HomeMy WebLinkAbout1347 CASSINS ST; ; CB970275; PermitBUILDING PERMIT
02/13/97 09: 2 9
Page 1 of 1
i Job Address: 1347 CASSINS ST Suite:
Permit Type: PATIO/DECK
Parcel No: 215-690-27-00 Lot# :
Valuation: 1,242
Occupancy Group: Reference*:
Description: COVERED PATIO 184 SF
Permit No: CB970275
Project No: A9700335
Development No:
Appl/Ownr : TAMBORELLI CONSTRUCTION
28520 HUCKLEBERRY LANE
SAN MARCOS, CA 92069
*** Fees Required *** *
2526 02/13/97 0001 01 02
C-PRHT 52.00Construction Type: NEW
Status: ISSUED
Applied: 02/13/97
Apr/Issue: 02/13/97
Entered By: JM
619 975-2043
Collected & Credits
Fees :
Adjustments:
Total Fees:
Fee description
Building Permit
Plan Check
Strong Motion Fee
* BUILDING TOTAL
52. 0!
. 0 0
. 0 0
5 2 . 0 0
Ext fee Data
31.0 0
2 0 . 0 0
1 . U 0
52 . 00
APPROVAL
INS
CLEARANCE.
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
20>5 Las Palmas Dr., Carlsbad CA 92009
(619)438-1161
"«W^
FOR OFFICE USE ONLY _
PLAN CHECK NO.?"?^'J
EST. VAL..
Plan Ck. Deposit
Validated By.
Date
Address (include Bldg/Suite *)Business Name (at this address)
Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total * of units
Assessor's Parcel t Existing Use Proposed Use
Description of Wi SO. FT.*of Stories * of Bedrooms,# of Bathrooms
Name City State/Zip Telephone * Fax *
Name State/Zip Telephone #
Name Address City State/Zip Telephone *
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemption._AnM.violatiorj of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not mormjhan five hundred dollars I» 5001)
vtr 2S>£20 HudtioLesAs LAJ
State License # *J TT^t
Designer Name
State License # <^--*"
~-Jt?7l Addra8S & //fO License Class ^> /
^s
^.^^ Address
^\
CHty ' State/Zip, / <J>/o'
City Business License * / / ' A-
City
tyr*
State/Zip Telephone
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
O I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for'which this permit is
issued. My worker's compensation insurance carrier and policy number are:
Insurance Company Policy No. Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS 1*100} OR LESS)
CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
subject to the Workers' Compensation Laws of California.
WARNING: Failure to saeure- workers' compensation coverage j* unlawful, and shell subject an employer to criminal penalties end dstt fines up to one hundred
thousand dollars (S10MOOO), in addition to the/cost of compe/^BUefC^eges as provided for hi Section 3706 of the LataMAd*jntefest and attorney's fees.
' /^< £ r^^TJ^. DATE
R-BUttDERDECLAR^TION *
I heretfy-effrrm that I am exempt from the Contractor's License Law for the following reason:
Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, end who does
such work himself or through his own employees, provided that such improvements ere not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
D I. as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractorlsl licensed
pursuant to the Contractor's License Lew).
[3 I em exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor end materials for construction of the proposed property improvement. Q YES QNO
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number): •
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work):
DATEPROPERTY OWNER SIGNATURE
^MPJ^THIS SECTION FOR «P^^
Is ths applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 2SS05, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES O NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O YES D N0
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? O YES D NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is e construction lending egency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
?9; APPLICANT CERTIFICATION -.'-,', •,-*?£•*
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances end Stste lews relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES.
OSHA: An OSHA permit is required for excavations over 5'0* deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shaH expire by limitation and become
work authorized by such permit is not commenced within 365 days from tbe^date of^uch permit or if the building or work »
or abandoned at any time after the wodtts commenced fore'period of laxJays ISeebdh 106.4.4 Uniform Building Code).
APPLICANT'S SIGNATURE DATE
if the building or
mrt is suspended
WHITE: File YELLOW: Applicant PINK: Finance /
CITY OF CARLSBAD
INSPECTION REQUEST
PERMIT* CB970275 FOR 08/12/97
DESCRIPTION: COVERED PATIO 184 SF
TYPE: PATIO
JOB ADDRESS: 1347 CASSINS ST
APPLICANT: TAMBORELLI CONSTRUCTION
CONTRACTOR:
OWNER:
REMARKS: C/JOE/990-2852
SPECIAL INSTRUCT:
INSPECTOR AREA PD
PLANCK# CB970275
OCC GRP
CONSTR. TYPE NEW
STE: LOT:
PHONE: 619 975-2043
PHONE:
PHONE:
INSPECTO:
TOTAL TIME:
CD LVL DESCRIPTION
19 ST Final Structural
ACT COMMENTS
***** INSPECTION HISTORY *****
DATE DESCRIPTION
021497 Ftg/Foundation/Piers
ACT INSP
AP PD
COMMENTS
07/12/97 - INSPECTION HISTORY LISTING
FOR PERMIT* CB970275
DATE INSPECTION TYPE INSP ACT COMMENTS
02/14/97 Ftg/Foundation/Piers RI RI MW/JOEY/975-2043
02/14/97 Ftg/Foundation/Piers PD AP
HIT <RETURN> TO CONTINUE...
