Loading...
HomeMy WebLinkAbout1200 CARLSBAD VILLAGE DR; ; CB070770; Permit06-13-2008 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Mechanical Permit Permit No CB070770 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # PC# Project Title Applicant KELLY BROOKS 405 OAK CARLSBAD 92008 802 7731 1200 CARLSBAD VILLAGE DR CBAD MECH 1561804600 Lot# $000 CITY HALL- REPLACE /UPGRADE HVAC Status Applied Entered By Plan Approved Issued Inspect Area Owner CITY OF CARLSBAD PUBLIC AGENCY 00000 ISSUED 03/21/2007 LSM 06/18/2007 06/18/2007 PC Mechanical Issue Fee Install/Furn/Ducts/Heat Pumps Fee Fireplace Installation Fee Exhaust Fan Fee Installation/Relocation Vent Fee Hood Fee Boiler/Compressor to 15HP Fee Other Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 Total Fees $0 00 Total Payments To Date $0 00 Balance Due $000 LDING PLANS . IN STORAGE .ATTACHED Inspector FINAL A Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO <L8£>~70~>~*1 O EST VAL Plan Ck Deposit Validated By Date L/(LL»v6(r iJr^f Address (include Bldg/Suite tt) Legal Description Assessor's Parcel # Description of Work Business Lot No Subdivision Name/Number fifVld*r __ Existing Use SQ FT 1 #of Stories Name (at this address) Unit No Phase No Orif &(£ Proposed Use # o/Bedrooms Total # of units tt of Bathrooms Name h-rj 'Contractor.* Address | Agent for:CwrSrac'tbrfes[I] Owner ••''OEJ&i City State/Zip Telephone #Fax i Name 14 PROPERTY OWNER Address Cltv Telephone # C Address City State/Zip Telephone #Name ^^"^tyvi^^&CQ^^^fj^f^^^, (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars l$5001) Name State License tt Address License Class City State/Zip City Business License # Telephone tt Designer Name State License tt Address City State/Zip Telephone Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations f~) I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued n I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are Insurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) n CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code interest and attorney's fees SIGNATURE DATE ! DECLARATION .':'.•..'•..• - -. : '..',;' '.. U^.Z. •." Kl.'...:. <C ...J. ..' :: I hereby affirm that I am exempt from the Contractor's License Law for the following reason 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) FM I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) l~l I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement d YES CDNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURED DATE* ON>Qff/ii'p/M^ ,:•• • •• • • , ...••,,;,.:/--•':t''i:s::t!:-:-----'i'i'"::2'?;>":'::::'£?l";::::::.:f:- Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration former risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? O YES (*J NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? C~l YES [Zf NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES GJKNO IF ANY OF THE ANSWERS ARE YES. A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT lf£... CONSTIWCTi^L^^ .•'"'• . •''"'„.'. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code) LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above-information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE. INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenaed for a period of 180 days (Section 106 4 4 Uniform Building Code) APPLICANT'S SIGNATURE ^ HCfl&U (oVfrQV^3 _ DATE 3~ WHITE File YELLOW Applicant PINK Finance City of Carlsbad Bldg Inspection Request For 06/13/2008 Permit* CB070770 Title CITY HALL- REPLACE /UPGRADE Description HVAC Inspector Assignment PC 1200 CARLSBAD VILLAGE DR Lot 0 Type MECH Sub Type Job Address Suite Location OWNER CITY OF CARLSBAD Owner Remarks Phone 7602503604 Inspector Total Time Requested By DAVID Entered By CHRISTINE CD Description 49 Final Mechanica omments Comments/Notices/Holds Associated PCRs/CVs Original PC# Date 06/11/2008 06/10/2008 06/10/2008 06/10/2008 06/10/2008 05/28/2008 05/28/2008 05/27/2008 05/27/2008 05/23/2008 05/19/2008 Insoection Historv Description 23 Gas/Test/Repairs 23 Gas/Test/Repairs 24 Rough/Topout 34 Rough Electric 44 Rough/Ducts/Dampers 15 Roof/Reroof 34 Rough Electric 22 Sewer/Water Service 24 Rough/Topout 34 Rough Electric 43 AirCond/Furnace Set Act AP PA AP AP AP we PA we AP PA PA Insp PC PC PC PC PC PC PC PC PC PC PC Comments NO CARD ON SITE OK- GAS METER INCREASE visual only on roof HOT WATER PIPING ELECT @ NEW PANEL TO COOLING TOWER chilled water piping EsGil Corporation In Partnership with government for Quitting Safety DATE June 14, 20O7 JURISDICTION Carlsbad CTPtAN-REVlEWER a FILE PLAN CHECK NO 07-770 SET III PROJECT ADDRESS 1200 Carlsbad Village Drive PROJECT NAME HVAC Upgrade Carlsbad City Hall The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck I | The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to XI Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person XI REMARKS OK to issue