HomeMy WebLinkAbout1332 CORVIDAE ST; ; CB970371; PermitBUILDING PERMIT Permit Wo CB9703/1
02/26/57 15 17 Project Wo A9700513
Page 1 of 1 Development No
Job Address 1332 CORVIDAE ST Suite
Pezmit Type PATIO/DECK ' 25Oj ^ .„
Parcel No 215-691-35-00 Lot# "'" " w/-6/97 CCCi 01 02
Valuation 1,053 Construction TygjFpty-iSiSW o~aO'j
Occupancy Group Referen.ce*
Description 156 SF PATIO COVER, GAS LINE
Ai\,D ELECTRICAL LINE
Appl/Ownr rfuGHES, JAMES
^332 CORVIDAE STREET
CARLSBAD, CA 92009
f A- i Fees Required *<.-;>• **v '
Status' ISSUED
Applied 02/25/97
Apr/Issue 02/26/97
Ertered Bv JM
619 942-5622.
'•=<?s Collected & Credits
Fees
Adjustments
Total Fees
Fee description
93 00
r< I:
e .Due,
00
OJ
93 00
Ext fee Data
Building Permit
Plan Check
Strong Motion Fee
Other
A BUILDING TOTAL
27 00
18 00
1 Oi»
47 00 ELEC&PLUM
CITY OF CAFqS&AD
2075 Las Palmas Dr , Carlsbad, CA 92009 (619) 438-1161
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
2075 Las Palmas Dr , Carlsbad CA 92009
(619) 438-1161
INFORMATION- K:-?i.....'.:-:!.:
Z. " "
FOR OFFICE USE ONLY
PLAN CHECK NO
EST VAL
Plan Ck Deposit
Validated By u
Date
Address (include Bldg/Suite *)Business Name (at this address)
Legal Descnption Lot No Subdivision Name/Number Unit No Phase No Total # of units
Assessor s Parcel
Description of Work
/^g-
Existing Use i (\<&^ m. > (^s LJ/~I<^-
' "ScTFT ' ' #of Stories
Proposed Use
# of Bedrooms # of Bathrooms
CONTACT PERSON (if dWerent from applicant)
Name Address
3. :^ APPLICANT Q Contractor.... Q:Ao,ent for Contractor
City
Agent fpr Owner ....
State/Zip Telephone #Fax #
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its
issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law
(Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom and the basis for the alleged
exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001)L A. ^- _^-> . ^—-/O__.l ^—^ ^t >> ^— ir~ii i~t—/n* .. s~\f> v^L \s- -. iZX ^, O — CZoP^
Name
State License #
Address l
License ClasS^l-2''? l&]
City State/Zip "*
' ^*T"( City Business License tt
Telephone #
Designer Name
State License tt
Address City State/Zip Telephone
..WORKERS'. COMPENSATION^
Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
[~l | have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance
of the work for which this permit is issued
Q I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is
issued My worker s compensation insurance earner and policy number are
Insurance Company _ Policy No _ Expiration Date _
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
Q CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as
to become subject to the Workers Compensation Laws of California
WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to cnminal penalties and civil fines up to one hundred
thousand dollars ($100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labqr code interest and attorney t fee's
SIGNATURE _ DATE _
7 OWNER BUILDER DECLARATION , .... . ;,*•£
I hereby affirm that I am exempt from the Contractor s License Law for the following reason
\S'\ as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale
(Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does
such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is
sold within one year of completion the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)
Q^""i as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The
Contractor s License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant'to the Contractor s License Law)
l am exempt under Section _ Business and Professions Code for this reason
/
4 I plan to provide portions of the work but I h
number / contractors license number)
5 I will provide some of the
of work) ~
I personally plan to provide the major labor and materials for construction of the proposed property improvement Q"YES
I (have / have not) signed an application for a building permit for the proposed work
I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone numl
_£j!3Z+^F2>&nk £>4-0 -£>f>Ljrtt*«^W ' " - - -
•actors license numberl
I C ?~l
following person to coordinate supervise and provide the major work (include name I address / phone3/KT&—
ive contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
PROPERTY OWNER SIGNATURE
.COMPLETE THIS SECTION. FOR
