HomeMy WebLinkAbout1187 Mariposa Rd; ; CBR2018-0118; Permit('city of
Carlsbad
Residential Permit
Print Date: 11/05/2018 Permit No: CBR2018-0118
Job Address:
Permit Type:
Parcel No:
Vall;atfon:
Occupancy Group:
# Dwelling Units:
Bedrooms:
1187 Mariposa Rd
BLDG-Residential
2122213300
$53,809.81
Work Class;
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Addition Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Closed -Finaled
01/16/2018
04/11/2018
TFraz
Plan Check#:
Final
Inspection: 11/5/2018 9:18:lOAM
Project Title:
Description: JACKSON: 62 SF 1 STORV ADDITION// 7 SF GARAGE CONVERSION TO HABITABLE SPACE// 924 SF INTERIOR REMODEL
Owner: Contractor:
MICHAELENE & FRED MOONEY & OTT
1187 Mariposa Rd
JACKSON DESIGN AND REMODELING
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Carlsbad, CA 92011-4205
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
$B1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
SWPPP INSPECTION FEE TIER 1-Medium BLDG
SWPPP PLAN REVIEW FEE TIER 1-MEDIUM
Total Fees: $1,369.32 Total Payments To Date: $1,369.32
4797 Mercury St, B
San Diego, CA 92111-2122
619-442-6125
Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. lf you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES lT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
$0.00
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
$423.72
$296.60
$43,00
$170.00
$52.00
$80.00
$3.00
$7.00
$238.00
$56.00
'{_ Cicyof
Carlsbad
Building Permit Application PlanCheckNo. c..b~\$3-o{lB
1635 Faraday Ave., Garlsbad, CA 92008
Ph: 780-802,27:1.9 Fax: 760-602-8558
email: bullding@carlsbadca.gov
www.carlsbadca.gov
Est. Value <.:-,,-.,<::; ~
t,o
Date -I(.,.-\
JOB ADDRESS SUITE#/SPACE#/UNIT# APN 2.-1 '2.. i:z.. \ -i 3 00
CT/PROJECT# TENANT BUSINESS NAME~----------,o-,-,~,-.-. TY~,,~-o-,-,-. -GROUP
\-
EXISTING USE PROPOSED USE
APPLICANT NAME (Primary Contact)
0 STUA
FAA
ADDRESS
CITY STATE
PHONE FAA
EMAIL
GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE
YES □# __ NO □
ZIP '1'2-11S
FAA
EMAIL
CONmACTOR BUS. NAME 'T 0-,(,,~Q'(\
ADDR.2\--=\-'\ -=t-~.Q,,'( W'(
ZIP CITY ~\J\ Q
EMAIL
STATE LIC. #
t.\\\
FIRE SPRINKLERS
YES □ NOD
(Sec. 7031.5 Business and P_rofessions Code: Any City or County which requires a permit to. c_onstruct, alter, improve, demolish or repair any structure, p_rior to its issuance, also requires the applicant for such permit to file a sip;ned statement that he is licensed pursuant to the prov1s1ons of the Contractor's License LawjChapter 9, commending with Section 7000 of D1v1s1on 3 of the B_usiness and Professions Code} or fuat he 1s exempt therefrom, and the basis for the alleged exemption. Any violation of Section 031.5 by any applicant for a permit subJects the applicant to a
civil penalty of not more than five hundred dollars {$500}).
WORKER$' COMPENSATION
Workers' Compensation Declaration: I hereby affirm under penalty of peijury one of the following declarations:
0 I have and will maintain a certificale of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued
~ I have and will maintain war ' comp nsation, as required by Section 3700 of the Labor Code, for the _performancy'1)jf~ fo""1~h~e~is issued. My workers' compens1911.. in rlnce ar\e nd policy
number are: Insurance Co .J::iJZ:A;t'.~~---------------Policy No. __ -_J l~V~_. T_=LY\_,_,LJ=~-l'----Exp1rat1on Dale -~U=--1-~--l--'-'---
This section need not be completed if the permit is for one hundred dollars ($100) or less. 0 Certificate of Exemplion: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' comp sation coverage · unlawful, and shall subjecl an employer to criminal penallies and civil fines up to one hundred thousand dollars (& 100,000), in
addition to the cost of compensation, damages vi d for in of the Labor code, interest and attorney's fees.
