Loading...
HomeMy WebLinkAbout1319 CORVIDAE ST; ; CB951369; Permit12/15/95 14 Page 1 of Job Address Permit Type Parcel No Valuation B U 49 1 1319 CORVIDAE SINGLE FAMILY 215-690-05-00 232 ,210 ILDING PERMIT Permit No Project No Development No CB951369* A9 502007 ST DWLNG - Suite DETACHED Lot#5175 12/15/93 0001 Construction Occupancy Group R3/M1 Description 2805 SF+ 610 GAP, MARFIORE, TAYLOR Reference*. CT90-36 PLAN 1,PHASE3 WOODROW,PA 26-S Appl/Ownr • TAYLOR WOODROW HOMES 26461 RIDGE ROUTE LACUNA HILLS, CA 92666 Status Applied. Apr/Issue Entered By. ISSUED 11/16/94 12/15/95 RMA 714 581-2626 Plan Check Number > 94-1167 *** Fees Required *** ;. **•* Fees Collected & Credits Fees 13 , 978 .14. Adjustment a . 00 Total Fees 13, 978.14 Fee description i Number of Bedrooms ... . . > Number of Bathrooms ... . . > Building Permit Plan Check Strong Motion Fee :' Enter Number of EDU's - Water Fee > Enter "Y" to Autocalc P.F.F > Enter "Y" to Autocalc T.I F. > Payoff Fee for CFD > * BUILDING TOTAL Enter "Y" for Plumbing Issue Fee > Each Plumbing Fixture or Trap > Each Building Sewer > Each Install/Repair Water Line > Each Water Heater and/or Vent > Gas Piping System > Each Vacuum Breaker > * PLUMBING TOTAL Enter "Y" for Electric Issue Fee > Single Phase Per AMP > * ELECTRICAL TOTAL Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts/Heat Pumps > Each Install Fireplace > Each Install/Reloc Vent > * MECHANICAL TOTAL PLDA D > Total Credits Total Payments: Balance Units 3 2 50 1 . 00 4666 14 16 1 1 1 1 2 200 1 1 4 27 Due: Fee/Unit 7. 15 7 7 7 7 9 6 4 00 00 00 00 00 00 25 00 50 50 350 13,628 00 . 0 0 14 Ext fee 3 2 1105 718 23 2400 4226 540 466b 13678 20 112 15 7 7 7 14 182 10 50 60 15 9 6 18 49 9 00 50 . 00 00 00 . 00 . 00 00 14 . 14 . 00 00 00 00 00 00 00 . 00 00 . 00 00 00 00 50 00 00 00 * * * Data Y Y Y Y Y L CITY OF CARLSBAD 2075 Las Palmas Dr , Carlsbad, CA 92009 DEPT: BUILDING FINAL BUILDING INSPECTION ENGINEERING FIRE PLANNING U/M PLAN CHECK*: CB951369 PERMIT*: CB951369 PROJECT NAME: 2805 SF+ 610 GAR,PLAN 1,PHASES MARFIORE, TAYLOR WOODROW,PA 26-S ADDRESS: 1319 CORVIDAE ST LOT# 5 CONTACT PERSON/PHONE#: MW/KEVIN/930-0296/AM BEST SEWER DIST: CA WATER DIST: CA WATER DATE: 06/05/96 PERMIT TYPE: SFD INSPECT BY: INSPECTED BY: INSPECTED BY: SPECTED: DATE INSPECTED: DATE INSPECTED: APPROVED APPROVED DISAPPROVED DISAPPROVED DISAPPROVED COMMENTS: DEPT: BUILDING FINAL BUILDING INSPECTION ENGINEERING FIRE PLANNING U/M PLAN CHECK#: CB951369 PERMIT#: CB951369 PROJECT NAME: 2805 SF+ 610 GAR,PLAN 1,PHASES MARFIORE, TAYLOR WOODROW,PA 26-S ADDRESS: 1319 CORVIDAE ST LOT# 5 CONTACT PERSON/PHONE#: MW/KEVIN/930-0296/AM BEST SEWER DIST: CA WATER DIST: CA WATER DATE: 06/05/96 PERMIT TYPE: SFD INSPECTED, . BY: r\ A.. INSPECTED BY: INSPECTED BY: DATE INSPECTED: DATE INSPECTED: DATE INSPECTED: . / fa AY APPROVED APPROVED APPROVED n JUN -6 1996 DISAPPROVED DISAPPROVED DISAPPROVED COMMENTS: DEPT: BUILDING FINAL BUILDING INSPECTION ENGINEERING FIRE PLANNING U/M PLAN CHECK#: CB951369 PERMIT*: CB951369 PROJECT NAME: 2805 SF+ 610 GAR,PLAN 1,PHASES MARFIORE, TAYLOR WOODROW,PA 26-S ADDRESS: 1319 CORVIDAE ST LOT# 5 CONTACT PERSON/PHONE#: MW/KEVIN/930-0296/AM BEST SEWER DIST: CA WATER DIST: CA WATER DATE: 06/05/96 'SFD JUN - 4 1996 CITY OF CARLSBAD INSPECTED BY: INSPECTED BY: INSPECTED BY: DATE INSPECTED: DATE INSPECTED: DATE INSPECTED: APPROVED APPROVED APPROVED DISAPPROVED DISAPPROVED DISAPPROVED COMMENTS: FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING U/M CHECK#: CB951369 PERMIT#: CB951369 PROJECT NAME: 2805 SF+ 610 GAR,PLAN 1,PHASE3 MARFIORE, TAYLOR WOODROW,PA 26-S ADDRESS: 1319 CORVIDAE ST LOT# 5 CONTACT PERSON/PHONE#: MW/KEVIN/930-0296/AM BEST SEWER DIST: CA WATER DIST: CA WATER DATE: 06/05/96 PERMIT TYPE: SFD INSPECTEI/7 ) O BY: T~^L^^ INSPECTED BY: INSPECTED BY: COMMENTS : DATE / . Q, INSPECTED: 0" (Or* APPROVED y DATE INSPECTED: APPROVED DATE INSPECTED: APPROVED ' DISAPPROVED DISAPPROVED DISAPPROVED DEPT: BUILDING FINAL BUILDING INSPECTION ENGINEERING