HomeMy WebLinkAbout1265 LAUREL TREE LN; ; CB063273; Permit03-16-2007
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No: CB063273
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
1265 LAUREL TREE LN CBAD
Tl Sub Type:
2120402500 Lot#:
$2,780,000.00 Construction Type:
Reference #:
24 HOUR FITNESS-49,275 SF Tl
SHELL TO OFFICE
INDUST
0
IFR
Applicant:
LILIANA LEDERMAN
STE 105
3080 BRISTOL ST
COSTA MESA 92626
7147541197
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Plan Check*:
Owner:
ASCENT BILTMORE CARLSBAD L L C
111 WMON ROE ST #1111
PHOENIX AZ 85003
ISSUED
11/15/2006
LSM
03/16/2007
03/16/2007
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'l Pot. Water Con. Fee
Reel. Water Con. Fee
$6,662.61 Meter Size
$0.00 Add'l Reel. Water Con. Fee
$4,330.70 Meter Fee
$0.00 SDCWA Fee
$0.00 CFD Payoff Fee
$583.80 PFF (3105540)
$0.00 PFF (4305540)
$0.00 License Tax (3104193)
$0.00 License Tax (4304193)
$200,269.00 Traffic Impact Fee (3105541)
$0.00 Traffic Impact Fee (4305541)
$0.00 PLUMBING TOTAL
$0.00 ELECTRICAL TOTAL
$0.00 MECHANICAL TOTAL
$0.00 Master Drainage Fee
Sewer Fee
$0.00 Redev Parking Fee
$0.00 Additional Fees
HMP Fee
TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$50,596.00
$0.00
$0.00
$0.00
$21,431.00
$0.00
$356.00
$812.00
$537.00
. $0.00
$18,343.44
$0.00
$0.00
??
$303,921.55
Total Fees:$303,921.55 Total Payments To Date:$303,921.55 Balance Due:$0.00
iUILDING PLANS
J/L IN STORAGE
^ATTACHED
Inspector:
FINAL APPROVAL
Date:Clearance:
NOTICE: Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
ERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1 635 Faraday Ave., Carlsbad CA 92008
1, PROJECT INFORMATION
FOR OFFICE USE ONLY
PLAN CHECK NO.
EST. VAL.
PlanCk. Deposit.
Validated By
Date
17-^4
pluda Bldg/Suite^
J^
Legal Description . . Lot No. Subdivision Name/Number UntfNo."tof ^ of EAMGfto ^bfojbA H*fr#~I Existing Use .T «'
UnKNp. _ Phase No.g£s
Assessor's Parcel #50^5 Parcel # _l-CfiO-£<5 Existing Use •
vMJAMrSQ.FT.Description of Work
i^KRf Tm*&7v#weiK>r ^i&ju-ip
2, CONTACT PERSON (if different from applicant)
# of Stories # of Bathrooms
46,^75«f 5>S7S£fe£
Name Fax*
Name " " Address City State/Zip Telep'h
5, CQ8TOA(npR-COMPANY NAME '.'-.'" \ -
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance,
also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with
Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]).
L. U £ A.:* t>i <!T<j.Co. fV7O 1-iAiOA lAsT/> j^a SA»>»/>
Name
State License #
s\~~l st f\~t
JLO /ZQf
Address
License Class A f
City State/Zip
City'Business License # _
Telei
Designer Name
State License #
Address City State/Zip Telephone #
Workers' Compensation Declaration: I hereby^affirm under penalty of perjury one of the following declarations:
D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work
for which this permit is issued..
D I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My
worker's compensation insurance carrier and policy number are:
Insurance Company f^ATlGiuA\ \)/\.itt^ fi'-fi-Tfe Policy No.-»ir>-»•'* **Expiration Date_
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to
become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand
I dollars($100,000), in addition to the cost of compensation, damages are provided for in Section 3706 of the Labor Code, interest and attorney's fees.
^SIGNATURE ' ^/vyx^^w*^— , DATE 3~I<.~O~7
7, QWN£R*UttDER DECtARATfOS ' ""_ " , . ' ^ s
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
D I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or
through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of
completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's
License Law). ' •
D I am exempt under Section', : Business and Professions Code for this reason: :
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES D NO
2. I (have/have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number/ contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number /
/ontractors license number): ' ; ; .
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work):
PROPERTY OWNER SIGNATURE _DATE
WHITE: File YELLOW: Applicant PINK: Finance
RMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad CA 92008
Page 2 of 2
COMPLETE THIS SECTION TOR WON-RES/OEWTML BUILDING PERMITS ONLY *
Is the applicant or future building occupant required to submit a business plan, acutely hazardous material^ registration for or risk management and prevention program under
Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES BTNO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES IzNO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
8. CONSTRUCTION LiMOIN6ASi*<CY j
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code).
LENDER'S NAME "_ : ; LENDER'S ADDRESS
9, APRICAW CERTIFICATION ,
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City
ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND
EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. .
OSHA: An OSHA permit is required for excavations of 5'0" deep and demolition or construction of structures over 3 stories in height. .
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized
by such permit is not commenced within 1 sAitays from the data of suchoermit or if the building or work authorized by such permit is suspended or abandoned at any time after
the work is commenced for a periodoTTSp aeys'JSectionjUje.44 Uniform Building Code).
APPLICANT'S SIGNATURE/ I M/f/l/J/f/tA DVIA^ - DATE
WHITE: File YELLOW: Applicant PINK: Finance
City of Carlsbad
Final Building Inspection
Dept: Building Engineering Planning CMWD St Lite Fire
Plan Check #:
Permit #:
Project Name:
Address:
Contact Person:
Sewer Dist:
CB063273
24 HOUR FITNESS-49,275 SF Tl
SHELL TO OFFICE
1265 LAUREL TREE LN
Phone:
CA Water Dist: CA
Lot:
Date: 08/13/2007
Permit Type: Tl
Sub Type: INDUST
0
Inspected
By:
Inspected
By:
Inspected
By:_
Date
Inspected:
Date
Inspected:
Date
Inspected:
fafe.. ApprovedX-
.Approved:
. Approved:
Disapproved:
Disapproved:
Disapproved:
Comments:
City of Carlsbad Bldg Inspection Request
For: 08/29/2007
Permit* CB063273
Title: 24 HOUR FITNESS-49,275 SF Tj
Description: SHELL TO OFFICE
Inspector Assignment: TP
Type:TI Sub Type: INDUST
Job Address: 1265 LAUREL TREE LN
Suite: lot: 0
Location:/.
