCY Ii/ Rf CONST. '"$1. I t-1 R TOTAL SQ. FT. -----STORIES 7tltf I=-~ 'qlsPRINKLERED 'ruENANTIMP .. -fftq,££ I _t1Jl\..lUt.7E'S10,u oF IST-2;1/J FLocHL TD I I __ i, _._2. "-( !: _5, APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING' THE .FOLLOWING CORRECTIONS: PLANS, SPECIFICATIONS, ·AND PERMITS Provide one copy of: floor pian(s); .site plan; sheets ----------~-,-:------- Provide two Site, plans showing the location of all existing fire hydrants within 200 feet of the project. Provide specificaUons for the following: ------,---~--~~~.,----------- .Permits_ac.e required for the installation of. all fire protecUon systems (§..@nhleri)tand pipes, dry chemical, halon, CO2,~ hydra:nts). Plan must be approved by !he ·fire department prior to installation. The business owner shall complete a building information letter and return it to:the fire department. ' : ' ~ FIRE PROTECTION SY$TEMS AND EQUIPMENT -~ ·s. Ttie-following fire. ·protection systems are reqyir;ed: -:-J - '~utomatic fire sprinklers-(Oesign Criteria: ;c_,..,.._~ ~=--...,_n...,B=i<--=-_ _,_b-=i_,_f-'?'---'-A-'---'-1...,,3=<-___________ ) D Dry Chemical, Halon, CO2 (Location: _ _ . ) D Stand Pipes (Type: . . __ ~ . . . . _ _ . .. ) )&FireAlarm(Type/Location: f-)$/4 2~ 1-'L9 · 5TAT-£ F1t2c:. ·t,Vff'Jfl.Sf-/AL f-lPfJILiJvl:P 1 ) ~ 7. -Fi.re Extinguisher Requirements: 1 _ --~ _,. . . . .-~One 2A rated ABC extinguisher· for each taOD D sq. f~. or portion thereof with a travel distance to the nearest -,.. extinguisher not to exceed 75 feet of'travel. · ·------· ---- D A_n extinguisher with a minimum rating ·of ___ to be 1.ocated: D Other: ___________ --'---c'---:---------------'--,~--'---~-----,- --8. Additional fire hydrant(s) shall be provided--~---,---------'---,...,..------,---- ·EXITS ·_._9, ·Exit. doors shall be openable from the inside without the use of a 'key or any special knowledge or effort. __ · 10. .i._11, I ,. A sign s~ating, " This door to remain ·unlocked during. business hours'; shall -be placed above the main exit and doors · · EXIT signs (6" x ¾" letters) shall be placed over all required e~ilts arid directional signs located as necessary to -clearly indicate the location of e~it doors. · GEN~RAL __ 12. Storage, dispensing or use of any flammable or combostible 'liquids, flammable liquids, flammable gases and · hazardous chemicals shall ·comply with Uniforn:, Fire Code. ___ 13. Building(s) not approved for high· pileq combustible stock. Storage in closely p·acked pries shall npt exceed 15 feet in height, 12 feet on pallets or iii racks and 6 feet fortires,pl'astics and some flammableliquids. If high stock pil- ing fs to. be done, comply-with Uniform Fi~~ Code, Article 81. · . · ' . . '--l-14. Additional Requirements. . . _ _ /) PLfli\.L..S. A6\Ji) St'& 1 fie At7 ovs.. tv!L .fJrJ L/ Kt7.11 S:.1 oru s. TD fllfl£ vvt __ 15: -'S yi'TE'Wl -S HAl.L · Be SW3 n,,uTTEJ) . r - 2) d.o1crt-1iJ.otlS. ,1_!:J' I~ I Dl C.vt.Mnc 7 SJ/rrU. Oo.U1;0L7 t.,u177-I · U·'i3L 33DS . . :::S-1 IYl R 0-IIA fl-1\) JOlo7I l~oset..L€ $.T-=Frzc)u Sr--1,u iJi €60 CA '~J,. I Gl.l Date g/Z{n/9 j • ~ r l __ Attach to Plans '',. / SILLMAN/ WYMAN & ASSOCIATES ARCHITECTS Ir ENGINEERS 10671. ROSELLE ST., SUITE 200 SAN DIEGO, CALIFORNIA 92121 (619) 4!53-4320 JQB_V_t~u..A.=....""--,..__'CE:.=..<--..CG: ....... ....,:_IZ.:..,L:5=.i:l;=,=A'-"-=O=---------- SHEET NO: ___________ ..,_ OF !!!J CALCULATED av _________ _ DATE ________ _ CHECKED BY-----------DATE-------- SCALE : ~.I.~~: .... O"f', ........ l .... 'L ....... ,.,+, ......... _ ......... . ............ .... · ........... :,-..... : ........ · ............ , ........ : ..... .. : : + : : ' '. .............. :, ........ "··=··· ..... .; .. .... . . ..... ~ ........ , .......... : ........ i,. ...... j .......... ..L. ........ '. ......... ~TI.~\<;,1,:t?f,,~ ........ : ............ ! .......... : .......... ,i.. ..... ; .............. , .. . 1 ' . ~ . ............. ; .. I?.9-Pf.:'. ....... Y,::::'.i .. --.... '.,;; ...... " ... .'.Z.4.. .. .............. :. .. ..... , ....... : .. 1.. J.... .... . .......... : ........ ·:" .......... , ............... , .. . ........ ) ..... RP.P,;, ......... ; ......... , ............. : ........ : ..... ~;s ......... : ...... =~ ... ~ ........ ; ...... ~~ ..... : ........... .. .... ....... 7 ... F,,;P.Pf.\ ........ ; ....... : .. .. .. · ......... ; . . .3.~ . . . .. .. ..~ ..... ?. .; ....... :.l5L ... :..... .. . . . . . ......... L ...... ; ........ : .......... : .................................. '\::\ .............. · .... i .......... U.9'? ....... '. .. . .. .................. . ........ ' .......... , .. '!..T?!P..~.;: .. ,. ~ ... Q, 1~ ... \1.9.~) - ·.········· ..... , ...... . . ; . ' h w ;.._ ... . ... . .. ... . . .. . \---~ 0.;,,-·... . .. ... >,.._ .. \,,,: I ' ... !l't,\..W•? ....................... 1.;:;~? -.. r . ... z..1. rz.a . ... \ ........ '2,-'; y~ .......... : .. ······· .......... : .. ~. ' ........ ~ ~--· '. \.6 ... .. : .................... :.'.? ...... " . . ... . .. ...... '1 .. ...... ?..~ ........ -.... 4..4_·;:: .... . : : .. .0\1'.\c;:._. ~ :'::l. 14,.1 ...... i~A . __,. ... 2 \8::>i ... ...... a.~ .. .............. .. 1.'?.,~i ....... \J,'5i i'Z- I:::; ::= 1, - .' '3 '7{$ . -13i \_,¢, <Y/_ .I.~ . . , . .J.D\. ... 1, <'.::<'..; \,.QC; s.A. 1 ,4 + .8.--\ .:=. \ S.::~, S.'/ ..... -r. iS./ ... = ... .\'1·~ . l1. ................. : ..................................... . ~· .. ! PRODUCT204-1 {Niflls) Inc. G1oto11, Masl 01471 SILLMAN/ WYMAN & ASSOCIATES ARCHITECTS • ENGINEERS 10671 ROSELLE ST., SUITE 200 SAN DIEGO, CALIFORNIA 92121 (619) 4!53·4320 JOB------------------------ SHEET NQ: ___________ ,Z,_ OF=d..__ _______ _ CAI.CULATED BY _________ _ CHECKED BY----------- SCALE DATE ________ _ DATE-------- . . ; . . ; : ; ! ! .... r ....... , ••••• : ....... : .............. • .......... . :::::.:::·.·.r·.:::.: .. : .. :.; ... ::.:::.:::1,: . .-.... ~:::::: .. :; .~;4-~ ... \.b.;).: .. ::::;~~;:::::.;.-: ... ·.: ... x.-~i~·1· ......... r ........... '. ...... ··i ....... ; ......... ; .......... ; ........ ; ....... i .. .. ----; L __ i __ i, __ ; __ j _____ . : .1. [ .. : . ;_j ___ , __ ; __ : __ i-_ ·----i-,-~-- ............ : ........... F~ .... 1 .. 1..4 ·i ...... ~.~l"' ......... ; .. ~ /. ... U ~,:... .... 9..17-..... -r,c~ ..... 1 ........ (\-p:~ ..... ; ........ f ......... : .................. , ....... --' ......... .. ............. : ................... ,: .. . ... ..... ····;· . ··: .. . __ LJ . .J L~~is.i~~-( -~{,,J • s~~;_:::; ... ~~.'. . . ; . ; (3/,4"" .:C,-r: '"\<:'.-;; .. ; . ,.,.,.,..,., : ., ......... ~ , ' "' • • i, " ' .,j •• '"' '" .,. • ••••••••-,•• ~ ... .,.,; ' •I' ,., •• ' t ~ • " """' ' • ; ,., . .,,,., .. :, ,. ,. ' •• ~ ...... "' .. ;,., ....... .,. ,., " • • ! .. ,. • ,.. • ' ' • ,. ... , ... " '!' •• • " ~ ,. ... ' • • • ...... , .. • ' ... • • ' • •! ., ...... ' ....... , " ., •• •• ""' • ' • •• ........... ~ .......... : ........... i ..... ~.cvr=-: ............ : ........ : ........ : .-z.1.'3 ....... : ...... : ............ : ......... :, ... ; .......... : . . ..... :.~~.? ....... : ....... , .. ( -z1?. )(1.,q1J. =: .... J.f~ .. '. ...... p~~ . ............ ; ........................ , ....... ~ .. 11 '." ......... : ............ : ......... ; .. 3?;5'.3 ..................... : ......... ;s. .... J ...... ; .............. AS..9. .... ; .......... ; .... ·.iB.'3.. Q.p~) .. : .. ..4¢~: -- ........... L ......... '. ........ ..!.... ...~. ~~.. .. .. ; ................ :4.'I~ ..... : ....... ..L ...... : ........... :J:c; .. [ .......... ;.. .... ... .. ... ,.~.7.9.. ..... .:... . :.. .. A-7~ (1 . 04.cJ..':".' , ...... "80 t ....... ~ ....... .. ... .............. ........................ : ...................... : ............................................ : .................... :-....... :,., .... · .......... '. .. . ' .. ...... · ... ··r ......... , .... ' ............ : .............. :3'2;9 ....... .; ........ : ....... ;.J. .... '. .. .......... '. ............ ; ......... L.. ............................ , ................. '5 rfs .. : ...... .. ......... : ........ i ....... : ........ '. .............. : ................ '}IQ .. · .... ·:· ........... : ........... JQ.' .... : .... '='./ ... J.1 .. 1 .. . ' I • .. ....... .. ........... ,. ...... ! ......... ~ •......... ' ............... . . .......... . \ c.;. -.:=;,. . . ic..~.3 ... : .:..J-. ... : .... : .. '.E.' .... : ... .:.1 .. .... :.i. .. '. .......... .. .......... · ........ -. ····:·· ........ · .. ' 3 .3 L.. .. . .... .. ... ..... . :r:. ;.. .... . .. ' ................ . ,., .--i 1/ ' ........ : ..... G.: ,,. -:i •:.. . w/ : .I ,5·. ........... .. · ..................... "' . ~-· .... , . .. . . . r 'J j ......... : ...... ~. t?. .. 8 .1 ...... :1.1,.).j.. ... Ji.~ ..... l IB ...... .' ............ I... ...: . -; . . Z\o : : ! . ......... ,1··· ..................................................... :······" ............ '"'""" ........... , ................... ···;·--· ........ :·-. ... ........................... ................... ............................ ........ ~&Q ...... ·........ . . .I ... . .. .. ' ... ., ............................................... -· ..... . ... ...... .... . . . . .. ..... , .................... ·-:· .. PRODUCT 204·1 /NE:Bsi Inc Groton. Ma1, 01471 :.'/'I b '2 So ·.:2.:09 t•?a ..... , •• '.,r:'., ••••• : $!'.;__) ..... :::iz..;:, ( 1 •. o~) . .~ri·s[, .. 9"" ). .. -=- 'l\ :..) ( \, :.) ~-.::. .. ..._ ..... .,,, . \ 5-:) \,\,Ll\ ... 1'7G:, /, , 1 '-!, 1,-: ) = '2\ -... ·,.) ~ '--' \,,.\,,(.)~~ ... -:::: 3"'10(1,,c0) = G.).0 ...... V --- l7:3 :.--' ;, '3 "S .,.. 4\i ._,..,. SILLMAN/ WYMAN le ASSOCIATES ARCHITECTS • INGINHAS 10671 ROSELLE ST., SUITE 200 SAN DIEGO, CALIFORNIA 92121 (619) 453-4320 JOB------------------------- SHEET NO'.-----"------~-OF$ CAl.CUl.ATED BY _________ _ DATE ________ _ CHECKED BY-----------DATE--------- SCAl.E __ : -~-~\o"i-';'"LL"J _: ____ L __ ! j _ _J [ __ : c::r~r-r+: ::· ___________ ____ . ____ _ --_--r--r-f ;;+· ttTJ~is-:----r·-:---·1 __ -:-·-.---__ :·-----_ r----: ---,--;·· -:: _: :-, ••. -• ::-••~:-:_: __ ·: --::._ --- 1 ; : , ; i ' . 1 ! : , ,__ ___ ; __ ; -: : l : ~ : : ! . ; ............ ~ .................... : ....... j ......... r ........... : ...................... ······ ................ : ................................ : ..... . __ !__j_ _! ___ J ___ l__i __ i =~~ : __ · -~ J _/-J;L_: _ : ___ -J::t -__ L-_---• -:·_._ · ~~:: · ,'.': ~ ~~=-~-4;~ .......... ; .......... 1 ............. = •........... ( .......... :··: .. ····+· .. ········: .... 510 ............... ; .......... = ......... : .. ,,.;······ .. r ........ · ... ~.'.§.16 ........ '. ........ : .......... : .... 5-.l.o .l!l,Q~.:. ~ ... ?..4; . .L. ........ ~ ...... . ..................... ; ........... · ........... r ............. i ............ :,. ........... _. ....... • ........ • ••• ' ' ! : . < • ............ .,,, ............... " 'f"" ... ,,c,•, .. ~ ...... ~ ....... "•:··"""' • .. • ... • • ....... .. · : ''ii LliwE 10 : ................................ c..;:;, ....... !" ................................................... . ................................. ,s.4 :. ' ' ............... ., .... , .............................. . ................. ~~9.. .... ... , .............. ~;36,. ........... :. . ............... i"" ..... ·:· ....... ~: ....... >' ................................. , ............ · ...................... :--.. Ne . :. ; : ; ' . .. : .......... ;........ .~ ....... -· ~ ....... ; ....... ··--·; -.... . ! . ........... : ................. : .......... : ........ i ...... . 1 : . . ·T = ............... , ............. : ........ : ... .,.\ ..... . .:J ... : ....... : .......... . . ............... =... " .. :.:r.. :. " ... ; .... . . .... ! ........... :··· .. / ............. : .............. : ..................................................................... : ....... · . .. .... : ....... ; ..... ·: ........... : ......... ; ......................................................... . ·.:BO . , .. :• .......... :· .............. . A.'3,0 . ..... , ... :··--'"'" .... · .. .4.;,q.. : ...... . . ... \ "1.4. ...... C !. •. :?.\.)... .. . . ...... . 4~G:> ---.. ... . . fHGj(+. ............. : .... <Z-... y.'\.-2-l;i.t!;,'.~ ............. w~-n:.r.:-~ ...... ; .. . •· ... ~. L.1.N.s ... ::\ . .. ............ ·~ .. ., ................................. . " ............... ·t·· .. ........ : ............. :z.-z \ .. . ..12;:sG. 3.3 7. ............... ... ........................... , .......... , .............. '34 . ..P ?ROOUCT204-1 1~1nr..Gr01on :Jass 014/1 ......... , ······· ........ , ... J. ............ , ..... . ....... '.2~4) .................... . .. ....... ; .... ~ ........ ;.~ .. ; ........... : ..... .. .... .4?..P .... i .. ·······, ......... . : \<.. ' : ........ ............. .. '"' ......... ) .......... !'"''" ' .... :5..1( P. ..... ' ····· ........... . .. .. . ............ . .:l. .. · ........... " .. ;.~~¢ ... ' .. . ... : ...... ;J.. : .......... : ....... .. ..A.~s:i ... : ..... ; ' '""!"' . ; . A~>~ . ....... : ........ : ...... ·~ .......... i ............... ""t .. ?.:,--:: ....... . ' . . ....... . . . ..... '.?.Zl.{i .. 01). ~ .... 'Z'.2'.3 .... .. 3?".f(\.o~"i_: 4PL ... 4"\o (1.0~. :=· .. <:>i,p - C SILLMAN/ WYMAN 8c ASSOCIATES JOB ARCHITECTS • ENGINEERS SHEET NO'. OFS .. 10671 ROSELLE ST .. SUITE 200 SAN DIEGO, CALIFORNIA 92121 CALCULATED BY DATE (619) 453-4320 CHl:CKED BY DATE SCALE ~:r: ::;:-~~:-r~~~--rF:trtr_:_ -:::_:• :r :--·t ::1:_-_-. • -________ -.--_-_:: ____ _ :~:I~~k~;i)Cb. ~JZ~ t: ;~;:c~-r::J ~ r-->::;·-r \~-; :T : :T _-;~~i, .~;~ ~ : 14~ • -~ ___ , _ i 14'\' -1G'3 ; i I' . ' . 280 ; ... tc..:?· (\O(o) -·'Zif'\ . -:.::=1 _·cir4L. c:~-:,ks_•=~ :t{ r :: '.=:-4;~·-::s:·iJ _325~,.~c.:_-~•-o'\6. -~ ------- ··+···· .... : ..... '! ......... ~ ........................ ,: ........ ,i., ,,; ........ • .. ••••••••••:uo • . ' ........... .. . ... . ·:·........ .... ..... ............ . . .. :'"" ·t·· ............. _, ....... · ............................. : ................................ . ;, .... : .................. : ... ., .. . ••• ••••• •' • •• .. ... ~ ........ • •• : ... , .... 1 ........ • ... ••• •••• ........... ".J ..... • .. • ......... • .. . ··t •••• '" •••. _.. ••• ""('" ••• , ••• ,; '"' ' •• ' ......... • .: •• "' •• . ·":····· ............... ·;-·· ..... . •.