Loading...
HomeMy WebLinkAbout1316 CORVIDAE ST; ; CB141438; Permit07-15-2014 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Pool Permit Permit No: CB141438 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: PC #: Project Title: 1316 CORVIDAE ST CBAD POOL 2156901000 Lot#: $3,909.00 Construction Type: BROWNLEE RES- 96 SF POOL/SPA 0 NEW Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: ISSUED 06/23/2014 RMA 07/15/2014 07/15/2014 Applicant: Owner: CALIFORNIA POOLS INC DBA CALIFORNIA POOLS & SPAS BROWNLEE DAVID G&DEANNA N LIVING TRUST 04-19-06 3106 EGARVEY AVE S WESTCOVINACA 91791-2344 760-744-8868 1316 CORVIDAE ST CARLSBAD CA 92011 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Electrical Fee Plumbing Fee Strong Motion Fee Green Bldg Standards (SB1473) Fee Renewal Fee Add'l Renewal Fee Other Building Fee Additional Fees $68.07 $0.00 $47.65 $0.00 $33.00 $33.00 $1.00 $1.00 $0.00 $0.00 $0.00 $0.00 TOTAL PERMIT FEES $183.72 Total Fees: $183.72 Total Payments To Date: $183.72 Balance Due: $0.00 Inspector: FINAL APPROVAL Date: Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter coiiectiveiy referred to as "fees/exactions," You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3,32.030. Failure to timely follow that procedure wiii bar any subsequent legal action to attacl<, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have oreviouslv been given a NOTICE similar to this, or as to which the statute of limitations has oreviousiv othenwise expired. 07-15-2014 City of Carlsbad 1635 Faraday Av Carlsbad.CA 92008 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No:SW140212 Job Address: Permit Type: Parcel No: Reference #: CB#: Project Title: Applicant: 1316 CORVIDAE ST CBAD SWPPP 2156901000 CB141438 BROWNLEE POOL/SPA Lot#: Owner: Status: Applied: Entered By: Issued: Inspect Area: Tier: Priority: ISSUED 06/23/2014 RMA 07/15/2014 1 L CALIFORNIA POOLS INC DBA CALIFORNIA POOLS & SPAS BROWNLEE DAVID G&DEANNA N LIVING TRUST 04-19-06 3106 E GARVEY AVE S WESTCOVINACA 91791-2344 760-744-8868 1316 CORVIDAE ST CARLSBAD CA 92011 Emergency Contact: MIKE WELCH 760 744-8868 SWPPP Plan Check SWPPP Inspections Additional Fees $48.00 $57.00 $0.00 TOTAL PERMIT FEES $105.00 Total Fees: $105.00 Total Payments To Date: $105.00 Balance Due: $0.00 FINAL APPROVAL SIGNATUREJ_AyU THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: • PUNNING IENGINEERING • BUILDING DFIRE • HEALTH • HAZMAT/APCD Plan Check No ( 'A, / ^ / /Jj^P^ CITY OF CARLSBAD Building Permit Appiication 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax:760-602-8558 email: building@carlsbadca.gov >>> . www.carlsbadca.gov (— Est. Value 3M Plan Ck. Deposit^ Y 7> ^ 5^ Date ^ /^^AM SWPPP JOB ADDRESS TLOT* I PHASE # I # OF UNITS | # BEDROOMS SUITE*/SPACE«/UNrT* CT/PROJECT # # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE OCCGROUP DESCRIPTION OF WORK: /nc/ude Square Feet of Affected Areafs; EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YESr~|# N0| I AIR CONDITIONING YES QNO I I FlRESPRINKLERS YES I |NO| I APPLICANT NAME Prinarv Contact PROPERTY OVUMER NAME ADDRESS ADDRESS CITY STATE ZIP FAX EMAIL DESIGN PROFESSIONAL CONTRA STATE ADDRESS ADDRESS IDW>&.^ (- CITY. PHONE FAX EMAIL r —• IC>0 I 5 iGfc^S '^'''^ BUS. LIC.# EMAIL STATE requires I (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuantto the provisions ofthe Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of me Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the appiicantto a civil penalty of not more than five hundred dollars ($500)). WORKERS' COMPENSATION Workers' Compensation Declaration: / hereby affimi under penalty ofpeijury one ofthe following declaiations: |iave and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the pertormance of the work for wtiich this penult is issued. Tl have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the perfomiance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number ane: Insurance Co. Policy No. Expiration Date This seciion need not be completed if the permit is for one hundred doiiars ($100) or less. I I Certificate of Exemption: I certify that in the^rformance of the work for which this pemiit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of Califomia. WARNING: Failure to secure wowers^mpensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one huiulred thousar ^ dollars (&100,000), in addition to the cost of compensation, damages as pi^vided for in Section 3706oftj)ALjl;ar cgde, interest and attomey'yees.