HomeMy WebLinkAbout1265 LAUREL TREE LN; ; CB063273; Permit03-16-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB063273 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 1265 LAUREL TREE LN CBAD Tl Sub Type: 2120402500 Lot#: $2,780,000.00 Construction Type: Reference #: 24 HOUR FITNESS-49,275 SF Tl SHELL TO OFFICE INDUST 0 IFR Applicant: LILIANA LEDERMAN STE 105 3080 BRISTOL ST COSTA MESA 92626 7147541197 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check*: Owner: ASCENT BILTMORE CARLSBAD L L C 111 WMON ROE ST #1111 PHOENIX AZ 85003 ISSUED 11/15/2006 LSM 03/16/2007 03/16/2007 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $6,662.61 Meter Size $0.00 Add'l Reel. Water Con. Fee $4,330.70 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $583.80 PFF (3105540) $0.00 PFF (4305540) $0.00 License Tax (3104193) $0.00 License Tax (4304193) $200,269.00 Traffic Impact Fee (3105541) $0.00 Traffic Impact Fee (4305541) $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Master Drainage Fee Sewer Fee $0.00 Redev Parking Fee $0.00 Additional Fees HMP Fee TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $50,596.00 $0.00 $0.00 $0.00 $21,431.00 $0.00 $356.00 $812.00 $537.00 . $0.00 $18,343.44 $0.00 $0.00 ?? $303,921.55 Total Fees:$303,921.55 Total Payments To Date:$303,921.55 Balance Due:$0.00 iUILDING PLANS J/L IN STORAGE ^ATTACHED Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. ERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1 635 Faraday Ave., Carlsbad CA 92008 1, PROJECT INFORMATION FOR OFFICE USE ONLY PLAN CHECK NO. EST. VAL. PlanCk. Deposit. Validated By Date 17-^4 pluda Bldg/Suite^ J^ Legal Description . . Lot No. Subdivision Name/Number UntfNo."tof ^ of EAMGfto ^bfojbA H*fr#~I Existing Use .T «' UnKNp. _ Phase No.g£s Assessor's Parcel #50^5 Parcel # _l-CfiO-£<5 Existing Use • vMJAMrSQ.FT.Description of Work i^KRf Tm*&7v#weiK>r ^i&ju-ip 2, CONTACT PERSON (if different from applicant) # of Stories # of Bathrooms 46,^75«f 5>S7S£fe£ Name Fax* Name " " Address City State/Zip Telep'h 5, CQ8TOA(npR-COMPANY NAME '.'-.'" \ - (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). L. U £ A.:* t>i <!T<j.Co. fV7O 1-iAiOA lAsT/> j^a SA»>»/> Name State License # s\~~l st f\~t JLO /ZQf Address License Class A f City State/Zip City'Business License # _ Telei Designer Name State License # Address City State/Zip Telephone # Workers' Compensation Declaration: I hereby^affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.. D I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company f^ATlGiuA\ \)/\.itt^ fi'-fi-Tfe Policy No.-»ir>-»•'* **Expiration Date_ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand I dollars($100,000), in addition to the cost of compensation, damages are provided for in Section 3706 of the Labor Code, interest and attorney's fees. ^SIGNATURE ' ^/vyx^^w*^— , DATE 3~I<.~O~7 7, QWN£R*UttDER DECtARATfOS ' ""_ " , . ' ^ s I hereby affirm that I am exempt from the Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law). ' • D I am exempt under Section', : Business and Professions Code for this reason: : 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES D NO 2. I (have/have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number/ contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / /ontractors license number): ' ; ; . 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE _DATE WHITE: File YELLOW: Applicant PINK: Finance RMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Page 2 of 2 COMPLETE THIS SECTION TOR WON-RES/OEWTML BUILDING PERMITS ONLY * Is the applicant or future building occupant required to submit a business plan, acutely hazardous material^ registration for or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES BTNO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES IzNO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8. CONSTRUCTION LiMOIN6ASi*<CY j I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code). LENDER'S NAME "_ : ; LENDER'S ADDRESS 9, APRICAW CERTIFICATION , I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. . OSHA: An OSHA permit is required for excavations of 5'0" deep and demolition or construction of structures over 3 stories in height. . EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 1 sAitays from the data of suchoermit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a periodoTTSp aeys'JSectionjUje.44 Uniform Building Code). APPLICANT'S SIGNATURE/ I M/f/l/J/f/tA DVIA^ - DATE WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Final Building Inspection Dept: Building Engineering Planning CMWD St Lite Fire Plan Check #: Permit #: Project Name: Address: Contact Person: Sewer Dist: CB063273 24 HOUR FITNESS-49,275 SF Tl SHELL TO OFFICE 1265 LAUREL TREE LN Phone: CA Water Dist: CA Lot: Date: 08/13/2007 Permit Type: Tl Sub Type: INDUST 0 Inspected By: Inspected By: Inspected By:_ Date Inspected: Date Inspected: Date Inspected: fafe.. ApprovedX- .Approved: . Approved: Disapproved: Disapproved: Disapproved: Comments: City of Carlsbad Bldg Inspection Request For: 08/29/2007 Permit* CB063273 Title: 24 HOUR FITNESS-49,275 SF Tj Description: SHELL TO OFFICE Inspector Assignment: TP Type:TI Sub Type: INDUST Job Address: 1265 LAUREL TREE LN Suite: lot: 0 Location:/. APPLICANT LILIANA LEDERMAN Owner: ASCENT BILTMORE CARLSBAD L L C \ Remarks: Phone: Inspector: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By: NA Entered By: CHRISTINE Act Comments Comments/Notices/Holds CV070670 PCR07009 PCR07049 PCR07062 PCR07069 Associated PCRs/CVs Original PC# CLOSED Z- BANNER; BILTMORE PACIFICA STEEL WEB; JOISTS-DEFERRED SUBMITTAL BILTMORE PACIFICA- DEFFERED; CURTAIN WALLS SUBMITTAL 24 HOUR FITNESS; REVISE CORE EXITING SYSTEM 24 HR FITNESS CHANGES TO ELEC; &LAUNDRY RMS.RELOCATE WORK&MECH Rl> ISSUED ISSUED ISSUED ISSUED Inspection History Date Description Act Insp 08/09/2007 89 Final Combo CO TP 07/19/2007 84 Rough Combo NR MC 07/17/2007 84 Rough Combo PA MC 07/11/2007 84 Rough Combo PA PC 07/05/2007 84 Rough Combo AP TP 07/02/2007 84 Rough Combo^- PA TP 06/29/2007 14 Frame/Steel/Bolting/Welding PA TP 06/28/2007 14 Frame/Steel/Bolting/Welding PA TP Comments ) • ' ' COMPLETE ALL WORK INCLUDING FIRE CAULKING, SEE CARD ON SITE FOR ROOMS 2ND FLR CORRIDOR T-CEIL 2ND FLR. LG. RMS CEIL LITES 2ND FLR LG. RMS- DUCTS,HP(INCL FIREWRAP DUCT) T-CEIL 2ND FLR OFFICES 2ND FLR PMTR CEIL ROOMS T-CEIL 3RD FLR OPEN AREAS City of Carlsbad Bldg Inspection Request For: 08/29/2007 Permit* CB063273 