Description: YGLESIA: 400 SF DETACHED CABANA W/ FIREPLACE
Applicant: Owner:
Patio
STEPHEN RAY
4041 Bonita Rd, Ste B
Bonita, CA 91902-1350
619-361-1331
TRUSTYGLESIA LIVING TRUST A 09-21-04
1338 Alcyon Ct
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
CARLSBAD, CA 92011
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
581473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTJON-RESIDENTIAL
Total Fees: $883.99 Total Payments To Date: $883.99
Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Final
Inspection:
Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Permit No: CBR2018-0277
Closed -Finaled
02/02/2018
03/01/2018
PB urn
6/7/2018 2:34:50PM
$0.00
$441.44
$3D9.0l
$43.00
$80.00
$3.DO
$7.54
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-6D2-8560 f I www.carlsbadca.gov
EHE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: D PLANNING D ENGINEERING
'j
, ~BUILDING OFIRE 0HEALTH 0HAZMAT/APCD
af • f Building Permit Application Plan Check No.
Est. Value
-021'1
~ Clty O 1635 Faraday Ave., Carlsbad, CA 92008
Carlsb ".l,d Ph: 760-602-2719 Fax: 760-602-8558
U email: building@carlsbadca.gov
www.carlsbadca.gov
Plan Ck. Deposit
Date'
cq -00 con
SUITE#/SPACE#/UNIT# JOB ADDRESS \ ?,8
CT/PROJECT# PHASE# # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE acc. GROUP
APPLICANT NAME
Primary Contact
ADDRESS
CITY
PHONE "
EMAIL
,,
,Jal t....1
,, STATE QZIP ,...._
\( FAX 1..1.. ff
, ,
DESIGN PR0FESS10N0 -\e_ \ti\ ~ ------
ADDRESS-'i> _:__~--~~---
l-'Ql-j / ~\~ ~"' .. ~~------
CITY '16 OC'\ ..,-e>--STATEC..A
PHONG\"'\_ ?Jct-i?,3( ['_AX __ _
EMAIL ;:;\ ~-~ J:r ey'<Cvv\cb.N_:_._Y',.Q_::i....:-;c*~---~ STATE UC.#
PATIOS (SF) DECKS (SF) FIREPLACE
YES0
PROPERTY OWNER
ADDRESS
CITY STATE ZIP
PHONE FAX
EMAIL
CONTRACTOR ·~~(Mt J, I , " . 13~.h. ( _____ _
ADDRESS / _ ~ .., cl / '.)c!_;, ~ [..., s ,r, f '-c-,rv--p-.. -"·---. -S-TA_T_E_~--ZIP/, '/ ./ "fu '/Jl\,
PHO'/;~';-:~ 7 ''/-~CC!¥ FAX ~~
EMAIL /(.' G) {'c ,)_id(/-", Jf· 5., 7~ ---
srAre LIR:# CLASS ,). CITY BU LIC #
'!' C13'f V
(Sec. 7031.5 Business and P.rofessions Code: Any City or County which requires a permit to.construct. alter, improve, demolish or repair any structure, prior to its issuan a r ires the applicant for such per.mil to file a signed statement that he is licensed pursuant to the prov1s1ons of the Contractor's License LawJChapter 9, comme_nd1ng with Section 7000 of Division 3 of th Business and Professions Code) or fuat he is exempt therefrom, and the basis for the alleged exemption. Any v1otat1on of Section 031.5 by any applicant for a permit subJects the applicant to a
civil penalty of not more than five hundred dollars {$500)).
-"-W' -
WORKERS' COMPENSATION --, , ,z, ",
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
I have and will maintain workers' comiensauon, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co.~_( . .,...,, -k li,_j..,ir ·, '\( (_ { ~' - ----Policy No. { j r 5 D I .A 2 C, 1 . Expiration Date .;J) /t) I 10,1
This section need not be completed if the permit is for one hundred dollars ($100) or less. 0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California WARNING: Failure to secure woril:ers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as P. ij for Section 3706 of the labor code, interest and attorney's fees.
fE5 CONTRACTOR SIGNATURE
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
D
D
D
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project {Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I am exempt under Section __ , ___ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0Yes 0No
2. I (have I have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number)
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work):
fE5 PROPERTY OWNER SIGNATURE 0AGENT DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? 0 Yes O No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes O No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes O No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I certifythatl have read the application and state that the above lnfmmation lsrorrectand that the Information on the plans is acx:urate. I agree to comply with all City ordinances and State laws relating to buildingronstruction.