with applicant replacing sheets M-2, M-3,E^&(£^4fi set I with the new sheets M-2 marked Set III, M-3, E-3 & E-4 marked set II /^fely^cNone set only By Bryan Zuppiger Enclosures Esgil Corporation GA D MB D EJ D PC O6/O7/O7 trnsmtl dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4- (858)560-1468 * Fax (858) 560-1576 t , EsGil Corporation In (Partners/tip with government for Quitting Safety DATE April 3O, 2OO7 a APPLICANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 07-770 SET II PROJECT ADDRESS 1200 Carlsbad Village Drive PROJECT NAME HVAC Upgrade Carlsbad City Hall The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Kelly Brooks 405 Oak Avenue Carlsbad, CA mr* Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Kelly Brooks Telephone # 760 802 7731 Date contacted 5///X?^by J^S ) Fax # 760 802 7731 720 9562 Mail Telephone Fax j/fn Person REMARKS By Bryan Zuppiger Enclosures Esgil Corporation D GA D MB D EJ D PC 04/18/07 trnsmtl dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad O7-77O April k), 2007 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PLAN CHECK NO O7-77O PROJECT ADDRESS 12OO Carlsbad Village Drive SET II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 04/18/O7 April 3O, 2007 REVIEWED BY Bryan Zuppiger FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit new sets of prints to See Item #1 next sheet. B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes aNo Carlsbad O7-77O April SO, 2007 • PLANS NOTE: The items listed below refer to the item numbers from previous list These remaining items have not been adequately addressed. The notes in bold at the end of or contained within each item are to emphasize the remaining problem. 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Avenue, Carlsbad, CA 92008, and (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 6 The completed and signed MECH-1 forms must be imprinted on the plans Please use the current forms, check both boxes on the first sheet and identify the equipment to be tested and the persons doing the testing on the second sheet. 7 WIRING METHODS AC Cable is not allowed in A, B, E, H, and I occupancies NM cable is restricted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits Unable to locate how this was addressed on the plans. 8 The use of flexible metal conduit as a grounding means must comply with City Policy 84-36 Unable to locate how this was addressed on the plans. 9 No wiring is permitted on the roof of a building and wiring on the exterior of a building requires approval by the Building Official City Policy Unable to locate how this was addressed on the plans. The person responsible for their preparation must sign all final sheets of plans (California Business and Professions Code) To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation Thank you EsGil Corporation In (Partnership with government for Quitting Safety DATE April 3, 20O7 (^APPLICANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO O7-77O SET I PROJECT ADDRESS 120O Carlsbad Village Drive PROJECT NAME HVAC upgrade Carlsbad City Hall The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person IXi The applicant's copy of the check list has been sent to Kelly Brooks 405 Oak Avenue Carlsbad, CA Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Kelly Brooks Telephone # 760 802 7731 Date contacted^/3/07{byx£^3 ) F'ax# 760 Mail Telephone y/^Fax ,/ln Person REMARKS By Bryan Zuppiger Enclosures Esgil Corporation n GA n MB n EJ n PC 03/26/07 trnsmtl dot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576 Carlsbad 07-77O April 3, 2007 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO O7-77O DATE PLANS RECEIVED BY JURISDICTION REMARKS HVAC upgrade only DATE INITIAL PLAN REVIEW COMPLETED April 3, 2007 JURISDICTION Carlsbad DATE PLANS RECEIVED BY ESGIL CORPORATION 03/26/07 PLAN REVIEWER Bryan Zuppiger FOREWORD (PLEASE READ)- This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot Carlsbad O7-770 April 3, 2OO7 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Avenue, Carlsbad, CA 92008, and (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 Provide an analysis of the existing roof framing for the new HVAC equipment that exceeds 400lbs in weight UBC Section 1632 1 3 Submit panel(s) schedule(s) 4 Provide plans, calculations and worksheets to show compliance with current energy standards 5 Provide complete energy designs for the proposed changes in envelope, lighting, and mechanical systems Provide the completed MECH- forms showing energy compliance 6 The completed and signed MECH-1 forms must be imprinted on the plans 7 WIRING METHODS AC Cable is not allowed in A, B, E, H, and I occupancies NM cable is restricted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits 8 The use of flexible metal conduit as a grounding means must comply with City Policy 84-36 9 No wiring is permitted on the roof of a building