Loading...
HomeMy WebLinkAbout1243 MARIPOSA RD; ; CB050427; Permit----------· ✓ \LG\ City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 03-07-2005 Electrical Permit Permit No: CB050427 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Reference #: 1243 MARIPOSA RD CBAD ELEC 2122203900 Project Title: //--~ffiDE CE /·:;::?~~--. R~ MOUNT P SYSTEM ~pplicant: CLEAN POWER SYSTEMS INC. STE 205 9948 HIBERT ST SAN DI Electric Issue Fee Single Phase per AMP Three Phase per AMP Three Phase 480 Per AMP Remodel/Alteration per AMP Remodel Fee Temporary Service Fee Test Meter Fee Other Electrical Fees Additional Fees TOTAL PERMIT FEES Status: Lot#: 0 Applied: 0 0 0 0 Entered By: Plan Approved: Issued: Inspect Area: Owner: WILKE MARK W&NEILSON LORNA I 1243 MARIPOSA RD CARLSBAD CA 92009 ISSUED 02/11/2005 MDP 03/07/2005 03/07/2005 $10.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $110.00 $0.00 $120.00 Total Fees: $120.00 Total Payments To Date: $0.00 Balance Due: $120.00 3201 03/07/05 0002. O.l CGP Inspector: Date: Clearance: NOTICE: Please take NOTIC hat approval of your project includes the "Im sition" of ees, dedications, reseivations, or other exactions hereafter collectively referred to as "fees/exactions.ff You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. lf you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOA DOES IT APPLY to any i n fwhi h v i iv n N Tl i r h f. 02 120. oo PERMIT APPLICATION FOR OFFICE USE ONLY PLAN CHECK NO.c:::6-. <-t t.. 7 CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 EST. VAL. _________ _ Plan Ck. Deposit ________ _ Validated By ___ -_--1''--"7'--- Date. ___ ..._2_~/,_,f,_.L.,_..,{,-""0~}--~1, >,;)!}'!45FO;m\~¢id-,14 ·. ··~ Address (include Bldg/Suite #) Business Name (at this address) Legat Description lot No. Subdivision Name/Number Unit No. Phase No. Total # of units Proposed Use # of Bedrooms # of Bathrooms Name Address City ~t, i/,r~~cANt.:, ::C}:'CQOti'.~~tQr/ ;i!-[li)~.g~ii,'(fo,i:'P1>11iraior, ·.: CrOwrie(: ''[QL;"gem for Own·er Name Address City State/Zip Telephone# Fax# State/Zip Telephone# + 1n'~~;z·m1~E:.., · ... tz:4-~mJlfeiP@l'f fu 4rll~W. c-A '9&Pi '//4-4~,- Name Address City State/Zip T elephone # .... 7 &/::?Z..- State License # ---<8.L--=Z=_.7_,_/~~c...,-<._ License Class --~c=c.it.=~='------City Business License # Designer Name Address City State/Zip State License # _________ _ :6:•;:,,wolli¢~~Sf0iiibMH!ISAtlliNi;,;•• ,. Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 l have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance he work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which thi permit is ss ed. My worker's compensat n ~urance carrier and~ 'I{ number are: <::;" Insurance Companyy~!J!ZL!tl!!",.\,1/.(..;:~ , S~o Policy No. tC}c)")-<:2:1255t?"L Expiration Date ~ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS {$1001 OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), In addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, Interest and attorney's fees. :;~.~:;~"'II'". t11.111;;;;\on .. ~.i .. ~j<;fffl'Ei<·c~-/lil"i••;;.:i;:t,;;;li;;;N;;:i,;,.;.:--;-;-:;;:;-:-::-:-;:;:;;:;:;:;-:-;:;:;;:;:;;:;:;:--;-:--;-:--;-;:;:;;:;:;-:--;--:-: DATE--------- 1 hereby affirm that I am exempt from the Contractor's License law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 l, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License law). 0 I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the ma.jor labor and materials for construction of the proposed property improvement. D YES ONO 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. 1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone number/ contractors license number): ________________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) .. ·_----------------------------------------------------------- PROPERTY OWNER SIGNATURE ______________________ _ DATE _________ _ 'C:OM~IJ!Ti!,'111is:stct!oll FOIi· N'Oll<iliml!EJl'ffAL'li!)[Coi~•peRMIN Ci!l~V• •• Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO ls the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES O NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. J,:;i1i!Illlllll!f!l!JQ'!iliN1LENl>!NQ1/l.ll~N(t)'.,·•••,•• I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 30970) Civil Code}. LENDER'S NAME .,,..