^ CONTRACTOR SIGNATURE JL ^ NjnAGENT DATE OWNER-BUILDS R DECLARATION 1/ 9-5 l4 (hereby affimi that / am exempt fram Contractor's Ucense Law for the follomng reason: I I I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I I I, as owner of the property, am exclusively contracting with Iteensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contrxtor's License Law does not apply to an owner of property who buiids or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I I I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the praposed praperty improvement. ^Yes I iNo 2. i (have / have not) signed an application for a building pemiit for the proposed vrork. 3.1 have contracted with the following person (fimi) to provide the praposed constnjction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the foiiowing person to coordinate, supervise and pravide the major wori< (include name / address / phone / contractors' license number): 5.1 v«ll pravide some of the work, but I have contracted (hired) the following persons to provide the wori( indicated (include name / address / phone / type of work): ^PROPERTY OWNER SIGNATURE •AGENT DATE PLETE THIS SECTION FOR N O N • R E S I O E N T t A L BUILOli Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration fomi or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? • Yes • No is the applicant or future building occupant required to obtain a permit fram the air pollution control district or air quality management district? • Yes O No Is the facility to be constracted within 1,000 feet of the outer boundary of a school site? • Yes O No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLiCANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CON $ TR:;jyL^:Tt'0::N;i-|.JirN,D I N;J I hereby affirm that tfiere is a construction lending agency for ttie performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address LICANT ClgTiFICATlON I certify that I have read the applkation and state thatthe above information is conect and that tlie inforniation on the plans is accurate. I agree to comply with all Cify ordinances and State laws relating to building constnjction. I hereby authorize reprBsentative ofthe City of Catlsbad to enter upon the above mentioned property for inspectbn purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL UABILmES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA pernilt Is required for excavations over 5'0' deep andAxilition or constaiction of stmctures over 3 stories in height. \ EXPIRATION: Every pennit issued by the Buikiing Oflicial under the wovisbns of this Code shall expire by limitation and become nut and void If the buiWin^r wDri< aulborized by such permit is not commenced wilhin 180 days Horn the date of such permit or if the buikling or work autholzed by such permit is suspended or abandoned at any time afler the «ort( is commenckd for a period of 180 days (Section 106.4.4 Unifonn Building Code). I APPLICANT'S SIGNATURE '^ DATE Inspection List Permit*: CB141438 Type: POOL BROWNLEE RES- 96 SF POOL/SPA Date Inspection Item Inspector Act Comments 02/23/2015 55 Fence/Pre-Plaster -Rl BROWNLEE RES 02/23/2015 55 Fence/Pre-Plaster PD AP 02/23/2015 59 Final Pool PD AP 02/23/2015 59 Final Pool PD AP 12/03/2014 51 Excav/Steel/Bonding/Fence PD AP Eco Bond 09/25/2014 52 Underground Plumbing PY AP 09/05/2014 51 Excav/Steel/Bonding/Fence MC AP 09/05/2014 52 Underground Plumbing MC PA STUB OUT AT POOL WALL 09/05/2014 53 Electric/Conduit/Wiring MC PA STUB OUT AT POOL WALL IVlonday, February 23, 2015 Page 1 of 1 PLAN CHECK PLAN CHECK Community & Economic ^ CITY OF REVIEW Development Department 1635 Faraday Avenue CARLSBAD TRANSMITTAL Carlsbad CA 92008 www.carlsbadca.gov DATE: 07/09/2014 PROJECT NAME: Brownlee Pool & .Spa PLAN CHECK NO: CB 141438 SET#: 1 ADDRESS: 1316 Coi vidac St VALUATION:$3,909 SCOPE OF WORK: 96 SF Pool and Spa PROJECT ID: APN: 215-690-1 0^1 check review is complete and lias been APPROVED by: l_AND DEVELOPIVIENT ENGINEERING DIVISION Inspection by the CM&I division is required: Yes X No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: carriejones@hotmail.coni r^^. PUNNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-6012-4665 | \/ Linda Ontiveros /\ 760-602-2773 Linda.Ontiveros@carlsbadca.gov : Remarks: CB141438 Brownlee Pool & Spa Instructions Plot easement on site plan. Outstanding issues will he marked with X Items that conform to permit requirements are marked with / -or- have intentionally been left blank. 