Loading...
HomeMy WebLinkAbout1110 CHINQUAPIN AVE; ; CB043917; Permit12-07-2004 Job Address Permit Type Parcel No Valuation Occupancy Group # Dwelling Units Bedrooms Project Title City of Carlsbad 1635 Faraday Av Carlsbad CA 92008 Residential Permit Permit No CB043917 Building Inspection Request Line (760) 602-2725 1110 CHINQUAPIN AV CBAD RESDNTL Sub Type 2062612200 Lot# $41 580 00 Construction Type Reference # 0 Structure Type 0 Bathrooms ANGEL RES 378 SF GAME ROOM ADD RAD 0 NEW Status Applied Entered By Plan Approved Issued Inspect Area Ong PC# Plan Check* ISSUED 10/18/2004 SB 12/07/2004 12/07/2004 Applicant CHALLENGER CONSTRUCTION 4310 LA PORTALADA DRIVE _ 92008 Owner ANGEL JOE&JUANITA 1110 CHINQUAPIN AVE CARLSBAD CA 92008 760 672 2700 Building Permit Add I Building Permit Fee Plan Check Add I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add I Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add I Pot Water Con Fee Reel Water Con Fee $30971 Meter Size $0 00 Add I Reel Water Con Fee $201 31 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $416 PFF $0 00 PFF (CFD Fund) $0 00 License Tax $0 00 License Tax (CFD Fund) $0 00 Traffic Impact Fee $0 00 Traffic Impact (CFD Fund) $0 00 Sidewalk Fee $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Housing Impact Fee $0 00 Housing InLieu Fee Housing Credit Fee $0 00 Master Drainage Fee $0 00 Sewer Fee Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $2000 $2400 $000 $000 $000 $000 $000 $000 $55918 Total Fees $55918 Total Payments To Date $201 31 Balance Due $357 87 LDING PLAlN^ IN STORAGE ATTACHED 7029 12/07/0* 0002 01 CGF 02 Inspector FINAL APPROVAL Date <J // WftS Clearance NOTICE Please take NpTICphat approval of your project includes the Imposition offees dedications reservations or other exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connecton with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired 87 APPLICATION ^ CITY~OF CAFItSBA^MlLDlM'DEPART 1635 Faraday Ave Carlsbad CA 92008 1 PROJECT INFORMATION h/ft FOR OFFICE USE ONLY PLAN CHECK NO EST VAL Plan Ck Deposit Validated By. _ es-Jll Address (include Bldg/Suitl #)Business Name (at this address) Legal Description Lot No SubdivisioOxName/Number Unit No Phase No Total # of units Assessor s Parcel #Existing Use Proposed Use Description of Work ? SQ FT #of Stories # of Bedrooms # of Bathrooms APPOCA eontractor Address Agent for Contractor* Q Owner State/Zip/*^ Telephone #Fax # Name 3b£ -f 4 PROPERTY OWNERs Address (I/O Cltv State/Zip ^* "<% Telephone # Address City State/Zip Telephone #Name 5 CONTRACTOR COMPANYi NAME \ m1 '•> '"" ^ ** (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom and the basis for the alleged exemption , Anv violation of Section 7031 5 by any applicant fo/ a permit subjects thus applicant to a civil penalty of not more than five hundred dollars [$500]) Name State License # ft U& /^ ^ ^ Address License Class City State/Zfp Telephone # City Business License # /£-/ if e? ^/ Designer Name «g A~A~ Address City State/Zip Telephone State License # 6 •"""WORKERS COMPENSATION "^^ "p™ *"" " ~~~" *«** '"" %>*.., Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations O I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued n I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My worker s compensation insurance carrier and policy number are Insurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) 4J3 CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100.000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE iJfWtM C\ ^LJff^&ylS*^ DATE 7f OWNER BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor s License Law for the following reason l~l I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) l~l I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) l~l I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement l~| YES flNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR NOfTRESIDENTIAL BUILDING PERMITJfONLY *fc ** Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? O YES Q" NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' l~l YES l~l NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site' f~| YES l~l NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 8 JgpfSTRUCTION LENflTG AGENCY ** ^ IS. W (^'^ I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER S NAME LENDER S ADDRESS 9 fAPPUCAI?rlSjTIFlCATlo¥"~ ^* i ' ^ ™ I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commence^fOjiya pe/iod of 180 days (Section 106 4 4 Uniform Building Code) APPLICANT S SIGNATURE DATE WHITE File YELLOW Applicant PINK Finance City of Carlsbad Bldg Inspection Request For 04/14/2005 Permit* CB043917 Title ANGEL RES 378 SF GAME ROOM ADD Description Type RESDNTL Sub Type RAD Job Address 1110 CHINQUAPIN AV Suite Lot 0 Location OWNER ANGEL JOE&JUANITA Owner ANGEL JOE&JUANITA Remarks Total Time Inspector Assignment PY Phone Inspector CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By NA Entered By CW Act Comment Associated PCRs/CVs Inspection History Date 03/28/2005 03/02/2005 02/07/2005 02/01/2005 02/01/2005 01/31/2005 01/28/2005 01/28/2005 01/28/2005 01/18/2005 01/18/2005 12/22/2004 12/21/2004 12/21/2004 Description 89 18 17 14 34 34 14 34 39 13 15 11 11 12 Final Combo Exterior Lath/Drywall Interior Lath/Drywall Frame/Steel/Bolting/Weldmg Rough Electric Rough Electric Frame/Steel/Bolting/Weldmg Rough Electric Final Electrical Shear Panels/HDs Roof/Reroof Ftg/Foundation/Piers Ftg/Foundation/Piers Steel/Bond Beam Act CO AP NR AP AP PA CO we we AP AP NS AP we Insp PY PY PY PY PY PY PY PY PY PD PD PY PY PY Comments NO ONE THERE OK TO INSULATE SEE LIST ALREADY DONE City of Carlsbad Bldg Inspection Request For 03/28/2005 Permit* CB043917 Title ANGEL RES 378 SF GAME ROOM ADD Description Inspector Assignment PY 1110 CHINQUAPIN AV Lot 0 Type RESDNTL Sub Type RAD Job Address Suite Location OWNER ANGEL JOE&JUANITA Owner ANGEL JOE&JUANITA Remarks Total Time Phone Inspector Requested By NA Entered By CHRISTINE CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comment Associated PCRs/CVs Date 03/02/2005 02/07/2005 02/01/2005 02/01/2005 01/31/2005 01/28/2005 01/28/2005 01/28/2005 01/18/2005 01/18/2005 12/22/2004 12/21/2004 12/21/2004 Inspection History Description 18 17 14 34 34 14 34 39 13 15 11 11 12 Exterior Lath/Drywall Interior Lath/Drywall Frame/Steel/Bolting/Weldmg Rough Electric Rough Electric Frame/Steel/Bolting/Welding Rough Electric Final Electrical Shear Panels/HDs Roof/Reroof Ftg/Foundation/Piers Ftg/Foundation/Piers Steel/Bond Beam Act AP NR AP AP PA CO we we AP AP NS AP we Insp PY PY PY PY PY PY PY PY PD PD PY PY PY Comments NO ONE THERE OK TO INSULATE SEE LIST ALREADY DONE CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE (760) 602 2700 1635 FARADAY AVENUE f FOR INS'B6CTION CALL (760) 602 2725 RE INSPECTION FEE DUE? FOR EtfRTMER INFpRraATlQN CONTACT YES .