Loading...
HomeMy WebLinkAbout1316 CORVIDAE ST; ; CB951376; Permit49 BUILDING PERMIT DETACHED Page JoV) .Address • 1316 CORVIDAE ST Permit Type SINGLE FAMILY DWLNG Parcel No 215-690-10-00 Valuation- 269,156 Occupancy Group- R3/M1 Description 3253 SF+701 GAR,PLAN 3~PHASE 3 . MARFIORE,TAYLOR WOODROW PA 26-S Suite Permit No Project No Development No CB951376 Ay50203 4 Lot# 45 Reference,: Appl/Ownr TAYLOR WOODROW HOMES 26461 RIDGE ROUTE LACUNA HILLS, CA 92666 Apr/Issue Entered By 714 581-2626 5175 12/15/95 XOi Ol VN ISSUED 11/16/94 12/15/95 RMA * * * Plan Check Number Fees Required *** > 94-H67 *** Fees collected & Credits * * * Fees . Adjustments Total Fees Fee description 14,870 14 00 14,870.14 - Water Fee > Number of Bedrooms Number of Bathrooms Building Permit Plan Check Strong Motion Fee Enter Number of EDU's Enter "Y" to Autocalc P.F F. Enter "Y" to Autocalc T.I.p' ' Payoff Fee for CFD * BUILDING TOTAL \ Enter "Y" for Plumbing Issue Fee ; Each Plumbing Fixture'or Trap ; Each Building Sewer ; Each Install/Repair Water Line ) Each Water Heater and/or Vent ) Gas Piping System > Each Vacuum Breaker > * PLUMBING TOTAL Enter "Y" for Electric Issue Fee > Single Phase Per AMP > * ELECTRICAL TOTAL Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts/Heat Pumps > Each Install Fireplace " > Each Install/Reloc Vent > * MECHANICAL TOTAL PLDA D s Total Credits. Total Payments. Balance Due. Units Fee/Unit 5 3 50 1 00 4666.14 16 1 1 1 1 2 200 1 1 4 . 27 7.00 15 00 7 7 7 7 00 00 00 00 25 9 00 6 50 4 50 00 350 00 14,520 14 Ext fee Data 500 3 50 1235 00 803 00 27 00 2400 00 4899 00 Y 540 00 Y 4666 14 14570 14 20 00 Y 112 00 15 00 7 00 7 00 7 00 14 00 182 00 10.00 Y 50 00 60 00 15.00 Y 9 00 6 50 18 00 49 . 00 9 00 L CITY OF CARLSBAD 2075 Las Palmas Dr , Carlsbad, CA 92009 (619) 438-1161 DEPT: BUILDING FINAL BUILDING INSPECTION ENGINEERING FIRE PLANNING U/M PLAN CHECKf: CB951376 PERMIT*: CB951376 PROJECT NAME: 3253 SF+701 GAR,PLAN 3,PHASE 3 MARFIORE,TAYLOR WOODROW PA 26-S ADDRESS: 1316 CORVIDAE ST LOT# 45 CONTACT PERSON/PHONE#: MW/930-0296 SEWER DIST: CA WATER DIST: CA WATER DATE: 06/12/96 PERMIT TYPE; SFD —, JUN I 3 1996 INSPECTED /--? ^~p)BY: y//^^ INSPECTED BY: INSPECTED BY: COMMENTS : DATE INSPECTED: &~n-?<!> APPROVED ^ DATE INSPECTED: APPROVED DATE INSPECTED: APPROVED DISAPPROVED DISAPPROVED DISAPPROVED DEPT: BUILDING FINAL BUILDING INSPECTION ENGINEERING FIRE PLANNING U/M PLAN CHECK#: CB951376 PERMIT*: CB951376 WATER DATE: 06/12/96 PERMIT TYPE: SFD PROJECT NAME: 3253 SF+701 GAR, PLAN 3 , PHASE 3 MARFIORE, TAYLOR WOODROW PA 26-S ADDRESS: 1316 CORVIDAE ST LOT# 45 CONTACT PERSON/ PHONE #: MW/930-0296 SEWER DIST: CA WATER DIST: CA INSPECTED BY: INSPECTED BY: INSPECTED BY: fl*aif/ri>yt!?^?