I hereby aulhOfize representabve of the City of Cartsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS ANO EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CrTY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA: An OSHA permit is required for excavations (1oJe( 5'0' deep and demolitioo or construction of structures over 3 stories in height.
EXPIRATION: Every pennit issued by the Buikling Official under the provisions of this Code shall expire by limitation and become null and void if the building or'Mlrk authorized by such permit is not commenced within
180 days from the date of such permit or if the building or work aulhori such permit is suspen or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code).
Af5 APPLICANT'S SIGNATURE
STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
Fax (760) 602-8560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
CO#: (Office Use Only)
CONTACT NAME OCCUPANT NAME
ADDRESS BUILDING ADDRESS
CITY STATE ZIP CITY
Carlsbad
STATE ZIP
CA
PHONE FAX
EMAIL OCCUPANT'S BUS. LIC. No.
DELIVERY OPTIONS
0 PICK UP: u CONTACT (Listed above) o OCCUPANT (Listed above)
o CONTRACTOR (On Pg. 1)
o ASSOCIATED CB#------------
0 MAIL TO: o CONTACT (Listed above) o OCCUPANT (listed above)
[l CONTRACTOR (On Pg. 1) o NO CHANGE IN USE/ NO CONSTRUCTION
D MAIL/ FAX TO OTHER:-----------------o CHANGE OF USE/ NO CONSTRUCTION
_L5 APPLICANT'S SIGNATURE DATE
, :p, ;i0 , = v<'"'\
: ·. PERMIT INSPECJION HISto,v REPOR:tt,,cBR%0:'.18-0277) ' '
Perinit Type: BLDG-Residential Application Date: 02/02/2018 Owner:
Work Class: Patio Issue Date: 03/01/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 10/22/2018 Address:
IVR Number: 9304
Scheduled
Date
Actual
Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
04/23/2018 04/23/2018
06/07/2018 06/07/2018
June 07, 2018
BLDG-18 Exterior
Lath/Drywall
055760-2018
BLDG-Final
Inspection
Checklist Item
BLDG-Building Deficiency
060325-2018
Checklist ltom
BLDG-Building Deficiency
BLDG-Plumbing Final
BLOG-Mechanical Final
BLDG-Structural Final
BLOG-Electrical Final
Passed Paul Burnette
COMMENTS
Passed Paul Burnette
COMMENTS
TRUST YGLESIA LIVING TRUST A
09-21-04
CARLSBAD TCT#90-31 AREA 28
UNIT#02
1338 Alcyon Ct
Carlsbad, CA 92011-4880
Re inspection Complete
Complete
Passed
Yes
Complete
Passed
Yes
Yes
Yes
Yes
Yes
Page2of2
"7 0 ,
. ~ vRERNIIT INSPEG:TION 1-tlSTORY REPORT (GBR2018-0277) ,,,0 ' ' '
Permit Type: BLDG-Residential Application Date: 02/02/2018 Owner: TRUST YGLESIA LIVING TRUST A
09-21-04
Work Class· Patio Issue Date: 03/01/2018 Subdivision: CARLSBAD TCT#90-31 AREA 28
UNIT#02
Status: Closed -Fina led Expiration Date: 10/22/2018 Address: 1338 Alcyon Ct
Carlsbad, CA 92011-4880
IVR Number: 9304
Scheduled Actual Inspection No. Inspection Status Re inspection Complete Date Start Date Inspection Type Primary Inspector
03/08/2018 BLDG-11 051317-2018 Passed Paul Burnette Complete
Foundation/Ftg/Pier
s (Rebar)
Checkhst Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-13 Shear 055434-2018 Passed Paul Burnette Complete
Panels/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-15 055435-2018 Passed Paul Burnette Complete
RooflReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
03/07/2018 03/07/2018 BLDG-11 050850-2018 Fa tied Paul Burnette Reinspection Complete
Foundatlon/Ftg/Pier
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
04/12/2018 04112/2018 BLDG-84 Rough 054786-2018 Failed Paul Burnette Relnspection Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG~34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
04/1612018 04116/2018 BLDG-84 Rough 055073-2018 Passed Paul Burnette Complete
Combo(14,24,34,44)
Checklist lto1n COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
June 07, 2018 Page 1 of2
/. EsG1I
DATE: February 27, 2018
JURISDICTION: Carlsbad
a APPLICANT
_9--JURIS.
