Loading...
HomeMy WebLinkAbout1339 ALCYON CT; ; CB063542; Permit01-25-2007 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No: CB063542 Building Inspection Request Line (760) 602-2725 1339ALCYONCTCBAD RESDNTL Sub Type: RAD 2157810800 Lot#: 0 $18,688.00 Construction Type: VN Reference #: 0 Structure Type: 0 . Bathrooms: 0 SHAFRAN: 119 SF NOOK/278 SF BALCONY/16 FT FIREPLACE (OUTDOOR)(CITY) Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Orig PC#: Plan Check*: ISSUED 12/19/2006 JMA 01/25/2007 01/25/2007 Applicant: ECS CONSTRUCTION Owner: SHAFRAN AVAL TR&SHAFRAN CHRISTINA M TR 1880 BURNT MAPLE WY VISTA CA 92083 760 727-0063 1339ALCYONCT CARLSBAD CA 92011 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $168.99 Meter Size $0.00 Add'l Reel. Water Con. Fee $109.84 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $1.87 PFF (3105540) $0.00 PFF (4305540) $0.00 License Tax (3104193) $0.00 License Tax (4304193) $0.00 Traffic Impact Fee (3105541) $0.00 ' Traffic Impact Fee (4305541) $0.00 Sidewalk Fee $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $89.00 Housing Impact Fee $0.00 Housing InLieu Fee $0.00 Housing Credit Fee Master Drainage Fee $0.00 Sewer Fee $0.00 . Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $20.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $389.70 Total Fees:$389.70 Total Payments To Date:$389.70 Balance Due:$0.00 BUf!JUNG PLANS -YlJN STORAGE ATTACHED Inspector:Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 1. PROJECT INFORMATION- 'S*? FOR OFFICE USE ONLY PLAN CHECK EST. VAL. Plan Ck. Deposit Validated B Date By \\?\<\ Address (include Bldg/Suite #)Business Name (at this address) Legal Description Lot No.Subdivision Name/Number Unit No.Phase No.Total # of units Assessor's Parcel #Existing Use Proposed Use orry Description of Work - 2-7£ $ CONTACT PERSON Of different?from applicant) SQ. FT.#of Stories # of Bedrooms # of Bathrooms Name Address City .3. .. :APPUCANt' Q3't5ontractQr Q Agent for Contractor Q Owner Q Agent for Owner State/Zip Telephone Fax* Name 4. PROPERTY OWNER Address City State/Zip Telephone # Name Address City State/Zip Telephone # 5. CONTRACTOR - COMPANY NAME (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars I$5001). "fee-TV? Name State License # Address License Class City State/Zip City Business License # I '2- Telephone # Designer Name Address City State/Zip Telephone State License tt ____^^_ 6, WQRKERS'COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: l~l I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the,work for which this permit is issued. 01 nave and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company ^^J^-C' pt-JAl £> Policy No. / /yO _)")~L- Expiration Date |f "i "P / (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100) OR LESS) Q CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars <-*inn nm»-in addition tn the ro«t nf ft!mpon«atinn damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE ^s^—^^^-^^--^^^-^;^ DATE /Z-" /^"PC- 7. OWNER-BUILDER DECLARATION _ I hereby affirm that I am exempt from the Contractor's License Law for the following reason: n I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). n I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). C] I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. O YES [UNO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR/VOW-ff£S/D£/VrW£ BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? d YES [U NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? fj YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. «7CO>!STRUCf ION LENDING AGENCY ',."'." . ~r '. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS 9. APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commencedfojua period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For: 09/20/2007 Permit* CB063542 Title: SHAFRAN: 119 SF NOOK/278 SF Description: BALCONY/16 FT FIREPLACE (OUTDOOR)(CITY) Type:RESDNTL Sub Type: RAD Job Address: 1339 ALCYON CT Suite: Lot: 0 Location: APPLICANT E C S CONSTRUCTION Owner: SHAFRAN AYAL TR&SHAFRAN CHRISTINA M TR Remarks: Inspector Assignment: JM Phone: 7606888951 Inspector: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By: ERIC Entered By: CHRISTINE Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date Description 03/23/2007 17 Interior Lath/Drywall 03/23/2007 18 Exterior Lath/Drywall 03/21/2007 16 Insulation 03/20/2007 14 Frame/Steel/Bolting/Welding 03/20/2007 18 Exterior Lath/Drywall 03/14/2007 13 Shear Panels/HD's 03/14/2007 14 Frame/Steel/Bolting/Welding 03/14/2007 15 Roof/Reroof 03/14/2007 34 Rough Electric 02/13/2007 11 Ftg/Foundation/Piers Act AP AP AP AP we AP we AP AP AP Insp JM JM JM JM JM JM JM JM JM JM Comments NOOK GATE NOOK 8899 ADD OK EsGil Corporation In (Partnership with government for Quitting Safety DATE: January 18, 2OO7 a APPLICANT a JURIS. JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: CB063542 SET: II PROJECT ADDRESS: 1339 Alcyon Ct. PROJECT NAME: Addition to the Shafran Residence XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: XI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Steve Sanders Enclosures: Esgil Corporation D GA D MB D EJ D PC 1/16/07 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 4- San Diego, California 92123 * (858)560-1468 4 Fax (858) 560-1576 EsGil Corporation In (Partnership with government for Quitting Safety DATE: December 28, 2006 JURISDICTION: Carlsbad Q PLAN REVIEWER Q FILE PLAN CHECK NO.: CB063542 SET: I PROJECT ADDRESS: 1339 Alcyon Ct. PROJECT NAME: Addition to the Shafran Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. IX| The applicant's copy of the check list has been sent to: Carl Stephens 1880 Burnt Maple Way Vista, CA 92081 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Carl Stephens Telephone #: (760) 688-8951 Date contacted:/2/i^/>6?(by^5) Fax #: (760) 727-9763 Mail Telephone v Fax v^ln Person REMARKS:: /V/V\.) By: Steve Sanders Enclosures: Esgil Corporation D GA D MB D EJ D PC 12/21/06 . tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 Carlsbad CBO63542 December 28, 2O06 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: CBO63542 PROJECT ADDRESS: 1339 Alcyon Ct. FLOOR AREA: Addition 119 sq. ft. Deck 278 sq. ft. REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 12/19/06 DATE INITIAL PLAN REVIEW COMPLETED: December 28, 2006 JURISDICTION: Carlsbad STORIES: 2 HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 12/21/06 PLAN REVIEWER: Steve Sanders FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes: 1997 UBC, 2000 UPC, 2000 UMC and 2002 NEC. The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CB063542 December 28, 2006 Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Specify on the Title Sheet of the plans the gross floor area of each element of this project, including dwelling, garage, nook and balcony. Section 106.3.3. 2. Guardrails (Section 509.1): a) Shall be detailed showing adequacy of connections to resist the horizontal force prescribed in Table 16-B. b) Openings between railings shall be less than 4". 3. Provide spiral stairway details, per Section 1003.3.3.8.3: a) Minimum run is 7-1/2 inches measured at a point 12 inches from where the treads are the narrowest. b) Maximum rise is 9-1/2 inches. Maximum clear opening between risers is 4 inches. c) Minimum headroom is 6 feet 6 inches. d) The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail. The plans state the spiral stair to have a diameter of 3'-6". The minimum diameter of a spiral stair is 5'-0". 4. Provide I.C.B.O. Research Report and number for metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation. 5. Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. I Carlsbad CB063542 December 28, 2OO6 Q. Several areas on sheet 3 show a 4x4 supporting the proposed 6x12 deck beam. Sheet 2 shows a 6 x 6 post supporting this beam which is correct. Please revise the posts shown on sheet 3 and provide the appropriate size post cap and post base connections for the 6x6 posts. 7. The roof framing for the nook on sheet 2 shows 2x8 ceiling joists. Section B specifies trusses. Please clarify. If conventional framing is proposed please show the size of the rafters, ridge board etc. 8. Please provide a braced wall panel (shear) schedule on the plans. 9. Show the required ventilation for attics (or enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters). The minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents). Show area required and area provided. Section 1505.3. 10. Show location of attic access with a minimum size of 22"x30", unless the maximum vertical headroom height in the attic is less than 30". Access must be provided to each separated attic area, shall be located in a hallway or other readily accessible location and 30" headroom clearance is required above the opening. Section 1505.1. 11. Provide plans, calculations or worksheets to show compliance with current energy standards adopted October 1, 2005. 12. The regulations require a properly completed and properly signed Form CF-1R (4 pages) to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. 13. Show on the plans compliance with the residential energy lighting requirements (Mandatory requirement): a) All other rooms require any installed fixtures to be high efficacy or be controlled by a manually-on occupancy sensor or dimmer. (Closets under 70 square feet are exempt). b) Outdoor lighting fixtures are required to be high efficacy or controlled by a combination photocontrol/motion sensor. Note: Generally a high efficacy style of fixture is fluorescent complete with electronic ballasts. Regular incandescent, quartz halogen and halogen MR lamps do not comply. Carlsbad CBO63542 December 28, 2006 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Steve Sanders at Esgil Corporation. Thank you. Carlsbad CBO63542 December 28, 2O06 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: CBO63542 PREPARED BY: Steve Sanders DATE: December 28, 2O06 BUILDING ADDRESS: 1339 Alcyon Ct. BUILDING OCCUPANCY: R-3 TYPE OF CONSTRUCTION: VN BUILDING PORTION Addition Deck Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 119 278 cb Valuation Multiplier 121.94 14.41 By Ordinance Reg. Mod. VALUE ($) 14,511 4,006 18,517 $168.99 Plan Check Fee by Ordinance Type of Review: EH Repetitive Fee Repeats Complete Review D Other r-i Hourly Structural Only Hour * Esgil Plan Review Fee Comments: $109.84 $94.63 Sheet 1 of 1 macvalue.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER r.DATE ADDRESS Cour-V- RESIDENTIA Tfil n TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL (<$10,000.00) CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING POOL / SPA RETAINING WALL OTHER PLANNER ENGINEE DATE Q-5U-06, DATE CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1 =============================================================================== Project Title Shafran Home Addition Date .. 01/09/07 21:41:00 Project Address 1337 Alcyon Ct. ******* Carlsbad, CA 92011 . *v7.30* I I Documentation Author... David McKinley ******* | Building Permit # | McKinley Engineering I I 608 Hilo Way I Plan Check-/ Date I Vista, CA 92081 I I 760-414-1992 I Field Check/ Date I Climate Zone 07 Compliance Method MICROPAS7 v7.30 for 2005 Standards by Enercomp, Inc. | MICROPAS7 V7.30 File-SHAFRAN Wth-CTZ07S05 Program-FORM CF-1R I User#-MPl707 User-McKinley Engineering Run-Shafran Home Addition MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = = (kTDV/sf-yr) Design Design Margin = = Space Heating 4.87 5.31 -0.44 = Space Cooling 13.29 13.73 -0.44 = Water Heating 8.21 7.11 1.10 Total 26.37 26.15 0.22 = *** Building complies with Computer Performance *** = GENERAL INFORMATION HERS Verification Not Required Conditioned Floor Area 4917 sf Building Type Single Family Detached Construction Type Existing+Addition+Alteration Vintage Assumptions 1992-1998 Fuel Type NaturalGas Building Front Orientation. Front Facing 0 deg (N) Number of Dwelling Units... 1 Number of Building Stories. 2 Weather Data Type FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 3 Conditioned Volume 60270 cf Slab-On-Grade Area 4521 sf Glazing Percentage 21.9 % of floor area • Average Glazing U-factor... 0.56 Btu/hr-sf-F Average Glazing SHGC 0.62 Average Ceiling Height 12.3 ft ' State Of California S&. CONTRACTORS STATE LICENSE BOARD ,\flair« 665430 E C S CONSTRUCTION 03/31/2007 .j.. License DetailF • '•Page 1 of 2 Californla Home Tuesday, Deceml License Detail Contractor License # 665430 CALIFORNIA CONTRACTORS STATE LICEN DISCLAIMER A license status check provides information taken from the CSLB license data base. Before on this information, you should be aware of the following limitations: • CSLB complaint disclosure is restricted by law (B&P 7124.6). If this entity is subject tc complaint disclosure, a link for complaint disclosure will appear below. Click on the lin button to obtain complaint and/or legal action information. • Per B_&PJ7Q71,117, only construction related civil judgments reported to the CSLB are disclosed. • Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. • Due to workload, there may be relevant information that has not yet been entered ont Board's license data base. * * * Extract Date: 12/19/2006 Business Information * * * E CS CONSTRUCTION 1880 BURNT MAPLE WAY VISTA, CA 92083 Business Phone Number: (760) 727-0063 Entity: Sole Ownership Issue Date: 03/03/1993 Expire Date: 03/31/2007 * * *License Status * * * This license is current and active. All information below should be reviewed. * * *Classifications *•*'* Class W Description GENERAL BMLQiNG CONTRACTOR * * *Bonding Information * * * CONTRACTOR'S BOND: This license filed Contractor's Bond number 1031458 in the air $10,000 with the bonding company http://www2.cslb.ca.gov/CSLB_LIBRARY/License+Detail.asp 12/19/2006 License Detail Page 2 of 2 * * * SURETY COMPANY OF THE PACIFIC. Effective Date: 01/01/2004 Contractor's Bonding History Workers Compensation Information * * * This license has workers compensation insurance with the STATE COMPENSATION INSURANCE FUND Policy Number: 1780392 Effective Date: 04/01/2005 Expire Date: 04/01/2007 Workers Compensation History Personnel List • License NumbeMteguest • Contractor Name Request | Personnel Name Request B Salesperson Request B Salesperson Name Request © 2006 State of California. Conditions of Use Privacy Policy http://www2.cslb.ca.gov/CSLB_LIBRARY/License+Detail.asp 12/19/2006 3-0r 0 ^ 7^ «fed § j ;SW B ' <D O i <J U- u Q g < id COm I < UJo to m a: ^f^- O I o o VJVI $ ^^) 1 N " 2 ro r