^?F^ »,, RECfc.Ivc.iJ ; 1=—— j ; M \ 3 1996 | j \ ' CiTY OF CAKLSBAu ENGiNEERiNG DEIPAPTf" " ; — - /DsST) DATE x 9 , /^Z? INSPECTED: b '/"/'* APPROVED </ DISAPPROVED DATE INSPECTED: APPROVED DISAPPROVED DATE INSPECTED: APPROVED DISAPPROVED COMMENTS : rDEPT: BUILDING FINAL BUILDING INSPECTION ENGINEERING FIRE ^MANNING—; ,U/M PLAN CHECK#: CB951376 PERMITtf: CB951376 PROJECT NAME: 3253 SF+701 GAR,PLAN 3,PHASE 3 MARFIORE,TAYLOR WOODROW PA 26-S ADDRESS: 1316 CORVIDAE ST LQTJ_45_J CONTACT PERSON/PHONE#: MW/930-0296 SEWER DIST: CA WATER DIST: CA WATER DATE: 06/12/96 PERMIT TYPE: SFD INSPECTE f BY: INSPECTED BY: INSPECTED BY: DATE INSPECTED: DATE INSPECTED: DATE INSPECTED: APPROVED APPROVED APPROVED DISAPPROVED DISAPPROVED DISAPPROVED COMMENTS: FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING U/M WATER PLAN CHECK*: CB951376 DATE: 06/12/96 PERMIT*: CB951376 PERMIT TYPE: SFD PROJECT NAME: 3253 SF+701 GAR,PLAN 3,PHASE 3 MARFIORE,TAYLOR WOODROW PA 26-S ADDRESS: 1316 CORVIDAE ST LOT* 45 CONTACT PERSON/PHONE#: MW/930-0296 SEWER DIST: CA WATER DIST: CA INSPECTED _ ^f^^. ^^-S^S" .XI * f S ^ ^r ^f^. DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED COMMENTS: DEPT: BUILDING FINAL BUILDING INSPECTION ENGINEERING W-IREr_i PLANNING U/M PLAN CHECK#: CB951376 PERMIT#: CB951376 PROJECT NAME: 3253 SF+701 GAR,PLAN 3,PHASE 3 MARFIORE,TAYLOR WOODROW PA 26-S WATER DATE: 06/12/96 PERMIT TYPE: SFD ADDRESS: 1316 CORVIDAE ST CONTACT PERSON/ PHONE #: MW/930-0296 SEWER DIST: CA WATER DIST: CA INSPECTED. BY: INSPECTED BY: INSPECTED BY: DATE INSPECTED: DATE INSPECTED: DATE INSPECTED: APPROVED APPROVED APPROVED DISAPPROVED DISAPPROVED COMMENTS: CITY OF CARLSBAD INSPECTION REQUEST PEI?MIT# CB951376 FOR 06/12/96 DESCRIPTION: 3253 SF+701 GAR, PLAN 3 , PHASE 3 MARFIORE, TAYLOR WOODROW PA 26-S TYPE: SFD JOB ADDRESS: 1316 CORVIDAE ST APPLICANT: TAYLOR WOODROW HOMES PHONE: PHONE : PHONE: CONTRACTOR : OWNER: REMARKS: MW/930-0296 SPECIAL INSTRUCT: AM PLS INSPECTOR AREA PD PLANCKtf 94-1167 OCC GRP R3/M1 CONSTR. TYPE VN STE: LOT: 45 714 581-2626 \ INSPECTO TOTAL TIME: CD LVL DESCRIPTION 19 29 39 49 ST Final Structural PL Final Plumbing EL Final Electrical ME Final Mechanical ACT COMMENTS ***** INSPECTION HISTORY ***** DATE DESCRIPTION 060696 Final Combo 052096 Final Electrical 052096 Final Electrical 041096 Interior Lath/Drywall 041096 Exterior Lath/Drywall 041096 Gas/Test/Repairs 040896 Interior Lath/Drywall 040896 Exterior Lath/Drywall 040896 Gas/Test/Repairs 040496 Insulation 040396 Insulation 040396 Rough Combo 040196 Rough Combo 032896 Frame/Steel/Bolting/Welding 032896 Rough Electric 032896 Rough/Topout 030896 Shear Panels/HD's 030696 Shear Panels/HD's 030496 Roof/Reroof 010396 Ftg/Foundation/Piers 122295 Ftg/Foundation/Piers 122095 Underground/Under Floor 122095 Sewer/Water Service ACT NS AP CO AP