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show: / Nofth arrow y/^liisimg & proposed structures V'^^/Property line dimensions Show on site plan: / Drainage patterns / Existing & proposed slopes Existing topography Retaining Walls (location and height) / Indicate what will happen with soil excavated from pool area. Include on title sheet: / Site address / Assessor's parcel number / Legal description/lot number Grading: Quantities of Cut Fill Import Export Project does not comply with the following engineering conditions of approval for project no: Conditions were complies with by: Date: Lot/Map No.: LOT45/13141 Subdivision/Tract: CT 90-36 Reference No(s): DWG 329-6A E-37 Page 2 of 4 REV 6/2012 CB141438 Brownlee Pool & Spa 2. GRADING PERMIT REQUIREMENTS The conditions that require a grading permit are found in Section 11.06.030 of the Municipal Code. Inadequate Information available on site plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial). This information must be included on the plans. If no grading is proposed write: "NO GRADING" Minor Grading Permit required. NOTE: The grading permit must be issued and grading approval obtained prior to issuance of a building permit. A separate grading plan prepared a registered civil engineer must be submitted together with the completed application form attached. / No grading permit required. 3. MISCELLANEOUS PERMITS RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work adjacent to the public right-of-way. A separate right-of-way issued by the engineering division is required for the following: Please complete attached right-of-way application form and return to the engineering department together with the requirements on the attached right-of-way checklist, at the time of resubmittal. Right-of-way permit and pool permit will be issued simultaneously. E-37 Page 3 of 4 REV 6/2012 CB141438 Brownlee Pool & Spa 4. STORM WATER Construction Compliance / Project Threat Assessment Form complete. Enclosed Project Threat Assessment Form incomplete. / Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached form and return (SW "-212 ) Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city. Post-Development (SUSMP) Compliance / Storm Water Standards Questionnaire compiete. Storm Water Standards Questionnaire incomplete. Please make the corrections, re-sign the questionnaire and resubmit with next submittal. Project is subject to Standard Storm Water Requirements. See city Standard Urban Storm Water Management Plan (SUSMP) for reference. http://www.carlsbadca.qov/business/buildinq/Documents/EnqStandsw-stds-voi4-ch2.pdf Project needs to incorporate low impact development strategies throughout in one or more of the following ways: Rainwater harvesting (rain barrels or cistern) Vegetated Roof Bio-retentions cell/rain garden Pervious pavement/pavers Flow-through planter/vegetated or rock drip line Vegetated swales or rock infiltration swales Downspouts disconnect and discharge over landscape Other: Attachments: Engineering Application Storm Water Form Rlght-of-Way Application/Info Reference Documents / E-37 Page 4 of 4 REV 6/01/12 * STORM WATER Development Services CITY OF CARLSBAD COMPLIANCE ASSESSMENT B-24 Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.Eov am applying to the City of Carlsbad for the following type(s) of construction permit: • Building Permit • Right-of-Way Permit • My project is categorically EXEMPT from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it only requires issuance of one or more of the following permit types: Electrical Fire Additional Fire Alarm Fixed Systems Mechanical Mobile Home Plumbing Patio/Deck Photo Voltaic Re-Roofing Sign Spa-Factory Sprinkler