HomeMy WebLinkAbout1287 CYNTHIA LN; ; CB901591; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
05-13-2009 Building Permit Permit No:CB901591
Building Inspection Request Line (760) 602-2725
Job Address 1287 CYNTHIA LN CHAD
Permit Type RAD Sub Type
Parcel No 1562301700 Lot # Status EXPIRED
Valuation $0 00 Const Type VN Applied 10/02/1990
OccGroup R3 Reference # Entered By DC
Appr/Issued
Project Title 544 SF ADD OFFICE/PLAY RM AND Inspect Area
EXTEND MASTER BEDROOM AND BR #2
Applicant Owner
GARCIA, ROBERT GARCIA ROBERT J&SHERYL A
1287 CYNTHIA LN
CARLSBAD, CA 92008
619 720-1525
Total Fees $198 00 Payments To Date $198 00 Balance Due
$0 00
Description Fee
Other 198 00
FINAL APPROVAL
Inspector Date Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
/ PERMIT APPLICATION
City of Car'lsbad Building Department
2075 Las Palmas Dr , Carlsbad, CA 92009 (em) «8-iiei
L PERMIT TYPE
~A DCOMMERCIALDNEWQfENANT IMPROVEMENT
B [] INDUSTRIAL QNEW QTENANT IMPROVEMENT
c ^RESIDENTIAL DAPARTMENT DCONDO ^SINGLE FAMILY DUELLING ^ADDITION/ALTERATION
DDUPLEX DDEMOLITION DISLOCATION DMOBILE H°ME QELECTRICAL DPLUMBING
DMECHANICAL npo°L DSPA DRETA""NG WALL DSOLAR DOTHER_
2 PROJECT INFORMATION PLAN CHECK No *#> /£"?/FOR OFFICE USE ONLY
Address_
earest Cross Streets
LEGAL DESCRIPTION f-tl Cnf'L^ALot No t\Subdivi
8533 107(53/90 0001 01 02
sion Name/Number Phase No <M H
Q. <V\cypIF SUBMITTED ^CHECK BELOU IF SUBMITTED
P? Energy Calcs Structural Calcs Soi Is Report Addressed Envelope
ASSESSOR'S PARCEL / £ if ~S 7 EXISTING USE PROPOSED USE
DESCRIPTION OF WORK
"VLoorW. iSXc^cXv^e"-^ oS-S-VcS^ ^Y\.^-^ ^Lec»<vv .rc\b.3\-t,(Z_"?3sAt-'^^-^-^wo ^.cKt^c^V"^^
CITY
SIGNATURE
4 APPLICANT
NAME
CITY
nCONTRACTOR ] AGENT FOR CONTRACTOR DOWNER
ADDRESS
STATE ZIP CODE
D AGENT FOR OWNER
DAY TELEP
PROPERTY OWNER
CITY STATE
ADDRESS IXST?
ZIP CODE
QLESSEE
DAY TELEPHONE *"|. ^£3" I
6 CONTRACTORNAME
CITY STATE
ADDRESS
ZIP CODE DAY TELEPHONE
STATE LIC *LICENSE CLASS CITY BUSINESS LIC #
SIGNATURE
DESIGNER NAME
CITY
7 WORKERS 'COMPENSATION
TITLE
ADDRESS
STATE ZIP CODE
DATE
DAY TELEPHONE STATE LIC #
Workers' Compensation Declaration I hereby affirm that 1 have a certificate of consent to self insure issued by the Director of Industrial Relations,
or a certificate of Workers' Compensation Insurance by an admitted insurer or an exact copy or duplicate thereof certified by the Director of the
insurer thereof filed with the Building Inspection Department (Section 3800, Lab C)
INSURANCE COMPANY POLICY NO EXPIRATION DATE
Certificate of Exemption 1 certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner
so as to become subject to the Workers' Compensation Laws of California
SIGNATURE
8 OWNER-BUILDER DECLARATION
Owner Builder Declaration hereby affirm that I am exempt from the Contractor's License Law for the following reason
[~] i as ownc;r of the property or my employees with wages as their sole compensation will ac the work and the structure is not intended or offered for sale
(Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who
does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however, the building
or improvement is sold within one year of complefon, the owner builder will have the burden of proving that he did not build or improve for the purpose
of sale )
[~\ i as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code
The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s)
licensed pursuant to the Contractor's License Law)
I am exempt under Section Business and Professions Code for this reason
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure
prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the
Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom
and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not
more than five hundred dollars [$500])
SIGNATURE DATE
COMPLETE THIS SECTION FOR NON RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act?
DYES DMO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7
DYES QNO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?
DYES QNO
IF AMY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS
OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
I CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code)
LENDER'S NAME LENDER'S ADDRESS
10 APPLICANT'S SIGNATURE
I certify that I have read tne application and state that the above information is correct I ngree to conply with all City oromances and State laws relating
to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes 1 ALSO
AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID
CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
Expiration Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building
or work authorized by such permit is not commenced within 180 days from the date of such permit or if the builamg o'- worn authorized by such permit is suspended
or abandoned at any time after tnc work is commenced for a period of ISO days (Section 303(d) Uniform Building Code)
] OUNER QCONTRACTOR PHONE APPROVED BY
DATE
WHITE File YELLOW Applicant PINK Finance
DATE: 09/30/91
TO: GARCIA, ROBERT
1287 CYNTHIA LANE
CARLSBAD, CA 92008
PLAN CHECK EXPIRATION
PC# CB901591 DATE: 10/02/91
ADDRESS: 1287 CYNTHIA LN
You have applied to have your plans checked on the date shown
above, and-you have not obtained your building permit.
The provisions of Section 304(d) of the Uniform Building Code
state:
"Section 304(d) Expiration of Plan Review
Applications for which no permit is issued
within one year following the date of
; '•. application shall expire by limitation, and
plans and other.data submitted for review
, f '' . - may ..thereafter be re turned-to the-applicant
"' V '*-"., or destroyed by "the Building Official.
: •'. ' •' :.'' ,. '..." . ," •' <
- In order to renew action.on;an.application
.''%•» f-> -fV ,-; after expiration, the "^applicant,1 shall resubmit
'. ; ;- :! ;;".:" plans and pay a new plan,'review fee." ,. ,
Please check the appropriate'box indicating your choice
and return"this letter to the BUILDING DEPARTMENT.
PROJECT ABANDONED.
