HomeMy WebLinkAbout1345 PINE AVE; ; 84-641; Permiti hereby affirm that I have a certificate of consent to self .iesere, or a certificate of Workers'
Compensation Insurance, or a certified copy thereof
(Sec. 3800. Labor Code)
POLICYNO
COMPANY
C] Copy is tiled with the city -
Certified copy is hereby furnisher)
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit
is for one hundred dollars ($100) or less)
0 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California
NOTICE TO APPLICANT It, alter making this Cent
licate of Exemption, you should become subject to the Workers Compensation provisions 01 the Labor
Code, you must forthwith comply with such Provisions or this permit shall be deemed revoked
0 I hereby affirm that there is a construction
lending agency ior the performance, of the work for
which this permit is issued (Sec 3097, Civil Codei
Lender's Name •- -
Lender's Address I
--.
i USE BALL POINT PEN ONLY & PRESS HARD APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.
U hereby affirm that I am licensed under
provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business
and Professions Coda, and my license is in
full force and effect.
Lic No _________________ Class
I hereby affirm that I am exempt from the Contrac-tor's License Law for the following reason (Sec 703t .5
Business and Professions Code: Any city or county which re-quires a permit to construct, alter, improve, demolish, or
repair any structure, prior toils issuance also requires the ap-plicant for such permit to tile a signed statement that he is
licensed pursuant to the provisions of the Contractors
License Law (Chapter 9 commencing with Section 7000 01
Division 3 of the Business and Professions Code) or that is ex-
empt therefrom and the basis for the alleged exemption Any
violation 01 Section 7031.5 by an applicant for a permit sub-
ject/'the applicant tea civil penalty of not more than five hun-
dr dollars ($500)
I, as owner of the property, or my employees with wages
as their sole compensation, will do the work, and the struc-
tare is not intended or uttered for sate (Sec. 7044, Business
...i and Professions Code: The Contractor's License Law does
5 not
apply to an owner of property who builds or improves m thereon and who does such work himself or through his own
employees, provided that such improvements are not intend-
Li cd or offered for sale, If, hawover, lie building or Improve- Z . mert is sold within one year of completion, the owner-builder
will have the burden of proving that he no Id nrinr-
prove for the purpose of sale).
i, as owner of the property, am exclusively contracting with licensed contractors to construct the prefect (Sec. 7044,
Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or im-
proves thereon, and who contracts for each projects with a
contractor(s) license pursuant to the Contractor's License Law).
0 'As a homeowner I am improving my home, and the follow-Ang conditions exist:
The work is being performed prior to sale.
I have lived in my home for twelve months - prior to completion of this work.
I have not claimed this exemption daring the
fast three years.
0 lam exempt under Sec. ___________________ , B & P.C. for this reason
CARLSBAD BUILDING DEPARTMENT AP7JCATION & PERMIT
1200 Elm, Carlsbad, California 92008-1989 (619) 438-5525
JOB ADDRESS AV. ST. RD, NEAREST CROSS ST. DATE BUSINESS LICENSE # VALUATION PERMIT NUMBER
(/7 — \
ZONE gi.1L ,4_I BLOCK SUBDIVISION I ASSS0R PARCEL NO. CONTRACTOR CONTRACTORS P1-40MEv
!Q iF)
,
OWNER'S PHONE
CONTRACTOR'S ADDRESS LICENSE NO, PLAN ID, # BLDG USE CODE
ER'S NAME
t x
,
(1-? rOWNER's
.Fp ?
MAILING ADORES
DESIGNER LICENSE # STANDARD PLAN # BUILDING SO. FOOTAGE
N - DESCRIPTION OF WORK
DESIGNER'S ADDRESS DESIGNER'S PHONE
740
y
- F/P FLR ELEV. I . I NO OCCGP EDU
STORIES
YO NO —
_____
CENSUS TRACT GP LAND USE ' RES UNITS,. I GRADING PERMIT ISSUED REDEVELOPMENT TYPE DCCLOAD FIRESPA JT~SPACE AREA I , CONS
0 N 0 YO NO j f— t) vD N'
\
Not Valid Unless Mac/tine Certified
QTY, PLUMBING PERMIT - ISSUE QTY. MECHANICAL PERMIT - ISSUE 5.... -. SUMMARY/ACCOUNT NUMBER
EACH FIXTURE TRAP INSTALL FURN. DUCTS UP TO 100,000 BTU - BUILDING PERMIT 01-00-00-8220 1
EACH BUILDING SEWER ., . ' ' OVER 100,000 BTU , SIGN PERMIT 01-00-00-8221 -
EACH WATER HEATER AND/OR VENT .573 BOILER/COMPRESSOR UP TO 3 HP PLAN CHECK 01-00-00-8806_ -
EACH GAS SYSTEM 1 TO 4 OUTLETS , BOILER/COMPRESSOR 3.15 HP , TOTAL PLUMBING Qi-e0°126-8222
EACH GAS SYSTEM 5 OR MORE 3 'I. METAL FIREPLACE , 3 - — ELECTRICAL - - 01-00-00-8223 'f-. S
EACH INSTAL., ALTER, REPAIR WATER PIPE . VENT FAN SINGLE DUCT _2 ..- MECHANICAL 01-00-00-8224 / £
EACH VACUUM BREAKER L, .5 MECH EXHAUST HOOD/DUCTS ..-", MOBILEHOME 01-00-00-8225
WATEROFTNER ,, " ' . RELOCATION OF EA FURNACE/HEATER MOBILEHOME PARK (NSF
EACH ROOF DRAIN (INSIDE):,) ' - , - SOLAR 01-00-00-8226
-. TOTAL MECHANICAL -'_'' I I -
STRONG MOTION 80-92-33-0519 . 0
TOTAL PLUMBING I FIRE SPRINKLERS 01-00-00-8227
, PUBLIC FACILITIES FEE 32-00-00-8933 p S'' . 5o
OTY. ELECTRICAL PERMIT- ISS'UE QTY. SOLAR-ISSUE
BRIDGE FEE j..
NEW CONST CA AMP/SWT'BKR '7 'COLLECTORS - SCHOOL FEE - DISTRICT
1 PH 3 PH STORAGE TANKS Carlsbad J1'•' < 80-92-21-0519
EXIST' BLDG EA AMP/SWT,iBKR ROCK STORAGE ' Encinitas 80-92-22-0519
1 PH 3 P - PUMP, San Dlegalte 80-92-23-0519
REMODEL'ALTER PER CIRCUIT PLAN CHECK FEE San_Marcos 80-92-24-0519
TEMPPOLE 200 AMPS ,
OVER200AMPS JUN _8 ____________ LICENSE -00-00-8162 _TAX _01
TEMP OCCUPANCY 130 DAYS) -
- - MFF80-92-57-0519.Q'flkJD__.
