Loading...
HomeMy WebLinkAbout1275 HOOVER ST; ; CB141530; Permit• .. City of Carlsbad _44 ,1635iFaradayAv Carlsbad;CA92OO8 08-11-2014 Residential Permit Permit No: CB141530 Building Inspection Request Line (760) 602-2725 Job Address: 1275 HOOVER ST CBAD Permit Type: RESDNTL Sub Type: RAD Status: ISSUED 'Parcel No: 2061800100 Lot #: 0 Applied: 06/27/2014 Valuation: $28,981.00- Constuction Type: 5B Entered By: LSM Occupancy Group: Reference #: Plan Approved: 08/11/2014 # Dwelling Units: 1 Structure Type: Issued: 08/11/2014 Bedrooms: •. 0 Bathrooms: 0 Inspect Area: Orig PC #: Plan Check #: Project Title: MEISSNER RES- ADD 220 SF FOR 1 • SITTING ROOM Total Payments to Date: Applicant: ROBERT HOGARTH . 31375 STATION RD VALLEY CENTER CA 92082 760-703-6234 Building Permit AddI Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount StrongMotion Fee ..Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD#2 Fee BTD #3 Fee " Renewal Fee - Add'l Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size AddI Pot. WaterCon. Fee Red. Water Con. Fee Green Bldg Stands (SB1473) Fee .Green Bldg Stands Plan Chk Fee Total Fees: ' $560.55 Owner: MEISSNER LINDA M TRUST 03-09-99 1275 HOOVER ST CARLSBAD CA 92008 Meter Size AddI Red. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnLieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees Fire Sprinkler Fees TOTAL PERMIT FEES $560.55 Balance Due $302.15 $0.00 $211.50 $0.00 $0.00 $2.90 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $1.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $43.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $560.55 $0.00 FINAL APPROVAL Insector: Date: ///7_/ Clearance: NOTICE: Please take NOTICE that approval of your project includes the "imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. ,. .You are hereb FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity -: • • changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been cilven a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. ITHE APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: DPLANN(NG [--]ENGINEERING DBUILDING DFIRE EJHEALTH EHAZMATIAPCD Building Permit Application PlatCheck No. C I -- n In 4 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value C I T Y 0 F - CAR LSBIAD Ph: 760-602-2719 Fax: 760-602-8558 email: buiIdingcarlsbadca.gov Plan Ck. Deposit SD Date(,f7 I :Lj Iswppp 14 www.carlsbadca.gov JOB ADDRESS I SUITE#/SPACE#/UNIT# APN - CF/PROJEC1I' O_\r_. 01 R PHASE It II OF UNITS I B BEDROOMS Ill BATHROOMS I TENANT BUSINESS NAME I CONSTR. TYPE I 0CC GROUP DESCRIPTION OF WORK: include Square Feet of Affected Area(s) POP -p c4- I - L) y V1' ') EXIST USE PROPOSED USE I GARAGE (SF) PATIOS (SF) DECKS (SF) I FIREPLACE AIR CONDITIONING (FIRE SPRINKLERS -. YES # NOEl YES ENODI YES ENOD APPLICANT NAME PROPERTY OWNER 't Afz_. -5-5ri 44.. Primary Contact *Jc:y 1 2) - —' ivtiJ 1-O DDRESS AD DRESS ________________________ CITY -- V fr \ S'i Ci - STATE ZIP CA qa,067- CITY STATE ZIP elk 91 ó PIONE 7&o 101"7 1 1& FAX 1•S' ''V3" P'ONE )(.fiOOi- 1—e7 FAX EMAIL E- kl 0 & '2 4c 6 L' EMAIL C DESIGN PROFESSIONAL CONTRACTOR BUS. NAME" ADDRESS 4I, ADDRESS CITY STATE ZIP CITY <_STA ZI b PHONE L FAX PHONE (FAX EMAIL V AL STATE LIC. B STATE LIC.B 10 51D ICS I CITY BUS. LIC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant For such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law lohapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is esempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit Subjects the applicant to a civil Penalty of not more than five hundred dollars ($500)1. '' . .,'-' Workers Compensation Declaration: I hereby affirm under penally of perjury one of the following declarations: WI h ye and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 370001 the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers compensation, as required by Section 370001 the Labor Code, for the performangg of the work for ich this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. '5ti4rrt1.__S'Jf.J'c). Policy No. 0S7 - Expiration Date z.b/15 This section need not be completed if the permit is for one hundred dollars ($100) or less. []Certificate of Exemption: I certify that in performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secur ers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, ges as provided for In ectlon 3706 Lthe-Labor code, interest and attorney's fees. CONTRACTOR SIGNATURE AGENT DATE -T. , • (i]UDoø(!XU~LjYC1CI ' - (hereby affirm that lam exempf'from Contractor's License Law for the following reason: [] I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). - I am exempt under Section ______________Business and Professions Code for this reason: - 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. [Dyes ENo - 2. I (have! have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address! phone I contractors' license number): 4. I plan to pro,ride portions of the work, butt have hired the following person to coordinate, supervise and provide the major work (include name! address! phone! contractors' license number): - 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name! address! phone / type of work): ,.'PROPERTY OWNER SIGNATURE ' AGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? •Yes , No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? ., Yes No Is the facility to be constructed within 1,000 feel of the outer boundary of a school site? , Yes • No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ji I hereby affirm that there i a