Loading...
HomeMy WebLinkAbout1200 CARLSBAD VILLAGE DR; ; CB131861; Permit11-27-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plumbing/Mechanical/Electrical (PME) Permit Permit No:CB131861 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Reference #• PC# Project Title 1200 CARLSBAD VILLAGE DR CBAD PME 1561804600 Lot# CITY HALL- GEAR REPLACE MAIN SWITCH Status Applied Entered By- Plan Approved Issued' Inspect Area ISSUED 08/05/2013 RMA 11/27/2013 11/27/2013 Applicant. CITY OF CARLSBAD PUBLIC AGENCY 405 OAK AV CARLSBAD CA 92008 760 802-4559 Owner CITY OF CARLSBAD PUBLIC AGENCY 00000 Plumbing Fees Electncal Fees Mechanical Fees Other PME Fees $0 00 $0 00 $0 00 $0 00 TOTAL PERMIT FEES $0 00 Total Fees $0 00 Total Payments To Date $0 00 Balance Due: $0.00 FINAL APPROVAL Inspector Date Clearance NOTICE Please take NOTICE ttiat approval of your project includes the "Imposition" of fees, dedications, resen/ations, or otfier exactions tiereafter collectively refenred to as "fees/exactions" You fiave 90 days from ttie date ttiis permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required infonnation with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attaci<, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project, NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously othenwise expired THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE- IZlPLANNING •ENGINEERING Q BUILDING OFIRE LjHEALTH •HAZMA-r/APCD ^ CiTY OF TARI ^RAH Building Permit Application 1635 Faraday Ave , Carlsbad, CA 92008 Ph 760-602-2719 Fax 760-602-8558 email building@carlsbadca gov www.carlsbadca.gov Plan Check No Est. Value JOBADDRESS mo cmp^w3>n^.kyi CT/PROJECT # |LOT# | PHASE SUITE#/SPACE#/UNiT# lASE"? 'T* OFUNITS 1 # BEDROOMS # BATHROOMS TENANT BUSINESS NAME DESCRIPTION OF WORK: /nc/ude Square Feet of A(i^cte(/>ti'ea(s) EXISTING USE PROPOSED USE GARAGE (SF) APPLICANT NAME^Pr/mary Contact; , PATIOS (SF) DECKS (SF) FIREPLACE YESfltf NOj I AIR CONDITIONING YES I |NO| I FIRE SPRINKLERS YES I |NO| I APPLICANT NAME (Secondary Contact; ADDRESS DfdC A\/e,. ADDRESS CITY STATE FAX CITY STATE ZIP PHONE 7bO'^5i~3PW\ EMAIL EMAIL PROPERTY OWNER NAME „ _ „ CONTRACTOR BUS. NAME ADDRESS ADDRESS CITY STATE ZIP CITY STATE ZIP PHONE FAX PHONE FAX EMAIL EMAIL ARCH/DESIGNER NAME & ADDRESS CITY BUS Lie* (Sec 70315 Business and Professions Code Any City or County VKhich requires a permit to construct, alter, improve, demolish or repair any structure, pnor to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending v^ith Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis forthe alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)) Workers' Compensation Declaration / Aereiiy affinn under penalty of perjury one of the following declarations _ I have and will maintain a certficate of consent to self-insure for workers' compensation as pnjvided by Section 3700 of the Labor Code, for the pertormance of the work for which this pemit is issued j I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, forthe perfonnance of the wori( for which this permit is issued My workers' compensation insurance camer and policy number are Insurance Co Policy No Expiration Date This section need not be completed if the permit is for one hundred dollars ($100) or less I I Certificate of Exemption. I certify that in the pertonnance of the worts for which this pennil is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING' Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to cnminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attomey's fees JS^ CONTRACTOR SIGNATURE • AGENT DATE / hereby affinn that I am exempt from Contractor's License Law for the following reason I I I, as owner of the property or my employees with wages as their sole compensation, will do the wort( and the stnicture is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) I I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) I I I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and matenals for construction of the proposed property improvement QYes IK. [No C2!^li3ve / have not) signed an application for a building permit for the proposed work i 3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number) ^^^ljSO}0 Q-lzJlLll^t C- 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of wori() sTPTi PROPERTY OWNER SIGNATURE GENT DATE /3 Is the applicant or future building occupant required to submit a business plan, acutely hazardous matenals registration form or nsk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account AcP '(> ' Yes , No Is the applicant or future building occupant required to obtain a permit from the air pollution control distnct or air quality management distncP , Yes No Is the facility to be constnjcted within 1,000feetof the outer boundary of a school site'' ,Yes , ',No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name Lender's Address I certify that 1 have read the application and state that the above infbmnaton is conectand that the infonnaton on the plans is accurate. 1 agree to comply with all City ordinances and State laws relabng to building construction. I hereby authonze representative of the City of Carlsbad to enter upon the above mentioned property fbr inspecton purposes I ALSO AGREE TO SAVE, INDEMNII^ AND KEEP HAFiMLESS THE CITY OF CAFISBAD AGAINST Aa LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMFF OSHA An OSHA pemiit is required for excavatons over 5'0' deep and dennolition or constmction ot sfructures over 3 stones in heght EXPIFiATION Every pemiit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authonzed by such pemiit is not commenced within 180 days from the date of such perniit or if the building or work authonzed by such penrat is suspended or abandoned at any time after the vmrk is commenced for a penod of 180 days (Section 106 4 4 Unifonn Building Code) vfiS"APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY If a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email buildinq(S)carlsbadca gov or Mail the completed fonm to City of Carlsbad, Building Division 1635 Faraday Avenue, Cartsbad, California 92008 C0#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE STATE ZIP Carlsbad CA PHONE EMAIL OCCUPANT'S BUS LIC No DELIVERY OPTIONS PICK UP: CONTACT (Listed above) OCCUPANT (Listed above) ^.CONTRACTOR (On Pg 1) MAIL TO: CONTACT (Listed above) , CONTRACTOR (On Pg 1) IVIAIL / FAX TO OTHER: OCCUPANT (Listed above) ASSOCIATED CB#- NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION APPLICANT'S SIGNATURE DATE Inspection List Permit#: CB131861 Type: PME CITY HALL-REPLACE MAIN SWITCH GEAR Date Inspection Item Inspector Act Comments 02/18/2014 39 Final Electncal PD AP 02/14/2014 33 Service Change/Upgrade -Rl 02/14/2014 34 Rough Electric PD AP 02/13/2014 33 Service Change/Upgrade -Rl 02/13/2014 34 Rough Electnc PD NR Thursday, February 20, 2014 Page 1 of 1 EsGil Corporation In (PartnersHip witH Qovemment for (BuiCding Safety DATE: November 21, 2013 JURISDICTION: Carlsbad PLANCHECKNO.: 13-1861 SET: II PROJECT ADDRESS: 1200 Carlsbad Village Drive PROJECT NAME: City Hall New Electrical Service • ^AEELLQANT JURIS. 1?EVIEWER • FILE XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. • The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: IXI EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Bob Richardson Telephone #: 760 802-4559 Date contacted: (by: ) Email: bob.richardson@carlsbadca.gov Fax #: Mail Telephone Fax In Person • REMARKS: By: Eric Jensen EsGil Corporation • GA • EJ • PC Enclosures: 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (PartnersHip witH Qovemment for (BuiCding Safety DATE: August 15, 2013 •..APPtli^ANT p JURIS^ JURISDICTION: Carlsbad •"PCAN REVIEWER • FILE PLANCHECKNO.: 13-1861 SET I PROJECT ADDRESS: 1200 Carlsbad Village Drive PROJECT NAME. City Hall New Electrical Service I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. [ I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to. I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. IXI EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Bob Richardson (V-M-^ Telephone#: 760 802-4559 Date contacted: ^\4lo(by:|c- ) Email: bob.richardson(a)carlsbadca.gov Fax #: € Mail ^ Telephone ^ Fax In Person • REMARKS: By: Eric Jensen Enclosures: EsGil Corporation • GA • EJ • PC 08/08 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 13-1861 August 15, 2013 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PLANCHECKNO.: 13-1861 PROJECT ADDRESS: 1200 Carlsbad Village Drive DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL CORPORATION: 08/08 August 15, 2013 REVIEWED BY: Eric Jensen FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? • Yes • No Carlsbad 13-1861 August 15, 2013 ELECTRICAL and ENERGY COMIVIENTS PLAN REVIEWER: Eric Jensen ELECTRICAL (2010 CALIFORNIA ELECTRICAL CODE) 1. Distribution panel "MSE" appears extremely underpowered for its loads. Exacerbating the issue is the additional (2) panels on the single line not shown on the existing 225 ampere system? Please explain how this set-up (the 225 ampere supply and, additionally, the additional panels) will function. 2. The new ATS, three or four pole? Any changes to the grounding necessary? CEC 250.30 3. Include the specification for the Utility fault current available and the AlC rating for all service overcurrent devices. 4. Specify whether the system design is fully-rated, series rated, or engineered (fault current levels shown throughout the system). • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Eric Jensen at Esgil Corporation. Thank you. Carlsbad 13-1861 August 15, 2013 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLANCHECKNO.: 13-1861 PREPARED BY: Eric Jensen DATE: August 15, 2013 BUILDING ADDRESS: 1200 Carlsbad Village Drive BUILDING OCCUPANCY' TYPE OF CONSTRUCTION: BUILDING PORTION AREA (Sq Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review D Repetitive Fee ^ 1 Repeats Based on hourly rate • Complete Review • Other 0 Hourly EsGil Fee $215.00 • Structural Only $86 00 Hrs. $172.00 Comments 2 hours plan review Sheet 1 of 1 macvalue doc + MICHAEL WALL ENGINEERING RESPONSE Novembers, 2013 Eric Jensen EsGil Corporation 9320 Chesapeake Dnve, Suite 208 San Diego, CA 92123 Re City of Carlsbad - City Ha|l Main Electrical Room Evaluation & Replacement Plan Check Number: 13-1861 MWEJobNo 12-216 We have received the comments from your plan review for the above referenced project. We have responded to'each Issue {in italics), and have included the original Issues (in boldface) for your reference • 1. Distribution panel "MSE" appears extremely underpowered for its loads. Exacerbating the issue is the additional (2) panels on the single line not shown on the existing 225 ampere system? Please explain how this set-up (the 225 ampere supply and, additionally, the additional panels) will function. Response The peak demand load on the building service (per SDG&E) is 69kW The peak demand load that will be on panel MSE is 38kW (per a 30- day recording performed by the City of Carlsbad), which equates to 106 amps • 2. The new ATS, three or four poles? necessary? CEC 250.30. Any changes to the grounding SAN DIEGO 858-638-0600 858-638-0640 FAX 4115 Sorrento Valley Blvd San Diego, CA 92121 IRVINE 949-864-0600 949-864-0640 FAX Response The new ATS is 4-pole, which matches the demolished ATS No grounding revisions are required • 3. Include the specification for the Utility fault current available and the AlC rating for all service overcurrent devices. Response the utility AFC is 42kA, and the new switchgear is rated at 65kAIC • 4. Specify whether the system design is fully-rated, series rated, or engineered (fault current levels shown throughout the system). Response The new system shall be fully-rated We trust that these responses, along with the corrections to the plans, meet with your approval Should you have any questions or comments, please feel free to contact me at 858-638-0600 19600 Fairchild Road Suite 200 Irvine, CA 92612 www mwalleng com Sincerely, Guy Carpino Michael Wall Engineering NOV 1 3 2013 CITY OF CARLSBAD BUILDING DIVISION CB131S61 1200 CARLSBAD VIUAGEDR opF II/,3/1^ c^^^^'^^. ^^-^ uU^^lo tni-P-f7/^ ^ Final Inspection required by: • Plan • CM&I • Fire SW QlSSUED •CV Approved Date, By BUIU3ING 77 7 11^ PLANNING (If** ENGINEERING -— FIRE Expedite? Y N — AFS Checked by HazMat APCD Health Forms/Fees Sent Rec'd Due? By Encina Y N Fire Y N HazHealthAPCD Y N PE&M Y N School Y N Sewer Y N Stormwater Y N Special Inspection Y N CFD- Y N LandUse Density ImpArea FY Annex Factor PFF. Y N Comments Date Date Oate Date Building Planning Engineenng Fire Need? , r\ / \ f 7ifiip\,^-(- rn-^n-^^—ljU.f> * • Done a Done