PROJECT ABANDONED.
I,WILL PICK UP PLANS WITHIN 10 DAYS.
PLANS MAY BE DESTROYED.
If you have any questions, please contact the Building
Department at (619) 438-1161.
DORIS'COSMAN
Building Department
2O75 Las Palmas Drive Carlsbad, California 92OO9-1 576 <• (61 9) 438-1'< 6"
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 2O8
SAN DIEGO, CA 92123
(619) 56O-1468
DATE:
JURISDICTION:
PLAN CHECK NO:
PROJECT ADDRESS;
PROJECT NAME:
\-2--\\
<3 ^v c
3o - 1531 SET; 3C
(2-5
GPLAN CHECKER
JJFILE COPY
PPjDESIGNER
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
r?-m The plans transmitted herewith will substantially comply
Y/A with the jurisdiction's building codes when minor deficien-
cies identified _ <3tfLoixJ _ are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
D
D
The check list transmitted herewith is for your information
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
| The applicant's copy of the check list has been sent to:
^j Esgil staff did not advise the applicant contact person that
plan check has been completed.
I| Esgil staff did advise applicant that the plan check has
—' been completed. Person contacted:
Telephone #_Date contacted:
REMARKS: Q^ Q K S<=r^-noM S. <w-r 4 S t-<o-0 ro. o o 7 )
Enclosures
ESGIL CORPORATION
QGA DAA DRN QDM
ESGIL CORPORATION
9320 CHESAPEAKE DR , SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE:
JURISDICTION:
PLAN CHECK NO:
CARLSBAD
SET:
PROJECT ADDRESS; \ <2.
PROJECT NAME: £l\
jPLAN
_JFILE COPY
QUPS
I", DESIGNER
:ER
D The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the }urisdiction's-building codes when minor deficien-
cies identified are resolved and
D
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
Esgil staff did not advise the applicant contact person that
plan check has been completed^
j I Esgil staff did advise applicant that the plan check has
been completed. Person contacted:
Date contacted:
REMARKS:
Telephone
Enclosures >\_\t.rESGIL CORPORATION
DGA DAA DKN Q
PLAN CHECK NO:FOREWORD; PLEASE READ
JURISDICTION; CITY OF CARLSBAD
TO;
1-
ENCLOSURES; f\] 1)65
* ^£00 a
PROJECT ADDRESS:
FLOOR AREA:
STORIES:
RENARKS:
PLAN CORRECTION
CITY OF CARLSBAD
SINGLE FAKILY AND DUPLEX DWELLINGS
Date plans received by jurisdiction:
\Q\3\ °>0
Date plans received by Esgil Corporation:
Date initial plan check completed:
BV:
Applicant contact person:
$ Telethons;
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the
handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections based
on laws and ordinances by the Planning Department,
Engineering Department or other departments.
Present California law mandates that residential
construction comply with Title Ik and the following
model codes:
1988 UBC (eff. 1/1/90)
1988 UPC (eff. 1/1/90)
1987 NEC (eff. 10/28/87)
1988 UMC (eff. 1/1/90)
The above regulations apply to residential
construction, regardless of the code editions
adopted by ordinance.
The circled items listed need clarification,
modification or change, All items have to be
satisfied before the plans will be in conformance
with the cited codes and regulations. Per Sec.
303(c), 1988 Uniform Building Code, the approval of
the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, note on this lis
for a coov1 where each correction item has been
addressed i.e.. olan sheet, specification, etc.
when vou
NOTE: PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS HERE DELETED.
List No. 12, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1988 UBC)
Please make all corrections on the original
tracings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to:
Esgil Corporation, 9320 Chesapeake Drive,
Suite #208, San Diego, California 92123,
(619) 560-1468.
Please make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have been
returned to you by the jurisdiction, to-
The jurisdiction's building department.
Indicate on the Title Sheet of the plans, the
name of the legal owner and name_of person,
responsible for the preparation of^Sje plansT
"""
All sheets of plans must be signed by the
person responsible for their preparation.
(California Business and Professions Code).
Plans, specifications and calculations shall be
signed by the California state licensed
engineer or architect responsible for their
preparation, for plans deviating from
conventional wood frame construction. Specify
expiration date of license. (California
Business and Professions Code).
Specify on the Title Sheet of the plans the
gross floor area of each element of this
project including dwelling, garage, carport,
patio, deck and balcony. Section 302(d).
Provide a statement on the Title Sheet of the
plans that this project shall comply with Title
24 and 1988 UBC, UMC and UPC and 1987 NEC
Submit—fully
saalo showing
dimensioned
location, an
-plot—plan drawn to•
*-,—and—os«—of all-
exioting — an4 — proposed — structures on the loti
Identify property line.3 and ahow lot dimort&i-OBS-
and all eaeeaonfcc. — Show location of all cut or
fill slopes- — Show finish fleet- — elevations and
Show drainage patterns
Section 302(d).
with minimum slopes.
Indicate distance from property lines to
proposed building. Section 302(d).
lit.Show on the title sheet all structures, pools,
walls, etc. included under this application.
Any portion of the project shown on the site
plan that is not included with the building
permit application filed should be clearly
identified as "not included."
Clearly show if the lower level is a basement
or a story, based on the definitions in
Sections 403 and 420. Plot the finish grade
(as defined) on the elevations and dimension
the distance to the floor above, for story
determination.
On the cover sheet of the plans, specify any
items requiring special inspection, by way of
the following-
REQUIRED SPECIAL INSTRUCTIONS
In addition to the regular inspections, the
following checked items will also require
Special Inspection in accordance with Sec 306
of the Uniform Building Code.
ITEM REQ. IF
CHECKED
REMARKS
SOILS COMPLIANCE
PRIOR TO
FOUNDATION IhSP.
STRUCTURAL CONCRETE
OVER 2500 PSI
PRESTRESSED STEEL
FIELD WELDING
HIGH STRENGTH BOLTS
EXPANSION ANCHORS
SPECIAL MASONRY S
SPRAYED ON FIRE
PROOFING
PILES/CAISSONS
DESIGNER-SPECIFIED
OTHER
FTRE PROTECTION
Exterior walls closer than 3 feet to property
lines shall be one-hour rated construction and
have no openings. Table 5-A.
12/11/89
Exterior walls closer than 3 feet to a property
line shall have 30 inch parapets when the floor
area per floor exceeds 1,000 square feet.
