HomeMy WebLinkAbout1239 KNOWLES AVE; ; CB911284; PermitB U I L D I N G P E R M I T Permit No: CB911284
03/13/92 15:32 Project No: A9101610
Page 1 of 1 Development No:
Job Address: 1239 KNOWLES AV Str: Fl: Ste:
Permit Type: RESIDENTAL ADD/ALT (OVER 10K) 6789 03/13/92 0001 01 02
Parcel No: 156-164-54-00 C-PRMT 29..00
Valuation: 37368
Construction Type: VN
Occupancy Group: R3 - Class Code: Status: ISSUED
-Description: 519 SF RESIDENTIAL ADDITION Applied: 09/12/91
Apr/Issue: 12/11/91
Validated By: SBB
Appl/Ownr : COPELAND, STEPHEN (619)729-1065
1239 KNOWLES AV
CARLSBAD, CA 920 -8
*** Fees Required ted & Credits
Fees: 646. 0g) ( \ Adjustments: / \oo .00
Total Fees: I 62..b.0.0 To'tal Paymetj2: \ 597.00
I I B alan e'tce: \ 29.00
560.00
Enter
• Building Permit ( •. . .
337.00
Plan Check f 219.00
-00 Strong Motion Fee . / ) 4.
* BUILDING TOTAL / / 560.00
Enter "1" for 'Plumbing Isse ee 7.50 Y
Each Plumbing Fixture or Trap > 4 / 2.59' 10.00
Each Building Sewer \ \ -~CORPORATED 1/ 6.51b 6.50
Each Water Heater and /or(t 2..'50 2.50
Gas Piping System \ 4 > 2K50 2.50
* PLUMBING TOTAL 29.00
Enter "Y" for Remodel 10.00 y
* ELECTRICAL TOTAL ($10 Minimum) • 15.00
Enter
•'' for Mechanical Issue Fee> 15.00 Y
Each Hood/Fireplace > . 1 6.50 6.50
* MECHANICAL TOTAL ' 22.00
'• p /.........
JI1AI?**ROVAL
INSP. \- DATE.
CLEARANCE
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
DATE:
PERMIT APPUCATION
City of Carlsbad Building Department
2075 Las Patinas Dr.,, Carlsbad, CA 92009 (619) 438-1161
PLAN CHECK NO. 47/_
FSF. VAI
PLAN cIK
1. PERMIT TYPE
A - LI Commercial U New Building U Tenant Improvement
B - 0 Industrial 0 New Building 0 Tenant Improvement
C - Residential 0 Apartment 0 Condo 0 Single Family Dwelling 'Addition/A1teration
0 Duplex U Demolition 0 Relocation 0 Mobile Home U Electrical 0 Plumbing
U Mechanical 0 Pool U Spa 0 Retaining Wall 0 Solar 0 Other__________
2. PRUJECT INFORMATION 1 FOR OFFICE USE ONLY
Address s23 9 I<NOi)L fl<. Building or Suite No.
Nearest Cross Street D b P1 C
LEGAL DESCRIPTION Lot No. jbdivision Name/Number Unit No. Phase No.
CHECK BELOW IF SUBMIYFED:
02 Energy Calcs 02 Structural Calcs 02 Soils Report 0 1 Addressed Envelope
ASSESSOR'S PARCEL EXISTING USE o1 4 02
DESCRIPTION OF WORK
PAM C-PPHT 21.60
SQ. FT. fl Al # OF STORIES J 3. WN1AS.A (ii iiFerent from applicant)
NAME ADDRESS
CITY
APPLICANT
STATE ZIP CODE DAY TELEPHONE
U CONTHACIUR
NAME j
U AGENT FOR
cop ()ysC
CONTRACIUR .OWNER
ADDRESS 2 39 U AGENT FOR OWNER
)<JOCA)L.e S 4U€..
STATE ('4, ZIP CODE p DAY TELEPHONE 79 Iñe'05
NAME S AmC ADDRESS
CITY
CDNTRACTOR
STATE ZIP CODE DAY TELEPHONE
NAME ADDRESS
CITY STATE ZIP CODE DAY TELEPHONE
STATE CC. # LICENSE CLASS CITY BUSINESS CC. #
DESIGNER NAME ADDRESS
CITY STATE ZIP CODE DAY TELEPHONE STATE CC. # WORKERS' WMFENSATION
Workers' Compensation Declaration: I hereby affirm that I have a certificate of consent to sell-insure issued by the Director of Industrial
Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified
by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C).
INSURANCE COMPANY POLICY NO. EXPIRATION DATE
Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner
so as to beco subj t e #rs' Compensation Laws of California.
SIGNATU (DATE /9'f
OWNER- -
Owner- uilder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or
offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property wh6builds
or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended
or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden
of proving that he did not build or improve for the purpose of sale.).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions
Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such jrojects
with contractor(s) licensed pursuant to the Contractor's License Law). -
0 I am exempt under Section Business and Professions Code for this reason:
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or,repair
any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuanè'io the
provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and ProfessionCode)
or that he is exempt the efrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for i permit subjects t a licant o ,.eyi) penalty ot ore than five hundred dollars [$5001).
SIGNATURE . - ( - DATE 9
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and
prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?
DYES ONO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management-district? DYES ONO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?
DYES ONO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT
HAS MET OR IS MEETING THE REQUIREMENTS OF ThE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CX)N1I1OL DIS11UCF.
WNSIRUCIION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances andState laws
relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS CDSTS
AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF ThIS PERMIT.
OSHA-* An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the
building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by
such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code).
CITY OF CARLSBAD
INSPECTION REQUEST
PERMIT#CB911284 FOR 10/20/92 INSPECTOR AREA MP
DESCRIPTION: 519 SF RESIDENTIAL ADDITION PLANCK# CB911284
0CC GRP R3
TYPE: RADMAJ CONSTR. TYPE VN
JOB, ADDRESS: 1239 KNOWLES AV STR: FL: STE:
APPLICANT: COPELAND, STEPHEN PHONE: (619)729-1065
CONTRACTOR: PHONE:
OWNER: PHONE: A (1 I
REMARKS: MH/STEVE/729-1065
SPECIAL INSTRUCT:
TOTAL TIME:
--RELATED PERMITS--' PERNIT# TYPE
CB900888 RAD
CD LVL DESCRIPTION
19 ST Final Structural
29 PL Final Plumbing
39 EL Final Electrical
49 ME Final Mechanical
INSPECTOR LkO~ _________________
STATUS
EXPIRED
ACT COMMENTS
H
INSPECTION HISTORY *****
DATE DESCRIPTION
052292 Gas/Test/Repairs
031792 Frame/Steel/Bolting/Welding
031792 Frame/Steel/Bolting/Welding
031392 Frame/Steel/Bolting/Welding
022492 Grout
020492 Footing -
020392 Footing
012492 Ftg/Foundation/Piers
ACT INSP COMMENTS
AP NP
PA NP FLOOR SHEATHING NAILING
AP NP SUB FLOOR
PA NP SUB FLOOR
AP - NP
CO NP
CA MP • PER OWNER
AP NP
PROJECT ADDRESS
P-ROJECT NAME:
SET:
Ia.?A thJ.