( »f PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER © City of Carlsbad Bldg Inspection Request For 01/31/2005 Permit* CB043917 Title ANGEL RES 378 SF GAME ROOM ADD Description Inspector Assignment PY Type RESDNTL Sub Type RAD Job Address 1110 CHINQUAPIN AV Suite Lot 0 Location OWNER ANGEL JOE&JUANITA Owner ANGEL JOE&JUANITA Remarks Phone 0000000000 Inspector Total Time CD Description 34 Rough Electric Requested By N/A Entered By JANEAN Act Comment Associated PCRs/CVs Inspection History Date Description Act 01/18/2005 13 Shear Panels/HDs AP 01/18/2005 15 Roof/Reroof AP 12/22/2004 11 Ftg/Foundation/Piers NS 12/21/2004 11 Ftg/Foundation/Piers AP 12/21/2004 12 Steel/Bond Beam WC PY Insp Comments PD PD PY ALREADY DONE PY CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE (760) 602 2700 1635 FARADAY AVENUE TIME LOCATION PERMIT NO FOR INSPECTION CALL/760) 602 2725 RE INSPECTION FEE DUE'? FOR FORTHER INFORMATION CONTACT YES PHONE CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 01/28/2005 Permit* CB043917 Title ANGEL RES 378 SF GAME ROOM ADD Description Type RESDNTL Sub Type RAD Job Address 1110 CHINQUAPIN AV Suite Lot 0 Location OWNER ANGEL JOE&JUANITA Owner ANGEL JOE&JUANITA Remarks PM PLEASE Inspector Assignment PY Phone 0000000000 Inspector Total Time CD Description 34 Rough Electric 39 FinaLEIectrical Requested By NA Entered By CHRISTINE Act Comment " LA- Associated PCRs/CVs Inspection History Date Description Act Insp Comments 01/18/2005 13 Shear Panels/HDs AP PD 01/18/2005 15 Roof/Reroof AP PD 12/22/2004 11 Ftg/Foundation/Piers NS PY ALREADY DONE 12/21/2004 11 Ftg/coundation/Piers AP PY 12/21/2004 12 Steel/Bond Beam WC PY CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE (760) 602 2700 1635 FARADAY AVENUE 4 f FOR INSPECTION CALL (760) 602 2725 RE INSPECTION FEE DUE'? f / FOR FURJHEXlNF<$RMATION/CONTACT YES PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER ® EsGil Corporation In Partnership with government for (BuiCding Safety DATE December 6, 2004 a APPLICANT a JURIS JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 04 3917 SET IV PROJECT ADDRESS 1110 Chinquapin Avenue PROJECT NAME Angel Addition/Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction s building codes The plans transmitted herewith will substantially comply with the jurisdiction s building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant s copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS OK to issue with applicant replacing sheets 1&2 in set III with the new sheets 1 & 2 marked set IV Received one set only Applicant is carrying perforated plans to the City By Bryan Zuppiger Enclosures Esgil Corporation D GA D MB D EJ D PC LOG trnsmtl 9320 Chesapeake Drive Suite 208 + San Diego California 92123 + (858)560 1468 +• Fax (858) 560 1576 EsGil Corporation In (Partnership with government for (BuiUing Safety DATE December 2, 2004 a APPLICANT JURISDICTION Carlsbad a ~PLAN REVIEWER a FILE PLAN CHECK NO O4 3917 SET III PROJECT ADDRESS 1110 Chinquapin Avenue PROJECT NAME Angel Addition/Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction s building codes The plans transmitted herewith will substantially comply with the jurisdiction s building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant s copy of the check list has been sent to Challenger Construction Company 4310 La Portalada Drive Carlsbad CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed I Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Challenger Construction Company Telephone # 760 672 2700 Date contacted cJzJo^by ^ ) (M^*) Fax# Mail ^-^elephone -^ Fax In Person I REMARKS Please imprint all notes and details on the plans Pencil is not approved With the exception of number 6 all corrections still apply By Bryan Zuppiger Enclosures Esgil Corporation D GA D MB D EJ D PC 11/23/04 trnsmtldot 9320 Chesapeake Drive Suite 208 + San Diego California 92123 + (858)560 1468 + Fax (858) 560 1576 Carlsbad 04 3917 December 2, 2004 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PLAN CHECK NO O4-3917 PROJECT ADDRESS 1110 Chinquapin Avenue SET III DATE PLAN RECEIVED BY " DATE RECHECK COMPLETED ESGIL CORPORATION 11/23/04 December 2, 2004 REVIEWED BY Bryan Zuppiger FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code Uniform Plumbing Code Uniform Mechanical Code National Electrical Code and state laws regulating energy conservation noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department Engineering Department or other departments The following items listed need clarification modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3 1997 Uniform Building Code the approval of the plans does not permit the violation of any state county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to ESGIL CORPORATION B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo Carlsbad 04 3917 December 2, 2004 . PLANS NOTE The items listed below refer to the item numbers from previous list These remaining items have not been adequately addressed The notes in bold at the end of or contained within each item are to emphasize the remaining problem 1 Please make all corrections on the originals and submit two new complete sets of prints to Esgil Corporation 9320 Chesapeake Drive Suite 208 San Diego California 92123 (858) 560-1468 2 The person responsible for their preparation must sign all final sheets of plans (California Business and