Is tf-9 applicant o future fcuiid r.g occupant isqiured to submit a bu&me&s plan acutely hazardous materials registration form or nsk management and prevention
program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? Q YES Q NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO
Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? Q YES Q NO
IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
8v CONSTRUCTION LENDING AGENCY ,V •-"'i;"-J-.' ,. "" "•'-'" "•"-• ^SC '•
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code)
LENDER S NAME LENDER S ADDRESS
3 APPLICANT CERTIFICATION " " •• ./'"•.-"• ••:. '2Sii?r^?k ""•"
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES
JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5 0' deep and demolition or construction of structures over 3 stories in height
EXPIRATION Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or
work authorized by such permit is not commenced with n 3o5 days from the date of such permit or if the building or work authorized by such permit is suspended
or abandoned at any time after the work is cgmmpytyS Jjor^jienod of 180 days (Section 106 4 4 Uniform Building Code)
APPLICANT S SIGNATURE DATE
WHITE File YELLOW Applicant PINK Finance
City of Carlsbad
Building Department
July 19, 1997
JAMES HUGHES
1332 CORVIDAE ST
CARLSBAD CA 92009
RE BUILDING PERMIT EXPIRATION
Permit Number
Issue Date
CB970371
02/26/97
PLEASE CALL FOR AN
INSPECTION IF WORK IS
COMPLETE
ADDRESS 1332 CORVIDAE ST
Our records indicate that your building permit will expire by limitation of time on 8/30/97
The provisions of UBC, Section 303(d) state "EXPIRATION Every permit issued by the Building
Official under the provisions of this code shall expire by limitation and become null and void if the building
or work authorized by such permit is not commenced within one calendar year from the date of such permit,
or if the building or work authorized by such permit is stopped at any time after the work is commenced for
a period of six consecutive calendar months or if the building or work authorized by such permit exceeds
three calendar years from the issuance date of permit Work shall be presumed to have commenced if the
permittee has obtained a required inspection approval of work authorized by the permit by the Building
Official within one year of the date of permit issuance Work shall be presumed to be stopped if the
permittee has not obtained a required inspection approval of work by the Building Official within each six
month period upon the initial commencement of work authorized by such permit "
Before such work can be recommenced, a new permit, or a renewal permit as specified in the attached copy
of the code, shall be obtained
Any person holding an unexpired permit may apply for an extension of the time within which he may
commence work under that permit when he is unable to commence work within the time required by this
section for good and satisfactory reasons The Building Official may extend the time for action by the
permittee for a period not exceeding 180 days upon written request by the permittee showing that
circumstances beyond the control of the permittee have prevented action from being taken No permit shall
be extended more than once
Please check below indicating your intentions and return this letter to us
Project abandoned A new permit will be obtained prior to commencing work
No fee extension requested for 180 days (attach a letter of explanation)
Renewal permit requested
If the project has been completed and only a final inspection is needed, please call the inspection request line
at (760) 438-3101
If you have any questions, please contact the Building Inspection Department at (760) 438-3550
PAT KELLEY
Principal Building Inspector
Attachment
2O75 Las Palmas Dr • Carlsbad CA 92OO9-1576 • (619) 438-1161 • FAX (619) 438-O894
07/12/97 INSPECTION HISTORY LISTING
FOR PERMIT# CB970371
DATE
05/06/97
05/06/97
05/06/97
05/06/97
03/03/97
03/03/97
03/03/97
03/03/97
03/03/97
03/03/97
INSPECTION TYPE
Final Structural
Final Structural
Gas/Test/Repairs
Gas/Test/Repairs
Ftg/Foundation/Piers
Ftg/Foundation/Piers
Gas/Test/Repairs
Gas/Test/Repairs
INSP ACT COMMENTS
RI
PD
RI
PD
RI
DC
RI
DC
Underground/Conduit-Wir RI
Underground/Conduit-Wir DC
RI
CO
RI
CO
RI
CO
RI
AP
RI
AP
RSMATT
ON CARD
RSMATT
BJN/MATT/
NO PLANS 1:30
BJN/MATT/
3:30
BJN/MATT/
HIT <RETURN> TO CONTINUE...