PLAN CHECK#.: CBR2018-0277 SET II
PROJECT ADDRESS: 1338 Alcyon Ct.
PROJECT NAME: Yglesia Cabana
D
D
D
D
D
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Stephen Ray
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: ,Stept1e11 Ra 1 Telephone #: 619-361-1331
Date contacted: -(b~ r.:\) Email: jr@raydev.net
Mail Telephone Fax ~:on \_ ./
REMARKS: Slip sheets were provided, please update all other setsQl~ew sheets: A 1.1, A2.1,
A3.1 and S1. Jv
By: Kat Frankowski
EsGil
2/21/2018
Enclosures:
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
,
DATE: February 13, 2018
JURISDICTION: Carlsbad
PLAN CHECK#.: CBR2018-0277
PROJECT ADDRESS: 1338 Alcyon Ct.
PROJECT NAME: Yglesia Cabana
V EsG1I
i
SET: I
~PPLICANT ? JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Stephen Ray
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Stephen Ray Telephone#: 619-361-1331
;rate cont.9cted:v1 r~
~ail ..fe1ephone Fax
D REMARKS:
By: Kat Frankowski
EsGil
(by: ~ Email: jr@raydev.net
In Person
Enclosures:
2/6/2018
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
'
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: CBR2018-0277
PROJECT ADDRESS: 1338 Alcyon Ct.
FLOOR AREA: 400
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 2/2/2018
DATE INITIAL PLAN REVIEW
COMPLETED: February 13, 2018
FOREWORD (PLEASE READ):
JURISDICTION: Carlsbad
STORIES: 1
HEIGHT: 10
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 2/6/2018
PLAN REVIEWER: Kat Frankowski
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC,
2015 UPC, 2015 UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one
of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-
2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and
Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake
Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of
plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City
Planning, Engineering and Fire Departments until review by EsGil is complete.
• PLANS
1. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
2. On sheet A3.1 sections A and B are mislabeled, please address.
• ROOFS/DECKS/BALCONIES
3. Note on the plans: "Attic ventilation openings shall be covered with
corrosion-resistant metal mesh with 1/16" minimum to Y." maximum openings.
Section R806.1.
• FOUNDATION REQUIREMENTS
4. Note on plans that surface water will drain away from building and show drainage
pattern. The grade shall fall a minimum of 6" within the first 10 feet. Section
R401.3.
• STRUCTURAL
5. Beams shown on plans are extremely undersized, please hire the services of a
structural engineer and provide calculations.
• MECHANICAL
6. Specify on the plans the following information for the fireplace(s):
a) Manufacturer's name/model number and ICC approval number, or equal.
b) Show the height of the factory-built chimney above the roof and the
horizontal clearances per listing approval. Chimneys shall extend at least
3' above the highest point where it passes through a roof and at least 2'
higher than any portion of a building within a horizontal distance of 10
feet. CMC Section 802.5.4.
c) Note on the plans that approved spark arrestors shall be installed on all
chimneys. CRC Section R1003.9.
d) Decorative shrouds shall not be installed at the termination of chimneys
for factory-built fireplaces, except where such shrouds are listed and
labeled for use with the specific system and installed in accordance with
the manufacturer's installation instructions. Section CRC 1004. 3.
• ELECTRICAL
7. Include on the plans the following specifications for electrical devices installed in
dwellings: CEC Article 210 & 406
a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all
receptacles in a dwelling).
b) Weather resistant type for receptacles installed in damp or wet locations
(outside).
c) Arc-fault protection for all outlets (not just receptacles) located in rooms
described in NEC 210.12(A): Kitchens, laundry areas, family, living,
bedrooms, dining, halls, etc.
d) GFCI protected outlets for locations described in NEC 210.8(A): Laundry
areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors,
within 6' of a sink, etc.
• MISCELLANEOUS
8. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
9. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes D No D
10. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Kat Frankowski at EsGil. Thank you.
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Kat Frankowski
BUILDING ADDRESS: 1338 Alcyon Ct.