,..S CONTRACTOR SIGNATURE
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
□ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)
□ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law),
□ I am exempt under Section _____ ,Business and Professions Code for this reason
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No
2. I (have/ have not) signed an application for a building permit for the proposed work,
3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number)
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated {include name I address I phone/ type of work):
_,6$ PROPERTY OWNER SIGNATURE □AGENT DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? O Yes □ No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUC·T.ION LE'llfDJNG AGENCY
I hereby affirm that there Is a construction lend mg agency for the performance of the work this permit Is issued (Sec 3097 (1) CIvII Code)
Lender's Name Lender's Address
APPLICANT CERTIFICATION
I certify that I have read the application and state that the above lnfonnation Is oorrectand that the lnfonnatlon on the plans is aa:urate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby au~ofize represen~live of ~e Ci~ of Carlsbad In enrer upon ~e above mentioned pruperty for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY ANO KEEP HARMLESS THE CITY OF CARLS BAO
AGAINST ALL LIABILrTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such pennit is not commenced within
180 days from the date of such permit or if the building or ·zec1 by nnit · uspended or abandoned at any time after the work is commen for a period of 180 days (Section 106.4.4 Uniform Building Code).
fl5 APPLICANT'S SIGNATURE DATE \ ,s
PERMIT INSPECTION HISTORY REPORT (CBR2018-0118)
Permit Type: BLDG-Residential Application Date: 01/16/2018 Owner: JERRY JACKSON, MICHAELENE &
FRED MOONEY & OTT
Work Class: Addition Issue Date: 04/11/2018 Subdivision: CARLSBAD TCT#97-14 UNIT#01
MARIANO
Status: Closed -Finaled Expiration Date: 04/29/2019 Address: 1187 Mariposa Rd
Carlsbad, CA 92011-4205
IVR Number: 8921
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Relnspectlon Complete Date Start Date
06/25/2018 06/25/2018 BLDG-17 Interior 061863-2018 Passed Tim Frazee Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/28/2018 06/28/2018 BLDG-17 Interior 062437-2018 Passed Tim Frazee Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Yes
07/24/2018 07/24/2018 BLDG-27 Shower 064790-2018 Passed Tim Frazee Complete
Pan/Tuba
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
07/31/2018 07/31/2018 BLDG-17 Interior 066543-2018 Passed Tim Frazee Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Shower lath OK Yes
10/31/2018 10/31/2018 BLDG-Final 074701-2018 Failed Tim Frazee Reinspection Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structvral Final No
BLDG-Electrical Final GFCI in bathroom defective No
11/06/2018 11/06/2018 BLDG-Final 076166·2018 Passed Tim Frazee Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Bvilding Deficiency Yes
BL~G-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLOG-Electrical Final GFCI in bathroom defective Yes
November 06, 2018 Page 2 of 2
PERMIT INSPECTION HISTORY REPORT (CBR2018-0118)
Permit Type: BLDG-Residential Application Date: 01/16/2018 Owner: JERRY JACKSON, MICHAELENE &
FRED MOONEY & OTT
Work Class: Addition Issue Date: 0411112018 Subdivision: CARLSBAD TCT#97-14 UNIT#01
MARIANO
Status: Closed -Finaled Expiration Date: 04/29/2019 Address: 1187 Mariposa Rd
Carlsbad, CA 92011-4205
IVR Number: 8921
Scheduled Actual Inspection Type Date Start Date Inspection No. Inspection Status Primary Inspector Re Inspection Complete
04/1712018 04117/2018 BLDG-11 066144-2018 Passed Tim Frazee Complete
Foundatlon/Ftg/Pler
a (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-SW-Pre-Con 065146-2018 Passed Tlm Frazee Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
04120/2018 04120/2018 BLDG-81 066663-2018 Passed Tim Frazee Complete
Underground
Combo{11, 12,21,31)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-11 Foundation-Ftg-Piers Yes
(Rebar)
BLDG-12 Steel-Bond Beam Yes
BLDG-21 Yes
Underground-Underfloor
Ph,1mbing
BLDG-31 Yes
Underground-Conduit Wiring
06/0912018 06/09/2018 BLDG-16 067632-2018 Passed Andy Krogh Complete
Roof/ReRoof (Patio)
06/1412018 06/14/2018 BLDG-13 Shear 061026-2018 Passed Tim Frazee Complete
Panela/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/20/2018 06/20/2018 BLDG-84 Rough 061696-2018 Passed Tim Frazee Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
06/22/2018 06/2212018 BLDG-16 Insulation 061868-2018 Passed Tim Frazee Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
November 06, 2018 Page 1 of 2
DATE: 04/02/18
JURISDICTION: CARLSBAD
PLAN CHECK#.: CBR2018-0118
EsG1I
SET II
PROJECT ADDRESS: 1187 MARIPOSA ROAD
□ APPLICANT
yJURIS
PROJECT NAME: SFD ADDITION + REMODEL FOR MOONEY AND OTT
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
TERRY MONTELLO
~ EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contactecl;e-TEl':I': t Telephone#: 619 994 5557
Date contacted!'-__.(b~ ?-Email: PERMITS@PERMITSINMOTION.COM
Mail Telephone Fax In Person
~ REMARKS: Please note that plan set Ill was a partial set. Sheets A-1, A-3.1,A-4.1, A-5.1 and
E-1.1 where added from the partial set to set II. Please correct any additional copies of these
plans.
