HomeMy WebLinkAbout1265 LAUREL TREE LN; ; CB053648; Permit06-06-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB053648 Building Inspection Request Line'(760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 1265 LAUREL TREE LN CBAD Tl Sub Type: 2120402500 Lot#: $1,312,500.00 Construction Type: Reference #: 24 HOUR FITNESS 37500SF Tl FROM SHELL TO FITNESS CENTER COMM 0 V1 Applicant: NINA RAEY SUITE 3K 1342 BELL AVE 92780 714-258-1808 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check*: Owner: ASCENT BILTMORE CARLSBAD L L C 8475 E HARTFORD DR #201 SCOTTSDALEAZ 85255 ISSUED 10/21/2005 SB 06/06/2006 06/06/2006 Building Permit Add'l Building Permit Fee Plan Check AddTPIan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot, Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $3,713.94 Meter Size $0.00 Add'l Reel. Water Con. Fee $2,414.06 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee .$275.63 PFF (3105540) $0.00 PFF (4305540) $0.00 License Tax (3104193) $0.00 License Tax (4304193) $245,494.00 Traffic Impact Fee (3105541) $0.00 Traffic Impact Fee (4305541) $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Master Drainage Fee Sewer Fee $0.00 Redev Parking Fee $0.00 Additional Fees HMP Fee TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $23,887.50 $0.00 $0.00 $0.00 $36,736.00 $0.00 $272.00 $510.00 $127.00 $0.00 $13,130.05 $0.00 $0.00 ?? $326,560.18 Total Fees:$326,560.18 Total Payments To Date:$326,560.18 Balance Due:$0.00 BUILDING PLANS IN STORAGE ATTACHED Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 FOR' PLAN CHECK NO. _ EST. VAL. 1 ."^ I 7, '2 10/21/2005 001 Plan Ck. Deposit Validated By Date (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of .(Section 7031.5 by applicant for a permit subiegts the applicant to a civil penalty of not more than five hundred dollars JS5001).Z Address « ,- Ucense Class /T C> 0-K A-i 7 State/Zip Business Lice;eft- Telephone # Designer Name State License # Address 'City State/Zip TelephorTe # Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ^^ I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My ^worker's compensation insurance carrier aii policvpumAtfa^e: . /L~\/!^ ^" • • •> r-X>—v, IP Insurance Company ftrt&f-J &n ** //flry)^r /I^^^^^Policy No. tv<-* /J J y /D & Expiration Date_ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of CaWomia. WARNING: Failure to securk workers' compensatto/^ovtrags is unlawful, and shall subject an employer to criminal penalties and civil fines fip tojlne hundred thousand llars($100,000), in adtflftpn jto tha-costipf compsnsaHStKdanMges^rs provided for in Section 3706 of the Labor Code, interest and attorney's f •J ** \ ^T^^' f IKl^'^/IGNATURE DATE «" I hereby affirm (hat I am exempt from the Contractor's License/Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. DYES O NO 2. I (have/have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / /ontractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Page 2 of 2 [COMI&ETEUijjiiSEeTIONjE^fe--a^;rr^W"*t^fi''*B;M^^*'"M'*'»'^^*a**^^ 'Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration for or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relat'ng to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CFTY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND OSHA: An OSHA permit is required for excavations of 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under theprovisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within Y80 days from the date of/£uc^ permit or if the building or work authorized by such permit is suspended or abandoned at any time after IdavsjSection 106.4.4)the work is commenced for a period of 1 8 APPLICANT'S SIGNATURE Building Code). DATE 7 WHITE: File YELLOW: Applicant PINK: Finance eityolCaflstal Final Building Inspection Dept: Building Engineering Planning CMWD St Lite Fire Plan Check #: Permit #: Project Name: Address: Contact Person: Sewer Dist: Inspected /) Bv: U VInspected Bv: Inspected Bv: Comments: CB053648 24. HOUR FITNESS 37500SF Tl FROM SHELL TO FITNESS CENTER 1265 LAUREL TREE LN PAT Phone: 7604972834 CA Water Dist: CA *£? Date _,/ ^^A^- Inspected: o(*^i V /I Date Inspected: Date Inspected: Date: Permit Type: Sub Type: Lot: 0 / /9p-7 t/' C7[ Approved: A_ Approved: Approved: . 08/13/2007 Tl COMM Disapproved: Disapproved: Disapproved: City of Carlsbad Bldg Inspection Request For: 08/29/2007 Permit* CB053648 Title: 24 HOUR FITNESS 37500SF Description: Tl FROM SHEiL TO FITNESS CENTER Inspector Assignment: TP Sub Type: COMM 1265 LAUREL TREE LN Lot: 0 Type:Tl Job Address: Suite: Location: APPLICANT NINARAEY Owner: ASCENT BILTMORE CARLSBAD L L C Remarks: Phone: Inspector: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By: NA Entered By: CHRISTINE Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# CV070670 CLOSED Z- BANNER; PCR07009 ISSUED BILTMORE PACIFICA STEEL WEB; JOISTS-DEFERRED SUBMITTAL PCR07049 ISSUED BILTMORE PACIFICA- DEFFERED; CURTAIN WALLS SUBMITTAL PCR07062 ISSUED 24 HOUR FITNESS; REVISE CORE EXITING SYSTEM PCR07069 ISSUED 24 HR FITNESS CHANGES TO ELEC; &LAUNDRY RMS.RELOCATE WORK&MECH RJ> Inspection History Date Description Act 08/09/2007 23 Gas/Test/Repairs AP 08/06/2007 14 Frame/Steel/Bolting/Welding AP 08/06/2007 34 Rough Electric AP 08/06/2007 44 Rough/Ducts/Dampers AP 08/02/2007 19 Final Structural PI 08/02/2007 84 Rough Combo CO 07/26/2007 14 Frame/Steel/Bolting/Welding AP 07/26/2007 24 Rough/Topout WC 07/26/2007 34 Rough Electric AP Insp Comments TP TP T-CEIL 1ST FLR RESTRM TP CEIL LITES 1 ST FLR RESTRMS DUCTS 1ST FLR RESTRMS FINAL WALK THRU / CONF @ RESTROOMS CEILS T-CEIL OVER POOL AREA TP TP TP TP TP TP CEIL LITES OVER POOL AREA City of Carlsbad Bldg Inspection Request For: 08/29/2007 Permit* CB053648 07/26/2007 44 Rough/Ducts/Dampers AP TP 07/20/2007 14 Frame/Steel/Bolting/Welding PA MC 07/20/2007 24 Rough/Topout WC MC 07/20/2007 34 Rough Electric PA MC 07/19/2007 84 Rough Combo PA MC 06/26/2007 14 Frame/Steel/Bolting/Welding PA TP 06/21/2007 14 Frame/Steel/Bolting/Welding AP TP 06/18/2007 14 Frame/Steel/Bolting/Welding AP TP 06/18/2007 24 Rough/Topout . AP TP 06/18/2007 34 Rough Electric AP TP 06/18/2007 44 Rough/Ducts/Dampers AP TP 06/18/2007 ' 44 Rough/Ducts/Dampers AP TP 06/13/2007 14 Frame/Steel/Bolting/Welding AP TP 06/13/2007 24 Rough/Topout AP TP 06/13/2007 34 Rough Electric AP TP 06/12/2007 14 Frame/Steel/Bolting/Welding CO TP 06/11/2007 14 Frame/Steel/Bolting/Welding AP TP 06/11/2007 34 Rough Electric AP TP 05/24/2007 14 Frame/Steel/Bolting/Welding AP TP 05/24/2007 34 Rough Electric • AP TP 05/24/2007 44 Rough/Ducts/Dampers PA TP 05/24/2007 44 Rough/Ducts/Dampers AP TP 05/23/2007 21 Underground/Under Floor WC TP 05/23/2007 24 Rough/Topout CO TP 05/22/2007 14 Frame/Steel/Bolting/Welding AP TP 05/22/2007 19 Final Structural' NR TP 05/22/2007 44 Rough/Ducts/Dampers AP TP 11/20/2006 21 Underground/Under Floor AP TP Inspector Assignment: TP DUCTS, PLMNS OVER POOL AREA T-BAR @ RM 102,105-106,108-109,111-112,121 GROUP X NEED RFI FORSHTA8-31 PETS. RM 246 ONLY T-CEIL 3RD FLR MENS RESTRM WALL BOARD WOMENS REST RMS, KIDS ZONE, EMP. AREA DUCT PRE-WRAP MENS REST RM, SPA, MISC. ADJ AREAS MENS RESTRM., SPA MISC. ADJ. AREAS MENS RESTRM., SPA, MISC. ADJ AREAS 1STFLRSEEPLN.LOG. HARD CEIL 2ND FLR CONT. RM & SUPP GYP CEIL @ 2ND FLR LOBBY CEIL NEED TEST MECH. RM WALLS WORK UNDER'PROGRESS DUCT. PRE-WRAP GROUP RM. E. END 1ST FLR EsGii Corporation In Partnership witfi government for Quitting Safety DATE: May 23, 2006 , : OAPPLICANT JURISDICTION: Carlsbad a PLAN REVIEWER •'.'"" a FILE PLAN CHECK NO.: 053648 SET:IV PROJECT ADDRESS: 1265 Laurel Tree Dr PROJECT NAME: T. I. for 24 Hour Fitness XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: , 1X1 Esgil Corporation staff did not advise the applicant that the plan check has been completed. I Esgil Corporation staff did advise the applicant that the plan check has beenfcompleted. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Abe Doliente Enclosures: Esgil Corporation D GA D MB D EJ D PC 5/15/06 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 '> San Diego, California 92123 4 (858) 560-1468 4 Fax (858) 560-1576 EsGil Corporation In (Partnership with government for (BuiCding Safety DATE: April 21, 2006 a APPLICANT JURISDICTION: Carlsbad ^-^-PLAN REVIEWER a FILE PLAN CHECK NO.: 053648 SET: III PROJECT ADDRESS: 1265 Laurel Tree Dr PROJECT NAME: T.I. for 24 Hour Fitness The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: 24 Hour Fitness 18001 Von Karman Avenue, Suite 100, Irvine, CA 92612 Esgil Corporation staff did not advise the applicant that the plan check has been completed. XI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Nina Raey Telephone #: 714/258-1808 Date contacted: ^M^* (by.fm*) Fax #: -2401 Mail Telephone Fax >^1n Person 1 REMARKS: By: Abe Doliente Enclosures: Esgil Corporation IEI GA D MB Q EJ D PC 4/13/06 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad 053648 April 21, 2006 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 053648 PROJECT ADDRESS: 1265 Laurel Tree Dr SET: III DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 4/13/06 April 21, 2OO6 REVIEWED BY: Abe Doliente FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new complete sets of prints to: Esgil Corp. or to the bldg. dept. of the juris. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo Carlsbad 053648 ' April 21, 2O06 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. PLUMBING AND MECHANICAL CORRECTIONS PLAN REVIEWER: Glen Adamek 1. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. 3. THE A-SHEETS STILL DO NOT SHOW THE TWO REQUIRED ONE-HOUR FIRE RATED SHAFT AS SHOWN ON SHEET M2.2 AND NO FIRE RATED SHAFT CONSTRUCTION DETAILS FOUND. PLEASE CORRECT. Clearly show the required fire rated shafts for duct openings in floors as per UBC, Section 711.0. PLUMBING (2000 UNIFORM PLUMBING CODE) 14. ON SHEET P2.3 CORRECT THE ROUTING OF THE PLASTIC COMBUSTION AIR DUCTS AND THE VENT DUCTS FOR THE DIRECT VENT WATER HEATERS SHOWN THROUGH THE FIRE RATED SEPARATION AROUND THE POOL EQUIPMENT ROOM, PASSING THROUGH THE EXIT HALLWAY FROM THE POOL ROOM. PLEASE REROUTE SO FIRE AND SMOKE DAMPERS ARE NOT REQUIRED. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. In (Partnership with government for (Buifcfing Safety DATE: January 3O, 2OO6 . . • . JURISDICTION: Carlsbad . Q PLAN REVIEWER a FILE PLAN CHECK NO.: 053648 SET: II PROJECT ADDRESS: 1265 Laurel Tree Dr PROJECT NAME: T.I. for 24 Hour Fitness The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. X| The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. . XI The applicant's copy of the check list has been sent to: 24 Hour Fitness 18001 Von Karman Avenue, Suite 100, Irvine, CA 92612 Esgil Corporation staff did not advise the applicant that the plan check has been completed. X] Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Nina Raey Telephone #: 714/258-1808 Date contacted: I\?> I (o^ (by: £Aj. Fax #: -2401 Mail Telephone / Fax / In Person - REMARKS: By: Abe Doliente Enclosures: Esgil Corporation- [>3 GA Kl MB D EJ D PC 1/20/06 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ^ San Diego, California 92123 > (858)'560-1468 4> Fax (858) 560-1576 Carlsbad O53648 January 3O, 2O06 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: O53648 PROJECT ADDRESS: 1265 Laurel Tree Dr SET: II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 1/20/06 January 30, 2006 REVIEWED BY: Abe Doliente FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code,, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation; noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. .'.'.. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. • • . / A. Please make all corrections on the original tracings and submit two new complete sets of prints to: Esgil Corp. or to the bldg. dept. of the juris. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? : QYes UNo Carlsbad O53648 January 30, 2006 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave,, Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Please revise the building area analysis shown on sheet AS1.1 of the plans. Section 504.3 of the Uniform Building Code states that: "When a building houses more than one occupancy, the area of the building shall be such that the sum of the ratios of the actual area for each separate occupancy divided by the total allowable area for each separate occupancy shall not exceed one. This is a mixed occupancy building containing A-3, B & E-3 occupancies. 2A. Clearly label the floor plans the limits of the different occupancies. Plumbing, mechanical and electrical floor plans must agree with the architectural floor plans. 3. The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. See the attached correction sheet. Title 24. 4. Revise the exit analysis. At least two exits are required for the pool/spa deck and group X rooms. Clearly show the location of the two exits. 5. Rooms with more than 10 occupants may have one exit through one adjoining room. Revise exits to comply. Section 1004.2.2. Refer to the kid's club. One of the exits has more than one intervening rooms. 10. Please see the following corrections for electrical, energy, plumbing and mechanical. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Abe Doliente at Esgil Corporation. Thank you. Carlsbad O53648 January 3O, 2OO6 PLUMBING AND MECHANICAL CORRECTIONS PLAN REVIEWER: Glen Adamek 1. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. 3. Sheet A2.1 does not show the required one-hour fire rated shaft as per sheet M2.2 and no construction details of the fire rated shaft shown. Clearly show the required fire rated shafts for duct openings in floors as per UBC, Section 711.0. 5. The location of the wall between the Men's Locker Room and Kid's Club on mechanical sheet M2.1 and architectural sheets A-2.1 and A-2.2 do not agree. Clearly show the limits of fire rated occupancy separations. 6. The location of the wall between the Men's Locker Room and Kid's Club on mechanical sheet M2.1 and architectural sheets A-2.1 and A-2.2 do not agree. And one of the smoke and fire dampers on mechanical sheet M2.1 is incorrectly located. Please correct. Show the required smoke and fire dampers, at duct openings in fire rated occupancy separations as per UBC, Sections 713.10 and 713.11. 7: No response as to the storage and use of pool chemicals. Provide data on proposed hazardous material to be stored and used. UBC, Section 307 and UFC. A) Clearly show types of hazardous material is being stored or used. Provide a list of the proposed hazardous materials as per the types in UBC, Tables 3-D, and 3-E. Provide the material safety data sheets (MSDS). B) Clearly show the amounts of each type of hazardous material to be stored and in use. C) Clearly show where in the buildings each type of hazardous material is being stored or used. PLUMBING (2000 UNIFORM PLUMBING CODE) 8. No architectural response found as noted in plumbing responses? Provide calculations to show compliance with UBC, Appendix 29, (Minimum Plumbing Facilities) as per the City of Carlsbad. 10. Correct the water line sizing calculations on sheet P1.1: Correct the water meter pressure loss as per UPC, Chart A-1. The 4.5 psi is too low for 86 GPM through a 2 inch water meter. Carlsbad 053648 January 3O, 2O06 11. Provide gas line plans and calculations, showing gas meter location, gas pressures in psi, gas pressure regulator locations, pipe lengths and gas demands. UPC Section 1217.0 The gas line plans and sizing calculations on sheet P2.3 is incomplete: A) The plumbing floor plan on sheet P2.3 does not match the architectural floor plans on sheets A2.1 and A2.3 for the pool equipment room and the swimming pool room. Please correct. B) Show the location of the main public gas meter. C) Please provide the sizing calculations and plans for the medium pressure gas system from the main public gas meter to the new gas pressure regulator in the pool equipment room, including the all gas demands on the main public gas meter. D) Show the gas pressure regulator venting to the outside as per UPC, Section 1218.4. 14. Please provide the cut-sheets, listing data and installation instructions for the proposed direct-vent water heaters showing requirements for the Thru the wall venting system and the combustion air ducting. MECHANICAL (2000 UNIFORM MECHANICAL CODE) 20. The mechanical floor plan on sheet M2.1 does not match the architectural floor plans on sheets A2.1 and A2.3 for the pool equipment room and the swimming pool room. Please correct. Also provide cut-sheets and data for the proposed pool heaters to show they will fit through the doors from the outside to the pool equipment room. Correct the required access to Boiler units as per UMC Section 305.0: "Equipment shall be accessible for inspection, service repair and replacement without removing permanent construction or other equipment or disabling the function of required fire-resistant construction." 