onstruction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name )/ ..I\ Lender's Address - I certify that have read the application and state thatthe above information is correct and that the information on the plans is accurate. I agree to complywith all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY INCONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: M OSHA permit is required for excavaton over 5' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Buildi Offdal under the proviizo s of this Code shall expire by limitation and became null and void lithe building or work authorized by such permit is not commenced within 180 days from the dale of such permit orZthe)ding orwork authorized such permit spended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). SAPPLICANT'S SIGNATURE - . DATE , j L.4 . •. . - STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. IICERTIFI CATE OF OCCUP A N CYt4tlCo mm erci allProjects .Z7lE'J Fax (760) 602-8560, Email bUiIdinQ(CarISbadCaqOV or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS - BUILDING ADDRESS - CITY - - - STATE - ZIP CITY STATE ZIP - . Carlsbad CA PHONE ,-'-. . -. - FAX - EMAIL -, .' OCCUPANTS BUS. LIC. No. - - - DELIVERY OPTIONS -t PICK UP: CONTACT (Listed above) OCCUPANT (Listed above) - CONTRACTOR (On P. 1) ASSOCIATED CB# ,MAILTO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On P. 1) NO CHANGE IN USE / NO CONSTRUCTION MAIL/ FAX TO OTHER: - CHANGE OF USE NO CONSTRUCTION ..APPLICANT'S SIGNATURE, - DATE . •; ..• : lnspection List Permit#: CB141530 Type: RESDNTL RAD MEISSNER RES- ADD 220 SF FOR SITTING ROOM Date Inspection Item InspectorAct Comments 11/13/2014 19 Final Structural - RI PM PLEASE 11/13/201489 Final Combo PB AP . • 10/31/2014 17 Interior Lath/Drywall PB AP 10/30/2014 84 Rough Combo PB AP 10/28/2014 13 Shear Panels/HD's PB AP ; 10/8/201415 Roof/Reroof PB AP 9/18/2014 11 Ftg/Foundation/Piers PB AP - - - 4' - * ?• • I -- - •! -. _q. •, - 4 - ;_•'- •••-- '--- • _4 • • '4 _ : • .*.•- 4 - 4 * - • 4 * •,;ç -* 4 .•_- 4 ', •- - -••--- • - 4 - - 4__* -• _ 4* - 4 * - 4. - - - • Friday November 14 2014 Page 1 of 1 - - ' EsGil Corporation In 'Partners/up with government for Building Safety DATE: 07/25/14 El APPLICANT D JURIS. JURISDICTION: Carlsbad 0 PLAN REVIEWER UFILE PLAN CHECK NO.: 14-1530 SET: II PROJECT ADDRESS: 1275 Hoover Street PROJECT NAME: Room Addition for Cramer (Meissner) Residence - .- The plans transmitted herewith have been corrected where necessary and substantially comply with-the jurisdiction's building codes. 4t 7 The plans transmitted herewith will substantially comply with the jurisdiction's building codes When minor deficiencies identified below are resolved and checked by building department staff. i The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck : The check list transmitted herewith is for your information. The plans are being held at Esgil •- Corporation until corrected plans are submitted for recheck LIII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The aplicant's copy of the check list has been sent to EsGil Corporation staff did not advise the applicant that the plan check has been completed LII EsGil Corporation staff dud advise the applicant that the plan check has been completed Person contacted Robert Telephone # (760) 703--6234 Date contacted (by ) Email rhogarth@aol.com Fax # (760) 751-9131 Mail Telephone Fax In Person REMARKS City to place soils stamp on the plans at issuance * •- 4•4 By Ray Fuller Enclosures EsGil Corporation El GA El EJ [1] MB 0 PC (P) 06/24/14 _ . . . -• - 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560 1468 • Fax(858)560 1576 :. ji • - EsGul Corporation In cPartners/izp with government for Building Safety DATE 07/08/14 DPPLICANT JURIS. JURISDICTION: Carlsbad E3 PLAN REVIEWER •' FILE 'PLAN CHECK NO::14-1530 ' SET:! ' PROJECT ADDRESS 1275 Hoover Street PROJECT NAME Room Addition for Cramer (Meissner) Residence LII The plans transmitted herewith have been corrected where necessary and substantially comply, with the jurisdiction's building codes ' The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information The plans are being held at Esgil 'Corporation until corrected plans are submitted for recheck. . The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant. contact person + The applicant's copy of the check list has been sent to: -Robert LII EsGil Corporation staff did not advise the applicant that the plan check has been completed EsGil Corporation staff did advise the applicant that the plan check has been completed "Persdn contacted:. Robert Telephone #: (760) 703--6234 • Date' contacted 1O (by\t3 Email rhogarth@aol.com Fax # (760) 751-9131 . 4 - .. MaiI. 'Telephone Fax in Person REMARKS City to place soils stamp on the plans at issuance By Ray Fuller Enclosures EsGil Corporation ..' GA El EJ LI MB LI Pc 06/30/14 4 .- .... - 44.• -- 4 I 9320 Chesapeake Drive Suite 208 • San Diego California 92123 • (858) 560-1468 • Fax (858) 560-1576 4, Carlsbad 14-1530 '07/08/14 PLAN REVIEW CORRECTION LIST - . . SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 14-1530 JURISDICTION: Carlsbad PROJECT ADDRESS: 1275 Hoover Street '• FLOOR AREA: I STORIES: 1 Addition 220 HEIGHT 8 ft per CBC REMARKS DATE PLXNS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: 06/27/14 ESGIL CORPORATION: 06/30/14 DATE INITIAL PLAN REVIEW PLAN REVIEWER Ray Fuller COMPLETED: 07/08/14 p FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, -' Uniform Mechanical Code, National Electrical Code and state laws regulating energy ' 'conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit .-- 4. . Present California law mandates that construction comply with the 2013 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC, . 2012 UPC,.2012 UMC and 2011 NEC. . . The above regulations apply, regardless of the code editions adopted by ordinance * * The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of. the 2012 International Building Code, the approval of the plans does not permit the violation of. any state, county or city law. .*Tb speed up the recheck process, please note on this list (or a copy) where each ,•• correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure'to enclose the marked up list when you submit the revised plans. I -• - 4 Carlsbad 14-1530 07/08/14 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for residential projects. For expeditious processing, - corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City , of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92009, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. ; NOTE: Plans that are submitted directly to EsGil Corporation only will not be • • reviewed by the City Planning, Engineering and Fire Departments until review by •. EsGil Corporation is complete 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). - .3. Please indicate on the plans whether the existing residence has a fire sprinkler - system installed. If so, then provide a note stating that any additions/alterations - will be provided with an automatic residential fire sprinkler system. Section R313.2. • 4 Plans to specify use of proposed room addition 5: Show or note that a battery-operated carbon monoxide alarms will be provided outside each separate sleeping area in the immediate vicinity of the bedrooms. . Section R315.2. .- 6. Show or note that a battery-operated smoke alarms will be provided in all • existing bedrooms and hallways leading to bedrooms. Section R314.3.1. Plans to reflect either existing or proposed exhaust fan at bathroom as L removing operable window. 8 The 4 x 12 spanning 10 ft appears may be overstressed Plans need to reflect • the type of existing roof system i.e. trusses or conventional and the existing , • • bearing points. For example if two point bearing trusses then with 30 # a ft live and dead load the 10 ft beam would be supporting 660#s aft. The alt to 4 x12-'- would be a 3 1,72 x 11 7/8 PLM or PSL with 4 x4 post for support - 9. The plans do not address required head clearance below proposed 4 x beam. Should be 7 ft clear. • . •' .• . - fr Carlsbad 14-1530 07/08/14 - 10. Plans to reflect a exterior WP GFCI at back of dwelling if none existing or was : removed due to addition. . . 11. Electrical plan does not reflect the required lighting at proposed exterior doors .. and switches. Any new lighting that includes outdoor lighting fixtures that are attached to a building are required to be high efficacy or controlled by a '- combination photo-control/motion sensor. 12.. Electrical plan to reflect how lighting in proposed addition complies with - residential energy lighting requirements any installed fixtures to be high efficacy or be controlled by a vacancy sensor or dimmer. 13. Include on the plans the following specifications for the new electrical devices being installed : - a) Tamper resistant receptacles required for all new locations. b) Arc fault protection for all new outlets (not just receptacles) located in .. T rooms described in NEC 210.12(B): Family, living, bedrooms, dining, halls, etc. ,14. Specify on the plans the following information for the roof materials, per Section Ri 06.1.1: Manufacturer's name and ICC approval number, or equal. Detail 4/3 is reflecting torch down and keynote 5/2 is reflecting tile? 15. Specify on the plans whether the existing house was built before or after 1994. .,. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons ,of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) * shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California 513407. .-Provide a sheet on the plans labeled "Green Building Code Requirements" and include - the following notes as applicable. Could not locate the following notes on the cover. sheet. . Recycling. Note on the plans that the contractor shall submit a Construction Waste Management Plan to the jurisdiction agency that regulates waste management, per CGC 4.408.2. - Opóration and maintenance manual. Note on the plans that the builder is to provide an operation manual (containing information for maintaining appliances, * . etc.) for the owner at the time of final inspection. CGC 4.410.1. . '. 18 Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC 4.504.1. . . • Carlsbad 14-1530 07/08/14 19. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and 4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood Products. CGC 4.504.2. - 20. ,Specify connection from existing.top plates to new i.e. some type of strap. 21 Are proposed footings are to be tied to existing footings? If so specify size, . length and spacing of dowels, length of embedment and if epoxied the type and' if special inspection is required. . 22 The plans do not comply with conventional framing as no braced wall panels '• . - .