- CREDIT DEPOSIT
TOTAL
TOTALELECT R (CAL _4_-56 ILL
TOT
"M t* TOTAL FEES PAYABLE —7
-
/HAVE /HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION AND PERMtT" AND DO HEREBY Expiration. Every permit issued by the Building Official under the provisions of this I * AN OSHA PERMIT IS REQUIRED R EXCAVATIONS OVER
UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE Code shall expire by limitation and become null and void. If the building or work s 0" DEEP AMDEMOUTION OR CONSTRUCTION OF I authorized by such permit is not commenced Within 180 days from the date of such DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS permit,or ifthebuildingorworkauthorizedby suck\irssuspendedor STRI1CB,"OVER 3 STORIES IN HEIGHT
, ISSUED TO COMPLY WITH ALL CITY. COUNTY AND STATE LAWS GOVERNING BUILDING CON abandoned at any time after the work is commenced for _p_nodof180days. 4.1'_,/
STRUCTION, WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND APPLICANT'S SIQNATLLRE OWNER CONTRACTOR j APROVo BY DATE' KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND
EXPENSE WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE BY PHONE _ GRANTING OF THIS PERMIT.3AZ
TYPE I DATE INSPECTOR
BUILDING
FOUNDATION f'3"
REINFORCED STEEL
MASONRY
GUNITE OR GROUT
FLOOR & CEILING SUB FRAME
SHEATHING El ROOF El SHEAR
FRAME
EXTERIOR LATH LATH
INSULATION
INTERIOR LATH & DRYWALL g4 -C
PLUMBING
SEWER AND BL/CO EJPLICO I
UNDERGROUND ,WASTE WATER
TOP OUT El WASTE= WATER
TUB AND SHOWER PAN
GAS TEST
El WATER HEATER El SOLAR WATER
ELECTRICAL
El ELECTRIC UNDERGROUND El JFFER
ROUGH ELECTRIC I
El ELECTRIC SERVICE El TEMPOFARY
0 BONDING El POOL
MECHANICAL
0 DUCT & PLEM., El REF. PIPING
HEAT - AIR COND. SYSTEMS
VENTILATING SYSTEMS
CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATI IA
ITEMS ABOVE HAVE' BEEN APAROVED.,--
FINAL
PLUMBING
ELECTRICAL
MECHANICAL
GAS
BUILDING I
SPECIAL CONDITIONS
.;
FIELD INSPECTION RECORD
REQUIRED SPECIAL INSPECTIONS INSPECTORS NOTES
INSPECTION REQ IF
CHECKED
INSPE
APP
SOILS COMPLIANCE
PRIOR TO
FOUNDATION INSP
- •. :-
. ---
STRUCTURAL CONCRETE
OVER 2000 PSI /'T! '.j E
PRESTRESSED
CONCRETE
.4
POST TENSIONED
CONCRETE
FIELD WELDING
HI G T P ENG.T.
SPECIAL MASON
PILES CAISSONS
City of Carlsbad . . . . MISCELLANEOUS .. . . .
1200 ELM, CARLSBAD, CA 92008 • TEL. (619) 438-5525 RECEIPT
I( P,"a_ L _ Job
Address f
-
' 4.-S MISCELLANEOUS FEE RECEIPT
El
0
El
El
El
El
El
El
El
El
El
El
Address ___________________________________________
* PLAN CHECK FEE 01-00.00.8806 7
VALUATION //Pçp1,Lt.----
_- 313•
HOUSE MOVING
PARKS AND RECREATIONFEE
PUBLIC FACILITIES FEE
SCHOOL FEE - DISTRICT____________________
. Carlsbad
EnCinitas_____________________
San Diego
San Marcos
/7
_- CERTIFICATE OF OC __________
Owner _(94 -
Mailing
5 .
City . lziy I Tel. .
Contractor
Address
City
--
Zip
_-
Tel.
State Lic.
S. Classif.
City
LiC. No.
COMPLETE FOR PLAN CHECK ONLY
LEGAL DESCRIPTION i'JC, _1..o _
__ I2TI.t'£f.Z,_/tOF_'PIAJB_)W2-P2.EL,_
ASSESSORSPARCEL NO.219'OG'2 1
El
DESCRIPTIONOFWORK FAMtL_y [1
QI
PLAN ID NO. ?o 9 El
DESIGNER ADDRESS El
PHONE 72g410 El
.. fr
41
TOTAL4
CONTACT PERSON AZ (/4 *WARNING: PLAN CHECK FEES. WHERE NO ACTION IS TAKEN BY THE
APPLICANT IN 180 DAYS AND NO BUILDING PERMIT IS ISSUED. ARE
FORFEITED TO THE CITY.
COMMENTS:_______________________________________________
Lgoature of Appl can /414")_ -
S
Whit ' — Applicant.- . Yellow — File Pink (1) Finance (2) Data Process - Gold — Assesso( -.
/ —
APPLICATION FOR PERMIT TO CONNECT TO CITY SEWER SYSTEM.
CITY OF CARLSBAD 5E 23 ENGINEERING DEPARTMENT
FOR APPLICANT TO FILL IN
438.5541
ISSUED BY
DATE ISSUED —'
BUILDING
ADDRESS / -/"— , /,'%.J , VALIDATION
OWNER f , -...--.--
.. . -. MAILING
ADDRESS .4 j , / / r
7-
LATERAL CHARGE COMPUTATION -
STANDARD 4" (Max. H. 30', V. 10')
OVER 30' H.-@L—FT.
OVER 10'V. _____ ______ F,T.
STANDARD 6" (Max. H. 30', V. 10')
OVER 30' H. ______ ________ FT.
OVER 10'V. -@- FT.
TOTAL CONSTRUCTION COST
SERVICECHARGE (REPAVING ETC.)
TOTAL LATERAL CHARGE____________________
LINE COST DATA —
ASSESSMENT DIST. NO.
FRONTAGE - PER FT.—TOTAL—
OTHER
CONNECTION FEE----
—
__ NO. UNITS COST PER UNIT _______TOTAL__
CONTRACTOR
CONTRACTOR'S
ADDRESS
NEW BUILDING I I EXISTING BUILDING I X
LEGAL DESCRIPTION
1 - /• A/i" —
REMAR KS:
/ A-
LATERAL LOCATION
(I,
PUMP STATION FEES
NO. UNITS ______-COST PER UNIT—TOTAL—
i LATERAL NO.
ST.
INSTALLATION DATE_
TOTAL CHARGES (LATERAL ETC.) . - ",/-
t', p•
WHITE: Engineering GREEN: Finance YELLOW: Sanitation PINK: Building GOLDENROD: Permitter
•• . - - .
