10-12~2016 Pool Permit Permit No: CB163629
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
1222 ESMAT WY CBAD
POOL
Lot#: 0
Valuation:
1563512000
$19,077.00 Construction Type: NEW
Reference #:
PC#:
Project Title: GRIFFITHS: 370 SF POOL I SPA
Applicant:
MAJESTIC POOLS & SPAS
STE 114
7905 SILVERTON AVE
SAN DIEGO CA 920126-634
858 790-9921
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Electrical Fee
Plumbing Fee
Strong Motion Fee
Green Bldg Standards (SB1473) Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Additional Fees
TOTAL PERMIT FEES
Owner:
Total Fees: $419.07 Total Payments To Date:
Inspector:
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
ISSUED
09/22/2016
SLE
10/12/2016
10/12/2016
$203.29
$0.00
$142.30
$0.00
$35.00
$35.00
$2.48
$1.00
$0.00
$0.00
$0.00
$0.00
$419.07
$419.07 Balance Due:
Clearance:
$0.00
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter rollectively
referred to as ''fees/exactions." You have 90 days from the date this permit was issued to protest i~ition of these fees/exactions. If you protest them, you must
follavv the protest procedures set forth in Gc:Nemment Code Section 660ZO:,a), and file the protest and any other required information with the City Manager for
processing in acrordance 'Mf.h Carlsbad rv'unidpal Ccx:le Section 3.32.030. Failure to timely follcm that procedure Vvill bar any subsequent tegal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and seNer oonnection fees and capacity
changes, nor planning, zoning, grading or other sirrilar application processing or service fees in connection with this project. NOR OOES IT APPLY to any
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
10-12-2016
Storm Water Pollution Prevention Plan (SWPPP) Permit
Permit No:SW160465
Job Address:
Permit Type:
Parcel No:
Reference #:
CB#:
Project Title:
Applicant:
1222 ESMAT WY CBAD
SW PPP
1563512000
CB163629
GRIFFITHS: POOL/ SPA
MAJESTIC POOLS & SPAS
STE 114
7905 SILVERTON AVE
SAN DIEGO CA 920126-634
858 790-9921
Emergency Contact:
ROB ROMERO
858-860-6109
SWPPP Plan Check
SWPPP Inspections
Additional Fees
TOTAL PERMIT FEES
Status:
Lot#: 0 Applied:
Entered By:
Issued:
Inspect Area:
Owner:
MIKE & TANYA GRIFFITHS
1222 ESMAT WY
CARLSBAD CA 92008
760-672-1920
Tier:
Priority:
ISSUED
09/22/2016
SLE
10/12/2016
1
M
$54.00
$228.00
$0.00
$282.00
Total Fees: $282.00 Total Payments To Date: $282.00 Balance Due: $0.00
FINAL APPROVAL
DATEl)4,bi./11 CLEARANCE ____ _
SIGNATURE f'v'\· ~,tu,,i,
-
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: Q PLANNING D ENGINEERING 0 BUILD1NG O FIRE 0 HEALTH D HAZMAT/APCD
( Cicyof Building Permit Application Plan Check No. () (O \ l () .,~ O ~
1635 Faraday Ave., Carlsbad, CA 92008 Est. Value \q t~'l' \
Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit -, Carlsbad email: building@carlsbadca.gov
www.carlsbadca.gov Date ~-?? _... It o lswPPP ll o -4.n 5
JOB ADDRESS SUITEf/SPACEf/UNITf
IAPN IS {p ~D 1222 Esmat Way, Carlsbad, CA 92008 -3Si --6D
CT/PROJECT 11 r OTII I PHASE II I II OF UNllS t BEDm,vMS 11 BATHROOMS I TENANT DU;>fNESS NAME I CONSTR. TYPE I occ. GROUP
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
Install new in-ground swimming pool & spa (370 sqft)
EXISTING USE I PROPOSED USE I GARAGE (SF) PATIOS (SF) I DECKS (SF) FIREPLACE I AIR CONDITIONING I FIRE SPRINKLERS
Single Family Residence YES0, NcQ YES 0 No0 YEsO NOD
APPLICANT NAME Rob Romero PROPERTY OWNER NAME Mike & Tanya Griffiths D-•-I'••+• ...