- shown on left side of proposed addition. Braced wall panels are required at each end of each braced wall line. Minimum panel length is 2'8" with hold downs (unless pre manufactured panels provided (i.e. Strong walls- Hardy Frames 1 - : could beprovided inside the narrow rake wall. ••. If applies: a) . Detail and reference any pre manufactured panel at rake wall condition: b) Provide Strong Wall or Hardy Frame details and reference to plans. - . Show any required deepen footings bolt type, size and embedment with 3" clearance below. Verify footings/ soil bearing adequate for tension and -. compression forces. • : 24. Where removing existing stucco shear please show on the plans how remaining walls will comply with conventional construction provisions ( R602- * Conventional Light-Frame Construction of the California Building Code) or provide an engineering analysis for the lateral load resistance of the wall(s) in question . The plans did not address existing common wall to proposed addition where it appears proposing to be the removing stucco shear. Plans to reflect how these wall (s) be laterally braced to roof sheathing as the additional 1/2 of the loads from proposed room addition and removal of stucco required that this• be replaced with brace wall panels extending to roof sheathing. Specify type,. - length of panels, nail size and spacing and shear transfer. To speed up the review process, note on this list (or a copy) where each correction. item has been addressed, i.e., plan sheet, note or detail number, etc. : Please indicate here if any changes have been made to the plans that are not a * result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. :• Have changes been made to the plans not resulting from this correction list? Please . indicate: Yes ( ) No ( ) -; • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake - Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, * :to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Ray Fuller at Esgil Corporation. Thank you. .! . • V Carlsbad 14-1530 :07/08/14 fDONOTPAY- THISISNOTANINVOICEJ VALUATION AND PLAN CHECK FEE 'JURISDICTION: Carlsbad. PLAN CHECK NO.: 14-1530 PREPARED BY: Ray Fuller DATE: 07/08/14 BUILDING ADDRESS 1275 Hoover Street " BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VB BUILDING PORTION . . AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Addition ' . 220 131.73 28,981 Air. Conditioning Fire Sprinklers TOTAL VALUE . 28,981 Jurisdiction Code . cb . By Ordinance - . I .151 Bldg. Permit Fee by Ordinance $302 V Plan Check Fee by Ordinance I $196 °I Type of Review Complete Review Structural Only Ei Other E Repetitive Fee . Repeats .. .. Hourly Hr. @ El * - EsGul Fee I $169 201 Comments: Add ½ hour for cal Green $43.00 Sheet of ,1 P... S - - macvalue.doc + .5' . y.*_ •-; . - - .5 . - , ~ K ~ ~ 0'0'~> - CITY OF CARLSBAD PLAN CHECK Community & Economic REVIEW Development Department 1635 Faraday Avenue TRANSMITTAL Carlsbad CA 92008 www.carlsbadca.gov —j DATE:07/07/14 PROJECT NAME: MEISSNER RESIDENCE PROJECT ID: CB14-1530 PLAN CHECK NO: 1 SET#: 1 ADDRESS: 1275 HOOVER APN: VALUATION: $28,981 ADDITION 220 SF This plan check review is complete and has been APPROVED by the ENGINEERING Division. By: KLAWRENCE A Final Inspection by the Division is required GYes MNo I This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. ONLY ITEMS MARKED 'X' NEED CORRECTION/CLARIFICATION Plan Check Comments have been sent to: You may also have corrections from one or rF,ore of thTê d,v,s,ohs Lid below. Approvalc from these di,sions may be required prior to the ,suãnceof abiw1ding prrnit Resubmitted plans should iffclude corrëätiOn fránfãll ditiioris. For questions or clarifications on the attached checklist please contact the following reyiewer as marked: PLANNING :- ENGINEERING FIRE PREVENTION 7606024610k 7606022750 ,. I 7606024665 • Chris Sexton [] Kathleen Lawrence Greg Ryan '— 760-602-4624 I- 760-602-2741 760-602-4663 Chris.Sexton@carlsbadca.gov Kathleen.Lawrence@carlsbadca.gov Gregory.Ryan@carlsbadca.gov Gina Ruiz [ Linda Ontiveros Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov D760-602-4664 Dominic Fieri Dominic.Fieri@carlsbadca.gov Remarks: a J-. Lot/Map No.: BLOCK C LOT 1 Subdivision/Tract: 2152 Reference No(s): Page 2 of 6 Set# . - Any outstanding issues will be marked with [J . Make the necessary corrections for compliance with applicable codes and standds. Submit corrected plans and/or specifications to the Building division for re-submittal to the Engineering division. - ' Items that conform to permit requirements are marked with7J LI 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show: North arrow Existing & proposed structures :i EZi Existing street improvements Poperty lines (show all dimensions) '. L11 EJ Easements .J Right-of-way width & adjacent streets E E:J Driveway widths ., . E EJ Existing or proposed sewer làteräl LJ E Existing or proposed water service Submit on signed approved plans: DWG No. on site plan: E2 Drainage patterns =Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. - =AD D THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building". =Existing & proposed s10pe5 and topography EJ Size, location, alignment of existing or proposed sewer and water service(s) that serves the project. Each unit requires a separate service; however, second dwelling units and apartment complexes are an exception. IM Sewer and water laterals should not be located within proposed driveways, per standards. Include on title sheet: E:J EZJ Site address E.1J LZJ Assessor's parcel number • - 7J Legal description/lot number - EJ For commercial/industrial buildings and tenant improvement projects, include: total building square footage .with the suare footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. LJ Show all existing use of SF and new proposed use. of SF. - .