FINAL BUILDING INSPECTION
PLAN CHECK NUMBER: ( 01641 DATE: 4-23-80
PROJECT NAME:
ADDRESS: 1345 Pir
PROJECT NO.: UNIT NUMBER: PHASE NO.:
TYPE OF UNIT: NUMBER OF UNITS: 1
CONTACT PERSON: ntir
CONTACT TELEPHONE: C111 1-S7R
I rinnt
BY:
JSPED
INSPECTED:
,)7
APPROVED L4ç' DISAPPROVED
INSPECTED DATE n7/
INSPECTED: /7 /7f APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPEcTFD PPP(Wr
Rev. 1/86 WHITE: Suspense BLUE: Water District GREEN: Engineering CANARY: Utilities PINK: Planning GOLD: Fire
FINAL BUILDING INSPECTION
, .. PLAN CHECK NUMBER: $( 84-641 DATE: 14-29-88
' PROJECT NAME:
ADDRESS: 1345 Pine
PROJECTNO.: _________________ UNIT NUMBER: ________________ PHASE NO.:
TYPE OF UNIT: sfd NUMBER OF UNITS: 1
CONTACT PERSON: Gissainger
CONTACT TELEPHONE:_____________________________________________________________
all dept
BY:
JSPEE
/'J4fe
DATE
INSPECTED 7f APPROVED .3 ______ DISAPPROVED
INSPECTED DATE
BY:-_______________________ INSPECTED APPROVED ______ DISAPPROVED
INSPECTED DATE
BY ______________________ INSPECTED ___________ APPROVED ______ DISAPPROVED
' COMMENTS: -
Rev. 1186 WHITE: Suspense BLUE: Water District GREEN: Engineering CANARY: Utilities PINK: Planning GOLD: Fire
- -
FINAL BUILDING INSPECTION
PLAN CHECK NUMBER: 8L!641 DATE:
PROJECT NAME:
ADDRESS: 1L 7jr
PROJECT NO.: UNIT NUMBER: PHASE NO.:
TYPE OF UNIT: NUMBER OF UNITS:
CONTACT PERSON:
CONTACT TELEPHONE:__________________________
INSPECTED DATE MAY 02 1988 BY: &)"..— INSPECTED: APPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED
DISAPPROVED
DISAPPROVED
DISAPPROVED
Costa Real Municipa'I Water District
COMMENTS: Engineering Department
(619) 438-3367
Rev. 1/86 WHITE: Suspense BLUE: Water District GREEN: Engineering CANARY: Utilities PINK: Planning GOLD: Fire
r, FINAL BUILDING INSPECTION
PLAN CHECK NUMBER: 84641 DATE: 4-29-88
PROJECT NAME:
ADDRESS: 1345 Plre
PROJECT NO.: UNIT NUMBER: PHASE NO.:
TYPE OF UNIT: NUMBER OF UNITS: 1
CONTACT PERSON: r1incvr
Lit
t
CONTACT TELEPHONE:SIC
EVA
Q1-47R '
)
1I drrtt DEPPAW
INSPECTED
BY:
INSPECTED
BY: ______
INSPECTED
BY: ______
DATE
INSPECTED: APPROVED i.7 DISAPPROVED
DATE
INSPECTED: APPROVED DISAPPROVED
DATE
INSPECTED: APPROVED DISAPPROVED
COMMENTS:
Rev. 1/86 WHITE: Suspense BLUE: Water District GREEN: Engineering CANARY: Utilities PINK: Plannirg GOLD: Fire
FINAL BUILDING INSPECTION
1-731-11, PLAN CHECK NUMBER: 1641 DATE:
PROJECT NAME:
ADDRESS: 1343 Pt, C
PROJECT NO.: UNIT NUMBER: PHASE NO.:
TYPE OF UNIT: nhl NUMBER OF UNITS:
C
CONTACT PERSON: r
CONTACT TELEPHONE: 31337r
INSPECTED DATE VZ4 lzf BY: INSPECTED: APPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED
1
DISAPPROVED
DISAPPROVED
DISAPPROVED
COMMENTS:
Rev. 1186 WHITE: Suspense BLUE: Water District GREEN: Engineering CANARY: Utilities PINK: Planning GOLD: Fire
ESGIL CORPORATION
9320 CHESAPEAKE DR.. SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
D ATE:P/. 3/i /a 0 JURISDICTION
JURISDICTION:C7YZt$L3'L7 0 PLAN CHECKER
O FILE COPY
PLAN CHECK 0 UPS o DESIGNER
PROJECT ADDRESS: /4
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
U The plans transmitted herewith will substantially comply
with the jurisdiction's building codes, when minor deficien-
cies identified on the enclosed check list are resolved and
checked by building department staff.
U The plans transmitted herewith have major deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is the jurisdiction's
copy for your information. The plans are being held at
Esgil Corp.'until corrected plans are submitted for recheck.
0 The applicants copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
Esgil staff did not advise the applicant contact person that
plan check has been completed.
U Esgil staff did advise applicant that the plan check has
been completed. Person contacted:_________________________
Date contacted: Telephone #_____________
REMARKS:
BY: ENCL:
IL CORPORATION
Form 31584
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: - 'Ar/S .s Ci u_ LI CANT
RICT
JURISDICTION: 0 FLAt'I GHEUKE R
C] FILE COPY
PLAN CHECK NO: 9_;,4L,'-2::- o UPS
o DESIGNER
PROJECT ADDRESS: /1V 9t'c
0 The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
0 The plans transmitted herewith will substantially comply
with the jurisdiction's building codes, when minor deficien-
cies identified on the enclosed check list arp resolved and
checked by building department staff.
The plans transmitted herewith have major deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
0 The check list-transmitted herewith is the jurisdiction's
copy for your information. The plans are being held at
Esgil Corp. until corrected plans are submitted for recheck.
The applicants copy of the check list is enclosed for the
jurisdiction to return to the applicant contact- person.
0 The applicant's copy of the check list has been sent to:
Esgil staff didnot advise the applicant contact person that
plan check has been completed.
0 Esgil ataff did advise applicant that the plan check has
been completed. Person contacted:
Date contacted: Telephone
REMARKS: ___ /5AJC.Z'27 17
K" L) —i
BY _-•--. EN CL:
ESG I. CORPORATION
Form 31584
(itp of Carl.5bab
PROJECT ADDRESS,/3415 ,3.,v
TOi #/6J9iI7
LiEiiU
APPLICANT COPY
CITY COPY
PLAN CHECKER COPY
Submit fully dimensioned clot plan drawn
to scate showing location size, and use
of all existing and proposed structures
on the lot. Identify property lines and
show tot dimensions and alt eesmeents.
Show location of all cut or fill, slopes
and approximate tLniih floor elevations
for all structures and show elevations at
all corners. Sec. 302(b)?.
Indicate distance from center-tin, of street
or alley to property line and distance from
curh to property tin.. Sec. 302(b)7
Plans. specifications and calculations shall
/ be signed by a California State licensed
engineer or architect. (California
3uaifleaa and Professions Code)
3. FIR! pRO'rtCTtOl
Pt.i CDpprtON sntrr
511ctz FAMILY AND DUPLEX DtITtLI7S
Plan Check No. 494e_6 4XI-27- _______________________________
ato plans received by jurisdiction __''
Bate plans received by plan
Bete initial plan check cosplet
?RWPRO PLEASt READ
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National
Electrical Cod, and state laws regulating energy
conservation, noise attenuation and access for
the handicapped. The plan chock is based on
regulations enforced by the Building Inspection Department. You may have other corrections
based on laws and ordinances enforced by the
Planning Department, Engineering Department
or other departments.
The Items circled below need clarification*
modification or change. All circled items have
to be satisfied before the plans will, be in
conformance with the cited codes and regulations.