Section 1709.
i-
i-
i-
Projections, including
more than 12 inches
from the property line.
eaves, may not extend
into the 3 foot setback
Section 1710.
Eaves over required windows shall be not less
than 30 inches from the side and rear property
lines. Section 504.
Plastic skylights shall not be installed within
that portion of a roof located within a
distance to property line where openings in
exterior walls are prohibited or required to be
protected. Section 5207 (a) 7.
Projections, including eaves, shall be one-
hour fire-resistive construction, heavy timber
or of noncombustible material if they project
into the 3' setback area from the property
line. Section 1710.
Show location of permanently wired smoke
detector:
a. Centrally located in corridor or area
giving access to sleeping rooms.
b. On each story.
c. In the basement.
d. When sleeping rooms are upstairs, at the
upper level in close proximity to the
stair.
e. In rooms adjacent to hallways serving
bedrooms, when such rooms have a ceiling
height 24 inches or more above the ceiling
height in the hallway.
NOTE: Detectors shall sound an alarm audible in
all sleeping areas of the unit. Section 1210
When the valuation of a room addition or repair
exceeds $1,000, or when sleeping rooms are
created, smoke detectors shall be provided at
existing bedrooms per item 19 above. Section
1210.
GENERAL RESIDENTIAL KfeXXJIKmgHIS
Habitable rooms, other than kitchens, shall
contain at least 70 square feet of floor area.
At least one room shall have not less than 120
square feet of floor area. Section 1207 (b).
Window area must be at least 1/10 of the floor
area and a. minimum of 10 square feet per
Section 1205 (a). Appears to be deficient in
i-
i-
i-
Openable window area in habitable rooms must
be 1/20 of the floor area and a minimum of 5
square feet. In bathrooms, laundry rooms and
similar rooms 1/20 of area is required and
minimum is 1.5 sq. ft. Section 1205 (a).
At least 1/2 of the common wall must be open
and have an opening not less than 25 sq. ft.
nor one tenth of the floor area of the
interior room if light and ventilation is
being supplied from an adjacent room. Section
1205 (a).
Required windows shall not open into a roofed
porch unless the ceiling height is at least 7
feet, the longer side is at least 65% open,
and the porch abuts a street, yard or court.
Section 1205 (a).
Provide mechanical ventilation capable of
providing five air changes per hour in
bathrooms, water closet compartments, laundry
rooms and similar rooms if required openable
windows are not provided. Section 1205 (c).
Show discharge point for exhaust air to be at
least 5 feet from any mechanical ventilating
intake. Section 1205(c).
Ductless fans cannot be used in bathrooms if a
tub or shower is present. Section 1205(c).
No habitable room, other than a kitchen, shall
be less than 7'0" in any dimension. Section
1207 (c).
Show that ceiling height for habitable rooms
is a minimum of 7"6", Section 1207 (a).
Show ceiling height for laundry rooms,
hallways, corridors, and bathrooms is a
minimum of 7'0". -Section 1207 (a).
Dimension on the plans the 30" clear width for
water closet compartments and 24" clearance in
front of water closet. Section 511 (a).
Specify safety glazing for glazing in
hazardous locations such as glass doors,
glazing adjacent to doors and glazing adjacent
to walking surfaces. Section 5406.
Glazing, in the same wall plane as a door,
must be safety glazing if within 12" of the
door and less than 60" above the walking
surface, unless the glazing is leaded or
faceted glass. Section 5406 (d) 6.
Glazing in shower and tub enclosures shall be
tempered, laminated or approved plastic
(including windows within 5 feet of tub or
shower floor). Section 5406 (d) 5.
8
2/12/90
36. Sleeping rooms shall have a window or exterior
door for emergency exit Sill height shall not
exceed 44" above the floor. The window must
have an openable area of at least 5.7 square
feet with the minimum openable width 20" and
the minimum openable height 2V. Section 1204.
37 Basements in dwelling units shall comly with
the above (even if not designated as sleeping
rooms). Section 1204.
38. Walls and floors separating units in a duplex
shall be of one-hour fire-resistive
construction. Section 1202(b).
45.
39.
40.
41.
A mezzanine is an intermediate floor and may
not have a floor area exceeding 33 1/3 percent
of the total floor area in the room below. The
mezzanine floor must have a clear height of 7
feet, above and below, and must have the long
side open to the room below except for posts
and protective vails or railings not exceeding
42" in height. Section 1716.
The loft you
mezzanine floor
Code definition,
show does not comply as a
and is, by Uniform Building
a story. Section 1716.
EXITS. STAIRWAYS. AND RAILINGS
Floors above the second story shall have not
less than 2 exits. Exceptions: 1. Occupied
roofs may have one exit if such occupied areas
are less than 500 square feet and located no
higher than immediately above the second story.
2. When the third floor vithin a unit does not
•exceed 500 sq. ft., only one exit need be
provided. Section 3303(a)
42.Required exit doorways shall be not less than
36" in width and not less than 6'8" in height,
and shall be capable of opening at least 90
degrees. Section 3304 (f).
43. Provide 36" high protective railing for
porches, balconies, and open sides of stair
landings. Openings between railings shall be
less than 6". Section 1711.
44. Show how guardrail connection details are
adequate to support 20 pounds per lineal foot
at a right angle to the top rail. Table 23-B.
Provide stairway and landing details.
3306 (b), (c) and (p).
Section
b.
c.
Maximum rise is 7" and minimum run is
11". When the stairs serves less than 10
occupants, or serves an unoccupied roof,
rise may be 8" maximum and run 9"
minimum.
Minimum headroom is 6'-8".
Minimum width is 36"
46.
47.
48.
49.
All handrails per Section 3306 (j), shall
satisfy the following:
a. Provide handrail for stairways with 4 or
more risers.
b. Handrail shall be 34" to 38" above the
nosing of treads.
c. The handgrip portion of handrail shall be
not less than 1 1/2", nor more than 2" in
cross-sectional dimension.
Every stairvay landing shall have a dimension,
measured in the direction of travel, at least
equal to the stairway vidth. Such dimension
need not exceed 36 inches. Section 3306 (g),
3304 (j).
An interior door may open inward at the top
step of a stairway provided the top step is
not more than 7 1/2" lover than the floor
level. Section 3304 (i).
Provide details of winding stairvay complying
with Section 3306 (d):
a.
b.
c.