••.... : ................. :. _,, .. i •..... : ........... ;, ,.. •. •. •• • ........ ; • ..•• . ••• ., ..... · ..... • .. • .. .. ..... . .. ,...... . ..... c;1*e~1<; .. · .·.·~:·:··:.· .. :~····.i .. · ... ::::.~:aj~r.L.·:.:·:~:~~~.~ ... ::·· ·~~.\·.~·~.·: .... ~·.;.·: ... 1~·:: ... µAi£ ..... : .. L-o~q~ ...... : ..... : ... . . . • ",. •• ,.,. ••••• •" • • • .... ,. • •• ••••• .. •••• .... ••••m••••:u•u••••,>•o • ~"" ••••••••••••, • • ., •••• .,,. " ,_, • • ""' •.,_.,..,,.,,:• • •" • •., "• •••• • • •• .w . . ... . .. . . . ".. ... :·--!.~ . =-: ........ 4½!~ "'l~B ·)1~ 2 ~0 .. ·· .. ·~;~··0~) .. f.{4?;3 .:.i?iJ;,)l(-z .. ~ ~ \4co~ ... ... 1r71·1 l~i.'2.':;\\ ... ~ 2.S -:::: .ft10 A)('-\ ·r.o~, l.::\:'\.'? .. 3.4.?.0 ... ~.It~. '2.. I -s:° ·r , ........... ; .. : ............ .-. ; ... ·.· ····.···']· .. . . ............ . -~·3·~··"" 1.9 t. (4~e.-:'2.1?i)Q,0 .. t.~4.t.:-4.3·~~{5J(~-~) .=. "US:-~:-S ~ 2d, B6 1-1 .. ~. . ..... H...i.> ..... '21.34 17 . 7 '2.=5 :=-"\ '3;:i ·-.. -.. 1-\0 'I ......................... . . SILLMAN/ WYMAN & ASSOCIATES ARCHITECTS le ENGINEERS ........... : .. ······· : ............... : .... . ............ "' j ........... : .... . ....... .. ....... ....... ... :, ---.. ,: .... ., 10671 ROSELLE ST .• SUITE 200 SAN DIEGO. CALIFORNIA 92121 (619) 453-4320 ! . ' . \. : .. ) ' ' ' : , e'i"-,\~-: wA:u.. \..ct-):;:-;:~... ~ ; '2"3 .................................. ': .... ... . ................ \ .. ,.. . ... ' . . ... . ' .. ', ....... " ........ "' .. . ..... ......... ··.···· .. ····-·· .............. , .. ,. . ··---···· :·· .... ; .... ··;···»· ...... . . 7::-' .• \.· .. , I;;. /1.'1 .•. ''. . . L.0,\_<-.::.,.. . i'!::\?"'r"' .. r ... -~;,J • :· ...................... ,. ..... ! ...... : SHEET NO'.-----------L- CALCULATED BY _________ _ CHECKED BY----------- SCALE = .!5"0-Z.. -'Ill/ /1..:F / ... I • ' ' . . ... .. .. . . ...... .. . -... ~--~ I .... :3 lb = ......................... -:·· .. ····:·---·· --So,,.:r.:,o : ....,..;ti'! ,,/1,(~'\,~ t:!) . · "P ·""' "'? ·, I <.;-,. · -• ' 1<1 -:i •• -. . ,, ,.., ................. \.; .... <., ... -;r;,.\ ,.-., --; ... ·•J .. --·"" ·-.~ •. ..... } ..... , .. :···· .... ·:·· .... . . ... : .................. : ......... . ' ........... _ ............... , .. ,. ... . e 1 4 .' . 'fAl-,;t:"\.. .... ·RTM. .G09 .. ( 1<-\_7~) DATE ________ _ DATE--------- \ l4Bp .:7.1'-\ =-ol.p ······ ............................ _,, .. .. ' PROOOCT204-I /Nifl!is/ Inc, Groton. Mass. 01471 __ ____J SILLMAN/ WYMAN 8c ASSOCIATES ARCHITECTS.& ENGINEERS JOB----------------------- 10671 ROSELLE ST., SUITE 200 SHEET NQ'. __________ ~c;~ OF_,,,8:;___ ______ _ SAN DIEGO, CALIFORNIA 92121 CALCULATED BY ________ _ DATE _______ _ (619) 453-4320 CHECKED BY----------DATE-------- SCALE ' . ·.~f-=·=·-~:-~--~·~~.~~-~ .. . _._._._._._._._. ....... -. .-.-~::.·.'.:::::.ii_.·.: . .-·J ..... ;_ ... l~-: . .~ .. --.. ;_. -·!--·: .... :i ...... E.~4l4 ·:-· ...... ···f ................ , . . 1 r. 1 .:; .. -· .) .. _ .. [ ..... ; .. t~~ ... ;-L.f _ .. Pf. .. _;._ ~rzr ' . _________ ,....j : . . . . . , ... _ .... ; .... -.. ; .. -·-.... ·:i ..... ·-nx-·· ; 7.7. : ............... ·.:.·.·2 ... '\.·.·: .............. ,·-.·.·.·1-, .. '\.., ... : .. ·.· .... ·.·.· .. ·· ... ·.-\.:~.·.· .· .. ·~~?t.·:·.·C'fl.,N<:,. -=~ ~: .:::it:::" • ; -''; . . L~?-Gie>) 'o-~-. ::2 .... . i ! . ' ; ' ..., \ \ .... , ... : .. •••••••• ,'_,, ••••:m,••n : ·-···-··--.. -••, .. ,, , ... H .. ..,.~ H • -f ···-+ ._.: ........ : ..... -···1-.. --... , ....... ; .. _ ...... .. . .............. ...... . -·-·· .... ; ._.,. ... _ ............................ ,. -~- ..... __ .. i._ : ......... -~-.. _ .... ! ....... _.; .1 .. 0 .... \3.P~t"\_. ---------- ............ , .... : ............ ;······ ................. , ....................... . .......... : .. -· .... -....... ; ........ . ~r.;c~r;;. .. .. WGt\-. . 9f.' .... qj-p Nkv..._ .:f .. ~-r: I = . .\.l."5 L.f ___ >l.8.1. ~-.'9_:Zo rf.. .............. r .... ! . ······1-·-· .'2 \ X .1.. +: 'l._''.L .:< '! .. \-l '< ':"\!. .. llP <:-f .................................. -....... . ........... ... .•. :. ····f .......... "" \~94 ~ .... ' ' . ·........... ...; ...... . . ..................... :, ................ ,: ...................... . . . .................... : ......... ; ....................... , .... . ••••••••••• .. ••• •• • l_ ......... ., ........................ . . I ............. :···· .. _ ... •'"·-:--··· ., .i<!::?V \ 'SE'D: .. CA_i...C:. -:-.., .... A."D c.:s:;;, ..................... : .................... ; ......... .. ......... , ......... : ............. :. .......... ······· ............. . ........ : .......... : ...................................... · ··- ........... : ............ : .................. :, ...................... . . . ............................ ,: ........ ., ..................... .. PRODUCT 204-1 /Nfias/ Inc.. Groton. Mass 01471. SILLMAN/ WYMAN & ASSOCIATES ARCHITECTS & ENGINEERS JOB------------------------ 10671 ROSELLE ST., SUITE 200 SHEET NO'. __________ ...__ OF a SAN DIEGO, CALIFORNIA 92121 CALCULATED BY _________ _ (619) 453-4320 CHECKED BY----------- SCALE 1·--· · ... • •••• •· ·····r·· • . ..... .. • ...... : ........... = .......... ·r ..... .; ...... ~T ... . ..... ; ..... ": ............... " ..... --~--...... :. . ... ;;.._ .............. ,. . ........ : ........ : ......... ..i.... ..: ...... .) ... F.; .. -J .• .. ' ·····;•• .. ,.,; ........... : ....... : ........ ._.;, ........ ., ...... . ... ;.M ~x ..... i.. .~P~ ...... ..J .JA:'.. ... .... . . . .. .. .. ....... .. ........ . . ... : ..... 9. _\f.\.c..' .... L..;.:i:rd.. . .. .L. . ~t.?. 1t. O, ~ ... + .. ~ 91. ~.1.. .' ... : c;.i:s -,:;, .... . ........... ; ........... ; ........ ; .... "'' ·!·· ....... ; ... . . ..... ~ ·-............ . : + 3 . .................. :____,,_ . . . . ...... .. j· ....... ~-......... ;. . . . .... . . . .. .. "" : ~ 1'1-........................... c;-.p .. ·" ................. : ......... : .......... , ..... ..... .... . . . .. . .. : .................... "S. ;==; :9 \ :c,~ij_(l_,~),/i .. ~~-?. ... ,.:.~. :.Jt?.:A . .... ... ............ : ......... : ............ . . : ; : ......... : ............. , ... : ....... ;: ................ . .. ~ -=: .. ~ \ 64) (\.!~ / '2. 6-s): .... ,:..... .1.0 ... 1 ' ........... > ........... :... • ·--~· ........... : •• • • • ... • ••••••••••• ' • ........ . : .......... '. .......... : ......... : ......................... i..?' \ . .:t.. ..... e. \c.'' Q\<,.. ........... -;:··-····; ....... : ... . ....... , .................. ; ........ L. .... r.--u.-;,\;'-:e~Y·-.-~-,, . Q_-\,JNi.f~-... . • l •••••••/•• ,m••:••••••• .. :,. ' •. ,.,,.; .......................... _ ... -· .= ........ . : ! ...... ............. .......... _. ''"\""""' ··- .•... ···-··· ····1: .. .... : ........... : ............ . • -•·-•• u• •" ., : -•••••••i•• ' ' . .. : .......... :.-.............. t .......... :·· om • ;, "' um•~•••,.,.. H "" 0 ,,.r ~ "' ,., • ........ ..! .......... · ................ , __ :_ ······· ........ , ........................ ": .... . •• • -:•• .. •• .. "'•:•"• •• ;• • ••• ,-r,. • ........... ; ....... : ....... :··· .... · ..... . ......... _. ......... \ ........ ' ......... ;., ..... : .. . . I .. . .... I 'Z. "=::f'tc\'i:::{ ...... :. . .. V .L :: ... 9..?.. " : \ ?:/:"?-:::. 5'.~ 0 :· ..... 4Y:. \.t.. < a·(.;,-..')(,;:.,·/1",::,. .... -= ,';, ,.Q.\.\.'-. /..:. \'~/ .. .:,-. .,.iQ ... A.'( "' ~.~.(,i/~.-.,'\)(,,c;.) 1~.5-. ~ .... 3-; 0_1.,. -~. G-i~.~: .. ~.9/2 + ... ~'Z. ·" .? )' \1.,x~ "S:::. .6.'Sc>:(Ca ~)(,:1$)/11,:s0. -'3<.,. .:A .. ~. 5 6;) (4'-0 .. G,'2)/~s = 4o .. z.. O)~ .. .' .. "••••--•••:""••• .. • • • ,. ..... :, ...... •••"•"••m••" .. n .. ,:, • • • ,.,-., • •" .......... +··· ····;·" .......................... ·-................ . PROOUCT204-I /NFfi:fs/lnc.. Groton. Mass. 01471. DATE ________ _ DATE _______ _ ... ... . . .. .. .. ... . .. . . . .. ·? SILLMAN/ WYMAN & ASSOCIATES ARCHITECTS .t, ENGINEERS JOB----------------------- 10671 ROSELLE ST., SUITE 200 SHEET NO'.---'--------_,_""--OF-'O=--------- SAN DIEGO: CALIFORNIA 92121 CALCULATED 9y ________ _ DATE _______ _ (619) 453-4320 CHECKED BY----------DATE-------- SCALE ..... · ...... :.,, ' .. · ......... ~ ............. ····: ..... . ~: _:: : ::~~ • ~; ;:;_,:~ -_;::)_('?TT;s;,;_F\i ~ I~ _ -CC -~~ 1c,~~~) · ' • ' I 'Z. -C.. s~ · ' • · · :·· .. ::.: .. t~·.··::.L.:·:·:·:·:·: .. :::::.r·:··::::·-r_-:·:: w.~ .·.·~::~:·::;-.. :. \ i:~i~·::.~ ... ·;·::;-;·~ .. :~~·~ .· :;::·; ;;-i;.. ,::;:·::.·.\·~~·::.:~ .:·~ :·····. = -~-'.~-+-+-~-:-_ : : l~; _;;;,;;;; _ + -'A~ ~~-+~j > lfJ 1 . ,4 .'?~?9. ... ·15:, ··········'·····················+·· .... ,............ N .... ···-;-.--· ···~·)· .. ···x .. :.. , i .. ,~ ... · ........ . .. ........ . .......... ........ . .. : .... : ......... .. .:=-.'30 30 ... .,J.~·~.· . ./ f3 .. 7: -,Cf/~: ...... ,. .. . ......... ...... . . ... . . ............... . ... :. S.: ... -c '.S<t~ .. ()zJ../'2,:1 ... ,~ ....... o?,~ : ..... i ..... : .... ~ ...... ~.~ .•. 1 ..... . ...... ... , ......... , ........... , ......... : ......... , .................... ..L.-;. .. ,zi_,~(~?.p)(~f:':5-4)/:2'\ "19.~ ... ('.~'..o/~). .. :=.. 1.30. ' . = : : • • , ............... · ........ t ........ :·· .. _ ..... , .... .. . . ......... _..... . :· ······ ·: ... ·-..... ... . . ' ' : : ~ I \ ,1-.................... , ....... i ............... ~ ..... 0 Y .... ~--.:: ...................................... , .......... . i ......... : ............. :. ..... . ....... . .... ... .. .. ; .......... ! ........... I ......... : .............. ··-•. . . ............... ••·······:· .. ·······: . ..... ... ........................ :"', ...... ! ....... . ..... .......................... 1···· ........ : .. ···· ...... .. ,. ... • .., •• ,,. • ••:••• • • "•yu"''"•" • " • •" '' ...................................................... ··- ' ...................... :--····--· :--" .... ,-..................... _ ........... ! ......................... . .., ......... , .. . ' PROOOCT20C.t /Nlf:es/lnc, G101on. Mass. 01411. · ..... --· , -: ,, ;· _-':",. ,Gjty~of-,_<;,;a;J~l)~d:,,:-:-.>_.-· 1 _-,-__ . .:,.· \,-::;· \·-; · .· ---201:SJ::alJ?:aliµaf Df.i-ve:· --: , _ . .. . ~-;"-; ·: .. , .. --.. ee.-. ,_ , .-• :-·.-• , • --. ,. : • •• • . ~~·.·:. : · .. :.--RiB::.-V1t1as,:de ·Gatlsbaa-'.Plan .. CheGk #9L-:986 ·,:,.-,:, · · · · ---, -.:· .·, .. " .. IL ~~~:~;;y,,-yj~,,{~~·,?-:\(f f j}'::f t!Ll3!~:i{, ,.\<: , . . . · . · .· •. . · . . . · · . __ ~:{t -{( 09ti'-ii£J~i½~~6\~-~g1~~ i!,hi:r!.6.Y~~tijtj§i~:~~,iT-ii~ly':~¥~.T5l89.:":t~: alJ~w 'n~n~aizjbulatory° p~rso~~: to '.occupy : _ \ ~-':· .; t~~-!se~_ei);_~_:,'fl~~o~c~Qf,_::Blfil~i:rg/C :ti,t :it~\aS'':4.eiG~d~~~~;~_::-'~~ A9-SC?, ~t is ·u:e~e~sa,ry to promd~ ~ -hou~ ~;~_"}-,·.:/~~sf0:~~~;~:t~1{f1~~-~;~f~i~t~-!\f ))}:f}~1·Yr~~>-?t~:<~r/·/J~:.i_:'>.'-:--·:_--_.-_-. ·: __ .· -_-_ ·:·. -: · -. ,?>-:./Aft~~~~h)h¥js~~rtrb1t~1IfJ~ffifq(iddf~.s·s.1g¢~~r[ati~1~s}w~~biv~::agFeed~~h _yoµr _offic~ to ·consider t_ne· _·: -;~"_; /--.-_'Er~ftpifl'.:~~~~p,<ffi.~br:-~s-._JP:ir\ 9:Q.~Y1PMW~;:)l:~~\t:1!.e--:fpits(flp'qr:w_m _rem.ahi_ :air ·R,-;1: .octit,p~u,1cy .. With-that. · ., ~ · _ (iif~m-¾n~l{{t~"~h~~~)i~ff~~,4pJ;qrppr,Q_~i!~ ~~{rt~~ifprst~r~JP,fl(}1_ftlie: r.-_1-6ttupa:ncy~ . :~ey "include, b)-lt-are_ ';,_~:·, ·._. '{~9:\l,~t~~:; YJ{f ~l~,~-. !~~?!,1~re~;:~igq!,-f ~9t :~~~~~~-~~f rJ~:_?IS, :f 9rty~ f qj:u;_ incli-~id~ ~oors, etc. -. . .- :~~ -~ · }>:~_:-~(~~ -~~-I:"·-:~:\·{,~~2~~.·~_:•"7/;:r::J;:;_=,:-·--\~~:-'.::~~·~:~t~-:t.:~t~z: -~~:\,~~~;:~-~~~~:; ~~;;=·~, ' .. ~~~~·1:~/ ,,_-~-.~ '~ . • · ·_ ~. • ~ _ ·:-:/:·,, : 1*.· .qJ}d!\~0:q_/:¥Y.'~~r~ :~$-~g: tJi~t,;-tli~:T:~g_'tj.jJ;em,~fJ;'t Jp_pt~i:~-l;t~~qicapp~d_ accessable -µnits, pe wa_ived and ·the ' !_i __ :°t;_ ·ierp;oa.~1ihg: ,Ji~-.b'~,$~)r_:,ot1·_t t~e, )98''.?c JJ,lq~·th~i{,W;~~)bteff~_cc ?( the ,-timy· _ _of the otigip.al construction'. .. <.: ~,----~ ':~py~~fi~~lly;-:thKt)'f0,1!~~tM~~ate':t~~)~iufi¢_tli~1f(i«?-f I<:1w)fveJ: exi,t __ signs _and VISl;lal warning devices. -.. :. -. ).·."~_;_::.~ __ 1't·"r·4··-:_·,-,.~;-":_~":,-•1' .. ~->-~ _ .. __ ._"'-,.:S:_"'--:!',J.._: -~,~--~-~.;J.·1··:-s··>·:::;\ 1:'_:-:;/.r~1£":.~::,:-.:_-:::~·;~ ·~"; .... > · ·. ~ ' . · · . - ·':::·.,~ ·,, -~-~, _Mf. ·tv,it ~d1~~t)fg~·oil;.c.9.~oia(i~A\h~d~~~~~ltii:l~i(.~it -~!-an :·~fre_ckand we w0uld like. the ·remaining ::: _-.:. -~Jtyli{sJ9.-pi.13es,olv,&dJri.:~1;1fmijtfo~f~4/Mti-.+0ny.l'y!afin1iicl>M~~-J:irrrf{ir-Fis o~ J0oh9ay, Augu~t19, .t991. · :,:t;'t~mi81{t ::·; '.\~/j:F':far(~:}}i{i~'.~i}~i'.i/,:.:::) ": , . , .· . . . ·· · · · · . ·· -· .-· SllJ~hWYMAN INC·· "· .... ·-.,_ ··,. -. --,-· .·: , --. . - ·':-'•.: :.cti_-;,:.: .·Toity;:Mafa,::pHh&jai'B:a{lt1ing:~Iiisp.ector-_;_:'~::/~' : :·,: ~-~ : • t_ • \--:~ -"\.: .. ,· .i .. ....;:: l~\~,.-~~.;·· : ...... :,;:. :-.,,.-. ,t,.. ., ~·, ''-...;;,,.,. • ••• • ;-.. ~·.,.,..-;''," .. ::,.';.· ,"--··:\ <--,:.·:~::,:~:}1.~;_Hat~1§;,:1¥~1s-ta~t,,:~l.Ee .. M~~~~~ll,~/='·-;,:_:~:·,, .. _ .. '.. :/:_:<"-_ · --. . / -· :·-:-·-.:~:\-{;:)YJ.~~¢\~fi¥~P.,:~~¾fr.N.\}t{~h:a:~F\.i . .-/:~.,, /-_:;?-'-?:~-\-_-· -~:.,-. -~ ':; . . .,_,., ::· .:. -~-. .-<--< Ron<:·~.o.:en1s;,:tt;:.:V.rllas .'l)y--Carls0~a;0'Lttl·/, ·-· ·: . ·, -, -----:_, ') :: <·:_t·(~_~/(f·t?\y}\,t\)j:.'.::',:-~,·:,_~·-;y··=~~:;/.>~:~?~({:.). ·;:_;.-,--'~; '.-?: ;~ ~-:·-:\~_::· _ _: . ·. . -' ' - ·-·::,-., .. -:--.'z.··<c--.-::,·.:.: ;._,,_-.::,: -. · ·:Sif'Ll/M:A:'·N-/":WYMAN··· J'NC ~:,'i· .. -~~ .. ·.~_-=z_::-~·--:---~,,.--~~:?.\~)~'::·>r,,:::··.t··~·-··~--~:_.·,,·, _,:,fr',~,~-:,t::~~~.:-::,/~.'::,.::.:·:~~~\~•:,~·,'·~: ~'':, '.K,'~ :-_•I '• __ ,·~,. _.•. ,,,_ .. _ A' -'"R•"·C:·,·'H",,-I•"-'-";f·"fr -e:,,·c_r·.,u "K"·"-•E ,_._ &'•" . B-N· G I N "E E R .I· N ·a __ .. ·:-_ ·<·:· .. :·/,;;::.:\>·:-::·:~·.<.:'\-},:/,J.-,;:-,;,7<-:{·_.·;( __ ,:··:·>t:;,,,) . .-:~-··:·;:.-/-:-:_--;:_::\;~··,\ ____ ·,;. '.. · .. -_· . ·-_, .. '.~ · :. ·..,__.; '· ·, .-, -"9609.rWaples:Stree½ ·Si.nte@O,;San'Diego;;Ca)jfornia'.92121 ~.0FFICE (619)·453-"4-320, FAX (619) 552-1563 : .... ·f ;':iJ.tt)\:::"··.·f{f \::F1t~]1ttm~,?3/''~:~o:Rc.E· . . . //.~~.:~ ; .. ~~ :::-·: -~ ~~;.,;/::·· ---· \·:-> t ,.~ .. \'.-~~,-~-:·t:~~-~:··: ~,-.... ~}:\/_~r::.·/._{::.~_t/-.:, ~-'-·_ ._.~-::-· -_-. -. > ; -. --_ -. : . -·. ~ · -., , .... · ··_; :" · -: ..,-.,> :-~. .._., _. __ . . -· · ··" .. :. '· .. ,< . .