Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1204 OAK AVE; ; PCR09092; Permit
12-16-2009 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No:PCR09092 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: PC#: Project Title: 1204 OAK AVCBAD PCR 1561805000 Lot#: 0 $0.00 Construction Type: 5B BUSBY: ADD 540SF DECK TO HOME Status: ISSUED Applied: 07/14/2009 Entered By: JMA Plan Approved: 07/22/2009 Issued: 07/22/2009 Inspect Area: Applicant: CHARLIE WILSON 760-580-6616 Owner: BUSBY GENE 1212OAKAVE CARLSBAD CA 92008 Plan Check Revision Fee Additional Fees $0.00 $0.00 Total Fees:$0.00 Total Payments To Date:$0.00 Balance Due:$0.00 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. City of Carlsbad Plan Check Revision No. Project Address Building Department Original Plan Check Na.C&O^l O'll-'Z— /2o £ QXk: /4</£ Date _ Q Name of Business at Project Address Contact ^ArJ.c D fLfc^ Ph' - - 74 1 Contact Address T>/ cTa/tf7 cityQtf 64*5/0* Z\p General Scope of Work Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 Elements revised: Calculations Soils Energy Q Other. Describe revisions in detail List page(s) where each revision is shown 4 List revised sheets that replace existing sheets 5Q f=r X 5 Does this revision, in any way, alter the exterior of the project? O Does this revision add ANY new floor area(s)? | | Yes T Does this revision affect any fire related issues? Q Yes Is this a complete set? [ | Yes @-f^b No 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: 760-602-2717/2718/2719 Fax: 760-602-8558 To: City of Carlsbad BUILDING DEPARTMENT ±635 Faraday Avenue, Carlsbad, CA 92008 Phone: 760-602-7541 / Fax: 760-602-8558 Plan Check Comments / 2OO7 Codes From: Steve Borossay Fax:-7 7 Pages: Phone:Date: Address: CONTACT HOURS FOR STEVE BOROSSAY: TUESDAY THROUGH FRIDAY; 1PM - 5PM V Please make corrections referred to below and run TWO new prints. If red marks are on plans as a part of this Plan Check response please return red marked set with the new prints. »»» This is a BUILDING REVIEW ONLY. Comments or approval do not apply to any other City department review. For information on the status of approval from other departments please contact staff ©760-602-2717 / 2718 / 2719. 3 o \s> ta ex. A-r PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB O 9~ ADDRESS DATE 7 RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR (<$17,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER DATE DATE Docs/Misforms/Planning Engineering Approvals Mr 0 n n D n PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. PCR 09-92 Address 1204 Oak Avenue Planner GINA RUIZ Phone (760) 602- 4675 APN: 156-180-50-00 Type of Project & Use: ADDITION OF DECK Net Project Density: 1.0 DU/AC Zoning: R-1 General Plan: RM Facilities Management Zone: 1 CFD (in/out) #_Date of participation: Remaining net dev acres: Circle One (For non-residential development: Type of land used created by this permit: Legend: [>3 Item Complete Environmental Review DATE OF COMPLETION: Item Incomplete - Needs your action YES D NO IEI TYPE Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: APPROVAL/RESO. NO. DATE . PROJECT NO. OTHER RELATED CASES: YES D NO IE! TYPE Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES d NO M CA Coastal Commission Authority? YES D NO El If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Habitat Management Plan Data Entry Completed? YES D NO D If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) Inclusionary Housing Fee required: YES D NO [X] (PER CB090722) (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES [X] NO D (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08 Site Plan: man IEI D a Policy 44 - Neighborhood Architectural Design Guidelines 1. Applicability: YES D NO [X] 2. Project complies: YES Q NCQ Zoning: 1. Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: Required 20; Shown 20' Required 9J. Shown 9^ Required N/A Shown N/A Required!^ Shown 18' Required N/A Shown N/A 2. Accessory structure setbacks: Front: Interior Side: Street Side: Rear: Structure separation: Required Required Required Required Required Shown Shown Shown Shown Shown 3. Lot Coverage:Required LESS THAN 40% Shown OLD COVERAGE IS SHOWN Shown NOT SHOWN4. Height: Required 24' MAX 5. Parking: Spaces Required 2 Shown 4 (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments #1. Update total lot coverage and include deck into calculations. The total shown on sheet SP.1 is from CB090722. #2. Show the total height of the deck. -1DATE IOK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08 PCR09092 1204 OAKAV BUSBY: ADD 540SF DECK TO HOME - To /