LIFILE COPY
JUPS
DESIGNER
PLAN CHECK NO:
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619)560-1468
DATE: 401 flAP
JURISDICTION:
DICT
M.
The plans plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
__ The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies. identified SeaR-rv-p-c S'oj are resolved and
checked by building department staff.
L The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
fl The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
fl The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
Esgil staff did not advise the applicant contact person that
plan check has been completed.
[] Esgil staff did advise applicant that the plan check has
been completed. Person contacted:
Date contacted:________________ Telephone #______________ 10M IN REMARKS: (j) .9f-?4) ',J,J (V7/AJ) ') T ST-E-7--S
fD V/2 A CD,(J r/.'is 1C66 T/,tJC 7Z Per - 2 /4-j55s
Ar --
/17 S. IJ07766 )77r7)1? 'AJ /°4-J$.
By:S)'i7 AL.Et-7 Enclosures:
ESGIL CORPORATION
LIGA LICM
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: /
JURISDICTION: CARLSBAD
PLAN CHECK NO:. SET:
PROJECT ADDRESS:
PROJECT NAME: t5, F-
ThTR I S I CT ION
JPLAN CHECKER
[]FILE COPY nups
ÜDESIGNER
The plans transmitted herewith have beencorrected where
necessary and substantially comply with the jurisdiction's
building codes.
E The plans trànsmitted herewith will substantially comply
with the jurisdiction's-building codes when minor deficien-
des identified . are resolved and
checked by building department staff.
L The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
fl The applicant's copy of .the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The. applicant's copy of the check list has been sent to:
57flEAJ PtA-J /23 Aii Ave
Esgil staff-did not advise the applicant contact person that
plan check has been completed.
0 Esgil staff did advise applicant that the plan check has
been completed. Person contacted:
Date contacted-: Telephone
REMARKS:
By: Sy__ Ate Enclosures:
-ESGIL CORPORATION
El GA - 0 AA U RN 0DM
JURISDICTION: CITY OF CARLSBAD
PLAN C1MKK NO: 9/-iz
PROJECT ADDRiSS:'' kLCS 4J
PLAN CORRECTION. SHKT
CITY OF_CARLSBAD
SINGLE FAMILY AND DUPLEX DWELLINGS
FORRD:PLEASE READ
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the
handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections based
on laws and ordinances by the Planning Department,
Engineering Department or other departments.
Present California. law mandates that residential
construction comply with Title 24 and the following
model codes:
1988 UBC (eff. 1/1/90)
1988 UPC (eff. 1/1/90)
1990 NEC (eff. 7/1/91)
1988 UMC (eff. 1/1/90)
The above regulations apply to residential
construction, regardless of the code editions
adopted by ordinance.
The circled items listed need clarification,
modification or change. 'All items have to be
satisfied before the plans will be in conformance
with, the cited codes and regulations. Per Sec.
303(c), 1988 Uniform Building Code, the approval of
the plans does -not permit the violation of any
state, county or city law.
To soeed um the recheck Drocess. note on this list
(or a _copy) _where each correction item has been
addressedi.e.,plansheet,specification,etc.Be
sure 'toenclosethemarkeduplistwhenyousubmit
therevisedplans.
FLOOR AREA: F (i17D)
I.
HE:
Date plans received by jurisdiction:
Date plans received by Esgil Corporation:
Date initial plan check completed:
By:Y
Applicant contact person:-
-
List No. 12, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1988 UBC)
PLANS
T) please make all Corrections on the original
tracings and submit two new sets of prints, and
any original plan sets that may have been
returned to YOU by the jurisdiction, to:
Esgil Corporation, 9320 Chesapeake Drive,
Suite #208, San Diego, California 92123,
(619),560-1468. -
2/. Please make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have been
returned to you by the jurisdiction, to:
The jurisdiction's building department.
Indicate on the Title Sheet of the plans, the
name of the legal owner and name of person
responsible for the preparation of the plans.
Section 302(a)7.
D All sheets of plans dust be signed by the
person responsible for their preparation.
(California Business and Professions Code).
5. Plans, specifications and calculations shall be
signed by the California state licensed
engineer or architect. responsible for their
preparation, for plans deviating from
conventional wood frame construction. Specify
expiration dat of license. (California
Business and Professions Code).
Specify on the Title Sheet of the plans the
gross floor area of each element of this
project including dwelling, garage, carport,
patio, deck and balcony. Section 302(d).
PP!17/J 1/-2f
7. Provide a statement on the Title Sheet of the
plans that this project shall comply with Title 214 and 1988 UBC, UMC and UPC and 1990 NEC.
'. Submit fully dimensioned plot plan drawn to / scale showing location, size, and use of all
existing and proposed structures on the lot.
Identify property lines and show lot dimensions
and all easements. Show location of all cut or
fill slopes. Show finish floor elevations and
show elevations of adjacent finish grade.
Show drainage patterns with minimum slopes.
Section 302(d). :
Indicate distance from property lines to I proposed building. Section 302(d).
Show on the title sheet all structures, pools,
( walls, etc. included under this application.
Any portion of the project shown on the site
plan that is not included with the building
permit application filed should be clearly
identified as "not included."
l. Clearly show if the lower level is a basement
or a story, based on the definitions in
Sections 403 and 420. Plot the finish grade
(as defined) on the elevations and dimension
the distance to the floor above, for story
determination.
]fz. On the cover sheet of the plans, specify any
[ items requiring special inspection, in a
format similar to that shown below or sticky
back.
REQUIRED SPECIAL INSPECTIONS
In addition to the regular inspections, the
following checked items will also require
Special Inspection in accordance with Sec. 306
of the Uniform Building Code.
ITEM REQ. IF RE?1APJ(S
CHECKED
SOILS COMPLIANCE
PRIOR TO
FOUNDATION INSP.
STRUCTURAL CONCRETE
OVER 2500 PSI
PRESTRESSED STEEL
FIELD WELDING
HIGH STRENGTH BOLTS
EXPANSION ANCHORS
SPECIAL MASONRY
SPRAYED ON FIRE
PROOFING
PILES/CAISSONS
DESIGNER-SPECIFIED
OTHER
Exterior walls closer than 3 feet to property
/ lines shall be one-hour rated construction and
have no -openings. Table 5-A.
7/9/91 . 2
iL. Exterior walls closer than 3 feet to a property
/ line shall have 30 inch parapets when the floor
area per floor exceeds 1,000 square feet.
Section 1709.
h. Projections, including eaves, may not extend
/ more than 12 inches into the 3 foot setback
from the property line. Section 1710.
l. Eaves over required windows shall be not less
I than 30 inches from the side and rear property
lines. Section 504.
Openable window area in habitable rooms must
be 1/20 of the floor area and a minimum of 5
square feet. In bathrooms, laundry rooms and
similar rooms 1/20 of area is required and
minimum is 1.5 sq. ft. Section 1205 (a).
2/4. At least 1/2 of the common wall must be open
I and have an opening not less than 25 sq. ft.
nor one tenth of the floor area of the
interior room if light and ventilation is
being supplied from an adjacent room. Section
1205 (a).
Plastic skylights shall not be installed within 2. Required windows shall not open into a roofed that portion of a roof located within a porch unless the ceiling height is at least 7 distance to property line where openings in feet, the longer side is at least 65% open, exterior walls are prohibited or required to be and the porch abuts a street, yard or court. protected. Section 5207 (a) 7. Section 1205 (a).
Projections, including eaves, shall be one- 216. Provide mechanical ventilation capable of hour fire-resistive construction, heavy timber providing five air changes per hour in or of noncombustible material if they project / bathrooms, water closet compartments, laundry into the 3' setback area from the property rooms and similar rooms if required openable line. Section 1710. windows are not provided. Section 1205 (c).
1. Show location of permanently wired smoke 2/1. Show discharge point for exhaust air to be at
detector: I least 5 feet from any mechanical ventilating Centrally located, in corridor or area intake. Section 1205(c). giving access to sleeping rooms.
On each story. 28. Ductless fans cannot be used in bathrooms if a C. In the basement, 1 tub or shower is present. Section 1205(c). d. When sleeping rooms are upstairs, at the
upper level in close proximity to the 29. No habitable room, other than a kitchen, shall stair. I be less than 7'0" in any dimension. Section e. In rooms adjacent to hallways serving 1207 (c). bedrooms, when such rooms have a ceiling
height 24 inches or more above the ceiling .30. Show that ceiling height for habitable rooms height in the hallway. "-.----' is a minimum of 7'6". Section 1207 (a). NOTE: •Detectors shall sound an alarm audible in
all sleeping areas of the unit. Section 1210 31. Show ceiling height for laundry rooms, I hallways, corridors, and bathrooms is a 20. When the valuation of a room addition or repair minimum of 7'0". Section 1207 (a). exceeds $1,000, or when sleeping rooms are • created, smoke detectors shall be provided at 3'2. Dimension on the plans the 30" clear width for existing bedrooms,per item 19 above. Section / water closet compartments and 24" clearance in 1210. front of water closet. Section 511 (a).
GENAL RIDTI.AL RJIRFXIS Specify safety glazing for glazing in L -
. hazardous locations such as glass doors, Habitable rooms, other than kitchens, shall glazing adjacent to doors and glazing adjacent contain at least 7.0 square feet of floor area. to walking surfaces. Section 5406. At least one room shall have not less than 120 C/2_ 6L-!'/f.Z •L./- L-' square feet of floor area. Section 1207 (b). Glazing, in the same wall plane as a door, / must be safety glazing if within 12" of the 2/2. Window area must be at least 1/10 of the floor door and less than 60" above the walking area and a minimum of 10 square feet per surface, unless the glazing is leaded or Section 1205 (a). Appears to be deficient in ' faceted glass. Section 5406 (d) 6.
Is. Glazing in shower and tub enclosures shall be
/ tempered, laminated or approved plastic (including windows within 5 feet of tub or
shower floor). Section 5406 (d) 5.
2/12/90 3
Sleeping rooms shall have a window or exterior
door for emergency exit. Sill height shall not
çj1 45. Provide stairway and landing details. Section
( 3306 (b), (c) and (p).
exceed 64" above the floor. The window must
have an openable area of at least 5.7 square v3 Maximum rise is 7" and minimum run is
feet with the minimum openable width 20" and 11". When the stairs serves less than 10
the minimum openable height 26". Section 1204. occupants, or serves an unoccupied roof,
I rise may be 8" maximum and run 9"
3f7. Basements in dwelling units shall comly with minimum.
the above (even if not designated as sleeping
rooms). Section 1204. 7. Minimum headroom is 6'-8".
3. Walls and floors separating units in a duplex C'. Minimum width is 36".
shall be of one-hour fire-resistive W
_
/
construction. Section 1202(b).46. All handrails per Section 3306 (j), shall
/ satisfy the following:
.3/?. A mezzanine is an intermediate floor and may
not have a floor area exceeding 33 1/3 percent (9 Provide handrail for stairways with 4 or
of the total floor area in .the room below. The more risers.
mezzanine floor must have a clear height of 7
feet, above and below, and must have the long (9 Handrail shall be 34" to 38" above the
side open to the room below except for posts nosing of treads.
and protective walls or railings not exceeding
• 42" in height. Section 1716. (9 The handgrip portion of handrail shall be
I not less than 1 1/2", nor more than 2" in 49. The loft you show. does not comply as a cross-sectional dimension.
/ mezzanine floor and is, by Uniform Building
Code definition, a story. Section 1716. 67. Every stairway landing shall have a dimension,
/ measured in the direction of travel, at least
EXITS. STAIRWAYS, AND RAILINGS equal to the stairway width. Such dimension
1 need not exceed-36 inches. Section.3306 (g),
41. - Floors above the second story shall have not
less than 2 exits. Exceptions: 1. Occupied 3304 (j).
roofs may have one exit if such occupied areas
are less than 500 square feet and located no Ld8. An interior door may open inward at the top
higher than immediately above the second story. / step of a stairway provided the top step is
2. When the third floor within a unit does not not more than 7 1/2" lower than the floor
-exceed 500 sq. ft., only one exit need be level. Section 3304 (i).
provided. Section 3303(a).
4'9. Provide details of winding stairway complying
4. Required exit doorways shall be not less than I with Section 3306 (d):
36" in width and not less than 6'8" in height,
and shall be capable of opening at least 90 a. Minimum tread is 6 inches at any point
degrees. Section-3304 (f). - / and minimum 9 inches at a point 12 inches • from where the treads are narrowest. 4,5. Provide 36" high protective railing for
porches, balconies,- and -opensides-- of stair - ---b. Maximum rise is 8 inches.
landings. Openings between railings shall be -
less than 6". Section 1711. • C. Minimum width is 36 inches. It f 4/.. Show how guardrail connection details are
adequate to support 20 pounds per lineal foot
at a right angle to the top rail. Table 23-B.
5/10/90 4
5b. Provide spiral stairway details, per Section
3306 (f):
. Minimum run is 7 1/2 inches measured at a
point-12 inches from where the treads are
the narrowest.
Maximum rise is 9 1/2 inches. Maximum / clear opening between risers is 6 inches.
Minimum headroom is 6 feet 8 inches
d. The tread must provide a clear walking
area measuring at least 26 inches from the
outer edge of the supporting column to the
inner edge of the handrail.
5l. Spiral stairways may not be used for required
exits when the area served is.. greater than 400
sq. ft. Section 3306 (f).
Provide I.C.B.0. Research Report and number for
metal stairway, or submit plans and
calculations and approved fabricator registered
with the building department or note' that the
stairway fabrication plans shall be submitted
to and approved by the building official prior
to installation.
'Exterior stairways shall not project into the 3
foot setback from the property lines. Section
3306 (n).
5L. The walls and soffits of the enclosed usable
space under interior stairs shall be protected
on the enclosed side as required for one-hour
fire-resistive construction. Section 3306 (m).
5. Within units, show that corridors have a
minimum width of 36 inches. Section 3305 (b).