-_ '::, ·-.. _.. :·.,.~ J.,. :: · : , .. · ·. . · " · · , RECt::IVEO· f EB 2 1 ·1991 . · ·:· .. , _'. ~I!~(q~>,~~rl§ID~( ::(·:/.<· _. .:_~ '·.},,>_,->/ _ ·-· .. :.:r ·· G;tx -C:?fCq,;flsbad, FIFe Departrnen_t _. ·,.::; '.=>>-:207S~&{f~liri'1~Pr{i~·-:~·t.:.~_:r,.:'.:,.-c.'-;.,-.--.. ~'_;··:·:2s_6Q;:Orion.Way"_· .. · · ._ :· .· : :<:.;.-·:·. ' .,"_; J3~:tl_sbaq{CA'cj>iQ08(~-:::--:~/:-:·::'\·:c.~~-~,---. ~:' \'.t ·.:~._:__. I ;J)arlso.~d;'' CA-· 9~0.98 : • ' ····: •" h •• .Bear .Mf. .. -·Oranyak,~-;Mr .. --srmth-., .. ·:· .. ., ' <··· '··. ',•' .. L':° . .' ,. . ;·,._:>. __ -./ ... __ :~-/:~-/~~t:.}\,~,~<-._;· ~:::.-~t)·1/"))-:/~~,~T\~·>, _.,:·\~?/\) .:·t/-::/_~~----_\ _· ··. · , . . <-. . . : ... _.~;:, : .. ,-"~·:-:)W~:'.~~y~_?1:evi~~ed"~P-e.' ~~qti~¢Ilt~rits :QL~---i9-a9-.-~sJt tH~t~s Jo ~ujldings ·A_ & C at L3:s . : . '/::·.1.;.-:-~· ; __ t· ~ :,_ ··c V.ill~f de:,~_a:'i:lsb~cttJ1}~}0J.lt-:h.11'i!~rsia~91~g=·~Ji~(~.~uil<.\higJ1:~wsing non-amoulatqcy _persons .·_; ::-r:-.~::~: :· ·.; -~ ·:{ Qit_': -~P,~:: se~'.9:ri~;:-~o_QJ; :;ajusfJ?~/lly,p_~ 'Y,/gµ~)1q1:1:f':: .c~.rtshµctio11, :: anq C be-fire sprinklered . . ;· ... ,.: :<\:<~ \-)?[P,rig~~?f~~a~t·bi;qan¢e ~{~::-~ )9~?-.:.~-·-·ilpfef.q~i_ti,~~,--w:~--~~ye_._read :r<;urt Culver's (Esgi! ~ · .':. ---~ .. _,.;_:: ·\ ·.;Cot-p'0.taJipn}'lett~t--d~feff\f~bwc,1:ty-:~ti/ :l99f~~\'i<;twilltr:esp0nd:. to· pis <;:onc~rns about the· :~ ::~:'_~ · ,-:·· ;i,_:='>'-~,-:_:ovi~1#it_1:g:~¢0J?StfuctroJJ~ wititprqposiqiJ.Iigtiw.;c~tfori~:1;0·-.11;i.~ --~xiit~ng:c0nstI1;1ction. ~or ease of :. ;(: . ·;.;::~ ... ·{\~f:e_a~ijg -:'fie_ :will,:ttist_ ;fi,is;, ~~itqe_t~. witl{gi'.ift~piy.: j~eqi~td_iy {ollowing .... .'. . . . ' : , ,~~ -:i: ).:<\?,.I~:~~~~~t-!\?\ ·.: --~<jr·/~/::X-~_).-·:}\-~~tt:\~~-.<:~-:>·.:~-:\:_-~ --~:( > · -· .. :·-.· ~--: _ ... _-___ :· : · -\:~~-\~t~./··;;~:;i~;-~~~~\:r~il~-.~~~e;:s~o~-~tli)/i':·-~~1l:' .. \#~~i#~hii;~aJi ~n be requir~d to achiev~ ;,. ·, •• r , " .. •• ., -·o· n' ;_1,;·ou· r' -c' on' s·tr·uct1··o··n ., , .. ' ... ~-'.; '>: : .·.' i· ·'e\ ,; , ·, • :.-. · • ' · ' • . . · . ~ -.. : -·... ~ ,.J ~ :· .. -: ...... :11; ~. -;•, . . ' -~ . ,.J '.:--... ..!",,,:, • _!-: , •' •. : · ., -... , .. 1... ·..,·,... ~ ~ -,. "' ._~ ~ . . ~ ; . . . ' ' .,· ;:; ::?r?~~i.J\J\;'f:i}Vt ::c:(?·}/:;tt{T:<·< .;.·.i. ·•. • .. ·'·. . · · •. : ;.:.:_'..-<:.-: _ .. ;::~\Alth.~µgh(th,e:·.qrigih,_@il'it:ns'q:,eq~ii:~d)l2'!.'.gypsul)t qo~rd nri -2x-framing @_ 16" ·o.c. for. all ~~ > t} -..,_ ,-,.._-"•"1,"-•~? ~ ~ ~·-1' "• '' * ,._,• '•/•-J "-~, ..... I·-"-T -,.• '"" ~'J -•• • <· .. :.::· <. ::·/ :,, .... ~P.~f;~t~_q)v~lJ'si-~~~-:J~ptµc1fwaµ:,-p~~ffuc.ti~B,' ~as<dQ'rrfwitp: · Z:x Jraming with ,5 /8" gypsum _ . 5 ": __ ;_:: ')" <-~~·::'12q~iii_l)~9if~h'o\J;~~--::J~~,>re~1;1fr.~Q.~)W..~liff pt;.c.9,~id_g~~~' $1).a~ts,-.. ~nd &~a!r -e~1dqsures· wete _·. ;_~:} :~ :_-:· ::= __ ;· E~/< ·~"?flS~tpt~~t-4·'!.~;~ttf~¥!1$/~)1~ ft:8'~:typ·~/XJ:~,sp'.~ ~~-a~d).. -ln convets~tip_ns ~ith gypsµm : ·· . .' ;· .. _,:~-:· >, ·':-j_·l)_o~td' Jli}ttiufactutets -~n:r.l ~wcLStt)'.q~.O,::•W~oh~v.~ -lea;rjied0'.that p_oiH:;ated. $/8" ·gypsum, boaF_d · --r.,.i.;. 1,.,... .-. ;,-• _ )·..: ... .),· .-,_., .,.,,. __ ••••• ~-,. _ ... -,.,.~ __ ,..,_..,. '; .,,.,.? ."-~t~.-·.,. •· •., .. ~~ ' , _ .... . <: :·.:_ · .. :_'. '. '._.:f<~::Ji~f.:~t?r}?~e)?:}'!_laP.~t~£ti)r~J1)~_:'1h(-last-'t~~j~<;wrs.~. 'Yl_~e-sp,spe~r tpe· ,gyp&uin ~_bard -used. for· ; . -·· ::-." 1 __ ;. ;' ,,:.-.:-. '.>watt~<:itlsJ(trctfQti~a;fVjlla~:matR~: 5}8''.· typ~f',~-~-~, A-v:isu.al-test sb.oul<,1. be ~ade to: _verify the . :,i,~' .'.~;::}!t1~i~t[?;tK1~~:S~0 II}t?{f }('': ,' ~ .• _ . . .• . . ,. • .· .. •· . · .. , · --? ./. :. · ~,) t~;:; .~:~· :~;:.:-~~ Jfl9;ot~¢eµj,~g/~s~~~~lf ;_i~·1: :~~p.~{~~!J.\:·t~gµt?r-.· 1/Z'' ·c1,~~ill ~t: tlie_ .~eili:p.g. _ A11· . -· . ;·\·::_-._·:--,'· :a~~eiybU~s :we.-~t~ .invat~ -0f.,1J~qµJr,~')h¢:-~~all t~(.-be Fife·-Code C .("Type X")~ It .appear~ -l -·- .'• . ' ' ' . ~' .-. :)::-.;:3'-f 111-}it ,ad_dif;io:P,~. -'d.fywiJil3fil)/b~' i~'q'.liirJ~~/:'< ~d r'.: :<·· '::. ,: . _-,·.. ,. . ' \',{\~~~}tt}:{;}{:;}f:f ;'.Vi_.~ h:if \(f i}):::fBI'~ ~: .••.• ' ..•. ·.· ...•. · '. . . .. '· · ·:·. ,.. -.. "_, .. " .... , '· :,;· .,, ---~~.:-, ,, :: .·· · , .. _,. ,. S I'L L·M.-A:N·/ W YM·-'A-N-· I~ C · ·· , ., · //, , r ::}}j 1;1:,f il~\J?~JJ.·l~'.'~t~}1(t ff <;: E:, :, . ~· 1 ·. N E -.E. R I N . G ; ... _; "·, .. t :·. }:' < --> > ;9699·~~piis:~$tr\!~t; ~~ite_ +_:90/§a~J;>:tegci;-t~Hfoihi~_9~I~f-~ QEf\Cf:.(619) 45~-4320,.FAX (.619) 552'-1563 · ·. ·.-·. _. --~ .,,,. :.;;:··,•.' ,:·· ·,,· ;,:·c,,·.. .:_.J;~rr-y .. J~-:§illqi;ip:,.A..I:A,,.Arcnitecta.-Bruc;:e.H. Wyman,R.C.E. ' .· ; "\, '. \:tt;. }~\\{~,:. ,_, tF:tr/\~'\'#tfJ?"t'.< . .. . . . . . . .. . . . I •· :I ·., ..... , ,.., <I. • · .. ·' ' ~ , ,. ~· • • !_ ~. ' ' ," ' -:-·::· :,,-:/t:-:·ti):.::~;.~:::.Ji1ease~refer<fo,ith:e·.:r~ply;-icrit'e:ms·.#2~ind':#'s.:-·. -·. :" ·. ·.-.. . : ·. -, . ; :/ , . ·. ': :~: :.): ?)if}'~: ;'we pt'Jp~se·. }httt . ._fh~;ar,~~~;pf .·t~~)1~n~Jiig:;$hiilt-l:>.e:siich·-lli~t the 'SUID, ~f th'e · ratios:·· of ·--?>: -~; : ..... : ,·::-,-~-~\-'·:~:r-tli~;ict\ia;l,-~f~~:_fpi:~~~a6J(~~:p~r~fr~:9pqrip~~~>:4iY-id~Q_'.by the total arlo'\\'.'atil~. area for ,/·:-·:, '.' :-:.· ;::".''_, ... ::,.·-,a,· .. ' ;'·fi\!l'' .. · • -t ·,.'·.' .. :.-.-, .· .. •.,,c;_:;,: 1··1··. :·.:~:-'.,·,'.'·, ::,c1:• ... ,·• .. ·:, , .. ,, ·:_, ·. ·.. : . ' . -.-.. , ... ,-.. ,, .. ,.,, .. _.:···~ .:.--•eac ~,sepa.ra e .. occupanq.,,su:a -noL~.exce.eu .. one.· , ... --: , . · .. . . . _\; t' \>' ;'t > ;-}:}ltj{{:-~ti~fe#f ~t}~~~c~4P)i.*fiP4iY.gl{giif :W~f ~d\tcgr:rictdfs· fs 16 p_roride tor the s.~fe ·: < ·?·~·-. ·,._ i ,_.? .·:,: ::-:>-.)/, ;4'.~$9yat~f-~~tiy~1~-:::w,4o ~:ar~-;'.~l:ieptlcluejj'\7::13y· the -h#ure o{ the--~icensing-of tliis /. \· ~ ::-. f _· .. :. ~·::·,._:_'\}/ Jt.oi!ity,,. l?-~ijrlqo~n/pi,tients-= ai(p0t= al1,o~e~l-1o:--;Be'··]1ouse4 'in-:thfa.building. . . · ·,··. <--~---. ~\(tfv} ~>\~:~e\pi9_p9§ftp,pr9vi9,e:p}iIµ~·~ai&~a'.t(is:.ieqµµ:e,do;n.exit d_oors.. . .. · --· )>· :} ;~ t:·(~'iif_-~;~;_:=Y~~\ ·f}j~~:}ti~e'j)t~~{Q~~m}i t~~]:~?~~:t#it7,:·'.l?-~f?-: }~~-~b:~c :-an~ the ·s_tate~adopted - '.\·· · .:· : : -.:·:., · ._.-,, :: .·, '.. · .;pJ~bmg-: c;_qc;l~; ;~1.1-p~ed :· .. th.e: ~~se:, pf-..-,~0~;.µi_~talhc_. ·pipe~ We, propose that the .: :· > ·---~-'-< ·. · -~';jr),:_:.·\: >:::) cqp:s~c.ti_£iii: <?$' 1'4~ ~tl.ij4fag: .i0µ1~'li~~~,~f~: 't~1t(~ode ·4i ftirce at" ·tha,t tirp.e-and tha~ ";,, '• }' ... "• ::,,•.-:·J:•."'"l,·,:\.C,:a..,;the'·r'c·' ''•TI" ·w'·'· '. ••Tl',:Sd':,:: ;V;•,'.tn :_•;•-:, :-,,. ,, . • ' , ·.,·.-·. _ · -: _.-,.:->· ,·· _ :~: -:: :_,:--:+~.--.,__. -: .<]WP ... ~~~e .. a;_s--w~1:~~ >_·-~::·'. -.... _. , __ ~ ·-; ;._-· ,_ J -•. :· ~-. • . . -·• _ . . -_ _ ::~ _ .-, : : ~" \~-_. . _· :,~)\\:·: ·We,·:ha,ye-iioi'.:r~c~iypf:l '~a··:copy,, 6(ib~f~ ilccirpi~~. :qowever, we would like tff· review i-.:·,_::~\:<-, ;-::.:: ~;~· :\:·:~-~·::tires~~ <fofiirtlenfs:<aria-:i-esp0ud~'.to·:tliefu.-as;s0.dn"ias' pos'sibie-. · · -. . · . · -· . ;~\-··;t?,~~;~~~.\J/f},1.:;/f\.{f:t;A:;:{I'.. /; ·. ·• .·· •. ·.. .• ·.•·· .·· .. · .· · .. . · · .. ~_::,_-,-_ .:_'. · :_:\ ~·./~~:· .. ;,.\.In: '.~~l~(Z4,,, :~!(~.)111cro-1>;it;:~ut;.:~it((lj~t_ ~U:st ~~~-:accessible_ for the· dtsa"bl~.d is much :··-::,_ <:_ :· i· · :: ,: :, ~-:::_:::-··:::/Jiigb'.er:f9~?.J~ ·.opcµ.J.)!(~c(e~jlianf."J{(Jtogciipancies; .'F(;)r Jhe. "I" occupail~_ies·, 10% of ;I' •'•I ~,,..1~• ~,-,.-:--, .. ra.:,· .. -.~,_ .~.,-• __ .... :,• ;. :~,'".._•~,,,.,., ,-'-,;: .,_:•~ ~"',-•.:: :--1'" • 'L•,:-~ ,.,,r,• ', ~ • • ' • • .-: ,: · .:,.J·· ·,; c_..·:·,-tue.-,units,'-must:compJy~, ---..v,-:.:·.-s .. ''-.; ·-,:·',-,. ·:-·:· ~ ' :·· .. '. · --. -· ~;/t?}?i~i~J:;'i/)Y';:'}{tt1}:i:f:/{?J''. .·.·{ .,· ... · . • .• ·.. · .· .• ~--':: -.";)·/?: -~ / ;'~JJ: 0{ tijf :epS·t})l_g::iwlth~r¢Ji~~a{~a1{~c~es.Sibl¢;aD,Q, ·p.aYt J?eeij. designed-tO be handicap ' ~~'-_ \,(/·{-~~·rtt~\?~!i~~\Et:~~/:t·:~~~\;:_-~ .. -ti: ~:·_;:/D.f ~(~:{'.t;~/:··~:<---/-:::~--_-·:;~_ .. --.. : -· -... : · ---. · ·. · . _,:-:-,. .' · .?\\·: :Jh-)!aqitiort)o\W:~Gajv~tis/~o;ioi:ttjs,;w~:.-;would .. :a1sQ:P¥9P-os~ · the f9Jimyiq.g to comply. with )( -:~(;)--: f ~:-j\~~f.t~·~i:·.r_'.)::~,J::~_·:~~_i/\\)\/;~_;~~---t-~}~{}};{:j/~;~:::::: / ~-~:. • ... ·_.· -·_. . . ' .-. . . :: , __ ~-:_" .. ~-:,:~~ :\~};~:-z_}~~j~itW/~t~~~fr/~r \~µ/~:~i1i. :~kp~s~1~---:~wr~~~il:f:~~-~npp:u_t~ rated cfooi:s acr9ss the ,/ .'-~-;·_ ., '~ :~·_,'.·?-' ''.. ; . ~::~-:~C!}rt14ot: prrt4¢l_s~qo!]-d::;flb.q:1;-f of:BJ:lild~g:_{;;' --~s,-w0ul<:l. l\Ii-riJ th~ .ind~vidual ,are~_s of ' :.( <-;-_: -~,~ -~ ::_.J:' ·s.:}::.\~ ·: -~lteJ?-~Jt~girtR-,cie&s)h:'~iJ\~~~qo9; ·tf., ~lt~:;i51,9~9e: t~~ r~quirect sm0k~ b~rrier. These· -~ ·:; ~::;';,; ,; :. /.' ::·<;_::~_ ;./ --<·sJJio~~-.\4lfqrs.::.s~~tj19t)?e.,~q~atet.f gµj~tly,.~~oy~ ;t_~e-.-sm~ke -do(?rs_ .at t~e: first ~oqr. :-'"-~ ·~:~:.":-... ~_ .. ~\~~·\;~.:_-~,:~\: .7·<,.t.t·:·-~::~::~ :<·.~.2-~--~·::=:-~-~ .. ~--~<,'f;"',,;_,-!i~~.-~:::')'./•,t~~-~ .. ::.:::~: ': · .. -~~---. . ' --- .::_·. '.·~: .· '-~.!i~/ .. 'i~·_;;).:.~~tli~:hrrit~::~j{d:· th~-t~tn.ili~tl~~r~·as~~tlix~iiil~(~on:tain"_strioke c:Ietectors._: We propo·se-. ;:. : ~~ :: · ::; \:-'_/ ::' .·. :~: / ~:ih~st}'-cij_tlgt~i/fB~',wi_i~ii--'ba:t:l(tq ·tlie:.:~¢i~µcfator paneL · . ··. . . . · · · :.:~-::::·s.}~-:_\:· .:·._::;·_;:_-/~i:> f~ .:\.:-:t-./:'l;.-<::::-i/'.;:~";:::(,{_~_.·rit ·J/L->i;~:··/:::~/?:) > ·;: ·. ·::.~ -· ·. · . · . .-_ : ·. . . _ ·. :: \<. .~-:. -·::; \ <Y'·Wl belief~ :ih€la;boy~\m6tli:£ic~tfbnSiclntl/tji!/t~-#stfug-:cori.4Itions wouldpiovid~ a.building that · ,-,,: ,. \.., '",. ,- .: .-' :~ ··. ~' - ,•,, '. ,_! ,' ,_ : . ,.. ~. - -., :_ ~ ~-'' '• V .... -~ ,••' --. ':: -._.,., , : : '~f,• _i· ·, • ,,, ·. !, ~i:,..---; 1·•:-.·1· -.. ·, ., ;--_, ·.,.:;, ':,,( ,. ~:JJ;g::-s~anze;:~tlie--0µ._11{11'.l;l.gs: w.01:11d:;__ : ·:·,.,.,\ ;·--::.::,. -. · ~---· · '..J:. /·,:·~:\-/f\-'{~:~:{f \,· '1}~/}<)_(:.·_:.:·_,.5,,--///,:~-t~\~j:t_.~}{\:,__~-/: _: ~.~,· ,;·_y-:· ._ . \-:,;.fy:-, :,--'--~e Jype Yl/P_nef'lioµr -~R:t;r§ttµ.Qt~Olf.;,tpr9u.gh0ut. ·: , . , .. _ -. '\" ··':·-·.,:,:t-~--/?\/,_:)}t>-·-\·::·:.::~;--··:/)~ -/:~/~J<_;_';~;·:.\~;:·~:~-<~~) ·-:·:,'.'_-·_-:··· ;_ ; .. -., . . . . . . :~-: · ._, )B.:~. · :, :;~1:J:aye .iilS.t~IJetl· a, -St-ate ;tire :tnafsn.aJI;~ppr6~e.tLa~4 lJst~-a automatic fire ex#nguishing }/':, ·. :<'I\\";?fW~!~~~~\~".;:/tYf{;)?i7:\· ) i , : · .·. . . . . . ·. : _,~ ;-; -. ---~---~ . .:'" >-~ o.:: ·.:-'-·:;. Jj;lxe·'a~:~ne:~Ji9µr:ta.t.~·,;ko¢~\i'.y_a,i~i ~~paf~fL01i,-~pri:I' Jh~-·6X.istirig R-i ·occupancy to. the /~:'.>·· .·. // ::/-.::"-.~~ ,·,:<_ . ., -'.propb~e'{}__ .. b:ccripancy/·:-f•/6··.~ ·,/::,,; .. t>-.. _-_-: :· · .. : ,<' ·': :,~ ,_ --~ · , · . . . --/ :-.:-. ·· ·-·-::.-::~::·.r .. ·-j~·;':<}i ?·:/~-::.-:_ .l:-:-_ .. ,·~.,-t~:y:_)\-'.>::'.\~~.-)~--~:t>-> \: ,.._<-' ·-__ -__ . ·_ · ---· ----. . ,-_ ': 1.-<·. ~\ i'.:l?:':,_./ :_~$<J:ve~ii?,stil{~e; ctSt~t~;·Eiie:Mw§liiriFa:p.pri1:v:i~,ap.d_liifted ·automatic £he alarm system. ~-~-.> '.,:·:·,:_-~--.:_:·;,~·,:_;~-~~:~\->}/,\f:'\;_.:·/\?/\./;-::-.:.~;(?-'-,/)-.\\·.,.··p-:,-, _.:'G\,:·;~.-; .--·: ... ,. . . -·_ .. c_'. ·... ·--: ·// J~t< : _;· .,J;!(j,\fy· jn4ividgal ffqoi:,a'.J'.;e,?s::{ess::.tlta.ri'q;OQ~,.,s:,f; :-·. ,.- ;~ •• · :, 2·• :_:{}};;t;~;~}ic~i_Sf }J~~~t~~1~f ~;;jfaJ:. ; ....... ; :,<·:_·:_;: .\}:/~!/ij2i~clttf~;jJ:.'tii~~~vt· ,t.h¢:if~i~itfil~i~;,d~th:··~tt~ti,cl;~js 24 :hmiFS· a .d~y_providing an ~-.: ·.' ;->t\--} <;.~ve'Ji-:s:aferte:i:J..vir0:nhlent--fo1ftb,e.iesideitt§5;' :\·'. t :,':/· / .,---s---< . -.• . , ~-, :,::_:·:-~_?:, ':}tt)/.~<;.l.'(-~·(\~~}/::~::-_'; ~~::.~~--:_.\.\(;/-;f(;,_:,.://· <~ _\t~\---~ _:~,-;:_·-. · .. :: ~ . :,, : ' . ' -:. _, f:~If-ybij:)[ave'iany-~qu~~tiozjs-\~garqifig·.1;1)i~ :witter,; ;pleas~-.d~.' n:ot liesit.ate to ¢_9ntact me. '~:---' :,,...1';·, .~ / l ,_ .... :..; .... ~-. -- -.· ;, \ -: : -, ":-: .':::_:/ .. : ·:.: .. :ec(: 1:. .. ":.l\fr{:R,op:.:.W-lcEllfot;t/IticdinJ~-:f):'01fot:ty-~rqu1i' . , ;~ •• -: '' c~~ ~ ,' / ~'?-?~(£ ·: ~---/:::M;i-:j<w=t -~}~eirBsjit ObWQ~<iti~t{:/\ '~-·: ": :, --.~ -:,· ': -;.·;:_:: ;L __ J: __ ::,:,~·:_:-:::> ::·.,Mr>Keithc:Rstes/:EsteS-:C0nsh;_udtfoir'Managenieri{ • :~. -7-' ,' ' \ ,:' '' - ··,_1, ;: ...... -:.-r· : j ;:'•_ -: -~~: \'":' ,:-,· .. ,;-;.. ) .... -.5, ~-.. ~: City of Carlsbad . K-l•heh,hhhC41•1M4t•1•ieet4UI February 15, 1991 Mr. Ron Mc Elliott Income Property Group 1060 Eighth Avenue, Ste 405 San Diego, CA 92101 VILLAS DE CARLSBAD Dear Mr. Mc Elliott: Pursuant to your letter of January 24, 1991, requesting a review of Assembly Bill 1989 and how this legislation would apply to upgrading the second story of Villas de Carlsbad to . provide "non-ambulatory" care, the City has completed its initial investigation. Upon review of your original building plans of the second floor, the City, in conjunction with our Code consultant, was able to develop the following list of issues and/or concerns which will need to be addressed by you and your architect: 1. The walls are shown with 1/2" drywall. Additional drywall will be required to achieve one-hour construction. 2. The floor-ceiling assembly is shown with regular 1/2 " drywall at the ceiling. All assemblies will require the drywall to be Fire Code C (Type "X"). It appears that additional drywall will be required. 3. Items 1 and 2, if corrected, will provide sufficient dead load to the structure such that additional design calculations would be needed in order to evaluate the effect. · 4. Furred ceilings, where they occur below the rated floor ceiling assembly, must be constructed of noncombustible materials or fire-retardant treated wood, per UBC section 4203. 5. As an alternative to item 4, if the rated membrane for the ceiling "wraps- around" the furred areas, then neither non-combustible framing nor fire- retardant treated wood would be required. However, by establisl).ing the rated membrane at the bottom and sides of the furred area, fire dampers would be required at all mechanical penetrations there, per UBC Section 4306 (j). Required access panels to the fire dampers may ·also be an issue. 2075 Las Palmas Drive • Carlsbad, California 92009 • (619) 438-1161 t Mc Elliott February 15, 1991 Page 2 6. The third level balconies are shown as covered with "Elasto-Deck". We are unable to identify any ICBO reports, or equal, for this product to achieve one- hour construction. 