23. The mechanical floor plan on sheet M2.1 does not match the architectural floor plans on sheets A2.1 and A2.3 for the pool equipment room and the swimming pool room. Please correct. Also, please provide cut-sheets, listing data and installation instructions for the proposed swimming pool heater boilers showing requirements for the horizontal through the wall venting systems. Detail the flue (vent) terminations as per UMC Section 806.6. 24. The mechanical floor plan on sheet M2.1 does not match the architectural floor plans on sheets A2.1 and A2.3 for the pool equipment room and the swimming pool room. Please correct. Also, please provide cut-sheets, listing data and installation instructions for the proposed swimming pool heater boilers showing requirements for the horizontal through the wall venting systems. Detail the flue (vent) offsets, length, pitch and clearances as per UMC Section 805. Carlsbad O53648 January 3O, 2OO6 Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 The following disabled access items are taken from the 2001 edition of California Building Code, Title 24. Per Section 101.17.11, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. NOTE: All Figures and Tables referenced in this checklist are printed in the California Building Code, Title 24. 2. Elevator access must be provided to upper and lower levels, unless it can be shown that an exception in Section 1103B.1 is applicable. Recheck the mezzanine area. ; ;. ELEVATORS AND WHEELCHAIR LIFTS 10. Show on the plans to show that the inside of the elevator car complies with the following, per Section 1116B.1.8. The clear distances between walls, or between the walls and the door, excluding return panels, is: a) >80" by 54" (at center opening doors). b) >68" by 54" (at side-slide opening doors). c) The distance from walls to return panel is >51". 11. Show that a handrail is provided on one wall of the car, preferably the rear, per Section 1116B.11. The rails shall be smooth and the inside surface >V/z clear of the walls at a height of 32"±1" from the floor. 12. Show, or note, that call operation buttons are to be ^2" above the floor, per Section 1116B.1.10. EsGil Corporation In (Partnership witfi government for <BuiCifing Safety DATE: November 7, 2005 _o .APPLICANT JURIS,, JURISDICTION: Carlsbad a PLAN REVIEWER Q FILE PLAN CHECK NO.: 053648 SET: I PROJECT ADDRESS: 1265 Laurel Tree Dr PROJECT NAME: T.I. for 24 Hour Fitness The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I | The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: 24 Hour Fitness 18001 Von Karman Avenue, Suite 100, Irvine, CA 92612 Esgil Corporation staff did not advise the applicant that the plan check has been completed. XI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Nina Raey Telephone #: 714/258-1808 Date contacted: M^l^by:-^) Fax #: -2401 Mail Telephone >/ Fax ^ In Person REMARKS: By: Abe Doliente Enclosures: Esgil Corporation IE! GA [El MB D EJ D PC 10/25/05 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 * (858)560-1468 4 Fax (858) 560-1576 Carlsbad O53648 November 7, 2005 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: O53648 OCCUPANCY: A-3/B TYPE OF CONSTRUCTION: V-1HR ALLOWABLE FLOOR AREA: SPRINKLERS?: Yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: November 7, 2005 JURISDICTION: Carlsbad USE: 24- hour fitness ACTUAL AREA:.T.I. only - 37,500 SF STORIES: 3 HEIGHT: OCCUPANT LOAD: 805 (total) DATE PLANS RECEIVED BY ESGIL CORPORATION: 10/25/05 PLAN REVIEWER: Abe Doliente FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw.dot Carlsbad 053648 November 7, 2005 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 2. Please revise the building area analysis shown on sheet AS1.1 of the plans. Section 504.3 of the Uniform Building Code states that: "When a building houses more than one occupancy, the area of the building shall be such that the sum of the ratios of the/actual area for each separate occupancy divided by the total allowable area for each separate occupancy shall not exceed one. 3. . The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. See the attached correction sheet. Title 24. 4. Revise the exit analysis. At least two exits are required for the pool/spa deck and group X rooms. 5. Rooms with more than 10 occupants may have one exit through one adjoining room. Revise exits to comply/Section 1004.2.2. Refer to the kid's club. One of the exits may have more than, one intervening rooms. 6. Exit doors should swing in the direction of exit travel when serving any hazardous area or when the area served has an occupant load of 50 or more. . Section 1003.3.1.5. Refer to the kid's club and the pool/spa deck area. 7. Revolving, sliding and overhead doors are not permitted as exit doors if the occupant load exceeds 9 or the exit door serves a hazardous area. Horizontal sliding doors complying with UBG Standard 7-8 may be used when serving an occupant load of less than 50 in any occupancy other than Group H. Section 1003.3.1.2. Recheckthe Pro shop. .. . . « Carlsbad O53648 November 7, 2005 8. Exit doors from Group A occupancies shall not be provided with a latch or lock unless it is panic hardware. Section 1007. 9. All doors and gates, within the exit path from Group A occupancies to a public way, shall not be provided with latches or locks unless they are equipped with panic hardware. Section 1003.3.2.2. • MISCELLANEOUS 10. Please see the following corrections for electrical, energy, plumbing and mechanical. 11. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 12. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: . Yes a NO a : : The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Abe Doliente at Esgil Corporation. Thank you. ELECTRICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Morteza Beheshti • ELECTRICAL (2002 NATIONAL ELECTRICAL CODE) 1. Please provide a minimum of 1 foot-candle of emergency illumination at the floor level for the "MAIN GYM" or mezzanine areas. UBC 1003.2.9.2 & NEC 700.16. 2. Please specify the transformer ground electrode and indicate the ground electrode type? NEC 250.30 • ENERGY CONSERVATION 3. Please provide updated mechanical energy compliance forms for review. Carlsbad 053648 November 7, 2O05 4. Please provide a completed lighting energy calculations for review. New updated forms are provided. However, they are incomplete?? T-bar ceilings: Insulation may not be installed on the top of t-bar ceilings for energy compliance. Exception: Conditioned space not exceeding 2,000 square PLUMBING AND MECHANICAL CORRECTIONS PLAN REVIEWER: Glen Adamek 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. 2. Correct the statement on the Title Sheet of the plans: a) The 2001 edition of the California Building Code (CBC) adopts the 1997 Uniform. Building Code (UBC) and the 2001 California Amendments. b) The 2004 edition of the California Electrical Code (CEO adopts the 2002 National Electrical Code (NEC) and the 2004 California Amendments. c) The 2001 edition of the California Mechanical Code (CMC) adopts the 2000 Uniform Mechanical Code (UMC) and the 2001 California Amendments. d) The 2001 edition of the California Plumbing Code (CPC) adopts the 2000 . Uniform Plumbing Code (UPC) and the 2001 California Amendments. e) The 2001 edition of the California Fire Code (CFC) adopts the 2000 Uniform Fire Code (UFC) and the 2001 California Amendments. f) The 2005 edition of the California Energy Efficiency Standards. 3. Clearly show the required fire rated shafts for duct openings in floors as per UBC, Section 711.0. 4. Show the required smoke and fire dampers at duct openings in fire rated shaft enclosures as per UBC, Sections 713.10 and 713.11. 5. Clearly show the limits of fire rated occupancy separations. 6. Show the required smoke and fire dampers at duct openings in fire rated occupancy separations as per UBC, Sections 713.10 and 713.11. Carlsbad O53648 November 7, 2005 7. Provide data on proposed hazardous material to be stored and used. UBC, Section 307 and UFC. a) Clearly show types of hazardous material is being stored or used. Provide a list of the proposed hazardous materials as per the types in UBC, Tables 3-D, and 3-E. Provide the material safety data sheets (MSDS). b) Clearly show the amounts of each type of hazardous material to be stored and in use. c) Clearly show where in the buildings each type of hazardous material is being stored or used. PLUMBING (2000 UNIFORM PLUMBING CODE) 8. Provide calculations to show compliance with UBC, Appendix 29, (Minimum Plumbing Facilities) as per the City of Carlsbad. 