Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1201 MAGNOLIA AVE; ; CB911119; Permit
12-03-2009 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Building Permit Permit No:CB911119 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: OccGroup: 1201 MAGNOLIA AV CHAD RADMAJ Sub Type : 2052800800 Lot #: $0.00 Const Type: Ml Reference #: VN Project Title: 1755 SF 2 GARAGES Status^ Applied: Entered By: Appr/Issued: Inspect Area: 08/05/1991 DC Applicant: HOPKINS, JOHN Owner: HOPKINS JOHN A&LINDA A 1201 MAGNOLIA AV CARLSBAD, CA 92008 619 434-0737 Total Fees: $0.00 $194.00 Payments To Date:$194.00 Balance Due: Description Other Fee 194.00 Inspector: FINAL APPROVAL Date: I7T3 I Clearance: NOTICE: Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION City of Carlsbad Building Department 2075 Las PaImas Dr., Carlsbad, CA 92009 (619) 438-1161 1. FbKMll ITfPfc A - U Commercial U New Building LJ Tenant Improvement B - D Industrial D New Building D Tenant Improvement C-/ifi Residential D Apartment DCondo D Single Family Dwelling >fcj Addition/Alteration D Duplex D Demolition D Relocation D Mobile Home D Electrical D Plumbing D Mechanical D Pool D Spa D Retaining Wall D Solar D Other 2. PROJECT INFORMATION PLAN CHECK NO. y/L^/^^ C-PRMT 194-00 FOR OFFICE USE ONLY uullam& OT sulle N0- Nearest Cross Street LEGAL DhSCRIPllON huDclivision jName/Numuer Phase No. CHECK BELOW Ir bUbmll IbU: d 2 Energy Calcs pt& Structural Calcs Bfe Soils Report D 1 Addressed Envelope ASSESSOR'S PARCEL EXISTING USE JROPOSEDJISE 4. APPLICANT tJCONTRACTOR CITY U AGENT FOR CONTRACTOR ADDRESS ZIP CODESTATE DAY TELEPHONE 5. PROPERTY OW CITY STATE ADDRESS ZIP CODE DAY TELEPHONE t>. coN'i«Ac:iutt NAME ^^LL13 CITY WtV^P^ STATE STATE LIC. # ADDRESS £f&\J ZIP CODE LICENSE CLASS DAY TELEPHONE CITY BUSINESS LIC. # UKMUNfcH NAME CITY W^f STATE ZIP CODE DAY TELEPHONE 7. WORKERS^ COMPENSATION STATEUC. # WorkerrCompensation Declaration: I hereby ailirm that I have a certificate ot consent to self-insure issued by the Director or Industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POLICY NO.EXPIRATION DATE Certificate ot Exemption: rcertify that in the performance ot the work tor which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE S. OWNER-BUILDER DECLARATION Owner-Builoer Declaration: I hereby affirm that I am exempt from the Contractors License Law tor the following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor^) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). SIGNATURE DATE — COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES n NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 9. UJNSTKULTniJN LENDING ACiKNUY I hereby attirm that there is a construction lending agency tor the performance ot the work tor which this permit is issued (Sec 30970) Civil Code). LENDER'S NAME LENDER'S ADDRESS 1OTAPPLTCANT CERTIFICATION I certify that f have read the application and state that the above intormation is correct. 1 agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SATO CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). APPLICANTS DATE: ? -5"'*? / :TE: File YELLOW: Applicant PINK: Finance City of Carlsbad Building Department DATE: 07/31/92 TO: HOPKINS, JOHN 1201 MAGNOLIA AVENUE CARLSBAD, CA 92008 PLAN CHECK EXPIRATION PC# CB911119 DATE: 08/04/92 ADDRESS: 1201 MAGNOLIA AV You have applied to have your plans checked on the date shown above, and you have not obtained your building permit. The provisions of Section 304(d) of the Uniform Building Code state: "Section 304(d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official. In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee." Please check the appropriate box indicating your choice and return this letter to the BUILDING DEPARTMENT.i PROJECT ABANDONED. I WILL PICK UP PLANS WITHIN 10 DAYS. PROJECT ABANDONED. PLANS MAY BE DESTROYED. If you have any questions, please contact the Building Department at (619) 438-1161. DORIS COSMAN Building Department 2O75 Las Palmas Drive Carlsbad, California 92OO9-1576 (619) 438-1 161 ESGIL CORPORATION 932O CHESAPEAKE DR., SUITE 2O8 SAN DIEGO, CA 92123 (619) 56O-1468 DATE: JURISDICTION: PLAN CHECK NO: PROJECT ADDRESS: PROJECT NAME: SET; ZZT I APPLICANT rukrsDicTioi LJPLAN CHECKER QFILE COPYFJUPS nDESIGNER The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified g>£t OUj are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. : The check list transmitted herewith is for your information. ^ The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. I; The applicant's copy of the check list is enclosed for the —' jurisdiction to return to the applicant contact person. jj The applicant's copy of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. "j Esgil staff did advise applicant that the plan check has "" been completed. Person contacted: Date contacted: REMARKS; Telephone f >TM T~»e A3 THAT S f 7t> Tt> By:Enclosures: ESGIL CORPORATION DGA DCM VST ..