Loading...
HomeMy WebLinkAbout1245 BELLEFLOWER RD; ; CB971193; Permit*_- '' &pek3l5s&5 €3 U I L D I N G P E R M I T Permit No: CB971193 OJ 1/92 lf:47 Project No: A9701556 Page 1 of 1 Development No: DEV92002 Job Address: 1245 BELLEFLOWER RD Suite: Permit Type: SINGLE FAMILY DWLNG - DETACHED Parcel No: 214-542-02-00 Lot#: 38 Occupancy Group: Reference#: CT 92-02 Status: ISSUED Description: PLAN 3,PHS 1,3206+665 GAR+93SF Applied: 04/07/97 : PORCH+123 DECK,SAMBI SEASIDE-KAUFMAN Apr/Issue: 05/21/97 1 Valuation: 265,326 Construction Type: VN Entered By: RMA Appl/Ownr : KAUFMAN L BROAD 619 259-6000 9162 os/a/sr7 O001. 01. 02 12626 HIGH BLUFF STE 400 SAN DIEGO CA 92130 C-KHT 1603 u 80 Plan Check Numbers > ORIG 970369 PCK 970792 *** Fees Required *** *** Fees Collected & Credits *** ____----------__------------ ............................................ Fees : 16,379.80 Adjustments: .oo 1 Total Fees: 16,379.8. Fee description .__-_-_--_--------_--- Number of Bedrooms Number of Bathrooms Building Permit Plan Check Strong Motion Fee or Enter Park-in-I Enter "Y" to Autocc Enter "Y" to Autocc CFD Fees Waived(W)< Payoff Fee for CFD * BUILDING TOTAL Enter #Units & Code- Enter "Y" for Plumbi Each Plumbing Fixtur Each Building Sewe Each Install/Repair Water Each Water Heater and/or Vent- Gas Piping System .oo 350.00 16,029.80 Ext fee Data 5.00 3.00 1221.00 794.00 27.. 00 1575.00 3 4829.00 Y 540.00 Y N ______-_-------- 4670.80 13656.80 2400.00 D5/8 20.00 Y 112.00 15.00 7.00 7.00 7.00 Each Vacuum Breaker > 2 7.00 14.00 * PLUMBING TOTAL 182.00 Enter "Y" for Electric Issue Fee > 10.oa Y 50. OD * ELECTRICAL TOTAL 60.00 Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts/Heat Pumps Each Install Fireplace Each Exhaust Fan Each Install/Reloc Vent * MECHANICAL TOTAL Single Phase Per AMP > 200 .25 CllY OF CARLSBAD 2075 Las pahnas Dr., carlsb9d, CA 92009 (619) 438-1161 FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING CMWD PLAN CHECK#: CB971193 DATE : PERMIT#: CB971193 PERMIT PROJECT NAME: PLAN 3,PHS 1,3206+665 GAR+93SF PORCH+123 DECK,SAMBI SEASIDE-KAUFMAN ADDRESS: 1245 BELLEFLOWER RD Lot# 3Oqf ONE#: C/HAROLD/929-1008 1 WATER DIST: CA 10/14/97 TYPE: SFD INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING CMWD WATER. PL?N CHECK#: CB971193 . DATE: 10/14/97 PERMIT#: CB971193 PERMIT TYPE:- PROJECT NAME: PLAN 3,PHS 1,3206+665 GAR+93SF PORCH+123 DECK,SAMBI SEASIDE-KAUFMAN ADDRESS: 1245 BELLEFLOWER RD Lot# 38 SFD CONTACT PERSON/PHONE#: C/HAROLD/929-1008 SEWER DIST: CA WATER DIST: CA INSPECTED DATE BY : INSPECTED: APPROVED - ..DISAPPROVED - INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - FINAL BUILDING INSPECTION AEPT: BUILDING ENGINEERING FIRE PLANNING CMWD WATER PLAN CHECK#: CB971193 PERMIT#: CB971193 PRQJECT NAME: PLAN 3,PHS 1,3206+665 GAR+93SF PORCH+123 DECK,SAMBI SEASIDE-KAUFMAN ADDRESS: 1245 BELLEFLOWER RD Lot# 38 CONTACT PERSON/PHONE#: C/HAFtOLD/929-1008 SEWER DIST: CA WATER DIST: CA DATE : PERMIT 1 O/ 14/9 7 TYPE: SFD INSPECTED DATE BY: INSPECTED : APPROVED - * DISAPPROVED - INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - FINAL BUILDING INSPECTION DEW: BUILDING ENGINEERING FIRE PLANNING CMWD WATER PLAN CHECK#: CB971193 PERMIT#: CB971193 PROJECT NAME: PLAN 3,PHS 1,3206+665 GAR+93SF ADDRESS: 1245 BELLEFLOWER RD Loti $8 PORCH+123 DECK,SAMBI SEASIDE-KAUFMAN DATE : PERMIT 10/14/97 TYPE: SFD INSPECTE~ DATE BY t INSPECTED : APPROVED I- DISAPPROVED I INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - FINAL BUILDING INSPECTION DEW: BUILDING ENGINEERING FIRE PLANNING CMWD WATER PLAN CHECK#: CB971193 PERMIT#: CB971193 PROJECT NAME: PLAN 3,PHS 1,3206+665 GAR+93SF PORCH+123 DECK, SAMBI SEASIDE-KAUFMAN DATE: 10/14/97 PERMIT TYPE: SFD I -- ADDRESS: 1245 BELLEFLOWER RD Lot# ps CONTACT PERSON/PHONE# : C/HAROLD/929-1008 SEWER DIST: CA WATER DIST: CA INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971193 FOR 10/24/97 DESCRIPTION: PLAN 3,PHS 1,3206+665 GAR+93SF PORCH+123 DECK, SAMBI SEASIDE-KAUFMAN TYPE: SFD JOB ADDRESS: 1245 BELLEFLOWER RD APPLICANT: KAUF" 61 BROAD CONTRACTOR: OWNER: REMARKS: C/HAROLD/929-1008 SPECIAL INSTRUCT: TOTAL TIME: CD LVL DESCRIPTION 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical INSPECTOR AREA PD PLANCK# ORIG 970 OCC GRP CONSTR. TYPE VN STE : LOT: 38 PHONE: 619 259-6000 INSPECT0 ACT COMMENTS M .. ***** INSPECTION HISTORY ***** DATE 101597 101497 091097 090897 090897 090597 090597 090497 090497 090397 090397 090297 090297 081997 081897 072997 072997 062697 062597 062497 061797 061797 061697 061697 061397 061397 061297 061197 DESCRIPTION Final Electrical Final Electrical Drywall/Ext Lath/Gas Test Rough Combo Insulation Exterior Lath/Drywall Rough Combo Rough Combo Exterior Lath/Drywa11 Exterior Lath/Drywall Rough Combo Exterior Lath/Drywall Rough Combo Roof Sheathing/Ext Shear Roof Sheathing/Ext Shear Shear Panels/HD's Roof/Reroof Ftg/Foundation/Piers Ftg/Foundation/Piers Ftg/Foundation/Piers Underground/Under Floor Sewer/Water Service Underground/Under Floor Sewer/Water Service Underground/Under Floor Sewer/Water Service Underground/Under Floor Underground/Under Floor ACT INSP COMMENTS AP PD CA PK RESET FOR 10-15-97 AP PD AP PD AP PD AP PD AP PD NR PD NR PD NS PD NS PD CO PD CO PD AP PD AP PD NR PD NR PD AP PY NR PY NR PY AP PD AP PD NR PD NR PD NR PD NR PD AP PD AP PD SOUTHERN CALIFORNIA SOIL AND TESTING, INC. 6280 RIVERDALE STREET, P. 0. Box 600627, SAN DIEGO, CA 92160 (619) 280-4321 Concrete Compressive Strength Test Report File Number: 971 21 87 Project Title: Collections Project Location: 1245 Belleflower Road Architect: Kaufman & Broad Permit No: 971 193 Engineer: JLD Plan File No: Contractor: Kaufman & Broad Location In Structure: Material Supplier: Superior Ready Mix Mix Designation: 35P Admixture(s): Time In Mixer (Minutes): 75 Slump, Inches: 3-1 12 CC Temp: 0 Truck Number: 386 Ticket Number: 2 16643 Air Temp: 0 Samples Fabricated By: KE Samples Tested By: JWB Air Content: Lot #38 - Slab-on-Grade x Laboratory Number: I Mark: 2 Date Made: Date Received Date Tested Diameter, Inches Area, Square inches Maximum Load, psi Compressive Strength, psi Age Tested, Days Required 28 Day Strength, psi Unit Weight, pcf 8567 06-26-97 06-27-97 07-07-97 6.00 28.27 85,500 3,020 11 2,500 8568 07-24-97 105,000 3,710 28 I Specimen sampling, transportation and compressive strength testing were performed by this agency in accordance with the applicable ASTM standards. This agency makes no other warranties express or implied. I Il Distribution: (3) Kaufman & Broad (1) Superior Ready Mix (1) City of Carlsbad Reviewed By: George *A Gavi , RCE #56564 06-26b 7/25/97 I DAILY FIELD ENGINEERING REPORT PACIFIC SOILS ENGINEEHNG, IN%. Client: k% i3 Work Order: &my ~r, Clients Representative: NwmD Tract No.: Date: b/as/ q7 Project Name: GU Day: H~-~ Contractor: Approximate Fill Yardage : > t Project Location: & Weather Conditions: b ~~~ Type and Number of Rigs in Operation: Description of Pro-ject Activities: Site Visitors / Firm: For Pacific Soils Engineering, Inc. Received by: Page -of - dafldrpt.sam SOU" CALIFORNLA SOIL & TESTING, Dice 6289 BIVERDALE STREET, P.O. BOX 698627 SAN MEGO, CI. %lie, Pbome (619) 280-4321 I I