Loading...
HomeMy WebLinkAbout1325 CORVIDAE ST; ; CB131377; Permit08-27-2013 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Cogeneration Permit Permit No CBI31377 Building Inspection Request Line (760) 602-2725 1325 CORVIDAE ST CBAD COGEN Sub Type PHOTO 2156900600 Lot# 0 $13,600 00 Constuction Type NEW Reference # STANFORD 34 PANEL ROOF MOUNT PV SYSTEM Status ISSUED Applied 06/04/2013 Entered By JMA Plan Approved 08/27/2013 Issued 08/27/2013 Inspect Area Plan Check* Applicant JK SOLAR Owner STANFORD DREW A&JEAN C 13415 PROSPECTOR RD VICTORVILLE CA 92392 760-617-6856 1325 CORVIDAE ST CARLSBAD CA 92011 Building Permit $166 07 PLUMBING TOTAL $0 00 Add'l Building Permit Fee $0 00 ELECTRICAL TOTAL $0 00 Plan Check $11625 MECHANICAL TOTAL $0 00 Add'l Plan Check Fee $0 00 Additional Fees $0 00 Plan Check Discount Strong Motion Fee Green BIdg Stands (SB1473) Fee $0 00 $1 36 $1 00 TOTAL PERMIT FEES $284 68 Total Fees $284 68 Total Payments To Date $284 68 Balance Due $0 00 Inspector FINAL ARP Date PPR OVAL 13 Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively refen'ed to as "fees/exactions" You have 90 days from the date this perniit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follov;/ that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously othenivise expired THEFOLLOWINGAPPROVALSREQUIREDPRIORTOPERMITISSUANCE DPLANNING DENGINEERING nBUILDING DFIRE •HEALTH • HAZMAT/APCD r^ ^'ciTY OF CARLSBAD Building Permit Application 1635 Faraday Ave , Carlsbad, OA 92008 Ph 760-602-2719 Fax 760-602-8558 email buldling@carlsbadca gov www carlsbadca gov Plan Check No. Cg) | 3 ' (3>17 Est. Value ^ (3 ,(o00. Plan Ck. Deposit Date SWPP JOB ADDRESS Ul^Co^eviM^ SUITE#/SPACE#/UNIT# CT/PROJECT # PHASE # # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR TYPE OCC GROUP DESCRIPTION OF WORK Incfude Square Feet of Affected Area(s) 3^ /7flp^/6e5 EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YESD # NO • AIR CONDITIONING YES • NOD FIRE SPRINKLERS YES D NOD APPLICANT NAME (Primary Contact) APPLICANT NAME (Secondary Contact) ADDRESS ADDRESS CITY STATE ^ PHONE . , FAX ^ _ EMAIL , , ^ 1 V CITY STATE ZIP PHONE FAX 0 cArL f YAmO' con EMAIL PROPERTY OWNER NAIVIE CONTRACTOR BUS NAIVIE ADDRESS /.ITS' rOfC W D/f^ ^< ADORESS STATE Oh TZOll CITY STATE ZIP PHONE FAX PHONE FAX EMAIL EMAIL ARCH/DESIGNER NAME & ADDRESS CITY BUS LIC# (Sec 7031 5 Business and Professions Code Any City or County wjhicti requires a permit to construct alter, improve, demolish or repair any structure, prior to its issuance, also requires ttie applicant for sucti permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License LavK (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)) Workers' Compensation Declaration / hereby affimi under penalty ofpeijury one ofthe following declarations O I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code, for the perfonnance of the work for which this permit is issued 1 have and will maintain workers'comp|nsation, as required by Section 3700 of the Labor Code, for the perfonnance of the work fonivhich this pemit is issued My workers' compensajioif injiyance earner and policy number are Insurance Co ^TTu^ F^I^O Policy No jffZMVf fl Expiration Date lljyiy This section need not be completed if the permit is for one hundred dollars ($100) or less O Certificate of Exemption I certify that in the performance of the work for which this pemit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to cnminal penalties and civil fines up to one hundred Uiousand dollars (&100,000), in addition to the cost of compensationVlamages^as^rovided for in Section 3706 ofthe Labor code, interest and attomey's fees vfiS* CONTRACTOR SIGNATURE IS • AGENT DATE I hereby affinn that I am exempt from Contractor's Ucense Law for the following reason • I, as owner of the pnjperty or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) O I, as owner of the pnjperty, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) • I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and matenals for construction of the proposed property improvement • Yes O No 2 I (have / have not) signed an application for a building pemiit for the proposed work 3 I have contracted with the following person (fim) to provide the proposed construction (include name address / phone / contractors' license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supen/ise and provide the ma)or work (include name / address / phone / contractors' license number) 5 I will provide some of the vrork, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work) ygfpROPERTY OWNER SIGNATURE •AGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous matenals registration form or nsk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account AcP • Yes • No Is the applicant or future building occupant required to obtain a permit from the air pollution control distnct or air quality management distncP • Yes O No Is the facility to be constmcted within 1,000 feet of the outer boundary of a school site'' O Yes • No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPUCANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affinn that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name Lender's Address I certiV ttiat I have lead ttie application and state that the above infomiation is conect and ttiat the intbimaton on ttie