7. Parts of the floor-ceiling assembly show a suspended ceiling. If this suspended ceiling is to be the one-hour membrane: a. The system must be from an approved manufacturer with a listing to achieve one-hour construction. b. Recessed lights occurring there, would require a drywall "tent" to maintain the rating. c. Mechanical penetrations there, would require fire dampers to maintain the rating. 8. The outside air ducts extending to the roof would be required to be in shafts, per UBC Section 1706(a), (Exception 5 therein does not apply), and to maintain the occupancy separations required between the "I" occupancy and the "R-1" occupancy. 9. There are other incidental detailing requirements typical for one-hour construction: a. The integrity of the one-hour walls must be maintained at medicine cabinets, electrical panels and fire extinguisher cabinets. b. The drywall at one-hour walls must extend behind abutting fixtures such as bath tubs. 10. Since the second story is proposed to be converted to an "I" occupancy, the provisions of UBC Section 502 apply. Specific concerns are as follows: a. UBC Section 503 requires an occupancy separation between the second and third stories. Penetrations of the floor may be an issue, and must be addressed as per UBC Chapter 43. b. The actual area of the building must be compared to the allowable area, per UBC Section 505, considering the mixed occupancies. Mc Elliott February 15, 1991 Page 3 c. UBC Section 3321( c) requires corridors to be eight feet wide. d. Panic hardware will be required per UBC Section 3321(f). e. The plumbing materials must be investigated to verify metal piping was used, per the state-adopted Plumbing Code. f. The electrical wiring must be investigated to verify compliance with the NEC. As previously mentioned, we would suggest your architect verify these items and develop a mitigation strategy. Once these issues have been addressed, please feel free to contact Mike Smith, the City Fire Marshall; at 931-2141, extension 2125. He will be able to facilitate any future meetings with City staff. Sincerely, Community Development Director MO:CH c. Fire Marshall DEVELOPMENT• CONSTRUCTION SYNDICATING • LEASING • MANAGEMENT WE DEVELOP AND CONSTRUCT BUILDINGS THAT WORK FOR A LIVING 1060 EIGHTH AVENUE SUITE405 . SAN DIEGO, CA 92101 (619) 234-4316 11 IJ INCOME PROPERTY GROUP VILLAS DE CARLSBAD, LTD. Mr. Mike Smith, Fire Marshal City of Carlsbad 2560 Orion Way Carlsbad, CA 92008 Re: Non-Ambulatory Occupancy Approval Las Villas de Carlsbad 1088 Laguna Drive Gentlemen: January 24, 1991 Mr. Martin Oreriyak, Bldg. Official City of Carlsbad 2075 Las Palmas Drive· Carlsbad, CA 92009 In 1987 we completed construction and opened Las Villas de Carlsbad as a 153 unit residential care facility for the elderly (RCFE). We continue to own and operate this- very nice complex. Because of the "aging in place" phenomena and the fact.that the average age of our residents increases annually, we have found that there is a tremendous need within our facility to offer another level of care called assisted living. Before the Department of Social Services, State of California, will isuue a license for an assisted living unit . (ALU), the local fire marshal must allow non-ambulatory occupancy in those areas to be licensed. As you know, we are currently licensed as an ALU on the ground floors of Buildings A & C. Although our capacity and approval is for 49 non"'arribulatory occupants in these two areas, we are currently at maximum occupancy with a total of only 26 residents (many double occupancy rooms with ·single resident). · · · The demand for assisted living care ·is tremendous. We need more ALU's at Las Villas de Carlsbad to accomodate our existing residents as well as new. It is our belief, with the advent of AB 1989, that we can now qµalify· for non-ambulatory occupancy on the second floors of Buildings A & C, double our ALU's, and satisfy our need. · Mr. Jim Roemen, Sillman/Wyman & Associates, and myself met last week with -1 ! Mr. Mike Smith Mr. Martin Oronyak January 24, 1991 Page Two Curt Culver at Esgil. It was Mr. Culver's opinion that we needed to make a few modifications to each building in order to conform. Originally, Bli!ildings A & C were constructed as Type 5, one hour with the assistance of fire sprinklers. ,1 now feel comfortable that we can achieve the Type 5, one hour condition without the help of the fire sprinklers and therefore comply with the conditions of AB 1989. I have enclosed for your information a package of inf9rmation frotn the California State Fire Marshal's office. It includes a copy of AB .1989 and a series of questions and answers. I specifically direct you to questions 5.A and -8.A. I would like to arrange a joint meeting as soon a possible to discuss our request. I will contact you next week. · Thank you for your consideration. Enclosure RJM/ws Very truly yours, VILLAS DE CARLSBAD, LTD. Ronald J. McEUiott B U I L D I N G P E R M I T PCR No: PCR92030 Project No: A9101214 Development No: 06/11/92 15:18 Page 1 of 1 Job Address: 1088 LAGUNA DR Suite: Permit Type: PLAN CHECK REVISION Parcel No: 155-272-19-00 Valuation: O Construction Type: NEW Lot#: 8037 06/11/92 0001 01 C-PRMT Occupancy Group: Reference#: 91-986 Status: Description: RELOCATE BATH/REMODEL STORERM Applied: Apr/Issue: Validated By: 619 234-4316 7 FINAL APPROVAL 02 163-00 ISSUED 05/18/92 06/11/92 SBB INSP. __ DATE _ _. CLEARANCE ____ _. CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 DATE: ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DI :EGO, CA 92 I 23 (619) 560-1468 JURISDICTIO JURISDICTION: . Ca c/15 heel PLAN CHECKER OFILE COPY QUPS ODESIGNER PLAN CHECK NO: SET: 7T; PROJECT ADDRESS: /0&$ Layuae Q c':· PROJECT NAME= Sfu,ce,reoro l&+ticrz<?nq 4Lna?d~/ D D D 0 The plans transmitted herewith have been corrected where necessary and substantially comply wi tl;l the jurisdiction's-·-.. building codes. · The plans transmitted herewith will supstantially comply with the jurisdiction's puilding codes when minor deficien- cies identified-----------------are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applica~t contact person. O The applicant's copy of the check list has been sent to: --""'----·---1: ~ Esgil s·taff did not ad.vise the applic:a,r,yt,. contact person that plan check has been completed. O Esgil staff did advise applicant that :.the plan check has been completed. P~rson contacted: --,.----------- Date contacted: Telephone i ---------------------~ REMARKS:. /\J 0 ±e, lj 00 sbe:e+ A si< b<={.s been arn1±h·d 7111':;s ;:;,b:?<& /,,t bL ve:c,'.£; c: d ,aitb ±be I . By: £dt2Jver ESGIL C0RP0RAT'ION l;j Enclosures: Ca±y-etJ~,-,,..v.ecf o}q..y,.-, r, . I 0GA ·OcM DATE: ESGlL CORPORATION - 9320 CHESAPEAKE DR., SUITE 208 SAN DIE.GO, CA 92123 (619) 560-1468 JURISDICTION: CARLSBAD JURISDICTI N PLAN. CHECKER OFILE COPY OUPS QDESIGNER PLAN-CHECK NO: 9 I-9 $l" RE\/ SET: I PROJECT ADDRESS: · 10m, L~u.n~ De PROJECT NAME:· S:bce.x:::o<2M-/B.::..+t,.c,;,,:pm, Red()/) ao{ « l D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the .jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's ·building codes when minor deficien- cies identified ---------'--------'--are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for·a complete recheck . . -~ The check list transmitted herewith is fo-r your information. ~ The plans are being held at Esgil" Corp. until corrected plans are submitted for recheck. -.D The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant·contact person. ~ The_ appl_icant·'_s copy. of the check ~ist has been · sent to: . _ Yi lie:;, k c~,uc:l:r,~eel (0toO ~ A-v~,) #: 405 .,•:. 50iM D, 'd O er a I oJ .. , . ~ Esgil staf·f did not advise the applicant contact person that plan check has been .completed . . O Esgil staff did advise applicant that the plan check has been completed. Person contacted-: ___________ _ Date contacted: _________ _._ Telephone# _______ _ 0 _REMARKS: _______ _.__ ___ __,-___________ _ .. -, ,~ By:· £art~ ESGILCORP0RATION · s/1,,( Enclosures: ----------- OGA DcM l PLAH CHECK NO. : _ _;9..:.l-....a._'1 ..... <8:;....,4,..._·KE~ ... v'--· ------- JURISDIC'IIOH:_ . ...:CARLSBAD===------------ m: ___ V~: _;_t\_~_s----c)...,_ ___ G~~-c~'~=b __ qd__.=-=-- PROJECT DATA OCCUPANCY: __ ...:;r=..:./_:.K_---' _________ _ BUILDING USE: ____ C_a'--'-'rG:::~ .... k___,__""'C._/ .... /t~t/------- TYPE OF COHS'.IXUC'IlOH: ___ 'ffi......_..._\ .... :;,s ___ --e._.o(..._....__ ____ _ ACIUAL-ARF.A: ____ /J.......,./ __ s:,,-. ______ _ ,AJ.IDiiABLE ARF.A: ___ .,_N ..... · ~le--<.__ _____ _ Sl'ORIES: ______ tv ___ { __ c.,... ______ _ HEI~: _______ __.,N ........ ,__ __________ ---'_ SPRIHKLERS: ___ ---,-,rJ<.:-.:.f~,------- OCCOPAH'i LOAD:. ____ ,,,..,,___,AJ..:;....:..;I C---=-------- REMARKS:..,.... _____ __. _____ ..,.._ ____ _,,,_ Date plans received by jurisdiction: Date plans received by Esgil Corporation: s/z.i/qz Date initial plan check completed: ___ s .... -..... !2&.___.{ ...... q __ 2--___ By:_~~-j ..... r_+~C-f ..... l ...... ,ce_,.-,-_ Applicant contact person: _ _______ T.el. .9. 3 '-I-'-f:,:, I?, FORF.WRD: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Code sections cited are based on.the 1988 UBC. The circled items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance· with the cited codes and regulations. Per Sec. 3O3(c), 1988 Uniform Building Code, the approval of the plans ~oes not permit the violation of any state, county or city law. To speed up the recheck process, note on this list (or a copy) where each correction item-has been addressed, i.e., ·plan sheet,_ specification. etc. Be sure to enclose the marked up list when you submit the revised plans. NOIE: PAGE HDMBERS ARE IfO'J: IK SEQOENCE AS PAGES HAVIIC NO IDHS :NEEDING CORRECIIOHS WERE DELEIED. LIST NO. 56 CARL$BAD TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1988 UBC tV Please make all corrections on the original V .tracings· and submit two new ·sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: I· I· I· /· f /· Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-1468. Please make all corrections on ·the Qriginal tracings and submit two new sets·of prints, and any original plan sets t;.hat may have been returned to you by the jurisdiction, to: The jurisdiction's building department. Indicate on the Iitle Sheet of the plans, the name of the lega~ own_e., and name _. of person responsible for the preparation of the plan~. Section 302(d). · · -: - Each·sheet of the plans must be signed by the ,person responsible for their preparation., even though there are no structural changes. Business and Professions Code. Plans and calculations shall be signed by the California state licensed engineer or architect where there are structural changes to existing buildings or structural ad9itions. Please include the California license number, seal, date of license expiratiop and date plans are signed. Business and Professions Code. Provide the correct address and suite number of tenant space on the plans. Section 3.02(d). Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled. Section 302. When the character of the occupancy or use changes within a ·building, the building must be made to comply with .current Building Code requirements for the new occupancy. Please provide complete .details to show the building with comply. Section 502. UBC Section 304 requires the Building Official to determine the total value of all construction work proposed under this permit. The value· shall include al,l finish work, . . painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment. Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed. Provide a plot·plan showing·the distance from the building to the property lines and the · location of tenant· space (or remodel) within the building. 7/10/91 f· On the first sheet of the plans indicate: Iype of construction of the existing building, present and proposed occupancy classifications ·of the remodel area and the occupant load of the remodel areas and the floor where the tenant improvement is located. Provide-a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 9-A and 9-B. A complete description of the activities and processes that will occur in this tenant space should be provided. A listing of all hazardous materials should be included. Ihe · materials listing should be stated in a form that would make classification in Tables 9-A and 9-B. possible. The building official may require a technical report to identify and devel9p methods of protection from hazardous materials. S~ction 90l(f). If control areas are used for exceeding the exempt amounts of hazardous materials from Iables 9-A and 9-B, they shall be constructed of not less that required for a one-hour occupancy separation •. Section 404. The number of control areas within a building used for retail/wholesale stores shall not exceed two; the number of control areas in buildings with other uses shall not exceed four. Footnote 1, Tables 9-A and 9-B. The aggregate quantity of any hazardous materials "in use" and "in storage" shall not exceed the quantity li~ted in Iables 9-A and 9-B for "storage". Footnotes 2 and 3, Tables 9-A and 9-B. Provide a statement on the Iitle Sheet of the plans that this project shall comply with Title 24 and 1988 UBC, UMC and UPC and 1990 NEC. Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or ·a1 tered. Draw the plans to scale and indicate the scale on the plan. Section 302(d). Indicate the use of all spaces adjacent to the area being remodeled or improved. Show any existing fire rated area separation walls, occupancy sepaxation. walls, demising walls, shafts or rated corridors. Identify and provide constructi-0n details for proposed new fire rated walls. Specify on the plans the fire ratings of assemblies to protect proposed openings in existing or new fire walls. 