06/28/2007 34 Rough Electric PA TP 06/28/2007 44 Rough/Ducts/Dampers AP TP 06/15/2007 14 Frame/Steel/Bolting/Welding CO TP 06/15/2007 24 Rough/Topout . CO TP 06/15/2007 34 Rough Electric CO TP 06/13/2007 17 Interior Lath/Drywall PA TP 06/05/2007 14 Frame/Steel/Bolting/Welding AP TP 06/05/2007 34 Rough Electric AP TP 06/05/2007 44 Rough/Ducts/Dampers AP TP 06/01/2007 44 Rough/Ducts/Dampers AP TP 06/01/2007 84 Rough Combo ' PI TP 05/30/2007 14 Frame/Steel/Bolting/Welding AP TP 05/30/2007 23 Gas/Test/Repairs AP TP 05/30/2007 24 Rough/Topout AP TP 05/30/2007 34 Rough Electric. AP TP 05/30/2007 44 Rough/Ducts/Dampers AP TP 05/29/2007 14 Frame/Steel/Bolting/Welding PA TP 05/29/2007 34 Rough Electric PA TP 05/29/2007 44 Rough/Ducts/Dampers PA TP 05/24/2007 21 Underground/Under Floor NR TP 05/23/2007 14 Frame/Steel/Bolting/Welding AP TP 05/23/2007 44 Rough/Ducts/Dampers VAP TP 05/21/2007 14 Frame/Steel/Bolting/Welding AP TP 05/21/2007 34 Rough Electric AP TP 05/21/2007 44 Rough/Ducts/Dampers PI TP 05/18/2007 17 Interior Lath/Drywall PA TP 05/16/2007 14 Frame/Steel/Bolting/Welding CO TP 05/16/2007 17 Interior Lath/Drywall CO TP 05/16/2007 44 Rough/Ducts/Dampers CO TP 05/15/2007 14 Frame/Steel/Bolting/Welding CO TP 05/15/2007 17 Interior Lath/Drywall CO TP 05/15/2007 44 Rough/Ducts/Dampers NR TP 05/14/2007 13 Shear Panels/HD's WC TP 05/14/2007 14 Frame/Steel/Bolting/Welding AP TP 05/14/2007 34 Rough Electric AP TP 05/14/2007 44 Rough/Ducts/Dampers AP TP 05/11/2007 13 Shear Panels/HD's ' CA PD 05/11/2007 44 Rough/Ducts/Dampers CA PD 05/07/2007 14 Frame/Steel/Bolting/Welding NR TP 05/07/2007 17 Interior Lath/Drywall AP TP 05/02/2007 17 Interior Lath/Drywall AP TP 05/01/2007 17 Interior Lath/Drywall PA TP 04/26/2007 17 Interior Lath/Drywall PA TP 04/25/2007 14 Frame/Steel/Bolting/Welding PA TP 04/25/2007 17 Interior Lath/Drywall PA TP 04/24/2007 14 Frame/Steel/Bolting/Welding PA TP 04/23/2007 14 Frame/Steel/Bolting/Welding AP TP 04/23/2007 14 Frame/Steel/Bolting/Welding AP TP 04/23/2007 24 Rough/Topout AP TP 04/23/2007 34 Rough Electric AP TP Inspector Assignment TP CEIL LITES, 3RD FLR OPEN AREAS DUCTS, H.P.s, 3RD FLR OPEN AREAS 1ST FLR OFFICES W. END SUP GYP CEIL @ 2W FLR EMP LOBBY 2ND FLR DUCT PRE-WRAP N SIDE 3RD FLR CEIL (CONF.) HARD CEIL @ EMP. ENTY MED PSI TEST DRINK FOUNTAINS HARD CEIL @ EMP. ENTY EMP. ENTY LOBBY CARGO ELEV. RM. 2ND FLR HARD CEIL IN CORR CONF. 2ND FLR MECH. 2ND FLR 1ST FLR LOBBY SECT.. 2ND FLR DUCT PRE-WRAP S. HALF N/COMP. 1ST FLR 2ND FLR 2ND FLR INT. WALLS 2ND FLR MISC. 2ND FLR MISC. AREAS 2ND FLR HARD CEILS 2ND FLR MISC. AREAS 2ND FLR WALLS 2ND FLR RESTROOM 2 & 3 FLR PMTER FURRED WALLS City of Carlsbad Bldg Inspection Request For: 08/29/2007 Permit* CB063273 04/19/2007 14 Frame/Steel/Bolting/Welding AP TP 04/19/2007 34 Rough Electric AP TP 04/16/2007 14 Frame/Steel/Bolting/Welding WC TP 04/16/2007 16 Insulation PA TP 04/12/2007 17 Interior Lath/Drywall AP TP 04/10/2007 14 Frame/Steel/Bolting/Welding AP TP 04/10/2007 24 Rough/Topout WC TP 04/10/2007 34 Rough Electric AP TP 04/10/2007 44 Rough/Ducts/Dampers PA TP 04/09/2007 14 Frame/Steel/Bolting/Welding AP TP 04/09/2007 24 Rough/Topout AP TP 04/09/2007 34 Rough Electric AP TP 04/09/2007 44 Rough/Ducts/Dampers WC TP 04/05/2007 14 Frame/Steel/Bolting/Welding AP TP 04/05/2007 17 Interior Lath/Drywall WC TP 04/02/2007 14 Frame/Steel/Bolting/Welding PA TP Inspector Assignment: TP 2ND FLR W. HALF, NO PLUMB. WALLS E. STAIR ENCL CEIL 3RD FLR INT. WALLS 3RD FLR INT. WALLS DUCT PRE WRAP S. SIDE 3RD FLR 3RD FLR E. HALF WALLS RESTRMS, BRK RM. 3RD FLR 3RD FLR E. HALF WALLS 2 & 3 RD FLR MECH SHAFTS / SHAFT WALLS) 1 IN CORE SECT. EsGil Corporation _y """ * . In (Partnership with government for Quitting Safety 4 DATE: December 21, 2O06 a APPLICANT a JURIS. JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 06-3273 SET: II PROJECT ADDRESS: 1265 Laurel Tree Ln. PROJECT NAME. 24 Hours Fitness CAC Facility - TI (office shell) 1X1 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: X] Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Sergio Azuela Enclosures: Esgil Corporation D GA D MB D EJ D PC 12/4 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 4 Fax (858) 560-1576 Carlsbad O6-3273 December 21, 20O6 VALUATION AND PLAN CHECK FEE Revised-12/20/06-S.A. JURISDICTION: Carlsbad PLAN CHECK NO.: 06-3273 PREPARED BY: Sergio Azuela DATE: December 21, 2006 BUILDING ADDRESS: 1265 Laurel Tree Ln. 24 Mrs. Fitness CAC Fac./Office TI BUILDING OCCUPANCY: B (TI only) TYPE OF CONSTRUCTION: I-FR BUILDING PORTION Office TI Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 49275 cb Valuation Multiplier 34.37 By Ordinance Reg. Mod. VALUE ($) 1,693,582 $2,780,000 1 693 582 $6,662.61 Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: Repetitive Fee Repeats Complete Review D Other i—i Hourly D Structural Only Hour* Esgil Plan Review Fee Comments: $4,170.76] $4,330.70 $2.911.84 $3,731.06 $2,508.66 Sheet 1 of 1 macvalue.doc EsGil Corporation In Partnership with government for <BuiCd~ing Safety DATE: December 1, 2006 O^EPUCANT JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 06-3273 SET: I PROJECT ADDRESS: 1265 Laurel Tree Ln. PROJECT NAME: 24 Hours Fitness CAC Facility - TI (office shell) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Interior Architects, Attn: Liliana Lenerman 3080 Bristol St., Costa Mesa, CA 92626 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Liliana Lenerman (v^) Telephoned (714) 754-1197 Date contacted: la. If foG? (by: [c- ) Fax #: (714) 754-1198 Mail u^Telephone .'Fax s In Person REMARKS: By: Sergio Azuela Enclosures: Esgil Corporation D GA D MB [X] EJ D PC 11/16 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 *• Fax (858) 560-1576 Carlsbad 06-3273 December 1, 2006 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 06-3273 OCCUPANCY: B TYPE OF CONSTRUCTION: I-F.R. ALLOWABLE FLOOR AREA: UL basic allowable area for B/I-FR SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: December 1, 2006 JURISDICTION: Carlsbad USE: Office (TI only) ACTUAL AREA: 49,275 SF (TI only) STORIES: 3 HEIGHT: OCCUPANT LOAD: DATE PLANS RECEIVED BY ESGIL CORPORATION: 11/16 PLAN REVIEWER: Sergio Azuela FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2001 CBC, which adopts the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw.dot Carlsbad 06-3273 December 1, 2OO6 1. Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. UBC Section 107.2 requires the Building Official to determine the total value of all construction work proposed under this permit. The value shall include all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment. Please provide the designer's or contractor's construction cost estimate of all work proposed. 3. Indicate the use of all spaces adjacent to the area being remodeled or improved. Please show it on plans for the areas on the East Side of line J at the second and third floors. 4. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 (see exceptions): a) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. • Please clearly show it on the plans for all applicable windows. See elevations on sheets A-7.5 to A-7.8. also there are some windows shown on the Floor Plans adjacent to doors: 234, 246, etc. b) , Individual fixed or operable panels, other than those locations described above, that meet all of the following conditions: i) Exposed area of an individual pane is greater than 9 square feet, and: ii) Exposed bottom edge is less than 18 inches above the floor, and: iii) Exposed top edge is greater than 36 inches above the floor, and: iv) One or more walking surfaces are within 36 inches horizontally of the plane of the glazing. • Please clearly show it on the plans for all applicable windows. See elevations on sheets A-7.5 to A-7.8. Carlsbad 06-3273 December 1, 2OO6 5. Note on the plans: "All interior finishes must comply with Chapter 8 of the UBC". Specify "Class II flame spread rating (minimum) for 1hr corridor." And "Class III flame spread rating (minimum) for ROOMS AND AREAS". 6. The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. See the attached correction sheet. Title 24. 7. In areas where the occupant load is at least 50, two exits are required. See Lunch Room. Table 10-A. Please note that the door 205 is located in the Kitchen and the required exits shall not pass through kitchens, store rooms, or spaces used for similar purposes. Section 1004.2.2. 8. Exit signs are required whenever two exits are required. Show all required exit sign locations. Section 1003.2.8.2. Door 215 is providing exit to both sides, therefore an exit sign shall be provided on each side of the door, adjacent to the leaf of the door which is opening to provide exit. 9. If exit signs are required, provide the following notes on the plans, per Section 1003.2.8.2: a) Exit signs shall be located as necessary to clearly indicate the direction of egress travel. b) Exit signs shall be readily visible from any direction of approach. 10. Show that exits are lighted with at least one foot candle at floor level. Section 1003.2.9.2. 11. Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge." In lieu of the above, in a Group B, F, M or S occupancies, you may note "Provide a sign on or near the exit door, reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." This signage is only allowed at the main exit. Section 1003.3.1.8. 12. Doors should not project more than 7 inches into the required corridor width when fully opened, nor more than one-half of the required corridor width when in any position. Section 1004.3. Please clearly show it on plans for doors 206 and 210B 13. All doors and gates, within the exit path from Group A occupancies to a public way, shall not be provided with latches or locks unless they are equipped with panic hardware. Section 1003.3.2.2. a) Please show it on plans for the existing doors at stairway enclosure, and at Entry Door on the First Floor on the North Side. 14. When two exits are required, dead end corridors are limited to 20 feet. Section 1004.2.6. Please show it on plans for the dead end adjacent to stairs and giving access to Conference Room 202. Carlsbad O6-3273 December 1, 2OO6 15. Corridors shall have interior door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes. Doors shall be maintained self-closing or be automatic closing by action of a smoke detector per Section 713.2. Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 1004.3.4.3.2.1. Please show it on plans for the doors at the existing Bathrooms. 16. If a room with an exhaust fan has a door opening into a rated corridor, show how makeup air will be provided to the room. The door cannot be undercut, nor can a louver in the door be provided. Section 1004.3.4.3.2.1. Please show it on plans for the doors at the existing Bathrooms. 17. Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor- ceilings and roof-ceilings shall be protected as required in UBC Sections 709 and 710." 18. Please see attached lists for electrical and energy corrections. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. * ELECTRICAL PLAN REVIEW 4 2002 NEC * PLAN REVIEWER: Morteza Beheshti 19. All electrical sheets of the plans are required to be signed by the California licensed engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. Business and Professions Code. Carlsbad O6-3273 December 1, 2006 20. Please clarify panel and other equipment names for clarity. I.e., OP2 panels and T-OP2 transformers. 21. The #6 equipment ground wire specified are undersized for the 400 ampere overcurent device size(s). 22. Show or note on the plans the method used to limit fault currents on branch circuits. 23. Please show location of panel "L3C" and "TSR" transformer. 24. Show on the plan the location of the existing service. NEC 110.26, 230.2. 25. Please specify the required: Room power disconnecting means; A separate HVAC system; Listed equipment and fire resistant-walls floors and ceilings with protected openings for the "information technology equipment room". NEC 645.2. 26. Provide multiple switch light controls at lobby lighting shown on E6.1. The switches must be located within sight of the lights which they control. CBC Title 24, Sec 131 a-b 27. If utilizing a series-rated system, note on plans: "Overcurrent device enclosures will be identified as series-rated and labeled in accordance with NEC 110-22" and" The overcurrent devices shall be AIC rated per manufacturers, labeling of the electrical equipment". • ENERGY CONSERVATION 28. Please correct the number of 2'x4' luminaries to match the lighting plans. 29. Include all "Parts" of energy forms ENV-1-C and MECH-1-C onto the plans. Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. PLUMBING and MECHANICAL CORRECTIONS PLAN REVIEWER: Eric Jensen PLUMBING (2000 UNIFORM PLUMBING CODE) • The plumbing is fine as submitted. Carlsbad O6-3273 December 1, 2006 MECHANICAL (2000 UNIFORM MECHANICAL CODE) • The mechanical is fine as submitted. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 The following disabled access items are taken from the 2001 edition of California Building Code, Title 24. Per Section 101.17.11, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. NOTE: All Figures and Tables referenced in this checklist are printed in the California Building Code, Title 24. • REMODELS. ADDITIONS AND REPAIRS 1. When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B.2. These requirements apply as follows: a) The area of specific alteration, repair or addition must comply as "new" construction. MULTIPLE ACCOMMODATION SANITARY FACILITIES 2. Show or note, per Section 1115B.7.1.3 that the doors to the accessible water closet compartment will be equipped with a self closing device with: a) >34" clearance when located at the side of the compartment. Please revise the dimension shown on detail 10/A6.1. • DRINKING FOUNTAINS 3. Drinking fountains shall be accessible to individuals who use wheelchairs and to those who have difficulty bending or stooping. This can be accommodated by the use of "hi-low" fountains. Section 1117B.1.1. Carlsbad 06-3273 December 1, 2006 4. Note on the plans that the drinking fountain(s) will comply with all applicable Title 24 provisions (bubbler height, etc.). END OF DOCUMENT Carlsbad 06-3273 .December 1, 2006 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: O6-3273 PREPARED BY: Sergio Azuela DATE: December 1, 2006 BUILDING ADDRESS: 1265 Laurel Tree Ln. 24 Hrs. Fitness CAC Fac./Office TI BUILDING OCCUPANCY: B (TI only) TYPE OF CONSTRUCTION: I-FR BUILDING PORTION Office TI Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq. Ft.) 49275 cb RIHn Pprmit FPP hu Orrlinanrp *V Valuation Multiplier . 34.37 By Ordinance Reg. Mod. VALUE ($) 1,693,582 1,693,582 $4,479.75 Plan Check Fee by Ordinance Type of Review: Repetitive FeeRepeats Complete Review D Other r-1 Hourly D Structural Only Hour* Esgil Plan Review Fee Comments: $2,911.84 $2,508.66 Sheet 1 of 1 macvalue.doc Carlsbad O6-3273 December 1, 2006 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 06-3273 OCCUPANCY: B TYPE OF CONSTRUCTION: I-F.R.// ALLOWABLE FLOOR AREA: UL basic allowable area for B/I-FR SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: December 1, 2006 JURISDICTION: Carlsbad USE: Office (TI only) ACTUAL AREA: 49,275 SF (TI only) STORIES: 3 HEIGHT: OCCUPANT LOAD: DATE PLANS RECEIVED BY ESGIL CORPORATION: 11/16 PLAN REVIEWER: Sergio Azuela FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2001 CBC, which adopts the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list for a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)Bforw.dot Carlsbad 06-3273 December 1, 2006 1 . Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: - 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858)560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. UBC Section 107.2 requires the Building Official to determine the total value of all construction work proposed under this permit. The value shall include all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment. Please provide the designer's or contractor's construction cost estimate of all work proposed. 3. Indicate the use of all spaces adjacent to the area being remodeled or improved. Please show it on plans for the areas on the East Side of line J at the second and third floors. 4. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 (see exceptions): a) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. • Please clearly show it on the plans for ail applicable windows. See elevations on sheets A-7.5 to A-7.8. also there are some windows shown on the Floor Plans adjacent to doors: 234, 246, etc. b) Individual fixed or operable panels, other than those locations described above, that meet all of the following conditions: i) Exposed area of an individual pane is greater than 9 square feet, and: ii) Exposed bottom edge is less than 1 8 inches above the floor, and: iii) Exposed top edge is greater than 36 inches above the floor, and: iv) One or more walking surfaces are within 36 inches horizontally of the plane of the glazing. • Please clearly show it on the plans for all applicable windows. See elevations on sheets A-7.5 to A-7.8. A -7,5 Carlsbad O6-3273 December 1, 20O6 5. Note on the plans: "All interior finishes must comply with Chapter 8 of the UBC" Specify "Class II flame spread rating (minimum) for 1hr corridor." And "Class III flame spread rating (minimum) for ROOMS AND AREAS". &X&&C AN ~^ " 6. The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. See the attached correction sheet. Title 24. 7. In areas where the occupant load is at least 50, two exits are required. See Lunch Room. Table 10-A. Please note that the door 205 is located in the Kitchen and the required exits shall not pass through kitchens, store rooms, or spaces used for similar purposes. .Section 1004.2.2. f &{&&&. &H-7.2 \ A \~ •fettJM 205 fc HOf A KlTOfOl OtoOsefciN^ ffcdwt>6S) , Tffe 8. Exit signs are required whenever two exits are required. Show all required exit sign locations. Section 1003.2.8.2. Door 215 is providing exit to both sides, therefore an exit sign shall be provided on each side of the door, adjacent to the leaf of the door which is opening to provide exit. AUrf&» Oil 9. If exit signs are required, provide the following notes on the plans, per Section 1003.2.8.2: a) Exit signs shall be located as necessary to clearly indicate the direction of egress travel. b) Exit signs shall be readily visible from any direction of approach. 1 0. Show that exits are lighted with at least one foot candle at floor level. Section 1003.2.9.2. 1 1 . Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge." In lieu of the above, in a Group B, F, M or S occupancies, you may note "Provide a sign on or near the exit door, reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." This signage is only allowed at the main exit. Section 1003.3.1 .8. £Ht^T Al ~l ) 12. Doors should not project more than 7 inches into the required corridor width when fully opened, nor more than one-half of the required corridor width when in any position. Section 1004.3. Please clearly show it on plans for doors 206 and210B 13. All doors and gates, within the exit path from Group A occupancies to a public way, shall not be provided with latches or locks unless they are equipped with panic hardware^ Section 1003.3.2.2. a) Please show it on plans for the existing doors at stairway enclosure, and at Entry Door on the First Floor on the North Side.AH *&&*> *$\o ) A\-Z W?