9. Please correct the drainage fixture unit values shown on the drain, waste and vent drawings as per UPC, Table 7-3. Please use the Assembly column and correct the fixture unit values used for the water closets, urinals and drinking fountains. 10. Correct the water line sizing calculations on sheet P1.1: a) The wall mounted American Standard ultra low flush, flush valve water closets required 30 psi (not the 25 psi used) to operate. Please correct. •b) Check the total water demand used in the water line sizing calculations for the total building. The 150.5 fixture units seems low. Please provide the calculation of assumed fixture units as per UPC, Table A-2 fixture unit values. c) As per UPC, Chart A-3, the 150.5 flush valve fixture units used is about 73 GPM, Not the 70 GPM used. Please correct. d) Correct the pressure loss as per UPC, Chart A-1. The 3.5 psi is too low. Please correct. e) The water line sizing calculations to be reviewed when the sizing calculations are corrected. 11. Provide gas line plans and calculations, showing gas meter location, gas pressures in psi, gas pressure regulator locations, pipe lengths and gas demands. UPC Section 1217.0 12. Show the shower control valve and shower head locations comply with UPC, Section 412.11. 13. Detail how combustion air for fuel burning water heaters will be provided in accordance with the Uniform Plumbing Code, Section 507.0 Carlsbad 053648 November 7, 2O05 14. Please provide the listing data and installation instructions for the "Thru the wall vent Kit, Blower, Cat. 3 exhaust system." For the proposed water heater venting system. 15. Provide a drinking fountain at each floor level in assembly occupancies (except drinking and dining establishments). UBC Section 2902.2 16. As per UPC, Section 603.4.5: Water supply inlets to tanks, vets, sumps, swimming pools and other receptors shall be protected by one of following means: 1. An approved airgap; 2. A listed vacuum breaker installed on the discharge side of the last valve with the critical level not less than six (6) inches or in accordance with its listing; 3. A backflow preventer suitable for the contamination or pollution, installed in accordance with the requirements for that type of devise or assembly as set forth in this chapter. 17 UPC, Section 601.2 Identification of a Potable and Nonpotable Water System. In all buildings where potable water and not potable water systems are installed, each system shall be clearly identified. Each system shall be color coded as follows: ..-'.-.' 601.2.1 Potable Water - Green background with white lettering. 601:2.2 Nonpotable Water- Yellow background with black lettering, with the words "CAUTION: NONPOTABLE WATER, DO NOT DRINK". Table 6-1 Minimum Length of Color Field and Size of Letters. See Table. 601.2.3 Reclaimed Water- Purple in color (Pantone color#512) background and shall be imprinted in nominal % high, black, upper case letters, with the words "CAUTION: RECLAIMED WATER, DO NOT DRINK". 18. Please correct the Plumbing Fixture Schedule on sheet P1.1 for water closet TLT- 3. The Plumbing Fixture Schedule shows no WC-1 fixture, as per the Remarks. Please correct. MECHANICAL (2000 UNIFORM MECHANICAL CODE) 19. Please provide details and cut-sheets detailing the supply air, return air and outside air duqt connections to the water source heat pumps WSHP-1 and WSHP-3. sheet M2.1 is not clear as to the connections to the units and/or plenums. 20. Correct the required access to Boiler units as per UMC Section 305.0: "Equipment shall be accessible for inspection, service repair and replacement without removing permanent construction or other equipment or disabling the function of required fire-resistant construction." Carlsbad O53648 November 7, 2OO5 21. Detail the overflow (secondary) condensate discharge from air conditioning units that are in a ceiling space to readily observed locations. UMC Section 310.2. 22. Provide smoke detection in the supply air duct of an "air-moving system" for required shut-off of equipment for smoke control. UMC Section 609.0. An "air- moving system" \s a system designed to provide heating, cooling, or ventilation in .which one or more air-handling units are used to supply air to a common space or to draw air from a common plenum or space. UMC Section 203.0. 23. Detail the flue (vent) terminations as per UMC Section 806.6. Please provide listing data and installation instructions for the proposed swimming pool heater boilers showing requirements for the horizontal through the wall venting systems. 24. Detail the flue (vent) offsets, length, pitch and clearances as per UMC Section 805. Please provide listing data and installation instructions for the proposed swimming pool heater boilers showing requirements for the horizontal through the wall venting systems. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on .this list (or a copy) where the corrected items have been addressed on the plans. 5. residential buildings shall have an R-13 value. (118(f)) . : 6. Specify the following mandatory measures and provide the electrical design for the exterior lighting: <» All outdoor luminaries with lamps rater over 100 watts must have a lamp efficacy of at least 60 lumens/watt or be controlled by a motion sensor, (mercury vapor & large incandescent do not comply) «J» Cut-off shielding for outdoor luminaries rated greater than 175 watts. . •** The method of providing automatic shut-off controls (and) , »J» The method of providing multilevel switching. 7. Specify, on the plans, that the duct insulation must be a minimum of: * Climate Zones: a. 1,2, 3, 4, 5, 9 10, 11, 12, 13 =R-6 '.'• b. 6,7,8 " =R-4.2 . .- c.. 14, 15, 16 =R-8 - Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad 053648 November 7, 2005 DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 The following disabled access items are taken from the 2001 edition of California Building Code, Title 24. Per Section 101.17.11, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. NOTE: All Figures and Tables referenced in this checklist are printed in the California Building Code, Title 24. • REMODELS. ADDITIONS AND REPAIRS 1. When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B.2. These requirements apply as follows: a) The area of specific alteration, repair or addition must comply as "new" construction. b) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. c) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features. d) Existing drinking fountains (if any) must be shown to comply with all accessibility features. e) Existing public telephones (if any) must be shown to comply with all accessibility features. ENTRANCES AND CIRCULATION 2. Elevator access must be provided to upper and lower levels, unless it can be shown that an exception in Section 1103B.1 is applicable. STAIRWAYS AND HANDRAILS 3. Show that handrails are provided on each side of the stairs, per Section 1133B.4.1.1. 4. -Provide sections, details or notes to show that handrails are to be located >34" but =38" above nosing of treads, per Section 1133B.4.2.1. Carlsbad O53648 November 7, 2OO5 5. Show that handrails extend a >12" beyond top nosing, and >12"-plus-tread-width beyond the bottom nosing, per Section 1133B.4.2.2. 6. Per Section 1133B.4.2.6.1, provide details, sections or notes to show that handgrip portions of handrails are: a) >1 %" and ^1/2" in cross sectional dimension. b) The shape may provide an equivalent gripping surface. c) The handgrip portion shall have a smooth surface, without any sharp corners. 7. Stair treads shall be no less than 11" deep, measured from riser to riser. Section 1133B.4.5.3. This applies even if basic UBC provisions may allow a narrower tread. 8. Show or note that interior stair treads are marked at the upper approach and the lower tread of each stair, by a strip of clearly contrasting color, per Section 1133B.4.4, as follows: a) At least 2" wide (but not more than 4" wide). b) Placed parallel to and not more than 1" from the nose of the step or landing. c) The strip shall be as slip resistant as the other treads of the stair. 