-==:c:c-cc::::c-----,:-,-=::c::--c- '9,k ,, ll.l!i'iJ!l~ij:rc;:i;ljti~illi\l'!PN•n I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work. authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by sue per it is suspended or abandoned ·~ at any time after thew for a 10d f O days (Section 106.4.4 Uniform Building Code). l°'APPLICANT'S SIGNATURE DATE _:::C-J--'1.--J:::C~.,L----- WHITE: File YELLOW: Applicant PINK: Finance m. City of Carlsbad Bldg Inspection Request . . . Permit# CB050427 For: 03/24/2005 Title: WILKE RESIDENCE Description: ROOF MOUNT P V SYSTEM Type: ELEC Sub Type: Job Address: 1243 MARIPOSA RD Suite: Lot 0 Location: OWNER WILKE MARK W&NEILSON LORNA I Owner: WILKE MARK W&NEILSON LORNA I Remarks: Total Time: ----- Inspector Assignment: ~ Phone: 6198432771 Inspector: ~ Requested By: TIM CD Description Entered By: CHRISTINE ~mment ~~fl~~"""'-"'=c::-~rf{)~--=S___,,D::.....,'1.._,C:: ___ _._p__,___,,. ti 8.J-S2~ 39 Final Electrical Associated PCRs/CVs Inspection History Date Description Act lnsp Comments DATE: 3/7/05 JURISDICTION: Carlsbad PLAN CHECK NO.: 05-427 EsGil Corporation In <Partnersnip witn government for (JJui{aing Safety SET: III PROJECT ADDRESS: 1243 Mariposa Road PROJECT NAME: Residential 6000 Solar Photovoltaic □ APPLICANT □ JURIS. □ PLAN REVIEWER □ FILE [8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: 858 693-3434 Date contacted: (by: ) Fax #: No fax listed Mail Telephone Fax In Person [8J REMARKS: Applicant hand carrying plans back to the City. By: Eric Jensen Esgil Corporation □ GA □ MB □ EJ □ PC Enclosures: otc/3/7 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: 2/22/05 JURISDICTION: Carlsbad PLAN CHECK NO.: 05-427 EsGil Corporation In <Partners nip witn (jo11ernment for <Buifaing Safety SET:I PROJECT ADDRESS: 1243 Mariposa Road PROJECT NAME: Residential 6000 Solar Photovoltaic □~NT ~- □ PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Clean Power Systems 9948 Hibert Street Suite 205 San Diego 92131 0 Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: (--.. f-1.) Telephone#: 858 693-3434 Date contacted: J..f 2.'.':,/os (by: -) Fax #: No fax listed Mail c....-Telephone ✓ Fax In Person 0 REMARKS: By: Eric Jensen Esgil Corporation D GA D MB D EJ D PC Enclosures: 2/15 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad 05-427 2/22/05· GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 1243 Mariposa Road DATE PLAN RECEIVED BY ESGIL CORPORATION: 2/15 REVIEWED BY: Eric Jensen FOREWORD (PLEASE READ): PLAN CHECK NO.: 05-427 DATE REVIEW COMPLETED: 2/22/05 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections on the originals and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? □ Yes D No Carlsbad 05-427 2/'1,2/05 · ELECTRICAL CORRECTIONS PLAN REVIEWER: Eric Jensen ELECTRICAL (1999 NATIONAL ELECTRICAL CODE) 1. Include the following information on the single line diagram: ❖ The (module) series rated fuse protection on the DC high voltage side of the inverter (and) ❖ The positive connection required at the service panel overcurrent device (NEC 384- 16(9)). (and) ❖ A description of the signage required by NEC 690-17: Include verbage and locations. (and) ❖ Provide documentation of the GFCI protection as afforded by the SunnyBoy 6000. NEC 690-5. Note: If you have any questions regarding this Electrical plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad 05-427 2/'!,2_/0.5 . !VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 05-427 PREPARED BY: Eric Jensen DATE: 2/22/05 BUILDING ADDRESS: 1243 Mariposa Road BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING AREA Valuation Reg. VALUE ($) PORTION ( Sq. Ft.) Multiplier Mod. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code OS 91 1994 UBC Building Permit Fee 1994 UBC Plan Check Fee • i Type of Review: 0 Complete Review D Structural Only D Repetitive Fee · .;:] Repeats D Other 0 Hourly 1 j Hour• Esgll Plan Review Fee $96.ooj • Based on hourly rate Comments: Sheet 1 of 1 macvalue.doc ... PLANNING/ENCINEERINC APPROVALS · .. ·. ·• .. PERMIT NUMBER CB ~ ·'3--l/ 2 7 G-) RESIDENTIAL ADDITION MINOR f < $10,000.00) DATE __ 2,.,,,_/_/'-I....J./_~_;:_r_·_ TENANT IMPROVEMENT PUIZA CAMINO REAL CARLSBAD COMPANY STORES . VILLACE' FAIRE COMPLETE OFFICE BUILDING OTHER ___________ ....:...._ ______ _ PLANNER ____ ·_,_~...11:·~...,__ __ _ · DATE __ 2.-1-/..!....! _,_V /:.-:~~S:-. ENGINEER --------DATE -------