«/ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: JURISDICTION: PLAN CHECK NO CARLSBAD '-/M SET; IT PROJECT ADDRESS: PROJECT NAME: H APPLICANT jRISfrlCTICJI | jPLAN CHECKED COPY fDESIGNER D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction1s-building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until, corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: j^l Esgil staff did not advise the applicant contact person that plan check has been completed. ~~\ Esgil staff did advise applicant that the plan check has — been completed. Person contacted: Date contacted: REMARKS: Telephone # By: _ P ESGIL CORPORATION DGA DAA DRN QDM Enclosures FLAN CHECK MO:- /I/I FOREWORD? PT.EASE READ JURISDICTION: CITY OF CARLSBAD TO:6- ££ T 3r ENCLOSURES: PROJECT ADDRESS; /7-O/ A* A6 A/.3 L FLOOR AREA:. STORIES: HEIGHT: REMARKS: PLAN CORRECTION SHEET dn OF CARLSBAD SINGLE FAMILY AND DUPLEX DWELLINGS Date plans received by jurisdiction: Date plans received by Esgil Corporation: &A ft I Date initial plan check completed: I By: f E Applicant contact person: Telephone:. Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances by the Planning Department, Engineering Department or other departments. Present California law mandates that residential construction comply with Title 2^ and the following model codes: 1988 UBC (eff . 1/1/90) 1988 UPC (eff. 1/1/90) 1990 NEC (eff. 7/1/91) 1988 UMC (eff. 1/1/90) The above regulations construction, regardless adopted by ordinance. apply to residential of the code editions The circled items listed need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1988 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed i.e.. plan sheet, specification, etc. Be sure to enclose the marked up list when you submit the revised plans. NOTE: PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS WERE DELETED. List No. 12, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1988 UBC) / © PLANS Please nake all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, California 92123, (619) 560-1468. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction's building department. Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. Section 302(a)7. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Plans, specifications and calculations shall be signed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expiration date of license. (California Business and Professions Code). Specify on the Title Sheet of the plans the gross floor area of each element of this project including dwelling, garage, carport, patio, deck and balcony. Section 302(d). Provide a statement on the Title Sheet of the plans that this project shall conroljiLwith Title 24 and 1988 UBC, UMC and UPC and (1990) NEC. Submit fully dimensioned plot plan drawn to scale showing location, size, and use of all existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easeaents. Show location of all cut or fill slopes. Show finish floor elevations and show elevations of adjacent finish grade. Show drainage patterns with minimum slopes. Section 302(d). Indicate distance proposed building. pfZ-Ostzz T+t- cw from property Section 302(d). lines to -if A/I/0A/S © Show on the title sheet all structures, pools, walls, etc. included under this application. Any portion of the project shown on the site plan that is not included with the building permit application filed should be clearly identified as "not included." CAoSS vFO fJ-£6 A-<CP/A/-6- 7>f£ fjE<~> rfwS£_ S Clearly show if the lower level is a basenent or a story, based on the definitions in Sections 403 and 420. Plot the finish grade (as defined) on the elevations and dimension the distance to the floor above, for story determination. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below or sticky back. REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections., the following checked items will also require Special Inspection in accordance with Sec. 306 of the Uniform Building Code. ITEM REQ. IF CHECKED REMARKS SOILS COMPLIANCE PRIOR TO FOUNDATION INSP. STRUCTURAL CONCRETE OVER 2500 PSI PRESTRESSED STEEL FIELD WELDING HIGH STRENGTH BOLTS EXPANSION ANCHORS SPECIAL MASONRY SPRAYED ON FIRE PROOFING PILES/CAISSONS DESIGNER-SPECIFIED OTHER FIRE PROXELalOH Exterior walls closer than 3 feet to property lines shall be one-hour rated construction and have no openings. Table 5-A. 7/9/91 50 Provide spiral stairway details, per Section 3306 (f): a. Minimum run is 7 1/2 inches measured at a point 12 inches from where the treads are the narrowest. b. Maximum rise is 9 1/2 inches. Maximum clear opening between risers is 6 inches. c. Minimum headroom is 6 feet 8 inches d. The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail. Spiral stairways may not be used for required exits when the area served is greater than 400 sq. ft. Section 3306 (f). Provide I.C.B.O. Research Report and number for metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation. Exterior stairways shall not project into the 3 foot setback from the property lines. Section 3306 (n). The walls and soffits of the enclosed usable space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction. Section 3306 (m). 51. 52. 53. 54. 55. ¥• Within units, show that minimum width of 36 inches. ROOFIBG corridors have a Section 3305 (b). Specify roof slope. Roof slope is not adequate for roof type specified. Table 32-B,C,D and E. Specify roof material and application. Chapter 32. <-t6 HT- <->£.!& f+T Specify I.C.B.O. or U.L. approval number for roof materials not covered in U.B.C., e.g., tile, etc. Section 107. Specify minimum 1/4 inch per foot roof slope for drainage or design to support accumulated water. Section 3207 (a) and Section 2305 (f). Show roof drains and overflows. Section 3207. 6*. f f, JL. Provide skylight details to show compliance with Sections 3401 and 5207 or provide I.C.B.O. approval number. Plastic skylights must be separated from each other by at least 4 feet. Section 5207 (a) 6. Show attic ventilation. Minimum vent area is 1/150 of attic area or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents. Show required area and area provided. Section 3205 (c). MASONRY Provide fireplace construction details or note construction to be per attached fireplace standard drawing. Chapter 37. Show anchored veneer support and connections attached to wood in Seismic Zones 3 and 4, comply with Section 3006 (d)l and Section 2515 (a). Show ties and #9 wire in horizontal joints. Show height and construction details of all masonry walls. Chapter 24. Show floor and roof connections to masonry walls. Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater. Cross grain tension or bending in wood ledgers is not permitted. Section 2310. Show a minimum 2" air space and flashing between planter and building walls. Section 2516 (c) 7. GARAGE AMD CARPORTS Garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling. Table 5-B, Section 503 (d). All elements supporting floor above garage, including walls supporting floor joists, must have one-hour fire-resistive protection on the garage side. Section 503 (b) Show 1 3/8" solid core self-closing door for openings between garage and dwelling. Section 503 (d). Garages are not permitted to open into a room used for sleeping purposes. Section 1104. 12/18/90 f- /*• An occupancy separation is not required between carport and residence, provided the carport is open on two or more sides and has no enclosed uses above. Section 503 (a) Exception 3. Show garage framing sections, size of header over garage opening, lateral cross bracing at plate line, method bracing garage front and holddowns if required. Chapter 23. NOTE: Maximum shear panel height-to-width ratio is 3 1/2 to 1 for plywood. Table 25-1. Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold. Section 330^ (i). Provide an 18" raised platform for any FAU, water heater, or other device in the garage which may generate a flame or spark. UMC Section 508, UPC Section 1310 (a). FOUNDATION REOUIREHEKIS Per soils report, note on the plan the soils classification, whether or not the soil is expansive and note the allowable bearing value. Section 2905 (c). The foundation plan does not comply with the soils report recommendations for this project. Please review the report and modify design, notes and details as required to show compliance: _ Provide notes on the foundation plan listing the soils report recommendation for foundations, slab and building pad preparation. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (*fi?» required by the soil report). 82.) The soils engineer recommended that he/she review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: 1. The building pad was prepared in accordance with the soils report, 2. The utility trenches have been properly backfilled and compacted, and 3. The foundation excavations comply with the intent of the soils report". Show height of all foundation walls. 23. Show height of foundation walls. retained earth Chapter 23. Chapter on all ft.If cut or fill slopes exist, show distance of foundation to edge of cut or fill slopes and show steepness and heights of cuts and fills. Chapter 29. Note on plans that wood shall be 6" minimum above finish grade. Section 2907 (a). Note on plans that surface water will drain away from building and show drainage pattern and Uuy tlnMCTmu. Section 2905 (f). 88?) Dimension foundation per U.B.C. Table 29A: Floors Supported* 1 2 3 Footing Stemwall Width Depth Thickness 6" 8" 10" 12" 15" 18" 12" 18" 24" 6" 7" 8" ^Foundations may support a roof in addition to the floors. Where only a roof is supported, use foundation for one floor. Show foundation sills to be pressure treated, or equal. Section 2516 (c) 3. Show foundation bolt size and spacing. Section 2907 (f). Specify size, I.C.B.O. number and manufacturer of power driven pins. Show edge and end distances and spacing. Section 302 (d). •r.,6 2/13/90 If required, show size, embedment and location of hold down anchors on foundation plan.Section 302 (d). If hold downs are required, note on plan that hold down anchors oust be tied in place prior to foundation inspection. Section 305 (e) 1. Show adequate footings under all bearing walls and shear walls. Section 2907 (b). Show on the plans stepped footings for slopes steeper than 1:10. Section 2907 (c). Show minimum 18" clearance from grade to bottom of floor joists and minimum 12" clearance to bottom of girders. Section 2516 (c) 2. 977) Show pier size, spacing and depth into f" y. undisturbed soil. Table 29-A. Show minimum underfloor access Section 2516 (c). of 18" x 24". Show minimum underfloor ventilation equal to 1 sq. ft. for each 150 sq. ft. of underfloor area. Openings shall be as close to corners as practicable and shall provide cross ventilation on at least two approximately opposite sides. Section 2516 (c) 6. Show wall bracing. Every exterior wood stud wall and main cross-stud partition shall be braced at each end at least every 25 feet of length with 1x4 diagonal let-in braces or equivalent. Section 2517 (g) 3, Table 25-V. In 2-story buildings, shear panels at the first story (at least 48 inches in width) shall be located at each end or as near thereto as possible and comprise at least 25 percent of the linear length of the wall, or provide design. Section 2517(g)3, Table 25-V. Note cross bridging or blocking. Floor joists and rafters 12" or more in depth shall be supported laterally by bridging at intervals not exceeding 8 feet, unless both edges are held inline. Sec. 2506 (h), 2517 (d) 6. Show blocking at ends and at supports of floor joists, rafters and trusses at exterior walls. Section 2517 (d) 3, 2517 (h) 6. Bearing partitions, perpendicular to joists, shall not be offset from supporting girders, beams, walls or partitions, more than the depth of the joist. Section 2517 (d) 5. Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center and be just above the ceiling joists, where rafters and ceiling joists are not parallel. Section 2517 (h) 4. Show rafter purlin braces to be not less than 45 degrees to the horizontal. Section 2517 (h) 5. Show double top plate with nininun 48" lap splice. Section 2517 (g) 2. 108- Show nailing will be in conpliance with Table 25-Q. 106. 