CITY OF CARLSBAD
INSPECTION REQUEST
PERMIT* CB970371 FOR 08/18/97
DESCRIPTION: 156 SF PATIO COVER, GAS LINE
AND ELECTRICAL LINE
TYPE: PATIO
JOB ADDRESS:1332 CORVIDAE ST
APPLICANT: HUGHES, JAMES
CONTRACTOR:
OWNER:
REMARKS: C/JAMES/603-9770
SPECIAL INSTRUCT:
PHONE:
PHONE:
PHONE:
INSPECTOR AREA DC
PLANCK# CB970371
OCC GRP
CONSTR. TYPE NEW
STE: LOT:
619 942-5622
INSPECTO
TOTAL TIME:
CD LVL DESCRIPTION
19
29
39
ACT COMMENTS
ST Final Structural
PL Final Plumbing
EL Final Electrical
***** INSPECTION HISTORY *****
DATE DESCRIPTION ACT INSP COMMENTS
050697 Final Structural CO PD ON CARD
050697 Gas/Test/Repairs CO PD
030397 Ftg/Foundation/Piers CO DC NO PLANS
030397 Gas/Test/Repairs AP DC 3:30
030397 Underground/Conduit-Wiring AP DC
1:30
m
£> «4&fejw-
*&
%<6 ^
City of Carlsbad
Building Department
RESIDENTIAL PATIO COVERS
Patio covers are one story, roofed structures not more than 12 feet above grade and
used for outdoor recreational purposes A Building Permit is required for patio covers
attached to a residence Residential patio covers less than 300 square feet in size and
at least ten feet from any other structure on the lot do not require a building permit from
the City But all patio covers, permitted or not, must comply with the setback
requirements in this handout This hand out describes what plans are necessary to
secure a patio cover permit To assist you, there is a sample of a plot plan, span tables
for joists, and beams, and there is a footing schedule for foundation requirements
There are also connection details to use for typical connections You may use this
handout in lieu of a separate design If you design the patio cover yourself, or your patio
cover is outside the span table limits in this handout, please provide a foundation plan,
framing details, and other details and elevations to show the extent of the proposed
work
If you use the attached tables and plans please submit
1 Two Identical Site Plans showing
a) Property lines with dimensions
b) Proposed roof area of the patio cover
c) Distances from posts to property lines
d) All existing structures on the property
e) Indicate the dimensions of the patio cover and the total roofed area
f) Any easements on the property
g) Show slopes or topography of the lot
2 A Building Permit Application with the following
a Name of the property owner
b Home Phone Number
c Site address, assessor's parcel number, lot number, subdivision name or
number
d Contractor's name, State License Number and City Business License
Number, or an Owner-Builder Declaration Form (Available at the Building
Department Counter)
e Signature of Applicant
If you are applying for a building permit in the Coastal Zone you may need a Coastal development Permit or an exemption Contact
the Planning Department for details A Coastal Zone map is part of this handout If you are applying for a building permit in a
subdivision with a homeowners association you should secure architectural review prior to proceeding with the project The City
does not enforce or specifically review provisions of homeowners association CC&R s HOA requirements may be different than
City requirements If your home is part of a Planned Unit Development or a condominium please see text of this handout
Revised 10 3 96
1
2O75 Las Palmas Dr • Carlsbad, CA 92OO9-1576 • (619) 438-1161 • FAX (619) 438-O894
TYPICAL R 1 PLOT PLAN
SETBACKS FOR R 1 PARCELS
FRONT YARD 20 from front
property line
INTERIOR SIDE YARD 10% of
lot width up to a maximum of
10 (Mm 5')
STREET SIDE YARD 10
REAR YARD 20% of tot width
up to maximum of 20 feet (Mm 10)
MAX LOT COVERAGE 40%
Contact the Planning Department
for information on corner lots or
lots with unusual configurations
and for information on Planned
Communities accessory
structures and building
heights
The telephone number for the
Planning Department is
4381161
1
20% of LOT
X- REAR YARD WIDTH TO A \
(
10%,
VDF
£-.
