Loading...
HomeMy WebLinkAbout1305 BULRUSH CT; ; CB971512; PermitBUILDING PERMIT Permit No: CB971512 97/23/97 10: 51 Project No: A9701940 Page 1 of 1 Development No: DEV89028 Job Address: 1305 BULRUSH CT Suite: Permit Type: SINGLE FAMILY DWLNG - DETACHED Parcel No: 215-850-17-00 Lot#: 17 Valuation: 269,156 Construction Type: VN Occupancy Group: Reference#: CT90-38 Status: ISSUED Description: 3252 SF+701 GAR,PLAN3,PHASE 8 Applied: 04/14/97 : MARFIORE,TAYLOR WOODROW,CT9038,PA 26 N Apr/Issue: 07/23/97 Entered By: RMA Appl/Ownr : TAYLOR WOODROW HOMES 714-581-2626 24461 RIDGE ROUTE LAGUNA HILLS CA 92718 Plan Check Numbers > ORIG 941167,PCK 970873 *A* Fees Required *** *** Fees Collected & Credits *** Adjustments: .oo Fees : Total Fees: 350.00 14,568.83 Fee description Ext fee Data ___------------_- ----------------- Number of Bedroo 5.00 Number of Bathroom 3.50 Building Permit 1235.00 Plan Check 803.00 27.00 Strong Motion Fee Enter "Y" to Auto 4899.00 Y or manually ente 540.00 Payoff Fee for CF 4698.83 * BUILDING TOTAL 12202.83 Enter #Units & C 2400.00 D5/8 Enter "Y" for Plumbi 20.00 Y Each Plumbing Fixtur 133.00 15.00 Each Building Sewer Each Install/Repair Water 7.00 Each Water Heater and/or 7.00 Gas Piping System 7.00 Each Vacuum Breaker 14.00 * PLUMBING TOTAL 203.00 Enter "Y" for Electric Issue Fee > 10.00 Y 50.00 * ELECTRICAL TOTAL 60.00 15.00 Y Enter 'Y' for Mechanical Issue Fee> Each Install Fireplace > 1 6.50 6.50 13.00 Each Exhaust Fan > 2 6.50 * MECHANICAL TOTAL 53.00 Single Phase Per AMP > 200 .25 Install Furn/Ducts/Heat Pumps > 1 9.00 9.00 Each Install/Reloc Vent > 2 4.50 9.00 c I CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING CMWD WATER PLAN CHECK#: CB971512 DATE : PERMIT#: CB971512 PERMIT PROJECT NAME: 3252 SF+701 GAR,PLAN3,PHASE 8 MARFIORE,TAYLOR WoODROW,CT9038,PA 26 N ADDRESS: 1305 BULRUSH CT Lot# 17 CONTACT PERSON/PHONE#: C/STEVE/930-0296 SEWER DIST: CA WATER DIST: CA 12/16/97 TYPE: SFD "J INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - COMMENTS : FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING CMWD WATER PLAN CHECK#: CB971512 PERMIT#: CB971512 PROJECT NAME: 3252 SF+701 GAR,PLAN3,PHASE 8 MARFIORE,TAYLOR WOODROW,CT9038,PA 26 N ADDRESS: 1305 BULRUSH CT Lot# DATE: 12/16/97 PERMIT TYPE: SFD CONTACT PERSON/PHONE#: C/STEVE/930-0296 SEWER DIST: CA WATER DIST: CA INSPECTED DATE BY: e- INSPECTED: APPROVED & INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE lrtrFL”ING CMWD WATER PLAN CHECK#: CB971512 DATE: 12/16/97 PERMIT#: CB971512 PERMIT TYPE: SFD PROJECT NAME: 3252 SF+701 GAR,PLAN3,PHASE 8 MARFIORE,TAYLOR WOODROW,CT9038,PA 26 N ADDRESS: 1305 BULRUSH CT Lot# 17 CONTACT PERSON/PHONE#: C/STEWE/930-0296 SEWER DIST: CA WATER DIST: CA INSP ATE BY : NSPECTED: /2b j ~-~$PPROVED DISAPPROVED - INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - COMMENTS : FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING CMWD WATER PLAN CHECK#: CB971512 DATE: 12/16/97 PERMIT#: CB971512 PERMIT TYPE: SFD PROJECT NAME: 3252 SF+701 GAR,PLAN3,PHASE 8 MARFIORE,TAYLOR WOODROW,CT9038,PA 26 N ADDRESS: 1305 BULRUSH CT Lot# 17 CONTACT PERSON/PHONE#: C/STEVE/930-0296 SEWER DIST: CA WATER DIST: CA INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - COMMENTS : FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING CMWD "WATER PLAN CHECK#: CB971512 DATE: 12/16/97 PERMIT#: CB971512 PERMIT TYPE: SFD PROJECT NAME: 3252 SF+701 GAR,PLAN3,PHASE 8 MARFIORE,TAYU)R WOODROW,CT9038,PA 26 N ADDRESS: 1305 BULRUSH CT Lot# 17 CONTACT PERSON/PHONE#: C/STEVE/930-0296 SEWER DIST: CA WATER DIST: CA DATE INSPECTED : /2,/7-"77 APPROVED DISAPPROVED - INSPECTED BY: INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971512 FOR 12/19/97 INSPECTOR AREA RB DESCRIPTION: 3252 SF+701 GAR,PLAN3,PHASE 8 PLANCK# ORIG 941 MARFIORE,TAYLOR WOODROW,CT9038,PA 26 N OCC GRP TYPE: SFD JOB ADDRESS: 1305 BULRUSH CT APPLICANT: TAYLOR WOODROW HOMES CONTRACTOR: OWNER: REMARKS: C/TAYLOR WOOD/ EARLY AM PLEASE SPECIAL INSTRUCT: TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE CB971722 =IN CB973833 RAD CD 19 29 39 49 LVL DESCRIPTION ST Final Structural PL Final Plumbing EL Final Electrical ME Final Mechanical CONSTR. TYPE VN STE : LOT: 17 PHONE: 714-581-2626 PHONE : PHONE : INSPECTOR STATUS ISSUED ISSUED ACT COMMENTS z ***** INSPECTION HISTORY ***** DATE 121097 