ROOFING
Specify roof slope.
5j. Roof slope is ..not adequate for roof type I specified. Table 32-B,C,D and E.
Specify roof material id application. chapter
6. Specify I.C.B.0. or U.L. approval number for
roof materials not covered in IJ.B.C., e.g.,
tile, etc.. Section 107.
Specify minimum 1/4 inch per foot roof slope
I for drainage or design to support accumulated
water. Section 3207 (a) and Section 2305 (f).
6j. Provide skylight details to show compliance
I with Sections 3401 and 5207 or provide
I.C.B.0. approval number.
63. Plastic skylights must be separated from each / other by at least 4 feet. Section 5207 (a) 6.
6jL. Show attic ventilation., Minimum vent area is
1 1/150 of attic area or 1/300 of attic area if
at.least 50% of the required. vent is at least
3 feet above eave vents or cornice vents.
Show required area and area provided.
Section 3205 (c).
MASONRY
6'S. Provide fireplace construction details or note I construction to be per attached fireplace
standard drawing. chapter 37.
Show anchored veneer support and connections
attached to wood in Seismic Zones 3 and 4,
comply with Section 3006 (d)1 and Section 2515
(a). Show ties and #9 wire in horizontal
joints.
Show height and construction details of all
masonry walls. Chapter 24.
Show floor and roof connections to masonry
walls. Connection shall resist 200 pounds per
lineal foot or the actual design load,
whichever is greater. Cross grain tension or
bending in wood ledgers is not permitted.
Section 2310.
Show a minimum 2" air space and flashing
between-planter and building walls.
Section 2516 (c) 7.
GARAGE AND CARPORTS
7p. Garage requires one-hour fire protection on
the garage side of walls and ceiling common to
the dwelling. Table 5-B, Section 503 (d).
A. All elements supporting floor above garage, I including walls supporting floor joists, must
have one-hour fire-resistive protection on the
garage side. Section 503 (b)
12. Show 1 3/8" solid core self-closing door for
openings between garage and dwelling. Section
503 (d).
73. Garages are not permitted to open into a room
used for sleeping purposes. Section 1104.
i. Show roof drains and overflows. Section 3207.
12/18/90 ' 5
An occupancy separation is not required between
carport and residence, provided the carport is open on two or more sides and has no enclosed
uses above. Section 503 (a) Exception 3.
75. Show garage framing sections, size of header
over garage opening, lateral cross bracing at
plate line, method bracing garage front and holddowns if required. chapter 23.
NOTE: Maximum shear panel height-to-width ratio is 3 1/2 to 1 for plywood. Table 25-I.
Doors may open, into the garage only if the floor or landing in the garage. is not more than
one inch lower than the door threshold.
Section 3304 (i).
7. Provide an 18" raised platform for any FAU,
water heater, or other device in the garage which may generate a flame or spark. UMC
Section 508, UPC Section 1310 (a).
FOUNDATION RIJIRTS
78. Per soils report, note on the plan the soils
classification, whether or not •the soil is
expansive and note the allowable bearing value.
Section 2905 (c).
7p. The foundation plan does not comply with the
soils report recommendations for this project.
Please review the report and modify design,
notes and details as required to show
compliance: -
O. Provide notes on the foundation plan listing
the soils report recommendation for
foundations, slab and building pad preparation.
81 Provide a letter from the soils engineer
confirming that the foundation plan, grading
plan and specifications have been reviewed and
that it has been determined that the ecoendations.jn the .soj1s ,reportare.
properly incorporated into' the construction
documents (when required by thel soil report).
82. The soils engineer recommended that he/she
review the foundation excavations. Note on
the foundation plan that "Prior to the
contractor requesting a Building Department
foundation inspection, the soils engineer
shall advise the building official in writing
that:
I. The building pad was prepared in
accordance with the soils report,
The utility trenches have been properly
I backfilled and compacted, and
The foundation excavations comply with
the intent of the soils report".
§3. Show height of all foundation walls. Chapter
1 23.
8. Show height of retained earth on all
/ foundation walls. chapter 23.
8. If cut or fill slopes exist, show distance of
foundation to edge of cut or fill slopes and
show steepness and heights of cuts and fills.
Chapter 29.
816. Note on plans that wood shall be 6" minimum
abovefinish grade. Section 2907 (a).
87. Note on plans that surface water will drain
away from building and show drainage pattern
and key elevations. Section 2905 (f).
8j3. Dimension foundation per U.B.C. Table 29A:
Floors Footing
Supported Stemwall Width Depth Thickness
1 6" 12" 12" 6"
2 8" 15" 18" 7"
3 10" 18" 24" 8"
Foundations may support a roof in addition to the
floors. Where only a roof is supported, use
foundation forone floor.
89. Show foundation sills to be pressure treated,
or equal. Section 2516 (c) 3.
9,0. Show, foundation bolt size and spacing.
Section 2907 (f).
91. Specify size, I.C.B.0. number and manufacturer
/ of power driven pins. Show edge and end
distances and spacing. Section-302 (d).
2/13/90 . . -6
I I
92. If required, show size, embedment and location
of hold down anchors on foundation plan.
Section,302 (d).
g. If hold downs are required, 'note on plan that
/ hold down anchors must be tied in place prior
to foundation inspection. Section 305 (e) 1.
9L. Show adequate footings under all bearing walls
/ and shear walls. Section 2907 (b).
Show on the plans stepped footings for slopes
I steeper than 1:10. Section 2907 (c).
Show minimum 18" clearance from grade to bottom
of floor joists 'and minimum 12" clearance to
bottom ofir&e,r_s,. Section 25l T
I-,
Show pier size,spacing and' depth into
'---' undisturbed soil. Table 29-A.
Show minimum underfloor.access of 18" x 24"
Section 2516 (c).
.99.) Show minimum underfloor ventilation equal to-1
sq. ft. for each 150 sq. ft. of underfloor
area. Openings shall be as close to corners as
practicable and shall provide cross ventilation
on at least two approximately opposite sides.
Section 2516 (c) 6.
FRG
10. Show wall' bracing. Every exterior wood stud wall and main cross-stud partition shall be
braced at each end at least every 25 feet of
length with 1 x 4 diagonal let-in braces or
equivalent. Section 2517 (g) 3, Table 25-V.
19l. In 2-story buildings, shear panels at the first
story (at least 48 inches in width) shall be
located at each end or as near thereto as
possible and comprise at least 25 percent of
the linear length of the wall, or provide
design. Section 2517(g)3, Table 25-V.
Note cross bridging or blocking. Floor joists
and rafters 12"o more, in depth shall.be
supported laterally by bridging at intervals
not exceeding 8 feet, unless both, edges are
held inline. Sec. 2506 (Ii), 2517 (d) 6.
Show blocking at ends and at 'supports of floor
joists, rafters and trusses 'at exterior walls.
Section 2517 (d) 3, 2517 (h) 6.
1)4. Bearing partitions, perpendicu'lar' to 'joists,
shall not be offset from supporting girders,
beams, walls or partitions, more than the depth
of the joist. Section 2517 (d) 5.