plans is accurate 1 agree to comply witti all Cify oidinances and State laws relating to building constmction I hereby aulhonze lepresentative ofthe City of Carlsbad to enter upon the above mentioned property for inspecton purposes I ALSO AGFEE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF GARLSBAD AGAINST ALL UABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA AjiOSHApennit IS requined for excavations over 5'0' deep and demolition or constaiction of stmctures over 3 stones in height EXPIRATION Every permit Esue<H!y the Building Official under the provisions of this Code shall expire by limitation and become null and vod if the building or wo* authonzed by such permit is not commenced within 180 days fom the date of such perf|mor if the bujdmg or viork authonzed by such pemit is suspended or abandoned at any time after the work is commenced for a penod of 180 days (Section 106 4 4 Unifom Building Code) ^APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CATE OF OCCUPANCY { Comi (Jccts Only) Fax (760) 602-8560, Email www buildinq(a)carlsbadca qov or Mail the completed fom to City of Carisbad, Building Division 1635 Faraday Avenue, Cartsbad, California 92008 C0#- (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANTS BUS LIC No DELIVERY OPTIONS • PICKUP • CONTACT (Listed above) • OCCUPANT (Listed above) • CONTRACTOR (On Pg 1) • MAIL TO • CONTACT (Listed above) • OCCUPANT (Listed above) • CONTRACTOR (On Pg 1) • MAIL / FAX TO OTHER • ASSOCIATED CB# • NO CHANGE IN USE/NO CONSTRUCTION • CHANGE OF USE / NO CONSTRUCTION • ASSOCIATED CB# • NO CHANGE IN USE/NO CONSTRUCTION • CHANGE OF USE / NO CONSTRUCTION -gf APPLICANT'S SIGNATURE DATE Inspection List Permit# CB131377 Type COGEN PHOTO Date Inspection Item 08/28/2013 35 Photo Voltaic (PV) 08/28/2013 35 Photo Voltaic (PV) 08/28/2013 39 Final Electncal 08/28/2013 39 Final Electrical Inspector Act Rl MC AP Rl MC Fl STANFORD 34 PANEL ROOF MOUNT PV SYSTEM Comments PER PLAN CALLED IN TO MONICA Friday, August 30, 2013 Page 1 of 1 EsGil Corporation In (Partnership with (government for (BuMing Safety DATE 08/21/13 JURISDICTION Carlsbad PLAN CHECK NO 13-1377 SET III PROJECTADDRESS 1325 Corvidae St. PROJECT NAME Stanford 34-215 Watt micro inverters Solar Photovoltaic System 2@17 XI The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's building codes I I The plans transmitted herewith will substantially comply with the junsdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck I I The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person I I The applicant's copy of the check list has been sent to IXI Esgil Corporation staff did not advise the applicant that the plan check has been completed I I Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Jeremy Kanning Telephone # 760-617-6856 Date contacted (by ) Fax # Mail Telephone Fax In Person E-mail jksolar(gyahoo com • REMARKS By John Le Vey Enclosures EsGil Corporation • GA • EJ • PC 08/15/13 9320 Chesapeake Dnve, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 A I EsGil Corporation In (PartnersHip witH government for (BuiCrftng Safety DATE 07/08/13 JURISDICTION Carlsbad PLAN CHECK NO 13-1377 SET II PROJECT ADDRESS 1325 Corvidae St. PROJECT NAME Stanford 34-215 Watt micro inverters Solar Photovoltaic System 2@17 I I The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's building codes I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff r~| The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck IXI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck r~| The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person I I The applicant's copy of the check list has been sent to r~| Esgil Corporation staff did not advise the applicant that the plan check has been completed ^ Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Jeremy Kanning Telephone # 760-617-6856 Date contacted '^('^ ()3 (by ) Fax # 6 Mail ^ Telephone Fax In Person E-mail jksolar(gyahoo com • REMARKS By John Le Vey Enclosures EsGil Corporation • GA • EJ • PC 07/02/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 13-1377 07/08/13 GENERAL PLAN CORRECTION LIST JURISDICTION Carlsbad PLAN CHECK NO 13-1377 PROJECT ADDRESS 1325 Corvidae St. DATE PLAN RECEIVED BY ESGIL CORPORATION 07/02/13 DATE REVIEW COMPLETED 07/08/13 REVIEWED BY John Le Vey FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electncal Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review IS based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineenng Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations The approval of the plans does not permit the violation of any state, county or city law • Please make all corrections and submit two new complete sets of pnnts to ESGIL CORPORATION • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please bnefly describe them and where they are located on the plans Have changes been made not resulting from this lisf? • Yes • No Carlsbad 13-1377 07/08/13 ELECTRICAL and ENERGY COIVIMENTS PLAN REVIEWER: John Le Vey ELECTRICAL (2010 CALIFORNIA ELECTRICAL CODE) 1 Please provide the conduit lengths on the roof, or the single line sheet E-1, to justify the voltage drop per en phase which only allows a 2 percent drop There is no scale on the sheets, otherwise I could scale the lengths This is and will be required for all en phase systems Also to