Loading...
HomeMy WebLinkAbout1338 Alcyon Ct; ; CBR2018-0277; Permit(city of Carlsbad Residential Permit Print Date: 06/07/2018 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 1338 Alcyon Ct BLDG-Residential 2157810900 $57,969.73 Work Class: Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Description: YGLESIA: 400 SF DETACHED CABANA W/ FIREPLACE Applicant: Owner: Patio STEPHEN RAY 4041 Bonita Rd, Ste B Bonita, CA 91902-1350 619-361-1331 TRUSTYGLESIA LIVING TRUST A 09-21-04 1338 Alcyon Ct BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) CARLSBAD, CA 92011 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL 581473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTJON-RESIDENTIAL Total Fees: $883.99 Total Payments To Date: $883.99 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Permit No: CBR2018-0277 Closed -Finaled 02/02/2018 03/01/2018 PB urn 6/7/2018 2:34:50PM $0.00 $441.44 $3D9.0l $43.00 $80.00 $3.DO $7.54 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-6D2-8560 f I www.carlsbadca.gov EHE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: D PLANNING D ENGINEERING 'j , ~BUILDING OFIRE 0HEALTH 0HAZMAT/APCD af • f Building Permit Application Plan Check No. Est. Value -021'1 ~ Clty O 1635 Faraday Ave., Carlsbad, CA 92008 Carlsb ".l,d Ph: 760-602-2719 Fax: 760-602-8558 U email: building@carlsbadca.gov www.carlsbadca.gov Plan Ck. Deposit Date' cq -00 con SUITE#/SPACE#/UNIT# JOB ADDRESS \ ?,8 CT/PROJECT# PHASE# # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE acc. GROUP APPLICANT NAME Primary Contact ADDRESS CITY PHONE " EMAIL ,, ,Jal t....1 ,, STATE QZIP ,...._ \( FAX 1..1.. ff , , DESIGN PR0FESS10N0 -\e_ \ti\ ~ ------ ADDRESS-'i> _:__~--~~--- l-'Ql-j / ~\~ ~"' .. ~~------ CITY '16 OC'\ ..,-e>--STATEC..A PHONG\"'\_ ?Jct-i?,3( ['_AX __ _ EMAIL ;:;\ ~-~ J:r ey'<Cvv\cb.N_:_._Y',.Q_::i....:-;c*~---~ STATE UC.# PATIOS (SF) DECKS (SF) FIREPLACE YES0 PROPERTY OWNER ADDRESS CITY STATE ZIP PHONE FAX EMAIL CONTRACTOR ·~~(Mt J, I , " . 13~.h. ( _____ _ ADDRESS / _ ~ .., cl / '.)c!_;, ~ [..., s ,r, f '-c-,rv--p-.. -"·---. -S-TA_T_E_~--ZIP/, '/ ./ "fu '/Jl\, PHO'/;~';-:~ 7 ''/-~CC!¥ FAX ~~ EMAIL /(.' G) {'c ,)_id(/-", Jf· 5., 7~ --- srAre LIR:# CLASS ,). CITY BU LIC # '!' C13'f V (Sec. 7031.5 Business and P.rofessions Code: Any City or County which requires a permit to.construct. alter, improve, demolish or repair any structure, prior to its issuan a r ires the applicant for such per.mil to file a signed statement that he is licensed pursuant to the prov1s1ons of the Contractor's License LawJChapter 9, comme_nd1ng with Section 7000 of Division 3 of th Business and Professions Code) or fuat he is exempt therefrom, and the basis for the alleged exemption. Any v1otat1on of Section 031.5 by any applicant for a permit subJects the applicant to a civil penalty of not more than five hundred dollars {$500)). -"-W' - WORKERS' COMPENSATION --, , ,z, ", Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' comiensauon, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co.~_( . .,...,, -k li,_j..,ir ·, '\( (_ { ~' - ----Policy No. { j r 5 D I .A 2 C, 1 . Expiration Date .;J) /t) I 10,1 This section need not be completed if the permit is for one hundred dollars ($100) or less. 0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING: Failure to secure woril:ers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as P. ij for Section 3706 of the labor code, interest and attorney's fees. fE5 CONTRACTOR SIGNATURE I hereby affirm that I am exempt from Contractor's License Law for the following reason: D D D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project {Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section __ , ___ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0Yes 0No 2. I (have I have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number) 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work): fE5 PROPERTY OWNER SIGNATURE 0AGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes O No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes O No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes O No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certifythatl have read the application and state that the above lnfmmation lsrorrectand that the Information on the plans is acx:urate. I agree to comply with all City ordinances and State laws relating to buildingronstruction. I hereby aulhOfize representabve of the City of Cartsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS ANO EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CrTY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA: An OSHA permit is required for excavations (1oJe( 5'0' deep and demolitioo or construction of structures over 3 stories in height. EXPIRATION: Every pennit issued by the Buikling Official under the provisions of this Code shall expire by limitation and become null and void if the building or'Mlrk authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work aulhori such permit is suspen or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). Af5 APPLICANT'S SIGNATURE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY Carlsbad STATE ZIP CA PHONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS 0 PICK UP: u CONTACT (Listed above) o OCCUPANT (Listed above) o CONTRACTOR (On Pg. 1) o ASSOCIATED CB#------------ 0 MAIL TO: o CONTACT (Listed above) o OCCUPANT (listed above) [l CONTRACTOR (On Pg. 1) o NO CHANGE IN USE/ NO CONSTRUCTION D MAIL/ FAX TO OTHER:-----------------o CHANGE OF USE/ NO CONSTRUCTION _L5 APPLICANT'S SIGNATURE DATE , :p, ;i0 , = v<'"'\ : ·. PERMIT INSPECJION HISto,v REPOR:tt,,cBR%0:'.18-0277) ' ' Perinit Type: BLDG-Residential Application Date: 02/02/2018 Owner: Work Class: Patio Issue Date: 03/01/2018 Subdivision: Status: Closed -Finaled Expiration Date: 10/22/2018 Address: IVR Number: 9304 Scheduled Date Actual Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 04/23/2018 04/23/2018 06/07/2018 06/07/2018 June 07, 2018 BLDG-18 Exterior Lath/Drywall 055760-2018 BLDG-Final Inspection Checklist Item BLDG-Building Deficiency 060325-2018 Checklist ltom BLDG-Building Deficiency BLDG-Plumbing Final BLOG-Mechanical Final BLDG-Structural Final BLOG-Electrical Final Passed Paul Burnette COMMENTS Passed Paul Burnette COMMENTS TRUST YGLESIA LIVING TRUST A 09-21-04 CARLSBAD TCT#90-31 AREA 28 UNIT#02 1338 Alcyon Ct Carlsbad, CA 92011-4880 Re inspection Complete Complete Passed Yes Complete Passed Yes Yes Yes Yes Yes Page2of2 "7 0 , . ~ vRERNIIT INSPEG:TION 1-tlSTORY REPORT (GBR2018-0277) ,,,0 ' ' ' Permit Type: BLDG-Residential Application Date: 02/02/2018 Owner: TRUST YGLESIA LIVING TRUST A 09-21-04 Work Class· Patio Issue Date: 03/01/2018 Subdivision: CARLSBAD TCT#90-31 AREA 28 UNIT#02 Status: Closed -Fina led Expiration Date: 10/22/2018 Address: 1338 Alcyon Ct Carlsbad, CA 92011-4880 IVR Number: 9304 Scheduled Actual Inspection No. Inspection Status Re inspection Complete Date Start Date Inspection Type Primary Inspector 03/08/2018 BLDG-11 051317-2018 Passed Paul Burnette Complete Foundation/Ftg/Pier s (Rebar) Checkhst Item COMMENTS Passed BLDG-Building Deficiency No BLDG-13 Shear 055434-2018 Passed Paul Burnette Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-15 055435-2018 Passed Paul Burnette Complete RooflReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 03/07/2018 03/07/2018 BLDG-11 050850-2018 Fa tied Paul Burnette Reinspection Complete Foundatlon/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 04/12/2018 04112/2018 BLDG-84 Rough 054786-2018 Failed Paul Burnette Relnspection Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG~34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 04/1612018 04116/2018 BLDG-84 Rough 055073-2018 Passed Paul Burnette Complete Combo(14,24,34,44) Checklist lto1n COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers June 07, 2018 Page 1 of2 /. EsG1I DATE: February 27, 2018 JURISDICTION: Carlsbad a APPLICANT _9--JURIS. PLAN CHECK#.: CBR2018-0277 SET II PROJECT ADDRESS: 1338 Alcyon Ct. PROJECT NAME: Yglesia Cabana D D D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Stephen Ray EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: ,Stept1e11 Ra 1 Telephone #: 619-361-1331 Date contacted: -(b~ r.:\) Email: jr@raydev.net Mail Telephone Fax ~:on \_ ./ REMARKS: Slip sheets were provided, please update all other setsQl~ew sheets: A 1.1, A2.1, A3.1 and S1. Jv By: Kat Frankowski EsGil 2/21/2018 Enclosures: 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 , DATE: February 13, 2018 JURISDICTION: Carlsbad PLAN CHECK#.: CBR2018-0277 PROJECT ADDRESS: 1338 Alcyon Ct. PROJECT NAME: Yglesia Cabana V EsG1I i SET: I ~PPLICANT ? JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Stephen Ray EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Stephen Ray Telephone#: 619-361-1331 ;rate cont.9cted:v1 r~ ~ail ..fe1ephone Fax D REMARKS: By: Kat Frankowski EsGil (by: ~ Email: jr@raydev.net In Person Enclosures: 2/6/2018 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ' PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR2018-0277 PROJECT ADDRESS: 1338 Alcyon Ct. FLOOR AREA: 400 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 2/2/2018 DATE INITIAL PLAN REVIEW COMPLETED: February 13, 2018 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad STORIES: 1 HEIGHT: 10 DATE PLANS RECEIVED BY ESGIL CORPORATION: 2/6/2018 PLAN REVIEWER: Kat Frankowski This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. • PLANS 1. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 2. On sheet A3.1 sections A and B are mislabeled, please address. • ROOFS/DECKS/BALCONIES 3. Note on the plans: "Attic ventilation openings shall be covered with corrosion-resistant metal mesh with 1/16" minimum to Y." maximum openings. Section R806.1. • FOUNDATION REQUIREMENTS 4. Note on plans that surface water will drain away from building and show drainage pattern. The grade shall fall a minimum of 6" within the first 10 feet. Section R401.3. • STRUCTURAL 5. Beams shown on plans are extremely undersized, please hire the services of a structural engineer and provide calculations. • MECHANICAL 6. Specify on the plans the following information for the fireplace(s): a) Manufacturer's name/model number and ICC approval number, or equal. b) Show the height of the factory-built chimney above the roof and the horizontal clearances per listing approval. Chimneys shall extend at least 3' above the highest point where it passes through a roof and at least 2' higher than any portion of a building within a horizontal distance of 10 feet. CMC Section 802.5.4. c) Note on the plans that approved spark arrestors shall be installed on all chimneys. CRC Section R1003.9. d) Decorative shrouds shall not be installed at the termination of chimneys for factory-built fireplaces, except where such shrouds are listed and labeled for use with the specific system and installed in accordance with the manufacturer's installation instructions. Section CRC 1004. 3. • ELECTRICAL 7. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). b) Weather resistant type for receptacles installed in damp or wet locations (outside). c) Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(A): Kitchens, laundry areas, family, living, bedrooms, dining, halls, etc. d) GFCI protected outlets for locations described in NEC 210.8(A): Laundry areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors, within 6' of a sink, etc. • MISCELLANEOUS 8. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 9. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes D No D 10. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kat Frankowski at EsGil. Thank you. [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Kat Frankowski BUILDING ADDRESS: 1338 Alcyon Ct. BUILDING OCCUPANCY: BUILDING PORTION Cabana Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb 1997 UBC Building Permit Fee 1997 UBC Plan Check Fee Type of Review: D Repetitive Fee • Repeats Comments: AREA Valuation ( Sq. Ft.) Multiplier 400 By Ordinance ... Complete Review D Other 0 Hourly EsGil Fee PLAN CHECK#.: CBR2018-0277 DATE: February 13, 2018 Reg. VALUE ($) Mod. 57,970 57,970 $436.541 $283.751 D Structural Only >-----I Hr. @ • $248.83J Sheet 1 of 1 DATE: 2/09/18 PLANNING OIVl~ON BUILDING PLAN CHECK REVIEW CHECKLIST P-28 Developmet;t Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.eov PROJECT NAME: CABANA PROJECT ID: CBR2018-0277 PLAN CHECK NO: 1 SET#: 1 ADDRESS: 1338 ALCYON COURT APN: 2157810900 D This plan check review is complete and has been APPROVED by the Division. By: HECTOR SALGADO A Final Inspection by the PLANNING Division is required D Yes 12<;] No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. ~ This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: JR@RAYDEV.NET For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 76~02-4610 76~02-2750 76~02-4665 ~ Hector Satgad~ 760-602-;4624 HectQr. ca.goy D Gina Ruiz 76().602-4675 Gina.Ruiz@carlsbadca.gov D Remarks: I /.:~ -~ t"' , .. \,, ... PLANNING DIV'510N BUILDING PLAN CHECK REVIEW CHECKLIST P-28 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carJsbadca.eov ~ CITY 01 CARLSBAD REVIEW#: 1 2 3 t8l DD t8l DD t8l DD t8l DD t8l DD Plan Check No. CBR2018-0277 Address 1338 ALCYON CT Date 2/9/18 Review# 1 Planner HECTOR SALGADO Phone 1760) 602-4624 APN: 2157810900 Type of Project & Use: __ Net Project Density: DU/AC Zoning: P-C General Plan: R-4 Facilities Management Zone: 19 CFD (in/out) #_Date of participation: __ Remaining net dev acres: __ (For non-residential development: Type of land use created by this permit: __ ) Legend: ~ Item Complete O Item Incomplete -Needs your action Environmental Review Required: YES O NO t8J TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES O NO t8J TYPE __ APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: __ Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES D NO t8l CA Coastal Commission Authority? YES O NO~ If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Habitat Management Plan Data Entry Completed? YES O NO cg] If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Energov lnclusionary Housing Fee required: YES D NO t8l {Effective date of lnclusionary Housing Ordinance-May 21, 1993.) Data Entry Completed? YES D NO D [8J DD Site Plan: [8JD0 ODD DOD [8J DD DOD For construction of inclusionary units, email notification provided to HNS?: YES D NO D (Email Susan Steinkemp in HNS with project number and contact info) Housing Tracking Form (form P-20) completed: YES D NO D NIA [8J Proviqe a M!Y qime11sional site pl&n drawn !o scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. City Council Policy 44 -Neighborhood Architectural Design Guidelines 1. Applicability: YES D NO D 2. Project complies: YES D NOD Zoning: 1. Setbacks: NEED LOT WIDTH TO CONFIRM SET BACKS: SEE NOTE BELOW Front Interior Side: Street Side: Rear: Top of slope: Required __ Shown __ Required __ Shown __ Required ___ Shown __ Required __ Shown __ Required __ Shown __ 2. Accessory structure setbacks: NEED LOT WIDTH TO CONFIRM SET BACKS: SEE NOTE BELOW front Interior Side: Street Side: Rear: Structure separation: Required __ Shown __ Required __ Shown __ Required __ Shown __ Required __ Shown __ Required __ Shown __ 3. Lot Coverage: Required __ Shown __ 4. Height: Required __ Shown __ 5. Parking: Spaces Required __ Shown __ (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required __ Shown __ Additional Comments PLIAN CHECK-#1 #1. PLEASE PROVIDE LOT WIDTH TO CONFIRM SIDE YARD SETBACK (SIDE YARD SETBACKS ARE EQUAL TO 10% OF LOT WIDTH). OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE P-28 Page 3 of3 07/11 {cicyof Carlsbad CIRCUIT CARD B-36 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov THIS CARD MUST BE FILLED OUT AND AVAJLABLE AT THE SERVICE T-r UJPMENT FOR THE ROUOH INSPEcnON Address: 12->~9 ALC-.'lo~ (:£Ju. i,e...-Penni! Number: Owner: I Phone: Area In Sq. Ft. Contractor: c__,o...:, ~: ""' '1 'Si<, ;r,1 Phone: ' PANEL: .)g..._t,, ..... ~ I<> QWO A.I.C. \'2.cl'?~o VOLTS I Iii <. WIRE CKT BKR WIRE MISC REC REC LTG MISC WIRE BKR CKT LOCATION LOCATION SIZE SIZE TYPE SIZE TYPB SIZE ~~"' 1 I") l't ~"" ", 6 2 ,-,,, n • . 3 ......,.,. l '2... 1..\nf\ L., 4 5 6 7 8 9. 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 I 40 41 42 lz_.1(. 9-oo AMP9usE o MLO Computed Load AMPS MAIN:0 BUS: 'l..,.:>>· See calculation Worlcsheet on back AMP Branch circuits required: Service entrance or feeder conductors: A) Size: No. B) Typa: D CU O AL A) Lighting Circuits 220 -3(b), 4(d) B) Two Small Appliance Circuits 210-11(e) C) Insulation: D) Conduit Size: ___ C) Laundry Circuit 220-16(b) Service ground/bond: B) Typa: 0 cu D AL 0) Central Heating Equipment 422-12 A) Size: No. E) Bathroom 210-52(d) C) Clamp location(s): DUFER 250-50(c) Remarks: D Water Pipe 250-104 D Ground Rod 250-52 D GFCl locations 210-8, 680-70: I certify that all terminations have bean torqued in accordance with manufacturer's D Bathroom(s) D Kitchen instructions and that the work shown on this circuit card represents the full extent of D Garage(s) DHydromassage Tub the worl< performed under this permit. fc/ Outdoors 0 DOwner A Protected Clrc. 210 12 D Contractor_............/ -. D Bedroom(s) OStgne--'""'/d --Date -· ''8 '/ -·-. B-36 Page 1 of 2 Rev. 03/09 1. 2. 3. 4. 5. SINGLE FAMILY DWELLING ELECTRICAL SERVICE LOAD CALCULATION As an alternative method, the STANDARD METHOD found In ARTICLE 220 of the National Electric Code, may be used GENERAL LIGHTING LOADS Dwelling sq. ft. x 3 VA= 220-3(a) VA Small appliance loads-220-16(a) 1500 VA x circuits= VA Laundry load-220-16(b) 150_0 VA x circuits= VA General Lighting Total COOKING EQUIPMENT LOADS -Nameplate Value Range VA= VA Cooktop VA= VA Oven (s) VA= VA Cooking Equipment Total ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum) Dryer VA= Dryer Total FIXED APPLIANCE LOADS 230-30 (b) (3) Dishwasher = VA Disposal= VA Compactor= VA Water Heater = VA Hydromassage Bathtub = VA Microwave Oven = VA Built-in Vacuum = VA = VA Fixed Appliance Total OPTIONAL SUBTOTAL (Add all of the above totals) 6. APPLYING DEMAND FACTORS -TABLE 220-30 First 10,000 VA x 100% = 10,000VA Optional Subtotal (from line 5) ( Remaining ___ VA x 40%= 7. HEATING OR AC LOAD -TABLE 220-30 Larger of the Heating or AC Load = 8. OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7) = 9. MINIMUM SERVICE SIZE = Optional Loads Total = 240Volt ____ VA ____ VA ____ VA ____ Ampere (Please put total on front of card under Computed Load) VA VA VA VA VA