115. Show rafter ties. Rafter ties shall be spaced
not more than 4 feet on center and be just
above the ceiling joists, where rafters and
ceiling joists are not parallel. Section 2517
(h) 4.
IC)Ô. Show rafter purlin braces to be not less than
45 degrees to the horizontal.
Section 2517 (h) 5.
147. Show double top plate with minimum 68" lap
I splice. Section 2517 (g) 2.
108. Show nailing will be in compliance with Table
25-Q.
1q9. Show or note fire stops at the following
locations per Section 2516 (f):
A. In concealed spaces of stud walls and
I partitions, including furred spaces, at
the ceiling and floor levels and at 10
foot intervals along the length of the
wall;
At all interconnections between concealed
vertical and horizontal spaces such as
occur at soffits, drop ceilings and cove
ceilings;
C. In concealed spaces between stair
stringers at the top and bottom of the
run and between studs along and inline
with the run of stairs if the walls under
the stairs are unfinished; and
In openings around vents, pipes, ducts,
chimneys, fireplaces and similar openings
which afford a passage for fire at
ceiling and floor levels, with
noncombustible materials.
l)O. In duplexes, draft stops shall be provided in
floor-ceiling assemblies and attics in line
with walls separating units and separating
units from common areas.
:.l.l'.•,Show,stud size.and. spacing— Ma.ximum allowable
stud heights: Bearing wall: 2 x4 and 2 x 6
max. 10'; Non-bearing: 2 x 4 max. 141, 2 x 6 max. 201. Table 25-R-3.
12. Studs supporting two floors, a roof and
ceiling must be 3 x 4 or 2 x 6 at 16" o.c.
Table 25-R-3.
43. Note on A.I.T.C. Certificate of Compliance for
glued laminated wood members shall be given to
the building inspector prior to installation.
Section 2505.
/91 '.
. 7
ij. Detail all post-to-beam and post-to-footing
connections and reference the detail to the
plan. Section 2516 (in).
15. Detail shear transfer connections, including
I roof and floor diaphragms, to shear walls.
Section 2513.
ll'6. Specify nail.size and spacing for all shear
I walls, floor and roof diaphragms. Indicate
required blocking. Maintain maximum diaphragm
dimension ratios. [Tables 25 I, .1, K and
Section 4714 (d)].
177. Provide truss details and truss calculations
for this project. Specify truss identification
numbers on the plans.
11'8. Show 1/2" minimum clearance between top plate
/ of interior partitions and bottom chord of
trusses. (To ensure loading will be as
designed).
19. Provide roof framing plan' and floor framing
plan. Section 302 (d).
l0. Provide framing sections through
Section 302 (d).
li. Specify all header sizes for opening -over 4'
I wide. Section 2517 (g) 5.
l2. Provide calculations for main vertical and I horizontal framing members and post footings.
Section 302(b).
T..Provide calculations for lateral loads, shear
panels shear transfer and related. Section
302 (b5.
14. In Seismic Zones 3 and 4, the allowable shear
/ wall values for drywall in Table 47-I must be
reduced 50 percent when .considering earthquake
-•loads.- -This- does-not -appI-y- to -wind loads.-
Footnote • :
1j5. Show on the plans all structural requirements' / developed in the structural calculations.
Section 302 (d). (See comments below or at
end.)
16. Columns and posts located on concrete or
/ masonry floors or decks exposed to the weather
or -to water splash or in basements and which
support permanent structures shall be
supported by concrete piers or metal pedestals
projecting above floors unless approved wood
of natural resistance to decay or treated wood
is used. Section 2516 (c) 4.
iji. Individual concrete or masonry piers shall
I project at least 8 inches above exposed ground
unless the columns or posts which' they support
are of approved wood of natural resistance to
decay or treated wood is used.
Section 2516 (c) 4.
12'S. Show location of attic access with minimum
/ size 22" x 30". Section 3205.
I9. Show draft separation for attic areas between
units in a duplex. Section 2516 (f).
l0. Specify plywood and/or particle board
thickness, grade and panel identification
index. Table 25-S.
11. When roof pitch is less than 3:12, design
I ridge as a beam. Section 2517 (h).
4
2. If foundation cripple wall studs are less than
I 14" high, framing shall be solid blocking, or
sheathed with plywood. Section 2517 (g) 4.
l3. Cripple wall' studs exceeding 4 feet in height
shall be 3 inch by 4 inch or 2 inches by 6
inches when supporting 2 stories.
Section 2517 (g)4.
14 . Show plywood sheathing over exposed eaves, or
other weather exposed areas, is "bonded with
exterior glue." Plywood used for exterior
wall covering shall be the exterior type.
Section 2516 (i), 2516(g)3.
Detail truss layout for 30" x 30" attic
access, if required for equipment in the attic
and detail 30" x 30" clearance through truss
Ridges, hips, and valleys shall be at least
one size larger than supported rafters.
Section 2517 (h) 3.
17. In open beam construction, provide strap ties
/ across the beams at the ridge support.
Section 2501 (b).
7/5/91 ' 8
Note on the plans that "all weather-exposed
..} surfaces shall have a weather-resistive barrier
to protect the interior wall covering and that
exterior openings'5ha11 be flashed in such a
manner as to make them weatherproof". Section
1707.
!3AN1 (uNIF04 HEAN1CAL DE)
All heating, ventilating, and cooling systems and
appliances shall comply with the Uniform Mechanical
Code.
Show the size, location and type of all heating
—' and cooling appliances or systems.
.'17p /77 .1J /7L17471J7
ido. Every dwelling unit shall be provided with
/ heating facilities capable of maintaining a
room temperature of 70 degrees F. at 3 feet
above the floor in all habitable rooms•. Show
basis for compliance. JBC, Sec. 1212.
Note on the plans that the FAU closet or alcove
must be 12 inches wider than the furnace or
furnaces being installed. UMC Section 704.
Show minimum 30" deep unobstructed working
I space in front of furnace. Section 505, UIC.
Furnace shall not be installed in any bedroom,
bathroom or in a closet or confined space with
access only through such room unless specified
as direct vent appliance, enclosed furnace or
electric heating appliance.
Section 704 .UMC. -
Show source of combustion airto furnace, per I chapter 6, .UMC.
iL/S. Show access to the attic containing equipment
to be minimum 30 inches• by 30 inches. The
opening may be 22 inches by 30 inches if the
equipment can be removed through such opening.
Section 708 UMC.
1j6. Note that passageway to the attic furnae shall
I be unobstructed and have continuous solid
flooring not less than 24 inches wide, not more
than 20 feet in length through the attic.
"Section 708 UMC.
]7. Show permanent electrical outlet and lighting
/ fixture controlled by. a switch for furnace
located in attic or underfloor space. "Section
708 & 109 UMC.
iI's. Show details to comply with Section 709 for
furnace under the floor, or Section 710 for
roof or outside furnace. -
119. Show I.C.B.0. approval number for prefab
f fireplace. Show height of chimney above roof
per I.C.B.0. approval or Table 37-B.
l0. Note on plan: Gas vents and non-combustible
piping, in walls, passing through three floors
or less shall be effectively draft stopped at
each floor or ceiling.