By: Javier Snider (BD)
EsGil
03/29/18
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: 1/26/2018
JURISDICTION: CARLSBAD
PLAN CHECK#.: CBR2018-0118
✓• EsG1I
.4 '.-:./,H::t11.iit Coinnany
SET: I
PROJECT ADDRESS: 1187 MARIPOSA ROAD
~.f:PPLICANT ,)4 JURIS.
PROJECT NAME: SFD ADDITION + REMODEL FOR MOONEY AND OTT
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
[8J The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
[8J The applicant's copy of the check list has been sent to:
TERRY MONTELLO
D EsGil staff did not advise the applicant that the plan check has been completed.
[8J EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: TERRY Telephone#: 619 994 5557
,;[>ate contacted: I 11/\
~ail /,-elephone Fax
0 REMARKS:
By: Bert Domingo
EsGil
(by:)"(__,) Email: PERMITS@PERMITSINMOTION.COM
In Person
Enclosures:
1/19/2018
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
CARLSBAD CBR2018-0l 18
1/26/2018
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: CBR2018-0118 JURISDICTION: CARLSBAD
PROJECT ADDRESS: 1187 MARIPOSA ROAD
FLOOR AREA:
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 1/26/2018
FOREWORD (PLEASE READ):
STORIES:
HEIGHT:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 1/19/2018
PLAN REVIEWER: Bert Domingo
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC,
2015 UPC, 2015 UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process. please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number. specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
.CARLSBAD CBR2018-0118
1/26/2018
• PLANS
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil is complete.
2. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
3. Plans deviating from conventional wood frame construction shall have the
structural portions signed and sealed by the California state licensed engineer or
architect responsible for their preparation, along with structural calculations.
(California Business and Professions Code). This will be checked on the final..
• FIRE PROTECTION
4. Show locations of permanently wired smoke alarms with battery backup, per
Section R314: Please show on the plans.
a) Inside each bedroom.
b) Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
c) On each story, including basements.
d) Such smoke alarm locations shall comply with the following:
i) They shall be not less than 3' from the door opening of a bathroom.
ii) They shall be at least 20' from a cooking appliance.
iii) They shall be at least 3' from supply registers of heating/cooling
systems.
iv) They shall be at least 3' from the tip of the blade of a ceiling-
mounted fan.
• NOTE: When more than one smoke alarm is required to be installed, the
alarm devices shall be interconnected in such a manner that the actuation of
one alarm will activate all of the alarms in the unit.
. CARLSBAD CBR2018-0l 18
1/26/2018
5. In existing buildings, when alterations, repairs or additions requiring a permit
occur (or when one or more sleeping rooms are added), the dwelling unit shall
be provided with smoke alarms located as required for new dwellings; the
smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms
in existing areas need not be interconnected and hard wired where the
alterations or repairs do not result in the removal of interior wall or ceiling finishes
exposing the structure, unless there is an attic, crawl space, or basement
available which could provide access for hard wiring and interconnection without
the removal of interior finishes. Section R314.8.1.
6. In dwelling units within which fuel-burning appliances are installed (and in
dwelling units having attached garages), show the locations of permanently wired
carbon monoxide alarms with battery backup, per Section R315: Please show
on the plans.
a) Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
b) On each story, including basements.