9. Note that all tread surfaces comply with Section 1133B.4.5, as follows: a) Stairtreads shall be no less than 11" deep, measured from riser to riser. b) Be slip resistant. : . c) Have smooth, rounded or chamfered exposed edges. d) Have no abrupt edges at the nosing. e) Nosing shall not project >1 Vz past the face of the riser above. f) Open risers are not permitted. ELEVATORS AND WHEELCHAIR LIFTS 10. Show on the plans to show that the inside of the elevator car complies with the following, per Section 1116B.1.8. The clear distances between walls, or between the walls and the door, excluding return panels, is: a) >80" by 54" (at center opening doors). b) >68" by 54" (at side-slide opening doors). c) The distance from walls to return panel is >51". 11. Show that a handrail is provided on one wall of the car, preferably the rear, per Section 1116B.11. The rails shall be smooth and the inside surface >11/2" clear of the walls at a height of 32"±1" from the floor. ; Carlsbad O53648 November 7, 2005 12. Show, or note, that call operation buttons are to be ^2" above the floor, per Section 1116B. 1.10. • SIGNAGE 13. Per Section 1003.2.8.6.1, tactile exit signs shall be required at the following locations: . ' a) Wherever basic UBC provisions require exit signs from a room or area to a corridor or hallway. The tactile exit sign shall have the words, "EXIT ROUTE." b) Each grade-level exit door. The tactile exit sign shall have the word, "EXIT." c) Each exit door that leads directly to a grade-level exterior exit by means of a . stairway or ramp. The tactile exit sign shall have the following words as appropriate: i) "EXIT STAIR DOWN." ii) "EXIT RAMP DOWN." iii) "EXIT STAIR UP." : iv) "EXIT RAMP UP." . d) Each exit door that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway. The tactile exit sign shall have the words, "EXIT ROUTE." e) Each exit door through a horizontal exit. The tactile exit sign shall have the words, "TO EXIT." 14. Where permanent identification is provided for rooms and spaces, raised letters shall also be provided and shall be accompanied by Braille. Section 1117B.5. 15. Provide a note on the plans stating that the signage requirements of Section 1117B.5 will be satisfied. Carlsbad O53648 November 7, 2OO5 JURISDICTION: Carlsbad VALUATION AND PLAN CHECK FEE PREPARED BY: Abe Doliente BUILDING ADDRESS: 1265 Laurel Tree Dr PLAN CHECK NO.: 053648 DATE: November 7, 2005 BUILDING OCCUPANCY: A-3/B TYPE OF CONSTRUCTION: V-1HR BUILDING PORTION T.I. 240hour fitness Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq.Ft.) 37500 cb Valuation Multiplier joer city By Ordinance Reg. Mod. VALUE ($) 1,312,500 1,312,500 Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: I Repetitive FeeRepeats Complete Review D Other D Hourly Structural Only Hour* Esgil Plan Review Fee Comments: $3,713.94 $2,414.06 $2,079.81 Sheet 1 of 1 macvalue.doc s,9i TO TOa a J J o oc cto ma a a D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB Planner APN: Address Phone (760) Type of Project & Use: Zoning: P Wl General Plan: 771Z* Net Project Density:.DU/AC Facilities Management Zone: CFD (in/out) #_Date of participation:/? PS Remaining net dev acres: Circle One ^or non-residential development: Type of land used created by this permit: • ; ) Legend: £3 'tern Complete l~l Item Incomplete - Needs your action Environmental Review Required: YES NO V TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: ' •_ Discretionary Action Required: APPROVAL/RESO. NO. PROJECT NO. YES )(j NO _ TYPE I DATE~ OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: ?££*<>& iJfruf 7fyb*$ #0 g/J &0oF •/ten? ad Coastal Zone Assessment/Compliance Project site located in Coastal-Zone? YES NO K CA Coastal Commission Authority? YES NO If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4^02; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES N0_ If NO, complete Coastal Permit Determination Form now. ... Coastal Permit Determination Log #: ... :•' . Follow-Up Actions: * x-'1;)-v- Stamp 'Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) CompletejCoasta!. Permit Determination Log ;as needed. Inclusionary Housing Fee required:YES NO A (Effective date of Inelusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES NO '-,(A3(P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!')' H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 Site Plan: CH 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, . ., , . , easements, existing and proposed structures, streets, existing street improvements, right- ' '" o'f-way width, dimensional setbacks and"existing topographical lines (including all side and rear yard slopes). . . ,_ / ..' CU 2. Provide legal description of property and assessor's parcel number. < Policy 44 - Neighborhood Architectural Design Guidelines 'iZLD n alb n ^LD n ^Cn n l£ln D &n n 1. Applicability: YES NO \S 2. Project complies YES NO Zoning: 1. Setbacks: f fl~feSu»t^ ~T~3^ ^ Front: Required Interior Side: Required Street Side: Required Rear: Required Top .of slope: Required 2. Accessory structure setbacks: Front: Required Interior Side: Required Street Side: Required Rear: Required ••• Structure separation: , .Required • •'' J ^' \ ' • , ' '. '.' . •':'•• \ .'• • ' ; 3. Lot Coverage: Required 4. Height: Required 5. Parking: Spaces Required A A//A ' Shown >^syr* shown Shown Shown Shown / . • (.• • ' flS/fcl ' \ Shown ' Shown Shown Shown Shown flJ/L~ Showni MA Showni ck/* OI-O((A> iHbl** Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown ?Wn Additional Comments 6orroction it 1 -J'Ipfi^p nhftw— on Shnnt 1 — thp tntnl niimhnr -nf narUnn -anar.ns TnTTOlriHri flnrt rHmiirHri-nri nitn fnr aarh iitp npr Thnntnr 71 4.4 — Corruption #7 - IsJJiaw? •any proposed roof mounted equipment equipment be screened by an existinq Pll L L 1 L _) tPmci0i0 SPP^J nft ?tt?^nftn n^nrinutrv'fn r~ d x y fovfmowrtfo (rflv/pr*<'&Ktr- wt-fr ) . associated with this buildinq permit? If so, will the parapet wall or is new screeninq material required? ^. , — . j,±,.~r -jf-f— / ilfYlDlfc£i>. j/c? r& & *J /Jbflw J $h((&f f / /» / <* A? & **?/{ T:y? " fy#e, t/-L- OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 DATE BUILDING ADDRESS City of Carlsbad Public Works BUILDING PLANCHECK CHECKLIST En gin e e r 1 n g PLANCHECK NO L\/\ PROJECT DESCRIPTION ASSESSOR'S PARCEL NUMBER ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build D A Right-of-Way permit is required prior to construction of the following improvements DENIAL Please see the attached report of deficiencies marked witr^ET Make necessary corrections to plans or specifications for compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review Date Date Date By FOR OFFICIAL U§E ONLY INEERING AUTHORIZATION TO ISSUE BUILDING PERMIT Date ATTACHMENTS D Dedication Application D Dedication Checklist U Improvement Application D Improvement Checklist El Neighborhood Improvement Agreement D Grading Permit Application D Grading Submittal Checklist D Right-of-Way Permit Application [] Right-of-Way Permit Submittal Checklist and Information Sheet ENGINEERING DEPT CONTACT PERSON _ Taniya Barrows City of Carlsbad Address 1635 Faraday Avenue, Carlsbad, CA 92008 Phone (760) 602-2773 _ CFD INFORMATION Parcel Map No Lots Recordation Carlsbad Tract A-4 Carlsbad, CA 920081-7314 • (760) 6O2-272O - FAX (760) 602-^82 BUILDING PLANCHECK CHECKLIST SITE PLAN ,ND ~RD H L~H 1 Provide a fully dimensioned site plan drawn to scale Show A North Arrow F Right-of-Way Width & Adjacent Streets B Existing & Proposed Structures G Driveway widths C Existing Street Improvements H Existing or proposed sewer lateral D Property Lines (show all dimensions) I Existing or proposed water service E Easements J Existing or proposed irrigation service D 2 Show on site plan A Drainage Patterns 1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course 2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building " B Existing & Proposed Slopes and Topography C Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception D Sewer and water laterals should not be located within proposed driveways, per standards CD 3 Include on title sheet A Site address B Assessor's Parcel Number C Legal Description For commercial/industrial buildings and tenant improvement projects, include total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc) previously approved EXISTING PERMIT NUMBER DESCRIPTION Show all existing use of SF and new proposed use of SF. Example: Tenant Improvement for 3500 SF of warehouse to 3500 SF of office. F \BUILDINGPLANCHECKCKLST FORM doc o Rev 7/14/00 BUILDING PLANCHECK CHECKLIST ./ DISCRETIONARY APPROVAL COMPLIANCE 4a Project does not comply-with the following Engineering Conditions of approval for_ ' /li^iliv/iix-//i/>i ' .ri'ii/i, Y, .. /r(Project No <tDM?