&& , A(-5 tw&l 14. When two exits are required, dead end corridors are limited to 20 feet. Section 1004.2.6. Please show it on plans for the dead end adjacent to stairs and giving access to Conference Room 202. "%&f\G>£l> C>U <=>ff£^f- AW~7.'2. Carlsbad 06-3273 December 1, 2006 1 5. Corridors shall have interior door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes. Doors shall be maintained self-closing or be automatic closing by action of a smoke detector per Section 713.2. Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 1004.3.4.3.2.1 . Please show it on plans for the doors at the existing Bathrooms. ^K^^T* Al -2. , V&( Wtf& #*? 16. If a room with an exhaust fan has a door opening into a rated corridor, show how makeup air will be provided to the room. The door cannot be undercut, nor can a louver in the door be provided. Section 1004.3.4.3.2.1 .Please show it on plans for the doors at the existing Bathrooms. && &A&&{ M&- 1 17. Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor- ceilings and roof-ceilings shall be protected as required in UBC Sections 709 and710." 18. Please see attached lists for electrical and energy corrections. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes O No CJ The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. • . * ELECTRICAL PLAN REVIEW * 2002NEC • PLAN REVIEWER: Morteza Beheshti 19. All electrical sheets of the plans are required to be signed by the California licensed engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. Business and Professions Code. Carlsbad O6-3273 December 1, 2006 "^ 20. Please clarify panel and other equipment names for clarity. I.e., OP2 panels and T-OP2 transformers. 21. The #6 equipment ground wire specified are undersized for the 400 ampere overcurent device size(s). 22. Show or note on the plans the method used to limit fault currents on branch circuits. s 23. Please show location of panel "L3C" and "TSR" transformer. 24. Show on the plan the location of the existing service. NEC 110.26, 230.2. 25. Please specify the required: Room power disconnecting means; A separate HVAC system; Listed equipment and fire resistant-walls floors and ceilings with protected openings for the "information technology equipment room". NEC 645.2. v. - 26. Provide multiple switch light controls at lobby lighting shown on E6.1. The switches must be located within sight of the lights which they control. CBC Title 24,Sec131a-b 27. If utilizing a series-rated system, note on plans: "Overcurrent device enclosures will be identified as series-rated and labeled in accordance with NEC 110-22" and" The overcurrent devices shall be AIC rated per manufacturers, labeling of the electrical equipment". • ENERGY CONSERVATION 28. Please correct the number of 2'x4' luminaries to match the lighting plans. 29. Include all "Parts" of energy forms ENV-1-C and MECH-1-C onto the plans. Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. PLUMBING and MECHANICAL CORRECTIONS PLAN REVIEWER: Eric Jensen PLUMBING (2000 UNIFORM PLUMBING CODE) ( -_ ... - • The plumbing is fine as submitted. * $8? Carlsbad 06-3273 December 1, 2006 MECHANICAL (2000 UNIFORM MECHANICAL CODE) • The mechanical is fine as submitted. O\L. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 The following disabled access items are taken from the 2001 edition of California Building Code, Title 24. Per Section 101.17.11, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. NOTE: All Figures and Tables referenced in this checklist are printed in the California Building Code, Title 24. • REMODELS. ADDITIONS AND REPAIRS 1. When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B.2. These requirements apply as follows: a) The area of specific alteration, repair or addition must comply as "new" construction. ok.. MULTIPLE ACCOMMODATION SANITARY FACILITIES 2. Show or note, per Section 1115B.7.1.3 that the doors to the accessible water closet compartment will be equipped with a self closing device with: a) >34" clearance when located at the side of the compartment. Please revise the dimension shown on detail 10/A6.1. &&& te&ffe&k \o ^ 14 • DRINKING FOUNTAINS 3. Drinking fountains shall be accessible to individuals who use wheelchairs and to those who have difficulty bending or stooping. This can be accommodated by the use of "hi-low" fountains. Section 11178.1.1. <66£ tiOflg Q <2»M. Carlsbad O6-3273 December 1, 20O6 4. ' a,, app)icaWe °* END OF DOCUMENT 24 Hour Fitness Plan File No. 05-3525 PLAN REVIEW SHEET FOR PLAN CHECK - COMMENTS 1 . Show that exits are lifted with at least one foot candle at floor level. 2. All electrical sheets to be signed by engineer 3. Please clarity panel and other equipment names for clarity, i.e., OP2. panels and T- OP2 transformers 4. The #6 equipment ground wire specified are undersized for the 400 ampere overcurrent device size(s). 5. Show or note on plans the method used to limit fault currents on branch circuits. 6. Please show location of panel 'L3C' and TSR' transformer. 7. Show on the plan the location of the existing service. NEC 110.26, 230.2. 8. Please specify the required: Room power disconnecting means, a separate HVAC system, Listed equipment and fire resistant- walls, floors and ceilings with protected openings for the "information technology equipment room". NEC 645.2. 9. Provide multiple switch light controls at lobby lighting shown on E6.1 The switches must be located within sight of the lights . which they control. CBC Title 24, Sec 131 a- b. 10. If utilizing a series-rated system, note on plans: "Overcurrent devices enclosures will be identified as series-rated and labeled in accordance with NEC 1 10-22" and 'The overcurrent devices shall be AIC rated per manufacturers labeling of the electrical equipment." 1 1 . Please correct the number of 2'x4' luminaries to match the lighting plans. RESPONSES EB fixtures shown on lighting plan to provide 90minutes of egress lighting. This will provide 1 foot candle average throughout the exiting path. E2.1 and E2.2 All electrical sheets will be signed All equipment is shown on plans. E3.1 and E3.2 Revised on sheet E4.1 Shown on plans. Sheet E4.1 Added to plans. Sheet E3.2 Shown on plans. Sheet E4.1 EPO arid-Main shown for room. Sheet E3.2 Added to plans. Sheet E6.1 Note added. Sheet E4.1 Revised. \ ' " . City of Carlsbad Public Works T- Eng inee ring BUILDING PLANCHECK CHECKLIST DATE: BUILDING ADDRESS: PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER: / <& &> $ PLANCHECK NO.: CB (£?