Minimum tread is 6 inches at any point
and minimum 9 inches at a point 12 inches
from where the treads are narrowest.
Maximum rise is 8 inches.
Minimum width is 36 inches.
5/10/90
50/ Provide spiral stairway details, per Section
/ 3306 (f):lr
a. Minimum run is 7 1/2 inches measured at a
point 12 inches from vhere the treads are
the narrowest
b. Maximum rise is 9 1/2 inches. Maximum
clear opening between risers is 6 inches.
c. Minimum headroom is 6 feet 6 inches
d. The tread must provide a clear walking
area measuring at least 26 inches from the
outer edge of the supporting column to the
inner edge of the handrail.
Spiral stairvays may not be us_ed for required
exits when the area served is greater than 400
sq. ft. Section 3306 (f).
Provide I.C.B.O. Research Report and number for
metal stairway, or submit plans and
calculations and approved fabricator registered
with the building department or note that the
stairway fabrication plans shall be submitted
to and approved by the building official prior
to installation.
Exterior stairways shall not project into the 3
foot setback from the property lines. Section
3306 (n).
The walls and soffits of the enclosed usable
space under interior stairs shall be protected
on the enclosed side as required for one-hour
fire-resistive construction. Section 3306 (m).
7-
4-Within units, show that
minimum width of 36 inches.
ROOFIMG
corridors have a
Section 3305 (b).
Specify roof slope.
5/. Roof slope is not adequate for roof type
specified. Table 32-B,C,D and E.
5/8. Specify roof material and application. Chapteri •>•>32.
Specify I C.B 0. or U L. approval number for
roof materials not covered in UB.C.,e.g,
tile, etc. Section 107.
f
64.. Show roof drains and overflows. Section 3207.
Specify minimum 1/4 inch per foot roof slope
for drainage or design to support accumulated
water. Section 3207 (a) and Section 2305 (f).
6/. Provide skylight details ,to show compliance
with Sections 3401 and 5207 or provide
I.C B.O. approval number.
Plastic skylights must be separated from each
other by at least 4 feet. Section 5207 (a) 6.
Show attic ventilation. Minimum vent area is
1/150 of attic area or 1/300 of attic area if
at least 50% of the required vent is at least
3 feet above eave vents or cornice vents.
Show required area and area provided.
Section 3205 (c).
HASOHRY
Provide fireplace construction details or note
construction to be per attached fireplace _
standard drawing. Chapter 37
Show anchored veneer support and connections
attached to wood in Seismic Zones 3 and 4,
comply with Section 3006 (d)l and Section 2515
(a) . Show ties and 09 wire in horizontal
joints.
Show height and construction details of all
masonry walls. Chapter 24.
Show floor and roof connections to masonry
walls. Connection shall resist 200 pounds per
lineal foot or the actual design load,
whichever is greater. Cross grain tension or
bending in wood ledgers is not permitted.
Section 2310.
Show a minimum 2" air space and flashing
between planter and building walls.
Section 2516 (c) 7.
GARAGE AND CARPORTS
Garage requires one-hour fire protection on
the garage side of walls and ceiling common to
the dwelling. Table 5-B, Section 503 (d).
All elements supporting floor above garage,
including walls supporting floor joists, must
have one-hour f ire-resistive protection on the
garage side. Section 503 (b)
7-
/
Show 1
openings
503 (d).
3/8" solid core self-closing door for
between garage and dwelling. Section
Garages are not permitted to open into a room
used for sleeping purposes. Section 1104
12/11/89
75.
An occupancy separation is not required between
carport and residence, provided the carport is
open on two or more sides and has no enclosed
uses above. Section 503 (a) Exception 3.
Show garage framing sections, size of header
over garage opening, lateral cross bracing at
plate line, method bracing garage front and
holddowns if required. Chapter 23.
NOTE: Maximum shear panel height-to-width
ratio is 3 1/2 to 1 for plywood. Table 25-1.
Doors may open into the garage only if the
floor or landing in the garage is not more than
one inch lower than the door threshold.
Section 330^ (i).
Provide an 18" raised platform for any FAU,
water heater, or other device in the garage
which may generate a flame or spark. UMC
Section 508, UPC Section 1310 (a).
FOONDATION REQUIREMENTS
Per soils report, note on the plan the soils
classification, whether or not the soil is
expansive and note the allowable bearing value.
Section 2905 (c).
The foundation plan does not comply with the
soils report recommendations for this project.
Please review the report and modify design,
notes and details as required to show
compliance:
80/Provide notes on the foundation plan listing
the soils report recommendation for
foundations, slab and building pad preparation.
Provide a letter from the soils engineer
confirming that the foundation plan, grading
plan and specifications have been reviewed and
that it has been determined that the
recommendations in the soils report are
properly incorporated into the construction
documents (when required by the soil report).
The soils engineer recommended that he/she
review the foundation excavations. Note on
the foundation plan that "Prior to the
contractor requesting a Building Department
foundation inspection, the soils engineer
shall advise the building
that:
official in writing
1. The building pad was prepared in
accordance with the soils report,
2. The utility trenches have been properly
backfilled and compacted, and
3. The foundation excavations comply with
the intent of the soils report".
Show height of all foundation walls.
23.
Show height of
foundation walls.
retained earth
Chapter 23.
Chapter
on all
If cut or fill slopes exist, show distance of
foundation to edge of cut or fill slopes and
show steepness and heights of cuts and fills.
Chapter 29.
fe.Note on plans that
above finish grade.
wood shall be 6" minimum
Section 2907 (a).
'87J Note on plans that surface water will drain
away from building and show drainage pattern
and key elevations. Section 2905 (f).
88'. Dimension foundation per U.B.C. Table 29A:
Floors Footing
Supported* Stemwall Width Depth Thickness
1
2
3
6"
8"
10"
12"
15"
18"
12"
18"
2V
'"'Foundations may support a roof in
floors. Where only a roof is
foundation for one floor.
6"
7"
8"
addition to the
supported, use
.9. Show foundation sills to be pressure treated,
or equal. Section 2516 (c) 3.
Show foundation bolt size and spacing.
Section 2907 (f).
Specify size, I.C.B.O. number and manufacturer
of power driven pins. Show edge and end
distances and spacing. Section 302 (d).
2/13/90
If required, show size, imbedment and location
of hold down anchors on foundation plan.
Section 302 (d).
