Loading...
HomeMy WebLinkAbout111 SEQUOIA AVE; D; CBRA2020-0129; PermitBuilding Permit Finaled Ccityof Carlsbad Residential Associated Permit Print Date: 08/07/2020 Job Address: 111 SEQUOIA AVE, # D, CARLSBAD, CA 92008-4029 Permit Type: BLDG-Associated Permit Residential Work Class: Repair Parcel#: Valuation: Occupancy Group: #of Dwelling Units: 2060132004 Track #: $2,166.00 Lot#: Project#: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: PC2020-0012 Plan Check#: Project Title: Description: FULL CIRCLE MANAGEMENT: REPAIR UNIT D DECK FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Property Owner: FULL CIRCLE MANAGEMENT 4123 AVENIDA DE LA PLATA OCEANSIDE, CA 92056 581473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $91.38 Total Payments To Date: Building Division $91.38 Permit No: CBRA2020-0129 Status: Applied: Issued: Finaled Close Out: Inspector: Final Inspection: Balance Due: Closed -Fina led 03/16/2020 03/31/2020 CRenf 08/07/2020 AMOUNT $52.87 $37.01 $1.00 $0.50 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov Building Permit Inspection History Finaled {city of Carlsbad PERMIT INSPECTION HISTORY for (CBRA2020-0129) Permit Type: BLDG-Associated Permit Residentil Work Class: Repair Application Date: 0311612020 Owner: FULL CIRCLE MANAGEMENT Issue Date: 0313112020 Subdivision: CARLSBAD TCT#84-18 Status: Scheduled Date 05106/2020 08/07/2020 Closed -Finaled Expiration Date: 03131/2021 25415 Address: 111 SEQUOIA AVE, # D CARLSBAD, CA 92008-4029 IVR Number: Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Status BLDG-14 126521-2020 Failed Chris Renfro Frame/SteellBoltlngfWe ldlng (Decks) Checklist Item BLDG-Building Deficiency COMMENTS Proposed deck guardrail repairs does not meet minimum code of 42 inches. Double check plans for three and seven eights inches gap between baluster and bottom rail and deck. Does not meet heights and clearances per the plans. Call for reinspection for all decks. BLDG-Final Inspection 126522-2020 Failed Chris Renfro Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLOG-Mechanical Final BLDG-Structural Final BLOG-Electrical Final COMMENTS Proposed deck guardrail repairs does not meet minimum code of 42 inches. Double check plans for three and seven eights inches gap between baluster and bottom rail and deck. Does not meet heights and clearances per the plans. Call for reinspection for all decks. BLDG-14 135008-2020 Scheduled Chris Renfro Frame/Steel/BoltlngfWe ldlng (Decks) Checklist Item BLDG-Building Deficiency COMMENTS Proposed deck guardrail repairs does not meet minimum code of 42 inches. Double check plans for three and seven eights inches gap between baluster and bottom rail and deck. Does not meet heights and clearances per the plans. Call for reinspection for all decks. BLDG-Final Inspection 135009-2020 Passed Chris Renfro Reinspeclion Inspection Relnspectlon Incomplete Passed No Relnspectlon Incomplete Passed No No No No No Passed No Incomplete Complete Friday, August 7,-2020 Page 1 of 2 Permit Type: Work Class: Status: Scheduled Date PERMIT INSPECTION HISTORY for (CBRA2020-0129) BLDG-Associated Permit Residenlii Application Date: 03/16/2020 Owner: FULL CIRCLE MANAGEMENT Repair Issue Date: 03/31/2020 Subdivision: CARLSBAD TCT#84-18 Closed -Finaled Expiration Date: 03/31/2021 Address: 111 SEQUOIA AVE, # D IVR Number: 25415 CARLSBAD, CA 92008-4029 Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspectlon Inspection Start Date Checklist Item BLOG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLOG-Electrical Final Status COMMENTS All corrections from previous inspection have been complete. All decks units D, E, and F on west side decks only. Passed Yes No No Yes No Friday, August 7, 2020 Page 2 of 2