Water Discharge Project Storm Water Threat Assessment Criteria'* No Threat Assessment Criteria • My project qualifies as NO THREAT and is exempt from the requirement to prepare a stonn water pollution prevention plan (SWPPP) because it meets the 'no threat" assessment criteria on the City's Project Threat /\ssessment Worksheet for Determination of Construction SWPPP Tier Level. My project does not meet any of the High, Moderate or Low Threat criteria described below. Low Thivat Assessment Criteria My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project meets one or more ofthe following criteria: • Results in some soil disturbance; and/or • Includes outdoor construction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling). 7'/er2 - Moderate Threat Assessment Criteria • My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria: • Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 ofthe Carisbad Municipal Code); or, • Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more ofthe additional following criteria: • Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or • Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or • Disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or • Construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). Tier 3 • • • • Significant Threat Assessment Criteria My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, refueling and maintenance areas: or. My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-stomi water discharge(s). I certify to the best of my knowledge that the above checked statements are true and correct I understand and acknowledge that even though this project does not require preparation of a construction SWPP, I must still adhere to, and at all times during construction activities for the permit type{s) check above comply with the storm water best management practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards. *The City Engineer may authorize minor variances from the Stonn Water Threat Assessment Criteria in special circumstances where it can be shown that a lesser or higher Constmction SWPPP Tier Level is wan'anted. Project ^ddress: 1 /\ ^^ Assessor Parcel No. Ownsjfflwners Authorize^ AgenjMmn»iy^~—s.. Title: V Owner/Owner's Authorized Agept&gpature: Date: City/Concurrence: I W / Date/ J J ^ f ES Y) 111^1 r am B-24 Page 1 of 1 Rev.03/09 CITY OF CARLSBAD CONSTRUCTION THREAT ASSESSMENT WORKSHEET FOR DETERMINATION OF PROJECT'S PERCEIVED THREAT TO STORM WATER QUALITY E-33 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov Construction SWPPP Tier Level Construction Threat Assessment Criteria* Perceived Threat to Storm Water Quality Tiers Tier 3 - Hiati Construction Threat Assessment Criteria High Tiers • Project site is 50 acres or more and grading will occur dunng ttie rainy season • Project site is 1 acre or more in size and is located wittiin ttie Buena Vista or Agua Hedionda Lagoon watershed, inside or within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an ESA • Soil at site is moderately to highly erosive (defined as having a predominance of soils with USDA-NRCS Erosion factors kf greater than or equal to 0.4) • Site slope is 5 to 1 or steeper • Construction is initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). • Owner/contractor received a Storm Water Notice of Violation within past two years High Tiers Tier 3 - Medium Construction Threat Assessment Criteria Medium Tiers • All projects not meeting Tier 3 High Construction Threat Assessment Criteria Medium Tier 2 Tier 2 Hioh Constmction Threat Assessment Criteria • Project is located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an ESA • Soil at site is moderately to highly erosive (defined as having a predominance of soils with USDA-NRCS Erosion factors kf greater than or equal to 0.4) • Site slope is 5 to 1 or steeper • Construction is initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). • Owner/contractor received a Storm Water Notice of Violation within past two years • Site results in one half acre or more of soil disturbance High Tier 2 Tier 2 - Medium Construction Threat Assessment Criteria Medium Tier 2 • All projects not meeting Tier 2 High Construction Threat Assessment Criteria