!>3. If hold downs are required, note on plan that
hold down anchors must be tied in place prior
to foundation inspection. Section 305 (e) 1.
Show adequate footings under all bearing walls
and shear walls. Section 2907 (b).
Show on the plans stepped footings for slopes
steeper than 1:10. Section 2907 (c).
Show minimum 18" clearance from grade to bottom
of floor joists and minimum 12" clearance to
bottom of girders. Section 2516 (c) 2.
Show pier size, spacing and depth into
undisturbed soil. Table 29-A.
Show minimum underfloor access
Section 2516 (c).
lOyO.
101.
of 18" x 2V.
w.
Show minimum underfloor ventilation equal to 1
sq. ft. for each 150 sq. ft. of underfloor
area. Openings shall be as close to corners as
practicable and shall provide cross ventilation
on at least two approximately opposite sides.
Section 2516 (c) 6.
FRAMING
Show wall bracing. Every exterior wood stud
wall and main cross-stud partition shall be
braced at each end at least every 25 feet of
length with 1x4 diagonal let-in braces or
equivalent. Section 2517 (g) 3, Table 25-V.
In 2-story buildings, shear panels at the first
story (at least 48 inches in width) shall be
located at each end or as near thereto as
possible and comprise at least 25 percent of
the linear length of the wall, or provide
design. Section 2517(g)3, Table 25-V.
Note cross bridging or blocking. Floor joists
and rafters 12" or more in depth shall be
supported laterally by bridging at intervals
not exceeding 8 feet, unless both edges are
held inline. Sec. 2506 (h)/2517 (d) 6.
Show blocking at ends and at supports of floor
joists, rafters and trusses at exterior walls.
Section 2517 (d) 3, 2517 (h) 6.
Bearing partitions, perpendicular to joists,
shall not be offset from supporting girders,
beams, walls or partitions, more than the depth
of the joist. Section 2517 (d) 5.
Show rafter ties. Rafter ties shall be spaced
not more than 4 feet on center and be just
above the ceiling joists, where rafters and
ceiling joists are not parallel. Section 2517
(h) 4.
. Show rafter purlin braces to be not less than
45 degrees to the horizontal.
Section 2517 (h) 5.
Show double top plate with minimum 48" lap
splice. Section 2517 (g) 2.
Show nailing will be in compliance with Table
25-Q.
109. Show or note fire stops at the following
locations per Section 2516 (f):
a. In concealed spaces of stud walls and
partitions, including furred spaces, at
the ceiling and floor levels and at 10
foot intervals along the length of the
wall;
b. At all interconnections between concealed
vertical and horizontal spaces such as
occur at soffits, drop ceilings and cove
ceilings;
c. In concealed spaces between stair
stringers at the top and bottom of the
run and between studs along and inline
with the run of stairs if the walls under
the stairs are unfinished; and
d. In openings around vents, pipes, ducts,
chimneys, fireplaces and similar openings
which afford a passage for fire at
ceiling and floor levels, with
noncombustible materials.
110T. In duplexes, draft stops shall be provided in
floor-ceiling assemblies and attics in line
with walls separating units and separating
units from common areas.
Show stud size and spacing. Maximum allowable
/ stud heights: Bearing wall: 2 x4 and 2x6
max. 10"; Non-bearing: 2x4 max. 14', 2x6
/max. 20'. Table 25-R-3.
Studs supporting two
ceiling must be 3 x 4
Table 25-R-3.
floors, a roof
or 2 x 6 at 16"
and
o.c.
Note on A I.T.C. Certificate of Compliance for
glued laminated wood members shall be given to
the building inspector prior to installation.
Section 2505.
o.c,rvr T^^
O\- \T'7.'- I Ifou Coouo
\T >~2/12/90
TO M'Bf?- frflo^s/J '
lie.
1-
VLt.
Detail all post-to-beam and post-to-footing
connections and reference the detail to the
plan. Section 2516 (m).
Detail shear transfer connections, including
roof and floor diaphragms, to shear walls.
Section 2513.
Specify nail size and spacing for all shear
walls, floor and roof diaphragms. Indicate
required blocking. Maintain maximum diaphragm
dimension ratios. [Tables 25 I, J, K and
Section 4714 (d)].
Provide truss details and truss calculations
for this project. Specify truss identification
numbers on the plans.
Show 1/2" minimum clearance between top plate
of interior partitions and bottom chord of
trusses. (To ensure loading will be as
designed).
, Provide roof framing plan and floor framing
plan. Section 302 (d).
Provide framing sections through
ii
Section 302 (d).
.. Specify all header sizes for opening over 4'
wide. Section 2517 (g) 5.
1Z2. Provide calculations for main vertical and
horizontal framing members and post footings.
Section 302 (b).
12/3. Provide calculations for lateral loads, shear
' panels, shear transfer and related. Sof+inn
302 (b).
Section
In Seismic Zones 3 and 4, the allowable shear
wall values for drywall in Table 47-1 must be
reduced 50 percent when considering earthquake
loads. This does not apply to wind loads.
Footnote 1. -
Show on the plans all structural requirements
developed in the structural calculations.
Section 302 (d). (See comments below or at
end.)
126.Columns and posts located on concrete or
masonry floors or decks exposed to the weather
or to water splash or in basements and which
support permanent structures shall be
supported by concrete piers or metal pedestals
projecting above floors unless approved wood
of natural resistance to decay or treated wood
is used. Section 2516 (c) 4.
Individual concrete or masonry piers shall
project at least 8 inches above exposed ground
unless the columns or posts which they support
are of approved wood of natural resistance to
decay or treated wood is used.
Section 2516 (c) 4.
1#8. Show location of attic access with minimum
size 22" x 30". Section 3205.
2&
f
y.
. Show draft separation for attic areas between
units in a duplex. Section 2516 (f).
Specify plywood and/or particle board
thickness, grade and panel identification
index. Table 25-S.
When roof pitch is less than 3:12, design
ridge as a beam. Section 2517 (h).
If foundation cripple wall studs are less than
14" high, framing shall be solid blocking, or
sheathed with plywood. Section 2517 (g) 4.
Cripple wall studs exceeding 4 feet in height
shall be 3 inch by 4 inch or 2 inches by 6
inches when supporting 2 stories.
Section 2517 (g) 4.
Show plywood sheathing over exposed eaves, or
other weather exposed areas, is "bonded with
exterior glue.".' Plywood used for exterior
wall covering shall be the exterior type.