AP AP NR NR NR NR AP AP AP CO CO AP AP NR AP AP AP AP AP INSP PD DC DC PD PD PD PD PD PD PD PD PD PD PD PD PD PD PD PD PD PY PD PD COMMENTS 3:15 NO ACCESS 9:00 SLAB OK Oate:Report .'" Location:Author:bay: Supt/Foreman Field Supervisor:Geologist:Soil Engineer: Observation/Testing of: h"oo"T' Tech Equant wortcmg:Hours A Today's yardage: Yardage to Date: Surmary of Operations: Ok VC r?e.ft <S' o ~rv> » 5 J L! // /2 • A DAILY FIELD REPORT LEIGHTON AND ASSOCIATES, INC 5910 591 White - File Copy Yellow - Client Copy Pink - Client/Agency Copy Gold - Field Copy Sunnary of Operations: PAi..L»*T^ /- ^" 8} »?g A: ' ^ -a ' v A Z "I - 3 t~ ft ( c A~r TH* -rf/> of a* T1V P-r IV / t -.fc H~T'r*»7'~t~f!-rX *-Qr DAILY FIELD REPORT LEIGHTON AND ASSOCIATES, INC.LJLJ 3910 591 White - File Copy Yellow - Client Copy Pink - Client/Agency Copy Gold - Field Copy DEC-21-1995 38 52W1 9339265 P 31 LEIGHTON AND ASSOCIATES, INC Geoteehmcol awd bwiiwuniinful Eitypiiotring Cowultwits UttMARY Plan File Referenced Geotechmcal Report(s): Date of Repcrt(s):A/ov/ Observation Summary : Initials ;Imtia1s : Initials J*CK .Initials A representative of Lelghton and Associates observed onslte soil conditions. Soil conditions at the site are substantially in conformance with those assumed in tht geotechnfcal report A representative of Leighton and Associates observed and measured footing excavation depth/width. Footing excavations extend to proper depth and bearing strata and are in general conformance with recommendations of the geotechnlcal report. A representative of Leighton and Associates measured footing setback from slope face The setback was 1n general accordance with the recommendations of the geotechmcal report. h/4-uc "7a <?f Notes to Superlntendent/Fpjrgrian 1. Fojit4«9±*S«wtT&"nTThould be cleaned of loose debris and thorough"!:tened just prior to placing concrete. Based on expansion potential of underlying soils, presoaking of soil below slabs may be recommended. Consult the geotechmcal report for presoaking recommendations. We note that presoaking clayey soils nay take an extended period of time and the contractor should schedule accordingly. In the event of a site change subsequent to our footing observation and prior -ta^csncreteplaceoient (i.e., heavy rain, etc.), we should be contacted perform addTTlunul Ute-j&servattons.. ^ Notes to Building Inspector 1. Soil compaction test results, including depth of fill, relative compaction, bearing values, and soil expansion index test results are contained in the As-Graded Geotechmcal Report provided at the completion of grading. \ Representative ofn^eighton and Associates, Inc. 3934 MURPHY CANYON ROA& SUITE B205, SAN DIEGO, CALIFORNIA 92123 Date. (619) 292-8030'(800) 44 7-2626 »X (619) 292-0771 fDTPlL P 31