assure the system will comply with the voltage drop see the en phase technical report Second plan check it appears the lengths will exceed the maximum voltage rise FYI the voltage drop in counted from the main service panel to the sub panel as per the en phase report V rise from the micro inverters to the AlC junction box. V rise from the AJC junction box to the sub panel. V rise from the micro inverter sub panel to the main service. This information is on page 10 ofthe en phase techincial report 2 Additional the wp j boxes on the roof sheet must be A/C disconnects unless the inverters will be within site of the sub panel on the roof change the roof plan and the single line to show , as required per the CEC690 14(D)(2) Within site ofthe inverter which IS behind the module, again unless visible from the sub panel, this may not be required Note: If you have any questions regarding this Electncal and Energy plan review list please contact John Le Vey at (858) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans EsGil Corporation In (PartnersHip with government for (ButCifing Safety DATE 06/11/13 O^PtlCANT d^URIS^ JURISDICTION Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO 13-1377 SET I PROJECT ADDRESS 1325 Corvidae St. PROJECT NAME Stanford 34-215 Watt micro inverters Solar Photovoltaic System 2@17 r~] The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's building codes r~] The plans transmitted herewith will substantially comply with the junsdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff r~| The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck r~] The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person I I The applicant's copy of the check list has been sent to I I Esgil Corporation staff did not advise the applicant that the plan check has been completed IXI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Jeremy Kanning (^.t^) Telephone # 760-617-6856 Date contacted li>f> 11|> (by \<^) Fax # ^MailTelephone/^ Fax In Person E-mail jksolar(gyahoo com • REMARKS By John Le Vey Enclosures EsGil Corporation • GA • EJ • PC 06/04/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858)560-1468 • Fax (858) 560-1576 Carlsbad 13-1377 06/11/13 GENERAL PLAN CORRECTION LIST JURISDICTION Carlsbad PLAN CHECK NO 13-1377 PROJECT ADDRESS 1325 Corvidae St. DATE PLAN RECEIVED BY ESGIL CORPORATION 06/04/13 DATE REVIEW COMPLETED 06/11/13 REVIEWED BY John Le Vey FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electncal Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review IS based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineenng Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations The approval of the plans does not permit the violation of any state, county or city law • Please make all corrections and submit two new complete sets of pnnts to ESGIL CORPORATION • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please bnefly descnbe them and where they are located on the plans Have changes been made not resulting from this list? • Yes • No Carlsbad 13-1377 06/11/13 ELECTRICAL and ENERGY COMMENTS PLAN REVIEWER: John Le Vey ELECTRICAL (2010 CALIFORNIA ELECTRICAL CODE) 1 Please provide the conduit lengths on the roof, or the single line sheet E-1, to justify the voltage drop per en phase which only allows a 2 percent drop There is no scale on the sheets, otherwise I could scale the lengths This is and will be required for all en phase systems Also to assure the system will comply with the voltage drop see the enphase technical report Note: If you have any questions regarding this Electncal and Energy plan review list please contact John Le Vey at (858) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans Carlsbad 13-1377 06/11/13 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO 13-1377 PREPARED BY John Le Vey DATE 06/11/13 BUILDING ADDRESS 1325 Corvidae St. BUILDING OCCUPANCY TYPE OF CONSTRUCTION BUILDING PORTION AREA (Sq Ft) Valuation Multiplier Reg Mod VALUE ($) PV system Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance BIdg Permit Fee by Ordinance Plan Ctieck Fee by Ordinance Type of Review I I Repetitive Fee ^ Repeats • Complete Review • Other 0—Hourly EsGil Fee • Structural Only $86 00 Hr. @ $107.50 $86 00 Based on hourly rate ^ CITY O c CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www carlsbadca aov DATE: 6-5-13 PROJECT NAME: PROJECTID: PLAN CHECK NO: CB 13-1377 SET#: 1 ADDRESS: 1325 Corvidae APN: This plan check review Is complete and has been APPROVED by the Planning Division. By: Chris Sexton A Final Inspection by the Planning Division is required • Yes ^ No You may also have corrections from one or more ofthe divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. • This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: jksolar@yahoo.com For questions or clarifications on the attached checklist please contact the followmg reviewer as marked PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 X Chris Sexton 760-602-4624 Chris Sexton@carlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov Greg Ryan 760-602-4663 Gregory Rvan@carlsbadca gov 1 ] Gma Ruiz 760-602-4675 Gina Ruiz@carlsbadca gov 1 Linda Ontiveros 760-602-2773 Linda Ontiveros@carlsbadca gov Cindy Wong 760-602-4662 Cvnthia Wong@carlsbadca gov • • 1 1 Dommic Fieri 760-602-4664 Dominic Fieri@carlsbadca gov Remarks: