Loading...
HomeMy WebLinkAbout1330 CYNTHIA LN; ; CB031766; Permit05-04-2009 Job Address Permit Type Parcel No Valuation Occupancy Group # Dwelling Units Bedrooms Project Title City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No CB031766 Building Inspection Request Line (760) 602-2725 1330 CYNTHIA LNCBAD RESDNTL 1562316200 $147,39400 1 3 Sub Type SFD Lot# 0 Construction Type VN Reference # Structure Type SFD Bathrooms 2 5 GILBERT RES-1558 SF.484 SF GAR APPLICANT WITHDREW 4/9/04 TOOK PLANS Status Applied Entered By Plan Approved Issued Inspect Area Ong PC# Plan Check* WITHDRAW 06/27/2003 RMA Applicant RICHARD GILBERT SR 2810ELMWOODST 92008 760729-1280 Owner BOYLAN PETER J&CYNTHIA H 1334CYNTHIALN CARLSBAD CA 92008 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee HMP Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee Green Bldg Stands (SB1473) Fee $694 40 Meter Size $0 00 Add'l Reel Water Con Fee $451 36 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $1474 PFF (3105540) $0 00 PFF (4305540) $0 00 License Tax (3104193) $0 00 License Tax (4304193) $000 Traffic Impact Fee (3105541) $000 Traffic Impact Fee (4305541) $0 00 Sidewalk Fee $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Housing Impact Fee ?9 Housing InLieu Fee $2,400 00 Housing Credit Fee D5/8 Master Drainage Fee $599 00 Sewer Fee $0 00 Additional Fees 7? TOTAL PERMIT FEES $000 $14000 $2,004 00 $000 $000 $000 $000 $000 $460 60 $51940 $000 $000 $000 $000 $000 $4,51500 $000 $000 $927 00 $000 $12,72550 Total Fees $12,725 50 Total Payments To Date $451 36 Balance Due $12,27414 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO Cft& 1*J7EST VAL Plan Ck Deposit. Validated B> Date i ByL~7T^ 1ft PROJECT INFORMATION J\:: CONTACT PERSON (indifferent from applcan Name Address City I0!!11** 'APPLICANT jf QjContractor D Agent for Contractor D'Owner^nM Agent "for Owner State/Zip Telephone tt Fax Name 4 PROPERTyjOWNER Name 1" CONT RACTOrV- COMPANY NAME (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9, commending with Section 7000 of Division 3 of trie Business and Professions Code) or that he is exempt therefrom, and the basrs for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) Name State License Address License Class City State/Zip City Business License tt Telephone # Designer Name Address City State/Zip Telephone State License # L6. WORKERS'COMPENSATION '" W' •'• >;:bi •..,,-,::=•==—.,• • .,.. ..K, ^ Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued f~l I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are Insurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) Q CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE DATE 7 OWNER-BUILDER DECLARATION -B;V . ...:..:- • , ^ ... ' '*•" - -i*- tMh ' I hereby affirm that I am exempt from the Contractor's License Law for the following reason Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) I, as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The ontractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) (~1 I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement l~l YES 2 I (have / have not) signed an application for a building permit for the proposed work 3 I havacorvtiactad with>lhejollowirig person.(firm)ftrppromp'e the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type /of work) /) PROPERTY OWNER SIGNATURE COMPLETE THISi''S'ECTION:FORllKW^£51DCW7Z<U BUJLDTmTPERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' Q YES O NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 8. .„, CONSTRUCTION LENDING AGENCY p: ' ?? ~ I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code) LENDER S NAME LENDER'S ADDRESS 9 APPLICANT CERtlFICATION '-.^m^ "9" "" ::' :i.i-:.. "" ,;:it- "!" ^ I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stones in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is nojipjnrrtenced withnvlSO days from tjfje date of such permit or if the building or work authorized by such permit is suspended or abandoned jat any time after the work is «JAPPLICANT'S SIGNATURE DATE WHITE File YELLOW Applicant PINK Finance City of Carlsbad Building Department 03/23/2004 RICHARD GILBERT SR 2810ELMWOOD92008 Re Application Date 06/27/2003 0 00 00 Plan Check # CB031766 Address 1330 CYNTHIA LN Expiration Date 06/26/2004 0 00 00 Pe-mitType RESDNTL Description GILBERT RES-1558 SF.484 SF GAR 231 SF PATIO You applied to have your plans checked on the date noted above To date, the related building permit has not been obtained The original plan review application will expire as no building permit has been issued Plans submitted and not retrieved from the building department prior to the plan check expiration date noted above will be destroyed The provisions of sections 304 (d) of the Uniform Building Code state "Section 304 9d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee " In order to provide better service, please indicate your nandiing choice for the plans originally submitted and return this letter to the Building Department Project Abandoned - I will pick up plans within 10 days Project Abandoned - Plans may be destroyed If you have any questions, please contact the Building Department at (760) 602-2702 Robin Nuschy Building Department 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 6O2-2700 • FAX (76O) 602-8560 EsGil Corporation In Partnership with government f or (Bmbfing Safety DATE March 3, 2O04 __ B_APPJJCANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 03-1766 SET II PROJECT ADDRESS 1330 Cynthia Ln. PROJECT NAME SFD for Richard Gilbert The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff [~1 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person [X] The applicant's copy of the check list has been sent to Richard Gilbert Jr 3205 Via Pescado, Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed [X] Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Richard Gilbert Jr Telephone # (760) 434-5459 Date contacted *l^°u (by ^ ) Fax # Mail tX Telephone >/ Fax In Person/W^VREMARKS By Sergio Azuela Enclosures Esgil Corporation D GA D MB D EJ D PC 2/26 tmsmUdot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 •* Fax (858) 560-1576 Carlsbad O3-1766 March 3, 2OO4 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PROJECT ADDRESS 1330 Cynthia Ln. DATE PLAN RECEIVED BY ESGIL CORPORATION 2/26 REVIEWED BY Sergio Azuela PLAN CHECK NO O3-1766 SET II DATE RECHECK COMPLETED March 3, 2004 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans B The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items C Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo Carlsbad O3-1766 March 3, 2OO4 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 6 On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below Section 106 3 2 REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec 1701 of the Uniform Building Code ITEM REQUIRED? REMARKS SOILS COMPLIANCE PRIOR TO YES SOILS REPORT FOUNDATION INSPECTION STRUCTURAL CONCRETE YES F'c = 4,500 PSI OVER 2500 PSI • No response was provided for this correction. Original correction is still applicable. 7 Applicant shall provide a "Special Inspection Program" to the Building Official The Building Department will resolve this correction. FIRE PROTECTION 8 A smoke detector is missing in the first floor SEE NEXT PAGE FOR ADDITIONAL REMAINING CORRECTIONS. Carlsbad O3-1766 March 3, 2O04 9 Sleeping rooms shall have a window or exterior door for emergency escape Sill height shall not exceed 44" above the floor Windows must have an openable area of at least 5 7 square feet with the minimum openable width 20" and the minimum openable height 24" The emergency door or window shall be openable from the inside to provide a full, clear opening without the use of separate tools Section 3104 • Clearly show on plans that the following windows will provide the required minimum openable height of 24": 4040 and 2640 DBL Hang @ Bedrooms 2 and 3. 14 Glazing in the following locations should be of safety glazing material in accordance with Section 2406 4 (see exceptions) a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors b) Doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers and in any portion of a building wall enclosing these compartments where the bottom exposed edge of the glazing is less than 60 inches above a standing surface and dram inlet c) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface • Clearly show on plans the particular doors and windows that shall be provided with safety glass (general notes will not be adequate to resolve this correction). 15 Guardrails (Section 509 1) a) Shall have a height of 36" b) Shall be detailed showing adequacy of connections to resist the horizontal force prescribed in Table 16-B c) Openings between railings shall be less than 4" The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6" • Show it on plans for the stairway well at the second floor. 17 Handrails (Section 1003336) a) The handgrip portion of all handrails shall be not less than 1-1/4 inches nor more than 2 inches in cross-sectional dimension Handrails projecting from walls shall have at least 1-1/2 inches between the wall and the handrail b) Ends of handrails shall be returned or shall have rounded terminations or bends • No response was provided for this correction. Original correction is still applicable. Carlsbad O3-1766 March 3, 2OO4 18 Specify on the plans the following information for the roof materials, per Section 106 3 3 a) Manufacturer's name b) Product name/number c) ICBO approval number, or equal • No response was provided for this correction. Original correction is still applicable. 23 Show garage framing sections, size of header over garage opening (2- 2X1 0's spandmg 16', shall be checked for deformation), lateral cross bracing at plate line, method bracing garage front and holddowns if required Chapter 16 NOTE Maximum shear panel height-to-width ratio is 31/4 -to-1 for plywood Table 23-ll-G In Seismic Zone 4, this 3>2-to-1 ratio is only permitted in one-story garages with a wall height not exceeding 10 feet • No response was provided for this correction. Original correction is still applicable. 25 The foundation plan does not comply with the soils report recommendations for this project Please review the report and modify design, notes and details as required to show compliance c) Slab on grade underlayment 27 Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (required by the soil report - page 9) • The required letter was not provided. Original correction is still applicable. 30 Show distance from foundation to edge of cut or fill slopes ("distance-to- daylight") and show slope and heights of cuts and fills Chapter 18 • No response was provided for this correction. Original correction is still applicable. 31 Note on plans that surface water will dram away from building and show drainage pattern Section 1804 7 • No response was provided for this correction. Original correction is still applicable. SEE NEXT PAGE FOR ADDITIONAL REMAINING CORRECTIONS. Carlsbad O3-1766 March 3, 2004 32 Show foundation bolt size and spacing Foundation bolt size and spacing for shear walls must be clearly shown on the foundation plan Section 18066 • Shear wall schedule was not provided. Also please show all shear walls at the Foundation Plan 33 The following anchor bolt requirements shall apply in Seismic Zones 3 and 4, per Section 18066 1 a) The minimum nominal anchor bolt diameter shall be 5/8-inch (for Seismic Zone 4 only) Note This will require a minimum distance from the ends of sill plates to be 4-3/8" (and a maximum of 12") b) Plate washers (minimum size of 2" x 2" x 3/16") shall be used on each anchor bolt • No response was provided for this correction. Original correction is still applicable. 