^ - 3^ ?3 ^rt~*< ^ EST. VALUE: ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. D A Right-of-Way permit is .required prior to construction of the following improvements: DENIAL Please marked or sp codes specif! ,nd applicable By: By: By: iched report of deficiencies :e necessary corrections to plans for compliance with applicable standards. Submit corrected plans and/or r review. Only thetions Date: .Date: Date: *y. y/ FOR OFFICIAL USE ONLY iNEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: 'Vy-v^'-.G.';•-•-..:; ••,•-,:.;"•: ^-Da'te-v-: ATTACHMENTS D Dedication Application D Dedication Checklist D Improvement Application D Improvement Checklist D Neighborhood Improvement Agreement D Grading Permit Application D Grading Submittal Checklist D Right-of-Way Permit Application Q Right-of-Way Permit Submittal Checklist and Information Sheet ENGINEERING DEPT. CONTACT PERSON Name: KATHLEEN M. FARMER City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad. CA 92008 Phone: (760) 602-2741 NOTE: If there are retaining walls associated with your project, please check with the Building Department if these walls need to be pulled by separate RETAINING WALL PERMIT. A-4 , CA 9200(8-7314 • (760) 602-2720 • FAX (760) 608*8S62 BUILDING PLANCHECK CHECKLIST D D SITE PLAN 1. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow B. Existing & Proposed Structures C. Existing Street Improvements D. Property Lines (show all dimensions) E. Easements 2. Show on site plan: F. Right-of-Way Width & Adjacent Streets G. Driveway widths H. Existing or proposed sewer lateral I. Existing or proposed water service J. Existing or proposed irrigation service A. Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. 3. Include on title sheet: A. Site address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION Show all existing use of SF and new proposed use of SF. Example: Tenant Improvement for 3500 SF of warehouse to 3500 SF of office. F:\FarmertKathy\MASTERS\Building Plancheck Cklst Form (Generic).doc BUILDING PLANCHECK CHECKLIST ST1 D ,ND RD3' D DISCRETIONARY APPROVAL COMPLIANCE 4a. Project does not comply with the following Engineering Conditions of approval for Project No._ D D D 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS D D 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 17.000 . pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: •_ Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 %" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by:Date: n n IMPROVEMENT REQUIREMENTS 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 82.000 . pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the F:\Fanmer\KATHYlMASTERS\Buildinfl Planctwck Cklst Forni (Generic).doc 3 BUILDING PLANCHECK CHECKLIST 1ST D ND2 D RD3' D D D D checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by:Date: 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $ 400.00 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: D D D D D 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Neighborhood Improvement Agreement completed by: Date: 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. D D D D D GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill import, export and remedial). This information must be included on the plans. 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be, submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by:Date: D D 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) F:\Farmer\KATHY\MASTERS\BuiWina Planclwck Cklst Form (Genericj.doc Rev. 7/14/00 BUILDING PLANCHECK CHECKLIST ..ST D D D 7d. No Grading Permit required. D D D 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS D D D 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: __ _ D D D 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: Date: NPDES PERMIT D D D 10a. Storm Water Requirements Applicability Checklist Completed. C3 L~H O 10b. Priority Determination and compliance: D Priority Project D Subject to Standard Permanent Storm Water BMP's D Exempt D D 11- Jd Required fees are attached D No fees required WATER METER REVIEW D D D 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. • All single family dwelling units received "standard" 1" service with 5/8" service. F:\Farmer\KATHYMWASTERS\Building Planctieck Cklst Form (Generic) doc f- Rev 7/14/00 BUILDING PLANCHECK CHECKLIST |ST -.ND gRD D D • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. • Maximum service and meter size is a 2" service with a 2" meter. • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated . demand, (manifolds are considered on case by case basis to limit multiple trenching into the street). 12b. Irrigation Use (where recycled water is not available) ^ All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: 1. If the project is a newer development (newer than 1998), check the recent . improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: STA 1 +00 Install 2" service and 1.5: meter (estimated 100 gpm) 2.If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection 3.. In, general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water F:\FarmehKathy\MASTERS\Buildlng Plancheck Ckist Form (Generic).doc BUILDING PLANCHECK CHECKLIST 1 £— O service boundary, the City intends on switching these irrigation ' services/meters to a new recycled water line in the future. CD D C 12c. Irrigation Use (where recycled water is available) 1. Recycled water meters are sized the same as the irrigation meter above. 2. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. [U D D 13. Additional Comments: F:\Farmer\Kalhy\MASTERS\Buiiding Plancheck Cklst Form (Generic).doc ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D D Estimate based on unconfirmed information from applicant. Calculation based on btfll3)ing plan/h)#ck plan submittal. Address:Bldg. Permit No. <Qb - Prepared by:Checked by:Date: EDU CALCULATIONS: List types and square footages for all uses. Types of Use: &J\ Sq. Ft./Units: w Types of Use: Sq. Ft./Units: APT CALCULATIONS: List types and square footages for all uses. Types of Use: rff). Sq. Ft./Units: ^^ Z-?Jw-p Types of Use: _^Sq. Ft./Units: EDU's: EDU's: ADT's: ADT's: II. FEES REQUIRED: WITHIN CFD: D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO D 1. PARK-IN-LIEU FEE FEE/UNIT: PARK AREA & #: X NO. UNITS: U 2. TRAFFIC IMPACT FEE<-^s )T'sA)NITS: D 3. BRIDGE AND THOROUGHFARE FEE (DIST. #1 ADT's/UNITS: "7 3 / X /TEE//DT: DIST. #3 D 4. FACILITIES MANAGEMENT FEE UNIT/SQ.FT.: D 5. SEWER FEE EDU's: /"?'