ADDRESS ADDRESS
9903 Businesspark Avenue, #103 1222 Esmat Wav
CITY STATE ZIP CITY STATE ZIP San Dieao CA 92131 Carlsbad CA 92008
PHONE 'FAX PHONE rAX 858-790-9919 760-672-1920
EMAIL EMAIL
rob@majesticpools.net mike.griffiths@adtinc.net
DESIGN PROFESSIONAL CONTRACTOR BUS. NAME Majestic Pools & Spas
ADDRESS ADDRESS 9903 Businesspark Avenue, #103
CITY STATE ZIP CITY STATE ZIP
San Dieao CA 92131
PHONE IFAX PHONE IFAX 858-790-9919
EMAIL EMAIL
heatherv@majesticpools.net
'STATE UC.# STATELIC.# lei.ASS I cm BUS. uc.1235662 973388 C-53
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct. alter. improve. demolish or repair any structure. prior torts issuance, also requires the
applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law /Chapter 9, commending with Secbon 7000 of Division 3 or the Business and Professions Code} or that he is exem_pt therefrom. and the basis for the alleged exemption. Any violatJon of See1Jon 1031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than ftve hundred dollars [$500}).
Wortlen' Compensation Declaration: I hereby aff'rrn under penalty of perjury one of the following c/eclaraoons: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Secoon 3700 or the Labor Code, for the perfommce of the work for which this permit is issued.
[Z] I have and will maintain wor1ters' compensation, as required by Section 3700 of the Labor Code, for the perfofmalce of the work for which this permit is issued. My wcrters' compensation insurance carrier and policy
number are: Insurance Co. American Zurich Policy No. WC009391801 Expiration Date 04/01117
This section need not be completed~ the permit is for one hundred doUars ($100) or less. 0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shail not employ any person in any manner so as to become subject to the Wcrters· Compensation Laws of
Galifornia. WARNING: Failure to secure wortlers' compensation coverage is unlawful, and shall subject an employer to cr1minal penalties and civil fines up to one hundred thousand dollars (&100,000), In
addlUon to the cost of compensation, damag s as provld for in ~on .1,706 of the labor code, Interest and attorney's lees.
25 CONTRACTOR SIGNATURE \l ~ [Z)AGENT DATE q
I hereby aff',m that I am exempt from Cootrador's Lirense Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not inleoded or offered for sale (Sec. 7044, Business and Professions Code: The Cootractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder wil have the burden of proving lhat he did not build or improve for the purpose of sale).
D
D
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I am exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construe lion of the proposed property improvement. O v es O o
2. I (have I have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordina1e, supervise and provide the major work (include name I address I phone I contractors' license number):
5. I will provide some of the work. bul I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work):
25 PROPERTY OWNER SIGNATURE 0AGENT DATE
....
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazal'dous Substance Account Act? D Yes D No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D Yes D No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D Yes D No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I certify that I have read the application and state that the above lnfonnatlon is correct and that the infonnation on the plans Is accurate. I agree to comply with all City ordinances and State laws relating to build Ing construction.
I hereby authorize represenlative of the City of Carlsbad to enter upon the above mentioned properfy for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA perm~ is required for excavations aver 5'0' deep and demolition or construction of strucb.Jres over 3 stories in height
EXPIRATION: Every permit issued by the Bu ing Official under the provisions of this Code shall expire by limilation and become null and void if the building or wor1< authorized by such permit is not coovnenced within
180 days from the date of such permit or if the uild orwor1< authorized b such perm~ is suspended or abandoned at anytime after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code).
~ APPLICANT'S SIGNATURE DATE
BLDG-Residential
Pool
Application Date: 09/22/2016 Owner:
Work CI.Jss: lssun Dato· 10/12/2016 Suhdiv1sion:
Sta1u::;. Closed -Finaled Expiration Date: 08/23/2017 Address:
Scheduled
Date
Actual
Start Date
12/08/2016 12/08/2016
02/24/2017 02/24/2017
03/07/2017 03/07/2017
04/06/2017 04/06/2017
April 06, 2017
IVR Number: 717294
Inspection Type Inspection No.
BLDG-51
Excav/Steel/Bondlng
/Fence(Pools)
004677 -2016
NOTES Created By
Michael Collins
BLDG-55
Fence/Preplaster
014595-2017
BLDG-Final
Inspection
BLDG-Final
Inspection
Checklist Item
BLDG-Building Deficiency
015660-2017
Checklist !tern
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
019082-2017
Checklist Item
BLOG-Plumbing Final
BLDG-Building Deficiency
BLDG-Electrical Final
BLDG-Building Deficiency
BLOG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Inspection Status Primary Inspector
Passed Michael Collins
TEXT
Equipotential bond.
Passed Paul York
COMMENTS
Failed Michael Collins
COMMENTS
Notice
Passed Michael Collins
COMMENTS
Gfi protection ok.