UBC, Section 1706 (a) 6.
14. Provide dryer vent to outside. UMC, Section
/ 1903.
1ICAL (NATIONAL ELLRICAL CODE1
All wiring shall comply with the National
Electrical Code.
l2. Show on the plan the amperage of the
I electrical service, the location of the
service panel and the location of any sub-
panels. If service is over 200 amps, submit
single line diagram, panel schedule and load
calculations.
153 Note on the plans: "Electrical outlets shall
be installed in accordance with NEC Article
210-52".
Note on the plans: "Lighting outlets
controlled by a wall switch shall be provided
in accordance with NEC Article 210-70".
15S. Note on the plans: "Light fixtures installed
/ in clothes closets will comply with NEC
Article 410-811 .
16- Note convenience outlets in bathrooms, kitchen
counter top(s) within 6 feet of the kitchen
sink, outdoors, and in garages and basements
(other than for laundry and similar equipment)
shall be GFI protected. NEC, Art. 210-8.
I57. Note electrical system ground to be provided
I per NEC, Art. 250-80(a), 81(c).
PUJKBIIG (UN1704 PLUMBING CODE)
15kb. Show water heater size, type and location on
/ plans"." UPC, SetI6ii"130I7""
)9. Show source for providing combustion air to I fuel burning water heater. If wail openings
in an enclosure are.used, at least one-half of
the required opening area shall extend into
the upper twelve inches of the enclosure and
one-half within the lower twelve inches. UPC,
Section 1307.
7/9/91 - - . .. 9
A0. Fuel combustion water heater shall not be
installed in bath or bedroom or in a closet
opening into bath or bedroom. UPC, Section
1309.
16L Provide adequate barrier to protect •water / heater from vehicle damage. An 18" platform
for the water heater does not satisfy this
requirement. UPC, Section 1310.
142. Show T and P valve on water heater and show
route of discharge line to exterior.
I UPC, Section 1007 (e).
l(3. Show that water heater is adequately braced to
1 resist seismic forces, when not connected by
rigid pipe. UMC Section 504(d).
Show shower stall can accommodate a 30" circle I and has a minimum floor area of 1,024 sq. in.
UPC 909 (d).
15. Provide clothes washer hook-up for each unit. I Title 24, Part 3.
NOISE INSULATION (DUPLEXES)
1616. Show details of duplex common (party) walls and
/ floor/ceiling assemblies to achieve a Sound
Transmission Class (SIC) rating in walls of 50
decibels and an Impact Insulation Class (IIC)
rating on floor/ceiling of 50 decibels.
Title 24.
1d7. Show how penetrations of assemblies for piping,
/ electrical devices, recessed cabinets,
I bathtubs, soffits, or heating ventilating, or
exhaust ducts shall be sealed, lined, or
insulated to maintain required sound
transmission rating. Title 24.
148. Provide insulation in walls and ceiling to
achieve SIC of 50 between garage and living
area if garage use is not controlled by
resident. Title 24.
-. -.-- - -.,ENERGY QNSVAIION
p169. Provide plans, calculations: and worksheets to
show compliance with current energy standards.
170 The regulations require a properly completed and properly signed Form CF-1R to be either
imprinted on the plans, taped to the plans or
"sticky backed" on the plans, to allow the
building inspector to readily compare the
actual construction with the requirements of
the approved energy design.
171 All energy items shown on the plans must be in
agreement with -the information shown on the
properly completed Form CF-1R.
Specify on the building plans all of the \1 mandatory energy conservation requirements as
listed on the enclosure titled, "Mandatory
Energy - Conservation Requirements".
173 Show the make, model and efficiency of the
space heating (or cooling) system and provide
heat loss calculations if the output exceeds
45,000 BTU/Hr.
C174) For room additions, show that the glazing area
of the addition does not exceed 16% of the
newly-conditioned floor area, plus glazing
removed or relocated due to the addition.
l?S. Provide fluorescent general lighting in / kitchen(s) per CAC, Title 24, 2-5352(3).
CARLSBAD S .F.D. & DUPLEX SUPPLEMENT
176. Energy conservation design should be for Zone
7.
17j7. Floor drains must have auto-prime (city
policy).
178. For gas piping under slabs that serve kitchen
/ island cooktops, see the attached Policy 91-46
for special sleeve and clean-out requirements.
19. Note exhaust fans cannot be ductless type
/ (city policy).
186. New residential units must be pre-plumbed for
future solar water heating. Note "two roof
jacks must be installed" where the water
heater is in the one story garage and directly
below the most south facing roof (City
Ordinance No. 8093).
181. Note "two 3/4" copper pipes must be installed
to the most convenient future solar panel
location when the water heater is not in a one
story garage and is not directly below the
most south facing roof. (City Ordinance No.
8093).
$. All piping for present or future solar water
/ heating must be insulated when in areas that .
are not heated or cooled by mechanical means
(city policy).
18)3. Incorporate the waterproofing details, on the
/ attached Policy 80-8, where interior living
space occurs below grade at the masonry
wall(s).
4. Show on the Title Sheet on the plans, the
information required by the attached
Developmental Services Sheet 112383.
7/10/91 10
All new residential buildings, including
\/ additions, require a soils report. Please
submit two copies. Exception: If a room
addition is limited to one story and 1000 sq.
ft. in area, then a soils report is not
required. Esgil Corporation will advise the
City to place their soils notice stamp 'on the
plans.
Heavy timber framing, minimum 6" x 10" beams
and minimum 8" x 8" post, for the structural
beam and column supporting the fire separation
between the garage and living area above, is
acceptable if shown on the plans.' (city'
policy).
All structures reqüire.a Class 'B roof'covering, ( except room additions. If a room addition
covers all of the existing building (2nd story
addition), then the above exception doesn't
apply.
i4. City Ordinance 9792 requires two parking / spaces/unit with clear area of 20'x20' i.e. no
washing machines, etc. Show compliance.
The City of Carlsbad has contracted with Esgil
Corporation located at 9320 Chesapeake Drive, Suite
208, San Diego, California 92123; telephone number
619/560-1468, to perform the plan check for your
project. If you have any questions regarding these
plan check items, please contact___________________
~ AuEf- I'4
at Esgil Corporation. If you have any questions
regarding City 'Building permit procedures, please
contact Carter Darnell at the City of Carlsbad,
2075 Las Palmas Dr., telephone 619/438-1161.
Thank you.
Enclosures:
2.
19. All chimneys attached th any appliance or
fireplace that , burns solid fuel shall be
equipped with an approved spark arrester. The
net free area of the spark arrester shall be
not less than four times the net free ara of
the outlet of the chimney. The spark arrester
screen shall have heat and corrosion resistance
equivalent to 12 gauge wire, 19 gauge
galvanized wire or 24 gauge stainless steel.
Openings shall not permit the passage of
spheres having a diameter larger than 1/2-inch
and shall not block the passage of spheres
having a diameter of less than 3/8-inch.
3.
MISCELLANEOUS
5 0
Please see additional corrections, or remarks,
on the following, page.