34 Specify size, I C B O number and manufacturer of power driven pins, expansion anchors or epoxy anchors Show edge and end distances and spacing Section 106 3 3 • No response was provided for this correction. Original correction is still applicable 47 Detail shear transfer connections, including roof and floor diaphragms, to shear walls Section 2315 • Shear wall schedule was not provided. Also please include all shear walls at the foundation and framing plans. 48 Specify nail size and spacing for all shear walls Indicate required blocking Maintain maximum diaphragm dimension ratios Sections 2315 and 2513 • Shear wall schedule was not provided. Also please include all shear walls at the foundation and framing plans 49 The minimum length of all shear walls shall be specified at each location on the structural plans • Please include all shear walls and their lengths at the foundation and framing plans. 50 In Seismic Zone 4, aspect ratios are limited to 2 1 for wood shear panels Table 23-ll-G a) This correction will be rechecked after the information required under correction # 49 above has been clearly shown on plans SEE NEXT PAGE FOR ADDITIONAL REMAINING CORRECTIONS. Carlsbad O3-1766 March 3, 20O4 52 Show the type and size (BTU's) of all heating and cooling appliances or systems • No response was provided for this correction. Original correction is still applicable. 53 Show source of combustion air to furnace, per Chapter 7, UMC Specify the location and sizes of both of the combustion air openings • No response was provided for this correction. Original correction is still applicable. 54 Specify on the plans the following information for the fireplace(s), per Section 106 33 a) Manufacturer's name b) Model name/number c) ICBO approval number, or equal d) Show height of chimney above roof per ICBO approval or UBC Table 31-B e) Note on the plans that approved spark arresters shall be installed on all chimneys UBC, Section 3102 3 8 • No response was provided for this correction. Original correction is still applicable. 56 Note on the plans that receptacle outlet locations will comply with NEC Art 210-52(a) • No response was provided for this correction. Original correction is still applicable. 62 Show water heater size (1st hour rating), type, and location on plans UPC, Section 501 0 • No response was provided for this correction. Original correction is still applicable. 63 Note on the plans that "Combustion air for fuel burning water heaters will be provided in accordance with UPC Section 507 and Table 5-1" • No response was provided for this correction. Original correction is still applicable. 64 Show T and P valve on water heater and show route of discharge line to exterior UPC, Section 608 5 • No response was provided for this correction. Original correction is still applicable. SEE NEXT PAGE FOR ADDITIONAL REMAINING CORRECTIONS. Carlsbad 03-1766 March 3, 2004 67 The window schedule shall clearly describe the required U-factor and solar heat gam coefficient (SHGC) values and demonstrate compliance with the Title 24 energy calculations • No response was provided for this correction. Original correction is still applicable. 68 The regulations require a properly completed and properly signed Form CF-1R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design • No response was provided for this correction. Original correction is still applicable. 69 All sheets of the latest CF-1 R form must be imprinted onto the plans (sheets 1 of 3, 2 of 3 and 3 of 3 must be included) • No response was provided for this correction. Original correction is still applicable. 72 Show the make, model, type and efficiency of the space heating (or cooling) system • No response was provided for this correction. Original correction is still applicable. 73 Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen(s) and bathrooms (containing a tub or shower) • No response was provided for this correction. Original correction is still applicable. 74 Note on the plans "The manufactured windows shall have a label attached certified by the National Fenestration Rating Council (NFRC) and showing compliance with the energy calculations " • No response was provided for this correction Original correction is still applicable. 75 Special inspection is required, the designer shall complete the attached Special Inspection Notice • No response was provided for this correction. Original correction is still applicable. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation Thank you EsGii Corporation In Partnership with government for (RwCtfing Safety DATE July 10, 2003 a AEELJCANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 03-1766 SET I PROJECT ADDRESS 133O Cynthia Ln. PROJECT NAME SFD for Richard Gilbert The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck [X] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Richard Gilbert Jr 3205 Via Pescado, Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Richard Gilbert Jr (/-/M) Telephone # (760) 434-5459 Date contacted ? 111 /o3(by ^ ) Fax # Mail .^-Telephone ~^ Fax In Person REMARKS By Sergio Azuela Enclosures Esgil Corporation D GA D MB D EJ Q PC 6/SO trnsmtldot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 Carlsbad O3-1766 July 10, 2003 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO O3-1766 JURISDICTION Carlsbad PROJECT ADDRESS 1330 Cynthia Ln. FLOOR AREA Dwelling 1,558 SF STORIES 2 + Basement Basement 781 SF, Patio 231 SF Detached Garage 484 SF HEIGHT REMARKS DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION 6/27 ESGIL CORPORATION 6/30 DATE INITIAL PLAN REVIEW PLAN REVIEWER Sergio Azuela COMPLETED July 10, 2003 FOREWORD (PLEASE READ)- This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes 1997 UBC, 2000 UPC, 2000 UMC and 1999 NEC (all effective 11/1/02) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997" Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad O3-1766 July 1O, 2003 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 All sheets of plans must be signed by the person responsible for their preparation (California Business and Professions Code) 3 Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction Specify expiration date of license (California Business and Professions Code) 4 Specify on the Title Sheet of the plans the gross floor area of each element of this project, including dwelling, garage, carport, patio, deck and balcony Section 10633 5 Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC 6 On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below Section 106 3 2 • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec 1701 of the Uniform Building Code ITEM REQUIRED? REMARKS • SOILS COMPLIANCE PRIOR TO YES SOILS REPORT FOUNDATION INSPECTION • STRUCTURAL CONCRETE YES F'c = 4,500 PSI OVER 2500 PSI • STRUCTURAL MASONRY Carlsbad 03-1766 July 10, 2003 7 When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review Section 106 3 5 Please complete the attached form • FIRE PROTECTION 8 Show locations of permanently wired smoke detectors with battery backup a) Inside each bedroom b) In the basement, if part of the dwelling unit NOTE Detectors shall sound an alarm audible in all sleeping areas of the unit Section 3109 1 . GENERAL RESIDENTIAL REQUIREMENTS 9 Sleeping rooms shall have a window or exterior door for emergency escape Sill height shall not exceed 44" above the floor Windows must have an openable area of at least 5 7 square feet with the minimum openable width 20" and the minimum openable height 24" The emergency door or window shall be openable from the inside to provide a full, clear opening without the use of separate tools Section 310 4 10 Basements in dwelling units shall comply with the above (even if not designated as sleeping rooms) Section 310 4 11 Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1203 3 a) Basement 12 Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet In bathrooms and water closet compartments, 1/20 of area is required and minimum is 1 5 sq ft Section 1203 3 a) Basement 13 Dimension on the plans 30" clear width for water closet compartments and 24" clearance in front of water closet Section 2904 14 Glazing in the following locations should be of safety glazing material in accordance with Section 2406 4 (see exceptions) a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors b) Doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers and in any portion of a building wall enclosing these compartments where the bottom exposed edge of the glazing is less than 60 inches above a standing surface and dram inlet c) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface Carlsbad O3-1766 July 1O, 2O03 • EXITS, STAIRWAYS, AND RAILINGS 15 Guardrails (Section 509 1) a) Shall have a height of 36" b) Shall be detailed showing adequacy of connections to resist the horizontal force prescribed in Table 16-B c) Openings between railings shall be less than 4" The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6" 16 Provide stairway and landing details Sections 1003 3 3 a) Maximum rise is 7" and minimum run is 11" When the stairs serves less than 10 occupants, or serves an unoccupied roof, rise may bo 8" maximum and run 9" minimum b) Minimum headroom is 6'-8" 17 Handrails (Section 1003 3 3 6) a) The handgrip portion of all handrails shall be not less than 1-1/4 inches nor more than 2 inches in cross-sectional dimension Handrails projecting from walls shall have at least 1-1/2 inches between the wall and the handrail b) Ends of handrails shall be returned or shall have rounded terminations or bends • ROOFING 18 Specify on the plans the following information for the roof materials, per Section 10633 a) Manufacturer's name b) Product name/number c) ICBO approval number, or equal 19 Per local ordinance, a Class A roof is required 20 Show the required ventilation for attics (or enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters) The minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents) Show area required and area provided Section 1505 3 21 Where eave vents are installed, insulation shall not block the free flow of air A minimum of 1" of air space shall be provided between the insulation and the roof sheathing To accommodate the thickness of insulation plus the required 1" clearance, member sizes may have to be increased for rafter-ceiling joists Section 1505 3 22 Note on the plans "Attic ventilation openings shall be covered with corrosion-resistant metal mesh with mesh openings of 1/4-inch in dimension " Section 15053 Carlsbad 03-1766 July 1O, 2O03 • GARAGE AND CARPORTS 23 Show garage framing sections, size of header over garage opening (2-2X10's spandmg 16', shall be checked for deformation), lateral cross bracing at plate line, method bracing garage front and holddowns if required Chapter 16 NOTE Maximum shear panel height-to-width ratio is 3Y2 -to-1 for plywood Table 23-ll-G In Seismic Zone 4, this 31/2-to-1 ratio is only permitted in one-story garages with a wall height not exceeding 10 feet • CONCRETE AND MASONRY 24 Show height and construction details of all masonry or concrete walls Chapters 21 and 19 • FOUNDATION REQUIREMENTS 25 The foundation plan does not comply with the soils report recommendations for this project Please review the report and modify design, notes and details as required to show compliance a) Foundation depth b) Foundation reinforcement c) Slab on grade reinforcement and underlayment 26 The soils engineer recommended that he/she review the foundation excavations Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that a) The building pad was prepared in accordance with the soils report, b) The utility trenches have been properly backfilled and compacted, and c) The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report" d) Concrete that is in contact with the natural ground shall have the following parameters i) Cement type V n) F'c = 4,500 psi in) Water/Cement ratio = 0 45 iv) Special Inspection shall be provided 27 Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (required by the soil report - page 9) 28 Show height of all foundation walls Chapter 16 29 Show height of retained earth on all foundation walls Chapter 16 Carlsbad 03-1766 July 1O, 2003 30 Show distance from foundation to edge of cut or fill slopes ("distance-to- daylight") and show slope and heights of cuts and fills Chapter 18 31 Note on plans that surface water will dram away from building and show drainage pattern Section 1804 7 32 Show foundation bolt size and spacing Foundation bolt size and spacing for shear walls must be clearly shown on the foundation plan Section 1806 6 33 The following anchor bolt requirements shall apply in Seismic Zones 3 and 4, per Section 18066 1 a) The minimum nominal anchor bolt diameter shall be 5/8-inch (for Seismic Zone 4 only) Note This will require a minimum distance from the ends of sill plates to be 4-3/8" (and a maximum of 12") b) Plate washers (minimum size of 2" x 2" x 3/16") shall be used on each anchor bolt 34 Specify size, I C B O number and manufacturer of power driven pins, expansion anchors or epoxy anchors Show edge and end distances and spacing Section 10633 35 If required, show size, embedment and location of hold down anchors on foundation plan Section 106 3 3 36 If hold downs are required, note on plan that hold down anchors must be tied in place prior to foundation inspection Section 108 5 2 • FRAMING 37 Show blocking at ends and at supports of floor joists, rafters and trusses at exterior walls Section 2320 8 3 38 Bearing partitions, perpendicular to joists, shall not be offset from supporting girders, beams, walls or partitions, more than the depth of the joist Section 2320 8 5 39 Show or note fire stops at the following locations per Section 708 2 1 a) In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10 foot intervals both vertical and horizontal, b) At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings, c) In concealed spaces between stair stringers at the top and bottom of the run and between studs along and mime with the run of stairs if the walls under the stairs are unfinished, d) In openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials e) At openings between attic spaces and chimney chases for factory-built chimneys Carlsbad 03-1766 July 1O, 20O3 40 Show double top plate with minimum 48" lap splice Section 2320 11 2 41 Show nailing will be in compliance with Table 23-I1-B-1 42 Detail all post-to-beam and post-to-footing connections and reference the detail to the plan Section 2314 43 Provide roof framing plan and floor framing plan Section 106 3 3 a) The roof rafters are missing 44 Show rafter ties Rafter ties shall be spaced not more than 4 feet on center and be just above the ceiling joists, where rafters and ceiling joists are not parallel Section 2320 12 6 a) This correction will be rechecked after the roof rafters are shown on the roof framing plan 45 Provide calculations for mam vertical and horizontal framing members and footings Section 10633 a) A complete structural recheck will be done after the structural calculations are provided 46 Provide calculations for lateral loads, shear panels, shear transfer and related Section 10633 a) A complete structural recheck will be done after the structural calculations are provided 47 Detail shear transfer connections, including roof and floor diaphragms, to shear walls Section 2315 48 Specify nail size and spacing for all shear walls, floor and roof diaphragms Indicate required blocking Maintain maximum diaphragm dimension ratios Sections 2315 and 2513 49 The minimum length of all shear walls shall be specified at each location on the structural plans 50 In Seismic Zone 4, aspect ratios are limited to 2 1 for wood shear panels Table 23-ll-G a) This correction will be rechecked after the information required under correction # 49 above has been clearly shown on plans 51 Specify plywood and/or particle board thickness, grade and panel span rating Table 23-II-E-1 • MECHANICAL (UNIFORM MECHANICAL CODE) 52 Show the location, type and size (BTU's) of all heating and cooling appliances or systems Carlsbad O3-1766 July 1O, 2OO3 53 Show source of combustion air to furnace, per Chapter 7, UMC Specify the location and sizes of both of the combustion air openings 54 Specify on the plans the following information for the fireplace(s), per Section 10633 a) Manufacturer's name b) Model name/number c) ICBO approval number, or equal d) Show height of chimney above roof per ICBO approval or UBC Table 31-B e) Note on the plans that approved spark arresters shall be installed on all chimneys UBC, Section 3102 3 8 • ELECTRICAL (NATIONAL ELECTRICAL CODE) 55 Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels If service is over 200 amps, submit single line diagram, panel schedule and load calculations 56 Note on the plans that receptacle outlet locations will comply with NEC Art 210-52(a) 57 Show on the plans that countertop receptacle outlets comply with NEC Art 210-52(c), which reads as follows In kitchens and dining areas of dwelling units a receptacle outlet shall be installed at each counter space wider than 12 inches Receptacles shall be installed so that no point along the wall line is more than 24 inches measured horizontally from a receptacle outlet in that space Island and peninsular countertops 12 inches by 24" long (or greater) shall have at least one receptacle Countertop spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces 58 Per NEC Art 210-11(c)3, note on the plans that bathroom circuiting shall be either a) A 20 ampere circuit dedicated to each bathroom, or b) At least one 20 ampere circuit supplying only bathroom receptacle outlets 59 