APPLICANT LILIANA LEDERMAN
Owner: ASCENT BILTMORE CARLSBAD L L C
\
Remarks:
Phone:
Inspector:
Total Time:
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By: NA
Entered By: CHRISTINE
Act Comments
Comments/Notices/Holds
CV070670
PCR07009
PCR07049
PCR07062
PCR07069
Associated PCRs/CVs Original PC#
CLOSED Z- BANNER;
BILTMORE PACIFICA STEEL WEB; JOISTS-DEFERRED SUBMITTAL
BILTMORE PACIFICA- DEFFERED; CURTAIN WALLS SUBMITTAL
24 HOUR FITNESS; REVISE CORE EXITING SYSTEM
24 HR FITNESS CHANGES TO ELEC; &LAUNDRY RMS.RELOCATE WORK&MECH Rl>
ISSUED
ISSUED
ISSUED
ISSUED
Inspection History
Date Description Act Insp
08/09/2007 89 Final Combo CO TP
07/19/2007 84 Rough Combo NR MC
07/17/2007 84 Rough Combo PA MC
07/11/2007 84 Rough Combo PA PC
07/05/2007 84 Rough Combo AP TP
07/02/2007 84 Rough Combo^- PA TP
06/29/2007 14 Frame/Steel/Bolting/Welding PA TP
06/28/2007 14 Frame/Steel/Bolting/Welding PA TP
Comments
) • ' '
COMPLETE ALL WORK INCLUDING FIRE CAULKING,
SEE CARD ON SITE FOR ROOMS
2ND FLR CORRIDOR
T-CEIL 2ND FLR. LG. RMS CEIL LITES 2ND FLR LG. RMS-
DUCTS,HP(INCL FIREWRAP DUCT)
T-CEIL 2ND FLR OFFICES
2ND FLR PMTR CEIL ROOMS
T-CEIL 3RD FLR OPEN AREAS
City of Carlsbad Bldg Inspection Request
For: 08/29/2007
Permit* CB063273
06/28/2007 34 Rough Electric PA TP
06/28/2007 44 Rough/Ducts/Dampers AP TP
06/15/2007 14 Frame/Steel/Bolting/Welding CO TP
06/15/2007 24 Rough/Topout . CO TP
06/15/2007 34 Rough Electric CO TP
06/13/2007 17 Interior Lath/Drywall PA TP
06/05/2007 14 Frame/Steel/Bolting/Welding AP TP
06/05/2007 34 Rough Electric AP TP
06/05/2007 44 Rough/Ducts/Dampers AP TP
06/01/2007 44 Rough/Ducts/Dampers AP TP
06/01/2007 84 Rough Combo ' PI TP
05/30/2007 14 Frame/Steel/Bolting/Welding AP TP
05/30/2007 23 Gas/Test/Repairs AP TP
05/30/2007 24 Rough/Topout AP TP
05/30/2007 34 Rough Electric. AP TP
05/30/2007 44 Rough/Ducts/Dampers AP TP
05/29/2007 14 Frame/Steel/Bolting/Welding PA TP
05/29/2007 34 Rough Electric PA TP
05/29/2007 44 Rough/Ducts/Dampers PA TP
05/24/2007 21 Underground/Under Floor NR TP
05/23/2007 14 Frame/Steel/Bolting/Welding AP TP
05/23/2007 44 Rough/Ducts/Dampers VAP TP
05/21/2007 14 Frame/Steel/Bolting/Welding AP TP
05/21/2007 34 Rough Electric AP TP
05/21/2007 44 Rough/Ducts/Dampers PI TP
05/18/2007 17 Interior Lath/Drywall PA TP
05/16/2007 14 Frame/Steel/Bolting/Welding CO TP
05/16/2007 17 Interior Lath/Drywall CO TP
05/16/2007 44 Rough/Ducts/Dampers CO TP
05/15/2007 14 Frame/Steel/Bolting/Welding CO TP
05/15/2007 17 Interior Lath/Drywall CO TP
05/15/2007 44 Rough/Ducts/Dampers NR TP
05/14/2007 13 Shear Panels/HD's WC TP
05/14/2007 14 Frame/Steel/Bolting/Welding AP TP
05/14/2007 34 Rough Electric AP TP
05/14/2007 44 Rough/Ducts/Dampers AP TP
05/11/2007 13 Shear Panels/HD's ' CA PD
05/11/2007 44 Rough/Ducts/Dampers CA PD
05/07/2007 14 Frame/Steel/Bolting/Welding NR TP
05/07/2007 17 Interior Lath/Drywall AP TP
05/02/2007 17 Interior Lath/Drywall AP TP
05/01/2007 17 Interior Lath/Drywall PA TP
04/26/2007 17 Interior Lath/Drywall PA TP
04/25/2007 14 Frame/Steel/Bolting/Welding PA TP
04/25/2007 17 Interior Lath/Drywall PA TP
04/24/2007 14 Frame/Steel/Bolting/Welding PA TP
04/23/2007 14 Frame/Steel/Bolting/Welding AP TP
04/23/2007 14 Frame/Steel/Bolting/Welding AP TP
04/23/2007 24 Rough/Topout AP TP
04/23/2007 34 Rough Electric AP TP
Inspector Assignment TP
CEIL LITES, 3RD FLR OPEN AREAS
DUCTS, H.P.s, 3RD FLR OPEN AREAS
1ST FLR OFFICES W. END
SUP GYP CEIL @ 2W FLR EMP LOBBY
2ND FLR DUCT PRE-WRAP N SIDE
3RD FLR CEIL (CONF.)
HARD CEIL @ EMP. ENTY
MED PSI TEST
DRINK FOUNTAINS
HARD CEIL @ EMP. ENTY
EMP. ENTY LOBBY
CARGO ELEV. RM.
2ND FLR HARD CEIL IN CORR
CONF. 2ND FLR MECH.
2ND FLR
1ST FLR LOBBY SECT..
2ND FLR DUCT PRE-WRAP S. HALF
N/COMP. 1ST FLR
2ND FLR
2ND FLR INT. WALLS
2ND FLR MISC.
2ND FLR MISC. AREAS
2ND FLR HARD CEILS
2ND FLR MISC. AREAS
2ND FLR WALLS
2ND FLR RESTROOM
2 & 3 FLR PMTER FURRED WALLS
City of Carlsbad Bldg Inspection Request
For: 08/29/2007
Permit* CB063273
04/19/2007 14 Frame/Steel/Bolting/Welding AP TP
04/19/2007 34 Rough Electric AP TP
04/16/2007 14 Frame/Steel/Bolting/Welding WC TP
04/16/2007 16 Insulation PA TP
04/12/2007 17 Interior Lath/Drywall AP TP
04/10/2007 14 Frame/Steel/Bolting/Welding AP TP
04/10/2007 24 Rough/Topout WC TP
04/10/2007 34 Rough Electric AP TP
04/10/2007 44 Rough/Ducts/Dampers PA TP
04/09/2007 14 Frame/Steel/Bolting/Welding AP TP
04/09/2007 24 Rough/Topout AP TP
04/09/2007 34 Rough Electric AP TP
04/09/2007 44 Rough/Ducts/Dampers WC TP
04/05/2007 14 Frame/Steel/Bolting/Welding AP TP
04/05/2007 17 Interior Lath/Drywall WC TP
04/02/2007 14 Frame/Steel/Bolting/Welding PA TP
Inspector Assignment: TP
2ND FLR W. HALF, NO PLUMB. WALLS
E. STAIR ENCL CEIL
3RD FLR INT. WALLS
3RD FLR INT. WALLS
DUCT PRE WRAP S. SIDE 3RD FLR
3RD FLR E. HALF WALLS
RESTRMS, BRK RM. 3RD FLR
3RD FLR E. HALF WALLS
2 & 3 RD FLR MECH SHAFTS / SHAFT WALLS)
1 IN CORE SECT.
EsGil Corporation
_y """
* . In (Partnership with government for Quitting Safety
4
DATE: December 21, 2O06 a APPLICANT
a JURIS.
JURISDICTION: Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO.: 06-3273 SET: II
PROJECT ADDRESS: 1265 Laurel Tree Ln.
PROJECT NAME. 24 Hours Fitness CAC Facility - TI (office shell)
1X1 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
X] Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
REMARKS:
By: Sergio Azuela Enclosures:
Esgil Corporation
D GA D MB D EJ D PC 12/4 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 4 Fax (858) 560-1576
Carlsbad O6-3273
December 21, 20O6
VALUATION AND PLAN CHECK FEE Revised-12/20/06-S.A.
JURISDICTION: Carlsbad PLAN CHECK NO.: 06-3273
PREPARED BY: Sergio Azuela DATE: December 21, 2006
BUILDING ADDRESS: 1265 Laurel Tree Ln. 24 Mrs. Fitness CAC Fac./Office TI
BUILDING OCCUPANCY: B (TI only) TYPE OF CONSTRUCTION: I-FR
BUILDING
PORTION
Office TI
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
( Sq. Ft.)
49275
cb
Valuation
Multiplier
34.37
By Ordinance
Reg.
Mod.
VALUE ($)
1,693,582
$2,780,000
1 693 582
$6,662.61
Bldg. Permit Fee by Ordinance
Plan Check Fee by Ordinance
Type of Review:
Repetitive Fee
Repeats
Complete Review
D Other
i—i Hourly
D Structural Only
Hour*
Esgil Plan Review Fee
Comments:
$4,170.76]
$4,330.70
$2.911.84
$3,731.06
$2,508.66
Sheet 1 of 1
macvalue.doc
EsGil Corporation
In Partnership with government for <BuiCd~ing Safety
DATE: December 1, 2006 O^EPUCANT
JURISDICTION: Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO.: 06-3273 SET: I
PROJECT ADDRESS: 1265 Laurel Tree Ln.
PROJECT NAME: 24 Hours Fitness CAC Facility - TI (office shell)
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Interior Architects, Attn: Liliana Lenerman
3080 Bristol St., Costa Mesa, CA 92626
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Liliana Lenerman (v^) Telephoned (714) 754-1197
Date contacted: la. If foG? (by: [c- ) Fax #: (714) 754-1198
Mail u^Telephone .'Fax s In Person
REMARKS:
By: Sergio Azuela Enclosures:
Esgil Corporation
D GA D MB [X] EJ D PC 11/16 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 *• Fax (858) 560-1576
Carlsbad 06-3273
December 1, 2006
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 06-3273
OCCUPANCY: B
TYPE OF CONSTRUCTION: I-F.R.
ALLOWABLE FLOOR AREA: UL
basic allowable area for B/I-FR
SPRINKLERS?: YES
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: December 1, 2006
JURISDICTION: Carlsbad
USE: Office (TI only)
ACTUAL AREA: 49,275 SF (TI only)
STORIES: 3
HEIGHT:
OCCUPANT LOAD:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 11/16
PLAN REVIEWER: Sergio Azuela
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance of a building permit.
Code sections cited are based on the 2001 CBC, which adopts the 1997 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e.. plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw.dot
Carlsbad 06-3273
December 1, 2OO6
1. Please make all corrections, as requested in the correction list. Submit three new
complete sets of plans for commercial/industrial projects (two sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. UBC Section 107.2 requires the Building Official to determine the total value of
all construction work proposed under this permit. The value shall include all finish
work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator,
fire extinguishing systems and any other permanent equipment. Please provide
the designer's or contractor's construction cost estimate of all work proposed.
3. Indicate the use of all spaces adjacent to the area being remodeled or improved.
Please show it on plans for the areas on the East Side of line J at the second
and third floors.
4. Glazing in the following locations should be of safety glazing material in
accordance with Section 2406.4 (see exceptions):
a) Fixed or operable panels adjacent to a door where the nearest exposed
edge of the glazing is within a 24-inch arc of either vertical edge of the door
in a closed position and where the bottom exposed edge of the glazing is
less than 60 inches above the walking surface.
• Please clearly show it on the plans for all applicable windows. See
elevations on sheets A-7.5 to A-7.8. also there are some windows
shown on the Floor Plans adjacent to doors: 234, 246, etc.
b) , Individual fixed or operable panels, other than those locations described
above, that meet all of the following conditions:
i) Exposed area of an individual pane is greater than 9 square feet,
and:
ii) Exposed bottom edge is less than 18 inches above the floor, and:
iii) Exposed top edge is greater than 36 inches above the floor, and:
iv) One or more walking surfaces are within 36 inches horizontally of the
plane of the glazing.
• Please clearly show it on the plans for all applicable windows. See
elevations on sheets A-7.5 to A-7.8.
Carlsbad 06-3273
December 1, 2OO6
5. Note on the plans: "All interior finishes must comply with Chapter 8 of the UBC".
Specify "Class II flame spread rating (minimum) for 1hr corridor." And "Class III
flame spread rating (minimum) for ROOMS AND AREAS".
6. The tenant space and new and/or existing facilities serving the remodeled area
must be accessible to and functional for the physically disabled. See the
attached correction sheet. Title 24.
7. In areas where the occupant load is at least 50, two exits are required. See
Lunch Room. Table 10-A. Please note that the door 205 is located in the Kitchen
and the required exits shall not pass through kitchens, store rooms, or spaces
used for similar purposes. Section 1004.2.2.
8. Exit signs are required whenever two exits are required. Show all required exit
sign locations. Section 1003.2.8.2. Door 215 is providing exit to both sides,
therefore an exit sign shall be provided on each side of the door, adjacent to the
leaf of the door which is opening to provide exit.
9. If exit signs are required, provide the following notes on the plans, per Section
1003.2.8.2:
a) Exit signs shall be located as necessary to clearly indicate the direction of
egress travel.
b) Exit signs shall be readily visible from any direction of approach.
10. Show that exits are lighted with at least one foot candle at floor level. Section
1003.2.9.2.
11. Note on the plans: "All exits are to be openable from inside without the use of a
key or special knowledge." In lieu of the above, in a Group B, F, M or S
occupancies, you may note "Provide a sign on or near the exit door, reading
THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." This
signage is only allowed at the main exit. Section 1003.3.1.8.
12. Doors should not project more than 7 inches into the required corridor width
when fully opened, nor more than one-half of the required corridor width when in
any position. Section 1004.3. Please clearly show it on plans for doors 206 and
210B
13. All doors and gates, within the exit path from Group A occupancies to a public
way, shall not be provided with latches or locks unless they are equipped with
panic hardware. Section 1003.3.2.2.
a) Please show it on plans for the existing doors at stairway enclosure, and
at Entry Door on the First Floor on the North Side.
14. When two exits are required, dead end corridors are limited to 20 feet. Section
1004.2.6. Please show it on plans for the dead end adjacent to stairs and giving
access to Conference Room 202.
Carlsbad O6-3273
December 1, 2OO6
15. Corridors shall have interior door openings protected by tight-fitting smoke and
draft control assemblies rated 20 minutes. Doors shall be maintained
self-closing or be automatic closing by action of a smoke detector per Section
713.2. Doors shall be gasketed to provide a smoke and draft seal where the door
meets the stop on sides and top. Section 1004.3.4.3.2.1. Please show it on plans
for the doors at the existing Bathrooms.
16. If a room with an exhaust fan has a door opening into a rated corridor, show how
makeup air will be provided to the room. The door cannot be undercut, nor can a
louver in the door be provided. Section 1004.3.4.3.2.1. Please show it on plans
for the doors at the existing Bathrooms.
17. Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor-
ceilings and roof-ceilings shall be protected as required in UBC Sections 709 and
710."
18. Please see attached lists for electrical and energy corrections.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes a No a
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Sergio Azuela at
Esgil Corporation. Thank you.
* ELECTRICAL PLAN REVIEW
4 2002 NEC
* PLAN REVIEWER: Morteza Beheshti
19. All electrical sheets of the plans are required to be signed by the California
licensed engineer responsible for the plan preparation. Please include the
California license number, seal, date of license expiration and the date the plans
are signed. Business and Professions Code.
Carlsbad O6-3273
December 1, 2006
20. Please clarify panel and other equipment names for clarity. I.e., OP2 panels and
T-OP2 transformers.
21. The #6 equipment ground wire specified are undersized for the 400 ampere
overcurent device size(s).
22. Show or note on the plans the method used to limit fault currents on branch
circuits.
23. Please show location of panel "L3C" and "TSR" transformer.
24. Show on the plan the location of the existing service. NEC 110.26, 230.2.
25. Please specify the required: Room power disconnecting means; A separate
HVAC system; Listed equipment and fire resistant-walls floors and ceilings with
protected openings for the "information technology equipment room". NEC
645.2.
26. Provide multiple switch light controls at lobby lighting shown on E6.1. The
switches must be located within sight of the lights which they control. CBC Title
24, Sec 131 a-b
27. If utilizing a series-rated system, note on plans: "Overcurrent device enclosures
will be identified as series-rated and labeled in accordance with NEC 110-22"
and" The overcurrent devices shall be AIC rated per manufacturers, labeling of
the electrical equipment".
• ENERGY CONSERVATION
28. Please correct the number of 2'x4' luminaries to match the lighting plans.
29. Include all "Parts" of energy forms ENV-1-C and MECH-1-C onto the plans.
Note: If you have any questions regarding this Electrical or Energy plan review
list please contact Morteza Beheshti at (858) 560-1468. To speed the review
process, note on this list (or a copy) where the corrected items have been
addressed on the plans.
PLUMBING and MECHANICAL CORRECTIONS
PLAN REVIEWER: Eric Jensen
PLUMBING (2000 UNIFORM PLUMBING CODE)
• The plumbing is fine as submitted.
Carlsbad O6-3273
December 1, 2006
MECHANICAL (2000 UNIFORM MECHANICAL CODE)
• The mechanical is fine as submitted.
Note: If you have any questions regarding this Plumbing and Mechanical plan review
list please contact Eric Jensen at (858) 560-1468. To speed the review process,
note on this list (or a copy) where the corrected items have been addressed on
the plans.
DISABLED ACCESS REVIEW LIST
DEPARTMENT OF STATE ARCHITECT
TITLE 24
The following disabled access items are taken from the 2001 edition of California Building
Code, Title 24. Per Section 101.17.11, all publicly and privately funded public
accommodations and commercial facilities shall be accessible to persons with disabilities.
NOTE: All Figures and Tables referenced in this checklist are printed in the California
Building Code, Title 24.
• REMODELS. ADDITIONS AND REPAIRS
1. When alterations, structural repairs or modifications or additions are made to an
existing building, that building, or portion of the building affected, is required to
comply with all of the requirements for new buildings, per Section 1134B.2. These
requirements apply as follows:
a) The area of specific alteration, repair or addition must comply as "new"
construction.
MULTIPLE ACCOMMODATION SANITARY FACILITIES
2. Show or note, per Section 1115B.7.1.3 that the doors to the accessible water
closet compartment will be equipped with a self closing device with:
a) >34" clearance when located at the side of the compartment. Please revise
the dimension shown on detail 10/A6.1.
• DRINKING FOUNTAINS
3. Drinking fountains shall be accessible to individuals who use wheelchairs and to
those who have difficulty bending or stooping. This can be accommodated by the
use of "hi-low" fountains. Section 1117B.1.1.
Carlsbad 06-3273
December 1, 2006
4. Note on the plans that the drinking fountain(s) will comply with all applicable Title
24 provisions (bubbler height, etc.).
END OF DOCUMENT
Carlsbad 06-3273
.December 1, 2006
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: O6-3273
PREPARED BY: Sergio Azuela DATE: December 1, 2006
BUILDING ADDRESS: 1265 Laurel Tree Ln. 24 Hrs. Fitness CAC Fac./Office TI
BUILDING OCCUPANCY: B (TI only) TYPE OF CONSTRUCTION: I-FR
BUILDING
PORTION
Office TI
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
(Sq. Ft.)
49275
cb
RIHn Pprmit FPP hu Orrlinanrp *V
Valuation
Multiplier
. 34.37
By Ordinance
Reg.
Mod.
VALUE ($)
1,693,582
1,693,582
$4,479.75
Plan Check Fee by Ordinance
Type of Review:
Repetitive FeeRepeats
Complete Review
D Other
r-1 Hourly
D Structural Only
Hour*
Esgil Plan Review Fee
Comments:
$2,911.84
$2,508.66
Sheet 1 of 1
macvalue.doc
Carlsbad O6-3273
December 1, 2006
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 06-3273
OCCUPANCY: B
TYPE OF CONSTRUCTION: I-F.R.//
ALLOWABLE FLOOR AREA: UL
basic allowable area for B/I-FR
SPRINKLERS?: YES
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: December 1, 2006
JURISDICTION: Carlsbad
USE: Office (TI only)
ACTUAL AREA: 49,275 SF (TI only)
STORIES: 3
HEIGHT:
OCCUPANT LOAD:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 11/16
PLAN REVIEWER: Sergio Azuela
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance of a building permit.
Code sections cited are based on the 2001 CBC, which adopts the 1997 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list for a copy) where each
correction item has been addressed, i.e.. plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)Bforw.dot
Carlsbad 06-3273
December 1, 2006
1 . Please make all corrections, as requested in the correction list. Submit three new
complete sets of plans for commercial/industrial projects (two sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways: -
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858)560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. UBC Section 107.2 requires the Building Official to determine the total value of
all construction work proposed under this permit. The value shall include all finish
work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator,
fire extinguishing systems and any other permanent equipment. Please provide
the designer's or contractor's construction cost estimate of all work proposed.
3. Indicate the use of all spaces adjacent to the area being remodeled or improved.
Please show it on plans for the areas on the East Side of line J at the second
and third floors.
4. Glazing in the following locations should be of safety glazing material in
accordance with Section 2406.4 (see exceptions):
a) Fixed or operable panels adjacent to a door where the nearest exposed
edge of the glazing is within a 24-inch arc of either vertical edge of the door
in a closed position and where the bottom exposed edge of the glazing is
less than 60 inches above the walking surface.
• Please clearly show it on the plans for ail applicable windows. See
elevations on sheets A-7.5 to A-7.8. also there are some windows
shown on the Floor Plans adjacent to doors: 234, 246, etc.
b) Individual fixed or operable panels, other than those locations described
above, that meet all of the following conditions:
i) Exposed area of an individual pane is greater than 9 square feet,
and:
ii) Exposed bottom edge is less than 1 8 inches above the floor, and:
iii) Exposed top edge is greater than 36 inches above the floor, and:
iv) One or more walking surfaces are within 36 inches horizontally of the
plane of the glazing.
• Please clearly show it on the plans for all applicable windows. See
elevations on sheets A-7.5 to A-7.8.
A -7,5
Carlsbad O6-3273
December 1, 20O6
5. Note on the plans: "All interior finishes must comply with Chapter 8 of the UBC"
Specify "Class II flame spread rating (minimum) for 1hr corridor." And "Class III
flame spread rating (minimum) for ROOMS AND AREAS". &X&&C AN ~^
"
6. The tenant space and new and/or existing facilities serving the remodeled area
must be accessible to and functional for the physically disabled. See the
attached correction sheet. Title 24.
7. In areas where the occupant load is at least 50, two exits are required. See
Lunch Room. Table 10-A. Please note that the door 205 is located in the Kitchen
and the required exits shall not pass through kitchens, store rooms, or spaces
used for similar purposes. .Section 1004.2.2. f &{&&&. &H-7.2 \ A \~
•fettJM 205 fc HOf A KlTOfOl OtoOsefciN^ ffcdwt>6S) , Tffe
8. Exit signs are required whenever two exits are required. Show all required exit
sign locations. Section 1003.2.8.2. Door 215 is providing exit to both sides,
therefore an exit sign shall be provided on each side of the door, adjacent to the
leaf of the door which is opening to provide exit. AUrf&» Oil
9. If exit signs are required, provide the following notes on the plans, per Section
1003.2.8.2:
a) Exit signs shall be located as necessary to clearly indicate the direction of
egress travel.
b) Exit signs shall be readily visible from any direction of approach.
1 0. Show that exits are lighted with at least one foot candle at floor level. Section
1003.2.9.2.
1 1 . Note on the plans: "All exits are to be openable from inside without the use of a
key or special knowledge." In lieu of the above, in a Group B, F, M or S
occupancies, you may note "Provide a sign on or near the exit door, reading
THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." This
signage is only allowed at the main exit. Section 1003.3.1 .8. £Ht^T Al ~l )
12. Doors should not project more than 7 inches into the required corridor width
when fully opened, nor more than one-half of the required corridor width when in
any position. Section 1004.3. Please clearly show it on plans for doors 206 and210B
13. All doors and gates, within the exit path from Group A occupancies to a public
way, shall not be provided with latches or locks unless they are equipped with
panic hardware^ Section 1003.3.2.2.
a) Please show it on plans for the existing doors at stairway enclosure, and
at Entry Door on the First Floor on the North Side.AH *&&*> *$\o ) A\-Z W?&& , A(-5 tw&l
14. When two exits are required, dead end corridors are limited to 20 feet. Section
1004.2.6. Please show it on plans for the dead end adjacent to stairs and giving
access to Conference Room 202. "%&f\G>£l> C>U <=>ff£^f- AW~7.'2.
Carlsbad 06-3273
December 1, 2006
1 5. Corridors shall have interior door openings protected by tight-fitting smoke and
draft control assemblies rated 20 minutes. Doors shall be maintained
self-closing or be automatic closing by action of a smoke detector per Section
713.2. Doors shall be gasketed to provide a smoke and draft seal where the door
meets the stop on sides and top. Section 1004.3.4.3.2.1 . Please show it on plans
for the doors at the existing Bathrooms. ^K^^T* Al -2. , V&( Wtf& #*?