• NOTE: When more than one carbon monoxide alarm is required to be
installed, the alarm devices shall be interconnected in such a manner that the
actuation of one alarm will activate all of the alarms in the unit.
7. When alterations, repairs or additions are proposed for dwelling units within
which fuel-burning appliances are installed (and in dwelling units having attached
garages), the dwelling unit shall be provided with carbon monoxide alarms
located as required for new dwellings; the carbon monoxide alarms shall be
interconnected and hard wired. Exception: Carbon monoxide alarms in existing
areas need not be interconnected and hard wired where the alterations or repairs
do not result in the removal of interior wall or ceiling finishes exposing the
structure, unless there is an attic, crawl space, or basement available which
could provide access for hard wiring and interconnection without the removal of
interior finishes. Section R315.2.
8. Glazing in the following locations should be shown on the plans as safety glazing
material in accordance with Section R308.4:
a) Glazing in doors. French doors.
b) Glazing in the walls/doors facing or containing bathtubs, showers, hot
tubs, spas, whirlpools, saunas, steam rooms and indoor/outdoor swimming
pools where the bottom exposed edge of the glazing is less than 60" above
the standing surface. Exception: Glazing that is more than 60", measured
horizontally, from the water's edge of a bathtub, hot tub, spa, whirlpool or
swimming pool. See the figure below.
.CARLSBAD CBR2018-0118
1/26/2018
SG
-
i
Bathtub. whirlpool tub
or hot tub~
SG /
.. . --. I / '\
I / \
I \ \ I
I <60in. I •. I ' .,,// ~
j
I!-Plan view
SG
.... l -· 'l
SG = Safety glazing required
Measurements are to exposed glazing
! ' i /
SG
SG
1, <60 in. I <60 in.
. \ ,
\ :' ' I i
I \.. j
Section view
• ROOFS/DECKS/BALCONIES
9. Specify roof material and application. Chapter 9.
l V
SG
l· Flo
0in .
or
a) In California, roofing shall be a fire-retardant roof covering that is at least
Class C. Section R902.1.3.
10. Specify on the plans the following information for the roof materials, per Section
R106.1.1: for the new tile roof.
a) Manufacturer's name and product name/number.
b) ICC approval number, or equal.
11. Show the required ventilation for attics (or enclosed rafter spaces formed where
ceilings are applied directly to the underside of roof rafters). The minimum vent
area is 1/150 of attic area (or 1/300 of attic area if at least 40% (but not more
than 50%) of the required vent is located no more than 3' below the ridge). Show
on the plans the area required and area provided. Section R806.2.
a) When using a radiant barrier, California energy design affects the attic
ventilation area requirement: If using the Prescriptive method for energy
compliance, then the attic vent area must be at the 1/150 area: If using
the Performance method, either the 150 or 300 areas may be used, as
documented on the energy forms. Section RA4.2.1.
12. Enclosed rafter spaces do not require venting if the following specific insulation
design is used, per Sections R806.5/EM3.9.6:
♦ If the insulation is air-permeable and it is installed directly below the roof
sheathing with rigid board or sheet insulation with a minimum R-4 value installed
above the roof sheathing. (or)
♦ If the insulation is air-impermeable and it is in direct contact with the underside
of the roof sheathing. (or)
.CARLSBAD CBR2018-0118
1/26/2018
♦ If two layers of insulation are installed below the roof sheathing: An air-
impermeable layer in direct contact with the underside of the roof sheathing and
an additional layer of air permeable insulation installed directly under the air-
impermeable insulation.
13. Where eave vents are installed, insulation shall not block the free flow of air. A
minimum of 1" of air space shall be provided between the insulation and the roof
sheathing. To accommodate the thickness of insulation plus the required 1"
clearance, member sizes may have to be increased for rafter-ceiling joists.
Section R806.3.
14. Note on the plans: "Attic ventilation openings shall be covered with
corrosion-resistant metal mesh with 1/16" minimum to¼" maximum openings.
Section R806. 1.
• MECHANICAL
15. Detail the dryer exhaust duct design from the dryer to the exterior. The maximum
length is 14 feet with a maximum of two 90-degree elbows or provide the
manufacturer's duct length specification description on the plans: Include the
dryer specifications (manufacturer, model, and fuel type) as well as the duct
description (size and type). CMC Section 504.4.2.