Show at least one wall switch-controlled lighting outlet to be installed in every habitable room, in bathrooms, hallways, stairways, attached garages, and detached garages with electric power, and at the exterior side of outdoor entrances or exits At interior stairways show 3-way switching for lighting outlets at each floor level where there are six or more steps NEC Art 210(a) 60 Show on the plan that ground-fault circuit-interrupter protection complies with NEC Art 210-8, which reads as follows All 125-volt, single-phase, 15- and 20- ampere receptacles installed in bathrooms, garages, basements, outdoors, kitchen counters and at wet bar sinks Carlsbad O3-1766 July 1O, 20O3 61 All bedroom branch circuits now require arc fault protection Note clearly on the plans that "Bedroom branch circuits will be arc fault circuit protected " NEC Art 210-12(b) • PLUMBING (UNIFORM PLUMBING CODE) 62 Show water heater size (1st hour rating), type, and location on plans UPC, Section 501 0 63 Note on the plans that "Combustion air for fuel burning water heaters will be provided in accordance with UPC Section 507 and Table 5-1" 64 Show T and P valve on water heater and show route of discharge line to exterior UPC, Section 608 5 65. In Seismic Zones 3 and 4, show that water heater is adequately braced to resist seismic forces Provide two straps (one strap at top 1/3 of the tank and one strap at bottom 1/3 of the tank) UPC, Section 510 5 • ENERGY CONSERVATION 66 Provide plans, calculations and worksheets to show compliance with current energy standards 67 The window schedule shall clearly describe the required U-factor and solar heat gam coefficient (SHGC) values and demonstrate compliance with the Title 24 energy calculations 68 The regulations require a properly completed and properly signed Form CF-1R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design 69 All sheets of the latest CF-1 R form must be imprinted onto the plans (sheets 1 of 3, 2 of 3 and 3 of 3 must be included) 70 All energy items shown on the plans must be in agreement with the information shown on the properly completed Form CF-IR 71 Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Measures Checklist" 72 Show the make, model, type and efficiency of the space heating (or cooling) system 73 Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen(s) and bathrooms (containing a tub or shower) Carlsbad 03-1766 July 1O, 2003 74 Note on the plans "The manufactured windows shall have a label attached certified by the National Fenestration Rating Council (NFRC) and showing compliance with the energy calculations " CARLSBAD SPECIAL CODE REQUIREMENTS 75 Special inspection is required, the designer shall complete the attached Special Inspection Notice 76 New residential units must be pre-plumbed for future solar water heating Note "two roof jacks must be installed" where the water heater is in the one story garage and directly below the most south facing roof (City Ordinance No 8093) 77 Note "two 3/4" copper pipes must be installed to the most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof (City Ordinance No 8093) 78 All piping for present or future solar water heating must be insulated when in areas that are not heated or cooled by mechanical means (City Policy) To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation Thank you Carlsbad O3-1766 July 10, 2003 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No 03-1766 Job Address or Legal Description 133O Cynthia Ln. Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet (over) Carlsbad 03-1766 July 10, 2003 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION PLAN CHECK NUMBER. OWNER'S NAME I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special mspector(s) as required by Uniform Building Code (DEC) Section 1701 1 for the construction project located at the site listed above UBC Section 106 3 5 Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106 3 5 for the construction project located at the site listed above Engineer's/Architect s Seal & Signature Here Signed 1 List of work requiring special inspection: D Soils Compliance Prior to Foundation Inspection LH Field Welding D Structural Concrete Over 2500 PSI D High Strength Bolting n Prestressed Concrete D Expansion/Epoxy Anchors D Structural Masonry D Sprayed-On Fireproofmg D Designer Specified D Other 2 Name(s) of mdividual(s) or firm(s) responsible for the special inspections listed above A B C 3 Duties of the special inspectors for the work listed above: A B. C. Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site Carlsbad O3-1766 July 1O, 2003 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PREPARED BY Sergio Azuela BUILDING ADDRESS 1330 Cynthia Ln. BUILDING OCCUPANCY R-3 & U-l PLAN CHECK NO O3-1766 DATE July 10, 2003 SFD for Richard Gilbert TYPE OF CONSTRUCTION V-N BUILDING PORTION Dwelling Basement Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 1558 781 1558 cb Valuation Multiplier 8200 21 00 300 By Ordinance Reg Mod VALUE ($) 127,756 16,401 4,674 148,831 1994 UBC Building Permit Fee 1994 UBC Plan Check Fee Type of Review C] Repetitive Fee ^j Repeats Complete Review D Other i—i Hourly Structural Only Hour Esgil Plan Review Fee Comments $697 48 $453 36 $390 59 Sheet 1 of 2 macvalue doc Carlsbad 03-1766 July 1O, 2003 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PREPARED BY Sergio Azuela BUILDING ADDRESS 1330 Cynthia Ln. BUILDING OCCUPANCY R-3 & U-l PLAN CHECK NO 03-1766 DATE July 10, 2003 SFD for Richard Gilbert TYPE OF CONSTRUCTION V-N BUILDING PORTION Det Garage Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq Ft ) 484 cb Valuation Multiplier 2300 By Ordinance Reg Mod VALUE ($) 11,132 11,132 1994 UBC Building Permit Fee 1994 UBC Plan Check Fee Type of Review D Repetitive Fee V~! Repeats Complete Review D Other r-i Hourly Structural Only Hour* Esgil Plan Review Fee Comments $11509 $7481 $6445 Sheet 2 of 2 macvalue doc City of Carlsbad P u b I i <c SWb r ks ^^ E n g i n e e r i n g BUILDING PLANCHECK CHECKLIST DATE BUILDING ADDRESS PROJECT DESCRIPTION ASSESSOR'S PARCEL NUMBER PLANCHECK NO CB ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build D A Right-of-Way permit is required prior to construction of the following improvements EST VALUE DENIAL Please see/'toe attached report of deficiencies marked wiUi D )Make necessary corrections to plans or specificattons for compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review By By Date Date Date By FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT Date ATTACHMENTS D Dedication Application Q Dedication Checklist D Improvement Application D Improvement Checklist D Future Improvement Agreement D Grading Permit Application D Grading Submittal Checklist [] Right-of-Way Permit Application rj Right-of-Way Permit Submittal Checklist and Information Sheet D Sewer Fee Information Sheet ENGINEERING DEPT CONTACT PERSON Name TAN|YA BARROWS City of Carlsbad Address 1635 Faraday Avenue, Carlsbad, CA 92008 Phone (760) 602-2773 CFD INFORMATION Parcel Map No Lots Recordation Carlsbad Tract 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-272O • FAX (76O) 6O2-8562 F \BUILDINGPLANCHECKCKLST FORM doc j Rev 7/14/00 BUILDING PLANCHECK CHECKLIST SITE PLAN 1 Provide a fully dimensioned site plan drawn to scale Show s#^ North Arrow .-B-"Existing & Proposed Structures G- Existing Street Improvements Property Lines -c 'Easements 2 Show on site plan -F- Right-of-Way Width & Adjacent Streets J2r Driveway widths -H Existing or proposed sewer lateral 4" Existing or proposed water service J Existing or proposed irrigation service A Drainage Patterns 1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course 2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building " B Existing & Proposed Slopes and Topography C Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception D Sewer and water laterals should not be located within proposed driveways, per standards D D 3 Include on title sheet ,«• Site address sessor's Parcel Number - Legal Description ~ ir\d For commercial/industrial buildings and tenant improvement projects, include total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc) previously approved EXISTING PERMIT NUMBER DESCRIPTION F \BUILDINQ PUNCH6CK CKLST FORM doc BUILDING PLANCHECK CHECKLIST 3RD DISCRETIONARY APPROVAL COMPLIANCE HI 4a Project does not comply with the following Engineering Conditions of approval for Project No D D D 4b All conditions are in compliance Date DEDICATION REQUIREMENTS [U 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm dram or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 15.000 . pursuant to Carlsbad rrM (jkf Municipal Code Section 18 40 030 Dedication required as follows \STU Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 1/z" x 11" plat map and submit with a title report All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit Attached please find an application form and submittal checklist for the dedication process Submit the completed application form with the required checklist items and fees to the Engineering Department in person Applications will not be accept by mail or fax Dedication completed by Date IMPROVEMENT REQUIREMENTS 6a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 75.000 . pursuant to Carlsbad Municipal Code Section 1840040 Public improvements required as follows Attached please find an application form and submittal checklist for the public improvement requirements A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process The completed application form and the requirements on the F \BUILDINO PLANCHECK CKLST FORM doc BUILDING PLANCHECK CHECKLIST iST -.ND ,RD D checklist must be submitted in person Applications by mail or fax are not accepted Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit Improvement Plans signed by Date 6b Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 1840 Please submit a recent property title report or current grant deed on the property and processing fee of $310 so we may prepare the necessary Neighborhood Improvement Agreement This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit Future public improvements required as follows D D D D D 6c Enclosed please find your Neighborhood Improvement Agreement Please return agreement signed and notarized to the Engineering Department Neighborhood Improvement Agreement completed by Date 6d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy D GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section ^ 06 030 of the Municipal Code 7a Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities (cut, fill import, export) 7b Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit Grading Inspector sign off by Date 7c Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) F1BUILDING PUNCHECK CKLST FORM doc BUILDING PLANCHECK CHECKLIST ^ST 2ND 3RD D D D 7d No Grading Permit required D D D 7e If grading is not required, write "No Grading" on plot plan MISCELLANEOUS PERMITS D D D 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way Types of work include, but are not limited to street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities Right-of-Way permit required for D D D 9 INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List You may telephone (760) 438-2722, extension 7153, for assistance Industrial Waste permit accepted by Date 10 NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first 11 CZKRequired fees are attached Q No fees required WATER METER REVIEW D D D 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low-flow conditions If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used • All single family dwelling units received "standard" 1" service with 5/8" service F \BUILOINQ PLANCHECK CKLST FORM doc ,ST jRD n n n 12b