• Example: Tenant improvement for 3500 SF of warehouse to 3500 SF of office. * . _4_ - - 4.. 4', . 4 .4. 'F ••" - - - .4 _,..'4.••'_ .. 4'• .'- .-. 4-, 4 '. Set# - -2. DISCRETIONARY APPROVAL COMPLIANCE N!A L..J Project does not comply with the following engineering conditions of approval for project no ,. 3. DEDICATION REQUIREMENTS Dedication for all street rights-of-way adjacent to the building site and any storm drain or NjA . . utility easements on the building site is required for all new buildings and for remodels with a value at or, exceeding $_24,000 , 'pursuant to Carlsbad Municipal Code Section 18.40.030. • For single family residence, easement dedication will be completed by the City of Carlsbad, cost $115.00. - EEl [I1 Dedication required as foIIows 4. ;'• . --• •ç' -4 '.. 4 " .4. IMPROVEMENT REQUIREMENTS .. All needed public improvements upon and adjacent to the building site must be constructed . NJ1. at time of building construction whenever the value of the construction exceeds $124,000=, pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: 44 .. Curb, gutter, sidewalk, underground utilities. '.4 + •. 4', ' -- EEl EJ Construction of the public improvements must be 1éférred pursuant to Carlsbad Municipal Code Section 18.40. PIeeUbit'ä rent prperty titli reotô'rurrènt g'ThFit died onthi'ãerty"and procësirifëi of_$--Zsó w ray Neighborhood Improvement Areem'ènt Thiagreeméht must be 'sined notarized and Processing fee $157.00.. - -' '.-: Future public improvements required as follows: .-: ,- CURB; GUTTER, SIDEWALK • . * * UNDERGROUND UTILITIES - -- - - , . - . - ' • 1 •..' . •-Y---''-' _. • ' -- 4 - ''- ..- . • . . . .4 4 - • ' - - I - E-36 - - . 4 Page 3 of 6 REV 6/30/10 - -• 4, • - , • •-- -r ' . • - b * ,, •; ' Set# 1 : •. 5 GRADING PERMIT REQUIREMENTS * The conditions that require a grading permit are found in Section 15.16 of the Municipal - - Code. lnadequate information available on site plan to make a determination on grading requirements Include accurate grading quantities in cubic yards (cut fill import export and -. remedial) This information must be included on the plans If no grading is proposed write "NO GRADING" =Grading Permit required NOTE The grading permit must be issued and rough grading approval obtained. prior to issuance. of.a building permit. L11 1 Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required.) All required documentation must be provided to your Engineering Construction Inspector . The inspector will then provide the engineering counter with a release for the building permit. E1 No grading permit required El ii Minor Grading Permit required See attached marked up submittal checklist for project I specific requirements 6.' MISCELLANEOUS PERMITS E111 El RIGHT OF WAY PERMIT is required to do work in city right-of-way and/or private work adjacent to the public right of way. Types of work include but are not limited to street improvements, tree trimming, driveway construction, tyihg into public storm drain, sewer and -S water utilities. El El Right-of-way permit required for: Driveway - * -- . r 5-.- 5'• ,,, • -. , - .q •• . - . . - &••. --•. * .• S E36 Page of 6 REV 6/01/12 * 4. .. . S • ,. .,. . • . . '5 7. STORM WATER Costruction.Compliance QJ Project Threat AssessmentForm complete. - - . Enclosed Project Threat Assessment Form incomplete. Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached form -, -. -.- and return (SW 14-235 - EJ Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 . . SWPPP, payment of processing fee and review by city. - - - - -• Post-Development (SUSMP) Compliance - COMPLETE STORM EJ S Storm Water Standards Questionnaire complete. - -WATER ;QUESTIONNAIRE Storm Water Standards Questionnaire incomplete. Please make the Corrections, e-sin - the questionnaire and resubmit with next submittal. - • jJ Project is subject to Standard Storm Water Requirements. See city Standard Urban Storm Water Management Plan (SUSMP) for reference. - http:/Iwww. carlsbadca.gov/business/buildirig/Documents/EngStandsw-stds-voI4-ch2.df • JJ Project needs to incorporate low impact development strategies throughout in one or --. . • - more of the following ways: Rainwater harvesting (rain barrels or cistern) . . - Vegetated Roof . . S Bio-retentions cell/rain garden .................................... Pervious pavement/payers - El Flow-through planter/vegetated or rock drip lihé - - * • Vegetated swales or rock irfiltration swales Downspouts disconnect and discharge over landscape '. •. . Other: -- -4 •' .. 55• -- -- ..-H5 . - I.;. . -! - E-36 -. . Page 5 of 6 REV 6/01/12 / Set# 1 9 WATER METER REVIEW Domestic (potable) Use EJ LIJ What size miter is required? ' EIIJ jJ Where a residential unit is required to have an automatic fire extinguishing system, the minimum meter size shall be a 1" meter. NOTE: the connection fee, SDCWA system capacity charge and the - .. ' water treatment capacity charge will be based on the size of the meter necessary to meet the water use requirements. k EJ E.I For residential units the minimum size meter shall be 5/8",except where :.• the residential unit is larger than 3,500 square feet or on a lot lager than one quarter (1/4) acre where the meter size shall be % 8. FEES Required fees have been entered in building permit. E E1 Drainage fee applicable ' Added square feet - Added square footage in last two years? F yes no .