16. If a room with an exhaust fan has a door opening into a rated corridor, show how
makeup air will be provided to the room. The door cannot be undercut, nor can a
louver in the door be provided. Section 1004.3.4.3.2.1 .Please show it on plans
for the doors at the existing Bathrooms. && &A&&{ M&- 1
17. Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor-
ceilings and roof-ceilings shall be protected as required in UBC Sections 709 and710."
18. Please see attached lists for electrical and energy corrections.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes O No CJ
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Sergio Azuela at
Esgil Corporation. Thank you.
• . * ELECTRICAL PLAN REVIEW
* 2002NEC
• PLAN REVIEWER: Morteza Beheshti
19. All electrical sheets of the plans are required to be signed by the California
licensed engineer responsible for the plan preparation. Please include the
California license number, seal, date of license expiration and the date the plans
are signed. Business and Professions Code.
Carlsbad O6-3273
December 1, 2006 "^
20. Please clarify panel and other equipment names for clarity. I.e., OP2 panels and
T-OP2 transformers.
21. The #6 equipment ground wire specified are undersized for the 400 ampere
overcurent device size(s).
22. Show or note on the plans the method used to limit fault currents on branch
circuits. s
23. Please show location of panel "L3C" and "TSR" transformer.
24. Show on the plan the location of the existing service. NEC 110.26, 230.2.
25. Please specify the required: Room power disconnecting means; A separate
HVAC system; Listed equipment and fire resistant-walls floors and ceilings with
protected openings for the "information technology equipment room". NEC
645.2.
v. -
26. Provide multiple switch light controls at lobby lighting shown on E6.1. The
switches must be located within sight of the lights which they control. CBC Title
24,Sec131a-b
27. If utilizing a series-rated system, note on plans: "Overcurrent device enclosures
will be identified as series-rated and labeled in accordance with NEC 110-22"
and" The overcurrent devices shall be AIC rated per manufacturers, labeling of
the electrical equipment".
• ENERGY CONSERVATION
28. Please correct the number of 2'x4' luminaries to match the lighting plans.
29. Include all "Parts" of energy forms ENV-1-C and MECH-1-C onto the plans.
Note: If you have any questions regarding this Electrical or Energy plan review
list please contact Morteza Beheshti at (858) 560-1468. To speed the review
process, note on this list (or a copy) where the corrected items have been
addressed on the plans.
PLUMBING and MECHANICAL CORRECTIONS
PLAN REVIEWER: Eric Jensen
PLUMBING (2000 UNIFORM PLUMBING CODE)
( -_ ... -
• The plumbing is fine as submitted.
*
$8?
Carlsbad 06-3273
December 1, 2006
MECHANICAL (2000 UNIFORM MECHANICAL CODE)
• The mechanical is fine as submitted. O\L.
Note: If you have any questions regarding this Plumbing and Mechanical plan review
list please contact Eric Jensen at (858) 560-1468. To speed the review process,
note on this list (or a copy) where the corrected items have been addressed on
the plans.
DISABLED ACCESS REVIEW LIST
DEPARTMENT OF STATE ARCHITECT
TITLE 24
The following disabled access items are taken from the 2001 edition of California Building
Code, Title 24. Per Section 101.17.11, all publicly and privately funded public
accommodations and commercial facilities shall be accessible to persons with disabilities.
NOTE: All Figures and Tables referenced in this checklist are printed in the California
Building Code, Title 24.
• REMODELS. ADDITIONS AND REPAIRS
1. When alterations, structural repairs or modifications or additions are made to an
existing building, that building, or portion of the building affected, is required to
comply with all of the requirements for new buildings, per Section 1134B.2. These
requirements apply as follows:
a) The area of specific alteration, repair or addition must comply as "new"
construction. ok..
MULTIPLE ACCOMMODATION SANITARY FACILITIES
2. Show or note, per Section 1115B.7.1.3 that the doors to the accessible water
closet compartment will be equipped with a self closing device with:
a) >34" clearance when located at the side of the compartment. Please revise
the dimension shown on detail 10/A6.1. &&& te&ffe&k
\o ^ 14
• DRINKING FOUNTAINS
3. Drinking fountains shall be accessible to individuals who use wheelchairs and to
those who have difficulty bending or stooping. This can be accommodated by the
use of "hi-low" fountains. Section 11178.1.1. <66£ tiOflg Q <2»M.
Carlsbad O6-3273
December 1, 20O6
4. '
a,, app)icaWe
°*
END OF DOCUMENT
24 Hour Fitness
Plan File No. 05-3525
PLAN REVIEW SHEET FOR PLAN CHECK -
COMMENTS
1 . Show that exits are lifted with at least
one foot candle at floor level.
2. All electrical sheets to be signed by
engineer
3. Please clarity panel and other equipment
names for clarity, i.e., OP2. panels and T-
OP2 transformers
4. The #6 equipment ground wire specified
are undersized for the 400 ampere
overcurrent device size(s).
5. Show or note on plans the method used to
limit fault currents on branch circuits.
6. Please show location of panel 'L3C' and
TSR' transformer.
7. Show on the plan the location of the
existing service. NEC 110.26, 230.2.
8. Please specify the required: Room power
disconnecting means, a separate HVAC
system, Listed equipment and fire resistant-
walls, floors and ceilings with protected
openings for the "information technology
equipment room". NEC 645.2.
9. Provide multiple switch light controls at
lobby lighting shown on E6.1 The switches
must be located within sight of the lights .
which they control. CBC Title 24, Sec 131 a-
b.
10. If utilizing a series-rated system, note on
plans: "Overcurrent devices enclosures will
be identified as series-rated and labeled in
accordance with NEC 1 10-22" and 'The
overcurrent devices shall be AIC rated per
manufacturers labeling of the electrical
equipment."
1 1 . Please correct the number of 2'x4'
luminaries to match the lighting plans.
RESPONSES
EB fixtures shown on lighting plan to provide
90minutes of egress lighting. This will provide
1 foot candle average throughout the exiting
path. E2.1 and E2.2
All electrical sheets will be signed
All equipment is shown on plans.
E3.1 and E3.2
Revised on sheet E4.1
Shown on plans. Sheet E4.1
Added to plans. Sheet E3.2
Shown on plans. Sheet E4.1
EPO arid-Main shown for room. Sheet E3.2
Added to plans. Sheet E6.1
Note added. Sheet E4.1
Revised.
\ ' " .
City of Carlsbad
Public Works T- Eng inee ring
BUILDING PLANCHECK CHECKLIST
DATE:
BUILDING ADDRESS:
PROJECT DESCRIPTION:
ASSESSOR'S PARCEL NUMBER:
/ <& &> $
PLANCHECK NO.: CB (£?^ - 3^ ?3
^rt~*< ^
EST. VALUE:
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build.
D A Right-of-Way permit is .required prior to
construction of the following improvements:
DENIAL
Please
marked
or sp
codes
specif!
,nd
applicable
By:
By:
By:
iched report of deficiencies
:e necessary corrections to plans
for compliance with applicable
standards. Submit corrected plans and/or
r review. Only thetions
Date:
.Date:
Date:
*y. y/
FOR OFFICIAL USE ONLY
iNEERING AUTHORIZATION TO ISSUE BUILDING PERMIT:
'Vy-v^'-.G.';•-•-..:; ••,•-,:.;"•: ^-Da'te-v-:
ATTACHMENTS
D Dedication Application
D Dedication Checklist
D Improvement Application
D Improvement Checklist
D Neighborhood Improvement Agreement
D Grading Permit Application
D Grading Submittal Checklist
D Right-of-Way Permit Application
Q Right-of-Way Permit Submittal Checklist
and Information Sheet
ENGINEERING DEPT. CONTACT PERSON
Name: KATHLEEN M. FARMER
City of Carlsbad
Address: 1635 Faraday Avenue, Carlsbad. CA 92008
Phone: (760) 602-2741
NOTE: If there are retaining walls
associated with your project, please check
with the Building Department if these walls
need to be pulled by separate RETAINING
WALL PERMIT.
