Loading...
HomeMy WebLinkAbout111 SEQUOIA AVE; F; CBRA2020-0132; PermitBuilding Permit Finaled '.,,-----·-~------------- Ccityof Carlsbad Residential Associated Permit Print Date: 08/07/2020 Job Address: PermitType: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: 111 SEQUOIA AVE, # F, CARLSBAD, CA 92008-4030 BLDG-Associated Permit Residential Work Class: 2060132004 $2,166.00 Track#: Lot#: Project#: Plan#: Repair Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: PC2020-0012 Plan Check#: Project Title: Description: FULL CIRCLE MANAGEMENT: REPAIR UNIT F DECK FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Property Owner: FULL CIRCLE MANAGEMENT 4123 AVENI DA DE LA PLATA OCEANSIDE, CA 92056 SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $91.38 Total Payments To Date: Building Division $91.38 Permit No: CBRA2020-0132 Status: Applied: Issued: Fina led Close Out: Inspector: Final Inspection: Balance Due: Closed -Fina led 03/16/2020 03/31/2020 CRenf 08/07/2020 AMOUNT $52.87 $37.01 $1.00 $0.50 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov Building Permit Inspection History Finaled (cityof Carlsbad PERMIT INSPECTION HISTORY for (CBRA2020-0132) Permit Type: BLDG-Associated Permit Residenti, Work Class: Repair Application Date: 03/16/2020 Owner: FULL CIRCLE MANAGEMENT Issue Date: 03/31/2020 Subdivision: CARLSBAD TCT#84-18 Status: Scheduled Date 05/06/2020 08/07/2020 Closed -Finaled Expiration Date: 03/31/2021 IVR Number: 25418 Address: 111 SEQUOIA AVE, # F CARLSBAD, CA 92008-4030 Actual Inspection Type Start Date 05/06/2020 BLDG-14 Frame/Steel/Bolting/We ldlng (Decks) Checklist Item Inspection No. 126520-2020 COMMENTS Inspection Primary Inspector Status Failed Chris Renfro BLDG-Building Deficiency Proposed deck guardrail repairs does not meet minimum code of 42 inches. Double check plans for three and seven eights inches gap between baluster and bottom rail and deck. Does not meet heights and clearances per the plans. Call for reinspection for all decks. BLDG-Final Inspection 126519-2020 Failed Chris Renfro Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS Proposed deck guardrail repairs does not meet minimum code of 42 inches. Double check plans for three and seven eights Inches gap between baluster and bottom rail and deck. Does not meet heights and clearances per the plans. Call for reinspection for all decks. BLDG-14 Frame/Steel/Boltlng/We ldlng (Decks) 135013-2020 Scheduled Chris Renfro Checklist Item BLDG-Building Deficiency COMMENTS Proposed deck guardrail repairs does not meet minimum code of 42 inches. Double check plans for three and seven eights inches gap between baluster and bottom rail and deck. Does not meet heights and clearances per the plans. Call for reinspection for all decks. BLDG-Final Inspection 135012-2020 Passed Chris Renfro Reinspection Inspection Relnspectlon Incomplete Passed No Relnspectlon Incomplete Passed No No No No No Passed No Incomplete Complete Friday, August 7, 2020 Page 1 of 2 Permit Type: Work Class: Status: Scheduled Date PERMIT INS.PECTION HISTORY for (CBRA2020-0132) BLDG-Associated Permit Residenti, Application Date: 03/16/2020 Owner: FULL CIRCLE MANAGEMENT Repair Issue Date: 03/31/2020 Subdivision: CARLSBAD TCT#84-18 Closed -Finaled Expiration Date: 03/31/2021 Address: 111 SEQUOIA AVE, # F Actual Start Date IVR Number: 25418 CARLSBAD, CA 92008-4030 Inspection Type Inspection No. Inspection Primary Inspector Reinspectlon Inspection Checklist Item BLDG-Building Deficiency Status COMMENTS All corrections from previous inspection have been complete. All decks units D, E, and Fon west side decks only. Passed Yes BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final Yes BLDG-Electrical Final No Friday, August 7, 2020 Page 2 of 2