- - ., - Permit No. Permit No. Project built after 1980 yes no - - Impervious surface flyes Eno . - Impact unconstructed facility byes Eno Y • - . - Fire sprinklers required yes flnô (is addition over 15' from center line) • - - Upgrade yes Eno- • EJ .: 21 No fees required - 10 Additional Comments S . .- ,. ,.•S•! - Attachments; J Engineering Application Storm Water Form Right-of-WayAppiication/info. Li Reference Documents - - . - - S - -* - E-36 • .• . - S Page 6 of 6 REV 6/01/12 STORM WATER POLLUTION PREVENTION NOTES ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPS WHEN RAIN IS EMINENT. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEERING OR BUILDING INSPECTOR DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH 3/4 INCH MINIMUM AGGREGATE. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. SPECIAL NOTES 4 PROJECT INFORMATION Site Address: tzlc 4N L Assessor's Parcel Number: jBC\ Project ID: Construction Permit No.0 14 1 Estimated Construction Start Date Project Duration '1 Months Emergency Contact: Jame: çu4a.isir 4 hour Phone: ii.o 7o 7PL/ILj Perceived Threat to Storm Water Quality 0 Medium ,7 Low If medium box is checked, must attach a site plan sheet showing proposed work area and location of proposed structural BMPs For City Use Only QlJ'(çFcAIERLSBAD STA DA R 1 SWPPP . Approved By: 1 ate Page lof3 I, I • '' ,. .4,. •, - 4,. - ', REV 4/30/10 '('4 CITY OF CARLSBAD STORM WATER COMPLIANCE FORM TIER I CONSTRUCTION SWPPP E-29 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov STORM WATER COMPLIANCE CERTIFICATE I My project is not in a category of permit types exempt from the Construction SWPPP requirements I My project is not located inside or within 200 feet of an environmentally sensitive area with a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s). I My project does not require a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code) I My project will not result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas that meets one or more of the additional following criteria: located within 200 feet of an environmentally sensitive area or the Pacific Ocean; and/or, disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical; and/or - disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse; and/or construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT ALL OF THE ABOVE CHECKED STATEMENTS ARE TRUE AND CORRECT. I AM SUBMITTING FOR CITY APPROVAL A TIER 1 CONSTRUCTION SWPPP PREPARED IN ACCORDANCE WITH THE REQUIREMENTS OF CITY STANDARDS. I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION. ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO MINIMIZE THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO MINIMIZE THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND, (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION . ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY THE CITY OF CARLSBAD. .. . / LH' ER'S AGNT N ME (P INT) -. ER'S AGENT NAME (SIGNATURE) DATE E9 - Erosion Control Control BMPs Tracking Control Non-Storm Water Waste Management and MaterialsSediment Control BMPs BMPs Management BMPs 'Pollution BMPs - c . _ E - Cn 'BestManagementPractice E. - • cc I (BMP)Description4 i cc a) j5 Ch 12 _0)E2O. CM M W °:0,a' L vC ca a 2CC cw Ne N)N . .u_. C) o 0O WO U) U) U) 0 a i C!) U)> U) (1)0.. (I). 0)o U) c Caic 0C 0.. >( CaCa C .2 U), -U)C U) .aCcot I 0 CASQA Designation 4 r7. CO C) '7 C IT L9 19 C? - ,7 Ci . .7. ? T 9. 19 (9 o UJ :o W o W 0 .U) w, w U), . w U) w U) - w U) Cl) ww U) . W ,0 - I— . U) Z U) Z C)) Z U) Z' - Construction Activity - W -. - Grading/SoilDisturbance --.•-- (Trenching/Excavation. Stockpiling - - — - -- - - — — — - - — Drilling/Boring - - - - - - - - - - — — - -P Concrete/AsphaltSaw — cuttinq - - - e Concrete flatwork — — — — - — — — - — — - — — - — — — — - --- - Paving - - - - — — — — — — - — — - — — - - - -- ConduitlPipelnstallation Stucco/Mortar Work )01 Waste Disposal - - — - — —J, _L Staging/Lay Down Area — -- — — - ' — - Equipment Maintenance - - - - - - - - and Fueling — - Hazardous Substance — -- ------ -- Use/Storage - - - - — — - Dewatering - — -- -- Site Access Across Dirt -- -- Other (list): ------- i.) jr. .. Instructions: Begin by reviewing the list of construction activities and checking the box to the left of any activity that will occur during the proposed construction. Add any other activity descriptions in the blank activity description boxes provided for that purpose and place a check in the box immediately to the left of the added activity description. For each activity descrribed, pick one or more best management practices (BMPs) from the list located along the top of the form. Then place an X in the box at the place where the activity row intersects with the BMP column. Do this for each activity that was checked off and for each of the selected BMPs selected from the list. For Example - If the project includes site access across dirt, then check the box to the left of "Site Access Across Dirt". Then review the list for something that applies such as "Stabilized Construction Ingress/Egress" under Tracking Control. Follow along the "Site Access Across Dirt" row until you get to the "Stabilized Construction Ingress/Egress" column and place an X in the box where the two meet. As another example say the project included a stockpile that you intend to cover with a plastic sheet. Since plastic sheeting is not on the list of BMPs, then write in "Cover with Plastic" in the blank column under the heading Erosion Control BMPs. Then place an X in the box where the "Stockpiling" row intersects the new "Cover with Plastic" column. To learn more about what each BMP description means, you may wish to review