^ \ {YjJii O i A^_ D D D 4b All conditions are in compliance Date DEDICATION REQUIREMENTS L~H CZ1 CH 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm dram or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 16.330 . pursuant to Carlsbad Municipal Code Section 18 40 030 Dedication required as follows Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 Y2" x 11" plat map and submit with a title report All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit Attached please find an application form and submittal checklist for the dedication process Submit the completed application form with the required checklist items and fees to the Engineering Department in person Applications will not be accept by mail or fax Dedication completed by Date IMPROVEMENT REQUIREMENTS D CD 6a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 81.650 . pursuant to Carlsbad Municipal Code Section 1840040 Public improvements required as follows Attached please find an application form and submittal checklist for the public improvement requirements A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process The completed application form and the requirements on the F \BUILDING PLANCHECK CKLST FORM doc BUILDING PLANCHECK CHECKLIST ..ST D D D checklist must be submitted in person Applications by mail or fax are not accepted Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit Improvement Plans signed by Date EH CD 6b Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 1840 Please submit a recent property title report or current grant deed on the property and processing fee of $ 400 00 so we may prepare the necessary Neighborhood Improvement Agreement This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit Future public improvements required as follows CH CU CH 6c Enclosed please find your Neighborhood Improvement Agreement Please return agreement signed and notarized to the Engineering Department Neighborhood Improvement Agreement completed by Date D D D 6d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 15 16 060 of the Municipal Code [D CD d 7a Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities in cubic yards (cut, fill import, export and remedial) This information must be included on the plans. D D D 7b Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit Grading Inspector sign off by Date D D D 7c Partial Site Release from Engineering Inspector F BUILDING PLANCHECK CKLST FORM doc BUILDING PLANCHECK CHECKLIST .. ST 2ND 3RD [U CD [U 7d Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) G n D 7e No Grading Permit required Q D D 7f If grading is not required, write "No Grading" on plot plan MISCELLANEOUS PERMITS D D D 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way Types of work include, but are not limited to street improvements, tree trimming, driveway construction, tying into public storm dram, sewer and water utilities Right-of-Way permit required for D 9 INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List You may telephone (760) 438-2722, extension 7153, for assistance Industrial Waste permit accepted by Date NPDES PERMIT D D D 10a Storm Water Requirements Applicability Checklist Completed d CH D 10b Priority Determination and Compliance a Priority Project a Subject to Standard Permanent Storm Water BMPs a Exempt D 11 FEES Required fees are attached a No fees required WATER METER REVIEW D D D 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low-flow conditions If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used • All single family dwelling units received "standard" 1" service with 5/8" service F \BUILDING PLANCHECK CKLST FORM doc ^ST «ND oRD ODD BUILDING PLANCHECK CHECKLIST • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm) A typical fixture count and water demand worksheet is attached Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit • Maximum service and meter size is a 2" service with a 2" meter • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand (manifolds are considered on case by case basis to limit multiple trenching into the street) Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval The developer must provide these calculations Please follow these guidelines 1 If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets If so, at the water meter station, the demand in gpm may be listed there Irrigation services are listed with' a circled "I", and potable water is typically a circled "W The irrigation service should look like STA 1+00 Install 2" service and 5 meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach) Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use Once you have received a good example of irrigation calculations, keep a set for your reference In general the calculations will include • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA) As long as the project is located within the City recycled water F \BUILDING PLANCHECK CKLST FORM OoC Rev 7/14/00 1 ST 2ND 3R BUILDING PLANCHECK CHECKLIST service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future CD O 12c Irrigation Use (where recycled water is available) 1 Recycled water meters are sized the same as the irrigation meter above 2 If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development For subdivisions, this should have been identified, and implemented on the improvement plans Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this 13 Additional Comments: \r , W (f F WILDING PLANCHECK CKLST FORM doc ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D Estimate based on unconfirmed information from applicant D Calculation based on building plancheck plan submittal La\}£a\Address Prepared by _Date Bldg Permit No Checked by Date EDU CALCULATIONS: List types and square footages for all uses Types of Use ^j>X\ ** &£Mrt Sq Ft /Units 3^*0^0 Types of Use _ Sq Ft /Units APT CALCULATIONS List types and square footages for all uses Types of Use' &)v&tl ^fl Au^n Sq Ft /Units 3 J Types of Use Sq Ft /Units EDU's EDU's ADT's ADT's 33 13/9- FEES REQUIRED WITHIN CFD 4^-YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee)DNO D 1 PARK-IN-LIEU FEE FEE/UNIT PARK AREA & # X NO UNITS =$. TRAFFIC IMPACT FEE ADT's/UNITS I3/P"~X FEE/ADT BRIDGE AND THOROUGHFARE FEE (DIST #1 DIST#2. ADT's/UNITS D 4 FACILITIES MANAGEMENT FEE UNIT/SO FT 5 SEWER FEE EDU's BENEFIT AREA EDU's X FEE/ADT ZONE X FEE/SOFT/UNIT DIST #3 =s =$_ X FEE/EDU FEE/EDU D 6 SEWER LATERAL ($2,500) D 7 DRAINAGE FEES PLDA_ ACRES =$_ =$_ X HIGH. FEE/AC /LOW =$_ D 8 POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION F \FEE CALCULATION WORKSHEET doc 1 of 2 Rev 7/14/00 ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D 9 RECLAIMED WATER FEES UNITS CODE CONNECTION FEE METER FEE TOTAL OF ABOVE FEES* $_ *NOTE This calculation sheet is NOT a complete list of all fees which may be due Dedications and Improvements may also be required with Building Permits F \FEE CALCULATION WORKSHEET doc 2 of 2 Rev 7/14/00 Carlsbad Fire Department Plan Review Requirements Category: . TI , COMM Date of Report: 02-14-2006 Reviewed by: Name: Address: ^f Permit #: CB053648 Job Name: 24 HOUR FITNESS 37500SF Job Address: 1265 LAUREL TREE LN CBAD •INCOMPLETE - Tho itom you havo oubmitted for review is incomplete. At this time, this office cannot lv conduct 3. T*£vi£\v to dct&rtnitui- cotxipli&iicc with, th arefully all comments attaohod. Ploaao rooubmit the neoeooary plans and/or specifications, with changes "clouded"^ to this office for roviow and approval. Conditions: Cond: CON0000840 __APPROVED:! THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. 1 . Put correct address on plans. 2. Please indicate on plans if pool chemicals will be stored on site. If so, note that Material Safety Data Sheets will be provided on site and chemicals will be stored in accordance with the CFC. 3. Key note 15-22 indicates fire sprinkler riser. Keynote 15-22 was not found on the plans. Please show location of fire sprinkler riser. 4. Please note on plans that a pre-meeting to discuss the underground piping for the fire sprinkler system will be required prior to installation. 