MAX OF 20
fV'i -***'! V -'.'Jl'":'.":''~:'pRopbsED *%:;"'.••:"-AMJrrioN. :'•'•;'."-
J:;^fi- :Mf
EXISTING RESIDENCE
XAINAGE 2% MIN
20
L
V
^— i — :
^/~
/ \
STREET
10% OF
LOT WIDTH
UP TO A
MAX OF 10
LOT WIDTH MEASURED 20
"FROM 20 BACK OF
FRONT PROPERTY LINE
PROPERTY LINE
Minimum Square Footing Sizes (inches)12
Post
Spacing
4
6
^•8~~-v
10;
-^1
14
16
18
20
6
12
12
12
12
12
12
12
12
14
^8 \
12 x
12
12
12
12
12
14
14
14
— x
10 ]
^2^12
12
12
14
14
14
16
16
Joist
Span
(feet)
12
12
12
12
14
14
16
16
18
18
14
12
12
12
14
16
16
18
18
20
16
12
12
14
14
16
18
18
20
20
18
12
12
14
16
18
18
20
20
22
20
12
14
14
16
18
20
20
22
24
1 Assumes 1 000 psf soil bearing capacity
2 The minimum depth for all footings is 12 inches into natural grade
Patio Cover
Minimum Rafter Sizes
Rafter
Span
(feet)
6 -r ::;:.
7
8 ':;T. --.^
-^-MO /^r
£12
13
.'1<4 <;*pk, .;
15
J6 '• i" "
17
1 8 i£V *:<!
19
,20 - '*
Rafter Spacmq Center to
12" (5/16" ply-
wood sheathing)
Xif*-~2-x$;-xiv&;/
2x4
^ Av^ •• ' . -..'^
2x4
2x6-
2x6
* iMts*'2<x!6?r^
2x6
2x6
2x6
2x8
2x8
HlllC^Pt.lgi.,
2x8
'" - 2 x 8,. "• -
16" (1/2" ply-
wood
sheathing)
', 2*V^!g
2x4
2 x^« - *•••
2x6
1 2 x 6
2x6
: >2%6
2x6
:ifr2<.XS6 ;
2x8
,^,2x8 '^
2x8
-2xJ8^^
2x10
2"x 10
Center (inches)
24" (1/2" ply-
wood sheathing)
£ • 2*^^.. •(
2x4
^.^2oc*6 •
2x6
^.fT? 2x6
2x6
,-,; 2x6
2x8
; 2x8
2x8
tw 2x8^-^.. >
2x10
2X|10
2x10
2x10
32" (5/8" ply-
wood sheathing)
2x4 "\
2x4
2x6
2x6
..•.-^ax^' ^
2x8
• . ^<2-x 83&- ^
2x8
2x8 O!
2x10
- . 2x10^,.
2x10
2x10,,: ,
2x12
2x12 ^^.
Patio Cover
Minimum Beam Sizes
Post
Spacm
g (feet)
•A-
6
,3-^
10 }
^T2^ ...»
14
16
18
20
Rafter Span (in
feet)
4
4x4
4x4
4x4,;,;:
4x4
?4"x 6 ^
4x6
4x8"
4x8
4 x,8
6x8
6
4x4
4x4
4x4
4x6
4x6
4x8
4x8
4x8
6x8
4x10
6x,8-
8 (
4x4 "
4x4
4x6
4x6
4x8
4x8
4x8
6x8
4x10
6x8
4x10
6x10
10 )
~*TC%
4x4
4'x6
4x6
4,x8
'-?'
4x8
,4x10
6x8
4x10
6x8
4x12
6x10
12
4X<;4
4x4
4x6
4x6
4x8
4x8
6x8
4x10
6x8
4x10
6x10
4x12
6x10
14
4x4
4x4
4x6
4x6
4x8
6x8
4x10
6x8
4x10
6x10
4x12
6x 10
4x14
6x12
16
M,x 4
4x4
4x6
4x8
4x8
6x8
4x10
6x10
4x12
6x10
4x12
6x10
4x14
6x12
18
4x4
4x4
4x6
4x8
4x8
6x8
4x10
6x10
4x12
6x10
4x14
6x12
6x12
20
4x4
4x6
4x6
4x8
4x1%"6~'x8 %;
4x10
6x10
4 xs14^
6xVlO'-
4x14
6x12
' \V-
"eVift.,..