$ ^- BENEFIT AREA: ___ _ EDU's: ZONE: -> X FEE/SQ.FT./UNIT:= $ FEE/EDU, D 6. SEWER LATERAL ($2,500) D 7. DRAINAGE FEES PLDA ACRES: = $_ = $ jtth HIGH /LOW FEE/AC:= $ D 8. POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION 1 of 2 (Ob n/l j r?- PLANNING/ENGINEERING APPROVALS PERMIT NUMBER 1/17/06 RESIDENTIAL RESIDENTIAL ADDITION MINOR «$10.000.00) f OTHER PLAZA CAMINO REAL f • ^, CARLSBAD COMPANY STORES V1LLAGIFAJRE COMPUn OFFICE BUILDING DATB OATB Carlsbad Fire Department Plan Review Requirements Category: TI, INDUST Date of Report: 12-11-2006 Name: Address: Reviewed hy Permit #: CB063273 Job Name: 24 HOUR FITNESS-49,275 SF TI Job Address: 1265 LAUREL TREE LN CBAD ttttiQMltUE3C£^_Xh£jLtem you have submitted for review is incomplete. At this ti adequately conduct a review to determine cnmnr^ review carefully all comment"rltj^ft^Ji^MiiiM|'llli11 I'l'I'IIV'i'i! lin in i i n plans and/or specifications, with change^cIoTRH J*liiBWfflCeT8n?view and approval. Conditions: Cond: CON0001769 [MET] Concur with Esgil's exiting comments. Entry: 12/11/2006 By: MS Action: AP -4, X ~> tf pi" K _l tf> LUUi fc Qo: - LU32 —J< L <-J CO LU 37U) W O I- < 5x m (C ^ o -£ xS jC, rr 3 0 0 04-26-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No:PCR07062 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: Applicant: FRIAR GARY 714437-3467 1265 LAUREL TREE LN CBAD PCR 2120402500 Lot#: $0.00 Construction Type: CB06-3273 24 HOUR FITNESS REVISE CORE EXITING SYSTEM 0 NEW Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: ISSUED 03/22/2007 MDP 04/26/2007 04/26/2007 Owner: ASCENT BILTMORE CARLSBAD L L C 111 W MON ROE ST #1111 PHOENIX AZ 85003 Plan Check Revision Fee Additional Fees $360.00 $0.00 Total Fees:$360.00 Total Payments To Date:$360.00 Balance Due:$0.00 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO. EST. VAL._J Plan Ck. Deposit Validated By_ Date O 7- __ Address (include Bldg/Suite #)Business Name (at this address) Legal Description Lot No.Subdivision Name/Number Unit No.Phase No.Total # of units Assessor's Parcel # •Existing Use Proposed Use Description of Work SQ.FT.#of Stories # of Bedrooms # of Bathrooms Address City ^la|f{2p _M TeleptonMf ifQiGantraotar,' <?Q AgetitJorZContrsctorf ?GKOwn«r." Q Agent for1 Owner - ^'^7^'^T^^W^Si^i^ Name Fax # Name Address City State/Zip Telephone # Name City State/Zip Telephone #Address l" (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code! or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031 .5 by any applicant for a permit subjects the applicant to a civil penalty Of not more than five hundred dollars ($500)). Name Address State License H . License Class City State/Zip Telephone * City Business License # Designer Name Address State License it City State/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: ["") I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100) OR LESS) Q CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE , DATE . lllBBvfN'iR*BUILDER DECLARATION *:»''"'' V1 H "*''*' * V « "V * -I l<»%^^ « ^^Mi^"^?,***'*4**'*^ "i!^li|»^»'tM*5Hl/?*ik"fi*Sf''iff* *''i'l^,'J I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his Own employees, provided that such improvements are not intended or offered for sale. If, however, the building or Improvement is sold within One year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to ah Owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). , Q I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES [~1NO 2. I (have / have hot) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): . - . ,__^ . . . . . 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): . . „ , ; . DATEPROPERTY OWNER SIGNATURE __ ____ _ _ PSllIIl&HissECTio^dB:^^ >'v '.'.(«, *!,*' " ,, rjfcid' ;n. j > .r-^MV^it, Is the applicant or future building Occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES tD NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES CD N0 Is the facility to be constructed within 1 ,000 feet Of the outer boundary of a school site? O YES CD NO IF ANY OF THE ANSWERS ARE YES. A FINAL CERTIFICATE 0*F OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(11 Civil Code). LENDER'S NAME LENDER'S ADDRESS ', »«i( i * t r-* ' , „?»$£•, \ i7 I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE T6 SAVE. INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: Ah OSHA permit is required for excavations over 5'6" deep and demolition or construction of structures Over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void il the building or work authorized t>y such permit is not commenced vvjjJiinjWO days from the datejjUucbjjermit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is cofhrfiencedJoi^apenOd of 180 daysjgctflioiv!06.4.4U?H[orm Building Code). APPLICANT'S SIGNATURE YELLOW: Applicant PINK: Finance DATE f EsGil Corporation In (partnership with government for (RuiCding Safety DATE: April 18, 2OO7 a APPLICANT JURISDICTION: Carlsbad TTFLAN REVIEWER Q FILE PLAN CHECK NO.: 06-3273 (PCR07-62) SET: III REV PROJECT ADDRESS: 1265 Laurel Tree Ln. PROJECT NAME: 24 Hr FitnesS CAC Facility - Plan Changes XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: XI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: •_ Telephone $t Date contacted: /)//v\(fcY:^ $&&'' 0^— |0/^a£%: 714-754-1198 Mail Telephone/ 'Fax In Person I X3 REMARKS: (Ay City to verify that the intermediate landing between the second and third floors at the existing stairs adjacent to Conference Room 202, comply with the minimum dimensions required by the Code. B. All sheets of plans shall be signed by the architect of record. By: Sergio Azuela Enclosures: Esgil Corporation • -,..., Q^EJ ' D PC "";':'(J47l2 EsGil Corporation In Partnership with government for (Building Safety DATE: April 10, 2007 a APPLICANT " JURISDICTION: Carlsbad /OPLAN REVIEWER a FILE PLAN CHECK NO.: 06-3273 (PCR07-62) SET: II REV PROJECT ADDRESS: 1265 Laurel Tree Ln. PROJECT NAME: 24 Hr FitnesS CAC Facility - Plan Changes The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. Al The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Gary Friar 3080 Bristol St., Costa Mesa, CA 92626 I | Esgil Corporation staff did not advise the applicant that the plan check has been completed. XJ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Garv Friar Telephoned. (714)437-3467 Date contacted: wW (by: £/). Fax #: 714-754-1198 ^ -sMail Telephone Fax-/ In Person REMARKS: By: Sergio Azuela Enclosures: Esgil Corporation D GA D MB D EJ D PC 04/03 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad PCRO7-62 April 1O, 2007 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: PCRO7-62 PROJECT ADDRESS: 1265 Laurel Tree Ln. SET: II (REV06-3273) DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 04/03 April 10, 2007 REVIEWED BY: Sergio Azuela ___^ FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. . 