Professions Code) This applies to all subsequent submittals Only the effected sheets need be submitted I will insert them into the plans • FOUNDATION REQUIREMENTS 15 Dowel the new to existing foundation together Provide details referenced to the plans 17 If required show size, embedment and location of hold down anchors on foundation plan UBC Section 106 3 3 FRAMING 20 Please detail the California framing a) Show the ledger size and connection to the roof sheathing b) Show all member sizes 21 For Conventional Light-Frame Construction buildings shall be provided with exterior and interior braced wall lines Spacing shall not exceed 25 for Seismic Zone 4 or for wind speeds >80 mph on center in both directions in each story UBC Sections 2320 4 2 and 2320 5 1 and Table 23-IV-C-1 22 Conventional Light-Frame Construction requirements also apply to the portion of the existing where the stucco is being removed 23 Show the following on the plans for the required braced wall panels If the requirements of braced wall panels in conventional light frame construction are not possible provide design calculations from an Engineer or Architect licensed by the State of California a) Show on the plans the location length and type of braced wall panel as per UBC Section 2320 11 3 and Table 23-IV C 1 Braced wall panels are limited to a minimum of 4' in length i) Braced wall panels shall start at not more than 8' from each end of a braced wall line Carlsbad 04 3917 December 2, 2004 b) Interior braced wall panels shall extend to the roof or floor diaphragm level c) Any braced wall panel required by UBC Section 2320 11 3 may be replaced by an alternate braced wall panel UBC Section 2320 11 4 Alternate braced walls may be less than 4' in length but can not exceed 10' in height For alternate braced wall panels in one story buildings show compliance with the following on the plans i) Minimum braced panel length is 2 -8 in width and a maximum height of 10-0 n) Each braced wall panel is sheathed on at least one face with 3/8 plywood sheathing nailed with 8d common or galvanized box nails per 23-II-B-1 and blocked at all plywood edges in) A minimum of two anchor bolts installed in accordance with Section1806 6 between hold down devices iv) An approved hold down device fastened to the foundation and capable of providing an uplift capacity of not less than 1 800 pounds is provided at each panel end v) The foundation that supports the braced panels is continuous across the entire length of the braced wall line and reinforced with a minimum of one # 4 bar top and bottom To speed up the review process note on this list (or a copy) where each correction item has been addressed le plan sheet note or detail number calculation page etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive Suite 208 San Diego California 92123 telephone number of 858/560-1468 to perform the plan review for your project If you have any questions regarding these plan review items please contact Bryan Zuppiger at Esgil Corporation Thank you EsGil Corporation In (Partnership with government for (BuiCding Safety DATE November 8, 2004 OAPPLICANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 04-3917 SET II PROJECT ADDRESS 1 1 1O Chinquapin Avenue PROJECT NAME Angel Addition/ Re mo del The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction s building codes The plans transmitted herewith will substantially comply with the jurisdiction s building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant s copy of the check list has been sent to Challenger Construction Company 4310 La Portalada Drive Carlsbad CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Challenger Construction Company Telephone # 760 672 2700 Date contacted ///1/ajfoy^££ ) MX~^ Fax # "? ^-/^ <9 Mail vTelephone \/ Fax Y In Person -JO/O REMARKS By Bryan Zuppiger Enclosures Esgil Corporation D GA D MB D EJ D PC 11/01/04 trnsmtldot 9320 Chesapeake Drive Suite 208 * San Diego California 92123 + (858)560 1468 + Fax (858) 560 1576 Carlsbad O4-3917 November 8, 2004 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PLAN CHECK NO 04-3917 PROJECT ADDRESS 1110 Chinquapin Avenue SET II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 11/01/04 November 8, 2004 REVIEWED BY Bryan Zuppiger FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code Uniform Plumbing Code Uniform Mechanical Code National Electrical Code and state laws regulating energy conservation noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department Engineering Department or other departments The following items listed need clarification modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3 1997 Uniform Building Code the approval of the plans does not permit the violation of any state county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to ESGIL CORPORATION B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo Carlsbad O4-3917 November 8, 2004 • PLANS NOTE The items listed below refer to the item numbers from previous list These remaining items have not been adequately addressed The notes in bold at the end of or contained within each item are to emphasize the remaining problem 1 Please make all corrections on the originals and submit two new complete sets of prints to Esgil Corporation 9320 Chesapeake Drive Suite 208 San Diego California 92123 (858)560-1468 2 The person responsible for their preparation must sign all final sheets of plans (California Business and Professions Code) This applies to all subsequent submittals Only the effected sheets need be submitted I will insert them into the plans . FIRE PROTECTION 6 When the valuation of a room addition or repair exceeds $1 000 show locations of permanently wired smoke detectors with battery backup in the new and existing construction except that smoke detectors added at existing construction need only be battery powered UBC Section 310 9 1 2 i a) Inside each bedroom b) Centrally located m corridor or area giving access to sleeping rooms c) In rooms adjacent to hallways serving bedrooms when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway • FOUNDATION REQUIREMENTS 