Per Sec. 303 (c). 1979 Uniform Building Cods. the approval of the plans dose not permit the
violation of any state, county or city Law.
,. window area must be at least 1/10 of the
floor area and a minimum o! 10 square feet
per Sec. 1207(a). Appears to be deficient
in XTA7,51. 64-
Walls closer than 3 feet to property lines
shall be one-hour fire-rated construction.
have no openings, and shall have 30 inch
parapets when the building floor area exceed.
1.000 square fast on any floor. (table S-A
Sec. 1709(a)
iL Projections. including eaves, may not extend
f more than 12 inches into the 3 foot setback
from the property line. Sec. lflG and
S.C. 504(b)
Projections. including eaves, shall be on.-
/ hour fire-resistive construction, heavy
timber or of non-combustible material if
they project into the 3' setback area from
the property line. Sec. 1710
l' Show location of Dorwanently wired saolc.
detector. Sec. 1210 4tni ).3{f' .x_-rz 5'iiiZS
C. Room SIZES. tIORT, VENTILATIONS AND ct.AZINC
One room must contain a minimum of 150 square
feet of superficial floor area. Sec. 1207(b)
Habitable rooms, other th&3 kitchens, shall
contain at least 70 square feet of floor
area. Sec. 1207(b)
28. Openable window area muse be 1/20 of the
floor area and a minimun 0,1 5 square feet.
In bathrooms, laundry rooms and similar
rooms. Minimum is 1.3 sqft. (Sec.12031a)
' One-half of all required window area east
be openable in 'T"). ow
O€TJS. r "',
Provide mechanical ventilation capable of
providing five air changes per hour in
bathrooms, water closet compartments, laundry
rooms and similar rooms it required windows
are not provided. Sec. 1205)6)
No habitable roes, other than a kitchen.
shall be less than 70 in any dimension. sec. 1207(c) -
Show that ceiling height for h.ebitablp
rooms is a minimum of 7$'. Sec. 177(4)
A. PLANS
I Please make all corrections on the original
tracings and submit two new sets of prints.
and any original plan lets that may have
Won returned to you by the jurisdiction.
tc.I
2. To facititate rechecking, plea.. Identify.
next to each circl.d item. the sheet Of
the plane upon which each correction on
this sheet has been wade and return this
Check sheet with the revised plans.
Indicate on plan, the ia.e of the legal
owner and na.e of person responsible for
the preparation jf the plane. Sec. 302(b)
NOö.4) aj Ctj
Sab o'3) -ro Fi I L51;
rt- P 7LaTh.z. L.L'. '?t', AmJ
)Y"3how ceiling neight for laundry rooms,
hallways, c0rrdors, and batnrooms is
minimum of 7'0". Sic. 1207(a)
Y Provide 30 clear width for water closet
compartments and 24" clearance in front
of water closet. Sec. 1711(b)
No cooking room shalt be used for sleeping
purposes, unless complying as an efficiency
living unit. Sec. 1208
Specify safety glazing for glazing in hazardous
locations such as glass doors, glazing
adjacent to such doors and glazing adjacent
to walking surfaces. Sec. 5406
Glazing in shower and tub enclosures
(including windows) shall be tempered,
laminated or approved plastic.
Sec. 1711 (fog)
8 Sleeping rooms shall have a window
exterior door for emergenc exit Sill
eig t ~not ccc 4 above the floor.
The window ve an 0 enabLe area of
t least 5.e feet wit he minimum
opena e an e minimum openable
height 24". Sec. 1204
Eaves and cornices may not project into
a required yard more than 2 inches for each
foot of yard width if required windows
open into the yard. Sec. 1206(d)
7 A mezzanine is an intermediate floor and
f may not have a floor area exceeding 33 1/3
percent of the total floor area in the room
below, and the mezzanine floor must have
a clear height of 7 feet. above and below,artd
must have 651 of the long side open to the
room below.
The loft you show does not comply as a
' mezzanine floor and is. by Building Code
definition, a story____________________________
0. EXITS, STAIRWAYS, AND RAILINGS
Floor above the second story shall have
/ not less than 2 exits. Sec. 3302(a)
Required exit doorways shall be not lees
/ than 36" in width and not less than 6-6"
in height, and shall be capable of opening
at least 90 degrees. Sec. 3303(e)
Provide 36" high protective railing for
I porches, balconies, and open sides of landings.
Maximum opening between railings shall be
less than 9. Sec. 1716
Show how guardrail connection ietajls are
I adequate to support 20 pounds per Lina1
foot at a right angle to the top rail.
Table 23-9
Provide stairway and landing details.
' Sec. 3305(b) & (c)
Maximum rise 8" and minimum run is 9".
Minimum head room is 6-6".
C. Minimum width is 30".
SHandrails shall satisfy the following:
Provide handrail for stairways over 30"
high when serving a single dwelling.
Title 24, Sec. T25-22(b)
Handrail shall be 30" to 34" above the
nosing of treads. Sec. 3305(j)
c Handrail projerting from a wall
have a space nt less than 1 1/2" between 1P'
the wall and tne handrail.
The hand grip portion of handrail shall
be not less than I 1/4 nor more than (
2 in cross-sectional dizsens ion.
Sec. 3305(j) (se, attached)
Every stairway landing shall have a dimension.
/ measured in the di:ection of travel, at
least equal to the stairway width.
Sec. 3305(g)
A door may open over a stairway landing
provided the door, in any position, does
not reduce the clear area of the landing,
in the direction of stairway travel, to
less than one-half the required width of
the stairway. Sec 3305(g)
A door may open inward at the top step of
a stairway provided the top step is not
more than 7 1/2" lower than the floor level.
,Sec. 3303(1)2
Provide details of winding stairway.
Minimum tread is 6 inches at any point
and minimum 9 inches at a point 12 inches
from the side of the stairway.
Maximum rise is 9 inches.
Minimum width it 30 inches. Sec. 3305(d)
(see attached)
/5 Provide spiral stairway details:
Minimum run is 1/2 inches at a point
from where the tread is the narrowest.
Maximum rise is 9 1/2 inches.
C. Minimum headroor. is 6 feet 6 inches.
Sec. 3305(f)
(see attached)
5/. Sprial stairways may not be used for required
exits when th
e area served is greater than
400 sq. ft. Sec. 3305(f)
5/ Spiral stairways must have a clear walking
space of 26 inches between the column and
handrail. Sec. 3305(f)
5/. Provide Z.C.B.O. R,asearch Report and Number
for metal stairway, or submit plans and
calculations and approved fabricator
registered with the Building Department
or note that the stairway fabrication shall
be done under special inspection per the
approved fabricaticn plans. Sec. 306(a)43
and Sec. 306(f)
in buildings over 2 stories in height, provide
' 3/4 hour fire-rated assemblies for all
openings in the exterior wall below or within
10 feet horizontally of an exterior stair-
y. An exit balcony with 2 separated
14'tairways is exempt. Sec. 3305
6 ' Exterior stairways shall not project into
the 3 foot setback from tne property lines.