10§. / Show or note fire stops at the following locations per Section 2516 (f): a. In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10 foot intervals along the length of the wall; b. At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings; c. In concealed spaces between stair stringers at the top and bottom of the run and between studs along and inline with the run of stairs if the walls under the stairs axe unfinished; and d. In openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials. 110. In duplexes, draft stops shall be provided in floor-ceiling assemblies and attics in line with walls separating units and separating units from cocoon areas. Show stud size and spacing. Maximum allowable stud heights: Bearing wall: 2 x4 and 2x6 max. 10' max. 20' Non-bearing: 2 Table 25-R-3. x 4 max. 14' 2x6 Studs supporting two ceiling must be 3 x 4 Table 25-R-3. floors, a roof and or 2 x 6 at 16" o.c. Note on A.I.T.C. Certificate of Compliance for glued laminated wood members shall be given to the building inspector prior to installation. Section 2505. PC firTt.Pfi 7/6/91 fSa^Note on the plans that "all weather-exposed s / surfaces shall have a weather-resistive barrier to protect the interior wall covering and that exterior openings shall be flashed in such a manner as to make them weatherproof". Section 1707. KECHANICAL (UNIFORM MECHANICAL CODE) All heating, ventilating, and cooling systems and appliances shall comply with the Uniform Mechanical Code. 4- lj/0. 4 13 Show the size, location and type of all heating and cooling appliances or systems. Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70 degrees F. at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC, Sec. 1212. Note on the plans that the FAU closet or alcove must be 12 inches wider than the furnace or furnaces being installed. UMC Section 704. Show minimum 30" deep unobstructed working space in front of furnace. Section 505, UMC. Furnace shall not be installed in any bedroom, bathroom or in a. closet or confined space with access only through such room unless specified as direct vent appliance, enclosed furnace or electric heating appliance. Section 704 UMC. Show source of combustion Chapter 6, UMC. air to furnace, per l<te. Show access to the attic containing equipment to be minimum 30 inches by 30 inches. The opening may be 22 inches by 30 inches if the equipment can be removed through such opening. Section 708 UMC. Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 24 inches wide, not more than 20 feet in length through the attic. Section 708 UMC. Show permanent electrical outlet and lighting fixture controlled by a switch for furnace located in attic or underfloor space. Section 708 & 709 UMC. Show details to comply with Section 709 for furnace under the floor, or Section 710 for roof or outside furnace. i- I/O. A Show I.C.B.O. approval nuiaber for prefab fireplace. Show height of chinney above roof per I.C.B.O. approval or Table 37-B. Note on plan: Gas vents and non-combustible piping, in walls, passing through three floors or less shall be effectively draft stopped at each floor or ceiling. UBC, Section 1706 (a) 6. Provide dryer vent to outside. UMC, Section 1903. ELECTRICAL (NATIONAL ELECTRICAL CODE} All wiring shall comply with the National Electrical Code. Show on the plan the anperage of the electrical service, the location of the - service panel and the location of any sub- panels. If service is over 200 anps, submit single line diagram, panel schedule and load calculations. Note on the plans: "Electrical outlets shall be installed in accordance with NEC Article 210-52". Note on the plans: "Lighting outlets controlled by a wall switch shall be provided in accordance with NEC Article 210-70". 5. '6. Note on the plans: "Light in clothes closets will Article 410-8". fixtures installed conply with NEC Note convenience outlets in bathroons, kitchen counter top(s) within 6 feet of the kitchen sink, outdoors, and in garages and basements (other than for laundry and siailax equipment) shall be GFI protected. NEC, Art. 210-8. Note electrical system ground to be provided per NEC, Art. 250-80(a), 81(c). PLUMBDK? (UNTFORH PLUMBCTG CODE) Show water heater size, type and location on plans. UPC, Section 1301. Show source for providing combustion air to fuel burning water heater. If wall openings in an enclosure are used, at least one-half of the required opening area shall extend into the upper twelve inches of the enclosure and one-half within the lower twelve inches. UPC, Section 1307. 