Section 2516 (i), 2516(g)3.
. Detail truss layout for 30" x 30" attic
access, if required for equipment in the
attic.
6. Ridges, hips, and valleys shall be at least
one size larger than supported rafters.
Section 2517 (h) 3.
In open beam construction, provide strap ties
across the beams at the ridge support.
Section 2501 (b).
MECHANICAL (UNIFORM MECHANICAL CODE)
All heating, ventilating, and cooling systems and
appliances shall comply with the Uniform Mechanical
Code.
2/12/90
'39'. Show the size, location and type of all heating
and cooling appliances or systems.
ELECTRICAL (HATIOHAL ELECTRICAL CODE)
TO. Show source of combustion air to furnace, per
' ' Chapter 6, UMC.4
4
i-
1/6.
4.
1^0
Every dwelling unit shall be provided with
heating facilities capable of maintaining a
room temperature of 70 degrees F. at 3 feet
above the floor in all habitable rooms. Show
basis for compliance. UBC, Sec. 1212.
Show minimum 30" deep unobstructed working
space in front of furnace. Section 505, UMC.
Furnace shall not be installed in any bedroom,
bathroom or in a closet or confined space with
access only through such room unless
specified as direct vent appliance, enclosed
furnace or electric heating appliance.
Section 70^ UMC.
Show I.C.B.O. approval number for prefab
fireplace. Show height of chimney above roof
per I.C.B.O. approval or Table 37-B.
Show access to the attic containing equipment
to be minimum 30 inches by 30 inches. The
opening may be 22 inches by 30 inches if the
equipment can be removed through such opening.
Section 708 UMC.
Where equipment is installed in the attic, the
distance from the attic access to such
equipment shall not exceed 20 feet.
Note that passageway to the attic furnace shall
be unobstructed and have continuous solid
flooring not less than 2U inches wide.
Section 708 UMC.
Show permanent electrical outlet and lighting
fixture controlled by a switch for the attic
furnace. Section 708 INC.
Show details to comply with Section 709 for
furnace under the floor, or Section 710 for
roof or outside furnace.
Note on plan: Gas vents and non-combustible
piping, in walls, passing through three floors
or less shall be effectively draft stopped at
each floor or ceiling.
UBC, Section 1706 (a) 6.
All wiring shall
Electrical Code.
comply with the National
Show on the plan the amperage of the
electrical service, the location of the
service panel and the location of any sub-
panels. If service is o\er 200 amps, submit
single line diagram, panel schedule and load
calculations.
'. Show location of all electrical receptacles.
I Electrical receptacle locations and/or spacing
is not adequate in KtgtO iQVH-L-^i \*J
167.
1/8.
"/
16jf.
Provide
1903.dryer vent to outside. UMC, Section
16i.
Show at least one convenience outlet other
than outlets for laundry, etc., outdoors, in
garages and basements. NEC, Art. 210-52.
Note convenience outlets in bathrooms, kitchen
counter top(s) within 6 feet of the kitchen
sink, outdoors, and in garages and basements
(other than for laundry and similar equipment)
shall be GFI protected. NEC, Art. 210-8.
Note electrical system ground to be provided
per NEC, Art. 250-81.
PUMBING (OHIPOBM FLGMBIHS COPE)
Show water heater size, type and location on
plans. UPC, Section 1301.
Show source for providing combustion air to
fuel burning vater heater. If wall openings
in an enclosure are used, at least one-half of
the required opening area shall extend into
the upper twelve inches of the enclosure and
one-half within the lower twelve inches. UPC,
Section 1307.
Fuel combustion vater heater shall not be
installed in bath or bedroom or in a closet
opening into bath or bedroom. UPC, Section
1309.
Provide adequate barrier to protect water
heater from vehicle damage. An 18" platform
for the water heater does not satisfy this
requirement. UPC, Section 1310.
Show I and P valve on water heater
route of discharge line to exterior.
UPC, Section 1007 (e).
and show
1/19/90
163.
1/4.
y?2
Show that water heater is adequately braced to
resist seismic forces, when not connected by
rigid pipe. UMC Section 504(d).
Show shower stall can accommodate a 30" circle
and has a minimum floor area of 1,024 sq. in.
UPC 909 (d).
Provide clothes washer hook-up for each unit.
Title 24, Part 3.
NOISE INSULATION (DUPLEXES)
Show details of duplex common (party) walls and
floor/ceiling assemblies to achieve a Sound
Transmission Class (STC) rating in walls of 50
decibels and an Impact Insulation Class (IIC)
rating on floor/ceiling of 50 decibels.
Title 24.
Show how penetrations of assemblies for piping,
electrical devices, recessed cabinets,
bathtubs, soffits, or heating ventilating, or
exhaust ducts shall be sealed, lined, or
insulated to maintain required sound
transmission rating. Title 24.
Provide insulation in walls and ceiling to
achieve STC of 50 between garage and living
area if garage use is not controlled by
resident. Title 24.
ENERGY CONSERVATION
Provide plans, calculations and worksheets to
show compliance with current energy standards.
The regulations require a properly completed
and properly signed Form CF-1R to be either
imprinted on the plans, taped to the plans or
"sticky backed" on the plans, to allow the
building inspector to readily compare the
actual construction with the requirements of
the approved energy design.
All energy items shown on the plans must be in
agreement with the information shown on the
properly completed Form CF-1R.
Specify on the building plans all of the
mandatory energy conservation requirements as
listed on the enclosure titled, "Mandatory
Energy Conservation Requirements".
Show the make, model and efficiency of the
space heating (or cooling) system and provide
heat loss calculations if the output exceeds
45,000 BTU/Hr.
\lf,. For room additions, show that the glazing area
of the addition does not exceed 16% of the
newly-conditioned floor area, plus glazing
removed or relocated due to the addition.
IT/' Provide fluorescent general lighting in
kitchen(s) per CAC, Title 24, 2-5352(J).
CARLSBAD S.F.D. & DUPLEX SUPPLEMENT
Energy conservation
7.
design should be for Zone
Floor drains
policy).
must have auto-prime (city
Note exhaust fans cannot be ductless type
(city policy).
New residential units must be pre-plumbed for
future solar water heating. Note "two roof
jacks must be installed" where the water
heater is in the one story garage and directly
below the most south facing roof (City
Ordinance No. 8093).