5. The gate to the pool/spa area shall meet the requirements of the State. Plans currently show gate to be 4 ft. high. - 3* 6. Plans currently show a latching device on the gate to the pool area. Please note on plans that ~ if an automatic lock is provided as well, a knox box will be required. l Entry: 10/21/2005 By: pp Action: CO Entry: 02/14/2006 By: gr Action: AP Carlsbad Fire Department Plan Review Requirements Category: TI, COMM Date of Report: 10-25-2005 Reviewed by: Name: NINA RAEY Address: SUITE 3R 1342 BELL AVE TUSTIN CA 92780 Permit #: CB053648 Job Name: 24 HOUR FITNESS 37500SF , Job Address: 1265 LAUREL TREE LNCBAD INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. , Conditions: Cond: CON0000840 1. Put correct address on plans. \ _ . 2. Please indicate on plans if pool chemicals will be stored on site. If so, note that Material Safety Data Sheets will be provided on site and chemicals will be stored in accordance with the CFC. 3: Key note 15-22 indicates fire sprinkler riser. Keynote 15-22 was not found on the plans. Please show location of fire sprinkler riser. 4. Please note on plans that a pre-meeting to discuss the underground piping for the fire sprinkler system will be required prior to installation. 5. The gate to the pool/spa area shall meet the requirements of the State. Plans currently show gate to be 4 ft. high. . 6. Plans currently show a latching device on the gate to the pool area. Please note on plans that if an automatic lock is provided as well, a knox box will be required. Entry: 10/25/2005 By: pp Action: CO a H i M A j L A S C 0 L A structural engineers 23682 birtcher drive lakeforest.ca.92630(949)770-9967tel(949)770-9542fax STRUCTURAL CALCULATIONS for 24 HOUR FITNESS MISCELLANEOUS HVAC CARLSBAD, CA ARCHITECT:S cheer Tanaka Dennehy Riley, Architects Building Department submittal December 20, 2005 Lj; Ljij• i i UJ .LJJI JL r~~ I »»«««»«» n r 2<_ EF $« & nII fcz r O x cz H — i -B •m^aaua!^^' Jllt_ ^£«»j CEj W 24x6& i i J .1 V.J m,co! til (E) H [2x14 | CE; H \e» W 12x14 _X S5HI 2 ,ro Ix UJ mtnX UJ RAMSBEAM V2.0 - Gravity Beam Design Licensed to: Shimaji & Lascola, Inc.- Job: 24 Hour Fitness SPAN INFORMATION: EFB1 (W18x40) Beam Size (User Selected) = W18X40" Total Beam Length (ft) =33.50 COMPOSITE PROPERTIES (No Concrete thickness ( Unit weight concrete f'c (ksi) Decking Orientation Decking type Distance to Adjacent beff (in) Seff (in**3) leff (in**4) Stud length (in) = Stud Capacity (kips) # of studs: Max Number of Stud Rows LOADS: Self Weight = 0.040 k/ft Steel Code: AISC 9th Ed. Fy = 50.0 ksi Shored) : n) (pcf) Left • 2.50 110.00 3.50 perpendicular . VERCO W3 Formlok (ft) 100.50 ' 98.99 1477.45 4.50 q = 8.9 66 Partial 1, Percent Beam: 10.67 Y bar (in) Str (in**3) Itr (in**4) Stud diameter (in) = 17 Actual = 30 of Full Composite Right 2.50 110.00 3.50 perpendicular VERCO W3 Formlok Beam: 10. 67 17.18 114.05 = 1903.42 0.75 Action = 44.91 Point Loads (kips): Dist 3.00 Line Loads Distl 0.00 DL Pre DL 0.70 (k/ft) : Dist2 33.50 0.00 DL1 0.747 LL 0.00 DL2 0.747 Flange Bracing Top Bottom No No Pre DL1 0.500 Pre DL2 0.500 SHEAR: MOMENTS: Span Center Max V (kips) = 28.11 fv (ksi) = 4.99 .LLl 0.853 Fv = 20.00 LL2 0.853 Cond Pre DL Max + Moment kip-ft 75.8 231.1 @ ft 16.7 16.7 Mmax/Seff Mprecmp/Sx+Mpost/Seff Controlling 231.1 fc (ksi) = 0.52 REACTIONS (kips): Initial reaction DL reaction Max + LL reaction Max + total reaction 16.7 Fc = Lb Cb Tension Flange ft fb Fb 13.29 33.00 28.02 33.00 32.13 45.00 28.02 33.00 Comp Flange fb Fb 13.29 33.00 1.58 Left Right 9.05 9.05 13.82 13.25 14.29 ' 14.29 28.11 27.54 DEFLECTIONS: (Camber = 3/4) Initial load (in) at 16.75 ft = -0.862 Live load (in) at 16.75 ft = -0.564 Post Comp load (in) at 16.75 ft = -0.733 Total load (in) at 16.75 ft = -1.596 L/D L/D L/D L/D 466 713 548 252 RAMSBEAM V2.0 - Gravity Beam Design Licensed to: Shimaji & Lascola, Inc. Job: 24 Hour Fitness SPAN INFORMATION: EFB2 (W18x35) Beam Size (User Selected) = W18X35 Total Beam Length (ft) = 32.00 COMPOSITE PROPERTIES (Not Shored): Concrete thickness (in) Unit weight concrete (pcf) fc (ksi) Decking Orientation Decking type Distance to Adjacent (ft) beff (in) = 96.00 Seff (in**3) = 83.84 leff (in**4) = 1244.27 Stud length (in) = 4.50 Stud Capacity (kips) q = 8.9 # of studs: Max = Number of Stud Rows Steel Code: AISC 9th Ed. Fy = 50.0 ksi Left 2.50 110.00 3.50 perpendicular VERCO W3 Formlok Beam: 10.67 Y bar(in) Str (in**3) Itr (in**4) Stud diameter Right 2.50 110.00 3.50 perpendicular VERCO W3 Formlok Beam: 10.67 17.29 98.64 = 1658.20 (in) = 0.75 q = 64 Partial = 17 Actual = 24 1, Percent of Full'Composite Action = 35.87 LOADS: Self Weight = 0.035 k/ft Point Loads (kips): Dist DL Pre DL LL 12.00 0.62 0.00 0.00 Line Loads (k/ft): Distl Dist2 DL1 DL2 0.00 32.00 0.747 0.747 Flange Bracing Top Bottom No No Pre DL1 0.500 Pre DL2 0.500 SHEAR:Max V (kips) = 26.55 fv (ksi) = 5.25 LLl 0.853 Fv = 19.13 LL2 0.853 MOMENTS: Span Cond Moment @ kip-ft ft Center Pre DL 68.5 16.0 Max .+ 213.0 15.9 Mmax/Seff Mprecmp/Sx+Mpost/Seff Controlling 213.0 15.9 Lb Cb Tension Flange ft fb Fb 14.27 33.00 30.49 33.00 34.95 45.00 30.49 33.00 Comp Flange fb Fb 14.27 33.00 fc (ksi) =0.53 Fc =1.58 REACTIONS (kips): Initial.reaction DL reaction Max + LL reaction Max + total reaction Left Right 8.56 8.56 12.90 12.75 13.65 13.65 26.55 26.39 DEFLECTIONS: (Camber = 3/4) Initial load (in) at 16.00 ft = -0.854 Live load (in) at 16.00 ft = -0.558 Post Comp load (in) at 16.00 ft = -0.738 Total load (in) at 16.00 ft = -1.591 L/D L/D L/D L/D 450 689 521 241 JOB. SH1MAJI& LASCOLA structural engineers ENGINEER SHEET NO. _ DATE 7 ;Vti p.f">^xio!4^\_l Vu t< ( !.. ill ! ffit F I •I. I =7 /v5ft-~ ~ -=r" --,7ii LjLJl__i r .!.< i — *J (• 4 - Ti > " "'"T&Yi "j^?i r iT T7i, - J- -,~T] , : M I! O|I •Tsu 05-17-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No:PCR07069 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: Applicant: RAEY NINA 1342BELLAVE TUSTIN CA 714-258-2401 1265 LAUREL TREE LN CBAD PCR 2120402500 Lot#: $0.00 Construction Type: CB053648 0 NEW 24 HR FITNESS CHANGES TO ELEC &LAUNDRY RMS.RELOCATE WORK&MECH RMS Status: ISSUED Applied: 04/03/2007 Entered By: KG Plan Approved: 05/17/2007 Issued: 05/17/2007 Inspect Area: Owner: ASCENT BILTMORE CARLSBAD L L C 111 W MONROE ST #1111 PHOENIX AZ 85003 Plan Check Revision Fee Additional Fees $360.00 $0.00 Total Fees:$360.00 Total Payments To Date:$360.00 Balance Due:$0.00 Inspector: FINAL APPROVAL Date: 'Clearance: NOTICE: Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 FOR OFFICE USE PLAN CHECK NO. EST. VAL. Plan Ck". Deposit. Validated By Date 7 Address (include Bldg/Suite #)Business Name (at this address) Legal Description Lot No. Subdivision Name/Number Unit No.Phase No.Total # of units Assessor's Parcel #Existing Use" fa .000 Proposed Useo Descri[jtionofWork SQ.FT.# of Stories # of Bedrooms # of Bathrooms Name Address City State/Zip Telephone #Fax* B^Agent for Owner,!', Name Address City State/Zip Telephone # ..- ~ ,'/, ^.-.. .-.y*>VV.^. Name Address City State/Zip Telephone # (Sec. 70315 Business and Professions Code: Any City or County which requires a permit to construct alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). Name State License # Designer Name State License # [6. :yyORKER^COM^| Address License Class Address MSSSPJf?"- '•" "'-•>:'., -" --• v^vc- "" "*."^ City City Vij'.T.,- •> • " State/Zip City Business License # State/Zip •V < , •'••-••.W, Telephone # Telephone # / V«$&|$$pS&&*&/. j Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. D I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company . Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars($100,000), in addition to the cost of compensation, damages are provided for in Section 3706 of the Labor Code, interest and attorney's fees. SIGNATURE DATE •QWNER^BUILDER DECLARATION ^yI hereby affirm that I am exempt from the Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of properly who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law). D I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES D NO 2. I (have/have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / Contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance , PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Page 2 of 2 Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration for or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND OSHA: An OSHA permit is required for excavations of 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced withf\ 139 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period/Jn3f$a)<jJ|S5cTSon 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance EsGil Corporation In (Partners/Up with government for Quitting Safety DATE: May 17, 2OO7 a APPLICANTm JURIS. JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 053648 Rev 1 (PCR07069) SET: III PROJECT ADDRESS: 1265 Laurel Tree Lane PROJECT NAME: T. I. for 24 Hour Fitness The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 1X1 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of/the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Nina Raey 1342 Bell Ave # 3K, Tustin, CA •VI?'''' • "•' • Esgil Corporation staff did not advise the applicant that the plan check has been completed. X] Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Nina Raey Telephone #: 714/258-1808 Date contacted: 5/17/07 (by: ga) walk-in Fax #: -2401 Mail Telephone Fax In Person XI REMARKS: The City Building Official to review evidence of Health Department approval (for proposed changes for the public pool requirements).Revision I includes relocation of laundry and electrical and mechanical rooms. By: Glen Adamek for Abe Doliente Enclosures: Esgil Corporation GA D MB D EJ D PC 5/17/07 log-in and log-out 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 *• (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In <PartnersHip with government for (BuiUing Safety DATE: May 3, 2007 a/APPLICANT JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 053648 Rev 1 (PCR07069) SET: II PROJECT ADDRESS: 1265 Laurel Tree Lane PROJECT NAME: T. I. for 24 Hour Fitness The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. . - The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Nina Raey 1342 Bell Ave # 3K, Tustin, CA Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Nina Raey Telephone #: 714/258-1808 Date contacted: $f*frf(by: jfa^ Fax #: -2401 Mail —"Telephone Fax -"m Person XI REMARKS: Revision I includes relocation of laundry and electrical and mechanical rooms. By: Glen Adamek for Abe Doliente Enclosures: Esgil Corporation El GA E3 MB D EJ D PC 4/20/07 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 , Carlsbad O53648 Rev 1 (PCRO7069) May 3, 2OO7 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 053648 Rev 1 (PCRO7O69) PROJECT ADDRESS: 1265 Laurel Tree Lane DATE PLAN RECEIVED BY. DATE REVIEW COMPLETED: ESGIL CORPORATION: 4/20/07 May 3, 2O07 REVIEWED BY: Glen Adamek for Abe Doliente FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? Q Yes a No A) YOU SENT ALL THREE SETS DIRECTLY TO ESGIL CORPORATION NOT AS FOLLOWS. Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning. Engineering & Fire Departments until review by EsGil Corporation is complete. Carlsbad 053648 Rev 1 (PCR07069) May 3, 2OO7 PLUMBING AND MECHANICAL CORRECTIONS PLAN REVIEWER: Glen Adamek 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. 2. The health department must review the proposed changes to the restrooms serving the public swimming pool. The City Building Official to review evidence of Health Department approval (for proposed changes for the public pool requirements). PLUMBING (2000 UNIFORM PLUMBING CODE) 3. Sheet P3.1 and sheet P2.3 does not show the gas line from the private gas sub meter to the public gas meter outside the building and revised sizing for addition demands. Please provide complete gas line plans and calculations. Show the existing gas meter and pipe sizing from the existing gas meter to the new fixtures, showing gas pressures, pipe lengths and gas demands both new and existing. UPC Section 1217.0 4. The clothes washer data provided does not include the installation instruction and the drainage receptor sizing design and required foundation and hold-down design? Please provide installation instructions for the commercial clothes washers showing the required foundations, hold-downs, and drainage requirements (trench drain sizing?). Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. EsGil Corporation In Partnership witK government for (BuiCefing Safety DATE: April 13, 20O7 g^APPLICANT JURISDICTION: Carlsbad / a PLAN REVIEWER a FILE PLAN CHECK NO.: 053648 Rev 1 (PCR07069) SET: I PROJECT ADDRESS: 1265 Laurel Tree Lane PROJECT NAME: T. I. for 24 Hour Fitness The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. IXl The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Nina Raey 1342 Bell Ave # 3K, Tustin, CA Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Nirva Raey &**•) Telephone #: 714/258-1808 Date contacted: tyM (by: j|x) Fax #: - 2401 Mail '-^'Telephone </ Fax .^ In Person [XJ REMARKS: Revision I includes relocation of laundry and electrical and mechanical rooms. By: Abe Doliente Enclosures: Esgil Corporation IE! GA IEI MB D EJ n PC 4/5/07 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad O53648 Rev 1 (PCR07069) April 13, 2OO7 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: O53648 Rev 1 (PCR07O69) PROJECT ADDRESS: 1265 Laurel Tree Lane DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL CORPORATION: 4/5/07 April 13, 2007 REVIEWED BY: Abe Doliente FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? Q Yes a No Carlsbad O53648 Rev 1 (PCRO7O69) April 13, 2OO7 Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. * ELECTRICAL PLAN REVIEW • 2002 NEC • PLAN REVIEWER: Morteza Beheshti 1. All electrical sheets of the plans are required to be signed by the California licensed engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. Business and Professions Code. 2. Please show and design for the lighting plan changes. • ENERGY CONSERVATION 3. Please provide new worksheets for the lighting changes to show compliance with current lighting energy standards. Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad O53648 Rev 1 (PCRO7O69) April 13, 2007 PLUMBING AND MECHANICAL CORRECTIONS PLAN REVIEWER: Glen Adamek 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. 2. The City Building Official to review evidence of Health Department approval (for proposed changes for the public pool requirements). PLUMBING (2000 UNIFORM PLUMBING CODE) 3. Please provide complete gas line plans and calculations. Show the existing gas meter and pipe sizing from the existing gas meter to the new fixtures, showing gas pressures, pipe lengths and gas demands both new and existing. UPC Section 1217.0 4. Please provide cut-sheets and installation instructions for the commercial clothes washers showing the required foundations, hold-downs, and drainage requirements (trench drain sizing?). MECHANICAL (2000 UNIFORM MECHANICAL CODE) 5. Please provide the cut-sheets and installation instructions for the commercial clothes dryers including the venting requirements as per UMC, Section 504.3.3. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad O53648 Rev 1 (PCRO7O69) April 13, 2007 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad (PCR07069) PLAN CHECK NO.: O53648 Rev 1 PREPARED BY: Abe Doliente DATE: April 13, 2007 BUILDING ADDRESS: 1265 Laurel Tree Lane BUILDING OCCUPANCY: A-3/B TYPE OF CONSTRUCTION: V-1HR BUILDING PORTION Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) cb Valuation Multiplier By Ordinance Reg. Mod. VALUE ($) Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance $360.00 Type of Review: Repetitive Fee Repeats Complete Review D Other r-n Hourly Structural Only 3 Hours Esgil Plan Review Fee $288.00 * Based on hourly rate Comments: Sheet 1 of 1 macvalue.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER fcg FCR, O"l ~<£>°( DATB'M - to " •••^^^•^^^^^WM^B^M^M^^^^^^^^^^^M^^^M^^HMBM^^^^^^^^^v ^•••••^^^••^^••^^^^•^^^ ADDRESS . Lcuuur&l Tr^e RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR « $10,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER DATE oocs/Mlsfonns/Ptannlng Englneertno Approvals Carlsbad Fire Department COPY Plan Review Requirements Category: PCR , Date of Report: 04-19-2007 Name: Address: Reviewed by: Permit #: PCR07069 . , Job Name: 24 HR FITNESS CHANGES TO ELEC Job Address: 1265 LAUREL TREE LN CBAD «iiifiifti>iBfefi^&wB"fti8^WP^%u have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0002016 [MET] THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES-OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 04/19/2007 By: GR Action: AP c25 C£<«C ffi fi-. 2 Si < }~ u.) S55Sgw<£§50iujO £*£oSfc- gSiSi , *-!^iM a • y= P hi i•> /\, sKXcolJJ" fVOH^ag ^ ^o8p^4 n ^ a. 0£lO !jfj|zO L(V ||te|| p .Bi^iZQ ^ "!i?5s ^ oI 5I A!-1 "V ]|