FIRE PLANNING U/M PLAN CHECK#: CB951369 PERMIT*: CB951369 PROJECT NAME: 2805 SF+ 610 GAR,PLAN 1,PHASE3 MARFIORE, TAYLOR WOODROW,PA 26-S ADDRESS: 1319 CORVIDAE ST LOT# 5 CONTACT PERSON/PHONE#: MW/KEVIN/930-0296/AM BEST SEWER DIST: CA WATER DIST: CA WATER DATE; 06/05/96 SFD - 4 1996 CITYOFC^RLSE,'-: ENGINEERING DEPART.' INSPECTED £>L*£BY: /^/r^ INSPECTED BY: INSPECTED BY: •3 DATE INSPECTED: b-J~-^ DATE INSPECTED: DATE INSPECTED: V APPROVED V APPROVED APPROVED DISAPPROVED DISAPPROVED DISAPPROVED COMMENTS: CITY OF CARLSBAD INSPECTION REQUEST PERMIT* CB951369 FOR 06/12/96 DESCRIPTION: 2805 SF+ 610 GAR,PLAN 1,PHASES MARFIORE, TAYLOR WOODROW,PA 26-S TYPE: SFD JOB ADDRESS: 1319 CORVIDAE ST APPLICANT: TAYLOR WOODROW HOMES PHONE: PHONE: PHONE: CONTRACTOR: OWNER: INSPECTOR AREA PD PLANCKtf 94-1167 OCC GRP R3/M1 CONSTR. TYPE VN STE: LOT: 5 714 581-2626 REMARKS: MW/930-0296 SPECIAL INSTRUCT: AM INSPECT TOTAL TIME: CD LVL DESCRIPTION 19 29 39 49 ST Final Structural PL Final Plumbing EL Final Electrical ME Final Mechanical ACT COMMENTS u> ***** INSPECTION HISTORY ***** DATE DESCRIPTION 060596 Final Combo 051696 Final Electrical 040296 Interior Lath/Drywall 040296 Exterior Lath/Drywall 040296 Gas/Test/Repairs 032696 Insulation 032196 Rough Combo 030496 Shear Panels/HD's 010296 Ftg/Foundation/Piers 010296 Steel/Bond Beam 122295 Ftg/Foundation/Piers 122095 Ftg/Foundation/Piers 121995 Ftg/Foundation/Piers 121995 Steel/Bond Beam 121995 Underground/Conduit-Wiring 121995 Underground/Under Floor ACT CO AP AP AP AP AP AP AP AP AP AP CO CO CO CO AP INSP PD PD PD PD PD PY PD PD PD PD PD PD PD PD PD PD COMMENTS TSPB SLAB Observation/Testing of: Summary of Operations: ok VC, ~TVtj |fr>J15 . A •.$&£$: V^•KI^'S"™--' Page - of - DAILY FIELD REPORT LEIGHTON AND ASSOCIATES, INC. 3910 591 White - File Copy Yellow • Client Copy Pink • Client/Agency Copy Gold - Field Copy Summary of Operations: A Q) v A / / ' <- 3 ft t c )(. V l* Pr»«X>/*n7y ''-' -5 l rX 77 DAILY FIELD REPORT LEIGHTON AND ASSOCIATES, INC. 3910 591 White - File Copy Yellow • Client Copy Pink - Client/Agency Copy Gold - Field Copy DEC-21-1995 38 52PM CPRL3BPD RftSICH TO 9309265 = 31 LEIGHTON AMD ASSOCIATES, INC and Environnvulul Cowwtonts Project No: ^ 10-5^2.-001 Referenced Geotecnmcal Report(s): Date of Report(s): Observation Summary _:ln1t1als A representative of Leighton and Associates observed onslte soil conditions. Soil conditions at the site are substantially in conformance with those assumed in the geotechnical report ilmtials A representative of Leighton and Associates observed and measured footing excavation depth/wfdth. Footing excavations extend to proper depth and bearing strata and are in general conformance with recommendations of the geotechnical report. :In1t1als A representative of Leighton and Associates measured footing rOate setback from slope face. The setback was fn general accordance with the recommendations of the geotechnical report. J-Q< Initials Caif.fr Notes to Superlntendent/Forenan 1. FojI^jm "ir*uiV» tTgnsshou 1 d be cleaned of loose debris and thorough"] Eened just prior to placing concrete. Based on expansion potential of underlying soils, presoakfng of soil below slabs may be recommended. Consult the geotechnical report for presoaking recommendations. We note that presoaking clayey soils may take an extended period of time and the contractor should schedule accordingly. In the event of a site change subsequent to our footing observation and prior placement (i.e., heavy rain, etc.), we should be contacted perform addTTlunal UJe_£bservationy. Notes to Building Inspector 1. Soil compaction test results, including depth of fill, relative compaction, bearing values, and soil expansion index test results are contained in the As-Graded Geotechmcal Report provided at the completion of grading. \ Representative ofnTelghton and Associates. Inc. 3934 MURPHY CANYON RQA& SUITE 8205, SAN OIWQ CALIFORNIA 92123 Date; (619) 292-8030 • '800) 447-2626 FAX (619) 292-0771 TDT3L => 31