BUILDING OCCUPANCY:
BUILDING
PORTION
Cabana
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb
1997 UBC Building Permit Fee
1997 UBC Plan Check Fee
Type of Review:
D Repetitive Fee
• Repeats
Comments:
AREA Valuation
( Sq. Ft.) Multiplier
400
By Ordinance
...
Complete Review
D Other
0 Hourly
EsGil Fee
PLAN CHECK#.: CBR2018-0277
DATE: February 13, 2018
Reg. VALUE ($)
Mod.
57,970
57,970
$436.541
$283.751
D Structural Only
>-----I Hr. @ • $248.83J
Sheet 1 of 1
DATE: 2/09/18
PLANNING OIVl~ON
BUILDING PLAN CHECK
REVIEW CHECKLIST
P-28
Developmet;t Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.eov
PROJECT NAME: CABANA PROJECT ID: CBR2018-0277
PLAN CHECK NO: 1 SET#: 1 ADDRESS: 1338 ALCYON COURT APN: 2157810900
D This plan check review is complete and has been APPROVED by the
Division.
By: HECTOR SALGADO
A Final Inspection by the PLANNING Division is required D Yes 12<;] No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
~ This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to: JR@RAYDEV.NET
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING ENGINEERING FIRE PREVENTION
76~02-4610 76~02-2750 76~02-4665
~ Hector Satgad~
760-602-;4624
HectQr. ca.goy
D Gina Ruiz
76().602-4675
Gina.Ruiz@carlsbadca.gov
D
Remarks:
I
/.:~ -~ t"' , .. \,, ...
PLANNING DIV'510N
BUILDING PLAN CHECK
REVIEW CHECKLIST
P-28
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carJsbadca.eov
~ CITY 01
CARLSBAD
REVIEW#:
1 2 3
t8l DD
t8l DD
t8l DD
t8l DD
t8l DD
Plan Check No. CBR2018-0277 Address 1338 ALCYON CT Date 2/9/18 Review# 1
Planner HECTOR SALGADO Phone 1760) 602-4624
APN: 2157810900
Type of Project & Use: __ Net Project Density: DU/AC
Zoning: P-C General Plan: R-4 Facilities Management Zone: 19
CFD (in/out) #_Date of participation: __ Remaining net dev acres: __
(For non-residential development: Type of land use created by this permit: __ )
Legend: ~ Item Complete O Item Incomplete -Needs your action
Environmental Review Required: YES O NO t8J TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES O NO t8J TYPE __
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval: __
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES D NO t8l
CA Coastal Commission Authority? YES O NO~
If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San
Diego, CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Habitat Management Plan
Data Entry Completed? YES O NO cg]
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and
assess fees in Energov
lnclusionary Housing Fee required: YES D NO t8l
{Effective date of lnclusionary Housing Ordinance-May 21, 1993.)
Data Entry Completed? YES D NO D
[8J DD
Site Plan:
[8JD0
ODD
DOD
[8J DD
DOD
For construction of inclusionary units, email notification provided to HNS?: YES D NO D
(Email Susan Steinkemp in HNS with project number and contact info)
Housing Tracking Form (form P-20) completed: YES D NO D NIA [8J
Proviqe a M!Y qime11sional site pl&n drawn !o scale. Show: North arrow, property lines,
easements, existing and proposed structures, streets, existing street improvements, right-of-
way width, dimensional setbacks and existing topographical lines (including all side and rear
yard slopes). Provide legal description of property and assessor's parcel number.
City Council Policy 44 -Neighborhood Architectural Design Guidelines
1. Applicability: YES D NO D
2. Project complies: YES D NOD
Zoning:
1. Setbacks: NEED LOT WIDTH TO CONFIRM SET BACKS: SEE NOTE BELOW
Front
Interior Side:
Street Side:
Rear:
Top of slope:
Required __ Shown __
Required __ Shown __
Required ___ Shown __
Required __ Shown __
Required __ Shown __
2. Accessory structure setbacks: NEED LOT WIDTH TO CONFIRM SET BACKS: SEE
NOTE BELOW
front
Interior Side:
Street Side:
Rear:
Structure separation:
Required __ Shown __
Required __ Shown __
Required __ Shown __
Required __ Shown __
Required __ Shown __
3. Lot Coverage: Required __ Shown __
4. Height: Required __ Shown __
5. Parking: Spaces Required __ Shown __
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required __ Shown __
Additional Comments PLIAN CHECK-#1
#1. PLEASE PROVIDE LOT WIDTH TO CONFIRM SIDE YARD SETBACK (SIDE YARD
SETBACKS ARE EQUAL TO 10% OF LOT WIDTH).