Notice
1222 Esmat Wy
Carlsbad, CA
Re inspection Complete
Complete
Created Onto
12/08/2016
Passed
No
Reinspection
Passed
No
No
No
No
No
Passed
Yes
Yes
Yes
No
No
No
No
No
Complete
Complete
Complete
Page 1 of 1
Inspection History:
10/31/2016: 23-BLDG-Gas/Test/Repairs Approval Completed By MC METER TO EQUIP. PAD;
10/31/2016: 51-BLDG-Excav/Steel/Bonding/Fence Approval Completed By MC;
10/31/2016: 52-BLDG-Underground Plumbing Approval Completed By MC;
10/31/2016: 53-BLDG-Electric/Conduit/Wiring Approval Completed By MC METER, EQUIP. PAD, LIGHT
SHELLS, DECK & STEEL BONDING.
,,~
«1~ ~ CITY OF
CARLSBA[D I I
PLAN CHECK
REVIEW
TRANSMITTAL
DATE: 10/11/2016 PROJECT NAME: Griffiths Family Pool and spa
PLAN CHECK NO:CB16362 ~ SET#: 1 ADDRESS: 1222 EsmatWay
VALUATION/SCOPE OF WORK: 19077
Community & Economic
Development Department
1635 Faraday Avenue
Carlsbad CA 92008
www.carlsbadca.gov
PROJECT ID:
APN: 1563512000
This plan cheqk review is complete and has been APPROVED by the ENGINEERING
Division. I
I
By: ValRay Nelson!
A Final lnspec~ion by the.Engineering Division is required Yes I No
This plan che~lk review is NOT COMPLETE. Items missing or incorrect are listed on the
attached che klist. Please resubmit amended plans as required.
NOTE: ONLY I EMS THAT NEED CORRECTION/CLARIFICATION ARE MARKED X.
Plan Check c1mments have been sent to: rob@majes~icpools.net
You may also have c r>rrectlons from one or more of the divisions listed below. Approva I
from these divisions may be required prior to the Issuance of a building permit.
Resubmitted plans s rrould Include corrections from all divisions.
For questions or clarificat ons on the attached checklist please contact the following reviewer as marked:
PLANNING ENGINEERING ~ FIRE PREVENTION
760-602-4610 76(),602-2750 76(),602-4665
Chris Sexton I Kathleen Lawrence Greg Ryan
760-602-4624 760-602-27 41 760-602-4663
Chris.SextQn~cs;!rls!2s;!!:!Cs;!.g2v Ks;!thl~~n.Ls;!wr~ni;;~~carls!2s;!!:!Cs;!,gQv Gr~goiy.Ryan~carlS!2s;!i;!i;;s;!.gQv
Gina Ruiz I Linda Ontiveros Cindy Wong I 760-602-4675 760-602-2773 760-602-4662
Gina.Ruiz@carlsbad""'.om Linda.Qnti~ecQs\\l!i;;arls!:!adca.gov Cyatbia,WQaf!@cl:!tls!:!a!:!ca.gQv
./ ValRay Marshall Dominic Fieri
760-602-2741 760-602-4664
I ValRay.Marsha ll@carl sbadca .gov 0Qminii;;.Fi~ri~i;;arl:i!2adca.gov
'
Remarks:
CB163
Any outstanding issues will be 1narked lvith an [X] Make then cessary corrections for
compliance 1.vith applicable codes and standards. Subinit corrected plan-and/or specifications to
the Building division for re-sub1nittal to the Engineering flivisions .
. Itenis that conform to pennit require1nents an' ntarke1f 1.vith [{]
1. SITE PLAN
plot all easements Provide a fully dimensioned site plan drawn to scale.
and dimensions Show:
E-37
-------------· -
North arrow
Existing & proposed structures
Property line dimensions
Easements
Show on site plan:
Drainage patterns
Existing & proposed slopes
Existing topography
Retaining Walls (location and height)
Indicate what will happen with soil excavated from pool area.
Include on title sheet:
Site address
Assessor's parcel number
Legal description/lot number
Grading: Quantities of
Cut . Fill Import ExportC:]
Project does not comply with the following engineering conditi~ns of approval
for project no: ·
Conditions were complies with by: Date:
LOT NO. par 1
MAP NO. 21225
REF. NO. CT 11-02 Schei MS
Page 2 of4 REV6/2012
•
.. CB163629
RW 16-227
E-37
1
2. GRADING PERMIT REQUIREMENTS
The cqnditions that require a grading permit are found in Section 11.06.030 of the Municipal
Code.!