120597 110597 110597 110597 110497 110497 110497 110397 102997 102497 102297 102097 092497 092497 092297 091897 080597 080197 072497 DESCRIPTION Final Electrical Final Electrical Exterior Lath/Drywall Gas/Test/Repairs Interior Lath/Drywall Exterior Lath/Drywall Gas/Test/Repairs Interior Lath/Drywall Interior Lath/Drywall Insulation Rough Combo Rough Combo Rough Combo Roof Sheathing/Ext Shear Roof Sheathing/Ext Shear Roof Sheathing/Ext Shear Roof/Reroof Underground Combo Underground Combo Underground/Under Floor ACT AP co NS AP AP AP AP co NR AP AP CA co AP AP NS NR AP co AP INSP COMMENTS RB RB RB RB RB RB RB RB RB RB PD PD PD PD PD PD PD PD PD PD BY FRANK --- RSTM 1232, C138, C143, C172, 12173, C231, C1864 --- CONCRETE: X GROUT: MORTRR: SHOTCRETE: CORES: GUN I TE : RDDRESS: 1385 EULLRUSH COURT JOE #: 7288 DFSTE: 9/23/97 JOB NRME: MRR FIORE R. LRU PERMIT #: 971512 ISSUED EY: CFSRLSERD CONTRRCTOR: TFSYLOR WOODROW SUE CONTRRCTOR: SILVERRDO LOCFSTION IN STRUCTURE: LOT 17 S/W SECTION CONCRETE SUPPLIER: SUF’ERIOR PLFSNT: 2 MIX #: 34791 TYPE OF CEMENT: I1 FSDMIXTURE: POZZ TICKET #: 218422 SLUMP: 5” WRTER RDDED: lizr FSIR TEMP: 98 CONCRETE TEMP: 85 MIXING TIME: 58 TIME CFSST: 9:35 RRCHITECT: ROBERT HIDEY ENGINEER: G~UUIS _I_--_____--_____--_------------------------------------------------------------ ----1-----------1---___________________I---------------------------------------- THIS REPORT SHRLL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT THE RPROWFIL OF SIT1 --------------------_____^_______ SRMPLES CRST BY OTHERS : LFSB. MRNRGER RSTM C39 EREFSKS Fs= cone E= cone and split C= cone D= shear E= columnar- r( "> SOUTHWEST INSPECTION & TESTXNG I INSPECTION SUMMARY- LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS. ETC. INCLUDES INFORMATION ABOUT - AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER. TYPE 6 DENT. NO'S OF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS (WELD MADE H.T. BOLTS TORQUED) CHECKED; ETC. I 1 j i ! ~- 6 A 0 91 I>?/ I CERTIFICATION OF COMPLIANCE PAGE .- tf OF - I HEREBY CERTlFV THAT I HAVE INSPECTED TO THE BEST OF MY KNOWLEDQE ML OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAM FOUND THIS mXIK TO COMPLY WlTH THE APPROVED PLANS. SPECIFICATIONS. AND APPLICABLE SECTIONS OF THE QOMRNING BUILDIN0 LAWS. C".l i.# p..1 noon hour will k n 8 SI&"ARE OF AEGlSTERED INSPECTOR plK/q#&&tlt. 477 0&a?? SPEUALTY N6. MKNCI ~JHITE - OFFICE COPY, CANARY - ACCOUNTING COPY: PINK - INSPECTOR'S cow, GOLDENROD IJOB%TE cow - . __ - - . . ,. ~. .d &@-l I LEIGHTON AND ASSOCIATES, INC. Plan File No.: ,Permit No.: UnitPh Observation Summary Initials A representative of Leighton and Associates observed onsite soil conditions. Soil conditions at the site are substantially in conformance with those assumed in the geotechnical report. A representative of Leighton and Associates observed and measured footing excavation depmdth. Footing excavations extend to proper depth and bearing strata and are in general conformance with recommendations of the geotechnid rep& from slope face. The setback was in general accordance with the recommendations of the geotechnid report. 7 1 -stl.r?Date MG' M Initials 7 \ +at63 Date v k Initials A representative of Leighton and Associates measured footing setback 1 \\*+I Date "v\f fi Initials cI?r~p:~~ )JJT.F.~:~ QLLQM -i\* +krDate Notes to SuperintendeWForeman 1. Footing excavations should be cleaned of loose debris and thoroughly moistened just prior to placing concrete. 2. Based on expansion potential of underlying soils, presoaking of soil below slabs may be recommended. Consult the geotechnid report for presoaking recommendations. We note that clayey soils may take an extended period of time and the contractor should schedule accordingly. 3. In the event of a site change subsequent to our footing observation and prior to concrete placement (i-e., heavy rain, etc.), we should be contacted to perform additional site observations. Notes to Building Inspector 1. Soil compaction test results, including depth of fill, relative compaction, bearing values, and soil expansion index test results are contained in the &-Graded Geotechnical Report provided at the completion of grading. TULY "SI I IT47 Date (6 19) 292-8030 (800) 447-2626 3934 MURPHY CANYON ROAD, SUITE 8205, SAN DIEGO, CA 92 I23 FAX (6 19) 292-077 I