Medium Tierl Tier 1 - Medium Insoection Threat Assessment Criteria Medium Tierl • Project is located within the Buena Vista or Agua Hedionda Lagoon watershed, within or directly adjacent to an environmentally sensitive area (ESA) or discharges directly to an ESA • Soil at site is moderately to highly erosive (defined as having a predominance of soils with USDA-NRCS Erosion factors kf greater than or equal to 0.4) • Site slope is 5 to 1 or steeper • Construction is initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). • Owner/contractor received a Storm Water Notice of Violation within past two years • Site results in one half acre or more of soil disturbance Medium Tierl Tier 1 - Low Insoection Threat Assessment Criteria Low Tierl • All projects not meeting Tier 1 Medium Construction Threat Assessment Criteria Low 1 Exempt - Not Applicable -Exempt *The city engineer may authorize minor variances from the constmction threat assessment criteria in special circumstances where it can be shown that a lesser or higher amount of stomri water compliance inspection is warranted in the opinion of the city engineer E-33 Page 1 of 1 REV 4/30/10 CITY OF CARLSBAD STORM WATER COMPLIANCE FORM TIER 1 CONSTRUCTION SWPPP E-29 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov STORM WATER COMPLIANCE CERTIFICATE My project is nof In a category of permit types exempt from the Construction SWPPP requirements ^ My project Is not located inside or within 200 feet of an environmentally sensitive area with a significant potential for contributing pollutants to nearby receiving waters by way of storrn water runoff or non-storm water discharge(s). My project does not require a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 ofthe Carlsbad Municipal Code) ^ My project will not result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas that meets one or more ofthe additional following criteria: • located within 200 feet of an environmentally sensitive area or the Pacific Ocean; and/or, • disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical; and/or • disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse; and/or • construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT ALL OF THE ABOVE CHECKED STATEMENTS ARE TRUE AND CORRECT. I AM SUBMITTING FOR CITY APPROVAL A TIER 1 CONSTRUCTION SWPPP PREPARED IN ACCORDANCE WITH THE REQUIREMENTS OF CITY STANDARDS. I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PFJACTICABLE TO MINIMIZE THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO MINIMIZE THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND, (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY THE CITY OF CARL3BAD. OWNER(S)/OW«SIER'SAGEN5;NAME (PRINTT^ / / . C^^^ (d^slU OWNER(S)/OWNER'S AGENT NAME (SIGNATURE) DAfTE f I STORM WATER POLLUTION PREVENTION NOTES 1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE FIAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPS WHEN RAIN IS EMINENT. 2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. 3. THE OWNEFl/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEERING OR BUILDING INSPECTOR DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 5. ALL GFIAVEL BAGS SHALL BE BURLAP TYPE WITH 3/4 INCH MINIMUM AGGREGATE. 6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. SPECIAL NOTES PROJECT INFORMATION Site Address: Assessor's Parcel Numb^ \'^'LcfxCr^C:>"^ Project ID: Constmction Permit No.: Estimated Construction Start DateC^ Project Duration Months Emergency Contact Name: 24 hour Phone jency Contact: Perceived Threat to Stonm Water Quality ^ Medium Low If medium box is checked, must attach a site plan sheet showing proposed work area and location of proposed structural BMPs For City Use Only Approved By: Date: Cn/ OF CARLSBAD STANBAHD TIER 1 SWPPP E-29 Page 1 of 3 REV 4/30/10 CITY O F CARLSBAD STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov TO BE COMPLETED FOR REDEVELOPMENT PROJECTS THAT At^EJEfUOfUTLPEymj^^ PROJECTS QNLTL Complete the questions below regarding your redevelopment project: YES NO Does the redevelopment project result in the creation or replacement of impervious surface in an amount of less than 50% ofthe surface area ofthe previously existing development? If you