Inadequate information available on site plan to make a determination on grading
rdquirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and
rejmedial). This information must be included on the plans. If no grading is proposed
~rite: "NO GRADING"
i
Grading Permit required. NOTE: The grading permit must be issued and rough grading
approval obtained prior to issuance of a building permit. A separate grading plan prepared a
registered civil engineer must be submitted together with the completed application form attached.
·1 ~o grading permit required.
i
' 3. MIS£ELLANEOUS PERMITS
I
~IGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work
a~jacent to the public right-of-way.
i
A separate right-of-way issued by the engineering division is required for the following:
i
P[lease complete attached right-of-way application form and return to the engineering
diapartment together with the requirements on the attached right-of-way checklist, at
t1e time of resubmittal.
R/ght-of-way permit and pool permit will be issued simultaneously.
Page 3 of4 REV 6/2012
CB163629
E-37
•
1
4. STORM WATER
Construction Compliance
Project Threat Assessment Form complete[ incomp ete
Requires Tier 1 Storm Water Pollution Prevention Plan. lease complete attached form
and·return (SW 1•-)
1
Requires Tier 2 Storm Water Pollution Prevention Plan. I Requires submittal of Tier 2
SWPPP, payment of processing fee and review by city.
i
I
Post-Development (SUSMPl Compliance
Storm Water Standards Questionnaire complete in~omplete
I
Project is subject to Standard Storm Water Requirements. I See city Standard Urban
Storm Water Management Plan (SUSMP) for referen e.
ht! ://www.carlsbadca. ov/business/buildin /Documents/E Standsw-stds-vol4-ch2. di
Project needs to incorporate low impact development s rategies throughout in one or
more of the following ways:
Rainwater harvesting (rain barrels or cistern)
Vegetated Roof
Bio-retentions cell/rain garden
Pervious pavemenUpavers
Flow-through planter/vegetated or rock drip line
Vegetated swales or rock infiltration swales
I Downspouts disconnect and discharge over landscape
Qlb.er;
5. ADDITIONAL COMMENTS
Page 4 of4 REV 6/2012
"4. «~~ i ~ CITY OF
CARLSBAD>
'
PLAN CHECK
REVIEW
TRAN SM ITT AL
DATE: 10/03/2016 PROJEd T NAME: Griffiths Family Pool and spa
Community & Economic
Development Department
1635 Faraday Avenue
Carlsbad CA 92008
www.carlsbadca.gov
PROJECT ID:
PLAN CHECK NO: CB163629 SET#: 1 ADDRESS: 1222 Esmat Way APN: 1563512000
VALUATION/SCOPE OF WbRK: 19077
This plan cheqk review is complete and has been APPROVED by the ENGINEERING
Division.
By: ValRay Nelson
I
A Final Inspection by the Engineering Division is required Yes ./ No
X This plan che9k review is NOT COMPLETE. Items missing or incorrect are listed on the
attached cheej:klist. Please resubmit amended plans as required.
NOTE: ONLY ITiEMS THAT NEED CORRECTION/CLARIFICATION ARE MARKED X.
Plan Check Comments have been sent to: rob@maJesticpools.net
I
You may also have cprrectlons from one or more of the divisions listed below. Approval
from these divisions (may be required prior to the Issuance of a building permit.
Resubmitted plans s ould Include corrections from all divisions.
For questions or clarificat ons on the attached checklist please contact the following reviewer as marked:
PLANNING ENGINEERING '\· FIRE PREVENTION
760-602-4610 760602-2750 760-602-4665
Chris Sexton Kathleen Lawrence Greg Ryan
760-602-4624 760-602-27 41 760-602-4663
Chri~.SextQn~!,i;!rl~bl;!d!.l;!.gQv Ki;!thle~o.Ll;!wr~m:.~~!.i;!rl~bl;!d!.l;!.gQ~ Gr~gQ!Y,8)'.l;!n@cl;!r!~bl;!d!.l;!.gQv
Gina Ruiz I Linda Ontiveros Cindy Wong
760-602-4675 760-602-2773 ', 760-602-4662
Gina .R uiz®r.::i rlsh::irlr.::i .11nJ Liada.Qativern5~!.arl5batl~a.gQv ~)'.nthia. WQng@carlsbadca.gQv
I
I ./ ValRay Marshall Dominic Fieri
760-602-2741 760-602-4664 I Va lRay.Marshall@carlsbadca.gov QQmini!,,fi~ri~!.i;![l~bi'!d!,i;!,gQv
Remarks:
Any outstanding issues will be 1narked 1vith an [X] Make the tu;.cessary corrections for
co111pliance 1vitli applicable codes and standards. Subn1it corrected plant, and/or specifications to
the Building divisiou for re-submittal to the Engineering divisions.