Note "two 3/4" copper pipes must be installed
to the most convenient future solar panel
location when the water heater is not in a one
story garage and is not directly below the
most south facing roof. (City Ordinance No.
8093).
All piping for present or future solar water
heating must be insulated when in areas that
,are not heated or cooled by mechanical means
(city policy).
Incorporate the waterproofing details, on the
attached Policy 80-8, where interior living
space occurs below grade at the masonry
wall(s).
Show on the Title Sheet on the plans, the
information required by the attached
Developmental Services Sheet 112383.
All new residential buildings, including
additions, require a soils report. Please
submit two copies. Exception: If a room
addition is limited to one story and 1000 sq.
ft. in area, then a soils report is not
required. Esgil Corporation will advise the
City to place their soils notice stamp on the
plans.
Heavy timber framing, minimum 6" x 10" beams
and minimum 8" x 8" post, for the structural
beam and column supporting the fire separation
between the garage and living area above, is
acceptable if shown on the plans. (city
policy).
2/26/90 10
18/
/'
All structures require a Class B roof covering, Enclosures:
except room additions. If a room addition •—r><c.covers all of the existing building (2nd story 1. V-O
addition), then the above exception doesn't
apply.
City Ordinance 9792 requires two parking
spaces/unit with clear area of 20'x20' i.e. no
washing machines, etc. Show compliance. 3_.
All chimneys attached to any appliance or
fireplace that burns solid fuel shall be
equipped with an approved spark arrester. The
net free area of the spark arrester shall be
not less than four times the net free ara of
the outlet of the chimney. The spark arrester
screen shall have heat and corrosion resistance
equivalent to 12 gauge wire, 19 gauge
galvanized wire or 24 gauge stainless steel.
Openings shall not permit the passage of
spheres having a diameter larger than 1/2-inch
and shall not block the passage of spheres
having a diameter of less than 3/8-inch.
MISCELLANEOUS
Please see additional corrections, or remarks,
on the following page.
To speed up the recheck process, note on this
list (or a copy) where each correction item has
been addressed, i.e., plan sheet, note or
detail number, calculation page, etc.
190^ Please indicate here if any changes have been
made to the plans that are not a result of
corrections from this list. If there are other
changes, please briefly describe them and where
they are located in the plans.
Have changes been made to the plans not
resulting from this correction list? Please
check.
Yes No
The City of Carlsbad has contracted with Esgil
Corporation located at 9320 Chesapeake Drive, Suite
208, San Diego, California 92123; telephone number
619/560-1468, to perform the plan check for your
project. If you have any questions regarding these
plan check items, please contact
"3Ti
at Esgil Corporation. If you have any questions
regarding City Building permit procedures, please
contact Carter Darnell at the City of Carlsbad, 2075
Las Palmas Dr., telephone 619/438-1161.
Thank you.
2/14/90 11
DEVELOPMENTAL
SERVICES
BUILDING DEPARTMENT
Op of
1200 ELM AVENUE
CARLSBAD. CA
THE INFORMATION LISTED BELOW MUST BE SHOWN ON THE TITLE SHEET OF THE PLANS
FOR YOUR SINGLE FAMILY DWELLING
Site Address
Legal Description
Assessor's Parcel Number •
Quantity of Grading in cubic yards
Contact Person - Name and daytime Phone Number
Circle any Planning Commission or City Council Action on this Property:
Variance, Conditional Use Permit, Tract or Parcel Map, Zone Change,
Planned Development, Redevelopment Permit, Specific PJ'an, Site
Development Plan
PLAN CHECK NUMBER
cd 112383
Prepared byt
Jurisdiction CARLSBAD
VALUATION AND PLAN CHECK FEE
Bldg. Dept.
Esgil
PLAN CHECK NO.
BUILDING ADDRESS
APPLICANT/CONTACT l/Vff2 . £ft-rz.ci 4
BUILDING OCCUPANCY £ -
TYPE OF CONSTRUCTION
PHONE NO. ~7 2-3 I 6"2
DESIGNER PHONE "
CONTRACTOR PHONE
BUILDING PORTION
K-^»O Lyuin^^
Air Conditioning
Commercial
Residential
Res. or Conun.
Fire Sprinklers
Total Value
BUILDING AREA
^~44 (
VALUATION
MULTIPLIER
, ^,OQ
@
@
-e
VALUE
* 3^6,8
^
y
3^, lc.S
Building Permit Tee $
Plan Check Fee $
COMMENTS;
SHEET OF 12/87
LOTH MAP42^5> WOVJifrg TF.PP44E R^C n
r'lsj x* BUILDING PLANCHECK
Q I' ENGINEERING CHECKLIST
«J r~
?n <». DATE: )Z QCT 9Q 0 ITEM COMPLETE
PLANCHECK NO.SQ-lD^i Vy ITEM INCOMPLETE -
O , NEEDS YOUR ACTION
1 2 3 /ZR1 CYNJTH/fl L./S/
S N R . X ITEM SELECTED
TDD AP Nl I 5cr> ""• 2..1?O '-" I <
C C C PROJECT ID:
H H H
E E E LEGAL REQUIREMENTS
C C C
K K K Site Plan
'—' 1 Provide a fully dimensioned site plan drawn to scale. Show
north arrow, property Line s.._£asementsL, exi stinqand proposed
structures, streets, (exiting street improvement), right-of-
way width and dimensioned~snetbacks" ' •
'—' '—' 2. Show on site plan: Finish floor elevations, pad elevations,
elevations of finish grade adjacent to building, existing
topographical lines, existing^and—pjcoposed slopes, driveway
with percent (%) grade and (drainage patter ins).—- -- ^**
'—' '—' 3. Provide legal description and Assessors Parcel Number.
Discretionary Approval Compliance
4. No Discretionary approvals were required.
Project complies with all Engineering Conditions of Approval
for Project No. .
Project does not comply with the following Engineering
Conditions of Approval for Project No.
Conditions complied with by: Date:.
Field Review
7. Field review completed. No issues raised.
8. Field Review completed. The following issues or discrepancies
with the site plan were found:
A. Site lacks adequate public improvements.
B. Existing drainage improvements not shown or in conflict
with site plan.
C. Site is served by overhead power lines.
D. Grading is required to access site, create pad or provide
for ultimate street improvement.
FRM0010.DH 08/29/89
Site access visibility problems exist. Provide onsite
turnaround or engineered solution to problem.
Other:
Dedication Requirements
_9. No dedication required.
.10. Dedication required. Please have a registered Civil Engineer
or Land Surveyor prepare the appropriate legal description
together with an 8V' x 11" plat map and submit with a title
report and the required processing fee. All easement documents
must be approved and signed by owner(s) prior to issuance of
Building Permit. The description of the dedication is as
fol1ows:
Dedication completed, Date By
Improvement Requirements
.11. No public improvements required. SPECIAL NOTE: Damaged or
defective improvements found adjacent to building site must
be repaired to the satisfaction of the City inspector prior
to occupancy.
.12. Public improvements required. This project requires
construction of public improvements pursuant to Section 18.40
of the City Code. Please have a registered Civil Engineer
prepare appropriate improvement plans and submit for separate
plancheck process through the Engineering Department.
Improvement plans must be approved, appropriate securities
posted and fees paid prior to issuance of permit. The required
improvements are:
Improvement plans signed, Date:.By:.
FRM0010.DH 08/29/89
OP O/ERMB90 UTILITIES
13. Improvements are required. Construction of the public
improvements may be deferred in accordance with Section 18.40
of the City Code. Please submit a letter requesting deferral
of the required improvements together with a recent title
report on the property and the appropriate processing fee so
we may prepare the necessary Future Improvement Agreement
The Future Improvement Agreement must be signed, notarized and
approved by the City prior to issuance of a Building Permit.
Future Improvement Agreement completed, Date
By:
Grading Requirements
13a. Inadequate information available on site plan to make a
determination on grading requirements. Please provide more
detailed proposed and existing elevations and contours.
Include accurate estimates of the grading quantities (cut,
fill, import, export).
14. No grading required as determined by the information provided
on the site plan
15. Grading Permit required A separate grading plan prepared by
a registered Civil Engineer must be submitted for separate
plan check and approval through the Engineering Department
NOTE The Grading Permit must be issued and grading
substantially complete and found acceptable to the City
Inspector prior to issuance of Building Permits.
Grading Inspector sign off. Date: By:
Miscellaneous Permits
>/ 16. Right-of-Way Permit not required.
17. Right-of-Way Permit required. A separate Right-of-Way Permit
issued by the Engineering Department is required for the
fol1owi ng:
y is.Sewer Permit is not required.
.19. Sewer Permit is required. A Sewer Permit is required
concurrent with Building Permit issuance. The fee required
is noted below in the fees section.
.20. Industrial Waste Permit is not required.
FRM0010.DH 08/29/8S
.21. Industrial Waste Permit is required. Applicant must complete
Industrial Waste Permit Applicantion Form and submit for City
approval prior to issuance of Building Permits. Permits must
be issued prior to occupancy.
Industrial Waste Permit accepted -
Date: By:
Fees Required
M/fl 22. Park-in-Lieu Fee
Quadrant: Fee per Unit: Total Fee:.
M/A 23. Traffic Impact Fee
Fee Per Unit: Total Fee:
M/A 24. Bridge and Thoroughfare Fee
Fee per Unit: Total Fee-
M/A 25 Public Facilities Fee required.
N./A 26 Facilities Management Fee Zone: Fee
M/fl 27 Sewer Fees Permit No EDU's.
Fee.
N/A 28 Sewer Lateral required.
Fee:
REMARKS: SfTE.P(JW 60£S MOT /=&REE W/TH MflP
2V SHOW EKISDMC; 4&EQ
ENGINEERING AUTHORIZATION TO ISSUE PERMIT
BY: Date:
EXEMPTED FROM SlOEWAU^ Rg? D
FRM0010.DH 08/29/89
Plan Check No
Planner TV*"-
PLANNING CHECKLIST
- /f ?/ Address /°^7 APN - 17
phone 438-1161
N.^
rt
>;. 9
CJ \v QJ OJ
<00
I"
(Name)
Type of Project and Use S- ^
Zone A" I Facilities Management Zone
c\
Legend
sf
000Q* <l> (Uj: jc -Cu LJ o
Q. Q. Q.
Item Complete
Item Incomplete - Needs your action
1, 2, 3 Number in circle indicates plancheck number where deficiency was
identified
D Environmental Review Required' YES NO J_ TYPE
DATE OF COMPLETION
Compliance with conditions of approvaP If not, state conditions which require action
Conditions of Approval
Discretionary Action Required YES NO ^ TYPE
APPROVAL/RESO NO
PROJECT NO
DATE
OTHER RELATED CASES
Compliance with conditions of approval? If not, state conditions which require action
Conditions of Approval
D Coastal YES NO DATE OF APPROVAL.
Compliance with conditions of approvaP If not, state conditions which require action
Conditions of Approval
Landscape Plan Required YES NO
See attached submittal requirements for landscape plans
Site Plan-
n
D
Zoning
m
3
4
Provide a Jully dimensioned site plan drawn-44>_scal&--^how]^Nprth
arrow/^roperty line§\ easements, existing and proposed structures,
streets, eixistmg street improvements, right-of-way width and
dimensioned setbacks
Show on Site Plan Finish floor elevations, elevations of finish grade
adjacent to building, existing topographical lines, existing and proposed
slopes and dnveway
Provide legal description of property
Provide assessor's parcel number
Setbacks
Front
Int Side:
Street Side
Rear
/
D 2 Lot coverage
D 3 Height
/
L~H 4 Parking
^H Additional Comments >ru/-ff ^y
Required
Required
Required
Required
Required
Required
Spaces Required
Guest Spaces Required
W Shown J3
5 f Shown 1 fc '
-^~ Shown
/£> ' Shown "3> Y '
7 Of* Shown 0.
O fe Shown ^^
O.fl-' Shown <^^
Shown
/ci/ry / fioote 'j
fls»fSrh /,^J?<$ / CA*' + cUt-fr^.^e Lt-4- L>«_fKS v-,A/ f>s0pf;4y h^s
Co(rec -/W /S/0 ' scad-e &( b" \J-i\\ zl&^h'o*) ^/Vci fJarfa Aridis
Lo-f Cojesoi^tL, <-«',> 4~ h diWrJt+fok cJ^^~ +° fDVulfa fr»fi-er+y
///i^f ' ' '
OK TO ISSUE DATE
c: Data Entry PLNCK FRM
\^1-ft
^\
*- *1
L J
10GO
—4
?
?
^
S