A-4
, CA 9200(8-7314 • (760) 602-2720 • FAX (760) 608*8S62
BUILDING PLANCHECK CHECKLIST
D D
SITE PLAN
1. Provide a fully dimensioned site plan drawn to scale. Show:
A. North Arrow
B. Existing & Proposed Structures
C. Existing Street Improvements
D. Property Lines (show all dimensions)
E. Easements
2. Show on site plan:
F. Right-of-Way Width & Adjacent Streets
G. Driveway widths
H. Existing or proposed sewer lateral
I. Existing or proposed water service
J. Existing or proposed irrigation service
A. Drainage Patterns
1. Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course.
2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building."
B. Existing & Proposed Slopes and Topography
C. Size, type, location, alignment of existing or proposed sewer and water service (s)
that serves the project. Each unit requires a separate service, however, second
dwelling units and apartment complexes are an exception.
D. Sewer and water laterals should not be located within proposed driveways, per
standards.
3. Include on title sheet:
A. Site address
B. Assessor's Parcel Number
C. Legal Description
For commercial/industrial buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
Show all existing use of SF and new proposed use of SF.
Example:
Tenant Improvement for 3500 SF of warehouse to 3500 SF of office.
F:\FarmertKathy\MASTERS\Building Plancheck Cklst Form (Generic).doc
BUILDING PLANCHECK CHECKLIST
ST1
D
,ND RD3'
D
DISCRETIONARY APPROVAL COMPLIANCE
4a. Project does not comply with the following Engineering Conditions of approval for
Project No._
D D D 4b. All conditions are in compliance. Date:
DEDICATION REQUIREMENTS
D D 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $ 17.000 . pursuant to Carlsbad
Municipal Code Section 18.40.030.
Dedication required as follows: •_
Dedication required. Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 %" x 11" plat map and
submit with a title report. All easement documents must be approved and signed
by owner(s) prior to issuance of Building Permit. Attached please find an
application form and submittal checklist for the dedication process. Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person. Applications will not be accept by mail or fax.
Dedication completed by:Date:
n n
IMPROVEMENT REQUIREMENTS
6a. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $ 82.000 . pursuant to Carlsbad Municipal Code Section
18.40.040.
Public improvements required as follows:
Attached please find an application form and submittal checklist for the public
improvement requirements. A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process. The completed application form and the requirements on the
F:\Fanmer\KATHYlMASTERS\Buildinfl Planctwck Cklst Forni (Generic).doc 3
BUILDING PLANCHECK CHECKLIST
1ST
D
ND2
D
RD3'
D
D D D
checklist must be submitted in person. Applications by mail or fax are not
accepted. Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit.
Improvement Plans signed by:Date:
6b. Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or
current grant deed on the property and processing fee of $ 400.00 so we may
prepare the necessary Neighborhood Improvement Agreement. This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit.
Future public improvements required as follows:
D D
D D D
6c. Enclosed please find your Neighborhood Improvement Agreement. Please return
agreement signed and notarized to the Engineering Department.
Neighborhood Improvement Agreement completed by:
Date:
6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective
improvements found adjacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy.
D D D
D D
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11.06.030 of the Municipal Code.
7a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities in cubic yards (cut, fill import,
export and remedial). This information must be included on the plans.
7b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be, submitted together with the completed application form
attached. NOTE: The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit.
Grading Inspector sign off by:Date:
D D 7c. Graded Pad Certification required. (Note: Pad certification may be required even
if a grading permit is not required.)
F:\Farmer\KATHY\MASTERS\BuiWina Planclwck Cklst Form (Genericj.doc Rev. 7/14/00
BUILDING PLANCHECK CHECKLIST
..ST
D D D 7d. No Grading Permit required.
D D D 7e. If grading is not required, write "No Grading" on plot plan.
MISCELLANEOUS PERMITS
D D D 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are
not limited to: street improvements, tree trimming, driveway construction, tying
into public storm drain, sewer and water utilities.
Right-of-Way permit required for: __ _
D D D 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153,
for assistance.
Industrial Waste permit accepted by:
Date:
NPDES PERMIT
D D D 10a. Storm Water Requirements Applicability Checklist Completed.
C3 L~H O 10b. Priority Determination and compliance:
D Priority Project
D Subject to Standard Permanent Storm Water BMP's
D Exempt
D D 11- Jd Required fees are attached
D No fees required
WATER METER REVIEW
D D D 12a. Domestic (potable) Use
Ensure that the meter proposed by the owner/developer is not oversized.
Oversized meters are inaccurate during low-flow conditions. If it is oversized, for
the life of the meter, the City will not accurately bill the owner for the water used.
• All single family dwelling units received "standard" 1" service with 5/8" service.
F:\Farmer\KATHYMWASTERS\Building Planctieck Cklst Form (Generic) doc f- Rev 7/14/00
BUILDING PLANCHECK CHECKLIST
|ST -.ND gRD
D D
• If owner/developer proposes a size other than the "standard", then
owner/developer must provide potable water demand calculations,
which include total fixture counts and maximum water demand in gallons
per minute (gpm). A typical fixture count and water demand worksheet is
attached. Once the gpm is provided, check against the "meter sizing
schedule" to verify the anticipated meter size for the unit.
• Maximum service and meter size is a 2" service with a 2" meter.
• If a developer is proposing a meter greater than 2", suggest the
installation of multiple 2" services as needed to provide the anticipated
. demand, (manifolds are considered on case by case basis to limit
multiple trenching into the street).
12b. Irrigation Use (where recycled water is not available) ^
All irrigation meters must be sized via irrigation calculations (in gpm) prior
to approval. The developer must provide these calculations. Please follow
these guidelines:
1. If the project is a newer development (newer than 1998), check the recent
. improvement plans and observe if the new irrigation service is reflected on
the improvement sheets. If so, at the water meter station, the demand in
gpm may be listed there. Irrigation services are listed with a circled "I",
and potable water is typically a circled "W". The irrigation service should
look like:
STA 1 +00 Install 2" service and
1.5: meter (estimated 100 gpm)
2.If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case
irrigation demand (largest zone with the farthest reach). Typically, Larry
Black has already reviewed this if landscape plans have been prepared,
but the applicant must provide the calculations to you for your use. Once
you have received a good example of irrigation calculations, keep a set for
your reference. In general the calculations will include:
• Hydraulic grade line
• Elevation at point of connection (POC)
• Pressure at POC in pounds per square inch (PSI)
• Worse case zone (largest, farthest away from valve
• Total Sprinkler heads listed (with gpm use per head)
• Include a 10% residual pressure at point of connection
3.. In, general, all major sloped areas of a subdivision/project are to be
irrigated via separate irrigation meters (unless the project is only SFD with
no HOA). As long as the project is located within the City recycled water
F:\FarmehKathy\MASTERS\Buildlng Plancheck Ckist Form (Generic).doc
BUILDING PLANCHECK CHECKLIST
1 £— O
service boundary, the City intends on switching these irrigation
' services/meters to a new recycled water line in the future.
CD D C 12c. Irrigation Use (where recycled water is available)
1. Recycled water meters are sized the same as the irrigation meter above.
2. If a project fronts a street with recycled water, then they should be
connecting to this line to irrigate slopes within the development. For
subdivisions, this should have been identified, and implemented on the
improvement plans. Installing recycled water meters is a benefit for the
applicant since they are exempt from paying the San Diego County Water
Capacity fees. However, if they front a street which the recycled water is
there, but is not live (sometimes they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego
Water Capacity Charge. If within three years, the recycled water line is
charged with recycled water by CMWD, then the applicant can apply for a
refund to the San Diego County Water Authority (SDCWA) for a refund.
However, let the applicant know that we cannot guarantee the refund, and
they must deal with the SDCWA for this.
[U D D 13. Additional Comments:
F:\Farmer\Kalhy\MASTERS\Buiiding Plancheck Cklst Form (Generic).doc
ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
D
D
Estimate based on unconfirmed information from applicant.
Calculation based on btfll3)ing plan/h)#ck plan submittal.