16. Specify on the plans the following information for the fireplace(s):
a) Manufacturer's name/model number and ICC approval number, or equal.
b} Show the height of the factory-built chimney above the roof and the
horizontal clearances per listing approval. Chimneys shall extend at least
3' above the highest point where it passes through a roof and at least 2'
higher than any portion of a building within a horizontal distance of 10
feet. CMC Section 802.5.4.
c) Note on the plans that approved spark arrestors shall be installed on all
chimneys. CRC Section R1003.9.
d} Decorative shrouds shall not be installed at the termination of chimneys
for factory-built fireplaces, except where such shrouds are listed and
labeled for use with the specific system and installed in accordance with
the manufacturer's installation instructions. Section CRC1004.3.
17. Show on the plans that countertop receptacle outlets comply with CEC Article
210.52(C): In kitchens a receptacle outlet shall be installed at each counter
space 12 inches or wider; Receptacles shall be installed so that no point along
the wall line is more than 24 inches; Island and peninsular countertops 12
inches by 24" long (or greater) shall have at least one receptacle. (Counter
top spaces separated by range tops, refrigerators, or sinks shall be
considered as separate counter top spaces).
CARLSBAD CBR2018-0118
1/26/2018
• PLUMBING
18. Show water heater size (1 st hour rating), type, and location on plans. Note: For
both new dwellings and additions the Energy Standards (150.0(n)) requires a gas
input rating of 200,000 Btu for both tank and instantaneous gas water heaters.
(Also) Provide a gas piping design for the gas system.
19. An instantaneous water heater is shown on the plans. Please include a gas pipe
sizing design (isometric or pipe layout) for all gas loads.
a) The gas pipe sizing for a tank type water heater shall be based upon a
minimum 199,000 Btu gas input rating. Energy Standards 150.0(n).
20. Provide a note on the plans: The control valves in showers, tub/showers,
bathtubs, and bidets must be pressure balanced or thermostatic mixing valves.
CPC Sections 408,409, 410.
21. Specify on the plans: Water conserving fixtures: New water closets shall use no
more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8
GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 2.0
GPM of flow. CPC Sections 407,408,411, 412.
22. Specify on the plans whether the existing house was built before or after 1994.
For additions or improvements to a residence built before 1994, note on the
plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons
of water per flush, urinals that use more than one gallon of water per flush,
showerheads that have a flow capacity of more than 2.5 gallons of water per
minute, and interior faucets that emit more than 2.2 gallons of water per minute)
shall be replaced. Certification of compliance shall be given to the building
inspector prior to final permit approval. California SB407.
• ELECTRICAL
23. For a single-family dwelling unit (and for each unit of a duplex), show that at least
one receptacle outlet accessible at grade level will be installed outdoors at the
front and back of the dwelling. CEC Article 210.52(E). This receptacle must be
GFCI protected.
24. A balcony, deck, or porch that is accessible from the interior of the dwelling will
require a minimum of one receptacle outlet. CEC 210.52(E) (3). This receptacle
must be GFCI protected.
CARLSBAD CBR2018-0l 18
1/26/2018
• RESIDENTIAL GREEN BUILDING STANDARDS
The California Building Standards Commission has adopted the Green Building
Standards Code and must be enforced by the local building official. The following
mandatory requirements for residential construction must be included on your plans.
CGC Section 101.3. The Standards apply to newly constructed residential buildings,
along with additions/alterations that increase the building's conditioned area, volume
or size. CGC Section 301.1.1. Provide a sheet on the plans labeled "Green
Building Code Requirements" and include the following notes as applicable.
25. Indoor water use. Show compliance with the following table, per CGC Section
4.303.1.
FIXTURE FLOW RATES
FIXTURE TYPE MAXIMUM FLOW RATE
Water closets 1.28 gallons/flush
Urinals (wall-mounted) 0.125 gallon/flush
Urinals (others) 0.5 gallon/flush
Showerheads 2 gpm@80 psi
Lavatory faucets 1.2 gpm @ 60 psi 1
Kitchen faucets 1.8 gpm@ 60 psi
Metering faucets 0.25 gallons per cycle
1. Lavatory faucets shall not have a flow rate less than 0.8 gpm at 20 psi.
26. Note on the plans that when a shower is provided with multiple shower heads,
the sum of flow to all the heads shall not exceed 2.0 gpm @ 80 psi, or the
shower shall be designed so that only one head is on at a time. CGC Section
4.303.1.3.2.