2 '. l. Identify existing walls to be removed, existing walls .to remain and proposed new walls. Identify bearing walls., non-bearing walls, and shear walls. ~-Provide a section view of all new interior V partitions. Show: (a) ---(b) (.c) (d) Type, size and spacing of !ituds. gauge for metal studs. manufacturer and approval indicate 11to be ICBO approved11 • Indicate Specify number or Method of attaching@ and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor .framing, unless suspended ceiling has been designed for partition lateral load). Wall 'sheathing -:material and details of attachment (size: ... and spacing of fasteners). Show height of partition ·and suspended ceiling, and height from floor to roof framing or floor framing. Provide notes and'/or details to show that the floor and wall finish in toilet rooms are surfaced with a smooth hard non-absorbent material extending five inches up 'the wall. Similar surfacing ·shall be provide~ on the walls from the floor to a height of 4 feet around urinals and within water closet compartments. Section 510(b). Note on the plans: 11All interior finishes must comply with Chapter 42 of the UBC11• Specify "Class _______ flame spread rating (minimum) 'for---------------II Lateral bracing for suspended ceiiing must be provided. (UBC Table 23-P) Where ceiling is not supporting interior partitions, ceiling bracing shall be provided by four No. 12 gauge wires -secured to the main runner w:i:thin 2 inches of the cross runner intersection and splayed 90 degrees from each other at an angle not.exceeding 45 degrees from the plane of the ceiling. ·A strut (adequate to resist the vertical component from lateral loads) fastened ·to the main runner shall be extended to and fastened to the structural members.of ·the roof or floor above. These .horizontal restraint points shall be placed 12 teet o.c. in both directions with the first point within 6 feet of each wall. Attachment of restraint wires to the structure ab9ve shall be adequate for '.tile load imposed. UBC Standard 47-18. ' ........ 2/15/90 f -t· {o. In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and floor above . so that no concealed space exceeds 1,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 3,000 s.f. and 100 L.F.). Section 2516(f). In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and roof above so that no concealed space exceeds 3,000 s.f. and no horizontal· dimension exceeds 60 L.F. (if space has sprinklers, then 9,000 s.f. and 100 L.F.). Section 2516(f). Stor~ge areas exceeding 1000 sq. ft. in -connection with wholesale or retail sales shall be separated from the public area by a one-hour occupancy separation. If the entire building has an automatic sprinkler system, then the occupancy separation need not be provided. An automatic sprinkler system shall be inst!illed in rooms used by the occupants for the consumption of alcohol and in accessory uses where the total area of such unseparated rooms and assembly uses exceeds 5000 square feet. Section 3802(c). The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. See the attached correction sheet. Title 24, Part 2. The width of the required level area on the side into which doors swing shall extend 24 inches past the strike edge for exterior doors and 18 inches past the strike edge for interior doors. Section 2-3304, Title 24. Specify lever-type hardware for passage doors. on floors accessible to the disabled. Section 2-3304, Title 24. If both sexes will be employed and the number of employees exceeds four, provide separate toilet facilities for men and women. If "both sexes will be employed and the total number of employees will not exceed four11 , and only one restroom is provided, note the words in quotation above on the floor plan. Section 705. In areas where the occupant load exceeds· __ , two exits are required. See _______ _ Table 33-A. 3 3f· t· +· 4~. Provide an exit analysis plan (may be 8 1/211 x 1111 -or any convenient size). Exits should have a.minimum separation·of one- half the maximum overall diagonal dimension of the building or area served. ·section 3303(c). The maximum number of required exits ang their required separation must be maintained until egress is provided from the structure. Section 3303(a). Rooms with more than 10 occupants may have .Qlli! exit through .Qlli! adjoining room. Revise exits to comply. Section 3303(e). Exit signs are required for exits serving an occupant load .exc~eding 49. Show all required exit sign locations·. Section 3314(a). Show that exits are lightelwith at least one foot candle at floor level. ·$ecti~n 3313(a). · . Show the locations of existing exits from the building and show the path of travel from the remode_l area to the existing exits. Note on the plans: "All exits are to be openable from inside without the use of a.key or special .knowledge". In lieu of the above, in a Group B occupancy, y9u may note "Provide a sign on or near the exit doors reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS". This signage is only allowed at the main exit. Section 3304(c). Exit doors should be a minimum size of 3 feet by 6 feet 8 inches with a minimum door swing of 90 degrees. Maximum leaf width is 4 feet. Section 3304(f). Exit doors should swing in the direction of egress when serving an occupant load of 50 or more or when serving any hazardous area. Section 3303(b). Applies to door(s) ___ _ Regardless of occupant load, a floor or landing not more than 1/2 inch below the threshold is required .on each side of an exit door used for · disabled access '(may be 111 maximum where not used for disabled access). Section 3304(i), Poors should not project more than 7 inches into the required corridor widtli _when fully opened, nor more than one-half ·of tlle required corridor width when·in, any position. ,Section 3305(d). Revolving, sliding and overhead doors are not permitted as exit doors if the occupant.load exceeds 9 or the exit door serves a·hazardous· area. Section 3304(h). 2/14/90 t· Exit doors from assembly rooms with 50 or more occupants shall not be provided with a latch or lock unless it is panic hardware. Section 3318. Double acting doors are not allowed when serving a tributary occupant load of more than 100, or when part of a fire assembly, or part of smoke and draft control assemblies or when equipped with panic hardware. Section 3304(b). Corridors must provide continuous protection to· the exterior of the building. Interruptions by an intervening room is not permitted: Foyers, lobbies or reception rooms constructed as required for corridors are not considered intervening rooms. Section 3305. Corridors and exterior exit balconies serving 10 or more occupants must be a minimum 44 inches wide and 7 feet high to the lowest projection. Corridors serving -less than 10 occupants must be a minimum of 36 inches in width. Section 3305(b). When two exits are required, dead end corridors and exit balconies are limited to 20 feet. Section 3305(e). Corridors serving 30 or more occupants shall have walls and ceilings of one-hour construction except: a. Corridors greater than 30 feet wide when the occupants have an exit independent from the corridor. b. Exterior sides balconies. of exterior exit c. Corridor walls and ceilings need not be of fire-resistive construction within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sprinkler system throughout and smoke detectors are installed within the corridor in accordance with their listing. Section 3305 (g). Section 3305(g), Exception 5, cannot be used for non-rated corridors in a fully sprinklered office space if the occupant load in the space exceeds 100. Section 3305(g), Exception 5 does not apply to common corridors where the corridor serves as an exit for non-office areas (manufacturing, warehouse, etc.). 4 r· fo. Section 3305(g), Exception 5 is applicable only for corridors on one floor; the corridors on the lower level(s) must be rated if these lower corridors have openings into them from other levels. If non-rated corridors are used per Section 3305(g), Exe. ~, provide a reference tp the corridors on the floor plan, noting: 1. Corridors are non-rated per Section 3305(g), Exception 5. 2. ·smoke detection system must be listed by the State Fire Marshall and be a supervised. low voltage system. 3. Smoke detectors shall be maximum 30' on center. ' 4. Power supply shall be dedicated branch circuit. Circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly marked FIRE ALARM CIRCUIT CONTROL, with a lock-on device. If a tenant space utilizes Section 3305(g), Exception 5, then that tenant space shall be .separated from adjacent spaces by a demising wall constructed as for a one-hour corridor wall. · Clearly show where the non-rated corridor system terminates and a rated corridor system commences, One-hour fire-rated corridors shall have door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes, except openings ·in interior walls of exterior exit balconies. Doors shall be maintained .self-closing o~ be automatic-closing by action of a smoke detector per Section 4306(p). Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Sect;on 3305(h), Show rated corr'idors, lobbies, reception or foyers cross-hatched on the floor plans. Total area of all openings, except doors, in any portion of an interior corridor, shali not exceed 25 percent of the area-of the corridor wall of the room which it is separating from the corridor. Such openings shall be protected by fixed, approved 1/4 inch thick wired-glass installed-in steel frames. Section 3305(h). 6/13/90 Provide a complete architectural section of the corridor, or exterior exit balcony, showing all fire-resistive materials and details of construction for all floors, walls, ceiling and all penetrations. Section -3305(g). (:~ Show the location of fire dampers. Provide ~fire dampers at duct penetrations of fire- rated occupancy and area separations, shafts and corridor walls and ceilings. Section 4306(j). ® t- r· If a room with an exhaust fan has a door opening into a rated corridor, show how make- up air will be provided to the room. The door cannot be undercut, nor can a louver in the door be provided. Section 3305(h)l. If building exceeds two stories and has an elevator opening into a rated corridor, show how the smoke and draft control provision of Section 3305(h) will be met. Either provide a separated elevator lobby or a second door at the elevator entry meeting the provision. If a second door is provided entry, note that it will be from the car side without special knowledge or effort. at the elevator readily openable a key, tool or Section 5106. Provide evidence of Health Department approval (for restaurants or for tenants using X-ray equipment). When nonflammable supply cylinders for medical gas systems are located inside buildings, they shall be in a separate room or enclosure separated from the rest of.the building by not less than one-hour fire-resistive construction. Doors to the room or enclosure shall be self-closing smoke-and draft-control assemblies having a fire-protection rating of not less than one hour. Rooms shall have at ·least one exterior wall in which there are not less than two vents of not less than 36 square inches in area. One vent shall be within 6 inches of the floor and one shall be within 6 inches of the ceiling. When an exterior wall cannot be provided for the room, automatic sprinklers shall be installed within the room and the room shall be vented to the exterior through ducting contained within a one-hour- rated shaft enclosure. Approved mechanical ventilation shall provide six air changes per hour for the room. Section 702(b)4. 5 sf. ELECIRICAL Submit plan showing location of all panels. Submit panels schedules. Submit electrical load calculations Indicate existing main service size. Indicate existing total main service load. Indicate new additional loads. indicate wiring method, i.e. EMT, metal flex. Show exit signs on the electrical lighting plan(s). As per Section 3313 and 3314 of the 1988 UBC, provide two sources of power to exit _signs.and exft illumination. Provide receptacle(s) within 25 1 of HVAC units. UMC Section 509. Provide multiple switch lighting controls per Title 24, 5319. Provide an electrical plan for the alarm system showing compliance .with criteria described under earlier correction number 58. Provide mechanical ventilation in .all rooms capable of supplying a minimum of 5 cubic feet per ·minute of outside air with a total circulation of not less than 15 cubic feet per minute per occupant. Section 605 and 705, UBC. Provide mechanical plans showing existing and proposed HVAC equipment, ducts and access to equipment. Detail access and working clearances to.HVAC equipment. Cooiing coils or cooling unit~ located in attic or furred space, where damage may result from condensate overflow, shall be provided with an additional water tight pan of corrosion resistant material to catch overflow if primary condensate drain becomes clogged. Section 1205,. UMC. One-hour corridors shall not be used as an integral part of a duct system. This includes the space above a dropped ceiling within the one-hour corridor. UMC _Section 706(b). PLUMBING Provide gas show;ng pipe Section 1219. line plans and lengths and gas calculations, demands. UPC 1/23/92 t· Provide drain, waste and vent plans. Provide water line sizing calculations. UPC Section 1009. Detail how floor drain trap seal is to be maintained. UPC Section 707 (floor drain trap priming). Show P & T valve on water heater and detail drain line route from P & I valve to the exterior. UPC Section 1007(e). Show 1/411 per 1211 slope on drain and waste lines. UPC Section 407. Provide a drinking fountain at each floor level in assembly occupancies (except drinking and dining establishments). UBC Section 605. New water closets and associated flushometer valves, if-any, shall .use no more than 1.6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard All2.19.2, and urinals and associated flushometer valves, if any, shall use no more than one gallon per flush and shall meet performance standards established by the American National Standards Institute Standard All2.19.2. H & S Code, Section 17921.3(b). ~ Provide complete energy design calculations, including all existing design and new energy design for this building. See attached non- residential energy design checklist. For remodels in an existing conditioned space, show that the remodeled space will not use more energy than the existing space or show the remodeled space will conform to latest energy design standards. CITY OF CARLSBAD SUPPLEMEN'r Floor drains must have auto-prime (City Policy). A grease interceptor is required. Show -details complying with City Policy 83-34. Roof mounted equipment must be screened and roof penetrations should be minimized (City Policy 80-6). Condensate drains (dry traps are 1/14/83). must connect to a wet trap not permitted). (Memo Show fans are duct type; City Policy does not permit ductless fans. 6 Romex is not permitted in industrial -or commercial buildings. (City Policy) No wiring is permitted on the roof of a building and wiring on the exterior of a building requires approval by the Building Official. (City Policy). All roof-mounted equipment shall be concealed from view. Provide structural-detailing.for the screening. All panel boards. shall have a minimum 100 amp rating or approved by the Building Official. The minimum· rating of a service disconnect is 100 amperes. The minimum -size conductor to recept~cles and lighting fixt~~s-in conunercial and industrial buildings shall b~ U12 Cu. AC(BX) cable is not allowed in.group A, B, E, H and ,I occupancies. (see Ord.