lte111s that confortn to pertnit require1nents are 1narkeii 1.vith [ZJ
1. SITE PLAN
plot all easements Provide a fully dimensioned site plan drawn to scale.
and dimensions Show:
E-37
North arrow
Existing & proposed structures
Property line dimensions
Easements
Show on site plan:
Drainage patterns
Existing & proposed slopes
Existing topography
Retaining Walls (location and height)
Indicate what will happen with soil excavated from pool area.
lnc1uae on title sheet:
Site address
Assessor's parcel number
Legal description/lot number
Grading: Quantities of
Cut Fill Import Export\·:
Project does not comply with the following engineering conditi(?ns of approval
for project no:
Conditions were complies with by: Date:
LOT NO. par 1
MAP NO. 21225
REF. NO. CT 11-02 Schei MS
Page 2 of4 REVG/2012
.CB163629 1
2. GRADl~G PERMIT REQUIREMENTS
The cdnditions that require a grading permit are found in Section 11.06.030 of the Municipal
Code. j
!~adequate information available on site plan to make a determination on grading
reiquirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and
rEjmedial). This information must be included on the plans. If no grading is proposed
~rite: "NO GRADING"
I
'
Grading Permit required. NOTE: The grading permit must be issued and rough grading
a roval obtained rior to issuance of a buildin ermit. A separate grading plan prepared a
re istered civil engineer must be submitted together with the completed application form attached.
I
~o grading permit required.
I
I
'
3. MIS ELLANEOUS PERMITS
RW 16-227 IGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work
E-37
a jacent to the public right-of-way.
1 separate right-of-way issued by the engineering division is required for the following:
I I
~lease complete attached right-of-way application fo. rm and return to the engineering
dbpartment together with the requirements on the attached right-of-way checklist, at
tie time of resubmittal. ·
I
~ight-of-way permit and pool permit will be issued simultaneously.
Page3of4 REV 6/2012
CB163629
E-37
1
4. STORMWATER I
Construction Compliance ,
I I
, Project Threat Assessment Form complete[=! incomplete,
Requires Tier 1 Storm Water Pollution Prevention Plan. ~lease complete attached form
and. return (SW 1•-)
Requires Tier 2 Storm Water Pollution Prevention Plan.! Requires submittal of Tier 2
SWPPP, payment of processing fee and review by citr,
I
Post-Development ISUSMPI Compliance
Storm Water Standards Questionnaire complete
Project is subject to Standard Storm Water Requirements. : See city Standard Urban
Storm Water Management Plan (SUSMP) for referen 'e.
hit ://www.carlsbadca. ov/business/buildin /Documents/E Standsw-stds-vol4-ch2. di
Project needs to incorporate low impact development sJrategies throughout in one or
more of the following ways: I
Rainwater harvesting (rain barrels or cistern)
Vegetated Roof
. : Bio-retentions cell/rain garden
Pervious pavement/pavers
Flol(,l-through planter/vegetated or rock drip line
Vegetated swales or rock infiltration swales
Downspouts disconnect and discharge over landscape
!
Othe_r:
5. ADDITIONAL COMMENTS
Page4of4 REV 6/2012
STORM WATER POLLUTION PREVENTION NOTES
1. A1..1 NECESSARY EQUIPWENT ANO MATERIALS SHALL BE
AVAILABLE ~ SITE TO FACILITATE RAPID INSTALLATION
OF EROSION AND SEDIMENT CCtflR<l.. BMPs MiEN RAIN
IS EUINENT.
2. THE ~ER/CONTRACTOR SHALl RESTORE ALL EROSION
CONTROL DEVICES TO Y«>RKING (R[)£R TO niE SA TISf ACllON
OF lHE CITY INSPECTOR AFTER EACH RUN-Off PROOUCING
RAINFAL.L.
3. lHE OYH.R/CONTRACTOR SHALL INSTALl ADDITIONAL. EROSION
CONTROL MEASURES AS MAY BE REQUIRED BY lHE CITY
INSPECTOR DUE TO INCCllPL.ETE GRADING OPERATIONS OR
UNFOOESEEN CIRCUMSTANCES 'MilCH MAY ARISE.