TYPICAL PATIO COVER DETAILS
Figure 1/Typical patio construction
For ledger to
unit attachment
see text
6 minimum
Post spacing
Continuous
solid blocking
between joists
more than 8 in
depth
Figure 2/Connection anchor and footing details
Case 1/Connection end condition
7 gauge steel Lstrap 2Vj wide
with tour V, g bolls8" along beam
12 along post
Case 3/Anchor and footing detail integrated slab
T-0 minimum if required windows
between patio and dwelling unit
See footing details below
Case 2/Connection interior condition
7 gauge steel T
strap 2'/, widewith 6 >/, 0 bolts
16 along beam
12 along post
Case 4/Anchor and footing detail isolated pier
K6-
Natural grade
Post elevated
1 minimum
above concrete
or provide treated
wood 3V,
12
L
RS5K55 ^o^'sfe oC .»&
Figure 3/Enclosed patio section Figure 4/Encbsed patio interior elevation
Insect screening or
transparent plastic0 125 maximum DweBmgthickness unit
Concrete slab
V,e * 'Vmaximum mesh
y- insect screening or
' plastic screening
Nonbeanng wall
.only between
roof supporting
members
PATIO COVER CONSTRUCTION SPECIFICATIONS
1 Concrete
a) All concrete for footings must be a minimum of 2,000 psi
2 Lumber
a) Lumber must be Douglas Fir-larch No 2 or Better Lumber must be grade marked All posts
must be a minimum of 4x4 and may be required to be protected from decay and termites if
within 6" of finish grade
3 Connections
a) Post anchorage may be accomplished with a standard manufactured post base installed per
the manufacturer's instructions Footings are required when the post supports a load
exceeding 750 pounds For lesser loads, a 3 Yz" slab on grade section may be substituted for
required footings
b) When the house is used to support one end of the patio cover the mam beam may be
replaced on the side attached to the house by a ledger The ledger shall be the same size as
the rafters and fastened to the structural frame of the house by Yt" x 5" lag screws spaced at
32" on center for rafters up to a 10' span Lag screws must be spaced at 16" on center for
rafters between 10'1" and 20' Rafters may not be solely supported by the existing rafter tails
or facia of the house
4 Patio Enclosures
a) Patios may be enclosed as long as the following criteria is followed
1) The enclosure walls may have any configuration provided the open area of the longer
wall and one additional wall is equal to at least 65% of the area below 6'8" of each
wall as measured form the floor (see City of San Diego Building Newsletter 31-
2) Openings may be enclosed with insect screening or plastic that is readily removable
translucent or transparent plastic not more than 1/8" in thickness ( See figures 3 and
4 above)
3) A patio enclosure requires a permit The permit may be issued as part of the original
patio cover permit, or it may be obtained at a later time Enclosures may be used for
outdoor recreational purposes only Patio enclosures may not be used as habitable
space
5 Tables
a) The above span and footing tables make the following assumptions
1) Roof live load is 10 psf
2) Roof dead load is 7 psf
3) All lumber is Douglas fir-larch No 2 or Better,
Fb=825psi
Fv = 90 psi
E =1,200,000 psi
Repetitive member use
All posts are 4x4 minimum
Soil bearing pressure is 1000 psf minimum
6 Electrical
a) All electrical work in a patio cover or enclosure shall be weather tight as for exterior
installations
7 Inspections
1) Normally two inspections of a patio cover are required
1) When footings have been excavated but before concrete has been placed, (note
photographs of footings are not an acceptable substitute for an inspection of required
footings)
2) When all structural framing is completed
Note The project is not legally complete until the inspector of record signs the space on
the job record card as final
3) The job record card and approved plans must be available for all inspections The job
record card and approved plans should then be retained by the owner as a record of
the approved construction
8 Patio covers in PUD's and Condominium projects
a) All patio covers must comply with the above requirements
b) Posts supporting the patio cover cannot be located closer than 3' to the property line
unless they are protected by one-hour construction (e g stucco)
c) The patio cover roof may only project one foot into the three foot setback area It must
also have one hour protection as noted above
d) Proof of HOA architectural approval must be shown
e) For the property lines of a project, all applicable setback requirements for the underlying
zone shall be complied with If the underlying zone is P-C, the setback requirements of
the PUD ordinance shall be complied with Setbacks for PUD's and P-C Zones may be
more restrictive than typical R-1 setbacks or minimum Building Code setbacks Contact
the planning Department for information specific to your Planned Community or
condominium project
COASTAL COMMISSION
3111 CAMINO DEL RIO NORTH, STE 2OO
SAN DIEGO, CA 92108
(619) 521-8036
VISTALACOON
COASTAL ZONE
BOUNDARY