191 To speed up the recheck process, note on this
list (or a copy).. where.eachcorrection item has
been addessed, 1'.e., plansheet, dofe7 or
detail number, calculation page, etc.
192. Please indicate here if any changes have been
made to the plans' that are not a result of
corrections from this list. If there are other
changes, please briefly describe them and where
they are located in the plans.
Have changes been made to the plans not
resulting from this correction list? Please
check.
_____Yes No
7/10/91 . 11
Date JurisdictionCARLSBAD
Prepared by
cy17 AWL. yy VALUATION AND PLAN CHECK FEE
Bldg. Dept.
Esgil
PLAN CHECK NO.
BUILDING ADDRESS
APPLI CAN T/CON TACT • 71//&i PHONE NO.
BUILDING OCCUPANCY. DESIGNER PHONE_____________
TYPE OF CONSTRUCTION IJ CONTRACTOR PHONE
BUILDING PORTION BUILDING AREA VALUATION
1ULTIPLIER
VALUE
73 377
_____________•1 ____ _______
Air _Condjtionjn:
Commercial
- Residential
Res. or Comm.
Fire _Sprinklers
Total Value
7g7
Building Permit Fee $ $
12,
Plan Check Fee $ S
COMMENTS:
SHEET OF_____ 12/87
BUILDING PLANCHECK
\ ENGINEERING CHECKLIST
DATE: IU 4-1 ITEM COMPLETE
PLANCHECK NO. 01 1' 17?--P,4- ITEM INCOMPLETE
NEEDS YOUR ACTION
* ) 2.. 3 ° K r I\Q. ITEM SELECTED
D (sig
ET V A LV E I,- I * • -' C C C PROJECT ID: l(I(121.1--L)3 15'h
E E E LEGALREQUIREMENTS
SitePlan
1. Provide a fully dimensioned site plan drawn to scale.
Show: north arrow, _property lines, easements, existing and
proposed structures, Ffr-55Ts, .gxistfn-g streef improvements,
right-of-way width and dimension
Show on site plan: Finish floor elevations, pad
elevations, elevations of finish grade adjacentto
buildi, pq existing topográh Ilines, exiifihg and
:1 4.t.#
Provide le al description and Assessors Parcel Number.
AY q o&
Discretionary _Approval Compliance
No Discretionary approvals were required.
LIEE 5. Project complies 'with all Engineering Conditions of
Approval for Project No.________________
Project does not comply with the following Engineering
Conditions of Approval for Project No.___________________
Conditions complied with by:Date:
FieldReview
E E El 7 . Field review completed. No issues raised.
8. Field review completed. The following issues or
discrepancies with the site plan were found:
Site lacks adequate public improvements
Existing drainage improvements not shown or in
conflict with site plan.
Site is served by overhead power lines.
P:\D0CS\MISF0RMS\FRM0010.DH • REV. 02/27/91
Grading is required to access site, create pad or
provide for ultimate street improvement.
EL11 E.
DEE F.
Site access visibility problems exist. Provide onsite
turnaround or engineered solution to problem.
Other:
Dedication Requirements
9. No dedication required.
D E E 10. Dedication required. Please have a registered Civil
Engineer or Land Surveyor prepare the appropriate legal
description together with an 8½" x 11" plat map and submit
with a title report and the required processing fee. All
easement documents must be approved and signed by owner(s)
prior to issuance of Building Permit. The description of
the dedication is as follows:___________________________
Dedication completed, Date By:
Improvement Requirements
E OF] 11. No public improvements required. SPECIAL NOTE: Damaged or
defective improvements found adlacent to building site must
be repaired to the satisfaction of the City inspector prior
to occupancy.
E E E12 Public improvements required. This project requires
construction of public improvements pursuant to Section
18.40 of the City Code. Please have a registered Civil
Engineer prepare appropriate improvement plans and submit
for separate plancheck process through the Engineering
Department. Improvement plans must be approved,
Appropriate securities posted and fees paid prior to
issuance of permit. The required improvements are:_______
Improvement plans signed, Date: by:
P:\D0CS\MISF0RMS\FRM0010.DH REV. 02/27/91
13. Improvements are required. Construction of the public
improvements may be deferred in accordance with Section
18.40 of the City Code. Please submit a letter requsting
deferral of the required improvements together with a
recent title report on the property and the appropriate
processing fee so we may prepare the necessary Future
Improvement Agreement. The Future Improvement Agreement
must be signed, notarized and approved by the City prior to
issuance of a Building Permit.
Future Improvement Agreement completed, Date:____________
By:.
LII E E 13a. Inadequate information available on site plan to make a
determination on grading requirements. Please provide more
detailed proposed and existing elevations and contours.
Include accurate estimates of the grading quantities (cut,
fill, import, export).
E 14. No grading required as determined by the information
provided on the site plan.
E E 15. Grading Permit required. A separate grading plan prepared
by a registered Civil Engineer must be submitted for
separate plan check and approval through the Engineering
Department. NOTE: The Grading Permit must be issued and
grading substantially complete and found acceptable to the
City Inspector prior to issuance of Building Permits.
Grading inspector sign off. Date: by:_________
Miscellaneous Permits
El El 16. Right-of-way Permit not required.
17. Right-of-Way Permit required. A separate Right-of-Way
Permit issued by the Engineering Department is required for
the following:
'EJ 18.
19.
Sewer Permit is not required.
Sewer Permit is required. A sewer Permit is required
concurrent with Building Permit issuance. The fee required
is noted below in the fees section.
Industrial Waste Permit is not required.
P:\D0CS\MISF0RMS\FRM0010.DH • • REV. 02/27/91
E El El 21. Industrial Waste Permit is required. Applicant must
complete Industrial Waste Permit Application Form and
submit for City approval prior to issuance of a Building
Permits. Permits must be issued prior to occupancy.
Industrial Waster Permit accepted -
Date: By:
Fees Required
El 27. Park-in-Lieu Fee
Quadrant: Fee per Unit:_____________
Total Fees:_____
O Traffic Impact Fee
Fee Per Unit: Total Fee:__________
E] Bridge and Thorough fare Fee
• Fee Per Unit: Total Fee:__________
El Public Facilities Fee required.
E] Facilities Management Fee Zone: Fee:________
O Sewer Fees Permit No. EDU's_______
- Benefit Area:-Fee:
o Sewer Lateral Required:
Fee:_______________
29. REMARKS: SEE JE M 1 3 FO
G(J li25-I
c'y (ca Co) c5P PF'IcOuS
siJt
ENGINEERING AUTHORIZATION TO ISSUE PERMIT
DATE ///4('
P:\DOCSV4ISFORMS\FRMOO1O.DH
•
REV. 02/27/91
PLANNING CHECKLIST
Plan Check No. 9/ /27/Address I 23J7 hf)oJks Ave
Planner Da v' ck Phone 4384161 ext. /_J3 Z 27
(Name)
APN: )6— Ic9 5L1
Type of Project and Use 4-/
Zone R —) Facilities Management Zone
U Legend
U 0 4) 4) .c .0 U U
C C to (U
Item Complete
Item Incomplete - Needs your action
1, 2, 3 Number in circle indicates plancheck number where deficiency was
identified
Environmental Review Required: YES - NO .7iE._______
DATE OF COMPLETION:
Compliance 'with conditions of approval? If not, state conditions which require action.