Sec. 3305(n)
The walls and sof!its of %he enclosed -aseable
space under interior St shall be protected]
on .he enclosed side as required for one hour
fire-resistive construction. Sec. 3303(m)
Minimum construction specifications shalt
be made S part of the approved plans.
(See attached)
Show I 3/8" solid core self-closing door
e' for openings between garage and dwelling.
,Sec. 503(d)
t..( Garages are not permitted to open into
a room used for sleeping purposes. Sec. 1104
ijf. Openings between carport and residence
-" require self-closing doors and stationary
window.. Sec. 1214
X. ROOFING Show garage framing section, size of header
te over garage opening, lateral cross bracing
7J Specify roof pitch. - at plate Line and method of bracing garage
Roof pitch is not adequate for roof type front. Chapter 23
specified. Specify minimum pitch of NOT!: Minimum plywood diaphragm ratio is
1/2 to I or 2'B. Table 24-I
72 Specify roof material and appLicatio)'L)' et Doors between dwellings and attached garages
may swing in either direction provided
Specify t.C.3.O. approval number for roof the difference in floor elevation between
materials not covered in UBC. / the dwelling and garage does not exceed
7 1/2 inches and provided the door is not
)4'(Specify roof slope for drainage or design used as the primary means of egress from 7 to support accumulated water. Sec. 3207(a) the building.
Show roof drains and overflows. Sec. 3207(a) If the difference in floor elevation exceeds
"73<' Provide skylight details to show compliance 7 1/2 inches, or if the door is used as
with Sections 3401 and 5207 or provide ICBO the primary means of egress-from the building,
approval number, additional steps or landing must be provided
in accordance with stairway requirements.
7/ Provide plastic roof panel details to show and the door must not swing over the depressed
Compliance with Section 5206 or provide level. (see 3303(i)2 and 3305 (q).
ICaO number. Y Provide IS" raised platforms for any FAU.
)i. Show attic ventilation. Minimum vent area water heater, or any other device which
" is 1/150 of attic area or 1/300 of attice ,may generate a flame or spark.
area if at least 501 of the required vent
is at least 3 feet above ceiling joists.
Sec. 3205(c)
H. MASONRY
ai. Provide' fireplace construction details or
/ note construction to be per attached fireplace
standard drawing. Sec. 3707
31. Show veneer support and connections comply
with Sec. 3002. 4,5.6, and Sec. 2516(a)
regarding ties and *9 wire in horizontal
joints or note construction to be per attached
sheets 30-1 or 30-2.
pl. Show height and construction details of
all masonry wails. Chapter 24
Note that cleanout openings shall be' provided
/ at the bottom of all cells to be grout filled
over 4' in a single pour. Cleanout shall
be sealed before grouting, after inspection.
Sec. 2415
9/. Show floor and roof connections to masonry
per lineal foot or the actual design load,
whichever is greater. Sec. 2310
91 Provide material specifications for mortar. / grout, masonry and reinforcing steel.
Sec. 2403
9/. Show how masonry house walls retaining earth
are to be waterproofed. Provide detail.
9/. Note that special inspection of the masonry
/ will be required for___________________________
C. JGARAGE AND CARPORTS
1)d'Carage requires one-hour fire protection
7 on the garage side of walls and ceilings
/omtnon to the dwelling. Table 5-9 Sec.503(b)
191'.All elements supporting floor above garage / to have one-hour fire-resistive protection
/ on the garage side. Sec. 303. Beams and
posts, not within the wall or ceiling con-
struction, must comply with USC. Table 43-A,
or be minimum 6" dimension beam and minimum
5" by V post.
1 . Note that continuous fire wall protection
shall be ins in-stalled behind raised platform(s)
prior to framing platform.
FOUNDATION REQUIREMENTS
19. Note on plans that"A soils engineer shall
evaluate any unanticipated uncompacted fill
or expansive soil or other soil problems
J
20
disclosed during construction". Sec.306(a)12.
Submit soils classification determination
.t by a licensed engineer or architect -based
on observatior, tests, borings, or excavations,
and containing comments on the degree of
'4 expansiveness, compressibility and bearing
value. Sec. 2905
21. Note on the plan the soils classification,
'I whether or not the soil is expansive, and
note the allowable bearing value. Sec. 2905
22. The foundation plan does not comply with
the soil report recommendation for this
I walls. Connection shalt resist 200 pounds
project_____________________________________
23. Provide notes on the foundation plan listing
the soils report recommendations for foundations.
V) slab and building pad preparation.
') 24. Note on the foundation plan that "Prior
to the Contractor requesting a Building
Department foundation inspection, the
- soils engineer shall advise the Building
At Official in writing that:
I. the building pad was prepared in accor-
dance with the soils report:
, the utility trenches have been properly
backfilled and compacted, and:
. the foundation excavations, forming
and reinforcement comply with the soils
report and approved plan."
25. Provide spread footings for concentrated
loads designed for 1.000 ?SF soil bearing
or per bearing value as determined by
an engineer or architect. Chapter 29
/MOt3 Ut..tTtCM (0U!'tEtSP
ihow iSC5I.5 ,f duplex 01es01% •p.ICt'f' .4115
and oar. :.ilina issumoties CO acU.v.
I Sound 7r3n32LSS&0A 315 tST) racing
in .all' ot So l.cibl.i md 4n maccc
Insulation .155 1(1i) racing on hour.
/ ceiling of 30 4ecioi46. '?itt.. 23
Show now penetration of asiesollea for
piping. electrical devices. recessed caOiliecs.
b.4CJ1tUO5. moffita. or heating ventilating.
Or exasuat ducts ittall be sealed. lined-
at insulated to maintain required sound
/ transmission rating. Title 23
Provide insulation in watts and ceiling
to ace,. S?C of 30 between garage and
Living-area ,.f garage use is not controlled
by resident TitLe 23.
LPFERGY CONSERVATION, Pt.... Seed
New State Mandated Regulations (Calif. Admin. Code) became effective
Jun. 16, 1983 and require that the design satisfy one of the alternative
energy packages (see attached packages A. B. C. 1, 2, 3, 4 and AS 1631. The
law also requires that many mandatory
cans.,rvation items be satisfied.
in Zone 7
Copies of the Residential Energy
Conservation Manual may be obtained
from: Publications Unit, California
Energy Coaission, 1111 Howe Ave. NS-50, Sacramento, California 95825, (?.l. (916) 920-6216)). California Building Officials also maintain a telephone 'hotline between 10:00 A.A. and Noon and 1:00 P.R. to 4100 P.11. at (916)
27 •
456-3823.
Show on the title sheet of the plans,
the alternative energy package that was selected i.e. A. B. C. 1. 2, 3, 4, or AS 163 to show complianc., and provide calculations and other data,
27 •
appropriate to that selected package.
The responsible designer should !Ifl a statement, on the clan title sheet. The design submitted substantially conforms to the Energy Regulation.
.,4.
for Residential Buildings'.
Show the 1' value for the walls and / Coiling and related areas.
275. Not, that the insulation used shell
, comply with California Quality Standards.