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo Carlsbad PCR07-62 April 10, 2007 1. Provide a complete list of all proposed plan changes, including the following: a) A brief description of each one of the proposed plan changes. i) The sheet of plans provided for this recheck included three areas clouded. Please provide a brief description for each one of the proposed plan changes included in these clouded areas. b) The sheet or sheets of plans which are modified because each one of the proposed plan changes. i) It appear that the Door Schedule and also a new sheets A8,2 and A8.1 will be required for the new proposed changes and details. c) The identification number used to identify each one of the proposed plan changes on the plans. i) Please clarify if the new proposed plan changes are identified on the plans with a A number 5. 2. It appears that because one of the proposed plan changes the stairway landings on the North Side of the stairway enclosure adjacent to Line J is being reduced. Please clearly show on the plans full compliance of the stairway landings, which are impacted. Additional corrections may follow. a) The previously approved plans File # 063273 are showing the indicated change on the stairway landings, as a result of one of the proposed plan changes. Original correction is still applicable. 3. Some new details were included in the sheets A1-2 and A1-3, which were not included within the new plans, nor were shown on the previously approved plans. See 17/A8-2, 13/A8-4 and 20//A8-1. Please provide all applicable new details. Additional corrections may follow. a) Please provide the new proposed details on the new sheets A8.2 and A8.1. All sheets of the plans are required to be signed by the California licensed architect or engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. Business and Professions Code. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. Carlsbad PCRO7-62 April 1O, 2OO7 JURISDICTION: Carlsbad VALUATION AND PLAN CHECK FEE PLAN CHECK NO.: PCR07-62 PREPARED'BY: Sergio Azuela DATE: April 1O, 2007 BUILDING ADDRESS: 1265 Laurel Tree Ln. 24 Hr Fitness CAC Facmty - Plan Changes BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: 1-FR BUILDING PORTION Time Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq.Ft.) cb Blda. Permit FPP hu OrHinani-p 'W Valuation Multiplier By Ordinance Reg. Mod. VALUE ($) Plan Check Fee by Ordinance $360.00 Type of Review: D Repetitive FeeRepeats D Complete Review D Other m Hourly Structural Only Hours Esgil Plan Review Fee $288.00 * Based on hourly rate Comments: Sheet 1 of 1 macvalue.doc ( v EsGil Corporation In <Partnersfiip with (government for (Buififing Safety DATE: March 3O, 2OO7 Q/APPLICANT W^JURIS, JURISDICTION: Carlsbad a PLAN REVIEWER / N a FILE PLAN CHECK NO.: (£CR07-62j 3£- 337J SET: I (REVO6-3273) PROJECT ADDRESS: 1265 Laurel Tree Ln. PROJECT NAME: 24 Hrs Fitnes CAC Facility - Plan Changes The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has Gary Friar 3080 Bristol St., Costa Mesa, CA 92626 Esgil Corporation staff did not advise the applicant that the plan check has been completed. IXI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: .Gar^riaruAAj Telephone #: (714) 437-3467 Date contacted: ^\w( (by:p ) Fax #:^<yMaik^""Telephone S Fax ^ In Person REMARKS: ~ By: Sergio Azuela __ Enclosures:•r'S'iBSl^jEsgil Corporation 's< D GA D MB D EJ D PC 3/26 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4- Fax (858) 560-1576 Carlsbad PCRO7-62 t March 3O, 2O07 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 1265 Laurel Tree Ln. DATE PLAN RECEIVED BY ESGIL CORPORATION: 3/26 REVIEWED BY: Sergio Azuela PLAN CHECK NO.: PCRO7-62 DATE REVIEW COMPLETED: March 30, 2007 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? Yes a No Carlsbad PCRO7-62 i March 30, 2007 1. Provide a complete list of all proposed plan changes, including the following: a) A brief description of each one of the proposed plan changes. b) The sheet or sheets of plans which are modified because each one of the proposed plan changes. c) The identification number used to identify each one of the proposed plan changes on the plans. d) Please note that the required list of changes is essential for the plan checking of the proposed plan changes. 2. It appears that because one of the proposed plan changes the stairway landings on the North Side of the stairway enclosure adjacent to Line J is being reduced. Please clearly show on the plans full compliance of the stairway landings, which are impacted. Additional corrections may follow. 3. Some new details were included in the sheets A1-2 and A1-3, which were not included within the new plans, nor were shown on the previously approved plans. See 17/A8-2, 13/A8-4 and 20//A8-1. Please provide all applicable new details. Additional corrections may follow. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. Carlsbad PCR07-62 March 3O, 20O7 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: PCR07-62 PREPARED BY: Sergio Azuela DATE: March 30, 2007 BUILDING ADDRESS: 1265 Laurel Tree Ln. 24 Hrs Fitnes/Plan Changes BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: I BUILDING PORTION Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) Rlrin Pprmit FPP h\/ OrHinanrp ^T Valuation Multiplier #N/A Reg. Mod. VALUE ($) 7£r9 ^r>(' ^#N^ Plan Check Fee by Ordinance "v #N/A Type of Review: l~l Repetitive Fee Repeats Complete Review D Other (—, Hourly fj Structural Only Hour* Esgil Plan Review Fee #N/A Comments: ESGIL Fees to follow Sheet 1 of 1 macvalue.doc Carlsbad Fire Department BUILDING COPY Plan Review Requirements Category: PCR, Date of Report: 04-04-2007 Name: Address: Reviewed by: Permit #: PCR07062 Job Name: 24 HOUR FITNESS Job Address: 1265 LAUREL TREE LN CBAD JfljCflMPMrlK The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CQN0001980 [MET], THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 04/04/2007 By: GR Action: AP a UioK*»$IOCtn S?5cg55i<aSai r, T ^^\r^-o ^?/^/-\ h^o c< rv ^> <v ^^.