4. All REMOVABI.£ PROlECTI\.£ DE'JICES SHAll. BE IN PLACE
AT 1l£ END CF EAOi WORKING DAY 'M-IEN THE AVE (5)
DAY RAIN PROBABILITY FORECAST EXCEEDS FOOTY PECENT (40%). SILT AND OlHER DEBRIS SHALL B£ RfMOW AFTER
EACH RAINFALL
5. All. GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM
~GAlE.
6. ADEWAlE EROSION AND SEDIMENT CONTROL ANO PERIMrn:R
PROTECTION BEST MANAGEMENT PRACTICE WEASURES MUST
BE lNSTAU.ID AND MAINTAINED.
7. THE CITY INSPECTOR SHALL HA1'£ Tl£ AUlHORllY TO ALTER
1HIS Pl.AN DURtJG OR BEFORE CctlS1RUC110N AS NEEDED
lO ENSURE COMPLIANCE WITH OTY STORM WATER QUALITY
REGUI..A TIONS.
OWNF.RS CERTIFICATE,
I UNDERSTAND AND A~ lHAT I MUST: (1) IMPlEMENT
0CST MANAGEMENT PRAC1IC£S {BUPS} DU~ CONSlRUCTION
ACll\111ES 10 THE I.WCllill.lW EXTENT PRACllCABlE TO A\lem
TI£ lilOBIUZAlDI CF POLLUTANTS SUCH AS SEDIMENT AND TO
AVOI) lHE EXPOSURE CF STtRI WATER TO CONSlRUCllOH
REl.ATED PCllUTANTS; AN) (2) ADHERE TO. AND AT All llMES,
ca.tPL Y 'MTH lHtS CITY APPft(MI) TER 1 ~llON S1f'PP
1HROUGOOUT TI£ DURATIOI CF ll£ CONS1RUC1lON ACTI't1TES
UN11L 1t£ CONSlRl.JC1100 'MlRK IS COMPlE1E AND APPROVED ••
E-29
STORM WATER COMPLIANCE FORM
TIER 1 CONSTRUCTION SWPPP
E-29
CB l le :')<,..c,zq
SW llil -L\l tS
Best Management Practice*
(BMP)°""'1)tion ~ =-~ --
BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE
i i I z z z
,......., =·~ ...... ~~~'.:::::::::::j:::j:::j::::l::t:t:+=::J:~'1=:(:~t:t:=l::::J==::t=1i::i:::(::::t:t:=l::::J==::J:::t:(::::t:::::)::::+:::::::)=1 , Trench ~
Concrete
Concrvte Aotwork
Conckiit Installation
Stucco ,_ -St Down Area
E • t Moi'ltenance Fu
Hanrdous Sub&ttwice Use -· Site Access AerolllS Dirt
other llistl:
IMlruclloo• 1. Check the box to the left of all c;wllcoble construction octMty (first cdumn) expected to occur dtri'lg construction.
2. located along the too of the EM> Table Ill a list of BMP's with it's correaoondlnQ Cmlfornki stormwcrter C),dity Association (CASOA} ~lion ~. Choose one « mere BMPs )'X' rllend to use c:hmg eonatructJcn from the Rat. Check the boi whn the chosen octhity ro11 intersects with the BMP cdumn.
3. Refer to the CASQA constructlan hmdbook fer ilformotlon cm delals of the choeen BMPa and how to apply them to the project.
SHOW THE LOC\TIONS OF ALL CHOSEN BMPs ABOVE
ON THE PROJECTS SITE P!AN,£ROSION CON1ROI. Pt.AN.
SEE THE REVERSE SIDE OF THIS SHEET FOR A SAMPLE
EROSION CONTROL Pt.AN.
-BMP's are subject to field inspection-
Poge 1 of 1
Constn,ction Threat to stonn Water Quaflty
(""'* e..)
OMEDIUII OLDW
"
REV 02/16
.~
··c·cityof
Carlsbad
DETERMINATION OF
PROJECT'S SWPPP
TIER LEVEL AND CONSTRUCTION
THREAT LEVEL
E-32
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carlsbadca.gov
I'm applying for: D Grading Permit
Project Name: f'~t r: .;·, ~ , ".i
ljt Building Permit
Project ID:
pif Right-of-way permit a Other
Address: 11)".:l') r ~ Wr>•• APN l5£.,.:-:'!f>i-Q¢-Q0
DWG #/CB# _____ _
• 1isturbed Area: ----~Ac ,·~· rl J I .....