Note the insulation installer shall 6 post a signed certificate, in a conspicioas
place in the building, stating the
insulation complies with Title 24, Chapter
2-53 and Title 20, Chapter 2, Subchapter
4, Article 3.
Note doors and windows, including skylights, / between conditioned and non-conditioned
Space shall be fully weatherstripped.
278 Note on the framing plan that weather-
stripping, caulking or sealants must be used to limit filtration in the building envelop, at the following locatioeas
Exterior joints around windows and door
frames; between wall sole plates and floors,
and ,otw..n extdrior wait panets;
penetrations in walls, ceilings, and
floors for plumbing, electricity, and
gas Imnus; openings in attic floor.:
and mit other openings in the building
J envalopu.
Note that doors and window, to be certified
and laceled as complying with the Energy
Regulations.
.50. Note fans exhausting air to have back
draft dampers.
8I. Note at the e.t.rtor alt fireplace Tmr-olacs to esiriaua six squate
inches of Outside air; to have glass
or metal door cov.rinq the entire opening of the f irebox: to have tight-fitting
damper with readily accessible control
and should not have a continuous burning
pilot 1iqrmt.
28 . Note ducts shall comply with Chapter 10,
1976 UNC and shall be tightly sealed with mastic or tape.
28 . Note at the water heater location water
heater to have wrap of 5-12 external
insulation'.
28 . Note, where water heater is in unconditioned
space, the first live feet of outlet pipe to have 5-3. wrap.
2$'. Note all circulating hot water pipes
,.' in unconditioned spaces shall be insulated.
28 • Note that all gas fired heating and
cooling appliances, showers and faucets
Shall comply with the Energy Efficiency
Standards.
Show, at bath and kitchen, that the
' general lighting shall have an efficiency
of not less than 23 lumene per watt
i.e. florescent.
28 . Note that heating or cooling systema (excopt heat pumps) shall have ui automatic
thermostat with mechanism which can be
manually programmed to automatically
MARC beck the thermostat set points for at least two periods within 24 hours.
28 . Show the size, type and location of
P
the space heating (or cooling) system
and provide energy calculations if the
output BTU/Mr. exceeds 43,000 BTU/)Lr. output,
29 Nefl mak, and model for PRO and wec heater
.rc M State approved lIst.
3$' Outdoor pools witn fossil fuel heaterS
require pact covers as well as ocner energy saving devices sucn an Cia. ciocz.s. etc. .24-L406
9:. MISCLLAN'!OtIS
Show a minimum 2' air !pace and flashing
between planter and building walls. XSec. 25171.)
X2 Specify material to be used under the 7 , shower tile. Sec. 170(a)
30. Specify Lath and plaster to comply with
Chapter 47, DOC.
6). Two 3/4' copper pipes rust be installed
from water heater Location to convenient location of future solar panels (City Ord.)
Provide sleeves (roof jacks) in roof for
two future 3/6' copper pipes to ci.,nvenjent
Location of futur, solar panels (City Ord.)
o Not. :nat solar water piping is to be insulated in areas that are ot heated or tooled, (City Ord,l
0 Building plans are substantially correct and complete.
By,
Dotal
Building plans would be substantially correct
and complete is minor corrections are made at counter.
By,
Date:
0 8 ilding plans require major corrections and
oniplete plan recheck, by plan Check
engineer, is required. By
DateI-
1! you have any question, regarding
this p1 check, please call ZIrI'_1
t 6177
we would also be pleased to meet with you, at no charge, if addtional aeeistance is needed.
i.
Show height of all foundation walls. Chapter 23 ,' Note cross bridging or blocking. Floor
joists and rafters more than 12' in depth
Show height of retained earth on all foundation and spanning more than 8 feet shall be
walls. Chapter Z3 supported laterally by bridging at intervals
1)4. Show distance of foundation to edge c not exceeding 8 feet. Sec. 2506(q)
I' cut or fill Slopes and show steepness and Show blocking at ends and at supports
he&ghcs of cuts and fills. Chapter 29 of floor joists, and for rafters at exterior
/19-
Note on plans that wood shalt S. 6' above walls. S.C. 2506(g)
finish grad.. Sec. 2417(c) 7. Y. Show solid blocking at ridge tine and
yi(. Note on plans that surface water will drain at exterior walls on trussed roofs.
away from building and Show drainage pattern Sec. 2506(g)
and key elevations. Sec. 2905(f) ,frS' Show double joists. Floor joists shall
Dimension foundation per Table 29A. be doubled under bearing partitions running
parallel with the joists. Sec. 2518(d) S
y1' Show rafter ties. Rafter ties shalt be
TABLE NO. 29.A—FOUNDAT1ONS FOR STUD BEARING spaced not more than 4 feet on center
WALLS—MINIMUM REQUIREMENTS where rafters and ceiling joists are not
-
narallel Sec 2518(h)
D(P1,W OF
FOUNDATION
WIDTH THICKNESS ICLOW
SUMS(R THICKNESS OF OF OF NATURAL
OF FOUNDATION WALl. FOOTING FOOTING SURFACE
STORIES (l.cftss) leaflet) (lncAs OF GROUND
AND FINISH
CONCRETE UNIT
I
MASONRY
GAAOE
(teasel)
1 6 8 116 12
2 8 ,8 IS 7 18
3 10 10 18 8 24
lfr'f( Show rafter purlin braces to be not less
than 45 degrees to the horizontal.
/Sec. 2518(h)
I.
Show 1/2' minimum clearance between top
plate of interior partitions and bottom
chord of trusses. (To ensure loading
will be as designed.)
Show double top plate with minimum 48'
/ tap splice. Sec. 2518(g)4
17 Show nailing will be in compliance with
.,.f" Table 25-P.
.511 fl *...A 04-------5.-------------
-- - - -------
NOTES:
Jc c,.aflca
top story and roof space, at ceilings
Wbese unusual coitditiOft, or frost conditions are found. footings and and floor levels in interior and exterior
foundations shall be as required in Section '907 1a). walls, in mansard roof or eyebrow so no
The around under the floor may be excavated to the elevation of the concealed or furred space is greater than
top of the tontine. - I
10' horizontally or vertically, between
stair Stringers at top and bottom and
Show foundation sills to be pressure treated,
between studs along and in line with
or equal. Sec. 2517(-c) 3.
s€air run adjoining stud walls and partitions
at perimeter of sliding door pockets.
Show foundation bolt size and spacing.
:~
between chimney and wood frame using meta
Sec. 2907(e) or incombustibles for the fire stop and
Specify size. XCSO number and manufacture
at other places that could afford passage
of power driven pins. Show edge and end
distance and spacing. Sac. 306(f)
of flame. Sec. 2517(f)
Show stud size and spacing. Maximum allow-
13 . Show size, imbedmettt and location of hold able stud heights: 2x4"9 16' is 14
down anchors on foundation plan. Sec. 23 3'x4"&2'x6'9 16"o.c. is 20'. Sec. 2518(g)2
Note on plan that hold down anchors must 9'
be
Note an A.I.T.C. Certificate of Compliance
tied in place prior to foundation insp
for glued laminated wood members shall
Sec. 2312(f)
be given to the Building Inspector prier
Show adequate footings under all shear
Yc.
to erection. Sec. 306(f)
walls. Sec. 2311(e)
Detail all post to beam and post to footing
connections. Sec. 2517(c) 4
Show Stepped footings for slopes steeper
, than 1:10. Sec. 2907(c)
Specify nail size and spacing for all
shear walls, floor and roof diaphragms.