Address:Bldg. Permit No. <Qb -
Prepared by:Checked by:Date:
EDU CALCULATIONS: List types and square footages for all uses.
Types of Use: &J\ Sq. Ft./Units:
w
Types of Use: Sq. Ft./Units:
APT CALCULATIONS: List types and square footages for all uses.
Types of Use: rff). Sq. Ft./Units: ^^ Z-?Jw-p
Types of Use: _^Sq. Ft./Units:
EDU's:
EDU's:
ADT's:
ADT's:
II.
FEES REQUIRED:
WITHIN CFD: D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO
D 1. PARK-IN-LIEU FEE
FEE/UNIT:
PARK AREA & #:
X NO. UNITS:
U 2. TRAFFIC IMPACT FEE<-^s
)T'sA)NITS:
D 3. BRIDGE AND THOROUGHFARE FEE (DIST. #1
ADT's/UNITS: "7 3 / X /TEE//DT:
DIST. #3
D 4. FACILITIES MANAGEMENT FEE
UNIT/SQ.FT.:
D 5. SEWER FEE
EDU's: /"?'$ ^-
BENEFIT AREA: ___ _
EDU's:
ZONE: ->
X FEE/SQ.FT./UNIT:= $
FEE/EDU,
D 6. SEWER LATERAL ($2,500)
D 7. DRAINAGE FEES PLDA
ACRES:
= $_
= $
jtth
HIGH /LOW
FEE/AC:= $
D 8. POTABLE WATER FEES
UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION
1 of 2
(Ob
n/l
j
r?-
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER 1/17/06
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
«$10.000.00) f
OTHER
PLAZA CAMINO REAL
f •
^,
CARLSBAD COMPANY STORES
V1LLAGIFAJRE
COMPUn OFFICE BUILDING
DATB
OATB
Carlsbad Fire Department
Plan Review Requirements Category: TI, INDUST
Date of Report: 12-11-2006
Name:
Address:
Reviewed hy
Permit #: CB063273
Job Name: 24 HOUR FITNESS-49,275 SF TI
Job Address: 1265 LAUREL TREE LN CBAD
ttttiQMltUE3C£^_Xh£jLtem you have submitted for review is incomplete. At this ti
adequately conduct a review to determine cnmnr^ review
carefully all comment"rltj^ft^Ji^MiiiM|'llli11 I'l'I'IIV'i'i! lin in i i n plans and/or specifications, with change^cIoTRH
J*liiBWfflCeT8n?view and approval.
Conditions:
Cond: CON0001769
[MET] Concur with Esgil's exiting comments.
Entry: 12/11/2006 By: MS Action: AP
-4, X ~>
tf
pi" K
_l tf> LUUi fc Qo: - LU32 —J< L <-J CO LU 37U) W O I- <
5x m
(C
^
o
-£
xS
jC,
rr
3
0 0
04-26-2007
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plan Check Revision Permit No:PCR07062
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Reference #:
Project Title:
Applicant:
FRIAR GARY
714437-3467
1265 LAUREL TREE LN CBAD
PCR
2120402500 Lot#:
$0.00 Construction Type:
CB06-3273
24 HOUR FITNESS
REVISE CORE EXITING SYSTEM
0
NEW
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
ISSUED
03/22/2007
MDP
04/26/2007
04/26/2007
Owner:
ASCENT BILTMORE CARLSBAD L L C
111 W MON ROE ST #1111
PHOENIX AZ 85003
Plan Check Revision Fee
Additional Fees
$360.00
$0.00
Total Fees:$360.00 Total Payments To Date:$360.00 Balance Due:$0.00
Inspector:
FINAL APPROVAL
Date:Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ONLY
PLAN CHECK NO.
EST. VAL._J
Plan Ck. Deposit
Validated By_
Date
O 7-
__
Address (include Bldg/Suite #)Business Name (at this address)
Legal Description Lot No.Subdivision Name/Number Unit No.Phase No.Total # of units
Assessor's Parcel # •Existing Use Proposed Use
Description of Work SQ.FT.#of Stories # of Bedrooms # of Bathrooms
Address City ^la|f{2p _M TeleptonMf
ifQiGantraotar,' <?Q AgetitJorZContrsctorf ?GKOwn«r." Q Agent for1 Owner - ^'^7^'^T^^W^Si^i^
Name Fax #
Name Address City State/Zip Telephone #
Name City State/Zip Telephone #Address
l"
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code! or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031 .5 by any applicant for a permit subjects the applicant to a civil penalty Of not more than five hundred dollars ($500)).
Name Address
State License H . License Class
City State/Zip Telephone *
City Business License #
Designer Name Address
State License it
City State/Zip Telephone
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
["") I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are:
Insurance Company Policy No. Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100) OR LESS)
Q CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
SIGNATURE , DATE .
lllBBvfN'iR*BUILDER DECLARATION *:»''"'' V1 H "*''*' * V « "V * -I l<»%^^ « ^^Mi^"^?,***'*4**'*^ "i!^li|»^»'tM*5Hl/?*ik"fi*Sf''iff* *''i'l^,'J
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his Own employees, provided that such improvements are not intended or offered for sale. If, however, the building or Improvement is
sold within One year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to ah Owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law). ,
Q I am exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES [~1NO
2. I (have / have hot) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number): . - . ,__^ . . . . .
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work): . . „ , ; .
DATEPROPERTY OWNER SIGNATURE __ ____ _ _
PSllIIl&HissECTio^dB:^^ >'v '.'.(«, *!,*' " ,, rjfcid' ;n. j > .r-^MV^it,
Is the applicant or future building Occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES tD NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES CD N0
Is the facility to be constructed within 1 ,000 feet Of the outer boundary of a school site? O YES CD NO
IF ANY OF THE ANSWERS ARE YES. A FINAL CERTIFICATE 0*F OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(11 Civil Code).
LENDER'S NAME LENDER'S ADDRESS
', »«i( i * t r-* ' , „?»$£•, \ i7
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE T6 SAVE. INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: Ah OSHA permit is required for excavations over 5'6" deep and demolition or construction of structures Over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void il the building or work
authorized t>y such permit is not commenced vvjjJiinjWO days from the datejjUucbjjermit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is cofhrfiencedJoi^apenOd of 180 daysjgctflioiv!06.4.4U?H[orm Building Code).
APPLICANT'S SIGNATURE
YELLOW: Applicant PINK: Finance
DATE
f
EsGil Corporation
In (partnership with government for (RuiCding Safety
DATE: April 18, 2OO7 a APPLICANT
JURISDICTION: Carlsbad TTFLAN REVIEWER
Q FILE
PLAN CHECK NO.: 06-3273 (PCR07-62) SET: III REV
PROJECT ADDRESS: 1265 Laurel Tree Ln.
PROJECT NAME: 24 Hr FitnesS CAC Facility - Plan Changes
XI The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
XI Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: •_ Telephone $t
Date contacted: /)//v\(fcY:^ $&&'' 0^— |0/^a£%: 714-754-1198
Mail Telephone/ 'Fax In Person I
X3 REMARKS: (Ay City to verify that the intermediate landing between the second and third floors at the existing
stairs adjacent to Conference Room 202, comply with the minimum dimensions required by the
Code.
B. All sheets of plans shall be signed by the architect of record.
By: Sergio Azuela Enclosures:
Esgil Corporation • -,...,
Q^EJ ' D PC "";':'(J47l2
EsGil Corporation
In Partnership with government for (Building Safety
DATE: April 10, 2007 a APPLICANT
"
JURISDICTION: Carlsbad /OPLAN REVIEWER
a FILE
PLAN CHECK NO.: 06-3273 (PCR07-62) SET: II REV
PROJECT ADDRESS: 1265 Laurel Tree Ln.
PROJECT NAME: 24 Hr FitnesS CAC Facility - Plan Changes
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
Al The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Gary Friar
3080 Bristol St., Costa Mesa, CA 92626
I | Esgil Corporation staff did not advise the applicant that the plan check has been completed.