-for -exception) Only tank-type 1,·ater closets , . that , use an average of. 1.6 gallons of water per flush or less, and urinals and associated flushometer valves, that use an average of l gallon of water per flush or less shall be installed in new construction. These provisions shall·apply to existing buildings only when toilets are being replaced in existing bathrooms or installed in new bathrooms. MISCELLANEOUS fuo----:'l·Please _ fiee additional corrections or remarks 'J that follow. ~To,speed up the recheck process, note on this C7 list (or a copy) where each correction item has been addressed, i.e., plan sheet_, note or detail number, -calculation page, etc. (,':;~Please indicate here if any changes have been Qmade to the plan~ that are not a result of ·corrections from this list. If there are other changes, please briefly -describe them and where they are located in the plans. Have c~ges beeri. made. to the plans not resulting from this correction list? Please check. ____ Yes ----~No 1/23/92 NO'.CE: The following provisions are contained in Title 24, Part 2, California Building Code, as adopted and enforced by the State Fire Marshal. They are provided here as a courtesy to assist designers in developing the project documents. All applicable provisions may not necessarily be included. Please direct any questions regarding interpretations of these provisions to the local Fire Department. S-1. Walls of corridors and exterior exit balconies in Group·s A,E,I,R-1 and C Occupancies having an occupant load of more than six persons and in all other occupancies having an occupant load of 30 or more shall be not less than one- hour fire-resistive construction. Section 3305(g)l. S-2. Note on the plans t}1at approved floor-level exit signs shall be provided. This applies to A, E and I occupancies. S-~. Area separation walls shall not be considered to create separate buildings for the purpose of automatic fire-sprinkler system requirements as set forth in Chapter 38. Section SOS(e)6. EXCEP'IION: Buildings separated by continuous area separation walls of four-hour fire- resistive construction without openings. Buildings required to have automatic fire- sprinkler protection as set forth in Section 13113 of the Health and Safety Code (homes for children or the aged) are prohibited from using area separation walls in lieu of automatic fire-sprinkler protection. S-4. In educational occupancies, storage and janitor closets shall be of one-hour fire- resistive construction with openings protected by assemblies having at least a three-fourths- hour fire-resistive rating. Section 802(c). S-5. Section 1807 should be reviewed for all high- rise buildings. S-6. The exception in Section 3318 of the UBC has been revised so as to allow the omission of panic hardware at the main exit in churches (by using signage), only when the occupant load of the church is less than 300. S-7. If emergency warning systems are required, they shall activate a means of warning the hearing impairea. Flashing visual warnings shall have a frequency of not more than 60 flashes per minute. 7 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, .California 92123; telephone number -of 619/560-1468, to ·perform the plan check for your project. If you have any questions regarding these plan c~eck items, please contact._,.----' _____ _ Corporation Thank you. Enclosures: l---------"'------------- 2. __ a,.--.....,.--------------.....,_- 3.·---------~-------------- 1/23/92 @) llf fM /,,,fu-st::-vl-r'on &~ the-5 It' 11 lx:fflrt WI f1i t'CK 31/~ // bE:f¼2:'I. fta..cr"< ±be,' c C&a-t;,-+-ran S 1 alt? w n J add ti, e,,, ½E b@m rea cit~ ?,Nd tbe<t1 c,,.h G v? tN /) & s -I- 8 d. The surface of ramps shall be slip- resistant. 2-3307(g) e. A 6011 intermediate landing is required at maximum . elevation change of 3.011 and 7211 landing at each change of direction (over 30 degrees). 2-3307(d,l) f. Landings are required at top and bottom of ~amps. 2-3307(d.l) g. Bottom landing shall be minimum of 7211 in the direction of travel. Fig. 2-33- llA h. Top landing shall be 6011 x 6011 minimum. 2-3307{d.l) i. When· door swings onto _top landing, minimum depth of landing r~quired is door width plus 4211 • 2-3307 ( d .1.) j. Top landing shall have 6011 min. width when door swings onto the landing, with 2411 on strike side of door at exterior ramp, or 1811 at interior ramp. 2-330,(d,l) k. Ramp. handrails are required on each side of ramp, when slope ~xceeds l in 15. ·2- 3307(e.l) 1. -~ handrails shall be continuous, located 3011-3411 in height -above ramp surface, -with 1211 ·extensions beyond top and bottom, and the ends returned. 2-3307(e.l) m. Handrails shall be 1.-1/411 to 211 cross section, spaced minimum of 1-1/211 from wall. 2-3307(e.l) n. A 211 high curb or wheel guide rail centered 311 ± 111 above ramp surface is required on both sides where not otherwise bounded by walls when tpe ramp exceeds·lO feet in length. 2-3307(h.l) SPECIAL ACCESS LIFTS a. ·tifts may be provided between-levels, in lieu of elevator, when· the vertical .distance between· landings, structural elevator, structural design and safeguards are as allowed by the State of California, Department of Industrial Relations, Division of Occupational Safety and Health •. 2-5107(a) . b. The lift-platform shall be of sufficient size to acco111Dodate a wheelchair (3011x4811). 2-5107(a) c. There shall be a level and clear floor area or landing (.6011x6011) at each level for access to the lift. 2-5107{a) ,. HAZARDS a •. Provide 8011 headroom from walkway surface to any overhanging obstruction. 2-3326{b) b. Headroom of maintained for etc. 2-522(£) s61i minimum shall be walks, corridors, aisles, c. Pr.otruding objects with leading edges between 2711 and 8011 above finished floor shall not protrude more than 411 into walks, corridors, etc. 2-522(£) d. Free standing objects mounted on posts between 27 11 and 8011 above the floor may project a maximum of 1211 • 2-522(f) e. Abrupt · changes in level exceeding 411 adjacent to walks, except between walks ·and adjacent streets or drives, shall be identified by 611 high warning curbs above walk surface. 2-3326(a) 0 ENTRANCES, DOORS, VESTIBULES AND CORRIDORS I-All.primary entrances to buildings shall be accessible to the handicapped. 2-330l{f) -{ All required passage doors shall have 3211 clear opening at 90 degrees {3611 door~. ·2-3304(£) At least one of a pair of doors shall meet the minimum 3211 clear entrance width requirement. 2-3304(f) Threshold shall be no higher than 1/211 above the floor. Edge to be beveled with a slope no greater than 1 in 2, if more than 1/411 • 3304{i.l) e/. Exterior level landing may slope .up to / 1/411 per. foot in any direction for surface drainage. 2-413 1-Door hardware shall be of the lever or push type, mounted 3011 to 4411 above the floor and be operable with a maximum effort of 8,5 lbs. for exterior doors and 5 lbs. for interior doors. 2-3304{c), 2- 3304(i.2) J The lower 1011 of the door shall be of ;· smooth, plane surface (no recess or trap) except at automatic and sliding doors. 2-3304(i.3) Building entrance(s) shall be identified by sign with the International Symbol of Accessibility. Show location on plan. The symbol shall be a white figure on blue background. 2-522(b) {1. At turnstile, provide an access gate, 3211 clear width opening, within 30 feet of turnstile. 2-3304(i.4) 17:')There shall be a clear area on each side U(f door, 6011 deep in direction of door wing and 4411 deep in opposite direction f door swing. 2-3304(i,l) · door .;>, L +z> she I v; ":j ) b. Doors (other than handicap-compartment) are not to encroach more than 1211 into above mentioned clear space. 2-511.l{a) . c. Provide a 2811 clear space between water closet and fixture or 3211 clear space between water closet and wall. 2-Sli.l(a) d. A 4811 long clear space is front of water closet. space is required when compartment has a s~de door •. 2-511.l(a) . required in A 6011 clear the toilet e. Water closet compartment door to provide 3211 clear widt:ll ·for end entry and 34:11 clear. width for side entry. Door to be self-closing. 2-511.l(a) 0SINGLE ACCOMMODATION TOILEI FACIL~TIES I';."\ Water closet shall be located 2811 from a \..:/ ,.fixture or 3211 from a wall. 2-511.l(a) ) ~ -thfs dr,e..:s~+ s C-A,\-e, a.+ ~,IP{ ..P./,,r rt?e?ft'\ -J; Minimum clear space in front of water / closet l?hall be 4811 • 2-511.l(a) Jfa. 1-In an existing building, a single accommodation toilet facility may have a space 3~11 wide x 48 11 long in front of water closet. 2-511.l(a) GRAB BARS AT. WATER CLOSE'! ( a. One at side 4211 long extending 2411 in front of water closet; one at rear 3611 long centered on -water closet; both mounted 3311 above floor. Where a tank- type toilet is used, grab bar may be as high as 3611 • 2-511.l(a) b. Bars shall be 1-1/411 . to 1-1/211 in diameter with 1-1/211 clearance to wall. 2-511.l{a) c. Bar fasteners-and mounting support shall be able to .withstand 250 lbs./ft. in· bending, shear and tension.· · 2-511.l{a) · . ·· 1,. WA+ER ci.OSE'! a. Height of water closet seat shall be 1711 to 1911 above floor. 5-1502 b. Controls shall be · operable with one hand, and shall not require tight grasping, . pinching or twisting of the wrist. 5-1502 c. Controls for the flush valves shall be mounted on the wide side of toilet areas, no more than 4411 above the floor. 5-l.502 d •. The force required to activate controls shall be no great-er than-5 pounds force. 5-1502 . .. .. .:: .. , .. t· URINALS a. Where urinals are provided, the rim of at least one shall project 1411 from the wall and be located 17 11 maximum above floor. 5.:1so3(a) b. The force required to activate the flush valve shall be 5 lbs. maximum and located 4411 maximum above floor. S-1503(b) c. Provide 3011 x 4811 forward.approach. LAVATORIES clear floor space for 2-511.l(b) a. Provide 3011 x 4811 clear floor space for forward approach. Said clear floor space may include knee and toe space under lavatory described below. 2-511.l{b) b. Provide clear space beneath lavatories 2911 high by 3011 wide by 811 deep at top and 911 high by 3011 wide by 1711 deep at bottom from front of lavatory (toe space). The maximum counter surface height should be 3411 • 5-1504(a) c. Hot water and drain pipes under lavatories shall be insulated. 5-1504(b) d. Faucet controls and operating mechanism (operable with one hand) shall be of the type not requiring tight grasping, pinching or twisting of the wrist (such as lever-operated) and an operating force not exceeding 5 lbs. 5-l504{c) e. If self-closing valves are used, they shall remain open for at least 10 seconds. 5-1504(c) I0ILEI ROOM ACCESSORIES a. Mirror bottom edge shall be located 4011 maximum above floor. 2-511.l{b) .· · b. Toilet tissue dispensers shall be mounted within 1211 from the front edge of toilet seat. 2-511.l{b) c. Operating parts of dispensing and disposal fixtures (towels, waste, coin slots, etc.) shall be within 4011 of floor. 2-511.l(b) f9. SANITARY FACILITIES IDENTIFICATION a. On doorways leading to sanitary facilities the symbols to be provided are 1211 Equilateral triangle for men, 1211 diameter circle for women, and 1/411 thick, centered on door, 6011 high and contrasting color. Unisex facilities shall be identified by the circle with the triangle superimposed within the circle. 2-Sll~l(a) . : Date ssf?v(qz__ Prepared bys k:'u+GA1H< Jurisdiction CARLSBAD VALUATION AND PLAN CHECK FEE PLAN CHECK NO I 9 I-9 '9-t, ·REtl) BUILDING ADDRESS I O~'S' L-=t.c.½:t'.)G<. Ot- o Bldg. Dept. D Esgil v APPLICANT/CONTACT ________ PHONE NO. . .Z,;s:t~ Y3 Ir, BUlLDING OCCUPANCY------------DESIGNER PHONE ------TYPE OF CONSTRUCTION__________ CONTRACTOR PHONE ____ _ BUILD'ING PORTION BUILDING AREA 'VALUATION VALUE MULTIPLIER 12.e.,U r--:$ t '-o·YJ < _.; E-sa /I /;,,_ -I '/;;z.. h 1!7 u.r .<:.. t. .:1:1, '%7. 1.5 /Jir. -$ '=:>0.-7 ~ J .. Air Conditionin~ Commercial ... @ ~ .. Residential (a ' .Res. or Comm. Fire· ~nrinklers @ .. Total Value Building Permit f"ee $ _______ -_________ ......,._ ______ _ Ci-hi Plan. Check f"ee_.....;S=----:...-.w:..£...L'--'-'l-=-..;;._-------------..;:;_--'-=-=:;;.,._-'-'----I /30273, ~-$ /t, 3, L/ I .. CO H HEN TS._:--------------------------------- SHEET __ OF_/ __ 12/87 :·· Git;~ -of Carlsbad . _ . · -_ · · . . Fire Department ·92116 • Bureau of Prevention Plan Review: Requirements Category: Building Plan Check Date of Report: Monday, June 1, 1992 Reviewed by: (? ,Oa__f J_,, Contact Name Address City, State Slllman/W:yman,_ Inc. 9609 Waple$ St Ste 200 San l;)iego CA 92121 Bldg. Dept. No . .....,,·s __ 1-___ s_a_a ___ _ Planning No. Job Name La_s Villas De Carlsb Job Address _1_o_aa..,..L ____ a __ g_un..,.._a __________ __,.. __ ---,----,--_ Ste. or Bldg. No. ____ _ ~ Approved ~ The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifica- tions, musf be reviewed by this office to insure continued conformance with applicable codes. Please review car~fully all comments attached, as failure_ to comply with instructions in this report can result in suspension of permit to construct or install improvements. D Disapproved -. Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. For Fire Department Use Only 2nd __ _ 3rd_~_ Other Agency ID CFDJob# --,----~ 92116 File# --~- 2560 Orion Way -• Carlsbad, California 92008 • (619) 931-2121 ,, . ! SILLMAN/ WYMAN & ASSOCIATES ARCHITECTS • ENGINEERS 10671 ROSELLE ST., SUITE 200 SAN DIEGO, CALIFORNIA 92121 (619) 4!53-4320 PROOOCT204-l /Neiis/ Inc.. Grolon, Mm. 01471. Joa k-A-5 Vtu,fts ~ ~L"S®A.:P I SHEET NO'. __________ OF-------- CALt;:ULATED av ________ DATE ______ _ CHECKED BY---------DATE------- SCALE. .. i ........... ; .. · .. ..l .......... ~ .. . . t ........ ~-. . ' : : . ·r····· . ~ ........ : .......... ~ ......... ) ... . . ' .. ; ........ ·.· .. .. .i.. .. . . ~ .......... :. . .. ·-·. . . .. , ....... ~ ? ........ ; ..... : .......................... +-· · 1 ...... ,;... . . -~-·-··. ···;·-·· ..... i ..... t·· ...... i ...... ·i········"t"· ...... .. . : ; : ., ................................................ . .... : ........... :. ... _ 1 __ ,., ..... : •••....•.•. ,,. ....•..• · ......... : ........... = ....................... _ ............................ : ...... , l ,. .. ~-..... .l....... .. .. ......... : .. ····· ........... :· .. . . . :, .......... _ ................... . -~---... ': ............... ····· ... J ........... . · ........ ; .................... . SILLMAN/ WYMAN & ASSOCIATES ARCHITECTS & ENGINEERS JOB----------------------- SHEET NO'. Z,_ OF---------10671 ROSELLE ST., SUITE 200 SAN DIEGO, CALIFORNIA 92121 CALCULATED BY ________ _ DATE _______ _ (619) 453-4320 CHECKED BY----------DATE-------- SCALE •.. __ • ..:, ........ -.. ........... . .•. . . . .... 1· l ....... L ..... : .......... , ....... \t~~ .. , .. e .... c~ ......... 1.9-'\ ......... ~ ........ ~ ....... L ....... : ........ ; ........• T ....... ~ .......... _. : ' . : .). ............................. . • ' I : : • _./ • ....... : ........ ..! .......... ; .......... ; .......... '. ... L/l-,. .... _. ........... 1s99~ .. : ...... ~ ... '.Zi~ !?..,; ,,,:n:; ir L-1. :-"" .. 4P .... .-< '3?.j"?... = . 64_9 .............. ,.. ...... , ....................................... CQ.G.. ..... ! .. tt..~:7¥ ;,< .... '-/z . . ..... ..... . ": .... 3..rJ$ ........................... 0 • ......... ... ... • • ............. \,-\1!-,l,.:.., ... , .. . . . Bv -~--~ ,_:_::_·"~~~ J t'~!r-_ . --.. ... . . %> I I. S . · · Ii. /\ '2:::: , °"' · , .... ...... .. . ........ .. .. K.\. "=E-•. 1,..1.<l ... 0,./?,::;/ t 8 .. l .. ·._7~1.,5J: .. ~ .. 8,.3 .... .......... .... .. , ....... , ........................................... f(.~ .~ ...... : ... ". ..... ~ ... :\" ·,, (~/.:11 J. "'.': ... lt .. S ~ .. -.-_ .... 1o .. \-1'1..:;..,-,,.:.. ' . . . . ; : . .... ....... ... . .. -~·"·. . .... . . ...... ~-·· . .. . . . . . ...... . ........................... : ............. ~. ?~f."(f'~IJ '1\ .......... ·:"· ............. , ............. \\.;\'·-.:::,; .... . . .... .. ... .. .. : ... .. ; : ~-(, : · uL-=\\4.0 . ...................... G·-·r ........................... .. ..... . ; ....... ' .......... i .... ! :'\' .: .. 1 ........ : .......... J-\ """:'.. \. \ .:\,o (q ·1.i~ ?: ..... \ \ '54:t. ........ i' ......... i... ... .. . '. .... : ......... -s. -:::.j1 .-54'7.,,, (1 ~') /1: o"=j := \ t.:)'3 .. ........ ...... ........ ........... .. ............................ J:.,~. :" .. 1 '."5 (! 1~1p) (.'J/7.. ~1);. 7_'5 =-Cc,?;; ....... ;. .................. · .. . .......... ·: ........... :....... ... ... ·-,"· .... , ..... : .. .. .................................. ........ . ' L.. \; G.x.1~ , ... C?.R. ............ ·"'! ..... , ....... . ,ZQ.\ u\ .. ? .1~q(1V~\+.1-z.?(Go/z.) +11:0 ~ ,410· t-1\ ~ .. \ 4'1 o (..e,,, Ys ") . ~ w.::? 1? . 'S . ~ GG I t;:0 ;-~.:) /l:, '?..) =-'SC\ ~~ ... ~. ,.~ (.1.4ri,o)(~--:\)/=r:15. ~. 4.<o ......... .' .................................................................... ~.Sl;: ', .. ~."/..3 '>< .Yi .... { 2~F) PROOOCT204-l/Niflfs/lnc.. Groton, Mm 01471. ........ ' SILLMAN/ WYMAN & ASSOCIATES ARCHITECTS • ENGINEERS 10671 ROSELLE ST., SUITE 200 SAN DIEGO, CALIFORNIA 92121 (619) 4!53-4320 ; !--i--!----'----< . ! : ---:---i-j ___ '_ :--l-; . :-· ..... !·_····_··_· '--- ············------,---...;--- ' : . : JOB------------------------- SHEET NO'.----------~~ OF---------- CALCULATED av _________ _ CHECKED BY----------- SCALE DATE----'------- DATE--------- .... ; .......... · ........ · ................... : ........... '. OoMn•t••••••••"'i 00••••••0 ........... ) .. · ............... : ... ············-···-· : . ; : . --~ ....................... : ........ · ............. : .. , ....... ;-.......... ! ............ : ....... , ............... . .... ! ..... . ..! ........... .. l---"---4········ .. :,,,' ..... _,___......_ ·' ..... ..! ....... ..!. ........... · ...........................•...... ! ............ ·. ······.• ' l ! ............ (. ····;···· ..... .' ..... ·-···/···· .... ;············' .................... .-....... -........... .,-: ........ ..; ......... / ........ ·'············,··· ... : .......... , .... , ........... · .... ; .......... , ....... · ........ ····· .......... i ................ ; ....... l ....................... , ....... . --/-i--/----f---~l<. 1.)--!-J~,if1/91~_1f1~-~ji~. -;-~d":l-~ :c~;_-~5:;. z:;;~~~=-=T= l , , i : i ....... i ...... .-1.: ............ .:,: ....... .J ........... i,i ............ i, ........ .! exi .... · ··:.':: .. ::i2~ ,i·:.'.,. 1 ;: .. :~.;.·::: ... :·.~,:·. / ... :6::.~:::, 1 :.~ · ~.: ... .::<::.-.-.-.-. .-·::::,,,:;::.~.i.:····:·.-.-.-..... :.:::·.:: .. :·· ......... · .......... ·;····"·"" ; ............. : .......... : ....... ., .. : ........... ; ....... ":··· ........ : ........... : ,-r,:-.~/."' J .. .. . ... 1 .... : ...... ··-r·--· .... ; .. , : . ; . ' 1----'---....................... ~· ---'--- ............ · .......... ] .......... : ............. ; ..... . • ..................... '. .................. 1 ....... : •••••••• • ...................... . ... ···~ ....... t ..... ·'; .......... ~ .. '.. ..... .... . .. . . .. i ........ ! ................ ·-; ........ . ........... : ........... ~ ........... ; ............. : ............ L ............... . ............ : ............ ; .......... __.: ........... '·········:··· .... , .. ·····+········ .. \ ............. ' .. ·······: .......... r ......... i ........... , 1 : ' : ;"· ... . . ·~ ............... ; ......... i ..... . ............. i. . .......... ~ ........... ., ............ : ... . . .. ·f ............. ; ............ : ......... ; ..... _,......... .... .1. . .. .... : .... . ..... i ......... ~ ...... . . . ; . . ..... ~ ............. ; . •.. . .. .. '. ........... ; .. • . ..... ; ..... ; ................. : ........ . . ............................................ , ..... . . . . ............ ······t·"·' ·:· . . ·············· ~ ..... r······ ... : ......... !...... .. ~· .......... . ... -. .. .i ...... ,. 0 ................ Ao••••"•••UU•• ' .... :.... ... . . ...... ; .......... ~. .... -~········-·· ·1· ...... ~ ... ·t ......... ; .......... : ...... ·;······· .. i ............. . .. ; ............. '.·-··-· ······( ....... ;-··--..... = ...... ·--:--..... , ........ ,i, ......... r .......... ~ ..... ; ........... ; ........ .t ........ . \ . i . ) . . . , i . . . , , 1 : ;......___;_.....;.. _______ ! ......... ~ ........... l ........... : ...... -.. 1.· ......................... i.',,.,······· ..... ! .............. ;, ........ .L ...... .:... ...... .!,,' ........... ~ ............. :.. , , : : i . : , , ; ..... . i ' l : i . ; : : ' ...-....... -~ ....... _.;..--,-___,i . ; : ' : . ; ! ........................... -: ............. , ......... .' ............. : ........... '...................... ! ' . , , , . , , I , , , . PROOOCT204-l/Ml'Bs/lnc., Grolon. M.,._ 0147L .. B U I L D I N G 09/03/92 13:11 Page 1 of 1 Job Address: 1088 LAGUNA DR Permit Type: PLAN CHECK REVISION Parcel No: 155-272-19-00 Valuation: O Construction Type: NEW P E R M I T Suite: Lot#: PCR No: PCR92056 Project No: A9101214 Development No: 9160 09/03/92 0001 01 C-PRMT 02 109-00 Occupancy Group: Reference#: 910986 Qt.:/! /Qf(p Status: ISSUED Applied: 08/18/92 Apr/Issue: 09/03/92 Validated By: CD 234-4316 Description: DELTA A CHANGES ONLY (CLOUDS) : CHANGE BATH, SOME DOORS, ETC 453 4320 I fJi.SP. ANAL AP:o~AL --------=-·~a CLEARANCE -------== CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 ' . ESGIL CORP.ORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO" CA 92123 ·(619) 560-14-68 DATE: . ~be,.c: I I IGtq~ LJ APPLICANT '8JURISCTICTIQN~ JURISDIC':['.I0N: Ca.rl:e,had, PLAN. CHECKER PLAN CHECK NQ: 9 ,_ :l Bee -RE;\J SET: 0FILE COPY QUPS ODESIGNER PROJECT ADPRESS: 1O,e,e, I AjK.00 D~ PROJECT NAME: V,'lla.5 d.:e:-;·. Ca.cl:sbd _ D D 0 0 The plans transmitted herewith have been corrected where necessary and substantially ·comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdic~ion 1 s buil~ing·codes when minor deficien- cies identified--,-----------------'-are resolved and checked by building department staff._ The plans transmitted he,rewith have significant deficiencies id.entified on the enclosed check list and should be corrected and resubmitt~d for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy Qf the check list is enclosed for the jurisdiction to return to the applicant contact person. O The applicant's copy of the check list has been sent to: ~ Esgil staff did not advise the. applicant contact person that plan check has been completed. O E'sgil staff did advise applicant that the plan check has been cprnpleted. Person contacted: ------------- Date contacted: Telephone# ------------------0 REMARKS: --------------------------- By:· .£u,1a1wr ESGlLCORP()RATION Enclosures: c,+y-ot rrr..9ved f /g,-yi.,:; 0GA OcM ... ' .. --'.:'.ff ~l1f} . -" , \~~,,, 't:f?'?\:! : t'':j\!?t:1t'.ff I'\l[Yi:'!-;;·->r:>t' 'i-· ., -·, .. • -.· ,,._ ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: &j11-5-f o2<, /~f~ ~~~~1!;P. JURISDICTI0 JURISDICTION: -=C=a=r~/~~=P~a=d:;..:._ ___________ _ PLAN CHECKER OFILE COPY QUPS ODESIGNER PLAN CHECK NO: 9/-_q 'ct, /<EV SET : .:Z::-- PROJECT ADDRESS: /08'5?;-4:fv..nor_ fr-, PROJECT NAME: V///4,.~ d~ Gr/:S b~ \ D D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the .jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdic~ion's building codes when minor deficien- cies identified _____________ ___,,..,,,_ __ are resolved and checked by building department staff.. Th·e plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted.· for a complete recheck. The check list transmitted herewitb is for your information. The plans are being held a.t Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. ~ The applicant's copy of the check li$t has been sent to: ;:J7'M i<.,n:t4-n 1~09 uJ--p 1e.s 5f:.:J#J"2CCJ ~ {);:JP r~; cl../ ~ Esgil staff did not advise the applicant contact person that plan check has been completed. O Esgil staff did advise applicant that the plan check has · -been completed. Person contacted: ---------------. Date contacted: ________ Telephone# _______ _ D REMARKS: -------------------------- By:· £tt;k; ESGIL CORPORATION ~/-w Enclosures: ---------- 0GA OcM --. . ,,. ~-.. ,~c0·'~•~;~~~~~~ti~j<;~ ·:,.:._'1_ ·:: JURiSDICTION: .• . C,a;,c/5/:,tU.( Date plans· received by plan checker: 'i?f}ZPl'la '\ PLAN ~~K NO.: ·rt: crs, gEy ·oate pl~ check completed: 3/'z.1/ 'fz_ By: /G.µ-+-wht«: PROJECT ADDRESS: /CJ~ [_'fJU/2'fl-oc.· IO.: . vim RP m-t-n · . PLAN CORRECTION SHEET FOREWORD: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled· access.-The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the ~lanning Department, Engineering Department or other departments. The items shown below need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the -cited codes and regulations. Per Sec. 303(c), of the Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. ~ Please make all corrections on the original tracings and submit two new sets of prints, and any orig.inal plan sets that may have been returned to you by the jurisdiction, to: Esat'/ . Q Io facilitate checking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this · check sheet with the revised.plans. l . . ai:: a 4P CCt (eU?r') Tete - 7, /)e,-k, I I /ft IQ ca /Is. .(;r e. Pr, st tl--k Mu-BR,ffl, ·'!J f t(Ml.'S • ~ Please indicate here if any changes have \..::.;,/ been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made to the plans not resulting from this correction list? Please check. ____ .Yes _____ No 7 tu/2,'d, o/, $t'bc€ d;;c 8 ls :t ~ fo/::'J ex, t: _be tftt cacct/!<19 1f-w~~1q1. ;;5"1:n -t/,cd: 5q-, 3.30f u) ,ortJ 61hr ts /1-(5ecr 3¾?9 1&5..s 3/fo/ ) ... Form No. PCS.41390 _., \~~;ff!~t-· /fft)tf¥]~;::.~{:t1:~~~~0\tr·(5l{~l~ .~: .. ~_r.~_:_F_;_!.!_,_:_ .. ~_:_\_;(;_;,:r'. :_'.· ..... _·._-. _ .. :_,: __ ..... ~ ~.-... ,,....:: .. :_.., __ :.~ -~f __ .:.,. __ f_tf_:i_:c(_\ .. ·-~;_,~{ __ .. :--_~J;_1_::_·~t_f_t_}_~~-:.f_i_li,:@i_;:~:_d,f +;Vi~~::tti"~f F}'t:r:r t"O;\t'=~::1r\ 1.:1~'.?'t./ > --. -. -_ '\ _ .·::~_<· o·i-~~,-g&.t,'k Jurisdiction G,.dd/,d - Prepared bys i<u,r-1-CJ&r VALUATION AND PLAN CHECK FEE PLAN CHECK NO. Cff-18"~ Rf=V o Bldg. Dept. 0 Esgil BUILDING ADDRESS IO'B"fs' L,lt,'ffY'l ~-{)r-. ---------=--;,j,-=,-.,___..-.. _______ __,. _____ _ APPLICANT/CONTACT JI '§:,m "t1'1 PHONE NO • __ '1_5_3-_4_~~0 __ BUILDING OCCUPANCY DESIGNER PHONE Ii 11 TYPE OF CONSTRUCTION ---------CONTRACTOR PHONE ----- BUILD!NG PORTION BUILDING AREA VALUATION VALUE MULTIPLIER . DIX', ~&!..v\.CI~ !: ·. ~it:( 1 • / v h, : I k,..1 r-r,; $ g7., IS/ k. := -:fl, ~7 ... /-~ v ' ', -- .. - Air Co.ndi tionine: Commercial @ .. Residential '. @ Res. or Comm. Fire S"Drinklers @ Total Value Building Permit fee$ __________________ _..... ______ _ Ct'ty Plan C h.e ck f ee_$ __ ~_. ___ , __ s .... / ...... , ~-------------------$'---'/-=0-~aa..-' ~ __ ..,.__ __ _ COM ME: N TS . ._:--...----,.------...------------------ SHEET _L OF_,_ __ 12/87 , . ·=: \ PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB 9l -099{~ ADDRESS fdA~ L~t IN.4 DR. RESIDENTIAL RESIDENTIAL ADDITION MINOR ( < $10,000.00) DATE 2./a AUb C)2._ TENANT IMPROVEMENT . PLAZA CAMINO REAL VILLAGE FAIRE COMPLETE OFFICE BUILDING PLANNER-----------'----DATE _______ _ ENGINEER So£C.f~Ef)E_LL DATE 21a AUG '12- '- C:\WP51\FILES\BLDG.FRM Rev 11 /15/90 ' 1 I I ,,' i j i ' -.~ ' t .1 ., ., "~ I ~ ' ·N ! ....} J ~ QI ., .., .., CII CII Q Q ~, I ]' ]' ... N --~ ~ <J <J QI QI .s: .s: u u C: C: CII co --Q, Q, QI .., CII Q ,, ]' ~ ~ <J QI .s: . u i .... Q, PLANNING OiECKIJST . , , . Plan Check No., CBCf/..-reG Address /009 ?4 0 CINA 'bVc. Planner VAN LYNCH Phone ,438-1161 ext. 4325 -------(Name) APN: / r-S---2--72-/9 Type of Project and Use ~l'bt:Jt.J71A/..-,. CAffe.