Show minimum 18' clearance from grade to Indicate required blocking. Maintain
bottom of floor joists and minimum 12' maximum diaphragm dimension ratios.
clearance to bottom of girders. Sec. 2517 (Tables I.J.X). -
I/.
Show pier size, spacing and depth into JW Show 3'x4' or 2x6' studs in first story
undisturbed soil. Table 29-A of three story building. Sec. 2518(f)
y. Show minimum under floor access of 18x 24'. . Provide truss details and truss calculations.
Sec, 2517
l4'. Show minimum under floor ventilation equal iJ(. Provide roof framing plan. Sec. 302(a)7
to 1 1/2 sq. ft. for each 25 lineal feet ,y4. Provide framing sections through_____________
of exterior foundation with openings as
close to corners as practicable to provide
cross ventilation on at least two approximate. Section 302(a) 7
ty opposite sides. Sec. 2517 ,,( Specify all header sizes for opening over
2. FRAMING
160 Show all joists, rafters, beams, and posts
2 to 4' thick to be No. 2 Grade Douglas
Fir-Larch or better. All posts and beams
5' and thicker shalt be No. 1 Grade Douglas
Fir-(.arch or better. (Table 25-A-1)
Show well bracing. Every exterior wood
stud wall and main cross partition shall
be braced at each end and at least every
25 feet of length with 1x4 diagonal
let-in brace or equivalent. Sec. 2518(9)5
l9) Provide calculations for____________________
Section 302(a) 7
In areas subject to water splash and in
exterior locations, wood columns and posts
shall be supported by piers pro)ecting
at least 2' above the finished grade and
shall bear on a metal base plate or treated
wood unless the columns or posts or* foun-
dation grade redwood or cedar. Sec. 2517(04
frtShow location of attir access with minimun
size 22 x 30. Sec. 3205
4. Show draft separation for attic areas
' in excess of 3.000 sq.ft. Sec. 3205
Show draft seosration for space between
drooped ceilings and floor above in excess
of 1.000 sq.ft. Sec. 2517
Specify plywood grade and panel indentL-
fLcaton index. ?able 25-S
1,,1'. When roof pitch is less than 3:12, desLqn
# ridge as a seam. Sec. 2518 (t)
Wood shear walls shall not be used to
resist horizontal forces contributed by
masonry in buildings over on* story in
, height. Sec. 2516(b)
ItS. Gypsum lath and plaster, gypsum sheathing
board and gypsum wallboard shall not be
used in vertical diaphragms to resist
forces imposed by masonry or concrete
construction. Table 47-1
If cripple wall studs are less than 14,
F , framing shall be solid blocking. Sec.2518(g)
)4'l. Cripple wall studs exceeding 4 feet in
height shall be 3 inch by 4 inch or 2
inches by 6 inches when supporting 2 stories.
Sec. 2518(g)6
)4. Show plywood sheathing over exposed eaves,
or other weather exposed areas, is exterior
grade. Sec. 2517(g) 3
19 . Show a weep screed at the foundation plate
line on all exterior stud walls to be
;;;:;:: :;p;o; waterproof building
paper under wood siding. Sec. 1701(a)
Specify an approved flashing for exterior
/ openings and parapet wells. Sec. 3208
Show corridor width to be minimum 36.
Sec. 3304(b)
Specify truss layout for 30 x 30 attic
/ access.
y4. Ridges, hips, and valleys shall be at
least one size larger than supported
rafters. Sec. 2518(h) 3
19 . Provide metal straps across ridge beam
and rafters.
Show access to th. attic or under floor
." furnace to be mnamum 30 inches by 30
inches. S.c. 708 709 UMC
9. Note that passageway to the attic furnace
shall be unobstructed and have continuous
solid floorinq not Less than 24 inches
/ wide. Sec 708 UMC
Show permanent electrical outlet and
lighting fL.'cture controlled by a switch
for the attic furnace. Sec. 708 UMC
2Z Show details to comply with Section '709
.f for furnace under the floor. Section 708
for attic furnace, or Section 710 for
roof or outside furnace.
21 . Note on plan, gas vents and non-combustible
piping passing through three floors or
less shall be effectively draft stopped
at each floor or ceiling. (JOC Sec. 1706(a)6
K. ELECFRICAL. (National Electrical Code)
All wiring shall comply dith the National Electrical
Code.
6 2 . Note on the plan tl'e amperage of electrical
service.
22 . If the electrical installation is more
than 200 amperes, show panel location
and provide a single line diagram and
load calculations including: , a. Wiring method employed.
b. Sizes of all conductors, switches,
circuit breake:s, fuses, and conduits.
C. Approximate length of service feeders.
d. Provide plot plan showing services,
all panel locations, circuit arrangement
and load distribution on panel busses.
- fl-,.... A .....,4 .,.,._t _.I,4.. I_I - I - •-•'---"--zw--- •
2 . Dwellings require minimum tOO amp service.
Show location of all electrical receptacles.
2 . Electrical receptacle locations end/or
spacing is not adequate in tJOF ).rr.C11Z.;
2)S' At least one receptacle shall be installed
outdoors, in basements and attached garages,
other than laundry outlets. Art. 210-25(b)
Show minimum dw1ling lighting (NEC
Art. 210-26(a) and E'I.S in garage, baths
and outdoors. NEC Art. 210-8(a).
Note ground to be provided (NEC).
S.MECHANICAL #• Art. u-e
All heating, ventilating, and cooling systems
and appliances shall comply with the Uniform
Mechanical Code. L. PLUMBING (Uniform Plumbing Code)
Show the size, location and type of all
heating and cooling appliances or systems. All plumbing shall comply with the Unifrom
Plumbing Code.
Show source of combustion air for furnace 2Jg' - Show water heater size, type and will comply with Chaper 6, U.M.C.
Every dwelling
location
unit shall be provided with
on plans.
heating facilities capable of maintain- S Show method of providing combustion air
ing a room temperature of 70 F. at 3 to fuel burning water heater. Sec. 1307
W,. feet above the floor in all habitable Fuel combustion water heater shall not be
rooms. Show basis for compliance. UBC installed in bath or bedroom or in a closet
Sec. 1211 opening into bath or bedroom. Sec. 1309
Show minimum 30 deep unobstructed working }4'. Provide adequate barrier to protect water
20
space n front of furnace,
Note on plans,clearances to be per manufac 3.1€. heater from vehicle damage. Sec. 1310
Show 'F and P valve on water heater and
turers listing. Sec. 704 UMC show route of discharge line to exterior
Furnace shall not be installed under any Sec. 1007(e)
stairway. Sec. 704 UMC Provide dryer vent to outside. UMC
Furnace shall not be installed in any Sec. 1903
bedroom, oathroom, closet, or in confined . Note on the plan that hose bibbs and lawn
space with access only through such room, sprinkler systems shall have approved
unless specified as direct vent appliance. backflow prevention devices. Sec. 1003
enclosed furnace or electric heating appliance.