XJ Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Garv Friar Telephoned. (714)437-3467
Date contacted: wW (by: £/). Fax #: 714-754-1198
^ -sMail Telephone Fax-/ In Person
REMARKS:
By: Sergio Azuela Enclosures:
Esgil Corporation
D GA D MB D EJ D PC 04/03
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576
Carlsbad PCRO7-62
April 1O, 2007
RECHECK PLAN CORRECTION LIST
JURISDICTION: Carlsbad PLAN CHECK NO.: PCRO7-62
PROJECT ADDRESS: 1265 Laurel Tree Ln. SET: II (REV06-3273)
DATE PLAN RECEIVED BY DATE RECHECK COMPLETED:
ESGIL CORPORATION: 04/03 April 10, 2007
REVIEWED BY: Sergio Azuela ___^
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing
Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise
attenuation and disabled access. This plan review is based on regulations enforced by the Building Department.
You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering
Department or other departments.
The following items listed need clarification, modification or change. All items must be satisfied before the plans will
be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the
approval of the plans does not permit the violation of any state, county or city law.
A. Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for
commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected
sets can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department,
1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and
the Carlsbad Planning, Engineering and Fire Departments. .
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite
208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to
the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning,
Engineering and Fire Departments until review by EsGil Corporation is complete.
B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each
correction on this sheet has been made and return this sheet with the revised plans.
C. The following items have not been resolved from the previous plan reviews. The original correction number has
been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed
those pages containing the outstanding corrections. Please contact me if you have any questions regarding
these items.
D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this
list. If there are other changes, please briefly describe them and where they are located on the plans. Have
changes been made not resulting from this list?
QYes QNo
Carlsbad PCR07-62
April 10, 2007
1. Provide a complete list of all proposed plan changes, including the following:
a) A brief description of each one of the proposed plan changes.
i) The sheet of plans provided for this recheck included three areas
clouded. Please provide a brief description for each one of the
proposed plan changes included in these clouded areas.
b) The sheet or sheets of plans which are modified because each one of the
proposed plan changes.
i) It appear that the Door Schedule and also a new sheets A8,2 and A8.1
will be required for the new proposed changes and details.
c) The identification number used to identify each one of the proposed plan changes
on the plans.
i) Please clarify if the new proposed plan changes are identified on the
plans with a A number 5.
2. It appears that because one of the proposed plan changes the stairway landings on the
North Side of the stairway enclosure adjacent to Line J is being reduced. Please clearly
show on the plans full compliance of the stairway landings, which are impacted.
Additional corrections may follow.
a) The previously approved plans File # 063273 are showing the indicated
change on the stairway landings, as a result of one of the proposed plan
changes. Original correction is still applicable.
3. Some new details were included in the sheets A1-2 and A1-3, which were not included
within the new plans, nor were shown on the previously approved plans. See 17/A8-2,
13/A8-4 and 20//A8-1. Please provide all applicable new details. Additional corrections
may follow.
a) Please provide the new proposed details on the new sheets A8.2 and A8.1.
All sheets of the plans are required to be signed by the California licensed architect or
engineer responsible for the plan preparation. Please include the California license
number, seal, date of license expiration and the date the plans are signed. Business and
Professions Code.
If you have any questions regarding these plan review items, please contact Sergio
Azuela at Esgil Corporation. Thank you.
Carlsbad PCRO7-62
April 1O, 2OO7
JURISDICTION: Carlsbad
VALUATION AND PLAN CHECK FEE
PLAN CHECK NO.: PCR07-62
PREPARED'BY: Sergio Azuela DATE: April 1O, 2007
BUILDING ADDRESS: 1265 Laurel Tree Ln. 24 Hr Fitness CAC Facmty - Plan Changes
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: 1-FR
BUILDING
PORTION
Time
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
(Sq.Ft.)
cb
Blda. Permit FPP hu OrHinani-p 'W
Valuation
Multiplier
By Ordinance
Reg.
Mod.
VALUE ($)
Plan Check Fee by Ordinance $360.00
Type of Review:
D Repetitive FeeRepeats
D Complete Review
D Other
m Hourly
Structural Only
Hours
Esgil Plan Review Fee $288.00
* Based on hourly rate
Comments:
Sheet 1 of 1
macvalue.doc
(
v EsGil Corporation
In <Partnersfiip with (government for (Buififing Safety
DATE: March 3O, 2OO7 Q/APPLICANT
W^JURIS,
JURISDICTION: Carlsbad a PLAN REVIEWER
/ N a FILE
PLAN CHECK NO.: (£CR07-62j 3£- 337J SET: I (REVO6-3273)
PROJECT ADDRESS: 1265 Laurel Tree Ln.
PROJECT NAME: 24 Hrs Fitnes CAC Facility - Plan Changes
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
XI The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
XI The applicant's copy of the check list has
Gary Friar
3080 Bristol St., Costa Mesa, CA 92626
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
IXI Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: .Gar^riaruAAj Telephone #: (714) 437-3467
Date contacted: ^\w( (by:p ) Fax #:^<yMaik^""Telephone S Fax ^ In Person
REMARKS: ~
By: Sergio Azuela __ Enclosures:•r'S'iBSl^jEsgil Corporation 's<
D GA D MB D EJ D PC 3/26
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4- Fax (858) 560-1576
Carlsbad PCRO7-62
t March 3O, 2O07
GENERAL PLAN CORRECTION LIST
JURISDICTION: Carlsbad
PROJECT ADDRESS: 1265 Laurel Tree Ln.
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 3/26
REVIEWED BY: Sergio Azuela
PLAN CHECK NO.: PCRO7-62
DATE REVIEW COMPLETED:
March 30, 2007
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
• Please make all corrections and submit two new complete sets of prints to:
ESGIL CORPORATION.
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
Yes a No
Carlsbad PCRO7-62
i March 30, 2007
1. Provide a complete list of all proposed plan changes, including the following:
a) A brief description of each one of the proposed plan changes.
b) The sheet or sheets of plans which are modified because each one of the
proposed plan changes.
c) The identification number used to identify each one of the proposed plan changes
on the plans.
d) Please note that the required list of changes is essential for the plan checking of
the proposed plan changes.
2. It appears that because one of the proposed plan changes the stairway landings on the
North Side of the stairway enclosure adjacent to Line J is being reduced. Please clearly
show on the plans full compliance of the stairway landings, which are impacted.
Additional corrections may follow.
3. Some new details were included in the sheets A1-2 and A1-3, which were not included
within the new plans, nor were shown on the previously approved plans. See 17/A8-2,
13/A8-4 and 20//A8-1. Please provide all applicable new details. Additional corrections
may follow.
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the
plan review for your project If you have any questions regarding these plan review
items, please contact Sergio Azuela at Esgil Corporation. Thank you.
Carlsbad PCR07-62
March 3O, 20O7
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: PCR07-62
PREPARED BY: Sergio Azuela DATE: March 30, 2007
BUILDING ADDRESS: 1265 Laurel Tree Ln. 24 Hrs Fitnes/Plan Changes
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: I
BUILDING
PORTION
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
( Sq. Ft.)
Rlrin Pprmit FPP h\/ OrHinanrp ^T
Valuation
Multiplier
#N/A
Reg.
Mod.
VALUE ($)
7£r9
^r>('
^#N^
Plan Check Fee by Ordinance "v #N/A
Type of Review:
l~l Repetitive Fee
Repeats
Complete Review
D Other
(—, Hourly
fj Structural Only
Hour*
Esgil Plan Review Fee #N/A
Comments: ESGIL Fees to follow
Sheet 1 of 1
macvalue.doc
Carlsbad Fire Department
BUILDING
COPY
Plan Review Requirements Category: PCR,
Date of Report: 04-04-2007
Name:
Address:
Reviewed by:
Permit #: PCR07062
Job Name: 24 HOUR FITNESS
Job Address: 1265 LAUREL TREE LN CBAD
JfljCflMPMrlK The item you have submitted for review is incomplete. At this time, this office cannot
adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review
carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded",
to this office for review and approval.
Conditions:
Cond: CQN0001980
[MET],
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF
BUILDING PERMIT.
THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON,
CONDITIONS IN
CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS.
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW.
Entry: 04/04/2007 By: GR Action: AP