27. Recycling. Note on the plans that a minimum of 65% of construction waste is to
be recycled. CGC Section 4.408.1.
28. Pollutant control. Note on the plans that VOC's must comply with the
limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and
4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood
Products. CGC Section 4.504.2.
29. Indoor air quality. Note on the plans that bathroom fans shall be Energy Star
rated, vented directly to the outside and controlled by a humidistat. CGC
4.506.1.
CARLSBAD CBR2018-0118
1/26/2018
30. Note on the plans that prior to final inspection the licensed contractor, architect
or engineer in responsible charge of the overall construction must provide to the
building department official written verification that all applicable provisions
from the Green Building Standards Code have been implemented as part of the
construction. CGC 102.3.
• ENERGY CONSERVATION
31. Include on the Title Sheet of the plans the following statement: "Compliance with
the documentation requirements of the 2016 Energy Efficiency Standards is
necessary for this project. Registered, signed, and dated copies of the
appropriate CF1 R, CF2R, and CF3R forms shall be made available at necessary
intervals for Building Inspector review. Final completed forms will be available for
the building owner."
32. Instantaneous water heaters shall have isolation valves on both the cold and the
hot water piping leaving the water heater complete with hose bibs or other fittings
on each valve for flushing the water heater when the valves are closed. ES 110.3
33. All domestic hot water piping to have the following minimum insulation installed:
½" pipe (1/2" insulation);¾" pipe (1" insulation); 1" to 1-½" pipe (1-½"
insulation). CPC 609.11 & ES 150.00)
a) Additionally, the ½" hot water pipe to the kitchen sink, and the cold water
pipe within 5' of the water heater both require 1" minimum insulation. ES
150.00)
• MISCELLANEOUS
34. Please show sections cuts thru the floor plan.
35. The required insulation from the title 24 should be reflected on the sect cuts.
To speed up the review process, note on this list (or a copy) where each correction item has been
addressed, i.e., plan sheet, note or detail number, calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where they
are located in the plans.
• Have changes been made to the plans not resulting from this correction list? Please indicate:
Yes □ No □
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San
Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your
project. If you have any questions regarding these plan review items, please contact Bert
Domingo at EsGil. Thank you.
CARLSBAD CBR2018-0118
'1/26/2018
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: CARLSBAD
PREPARED BY: Bert Domingo
PLAN CHECK#.: CBR2018-0118
DATE: 1/26/2018
BUILDING ADDRESS: 1187 MARIPOSA ROAD
BUILDING OCCUPANCY: R 3
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
CTY ESTIMATE
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code CB By Ordinance
1997 UBC Building Permit Fee ~-~]
1997 UBC Plan Check Fee -... ~J
Type of Review: 0 Complete Review
Reg. VALUE
Mod.
D Structural Only
D Repetitive Fee
-;_] Repeats
D Other
D Hourly
EsGil Fee
f-------11 Hr @ *
Comments: In addition to the above fee, an additional fee of$
$ /hr.) for the CalGreen review.
($)
53,810
53,810
$418.821
$272.231
$238.731
is due ( hour@
Sheet 1 of 1
-----· ... ~-·•---,-. ····•---·••~----
{ Cicyof
Carlsbad
RESIDENTIAL GREEN
BUILDING CODE
STANDARDS MANDATORY
MEASURES
CERTIFICATION
CHECKLIST
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
B-51
This form, signed and completed, and all receipts for the recycled materials shall be
submitted to the Building Inspector prior to Final Inspection.
Site Development Mandatorv
4.106.2 A plan is developed and implemented to manage storm water drainage during construction. w\ 4.106.3 The site shall be planned and developed to keep surface water away from buildings. L. Construction plans shall indicate how site grading or a drainage system will manage all surface water
flows. )
Energy Efficiency
4.201.1 Low-rise residential buildings shall meet or exceed the minimum standard design required by
,I~ the California Energy Standards.