- Conditions of Approval
Discretionary Action Required: YES NO E
APPROVAL/RESO. NO. DATE:
PROJECT NO.,
OTHER RELATED CASES:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval
California Coastal Commission Permit Required: YES - NO -
DATE OF APPROVAL:
San Diego Coast District, 3111 Camino, Del Rio South, Suite 200, San Diego, CA. 92108-1725
(619) 521-8036
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval
ndscape Plan Required: S NO
See attached submittal requirements for landscape. plans
Site Plan:
Provide a ally dimensioned site plan drawn to scale. Show:
arro, property Lines, easements, existing and proposed structures,
streets, existing street improvements, right-of-way width ar
dimensioned setbacks.
Show on Site Plan: Fsh floor elevations, elevations of tish lgade
adjacent to building, existing topographical lines, existing and pr000sed
slopes and driveway.
'Provide legal description of property.
Provide assessor's parcel number.
Zoning:
I. Setbacks:
?c Shown 2'
Y s" Shown lo'
it4pr Shown 4i4
/f.''Shown 5/
40/Shown
Shown 14"
£/ Shown
Shown
Front: . Required
Ent.ide: Required
Street Side: Required
Rear: Required
Lot coverage: Required
Height: Required
4 Parking: Spaces Required
Guest Spaces Required
0 0 0 Additional Comments
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE
PLNCK. FRM
7 CERTIFICATION OF COMPLIANCE
CITY OF CARLSBAD Plan Check No.
DEVELOPMENT PROCESSING SERVICES DIVISION
2075 LAS PALMAS DR., CARLSBAD, CA 92009
(619) 438-1161
This form shall be used to determine the amount of school fees for a project and to verify
that the project applicant has complied with the school fee requirements. No building
permits for the projects shall be issued until the certification is signed by the appropriate
- school district and returned to the City of Carlsbad Building Department.
SCHOOL DISTRICT:
sbad Unified
801 Pine Avenue
Carlsbad, CA 92009 (434-0610)
Encinitas Union.
101 South Rancho Santa Fe Rd.
Encinitas, CA.. 92024 (619) 944-4300L
San Marcos Unified
1290 West San Marcos Blvd.
San Marcos, CA 92024 (744-4776)
San Dieguito Union High School
710 Encinitas Boulevard
Encinitas, CA 92024 (753-6491)
Project Applicant: co1 -_-JC/ APN:/-7-5'
Project Address: ,-'t'
\RESIDENTIAL: SQ. FT. of Ili ving area__ number of dwelling units___________
SQ. FT. of covered area SQ. FT. of garage area_____________
COMMERCIAL/INDU RIAL: SQ. . AREA______
Prepared by
.,
Date
-------------------------------------------------------------------------------------------
FEE CERTIFICATION
(To be completed by the School District)
V"Applicant has complied with fee requirement under Government Code 53080
Project is subject to an existing fee agreement
Project is exempt from Government Code 53080
Final Map approval and construction started before September 1, 1986.
(other school fees paid) -
Other .
Residential Fee Levied: $ based on '\\ - sq. ft. @ ..
Comm/Indust Fee Levied:$ based on sq. ft. @________________
cia Date
AB 2926 and SB 201 fees are capped at $1.58 per square foot for residential.
AB 2926 is capped at .26 per square foot for commercial /industrial.
BUI LD I N G PERMIT PCR No: PCR92012
02/21/92 09:55 Project No: A9101610
Page 1 of 1 Development Nb:
Job Address: 1239 KNOWLES AV Str: Fl: Ste:
Permit Type: PLAN CHECK REVISION 6469 02/21/92 0001 01 02
Parcel No: 156-164-54-00 CPRMT 5400
Valuation: 0
Construction Type: NEW Q / ,'7 Occupancy Group: Class Code: Status: ISSUED'
Description: FOUNDATION WALL Applied: 02/07/92
Apr/Issue: 02/21/92
Validated By: SBB
Appl/Ownr : COPELAND, STEPHEN (619)729-1065
1239 KNOWLES AV
CARLSBAD, CA 920
CreditsFees Required d -
14
Fees: 54.0 c? ( \
Adjustments: / ç\00 To .00
Total Fees: f 54. 0.0 ToL Pa.. meS: .00
/ Balan \ ': 54.00
Fee description f F ecU i Ext fee Data
Plan Check Revisio 1fe 54.00
INCORPORATED
1952
4)
FINAL APPROVAL
INSP.. DATE ______
CLEARANCE
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
''1 foiSrc - /d 0,?.'--r
IJFTk/649 TT
-q PFc3qR
a W77
a
REV1.SI6\3 Of F 3Tjd, L1-)
13t-oedk
oJ-,o
H
II &k— -10ic
/3 IV b
I2")l O,7--06fl&)
.3"
'3,,
'I
1hiu (1DEtAA)
tL IL.
- l2kV
AOL
frLSe7, e,i.
kz #.
ESGIL CORPORATION
- 9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: Z/1/T2 ______________________________________ (]APPLICANT
JURISDICTION:
Ii2 SET:
COPY
PLAN CHECK NO: EUPS
ÜDESIGNER
PROJECT ADDRESS:iZ?7
PROJECT NAME:
E The, plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
'with the jurisdiction's building codes' when minor deficien-
des identified Eii'&iQKS EELIILAJ are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies D
identified on the enclosed check list and should be corrected
and resubmitted for acomp1'ete recheck.
1-,The-check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.-
fl The
applicant's copy of the check list is enclosed for the
jurisdiction to return 'to the applicant'contact person..
The applicant's copy of the check list has been sent to:
Esgil staff did, not advise the applicant contact person that
plan check has been completed.
fl Esgil staff did advise applicant that the plan'check has
- been completed. Person contacted:
Date contacted: Telephone #
IEEq
________________
:REMARKS:() )IL47/"J4 1'EJ', 7 VJF ) 77-17 /rL F&77A4
I 'J t2Y i J7Z Fl tJPc7lJ C,v7f4C7Et' //LL,
(2) Ic±r OF FJiipfrrWii a9ifri /JOT E>(CLD ZF7.
By: $y
' -
Enclosures:
ESGIL CORPORATION
LGA M
Date s 1_/I7 Jurisdiction -
Prepared bys Bldg. Dept.
$yep /416c2)j VALUATION AND PLAN CHECK FEE E3 Esgil
PLAN CHECK NO.
BUILDING ADDRESS -
l2_7 J&41JL&.S
APPLICANT/CONTACT PHONE NO._________________
BUILDING OCCUPANCY i - 3 DESIGNER PHONE____________
TYPE OF CONSTRUCTION CONTRACTOR PHONE_________
BUILDING PORTION BUILDING AREA VALUATION
MULTIPLIER
VALUE
Air CondjtioninE
Commercial
Residential
Res. or Comm.
Fire _Sprinklers
Total Value
Building Permit Fee $
Plan Check Fee $ $
COMMENTS; 65:5
- : SHEET OF_____ 12/87