15 Dowel the new to existing foundation together Provide details referenced to the plans 17 If required show size, embedment and location of hold down anchors on foundation plan UBC Section 10633 FRAMING 20 Please detail the California framing a) Show the ledger size and connection to the roof sheathing b) Show all member sizes 21 For Conventional Light-Frame Construction buildings shall be provided with exterior and interior braced wall lines Spacing shall not exceed 25 for Seismic Zone 4 or for wind speeds >80 mph on center in both directions in each story UBC Sections 2320 4 2 and 2320 5 1 and Table 23-IV-C-1 22 Conventional Light-Frame Construction requirements also apply to the portion of the existing where the stucco is being removed Carlsbad O4-3917 November 8, 2004 23 Show the following on the plans for the required braced wall panels If the requirements of braced wall panels in conventional light frame construction are not possible provide design calculations from an Engineer or Architect licensed by the State of California a) Show on the plans the location length and type of braced wall panel as per UBC Section 2320 11 3 and Table 23-IV-C-1 Braced wall panels are limited to a minimum of 4' m length i) Braced wall panels shall start at not more than 8' from each end of a braced wall line b) Interior braced wall panels shall extend to the roof or floor diaphragm level c) Any braced wall panel required by UBC Section 2320 11 3 may be replaced by an alternate braced wall panel UBC Section 2320 11 4 Alternate braced walls may be less than 4' in length but can not exceed 10' in height For alternate braced wall panels in one story buildings show compliance with the following on the plans i) Minimum braced panel length is 2 -8 in width and a maximum height of 10 0 ii) Each braced wall panel is sheathed on at least one face with 3/8 plywood sheathing nailed with 8d common or galvanized box nails per 23-II-B-1 and blocked at all plywood edges in) A minimum of two anchor bolts installed in accordance with Section1806 6 between hold down devices iv) An approved hold down device fastened to the foundation and capable of providing an uplift capacity of not less than 1 800 pounds is provided at each panel end v) The foundation that supports the braced panels is continuous across the entire length of the braced wall line and reinforced with a minimum of one # 4 bar top and bottom To speed up the review process note on this list (or a copy) where each correction item has been addressed i e plan sheet note or detail number calculation page etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive Suite 208 San Diego California 92123 telephone number of 858/560-1468 to perform the plan review for your project If you have any questions regarding these plan review items please contact Bryan Zuppiger at Esgil Corporation Thank you ceanside 04-1474 1/8/04 VALUATION AND PLAN CHECK FEE JURISDICTION Oceanside PLAN CHECK NO 04-1474 PREPARED BY Chuck MendenhaU DATE 11/8/04 BUILDING ADDRESS 219 N Home St, Suite 'B' BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VN BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 552 OS 1QQ1 1IRT Rllllrimn Doi-mi)- Poo tr Valuation Multiplier 2900 91 Reg Mod VALUE ($) 17499 17,499 $18900 1991 UBC Plan Check Fee Type of Review Repetitive Fee Repeats Complete Review D Other r- Hourly D Structural Only Hour* Esgil Plan Review Fee $12285 $9828 Comments Sheet 1 of 1 macvalue doc EsGil Corporation In (Partnersfitp with government for Quitting Safety DATE October 29, 2004 a APPUCANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 04-3917 SET I PROJECT ADDRESS 1110 Chinquapin Avenue PROJECT NAME Angel Addition/ Remodel I | The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction s building codes I | The plans transmitted herewith will substantially comply with the jurisdiction s building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person • The applicant s copy of the check list has been sent to Challenger Construction Company 4310 La Portalada Drive Carlsbad CA 92008 I I Esgil Corporation staff did not advise the applicant that the plan check has been completed B Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Challenger Construction Company Telephone # 760 672 2700 Date contacted/ofe (by (^ ) (MiK£) Fax# Mail ^Telephone ^ Fax.X In Person REMARKS By Bryan Zuppiger Enclosures Esgil Corporation D GA D MB D EJ D PC 10/19/04 trnsmOdot 9320 Chesapeake Drive Suite 208 4 San Diego California 92123 4 (858)560 1468 * Fax (858) 560 1576 Carlsbad O4 3917 October 29, 20O4 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO O4-3917 JURISDICTION Carlsbad PROJECT ADDRESS 1110 Chinquapin Avenue FLOOR AREA See Below STORIES 1 Dwelling addition 378' DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEW COMPLETED October 29, 2004 HEIGHT 14' at east elev sheet 3 DATE PLANS RECEIVED BY ESGIL CORPORATION 10/19/04 PLAN REVIEWER Bryan Zuppiger FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code Uniform Plumbing Code Uniform Mechanical Code National Electrical Code and state laws regulating energy conservation noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department Engineering Department Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24) which adopts the following model codes 1997 UBC 2000 UPC 2000 UMC and 1999 NEC (all effective 11/1/02) The above regulations apply to residential construction regardless of the code editions adopted by ordinance The following items listed need clarification modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3 1997 Uniform Building Code the approval of the plans does not permit the violation of any state county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e. plan sheet number, specification section, etc Be sure to enclose the marked up list when you submit the revised plans Carlsbad O4-3917 October 29, 20O4 • PLANS 1 Please make all corrections on the original tracings as requested in the correction list Submit two sets of plans for residential projects For expeditious processing corrected sets can be submitted in one of two ways