Water Efficiency and Conservation \J
Indoor Water Use
4.303.1 Indoor water use shall be reduced by at least 20 percent using one of the following methods: (X)
1. Water saving fixtures or flow restrictors shall be used. /01/2011
2. A 20 percent reduction in baseline water use shall be demonstrated. ~Gx) 4.303.2 When using the calculation method specified in Section 4.303.1, multiple showerheads shall not
exceed maximum flow rates. 7/01/2011
4.303.3 Plumbing fixtures (water closets and urinals) and fittings (faucets and shower heads) shall (X)
comply with specified performance requirements. 7/01/2011
Outdoor Water Use ' 4.304.1 Automatic irrigation systems controllers installed at the time of final inspection shall be weather-r1-'n)__ based.
Enhanced Durability and Reduced Maintenance v
4.406.1 Joints and openings. Annular spaces around pipes, electric cables, conduits or other openings ;IA<) in plates at exterior walls shall be protected against the passage of rodents by closing such openings
with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. ~,,..--Construction Waste Management Plan /
4.408.1 A minimum of 50 percent of the construction waste generated at the site is diverted to recycle or ~1 ~ salvage. Recycled material receipts from approved recyclers must be attached to this form.
4.408.2 Where a local jurisdiction does not have a construction and demolition waste management (V ordinance, construction waste management plan, per form B-59, shall be submitted for approval to the
enforcina aaencv.
Building Maintenance and Operation A
4.410.1 An operation and maintenance manual shall be provided to the building occupant or owner. /~\_
Environmental Quality v~
Fireplaces
4.503.1 Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed //fe woodstove or pellet stove shall comply with US EPA Phase II emission limits where applicable.
Woodstoves, oellet stoves and fireolaces shall also comolv with annlicable local ordinances. -
8-51 Page 1 of 2 Rev. 11/15
Pollutant Control
4.504.1 Duct openings and other related air distribution component openings shall be covered
v~ during construction.
4.504.2.1 Adhesive, sealants and caulks shall be compliant with VOC and other toxic compound
limits. L (X)
4.504.2.2 Paints, stains and other coatings shall be compliant with VOC limits. V (X)
4.504.2.3 Aerosol paints and coatings shall be compliant with product weighted MIR limits for
ROG and other toxic compounds. (X)
4.504.2.4 Documentation shall be provided to verify that compliant VOC limit finish materials
have been used. (X)
4.504.3 Carpet and carpet systems shall be compliant with VOC limits.
4.504.4 50 percent of floor area receiving resilient flooring shall comply with VOC-emission limits (X)
defined in the Collaborative for High Performance Schools (CHPS) Low-emitting Materials List or
be certified under the Resilient Floor Covering Institute (RFCI) FloorScore program. (X)
4.504.5 Particleboard, medium density fiberboard (MDF) and hardwood plywood used in interior
finish svstems shall comclv with low formaldehvde emission standards.
Interior Moisture Control .
4.505.2 Vapor retarder and capillary break is installed at slab on grade foundations. ~l 4.505.3 Moisture content of building materials used in wall and floor framing is checked before
enclosure.
Indoor Air Quality and Exhaust
4.506.1 Exhaust fans which terminate outside the buildina are crovided in everv bathroom. IJ\A. (Xl .
Environmental Comfort
4.507.1 Whole house exhaust fans shall have insulated louvers or covers which close when the (X)
fan is off. Covers or louvers shall have a minimum insulation value of R-4.2.
J~X)
4.507.2 Duct systems are sized, designed, and equipment is selected using the following
methods:
1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent.
2. Size duct systems according to ACCA 29-D (Manual D) or equivalent
3. Select heatina and coolina eauicment accordina to ACCA 36-S (Manual Sl or eauivalent.
Installer and Special Inspector Qualifications
702.1 HVAC system installers are trained and certified in the proper installation of HVAC (X)
systems.
702.2 Special inspectors employed by the owner must be qualified and able to demonstrate (X)
comcetence in the discicline thev are inscectina.
I, as the professional responsible for this project, certify that, to the best of my knowledge, the mandatory items
listed on this form have been incorporated into the project in order to comply with Title 24, Part 11 of the 2013
California Green Building Standards. All receipts for recycled materials have been attached to this form.
Project Address: I 13~ r,1~ 1 Po SC\-{UJ. Plan Chee~ Number: (P/LZI It -01, a
-Jevr~ .SJI I ;110.._, A<C V \ Print Name: Sig<: 0 11 .... s-ri '
License Number: Date:
8-51 Page 2 of 2 Rev. 11/15