answered "yes," the structural BMP's required for Priority Development Projects apply only to the creation or replacement of impervious surface and not the entire development. Go to step 4, check the "my project meets PDP requirements" box and complete applicant information. If you answered "no," the structural BMP's required for Priority Development Projects apply to the entire development. Go to step 4, check the "my project meets PDP requirements" box and complete applicant information. CHECK THE APPROPRIATE BOX AND COMPLETE APPLICANT INFORMATION My project meets PRIORITY DEVELOPMENT PROJECT (PDP) requirements and must comply with additional stomiwater criteria per the SUSMP and I understand I must prepare a Storm Water Management Plan for submittal at time of application. I understand flow control (hydromodification) requirements may apply to my project. Refer to SUSMP for details. My project does not meet PDP requirements and must only comply with STANDARD STORMWATER REQUIREMENTS per the SUSMP. As part of these requirements, I will incorporate low impact development strategies throughout my project. Applicant Information and Signature Box Applican Applicant Signature: —^ Accessor's Paicel Number(s): , _ , > Appiic^g^^ Date: i4 This Box for/iity Use Only City CoBC/Eirrence: Project ID ^^/^ /(/^/T^ * Environmentally Sensitive Areas include but are not limited to all Clean Water Act Section 303(d) impaired water bodies; areas designated as Areas of Special Biological Significance by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); water bodies designated with the RARE beneficial use by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); areas designated as preserves or their quivalent under the Multi Species Conservation Program within the Cities and County of San Diego; and any other equivalent environmentally sensitive areas which have been identified by the Copemiittees. E-34 Page 3 of 3 Effective 6/27/13 Erosion Control BMPs Sediment Control BMPs Best Management Practice (BMP) Description ^ Geotextiles & Mats Wood Mulching Earth Dikes and Drainage Swales Slope Drains Silt Fence Sediment Trap Check Dam Fiber Rolls Gravel Bag Berm Street Sweeping and Vacuuming Sandbag Bamer Storm Drain Inlet Protection Stabilized Constmction Ingress/Egress Stabilized Constmction Roadway Water Consen/ation Practices Paving and Grinding Ooerations Potable Water/lmgation Vehicle and Equipment Cleanlna Material Delivery and Material Use Stockpile Management Spill Prevention and Control Solid Waste Manaaf>mpnt Hazardous Waste ^anaoement Concrete Waste MananRmpnt CASQA Designation Construction Activity EC-7 EC-8 EC-9 EC-11 SE-1 SE-3 SE-4 SE-5 ^SE-6 SE-7 SE-8 SE-10 TR-1 TR-2 NS-1 NS-3 NS-7 NS-8 WM-1 WM-2 WM-3 WM-4 WM-5 WM-6 WM-8 Grading/Soil Disturbance y ^renching/Excavation / y r^ockpiling DdUing/Boring /Concrete/Asphalt Saw g^ng y 'tJoncrete flatwork Paving Conduit/Pipe Installation Sfucco/Mortar Wor1< "waste Disposal Staging/Lay Down Area Equipment Maintenance and Fueling Hazardous Substance Use/Storage Dewatering Site Access Across Dirt Other (list): Tracking Control BMPs Non-Stonn Water Management BMPs Waste Management and Materials Poiiution Control BMPs Instructions: Begin by reviewing the list of constmction activities and checking the box to the left of any activity that will occur during the proposed constmction. Add any other activity descriptions in the blank activity description boxes provided for that purpose and place a check in the box immediately to the left of the added activity description. For each activity descnribed, pick one or more best management practices (BMPs) from the list located along the top of the form. Then place an X in the box at the place where the activity row intersects with the BMP column. Do this for each activity that was checked off and for each of the selected BMPs selected from the list. For Example - If the project includes site access across dirt, then check the box to the left of "Site Access Across Dirt". Then review the list for something that applies such as "Stabilized Constmction Ingress/Egress" under Tracking Control. Follow along the "Site Access Across Dirf row until you get to the "Stabilized Constmction Ingress/Egress" column and place an X in the box vi/tiere the two meet. As another example say the project included a stockpile that you intend to cover with a plastk: sheet. Since plastic sheeting is not on the list of BMPs, then write in "Cover with Plastic" in the blank column under the heading Erosion Control BMPs. Then place an X In the box where the "Stockpiling" row intersects the new "Cover with Plastic" column. To learn more about what each BMP description means, you may wish to review the BMP Reference Handout prepared to assist applicants in the selection of appropriate Best Management Practice measures. The reference also explains the Califomia Stonnvi/ater Quality Association (CASQA) designation and how to apply the various selected BMPs to a project. E-29 Page 2 of 3 REV 4/30/10 PLANNING DIVISION Development Services Planning Division BUILDING PLAN CHECK Development Services Planning Division CITY OF REVIEW CHECKLIST 1635 Faraday Avenue CARLSBAD P-28 (760) 602-4610 www.carisbadca.eov DATE:-6-2&d:4 PROJECT NAME: PLAN CHECK NO: CB 14-1438 PROJECT ID: SET#: 1 ADDRESS: 1316 Corvidae St APN: 215-690-10-00 This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Sexton A Final Inspection by the Pianning Division is required • Yes ^ No You may also tiave corrections from one or more of ttie divisions listed below. Approval from tiiese divisions may be required prior to the issuance of a building permit. Resubmitted plans stiouid include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: carriejones@hotmail.com For questions or clarifications on the attached checl^list please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 X Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.fiov 1 1 Kathleen Lawrence 760-602-2741 Kath leen. La wrence@ca risbad ca .fiov 1 Greg Ryan 760-602-4663 Grefiorv.Rvan@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Llnda.Ontiveros@carlsbadca.fiov Q Cindy Wong 760-602-4662 Cvnthla.Wonfi@carlsbadca.fiov • • 1 1 Dominic Fieri 760-602-4664 Dominic. Fierl@carlsbadca.fiov Remarks: Plan Check No. CB 14-1438 Address 1316 Corvidae Date 6-25-14 Review # 1 Planner Chris Sexton Phone (760) 602-4624 APN: 215-690-10-00 Type of Project & Use: addition Net Project Density: 1.0 DU/AC Zoning: P-C General Plan: RLM Facilities Managennent Zone: 19 CFD (in/out) #_Date of participation: Remaining net dev acres: (For non-residential development: Type of land use created by this permit: ) REVIEW #: 12 3 Legend: ^ Item Complete • Item Incomplete - Needs your action lEl • • Environmental Review Required: YES • NO • TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: lEI • • Discretionary Action Required: YES • NO • TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Q Q Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES Q NO • CA Coastal Commission Authority? YES • NO O If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): • • Habitat Management Plan Data Entry Completed? YES • NO • If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) • • Inclusionary Housing Fee required: YES • NO • (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES • NO • (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) • • Housing Tracking Form (form P-20) completed: YES • NO • N/A • P-28 Page 2 of 3 07/11 Site Plan: S • • Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. City Council Policy 44 - Neighborhood Architectural Design Guidelines • • 1. Applicability: YES • NO • • • 2. Project complies: YES • NOQ Zoning: • • • • 1. Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: Required. Required Required Required. Required 2. Accessory structure setbacks: Front: Required Interior Side: Required Street Side: Required Rear: Required Structure separation: Required Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown • • 3. Lot Coverage: Required Shown • • 4. Height: Required Shown • • • • • Spaces Required Shown 5. Parking: (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments 1) One of the site plans is not depicting the propertv lines correcting and does not provide anv information about the slopes. Both sites plan need to have the identical information on both plans. OK TO ISSUE AND ENTERED APPROVAL INTO COMPU p-28 Page 3 of 3 07/11