the BMP Reference Handout prepared to assist applicants in the selection of appropriate Best Management Practice measures. The reference also explains the California Stormwater Quality Association (CASQA) designation and how to apply the various selected BMPs to a project. E-29 Page 2 of 3 REV -J PLANNING DIVISION BUILDING PLAN CHECK Development Services Planning Division CiTY 0 F REVIEW CHECKLIST 1635 Faraday Avenue C A D I SD A r P 28 (760) 602-4610 IF\L L)I"L./ - www.carIsbadca.ov DATE: 7-23-14, PROJECT NAME: PROJECT ID: - PLAN CHECK NO: CB 14-1530 SET#: 2 ADDRESS: 1275 Hoover Street APN: 206-180-01-00 c6\A\Lk This plan check review is complete and has been APPROVED by the Planning \ Division.' By: Chris Sexton A Final Inspection by the Planning Division is required fl Yes Z No * You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. IIJ This plan check review is NOT COMPLETE. Items missing or incorrect are listed on .the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: rhogarth@aol.com -: For questions or clarifications on the attached checklist please contact the following reviewer as marked: I PLANNIN • G V 7606024610 - -- -- ENGINEERING 7GO , O750 V , FIRE PREVENTION 7606024665 Chris Sexton Kathleen Lawrence Greg Ryan 760-602-4624 - ' Chris.sexton@carlsbadca.gov • VV 760-602-2741 V pcathleen.Lawrence@carlsbadca.gov 760-602-4663 Grepory.Ryan@carIsbadca.gov Gina Ruiz - Linda Ontiveros Cindy Wong 760-602-4675 : - Gina.Ruiz@carlsbadca.gov - 760-602-2773 Linda.Ontiveros@carlsbadca.gov 760-602-4662 Cynthia.Wong@carlsbadca.gov V V V LI Dominic Fieri 760-602-4664 V Dominic.Fieri@carlsbadca.gov V Remarks: V - V -'V ,V•; ,. 4IV 4. Ile - ' • - - • Plan Check No CB 14-1530 Address 1275 Hoover St Date 7-23-14 Review# 2 Planner Chris Sexton Phone (760) 602-4624 V. APN 206-:1180-01-00 Type of Project & Use addition Net Project Density 1.0 DU/AQ Zoning R-1 -15 000 Gneral Plan 1M Facilities Management Zone 1 - CFD un/out) #_Date of participation Remaining net dev acres ' (For non-residential development Type of land use created by this permit ir REVIEW # •, 2 f 3 Legend Item Complete Item Incomplete -Needs your action El El Environmental Review Required YES El NO [1 TYPE DATE OF COMPLETION Compliance with conditions of approval If not state conditions which require action Conditióhs of'Approval: 'jj" DiscreticnaryAction Required: YES El NO ER TYPE V •V I' •-. .V V - 'APPROVAL/VRESO NO.' DATE V • PROJECT NO. ____ VV V OTHER RELATED.CASES: y. - ,. '• V V .,, 'Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval ' - El Coastal Zone Assessment/Compliance ' Project site located in Coastal Zone YES NO D CA Coastal Commission Authority' YES Q NO Q . , If, California Coastal, Commission Authority: Contact them at - 7575 Metropolitan Drive,- Suite 103 San Diego CA 92108-4402 (619) 767-2370 Determine status (Coatal Permit Required or Exempt) Exempt Habitat Management Plan . 'Data Entry Completed? YES El NO El If property has Habitat Type identified in Table 11 of HMP complete HMP Permit application and assess fees in Permits Plus V --(A/P/Ds,.Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken UPDATE') Aw El El lncItIsuonry Housing Fee required YES [I] NO El S (Effective date of Inclusionary Housing Ordinance - May 21 1993) V Data Entry Cdrnplèted?YESE NOEl (AIP/Ds Activity Maintenance enter CB# toolbar, Screens Housing Fees Construct V . V HbusingYIN,Ehté Fee, UPDATE!) . 4 9 VV. A - * V E_ V , s -. .. El LI Housing Tracking Form (forth P-20) completed YES LI NO El N/A El •• V - V VIV • V .4 V • V * •*V * V ' V V V V • - V V * '. ' - • - : • . * T •:-9V 'V V'V * • ' 'V V V -- •* .4 -I V •V ,, V -- - - P-28 • •V * V. * V Page 2 of 3 V - • • '• V 07/11 VV Site Plan LI' LI a fully dinensional site plan drawn to scale. Show: North arrow, property lines,'.. ,'Provide • 'easements, existing and proposed structures, streets, existing street improvements, right-of- way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) Provide legal description of property and assessor's parcel number. * * I City Council Policy 44 Neighborhood Architectural Design Guidelines LI"LI: i. Applicability: YES E] 'NO LI .LI Fa . 2. ProjectcomIlies: YES LI NOD .'- . - , Zoning S • 1. Setbacks: NONCONFORMING Front: Highland Dr Required 20' Shown , Interior Side: '- .. Required jQ Shown 1Q N Street Side:, Required iQ Shown 10'. i Rear: Hoover St Required Shown JQ Top of slope:, Required Shown LI LI ' '?.'..Accessory structure setbacks: N/A • Front:, ' Required Shown ____ • - • Interior Side'... , . Required Shown Street Side: Required Shown , • Rear: - , Required Shown * Structure separation: Required Shown -I S LI Z EL,. 3 Lot Coverage - Required <40% Shown 30.13% LI LI 4 Height Required Shown$Q '' ••, .5- . '* LI LI 5' Parking Spaces Required 2 Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown 1'I LI LI ' Additional Comments 1) Please provide the lot coverage on the plans. The lot coverage cannot Please dimension the how many feet from the front property line exceed 10% 2) on site plan (Highland Drive) to the existing single family residence. 3) Please show on the site plan that the - rear yard is the property along Hoover Street. The rear yard setback is 20 feet. '1) Setbacks are , nonóonforming. Per the Carlsbad Municipal Code, Section 21.48.050(C)(2)(b) Nonconforming Buildings and Uses - the area of expansion, when combined with prior expansions of the nonconforming structure, does not exceed forty percent of the floor space that existed prior to any. expansions or six hundred forty square feet, whichever is less. Please provide on the site plan, the existing sguaré footage and the square footage of any additions. If the square footage exceeds whichever is less, than a non-conforming construction will need to be applied for. I have .an attached an example of the information and how it should be on the plans. 