a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department 1635 Faraday Ave Carlsbad CA 92008 and (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning Engineering and Fire Departments b) Bring one corrected set of plans and calculations/reports to EsGil Corporation 9320 Chesapeake Drive Suite 208 San Diego CA 92123 and (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning Engineering and Fire Departments until review by EsGil Corporation is complete 2 The person responsible for their preparation must sign all final sheets of plans (California Business and Professions Code) 3 Final plans specifications and calculations for designs deviating from conventional wood frame construction shall be signed and sealed by the engineer or architect licensed by the State of California who is responsible for their preparation Specify expiration date of license (California Business and Professions Code) 4 On the cover sheet of the plans specify any items requiring special inspection in a format similar to that shown below UBC Section 106 3 2 • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections the following checked items will also require Special Inspection in accordance with UBC Sec 1701 of the Uniform Building Code ITEM REQUIRED-? REMARKS • EXPANSION/EPOXY ANCHORS YES PER APPROVING REPORT 5 When special inspection is required the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review UBC Section 106 3 5 Please complete the attached form and return with completed plans Carlsbad 04 3917 October 29, 2004 . FIRE PROTECTION 6 When the valuation of a room addition or repair exceeds $1 000 show locations of permanently wired smoke detectors with battery backup in the new and existing construction except that smoke detectors added at existing construction need only be battery powered UBC Section 310912 a) Inside each bedroom b) Centrally located in corridor or area giving access to sleeping rooms c) In rooms adjacent to hallways serving bedrooms when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway NOTE Detectors shall sound an alarm audible in all sleeping areas of the unit UBC Section 310 91 7 On the cover sheet of the plans specify any items that will have a deferred submittal (trusses etc ) Additionally provide the following note on the plans per UBC Sec 106342 Submittal documents for deferred submittal items shall be submitted to the architect or engineer of record who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official • GENERAL RESIDENTIAL REQUIREMENTS 8 Glazing in the following locations should be of safety glazing material in accordance with Section 2406 4 (see exceptions) a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors b) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position • ROOFING 9 Show the required ventilation for attics The minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents) Show area required and area provided UBC Section 1505 3 10 Where eave vents are installed insulation shall not block the free flow of air A minimum of 1 of air space shall be provided between the insulation and the roof sheathing To accommodate the thickness of insulation plus the required 1 clearance member sizes may have to be increased for rafter-ceiling joists UBC Section 1505 3 Carlsbad 04-3917 October 29, 2004 11 Note on the plans Attic ventilation openings shall be covered with corrosion-resistant metal mesh with mesh openings of 1/4-inch in dimension UBC Section 1505 3 12 Show a 22x30 access from the existing attic to the new attic • FOUNDATION REQUIREMENTS 13 Dimension foundations per UBC Table 18-l-C Floors Footing Supported Thickness Width Depth Stemwall 16 12 12 6 14 The following anchor bolt requirements shall apply in Seismic Zones 3 and 4 per UBC Section 1806 6 1 a) Plate washers (minimum size of 2 x 2 x 3/16 ) shall be used on each anchor bolt 15 Dowel the new to existing foundation together Provide details referenced to the plans 16 Specify size ICBO number and manufacturer of power driven pins expansion anchors or epoxy anchors Show edge and end distances and spacing UBC Section 10633 17 If required show size embedment and location of hold down anchors on foundation plan UBC Section 106 3 3 18 If hold downs are required note on plan that hold down anchors must be tied in place prior to foundation inspection UBC Section 108 5 2 • FRAMING 19 Provide truss details and truss calculations for this project Or submit a deferral 20 Please detail the California framing a) Show the ledger size and connection to the roof sheathing b) Show all member sizes ; 21 For Conventional Light-Frame Construction buildings shall be provided with exterior and interior braced wall lines Spacing shall not exceed 25 for Seismic Zone 4 or for wind speeds >80 mph on center in both directions in each story UBC Sections 2320 4 2 and 2320 5 1 and Table 23 IV C-1 Carlsbad 04 3917 October 29, 2004 22 Conventional Light-Frame Construction requirements also apply to the portion of the existing where the stucco is being removed 23 Show the following on the plans for the required braced wall panels If the requirements of braced wall panels in conventional light frame construction are not possible provide design calculations from an Engineer or Architect licensed by the State of California a) Show on the plans the location length and type of braced wall panel as per UBC Section 2320 11 3 and Table 23-IV-C-1 Braced wall panels are limited to a minimum of 4' in length i) Braced wall panels shall start at not more than 8 from each end of a braced wall line b) Interior braced wall panels shall extend to the roof or floor diaphragm level c) Any braced wall panel required by UBC Section 2320 11 3 may be replaced by an alternate braced wall panel UBC Section 2320 114 Alternate braced walls may be less than 4' in length but can not exceed 10' in height For alternate braced wall panels in one story buildings show compliance with the following on the plans i) Minimum braced panel length is 2 -8 in width and a maximum height of 10-0 n) Each braced wall panel is sheathed on at least one face with 3/8 plywood sheathing nailed