Sec. 704 UMC ,)K(. Shower stall shall accoinodat. a 30circ1e
and have a minimum floor area of 900 sq.in.
Show IC3O approval for prefab fireplace UPC 909(d)
and provide approved installation instructions
at job site.
I .
* Z~/ Date
Prepared by
Jurisdiction________________
Bldg. Dept.
VALUATION AND PLAN CHECK FEE Esgil
PLAN CHECK NO.
BUILDING ADDRESS 3 4'5 '-'
APPLICANT/CONTACTO¼/3 Chlel,5 PHONE NO. -7:Z57 B3 2
BUILDING OCCUPANCY ,0-3. /1 DESIGNER PHONE_____________
TYPE OF CONSTRUCTION V-1 CONTRACTOR PHONE___________
BUILDING PORTION BUILDING AREA VALUATION
MULTIPLIER
VALUE
oa
Air ConditioninE
Commercial 2.80
Residential
-
2.40 -
Res. or Comm.-
Fire Sprinklers
1.50
Total Value /.'2'.
Fee Adjusted To Reflect 0 Energy Regulations (Fee x
0 Handicapped Regulations (FeO 1.065)
Building Permit Fee $________
Plan Check F e e &
COMMENTS:
8/4/82
I
PLAN CHECK NUMBER ADDRESS DATE/
PLANNING: PPE OF STRUCTURE ZONE:____________ -
SCHOOL FEES: SAN DIEGUITO ms
ENC[NITAS____________________
1. CARLSBAD SAN MARCOS______________________
REQUIRED SETBACKS_______________
FRONT
-
SIDE UU (2
REAR
% COVERAGE_______________________________
BUILDING HEIGHT 17
FENCES/WALLS
TWO CAR GARAGE_______________________
C0'lMENTS:________________________________
Cl REDEVELOPMENT APPROVAL REQUIRED:
Lu
LANDSCAPE PLAN COMMENTS: NJ 1
ENVIRONMENTAL REQUIRED:
ADDITIONAL COMMENTS:
OK TO ISSUE:_JZf DATE: U'jilfX'7OK TO FINAL: DATE:____________
ENGINEEflING/1-c---2_/ LEGAL DESCRIPTION VERIFIED?>E A.P.N. CHECKED
P. F. F. PARK IN LIEU
R.0.14: IMPROVEMENTS: .
tI ttLi t- fr2'v - &40fliq Ye!.
E. D . U:
77 -J;
- r' LATERAL: AJZ' ' L-__ DRIVEWAY: IJ 7;'.
GRADING PERMIT:
DRAINAGE:
EASEMENTS: ,J-4 AtJ1 ADDITIONAL COMMENTS: Ln
04 MIA10AR LAJ
uj
cr-
LJ
OKTO ISSUE: DATE:____________________________
* ENGINEERING It'1$'PECT0f4jREQUIRED:
PUBLIC WORKS fl'S2Et TOR: __________________________________________________________
FINAL OK: DATE:
* IF THIS ITEM IS NOT CHECKED, BUILDING DEPARTMENT WILL MAKE ALL INSPECTIONS
(DRIVEWAYS, CURB CUT, DRAINAGE, ETC.)
SEWER:
ATTENTION ,PROPERTY OWNER:
An downer-builder" building permit has been applied for In your name and bearing your
signature.
Please complete and return this Information in the envelope provided at your earliest
opportunity to avoid --unnecessary delay In processing and Issuing your building permit.
No building permit will be issued until this verification Is received.
I personally plan to provide the major labor and materials for construction of
the proposed property improvement (yes or no) ________
I (have/have not) -
signed the application for a building permit.
I have contracted with the following person (firm) to provide the proposed construction.
Name Phone
AddresS
_&Contractors License No.
city
I plan to provide portions of the work, but I have hired the following person to
coordinate, supervise and provide the major work.
Name f Phone
Address pJ \ f/ Contractors License No.
City V
5 I will provide some of the work bu I have contracted (hired) the following persons
to provide the work Indicated:
Name Address Phone Type of Work
Signed: Property Owner
Social Security Number b4 —19'-- ( 9a P
Date:
EACH SUBCONTRACTOR WILL BE INSTRUCTED TO OBTAIN A CITY OF CARLSBAD BUSINESS LICENSE
AND FURNISH A CERTIFICATE OF WORKMAN'S COMPENSATION TO THE CITY OF CARLSBAD.
eGeX Initials
Ir DEVELOPMENTAL
SERVICES
BUILDING DEPARTMENT
TY'
(ftitp of QtarlSbab.
1200 ELMA1ENuE
CARLSBAD, CALIFORNIA 92008-1989
(619) 438-5525
Dear Property Owner:
An application for a building permit has been submitted In your name listing yourself
as the builder of the property improvements specified. For your protection you should be
aware that as "owner-builder you are the responsible party of record on such a permit.
Building permits are not required to be signed by the property owners unless they are
personally performing their own work. If your work is being performed by someone other
than yourself, you may protect yourself from possible liability If that person applies for
the proper permit in his or her name.
Contractors are required by law to be licensed and bonded by the State of California and
to have a business license from the City of Carlsbad. They are also required by law to
put their license number on all permits for which they apply.
If you plan to do your own work, with the exception of various trades that you plan to
subcontract, you should be aware of the following information for your benefit and pro-
tection. If you employ or otherwise engage any persons other than your immediate family,
and the work (including material and other costs) is $200 or more for the entire project,
and such persons are not licensed as contractors or subcontractors, then you may be an
employer. If you are an employer, you must register with the state and federal government
as an employer and you are subject to several obligations including state and federal
income withholding, federal social security taxes, workers' compensation
disability insurance costs, and unemployment contributions. There may be ____
for you If you do not carry out these oblinations and these risks are esn
For specific information about your obligations under federal law, contact the Internal
Revenue Service (and, if you wish, the U.S. Small Business Administration). For more
specific information about your obligations under state law, contact the Department of
Benefit Payments and the Division of Industrial Accidents.
If the structure is intended for sale, property owners who are not licensed contractors
are allowed to perform their work personally or through their own employees, without
a licensed contractor or subcontractor, only under limited conditions.
A frequent practice of unlicensed persons professing to be contractors is to secure an
"owner-builder" building permit, erroneously implying that the property owner is providing
his or he! own labor and material personally. Building permits are not required to be
signed by property owners unless they are performing their own work personally. Informa-
tion about licensed contractors may be obtained by contacting the Contractors State
License Board in your community or at 1020 N Street, Sacramento, CA 95814.
PLEASE COMPLETE AND RETURN THE ENCLOSED OWNER-BUILDER VERIFICATION FORM SO THAT WE CAN
CONFIRM THAT YOU ARE AWARE OF THESE MATTERS. THE BUILDING PERMIT WILL NOT BE ISSUED
UNTIL THE VERIFICATION IS RETURNED.