7/9/91 1^6 All new residential buildings, including additions, require a soils report. Please submit two copies. Exception: If a room addition is limited to one story and 1000 sq. ft. in area, then a soils report is not required. Esgil Corporation will advise the City to place their soils notice stamp on the plans. Heavy timber framing, minimum 6" x 10" beams and minimum 8" x 8" post, for the structural beam and column supporting the fire separation between the garage and living area above, is acceptable if shown on the plans. (city policy). All structures require a Class B roof covering, except room additions. If a room addition covers all of the existing building (2nd story addition), then the above exception doesn't apply. City Ordinance 9792 requires two parking spaces/unit with clear area of 20'x20' i.e. no washing machines, etc. Show compliance. All chimneys attached to any appliance or fireplace that burns solid fuel shall be equipped with an approved spark arrester. The net free area of the spark arrester shall be not less than four times the net free ara of the outlet of the chimney. The spark arrester screen shall have heat and corrosion resistance equivalent to 12 gauge wire, 19 gauge galvanized wire or 24 gauge stainless steel. Openings shall not permit the passage of spheres having a diameter larger than 1/2-inch and shall not block the passage of spheres having a diameter of less than 3/8-inch. mSCELLAKEOUS Please see additional corrections, on the following page. or remarks, To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. The City of Carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact \ p C H at Esgil Corporation. If you have any questions regarding City Building permit procedures, please contact Carter Darnell at the City of Carlsbad, 2075 Las Palmas Dr., telephone 619/438-1161. Thank you. Enclosures: Yes No 7/10/91 11 C*. <? /e (m) IE F-'LL f ,; - /A/ _ O</£(r AX. - . CT ) L L z~ pi. if' 715)5 0 u-f Aft * I Datet Prepared byt r F PLAN CHECK NO. Jurisdiction CARLSBAD VALUATION AND PLAN CHECK FEE -tin Q Bldg. Dept, Q Esgil BUILDING ADDRESS __ APPLICANT/CONTACT . BUILDING OCCUPANCY PHONE NO. DESIGNER PHONE TYPE OF CONSTRUCTION CONTRACTOR PHONE BUILDING PORTION £M- * Air Conditioning Commercial Residential Res. or Comm. Fire Surinklers Total Value BUILDING AREA /7S-S- — VALUATION •1ULTIPLIER (d °° "e @ § • • VALUE 3/S-fo 3/ s-^o Building Permit Fee $_ Plan Check Fee $ COMMENTS: ^'77 SHEET / OF I 12/87 » &BUILDING PLANCHECK V ;•' $1 s T C H E K — - _. 1" N D C H E K cs)<f DATE: An%*j.«tJaAClAnV t**]AW>cUUJ.0 4 ft- * t • PLANCHECK NO. CR °( 1 - 11 1 °[ * cu 3 R D C H E K C \ O 1 VI £•'-• ? "iO\ • SS 6-oTiS.aC. A^(^i4i"on PROJECT ID: / LEGAL Site REQUIREMENTS Plan ITEM COMPLETE ITEM INCOMPLETE NEEDS YOUR ACTION ITEM SELECTED EST, VA(_ - 31 n 1. Provide a fully dimensioned site plan drawn to scale. Show: north arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimension setbacks. 2. Show on site plan: Finish floor elevations, pad elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes, driveway with percent (%) grade and drainage patterns. 3. Provide legal description and Assessors Parcel Number. Discretionary Approval Compliance 4. No Discretionary approvals were required. 5. 6. Project complies with all Engineering Conditions of Approval for Project No. . Project does not comply with the following Engineering Conditions of Approval for Project No. Conditions complied with by:. Field Review Date: 7. 8. Field review completed. No issues raised. Field review completed. The following issues or discrepancies with the site plan were found: A. Site lacks adequate public improvementsnnn B. nnn Existing drainage improvements not shown or in conflict with site plan. C. Site is served by overhead power lines. P:\DOCS\MISFORMS\FRM0010.DH REV. 02/27/91 '—' '—' '—' D. Grading is required to access site, create pad or provide for ultimate street improvement. '—' '—' '—' E. Site access visibility problems exist. Provide onsite turnaround or engineered solution to problem. nnn F. Other: Dedication Requirements '—' '—' '—' 9. No dedication required. '—' '—' '—' 10. Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8V x 11" plat map and submit with a title report and the required processing fee. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. The description of the dedication is as follows: Dedication completed, Date By:. Improvement Requirements nnn 11. No public improvements required. SPECIAL NOTE; Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City inspector prior to occupancy. '—''—''—'12. Public improvements required. This project requires construction of public improvements pursuant to Section 18.40 of the City Code. Please have a registered Civil Engineer prepare appropriate improvement plans and submit for separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. The required improvements are: Improvement plans signed, Date: by:. P:\DOCS\MISFORMS\FRM0010.DH REV. 02/27/91 ' '—' '—' '—' 13. Improvements are required. Construction of the public improvements may be deferred in accordance with Section 18.40 of the City Code. Please submit a letter requesting deferral of the required improvements together with a recent title report on the property and the appropriate processing fee so we may prepare the necessary Future Improvement Agreement. The Future Improvement Agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future Improvement Agreement completed, Date: By: '—' '—' '—' 13a. Inadequate information available on site plan to make a determination on grading requirements. Please provide more detailed proposed and existing elevations and contours. Include accurate estimates of the grading quantities (cut, fill, import, export). I—I I—I 14 f No grading required as determined by the information provided on the site plan. '—' '—' '—' 15. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted for separate plan check and approval through the Engineering Department. NOTE; The Grading Permit roust be issued and grading substantially complete and found acceptable to the City Inspector prior to issuance of Building Permits. Grading Inspector sign off. Date: by: Miscellaneous Permits 16. Right-of-Way Permit not required. 17. Right-of-Way Permit required. A separate Right-of-Way Permit issued by the Engineering Department is required for the following: 18. Sewer Permit is not required. '—' '—' '—' 19. Sewer Permit is required. A sewer Permit is required concurrent with Building Permit issuance. The fee required is noted below in the fees section. DD 20. Industrial Waste Permit is not required. P:\DOCS\MISFORMS\FRM0010.DH REV. 02/27/91 '—' '—' '—' 21. Industrial Waste Permit is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Building Permits. Permits must be issued prior to occupancy. i Industrial Waster Permit accepted - Date: By: Fees Required 0 27. Park-in-Lieu Fee Quadrant: Fee per Unit: Total Fees: 23. Traffic Impact Fee Fee Per Unit: Total Fee: 24. Bridge and Thorough fare Fee Fee Per Unit: Total Fee: 0 25. Public Facilities Fee required. Qf 26. Facilities Management Fee Zone: Fee:. Qf 27. Sewer Fees Permit No. EDU's Benefit Area: Fee: Q 28. Sewer Lateral Required: Fee: D 29. REMARKS: ENGINEERING AUTHORIZATION TO ISSUE PERMIT BY: c ^<g6Ws» I MUfftsfifriLA* DATE: P:\DOCS\MISFORHS\FRM0010.0H REV. 02/27/91 PLANNING CHECKLIST Plan Check No. 7/-/J/7 Address Planner Phone 4384 161 ext. 4? (Name) APN: Type of Project and Use Zone *>H Facilities Management Zone ]_ Legend D Item Complete Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck number where deficiency was identified Environmental Review Required: YES DATE OF COMPLETION: NO TYPE Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval D Discretionary Action Required: YES _ NO (-xTYPE APPROVAL/RESO. NO. PROJECT NO. DATE: OTHER RELATED CASES: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval California Coastal Commission Permit Required: YES ^ DATE OF APPROVAL: San Diego Coast District, 3111 Camino Del Rio South, Suite 200, San Diego, CA. 92108-1725 (619) 521-8036 Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Landscape Plan Required: YES NO See attached submittal requirements for landscape plans Site Plan: -^\.. n a Zoning: oi£a 1. 2. 3. 4. 1. Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures. streets, existing street improvements, right-of-way width and dimensioned setbacks. Finish floor elevations ing, existing topographical "and driveway. Provide legal description of property. Provide assessor's parcel number. Setbacks: a i Front: Int. ^ide: Street Side: Rear: 2. Lot coverage: 3. Height: 4. Parking: Guest dditionai Comments /^^-^«"^C /° AjL$£f^ Ntiii <Ji-H,is:L' 5 M V*" ^C #{3 r u — rt- ii. ' l~ i ft ^" > ^ L,^ Required Required Required Required Required Required Spaces Required 2 Spaces Required f v-vf-p Atig_ -f- 5"V ' it I* fl-f" -^ — A /• ,i E AND ENTERED APPROVAL [NTO COMPUTER «^ Shown ^^ ./ l& Shown 3^/" jj(p Shown /M^ 2&f Shown 7r/f/< yu/* Shown ^ vu^ "2f Shown /« ~, f^Shown Z ,- *^ ^ " Shown ^ j^ ( i^-' , -« -y- ^i ' i i j- if A f ,.j_ ^ DATE PLNCK.FRM