Section 1: Determination of Project's SWPPP Tier Level
(Check aoolicable criteria and circle the corresoondina SWPPP Tier Level, then ao to section 2l
Exempt -No Threat Project Assessment Criteria
My project is in a category of perrntt types exempt from City Construction SWPPP requirements. Provided
no significant grading proposed, pursuant to Table1, section 3.2.2 of Storm Water Standards, the
following permtts .afB exempt from. SWPPP requiremeqts: ....... . .... ··· ....... . ...........•...... ]
: l> Electrical ! l> Patio ! l> Mobile Home ! l> Plumbing ! l> Spa (Factory-Made) , L~··:Fi~s~;;~;;j~;··r;--M~;·~~i~~i·· I ·;···-R~~R~~~:~;;···-···r;·:::·:·si;;~··········:1;·····R·~~;:;;;~~~;dS~.i~;·A;~~····1
Tier 3-Significant Threat Assessment Criteria -(See Construction General Permit (CGP) Section I.BJ*
D My project includes construction or demolition activity that results in a land disturbance of equal to or
greater than one acre including but not limtted to clearing, grading, grubbing or excavation; or,
D My project includes construction activity that results in land disturbance of less than one acre but the
construction activity is part of a larger common plan of development or the sale of one or more acres
of disturbed land surface or,
D My Project is associated with construction activity related to residential, commercial, or industrial
development on lands currently used for agriculture; or
D My project is associated with construction activity associated with Linear Underground/overhead
Projects (LUP) including but not limited to those activities necessary for installation of underground
and overhead linear facilities (e.g. conduits, substructures, pipelines, towers, poles, cables, wire,
towers, poles, cables, wires, connectors, switching, regulating and transforming equipment and
associated ancillary facilities) and include but not limited to underground utility mark out, potholing,
concrete and asphalt cutting and removal, trenching, excavation, boring and drilling, access road,
tower footings/foundation, pavement repair or replacement, stockpile/borrow locations.
D Other per CGP
Tier 2-Moderate Threat Assessment Criteria: My project does not meet any of the Significant Threat
Assessment Criteria described above and meets one or more of the following criteria:
D Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the
Carlsbad Municipal Code); or,
D Project will result in 2,500 square feet or more of soils disturbance including any associated
construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance
areas and project meets one or more of the additional following criteria:
• located within 200 feet of an environmentally sensitive area or the Pacific Ocean; and/or,
• disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical; and/or
• disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or
watercourse; and/or
• construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1
throuah Aor. 30).
Tier 1 -Low Threat As•0 ssment Criteria
~ My project does not meet any of the Significant or Moderate Threat criteria above, is not an exempt
permit type per above and the project meets one or more of the following criteria:
• results in some soil disturbance; and/or
• includes outdoor construction activities (such as roof framing, saw cutting, equipment washing,
material stockpilino, vehicle fuelina, waste stockpilinn\
SWPPP
Tier Level
Exempt
Tier3
Tier2
Tier 1
* Items listed are excerpt from CGP. CGP governs cntena for triggers for Tier 3 SWPPP. Developer/owner shall confirm coverage
under the current CGP and any amendments, revisions and reissuance thereof.
E-32 Page 1 of2 Rev. 2116/16
SW PPP Section 2: Determination of Project's Construction Threat Level
Tier (Check applicable criteria under the Tier Level as determined In section 1, circle Construction
Level the corresponding Construction Threat Level, then complete the Threat Level
sinnatu re block below I
Exempt -Not Applicable -Exempt
Tier 3 -High Construction Threat Assessment Criteria: M~ Project meets one or more of the
following:
D Project site is 50 acres or more and grading will occur during the rainy season
D Project site is located within the Buena Vista or Agua Hedionda Lagoon watershed,
inside or within 200 feet of an environmentally sensitive area (ESA) or discharges directly
to an ESA High
D Soil at site is moderately to highly erosive (defined as having a predominance of soils
Tier3 with USDA-NRCS Erosion factors kf greater than or equal to 0.4)
D Site slope is 5 to 1 or steeper
D Construction is initiated during the rainy season or will extend into the rainy season (Oct.
1 -April 30).
D Owner/contractor received a Storm Water Notice of Violation within past two years
Tier 3 -Medium Construction Threat Assessmen! Criteria Medium D All projects not meeting Tier 3 High Construction Threat Assessment Criteria
Tier2 High Construction Threat Assessment Criteria: M~ Project meets one or more of
the following:
D Project is located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or
within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an
ESA
D Soil at site is moderately to highly erosive (defined as having a predominance of soils High
with USDA-NRCS Erosion factors k, greater than or equal to 0.4)
Tier2 D Site slope is 5 to 1 or steeper
D Construction is initiated during the rainy season or will extend into the rainy season (Oct.