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE
P-28 Page 3 of3 07/11
{cicyof
Carlsbad
CIRCUIT CARD
B-36
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
THIS CARD MUST BE FILLED OUT AND AVAJLABLE AT THE SERVICE T-r UJPMENT FOR THE ROUOH INSPEcnON
Address: 12->~9 ALC-.'lo~ (:£Ju. i,e...-Penni! Number:
Owner: I Phone: Area In Sq. Ft.
Contractor: c__,o...:, ~: ""' '1 'Si<, ;r,1 Phone: '
PANEL: .)g..._t,, ..... ~ I<> QWO A.I.C. \'2.cl'?~o VOLTS I Iii <. WIRE
CKT BKR WIRE MISC REC REC LTG MISC WIRE BKR CKT LOCATION LOCATION SIZE SIZE TYPE SIZE TYPB SIZE
~~"' 1 I") l't ~"" ", 6 2
,-,,, n • . 3 ......,.,. l '2... 1..\nf\ L., 4
5 6
7 8
9. 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 I 40
41 42
lz_.1(. 9-oo
AMP9usE o MLO Computed Load AMPS MAIN:0
BUS: 'l..,.:>>· See calculation Worlcsheet on back AMP Branch circuits required: Service entrance or feeder conductors:
A) Size: No. B) Typa: D CU O AL A) Lighting Circuits 220 -3(b), 4(d)
B) Two Small Appliance Circuits 210-11(e)
C) Insulation: D) Conduit Size: ___ C) Laundry Circuit 220-16(b)
Service ground/bond:
B) Typa: 0 cu D AL
0) Central Heating Equipment 422-12
A) Size: No. E) Bathroom 210-52(d)
C) Clamp location(s):
DUFER 250-50(c) Remarks:
D Water Pipe 250-104
D Ground Rod 250-52
D
GFCl locations 210-8, 680-70: I certify that all terminations have bean torqued in accordance with manufacturer's
D Bathroom(s) D Kitchen instructions and that the work shown on this circuit card represents the full extent of
D Garage(s) DHydromassage Tub the worl< performed under this permit. fc/ Outdoors 0 DOwner
A Protected Clrc. 210 12 D Contractor_............/ -.
D Bedroom(s) OStgne--'""'/d --Date -· ''8 '/ -·-.
B-36 Page 1 of 2 Rev. 03/09
1.
2.
3.
4.
5.
SINGLE FAMILY DWELLING
ELECTRICAL SERVICE LOAD CALCULATION
As an alternative method, the STANDARD METHOD
found In ARTICLE 220 of the National Electric Code, may be used
GENERAL LIGHTING LOADS
Dwelling sq. ft. x 3 VA= 220-3(a) VA
Small appliance loads-220-16(a) 1500 VA x circuits= VA
Laundry load-220-16(b) 150_0 VA x circuits= VA
General Lighting Total
COOKING EQUIPMENT LOADS -Nameplate Value
Range VA= VA
Cooktop VA= VA
Oven (s) VA= VA
Cooking Equipment Total
ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum)
Dryer VA= Dryer Total
FIXED APPLIANCE LOADS 230-30 (b) (3)
Dishwasher = VA
Disposal= VA
Compactor= VA
Water Heater = VA
Hydromassage Bathtub = VA
Microwave Oven = VA
Built-in Vacuum = VA
= VA
Fixed Appliance Total
OPTIONAL SUBTOTAL (Add all of the above totals)
6. APPLYING DEMAND FACTORS -TABLE 220-30
First 10,000 VA x 100% = 10,000VA
Optional Subtotal (from line 5) ( Remaining ___ VA x 40%=
7. HEATING OR AC LOAD -TABLE 220-30
Larger of the Heating or AC Load =
8. OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7) =
9. MINIMUM SERVICE SIZE = Optional Loads Total =
240Volt
____ VA
____ VA
____ VA
____ Ampere
(Please put total on front of card under Computed Load)
VA
VA
VA
VA
VA