-(:r' B(;./v~ . Zone . Facilities Management Zone __ / ___ _ Legend Item Complete Item Incomplete -Needs your action 1, 2, 3 Number in circle indicates plancheck number where deficiency was identified . ~0 Environmental Review Required: .YES_ NO ~TYPE __ _ DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditi<;>ns which require action. Conditions of Approval _______________________ _ ~0 Discretioruuy Action Required: YES ___ . NO~ TYPE __ _ APPROV AL/RESO. NO. ____ _ DATE: _____ _ PROJECT NO ........ ______ .,... ·, '! OTHER RELATED CASES: : ------------------------- Compliance wi.th conditions of approval? If not, state conditions which require action. Conditions of Approval __ · ______________________ _ California Coastal Commission Permit Required: YES _ NOP\ DATE OF APPROVAL: ., -.... .. •• l. • ~ , \ l San Diego Coast District~ 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725 . (619) 521-8036 . Compliance with conditions of approval?· If not, state conditions which require action. Con4itions of Approval-------------------------- ~ 0 Landscape Plan Required: YES __ NO~ . : , .... · . ', . ..,.~' -... '·. ~ ' ', See attached submittal requirements for landscape plans Site Plan: ~D AJf lB'1J D )I(~ efao11/v 1. 2. 3. 4. 1. 2. 3. 4. Provide a fully dimensioned site plan drawn to scale. Show: North a_rrow, property lines, easements, existing and proposed structures, · · streets, existing street -improvements, right-of-way width and dimensioned setbacks. Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and driveway. Provide legal description of property. Provide assessor's parcel number. Setbacks: Front: Int. Side: Street Side: Rear: Lot coverage: Height: Parking:. Required Required Required Required Required Required Spaces Required Guest Spaces Required ___ Shown __ _ Shown ------___ Shown __ ___ Shown __ Shown ------ ___ Shown __ ___ Shown __ ___ Shown __ D D D Additional Comments ______________________ _ OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER _v_-_ .. ··..,._Lf_,_~_-__ DATE 6-u-----r l PLNCK.FRM City of Carlsbad · 92116 Fire Department • · · Bureau of Preventio·n Plan Revi'ew: Requirements Category: Building Plan Check Date of Report: Thursday, August 27, 1992 Reviewed by_:' C ., J3 q...-( c.J,.___ Contact Name Address City, State SIiiman/Wyman, Inc. 9609 Waples St Ste 200 San Diego CA 92121 ( Bldg.-be"pLNo. _9_1-_9_8_6 ______ _ · Planning No. Job Name Las Villas De Carlsb Job Address _1_0..;...aa_L_a.,,.,gu_n_a ____________ _ Ste. or Bldg. No. ____ _ 181 Approved -The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided.in your submittal; therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to in~ure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. D Disapproved -Please see the attached report of deficiencies. Please make corrections to · plans or specifications necessary to indicate compliance with applicable c0des and standards. Submit corrected plans and/or specifications to this office for review. For Fire Department Use Only Review 1st,___ __ 2nd,___-,-_ 3rd. __ _ Other Agency ID CFO Job# 92116 File# ___ ~ 2560 · Orion Way • Carlsbad, California 92008 • (619) 931-2121 .,. SILLMAN/ WYMAN & ASSOCIATES ARCHITECTS & ENGi,fEERS • 10671 ROSELLE ST .. SUITE 200 SAN DIEGO, CALIFORNIA 92121 (619) 453-4320 I ~ L' i, JOB--\...,.1-'1\-=L-=Ct:,,,~~~-O~s:::: __ y--''-'-fZ-'-l.=S=->-t:2. ..... ,A~P=-_-_13='""'-l.-p-=---'7=-.-....cc.=- SHEETNO'.---------'-I_ OF-------- CALCULATED BY---------DATE ______ _ CHECKEDBY---------DATE------- SCALE i • i 1 ; l 1 ! l . ' 1 , : : ; , i i ; : : : ····.··········-·· i : .. {"'"' ......... ; ............. : ········ ~ .......... .! .......... : ..................................... . ':'""' • ......... ' ............. • • : : < .... T ........... "'···:·· ................... ; .. ~,-··<· ......... 1 .. , .. : ........... · ..... ; ................. . . ·--~·-· . . i ........ : . .. .-... .. . ·: .. ··· ·; . 'j'· ...... ' ; 1 : : l ! ···-· .... ~ ..... ··-· '. .......... {····· .... i.. ....... '. .. . .. '(· " .. + ...... '. .. "" ... . . ..... ....... ]"' ........ ' ....... 'l"'"".""l" " " '........... ..... . . : ......... . . . .................. " ....... , " ..... ........ .. .... . . ............. . . . . . .............. ,. ......... .. ' . ] ........ ;-······ ........ :, ...... . ~ .. ······· ............ r ........ : ....... :·--·-- = r-r:-t--li-: ~F~~ f :·_ ;zr c~if-2 t-j-fyli • , --, · · :~ -¾"_~;,-,J1-;x_ \' -·3--~ --· · i : ; : • ; ! = ~ ...... ·r. ... .. . ... ;.~ ............ :.i, ............ ; ...... ·--~.-· ........ :.. . . . :.,.:· .......... =· ....... r.... ... ; ····-··· . . .. .. . . . .. --·· ...... ---.-······ .... :-----------.. . .. ... : -------- j ; ! ; : PROOOCT 2114-1 /Nees/ Inc., G-. Mas,. 01471. .. SILLMAN /WYMAN & ASSOCIATES ARCHITECTS & ENGi,,IEERS • 10671 ROSELLE ST., SUITE 200 SAN DIEGO, CALIFORNIA 92121 (619) 453-4320 JOB------------------- SHEET N0: _________ 2,_ OF------- CALCULATED sy ________ DATE ______ _ CHECKED sy _________ DATE------- SCALE ········ ... ; ....... · .................... :.......... ·r····· ........ . ' ............. ---i •..•.• •v .. ••·•"" •••, • .,,,,.,, •• .,, • l • :• •·••••·••: """' •••••••••• . . ......... : ...... ;. ........ : ...... ··········!·······1··········; ····(. . ....... ·······;········:········ =:~~ /:: .. ~:;Fr ff f '~!~~r~:~.1;f: ;:-r-J :.· , -· ··· -:· ~: ··· ••······~······ ··•··· _:-.-= ·.·: , :rz , :G. ; · 1 s:,rrrc:: ""~ 1 ' ,,z_ c:=.,; 1 :><-· e::. , t.. -,., · , =-, 1 <5 o. , PROOUCT204-I /Nifl!is/lnc., Groton; Mass. 01471 SILLMAN/ WYMAN & ASSOCIATES ARCHITECTS & ENGl,NEERS JQB ___ \_,,_/..,_11....=l:::.ek..,,-:::.:::...._....:,:CE::::=-__cc=e:...:.«=l.S~lp!r.:,,:t:.A;C:;!i!,.,L _____ _ ,. 10671 ROSElLE ST., SUITE 200 SAN DIEGO, CALIFORNIA 92121 (619) 453-4320 SHEET N0: _________ __.:,"3"'---QF _________ _ CALCULATED sy _________ _ DATE ________ _ CHECKEDBY----------- SCALE DATE--------- .... ! .......... : . .. .................. ...... . i ............ , ....... :. .... . ... . . ... ; ..... : ... ...... .. . .. ; ...... ··!··· ... .. .......... · ........... -~-- ! ; ' . ....... ! . .( ~.;;,.t.): ....... '. ·······;·········· ! . · .......... ; ........ : ........... · ......... ':' ...... : ........ ; ... :····-.. ··:····· .... : .. ··· ............... . ................. , ........ . , ! ; : '-: 14 '~ ts~~ ... j-~fs:r..f ...... 41-.. 11 .• ~ ! .......... .;(~?T .... ;z.~ ... 9cJ .. .' ............................ ,. i . i l t ~ : ; ~ ; : i : i ................ : ............. :.. .......... ...........i ,..... . ~ ....................... .;. ........ ... . ...................... : .......... ·... . . . ... . . ..... ~ .......... . ...... .... . .. . . : .... . . . .............. ;... .. . . . . . ....... :... . ...: .............. . I- _, _· ! ! 8o(;D<;bu)~~: I : l l ; ; ; : I . ; ....... , ... . ~ ••• • : 1 : '. 1 ~ : ; ' ; • ! f ' · " ' · · " ... " .......... "" · · ..... :· , ... ········ · · ;. . ... "''!.· _) __ j / ___ Ll. rn'-4L.; __ [__ :~_'-!_'/,~ 2 __ ,. 1g \ 4 : }~-•------;;,~_ ...... (······ .. ; ... ) ........... t ! ! ; : : ..... ~~--·· .... ! ...... g';},.,{~t'~tt} .. t .. ~19.iJ.: ./2: ~ ... '.9 -z.bq_'. ' ; : ' . ! : .... :.-..... \ ..... ; ....... :.... : _\'.(oJC,CO·:.:, ~ ..... = 41.?9. ..... . .... ·.·········r ....... ·-1-+oc::,, P... ~"~····'4u:s· ... cb ~ii~·,- .................... : ............ ; -:-:: ....... §;3.=;i;iQ: .. . i I i , . , : ..... ··: .-.. . , ......... = ..... ·····;··· .. ·····I···· ·t······ '·········--[----· ...... : : ; . : ._. .......... , ·········;-···· . .t .. ......... _............ j . : l / • . 1 · I = ! I ~ .......... · ..... ··,·············1 .... , ....... ·+···········;··. ·····!········ .. :·········:············!·. ···--;·· ·······:········ .L ....... ; ... ···i·· ...... j .... , ...... ········ ..... , ........ ·r ..... . . ;...'--'--:··········I... ...... '.:·········--' ...... : ....... : .............. ,.'··· ... ...!. ............ ',.··········'············,.·· ; ; ; ,i ; : • I : l : i I ..... : ............. ; ................. : ............ { ....... : ................ : ...... : ....... : ....... :. ... : .......... :·· .... , ...... : .. ..... ! ....... --: ..... \-:?-.I.:? o ..... . .. ' 41.4.q:) .. ~.'1 ... :".: ... ~.99. .. ··;····· ~ \tP. .. c., . ' ..................... : ......... ; ...... I ........ i ....... : .................... ; ........... : ... . ! . : : . : ... ······ -~ ....... r ........ ~ ......... r .......... ~· ......... : ·····-·· :· ., .. :·· ... ..: ......... ,. . ....... .. ' ; ' ~ : . i : ; : . ' '. ........... , .... ···;······· ......... ·;· ...... , ....... ······ • 1 ··········· :·············i .. ·'·· ........ i .......... ··i· .... ·····,············I···········--j--······ .. :···· .... ··;··········· ...................... r ........ i ........ i ····· .... ;. ........... ;. .... ···-.................. , ........................................... ···-. . ........ . . . ............... . (--·····,············r········;··········t· ········;·· ............... L·······:·· ····'.··········\·················-<··· ·· ...... , ......... : ..... : ....... ;······.·····:·········· .. . : ~ : : ! . : : : : , : ··:· ·······'····· ······;·· . ·:.r·· .... i··· . ....... . .. ........ ............. = .............. ,......... • .. .. •. ...... •.• • .............. .; .. . . : . : ~ ~ . '. . . ! . N ........ : ............. i ....... : ......... t ........ ~ ............ : .......... ~ ........... L .......... ; .......... i ......... ·! .......... ·r· ... ·······= ..... :······ ..... i .. ···· ..... ; ........ ·:·· .. ·-··-r ... .,. . .... ... . ... ····i . ; ; '·····+·········j·········; ........ .;..., ......... , .......... , ...... ) ....... --r······--i-······+·········/··········L. ..................... ·····:··············· . ; l i ; : l ...... • --'----,.. ......... ~ ....... t··· .: ........ . ... : ......... ; ............ . I = j : : : : : .. . i · E ; ; : : ~ ,. : • • • ; • ........ .. • ............... ... • • •• • • • • .. • • i ; ~ ~ . i : ; ; l : . ............ ........ .... ·;-. --;,----,.-.. t·... .. i t"···· ............. ···i .......... ; .... . !··· .. . .. f ............ f.. ....•... . ......... i ..................... : ... . ..~ .......... " ......... . .. ...... r·· ...... ....... .. · .......... : ............. : ........... :··· ............ . . . ·: ......... ~ ....... I .......... : . . .. .... ~ ........ j ~-·· .•. ·! . .. .. ·! ......... . . ............. ; ......... ; ... , ..... ,, ......... : ......... !""" .. . PROOUCT204-I //Veiis/lnc., Groton, Mass. 01-471 B U I L D I N G P E R M I T PCR No: PCR92067 Project No: A9101214 Development No: 10/08-/92 10:50 Page 1 of 1 Job Address: 1088 LAGUNA DR Permit Type: PLAN CHECK REVISION Parcel No: 155~272-19-00 Valuation: O Construction Type: NEW Occupancy Group: Reference Description: MOVE DOOR #6 TO NEW LOCATION Suite: Lot#: 619 Status: ISSUED Applied: 10/01/92 Apr/Issue: 10/08/92 Valj,_<lated By;: , CQ 2 3 4_9j4,61 JO/uB/92 0001 01 v2 ~• C-PRMT 54 n 00 ~ • •~J , ' I ,-•lo FINAL APPROVAL INSP. __ DATE--• CLEARANCE-----• J,l . !' ..... ~ •.•. CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 City of Carls.bad 92116 · ·. Fire Department • Bureau of Prevention Plan Review: Requirements Category: BUIiding Plan Check Date of Report: Monday, October 5, 1992 Contact Name Address City, State SIiiman/Wyman, Inc. 9609 Waple~ St Ste 200 San Diego CA 92121 Bldg. Dept. No. _91_"'. ___ 9_8_6 ___ _ Planning No. Job Name Las Villas De Car1sb Reviewed by: C, l!JM~ Job Address _1_0 __ 88;_. L_a_g_un __ a;__ __ -__________ _ Ste. or Bldg. No. ____ _ ~ Approved -The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifica- . tions, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspensio,:i of permit to construct or install improvements. · D Disapproved -Please see the attached report of deficiencies. Please make corrections to _plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. For Fire Department Use Only Review 1st,__ __ 2nd,__ __ 3rd ·--- CFO Job# 92116 File# ___ _ . Other Agency ID 2560 Orlon Way • Carlsbad, California 92008 • (619) 931-2121 "' -J. ~ . ) ,· ESGIL CORPO-RATION . -dtrio CHESAPEAKE DR., SUITE 208 , . ·. SAN DIEGO, CA 92123 (619) 560-14-68 . DATE: 0<=<+-o bex-(p I I :l :l ~ c:§APPLICANT ~~~sg~~~ JURISDICTION: C C<,r (:sbcu;;{_ PLAN CHECK NO: SET: r QFILE COPY QUPS QDESIGNER PROJECT ADDRESS: lot2:e .LB':Jl.,(..Ylg_. Oc PROJECT NAME: C '"' II C<.'5 ol.<-c~rl-sbq.p( D D 0 D The plans transmitted herewith have been corrected where necessary and substantially comply with the .jurisdiction's building codes. The plans transmitted herewith ~ill substantially comply with the jurisdic~ion's building codes when minor deficien-cies identified _____________ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewitb is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of. the check list is enclosed for the jurisdiction to return to the a·pplic-ant contact person. O The applicant's copy of the check list has been sent to: E Esgil staff did not advise the applicant contact person that plan check has been compl,eted. O Esgil staff did advise applicant that the plan check has been completed. Person contacted: ------------ Date contacted: ---------Telephone# _______ _ 0 REMARKS: ------a------.,.,..--------------- By: .Kid livkec ESGIL CORPORATION 1015- OGA OcM ' ' . ' ~ . Enciosures: C:, h-*"'Mwvu/ t214ttS ......::~--r-r=.,-11~-::.!=_,,c,::..s.:.:.u..---- .. Date 1 10/1,{11c Prepared bys tdtvfvu: ' · Jurisdiction Cacfr,he-el VALUATION AND PLAN CHECK FEE PLAN CHECK N-0, '7 l-1-a'& gv' o Bldg. Dept. D Esgil BUILDING ADDRESS /0 8'f: 1-.:vru.nt:L Dr, APPLICANT/CONTACT J., 'f?ot"YlariJ PHONE NO. _______ _ B.UILDING OCCUPANCY ----,.-----DESJGNtR PHONE ------TYPE OF CONSTRUCTION -----------CONTRACTOR PHONE ----- BUILDING PORTION ·.BUILDING AREA VALUATION VALUE MULTIPLIER • J1/J ,/) I 14' _ ~iJ' r C, : ;:;:-~ i' I .{;,,:, ::--1/ .;z_ hou.r /i:J ~ ~7-15/ hr.= 'ff L/ 3 . z:; '8:' v -·· - . I . Ai~ Conditionine: Commercial' . -·-' @ Resid."entia:J: : . ' (a .. Res. or Comm. . .. .. Fire Snrinklers .. @ I Total Value Building Perm it fee $-----------------------"'-------- plan Che ck f ee--..:S:---'-'J/ 3,r!.;;•;....5u,:8':-,;/4~~...:;;::-. _____________ --"$---=5:;;..'i .... ,__,_'i~7---- CO H HEN TS._:-------------------------------- SHEET I OF ---.a.----