and wiring on the exterior of a building requires approval by the Building Official City Policy 10 Roof mounted equipment must be screened and roof penetrations should be minimized City Policy 80-6 Carlsbad 07-77O April 3, 2007 The person responsible for their preparation must sign all final sheets of plans (California Business and Professions Code) Final structural plans, specifications and calculations must be signed and sealed by the engineer or architect licensed by the State of California who is responsible for their preparation Please specify the expiration date of license (California Business and Professions Code) To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation Thank you Carlsbad O7-77O April a, 2OO7 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO O7-770 PREPARED BY Bryan Zuppiger DATE April 3, 2007 BUILDING ADDRESS 1200 Carlsbad Village Drive BUILDING II AREA PORTION (Sq Ft) chiller& boiler Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb Valuation Multiplier By Ordinance Reg Mod VALUE ($) Plan Check Fee by Ordinance Type of Review [Repetitive Fee Repeats $18000 Complete Review D Other r-n Hourly Structural Only 1 5 Hours * Esgil Plan Review Fee $14400 Comments macvalue doc B D o I PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CB 07-770 Address Planner _ APN 1200 Carlsbad Village Drive Jo Marguez Phone (760) 602-4619 156-180-46-00 Type of Project & Use_ Zoning R-P-Q City Hall - HVAC Upgrade Net Project Density _General Plan G Facilities Management Zone DU/AC 1 CFD (in/out) #. Circle One _Date of participation Remaining net dev acres (For non-residential development Type of land used created by this permit J Legend Item Complete Environmental Review Required DATE OF COMPLETION Item Incomplete - Needs your action YES NO X TYPE Compliance with conditions of approval9 If not, state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/RESO NO PROJECT NO YES NO X DATE TYPE OTHER RELATED CASES Compliance with conditions or approval7 If not, state conditions which require action Conditions of Approval D Coastal Zone Assessment/Compliance Project site located in Coastal Zone9 YES_ CA Coastal Commission Authority9 YES_ NO. NO X X If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402, (619) 767-2370 Determine status (Coastal Permit Required or Exempt) Habitat Management Plan Data Entry Completed9 YES .NO X If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus ''' * '•''! j ' (A/P/Ds, Activity Maintenance, enter,CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE')-' Inclusionary Housing Fee required YES NO X (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) Data Entry Completed9 YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 Site Plan- Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) Provide legal description of property and assessor's parcel number n n Policy 44 - Neighborhood Architectural Design Guidelines 1 Applicability YES NO 2 Project complies YES NO D Zoning 1 Setbacks Front Interior Side Street Side Rear Top of slope Required. Required. Required Required. Required. Accessory structure setbacks N/A Front Required. Interior Side Required Street Side Required Rear Required. Structure separation Required _Shown _Shown _Shown _Shown Shown Shown Shown. Shown Shown Shown CH 3 Lot Coverage Required.Shown 4 Height Required Shown 5 Parking Spaces Required Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments Correction #1- Will the proposed roof mounted equipment associated with this building permit be screened by an existing parapet wall or is new screening material required? Please see the attached handouts for examples Correction #2- Please show a detail site plan of the building roof top OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER \gjQiy K^ DATE 3- H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 (N) STEEL CURB Ts 2"x6"x3/8" LLH (TYP.). LENGTH TO SUIT CHILLER LENGTH. CHILLER MOUNTING HOLES 05/8 .STEEL CURB SECTION A-A (N) EQUIPMENT (N) VIBRATION ISOLATOR TYPE SLR-4A-1240. MFR: MASON INDUSTRIES. *WELD IN POSITION SEE MFR. RECOMMENDATIONS. \l 6" fr3/16 (N) STEEL CURB Ts 2"x6"x3/8" LLH (TYP.) B-B SCALE: 1-1/2"=1' (N) STEEL CURB Ts 2"x6"x3/8" LLH , XE) 3* THICK a J ( CONCRETE SLAB ( (E) 3" THICK \« CONCRETE A-A SCALE: 1-1/2"=1' THREADED (A36) W/ SIMPSON EPOXY 2-1/2" EMBEDMENT. DRILL DAHL, TAYLOR & ASSOCIATES, INC & MH^JBM^fl» wVUGOTO S631 Pubmr Way. Suite K Corbbad, Cafflbma 92010 Phone NOJ (760) 431-5026 Fax No, (760) 431-5066 Project No. 306006 CHILLER ANCHOR DETAIL, DETAIL 2. SHEET KM TUlf; ffHIflER ANQHOR DETAIL SHEET: SK-I PROJECT NAME: CITY HALL HVAC UPGRADE DATE: /i\ 5-14-08 PROJECT NO: FAG 07-02 REV. DATE - SCALE: AS NOTED UJ UJ Q UJ 3^-i Q 12 V) ^ f£ LU<o =2 S LU•^ o: o:m LU o ^ o i § b > LJJ So o x 5 ° .o_jO Qf 2 5§2SS. ui <^; >( i<llU.IXO oo (TO. O Q. W Q. UJ m C 5 ft X 5 i*« <oO1^!*-i <•w , 1 I ,0 N M£ 2 O ro VPpV 3"