with 8d common or galvanized box nails per 23-II-B-1 and blocked at all plywood edges in) A minimum of two anchor bolts installed in accordance with Section 1806 6 between hold down devices iv) An approved hold down device fastened to the foundation and capable of providing an uplift capacity of not less than 1 800 pounds is provided at each panel end v) The foundation that supports the braced panels is continuous across the entire length of the braced wall line and reinforced with a minimum of one # 4 bar top and bottom 24 Detail all shear transfer connections from the roof diaphragms to braced walls UBC Section 2315 25 Specify nail size and spacing for the roof diaphragm Specify plywood and/or particle board thickness grade and panel span rating UBC Table 23-II-E-1 Carlsbad O4-3917 October 29, 20O4 • MECHANICAL (UNIFORM MECHANICAL CODE) 26 Every habitable room within a dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70 degrees F at 3 feet above the floor in all habitable rooms Show basis for compliance UBC Sec 31011 • ELECTRICAL (NATIONAL ELECTRICAL CODE) 27 Show on the plan the amperage of the electrical service the location of the service panel and the location of any sub-panels If service is over 200 amps submit single line diagram panel schedule and load calculations 28 For a single-family dwelling unit show that at least one receptacle outlet accessible at grade level will be installed outdoors NEC Art 210-52 (e) This receptacle must be GFCI protected • ENERGY CONSERVATION 29 Note on the plans The manufactured windows shall have a label attached certified by the National Fenestration Rating Council (NFRC) and showing compliance with the energy calculations To speed up the review process note on this list (or a copy) where each correction item has been addressed i e plan sheet note or detail number calculation page etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive Suite 208 San Diego California 92123 telephone number of 858/560-1468 to perform the plan review for your project If you have any questions regarding these plan review items please contact Bryan Zuppiger at Esgil Corporation Thank you Carlsbad 04-3917 October 29, 20O4 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No 04-3917 Job Address or Legal Description 111O Chinquapin Avenue OwnerCff£^v?£XM6 tf*JG&-Address llfO You are hereby notified that in addition to the inspection of construction provided by the Building Department an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego Los Angeles or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate materials structural changes or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet (over) Carlsbad O4-3917 October 29, 2O04 JSPECIALCINSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION we> PLAN CHECK NUMBER /) ^'3 ef/ ^ OWNER'S NAME I as the owner or agent of the owner (contractors may not employ the special inspector) certify that I or the architect/engineer of record will be responsible for employing the special mspector(s) as required by Uniform Building Code (UBC) Section 1701 1 for the construction project Ipe^tecUaJJhe site lifted above UBC Section 106 3 5 Signed I as the engineer/architect of record certify that I have prepared the following special inspection program as required by UBC Section 106 3 5 for the construction project located at the site listed above E g! s/A h t ct Se I &Slg I reH 1 List of work requiring special inspection [Qbxpansion/Epoxy Anchors 2 Name(s) of mdividual(s) or firm(s) responsible for the special inspections listed above -., , A GfiL (/** t4rte( B C 3 Duties of the special inspectors for the work listed above A <j en B Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site Carlsbad 04 3917 October 29, 2004 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO 04-3917 PREPARED BY Bryan Zuppiger DATE October 29, 2004 BUILDING ADDRESS 1110 Chinquapin Avenue BUILDING OCCUPANCY R3 TYPE OF CONSTRUCTION VN BUILDING PORTION dwelling addition Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 378 r cb Valuation Multiplier City Valuation By Ordinance Reg Mod VALUE ($) 41 580 41,580 Bldg Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review l~l Repetitive Fee ~^~| Repeats Complete Review D Other i—I Hourly fj Structural Only Hour Esgil Plan Review Fee $309 71 $201 31 $17344 Comments macvalue doc City of Carlsbad Public Works — Engineering BUILDING PLANCHECK CHECKLIST DATE BUILDING AD'DRES PROJECT DESCRIPTION ASSESSOR S PARCEL NUMBER 1sO\>EST VALUE ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans information and/or specifications provided in your submittal therefore any changes to these items after this date including field modifications must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to build D A Right of Way permit is required prior to construction of the following improvements DENIAL Please see the attached report of deficiencies marked with D Make necessary corrections to plans or specifications for compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review By By By Date Date Date // By FOR OFFICIAL USE ONLY INEERING AUTHORIZATION TO ISSUE BUILDING PERMIT Date ATTACHMENTS L! Dedication Application *— Dedication Checklist LJ Improvement Application D Improvement Checklist D Neighborhood improvement Agreement D Grading Permit Application L Grading Submittal Checklist LI Right of Way Permit Application [] Right of Way Permit Submittal Checklist ~~ and Information Sheet ENGINEERING DEPT CONTACT PERSON Name KATHLEEN M FARMER City of Carlsbad Address 1635 Faraday Avenue Carlsbad CA 92008 Phone (760) 602 2741 CFD INFORMATION Parcel Map No Lots Recordation Carlsbad Tract CA 9200^ 7314 • (76O) 6O2 2720 « FAX (760) BUILDING PLANCHECK CHECKLIST RD n 3 D SITE PLAN 1 Provide a fully dimensioned site plan drawn to scale Show A/North Arrow Jx' Right of Way Width & Adjacent Streets & Proposed Structures /'Ox" Driveway widths Existing Street Improvements /ys Existing or proposed sewer lateral /D /Property Lines (show all dimensions^! Existing or proposed water service " Easements ^ J/ Existing or proposed irrigation service D D 2 Show