1-Apr. 30).
D Owner/contractor received a Storm Water Notice of Violation within past two years
D Site results in 10,000 sq. ft. or more of soil disturbance
Tier 2 -Medium Construction Threat Assessment Criteria Medium D My project does not meet Tier 2 High Threat Assessment Criteria listed above
Tier 1 -Medium Construction Threat Assessment Criteria: M~ Project meets one or more
of the following: ,2 Owner/contractor received a Storm Water Notice of Violation within past two years Medium · Site results in 500 sq. ft. or more of soil disturbance
Tier1 0 Construction will be initiated during the rainy season or will extend into the rainy season
(Oct.1-April 30)
Tier 1 -Low Constructioo Threat Assessment Criteria Low D My project does not meet Tier 1 Medium Threat Assessment Criteria listed above
I certify to the best of my knowledge that the above statements are true and correct. I will prepare and submit an appropnate lier level SW PPP as determined above
prepared in accordance with the City SWPPP Manual. I understand and acknowledge that I must adhere to and comply with the storm water best management
practices pursuant to Tnle 15 of the Carlsbad Municipal Code and to City Standards at all times during construction activities for the permit type(s) checked above.
The City Engineer/Building Official may authorize minor variances from the Construction Threat Assessment Criteria in special circumstances where it can be shown
that a lesser or higher SWPPP Tier Level is warranted.
Owner/OWnlll's Authorized Agent Name: Title: City Concurrooce: Yes No
(For City Use Only)
By.
Date:
Project ID:
E-32 Page 2 of 2 Rev. 2/16/16
4~
"' ~:)y ~ CITY OF
CARLSBAD
PLANNING DIVISION
BUILDING PLAN CHECK
APPROVAL
P-29
DATE: 9/26/16 PROJECT NAME: POOL/SPA PROJECT ID:
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.e-ov
PLAN CHECK NO: CB163629 SET#: ADDRESS: 1222 ESMAT WY APN:
i:gJ This plan check review is complete and has been APPROVED by the PLANNING
Division.
By: GINA RUIZ
A Final Inspection by the PLANNING Division is required D Yes ~ No
You may a/so have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check APPROVAL has been sent to: ROB@MAJESTICPOOLS.NET
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING ENGINEERING FIRE PREVENTION
760-602-4610 760-602-2750 760-602-4665
D Chris Sexton D Chris Glassen D Greg Ryan
760-602-4624 760-602-2784 760-602-4663
Cbri~.S~xton~carlsbatt,a.gov Christog,her.Glassen@carlsbadca.gov Gregor~.R~an@carlsbadca.gov
~ Gina Ruiz D Val Ray Marshall D Cindy Wong
760-602-4675 760-602-27 41 760-602-4662
Gina.Ruiz@carlsbadca.ggv YalR<1y.Marshall@carlsbadca,gov Cynthia.V',(Qng@carlsbadca.gq~
D Veronica Morones D Linda Ontiveros D Dominic Fieri
76o-602-4619 760-602-2773 760-602-4664
Veronica.Moron~s@c11rlsba'1ca.gov Linda.Ontiveros@carlsbadca.gov Dominic.Fieri@carlsbadca.gov
Remarks:
\0
@~
1 /2G /(h
to(i f,1o
C-11'(.lt ~ ~ '9 o~/JC-<L-:tt lo /b/lb
ID I II I I\.
10(12/11.,
@.re
12-TI / "1, v,A:--c=-..-cA,~
Final Inspection
D Plan
required by:
QCM&I 1:J Fire
SW 1111-O.,,t:; l:JJSSUED
Approved Date
BUILDING
PlANNJNG cr1 zc;, 7,,
ENGINEERING 10ft i11 b
FIRE Expedite7 y N
DIGITAL FILES Reauired7 y N
HazMat
APCD
Health
Forms/Fees Sent Rec'd
Encina
Fire
HazHealthAPCD
PE&M
School
Sewer
Stormwater
Special Inspection
CFO: y N
D
Land Use: Density: rmpArea: FY, Annex:
PFF: y N
Comments Date Date Date
Building
Planning
Engineering \o/"b /,re ,
Fire
Need?
I Dev . ....
°'"--
\) "\
Due? By
y N
y N
y N
y N
y N
y N
y N
y N
Factor:
Date
0 Done
ODone
DDone
CJ Done