BUILDING PLANCHECK CHECKLIST • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm) A typical fixture count and water demand worksheet is attached Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit • Maximum service and meter size is a 2" service with a 2" meter • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand (manifolds are considered on case by case basis to limit multiple trenching into the street) Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval The developer must provide these calculations Please follow these guidelines 1 If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets If so, at the water meter station, the demand in gpm may be listed there Irrigation services are listed with a circled "I", and potable water is typically a circled "W" The irrigation service should look like STA1+00 Install 2" service and 5 meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach) Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use Once you have received a good example of irrigation calculations, keep a set for your reference In general the calculations will include • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA) As long as the project is located within the City recycled water F BUILDING PLANCHECK CKLST FORM doc Rev 7/14/00 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future D D D 12c Irrigation Use (where recycled water is available) 1 Recycled water meters are sized the same as the irrigation meter above 2 If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development For subdivisions, this should have been identified, and implemented on the improvement plans Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this 13 Additional Comments: F \BUILDING PLANCHECK CKLST FORM doc Rev 7/14/00 ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D Estimate based on unconfirmed information from applicant ^- Calculation based on building plancheck plan submittal Address i-33^ O/AHl/V ^ Bldg Permit No £|S #3- Prepared by "^ U EDU CALCULATIONS List Types of Use <^f=' r\ Types of Use APT CALCULATIONS Types of Use f-^-h^ Types of Use i Date types ant List types and ?, FEES REQUIRED :+-l3d/C)5 Checked by dsqi Sq Sq squ Sq Sq jare footages Ft /Units Ft /Units for all uses \ are footages for all uses Ft /Units I Ft /Units EDU EDU Date 's 's I ADT's / ADT's WITHIN CFD D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) BH PARK-IN-LIEU FEE FEE/UNIT PARK AREA & # X NO UNITS -2 TRAFFIC IMPACT FEE ADT's/UNITS FEE/ADT =$_ 0-3 BRIDGE AND THOROUGHFARE FEE ADT's/UNITS •Ef-4 FACILITIES MANAGEMENT FEE UNIT/SO FT &- 5 SEWER FEE EDU's ^ / BENEFIT AREA EDU's D 6 SEWER LATERAL ($2,500) B- 7 DRAINAGE FEES PLDA ACRES (DIST #1 DIST #2 X FEE/ADT ZONE X FEE/SO FT /UNIT X FEE/EDU &€>uD X FEE/EDU HIGH /LOW X FEE/AC DIST #3 ) =$ =$ -1&C&Q =$ =$ 8 POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATIONwo F \FEE CALCULATION WORKSHEET doc 1 of 2 Rev 7/14/00 ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D 9 RECLAIMED WATER FEES UNITS CODE CONNECTION FEE METER FEE TOTAL OF ABOVE FEES* $ *NOTE This calculation sheet is NOT a complete list of all fees which may be due Dedications and Improvements may also be required with Building Permits 2 of 2 F \FEE CALCULATION WORKSHEET doc Rev 7/14/00 D \;D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check Planner APN Type of Project & Use Zoning 4^--( General Plan CFD (m/out) #_Date of participation Net Project Density DU/AC Facilities Management Zone _ Remaining net dev acres. Circle One (For non-residential development Type of land used created by this permit ) Legend ^ Item Complete D Item Incomplete - Needs your action Environmental Review Required YES _\NO(V__ TYPE DATE OF COMPLETION f Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/PESO NO PROJECT NO YES NO TYPE DATE OTHER RELATED CASES Compliance with conditions or approval7 If not, state conditions which require action Conditions of Approval NO_ NO Coastal Zone Assessment/Compliance Project site located in Coastal Zone7 YES_ CA Coastal Commission Authority7 YES If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402, (619) 767-2370 Determine status (Coastal Permit Required or Exempt) Coastal Permit Determination Form already completed7 YES NO If NO, complete Coastal Permit Determination Form now Coastal Permit Determination Log # L3 D D Follow-Up Actions 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans) 2) Complete Coastal Permit Determination Log as needed *s Inclusionary Housing Fee required YES/X NO (Effective date of Inclusionary Housing Ordmarice^- May 21, 1993 ) NOData Entry Completed7 YES. (A/P/Ds, Activity Maintenance?, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE") Site Plan H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 D D 1 Provide a fully dimensional site plan drawn to scale Show North arrow property lines easements, existing and proposed structures, streets, existing street improvements nght-of-wa\ width, dimensional setbacks and existing topographical lines (including all side and rear vard slopes) g££ J,efou 4, 2 Provide legal description of property and assessors parcel number Policy 44 - Neighborhood Architectural Design Guidelines 1 Applicability YES. jf> NO 2 Project complies YE Zoning 1 Setbacks / Front Interior Side Street Side Rear Top of slope 2 Accessory structure Front Interior Side Street Side Rear Structure separation 3 Lot Coverage S V/NO Required Required Required Required Required setbacks Required Required Required Required Required Required fO _ / Shown ^tS/, <5 ' ft.. Shown ^£_^feg£ Shown """' 1 3- ' Shown ~7 /t?- ' Shown {7& Shown >^^ T"' Shown ' &f 1 Shown S " Shown / 2- f /fo .Shown "~7/£3 — ^ /U /A Shown C& /* 4 Height Required Shown Spaces Required Shown5 Parking (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown £>/ Additional Comments OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01