7-22-14 (1) Please , 'contact the Building Division for a copy of previous building permits for any additions. There was • an addition in 2011 for a bedroom and an attached garage. This information will determined if a' Nonconforming Construction Permit (NCP) needs to be submitted. The NCP will be determined' by all previous additions. èf' ,ADPAtw tPD DATE AND ENTERED OK TO ISSUE APPROVAL INTO COMP# e3 "5 fT P-28 . , ' 07/11 • * S. - - • • -I-- 5.-S.,... , (• :- CB141530 1275 HOOVER ST 712,0 U( -T'D C.c-t-- 7/zI//L47D: P/fr ow- 7 (//L 4 Final Inspection required by.. D Plan J CM&l D Fire U SW 140 DISSUED j DCV. App ved ate By BUILDING iiw,,th 7 5 PLANNING c -,:a ,///9 ENGINEERING FIRE Expedite? Y N DIGITAL FILES Required? V N HazMat APCD Health Forms/Fees Sent Recd Due? By Encina V N Fire V N HazHealthAPCD V N PE&M (..Ja:7II'-/ V N School V N Sewer V N Stormwater V N Special Inspection V N CFD: V N LandUse: Density: ImpArea: FY: Annex: Factor: PFF: V () CommenTs Date Date Date Date Building rifr') L. Planning 7/-L //L 7/z 3//Li Engineering Fire Need? , 1one )çj jq 9Done tye,-( JJone cbone -! •'. .. City of Carlsbad 1635 FaradayAv Carlsbad, CA 92008 10-27-2014 Plan Check Revision Permit No:P0R14177 Building Inspection Request Line (760) 602-2725 Job Address: 1275 HOOVER ST CBAD Permit Type: PCR Parcel No: ' 2061800100 Lot #: 0 Valuation: ; $0.00 Construction Type: 5A Reférence#: CB14-1530 .. Pc #: J.Project Title:. MEISSNER RESIDENCE ADD WINDOW TO ADITION Applicant: RON HOGARTH 760 703-6234 Plan Check Revision Fee Fire Expedited Plan Review Additional Fees - .Total Fees; . $80.63 Total Payments To Date: $80.63 Balance Due: $80.63 $0.00 $0.00 Status: ISSUED Applied: 10/14/2014 Entered By: MDP Plan Approved: 10/27/2014 Issued: 10/27/2014 Inspect Area: Owner: MEISSNER LINDA M TRUST 03-09-99 1275 HOOVER ST CARLSBAD CA 92008 FINAL APPROVAL Inspector: Date: ______________ Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions. You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fppqipxp,c'tinns nf which vciu have nreviouslv been owen a NOTICE similar to this or as to which the statute of limitations has oreviously otherwise expired -city 0 Carlsbad PLAN CHECK REVISION Development Services APPLICATION 16 Building Division 35 Faraday Avenue B1 5 760-602-2719 www.carlsbadca.gov PianCheck Revision No. p Original Plan Check No. CY? L Project Address 11•i 4cya_. 'T Date 10114 /c Contact 4pGA61 Ph O7O&1V, L( Fax O\ _l 1 75 Email Cohtact Address _ -c CiJ ,Zip11 CA) General Scope of Work :1. Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person: 1. Elements revised: -. : 'I an s f Calculations Soils "rgy Other_________________________ Describe revisions in detail List page(s) where each revision is shown List revised sheets that replace existingsheets - boes this revision, in any way, alter the exterior of the project? Does this revision add ANY new floor area(s)? Lii Yes Does this revision)ct any fire related issues? Yes 8. Is this a compt? Ye No kSignature/_t( El No .1635 Faraday/venue, Carlsbad, CA 92008 : 760-602- 27 19 Fax: 760-602-8558 Email: building@carlsbadca.gov wwvv.carlsbadca.gov '- - .- EsGul Corporation In (Partnership with government for (Buz1Tdzng Safety DATE 10/23/14 .• APPLICANT URIS JURISDICTION: Carlsbad L3 PLAN REVIEWER FILE PLAN CHECK NO.: PCR14-177 (141530) SET: I PROJECT ADDRESS 1275 Hoover Street PROJECT NAME Plan Change for (Meissner) Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list '. and should be corrected and resubmitted for a complete recheck. . . The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person LII The applicant's copy of the check list has been sent to ............... . . 4 ., - . - • - EsGil Corporation staff did not advise the applicant that the plan check has been completed ET-Es'Gill Corporation staff did advise the applicant that the plan check has been completed Person contacted: Robert Telephone #: (760) 703--6234 Date contacted (by ) Email rhogarth@aol.com Fax # (760) 751-9131 Mail Telephone Fax In Person —REMARKS City to place soils stamp on the plans at issuance.- ssuance Renve SW1 and SW2 from previous approved sets and add to revised sets Previous approved City Sets sent back .•,. * B: Ray Fuller . Enclosures: EsGil Corporation . 'Y- E GA•.0 EJ.L1 MB E PC (P) 10/16/14 - .... • .,• . .. -, 1468 Fax(858)560-1576 9320 Chesapeake Drive Suite 208 • San Diego California 92123 • (858) 560 • 1 ,-. Carlsbad PCR14-177 (144530) 10/23/14 [DO NOT PAY- THIS IS NOT AN INVOICE] 4 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: PCR14-177 (14-1530) PREPARED BY Ray Fuller DATE: 10/23/14 - BUILDING ADDRESS: 1275 Hoover Street BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION VB -4 BUILDING PORTION - AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) - Air Conditioning Fire Sprinklers TOTAL VALUE - Jurisdiction Code cb - By Ordinance 1 Bldg Permit Fee by Ordinance I $80 631 Plan Check Fee by Ordinance Type of Review r 5. Complete Review r Structural Only 44 - r- 4 Other * I IJ Repeats . Hourly r— Repetitive Fee 0.75 Hr. @ * - - - .••,. EsGil Fee $86.00 I $64.501 -' Based o hourly rate S - - - Comments 4 S.' Sheet I of macvalue.doc + 4 -. • ... -. 4.'. 4 .5