on site plan A Drainage Patterns 1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course 2 ADD THE FOLLOWING NOTE Finish grade will provide a minimum positive drainage of 2% to swale 5 away from building B Existing & Proposed Slopes and Topography C Size type location alignment of existing or proposed sewer and water service (s) that serves the project Each unit requires a separate service however second dwelling units and apartment complexes are an exception D Sewer and water laterals should not be located within proposed driveways per standards 3 Include on title sheet A Site address B Assessor s Parcel Number C Legal Description For commercial/industrial buildings and tenant improvement projects include total building square footage with the square footage for each different use existing sewer permits showing square footage of different uses (manufacturing warehouse office etc ) previously approved EXISTING PERMIT NUMBER DESCRIPTION Show all existing use of SF and new proposed use of SF Example Tenant Improvement for 3500 SF of warehouse to 3500 SF of office \F m rtK thy\MASTERS\B Id g PI h k Ckl t F m (G ) d BUILDING PLANCHECK CHECKLIST ND1° 2 D D ,RD DISCRETIONARY APPROVAL COMPLIANCE 4a Project does not comply with the following Engineering Conditions of approval for Project No n 4b All conditions are in compliance Date DEDICATION REQUIREMENTS 5 Dedication for all street Rights of Way adjacent to the building site and any storm dram or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 15,000 pursuant to Carlsbad Municipal Code Section 18 40 030 Dedication required as follows Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 1/2 x 11 plat map and submit with a title report All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit Attached please find an application form and submittal checklist for the dedication process Submit the completed application form with the required checklist items and fees to the Engineering Department in person Applications will not be accept by mail or fax Dedication completed by Date IMPROVEMENT REQUIREMENTS 6a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 75.000 pursuant to Carlsbad Municipal Code Section 18 40 040 Public improvements required as follows Attached please find an application form and submittal checklist for the public improvement requirements A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process The completed application form and the requirements on the \K thy\MASTERS\B Id g PI h k Cki t F BUILDING PLANCHECK CHECKLIST ., ST D D D checklist must be submitted in person Applications by mail or fax are not accepted Improvement plans must be approved appropriate securities posted and fees paid prior to issuance of building permit Improvement Plans signed by Date D D D 6b Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 1840 Please submit a recent property title report or current grant deed on the property and processing fee of $ 360 00 so we may prepare the necessary Neighborhood Improvement Agreement This agreement must be signed notarized and approved by the City prior to issuance of a Building permit Future public improvements required as follows 6c Enclosed please find your Neighborhood Improvement Agreement Please return agreement signed and notarized to the Engineering Department Neighborhood Improvement Agreement completed by Date D 6d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11 06 030 of the Municipal Code O O 7a Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities in cubic yards (cut fill import export and remedial) This information must be included on the plans D D D 7b Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit Grading Inspector sign off by Date 7c Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) K thy\MASTERS\B Id g I h k Okl I m (G ) d 4 BUILDING PLANCHECK CHECKLIST ,ST gND 3RD U n G 7d No Grading Permit required HJ n L~H 7e If grading is not required write No Grading on plot plan MISCELLANEOUS PERMITS I] D D 8 A RIGHT OF-WAY PERMIT is required to do work in City Right of Way and/or private work adjacent to the public Right of Way Types of work include but are not limited to street improvements tree trimming driveway construction tying into public storm dram sewer and water utilities Right of Way permit required for INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area you need to contact the Carlsbad Municipal Water District located at 5950 El Cammo Real Carlsbad CA 92008 District personnel can provide forms and assistance and will check to see if your business enterprise is on the EWA Exempt List You may telephone (760) 438 2722 extension 7153 for assistance Industrial Waste permit accepted by Date D D D 10 NPDES PERMIT Complies with the Citys requirements of the National Pollutant Discharge Elimination System (NPDES) permit The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit whichever occurs first CH D D 11 Q Rserrjifed fees are attached J^TNo fees required WATER METER REVIEW D G D 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low flow conditions If it is oversized for the life of the meter the City will not accurately bill the owner for the water used • All single family dwelling units received standard 1 service with 5/8 service i r\K hy\MAS ERS\B Id g PI h k wkl t F m (G ) d iST ,ND ,RD D D 12b BUILDING PLANCHECK CHECKLIST • If owner/developer proposes a size other than the standard then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm) A typical fixture count and water demand worksheet is attached Once the gpm is provided check against the meter sizing schedule to verify the anticipated meter size for the unit • Maximum service and meter size is a 2 service with a 2 meter • If a developer is proposing a meter greater than 2 suggest the installation of multiple 2 services as needed to provide the anticipated demand (manifolds are considered on case by case basis to limit multiple trenching into the street) Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval The developer must provide these calculations Please follow these guidelines 1 If the project is a newer development (newer than 1998) check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets If so at the water meter station the demand in gpm may be listed there Irrigation services are listed with a circled I and potable water is typically a circled W The irrigation service should look like STA1+00 Install 2 service and 5 meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course) then the applicant must provide irrigation calculations for estimated worst case irrigation demand (largest zone with the farthest reach) Typically Larry Black has already reviewed this if landscape plans have been prepared but the applicant must provide the calculations to you for your use Once you have received a good example of irrigation calculations keep a set for your reference In general the calculations will include • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PS!) « Worse case zone (largest farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA) As long as the project is located within the City recycled water \F m K th \MASTERS\B d g PI k Okl I F nn (Q BUILDING PLANCHECK CHECKLIST .,ST pND qRD service boundary the City intends on switching these irrigation services/meters to a new recycled water line in the future Q CH C 12c Irrigation Use (where recycled water is available) 1 Recycled water meters are sized the same as the irrigation meter above 2 If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development For subdivisions this should have been identified and implemented on the improvement plans Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees However if they front a street which the recycled water is there but is not live (sometimes they are charged with potable water until recycled water is available) then the applicant must pay the San Diego Water Capacity Charge If within three years the recycled water line is charged with recycled water by CMWD then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund However let the applicant know that we cannot guarantee the refund and they must deal with the SDCWA for this D D D 13 Additional Comments lhy\MAST RS\B Id 9 ! h Gil m (<3 ) d Plan Check No Planner Chris Sexton APN PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Address IMP £. Phone (760) 602-4624 A Type of Project & Use QCU\JL A/)OVxs. Net Project Density Zoning rv~( GeneraVPlan fi L¥T\ Facilities Management Zone (_ DU/AC CFD (in/out) #_Date of participation . Remaining net dev acres Circle One (For non residential development Type of land used created by this permit . ) Legend ^ Item Complete D 'tern Incomplete - Needs your action Environmental Review Required YES NO S^ TYPE DATE OF COMPLETION Compliance with conditions of approval7 If not state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/RESO NO PROJECT NO YES DATE NO J/TYPE OTHER RELATED CASES Compliance with conditions or approval9 If not state conditions which require action Conditions of Approval D Coastal Zone Assessment/Compliance Project site located in Coastal Zone7 YES \^ NO _ CA Coastal Commission Authority7 YES _ NO _ If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive Suite 103 San Diego CA 92108-4402 (619)7672370 Determine status (Coastal Permit Required or Exempt) £vr; C/V? Coastal Permit Determination Form already completed7 If NO complete Coastal Permit Determination Form now Coastal Permit Determination Log # _ YES NO Follow-Up Actions 1) Stamp Building Plans as Exempf or "Coastal Permit Required (at minimum Floor Plans) 2) Complete Coastal Permit Determination Log as needed £j D D Inclusionary Housing Fee required YES NO *-^ (Effective date of Inclusionary Housing Ordinance May 21 1993) Data Entry Completed7 YES NO (A/P/Ds Activity Maintenance enter CB# toolbar Screens Housing Fees Construct Housing Y/N Enter Fee UPDATE') Site Plan H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 D DDD 1 Provide a fully dimensional site plan drawn to scale Show North arrow property lines easements existing and proposed structures streets existing street improvements right of v\a\ width dimensional setbacks and existing topographical lines (including ail side and rear \arc slopes) 2 Provide legal description of property and assessor's parcel number Policy 44 - Neighborhood Architectural Design Guidelines CTD D 1 Applicability YES NO ~^ D D D 2 Project complies YES NO Zoning D 1 Setbacks Front Intenor Side Street Side Rear Top of slope O 2 Accessory structure setbacks Front Intenor Side Street Side Rear Structure separation D 3 Lot Coverage ^ ' Required £K>' Required e>'5" Required Required J(a> Required :ks Required Required Required / Reauired / Required / Reauired^ VO?b Shown ^V'G Shown /fV Shown Shown Q-l ' Shown , Shown ^ / Shown ^^ Shownx^" ShcMrn Shown Shown ^ ¥0/* 4 Height Required 3D Spaces Required _. Shown ^C^ Shown5 Parking (breakdown by uses for commercial and mdustnal projects required) Residential Guest Spaces Required Shown Additional Comments^) R^i S Cl£\Q Q o OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE H \ADMlN\COUNTER\BldgPlnchkRevChklst Rev 8/01 1 r Tl M ]2 Ol S to 0 oS o 3 CO Tl S 2J O o 00i— m o o O m CO "S a 3 ID ICD 2>mHz D o O > CnmpuTrus Inc I A. jy Jt yk -^ MANUFACTURING ENGINEERING COMPUTER SYSTEMS 1307 W Sixth St, No 114 • Corona, California 91720 • Tel (714) 734 1302 Escondido Roof Truss P 0 Box 1625 San Marcos, CA 92079-1625 CompuTrus standard engineering may be used for designs up to two (2) pitches higher For example, a 6/12 design may be used for up to an 8/12 design This applies only to pitched top chord and flat bottom chord trusses If you have any further questions regarding this matter, please feel free to call Very truly yours, Scott R Carroll, P E Vice President COMPUTRUS, INC SRC/fe CO " w i c 9 *3 II» «m Si_x i 0m CO w O 2 ^O wO N5 f1 ^ N5 fe i 66 *»5 :ill; =? -^o a O O BffffC MI 52ia ff^i8jfl«ii M'l'ISfffJ1" j l^85i*l5l"lll BSI ^ ^i?dPil s' '• §sa »?H«?l*8iri=fi [tM «| ?3*l!?:»f« II' a|{ *|J|e 5II1I if IS fi §fl 1 •!i ilfl III wmD w.^k 2 eno CO 00 0 CD -J 73m ro 2 V1 Dm wO D 3 0 0 ^00 T] m z 0 o> Tl fl r*F D 03 ^F oc §03 oo < 2 < JO o CO 3 Om zo < B CO § K UJ O o U _0_ IS"o €