City of Carlsbad
Building Department
RESIDENTIAL PATIO COVERS
Patio covers are one story, roofed structures not more than 12 feet above grade and
used for outdoor recreational purposes. A Building Permit is required for patio covers
attached to a residence. Residential patio covers less than 300 square feet in size and
at least ten feet from any other structure on the lot do not require a building permit from
the City. But all patio covers, permitted or not, must comply with the setback
requirements in this handout. This hand out describes what plans are necessary to
secure a patio cover permit. To assist you, there is a sample of a plot plan, span tables
for joists, and beams, and there is a footing schedule for foundation requirements.
There are also connection details to use for typical connections. You may use this
handout in lieu of a separate design. If you design the patio cover yourself, or your patio
cover is outside the span table limits in this handout, please provide a foundation plan,
framing details, and other details and elevations to show the extent of the proposed
work.
If you use the attached tables and plans please submit:
1. Two Identical Site Plans showing:
a) Property lines with dimensions.
b) Proposed roof area of the patio cover.
c) Distances from posts to property lines.
d) All existing structures on the property.
e) Indicate the dimensions of the patio cover and the total roofed area.
f) Any easements on the property.
g) Show slopes or topography of the lot
2. A Building Permit Application with the following:
a. Name of the property owner.
b. Home Phone Number
c. Site address, assessor's parcel number, lot number, subdivision name or
number.
d. Contractor's name, State License Number and City Business License
Number; or an Owner-Builder Declaration Form (Available at the Building
Department Counter).
e. Signature of Applicant
If you are applying for a building permit in the Coastal Zone, you may need a Coastal development Permit or an exemption. Contact
the Planning Department for details. A Coastal Zone map is part of this handout. If you are applying for a building permit in a
subdivision with a homeowner's association, you should secure architectural review prior to proceeding with the project. The City
does not enforce or specifically review provisions of homeowners' association CC&R's. HOA requirements may be different than
City requirements. If your home is part of a Planned Unit Development or a condominium, please see text of this handout.
Revised 10-3-96
1
2O75 Las Palmas Dr. - Carlsbad, CA 92OO9-1576 • (619) 438-1161 - FAX (619) 438-O894
TYPICAL R-1 PLOT PLAN
SETBACKS FOR R-1 PARCELS
FRONT YARD - 201 from front
property line
INTERIOR SIDE YARD - 10% of
tot width up to a maximum of
STREET SDE YARD-Iff
REAR YARD - 20% of lot width
up to maximum of 20 feet (Min.100
MAX. LOT COVERAGE - 40%
Contact the Planning Department
for information on comer tots or
lots with unusual configurations
and for information on Planned
Communities, accessory
structures, and building
heights.
The telephone number for the
Planning Department is
438-1161.
'I
20% of LOT
WIDTH TO A
MAX.OF201
STREET
LOT WIDTH MEASURED 20"
FROM 20' BACK OF
FRONT PROPERTY LINE
PROPERTY LINE
Minimum Square Footing Sizes (inches)1'2
Post
Spacing
4
6
8
-tflk.
12 )mr
16
18
20
6
12
12
12
12
12
12
12
12
14
8
12
12
12
12
12
12
14
14
14
10
12
12
12
12
14 (
14
14
16
16
Joist
Span
(feet)
12
12
12
12
<^L^
14 }
^tfr^
16
18
18
14
12
12
12
14
16
16
18
18
20
16
12
12
14
14
16
18
18
20
20
18
12
12
14
16
18
18
20
20
22
20
12
14
14
16
18
20
20
22
24
1. Assumes 1,000 psf soil bearing capacity
2. The minimum depth for all footings is 12 inches into natural grade
Patio Cover
Minimum Rafter Sizes
Rafter
Span
(feet)
6
7
8
9
10 i
^ J>P
12) iV^ ^
""* ^HW14 f]\C15 Vr Aj
16 ^ rfW
17 \u18 , \f
19 0V v^
20 1\p
Rafter Spacinq
12" (5/16" ply-
wood sheathing)
2X4
^^2_x4
2X**^
2x4 ^
2x6
2x6
2X6
2x6
2x6
2x6
2x8
2x8
2x8
2x8
2X8
Center to
(
16" (1/2° ply- \
wood
sheathing)
2x4
2x4
2x4
\ 2x6
^stg
2x6"\
2x6
2x6
2x6
2x8
2x8
2x8
2x8
2x10
2x10
^Center (inches)^S
24"j1/2" ply-
wood sheathing)
2x4
2x4
2x6
2x6
2x6
;£P*% N.
"NsN^2jLS-X
2"*^
2x8 \^
2x8
2x8
2x10
'2-.*3J9!t.:':'"'"i.
2x10
2x10
32" (5/8" ply-
wood sheathing)
2x4
2x4
2x6
2x6
2x6
2x8
2x8
2x8
2x8
\ 2x10
"\2x10
2~x-4£
2x10\^
2x12
2 x 12
X
Patio Cover
Minimum Beam Sizes
Post
Spacin
g (feet)
4
6
8
JH
3)
14
16
18
20
Rafter Span (in
feet)
4
4X4
4x4
4x4
4x4
4x6
4x6
4x8
4x8
4x8
6x8
6
.;:4-x4*<:
4x4
4x4
4x6
4x6
4x8
4x8
4x8
6x8
4x10
6x8
8
4x4
4x4
4x6
4x6
4x8
4x8
4x8
6x8
4x10
6x8
4x10
6x10
10
4x4
4x4
4x6
4x6
4x8
4x8
4x10
6 x 8
4x10
6x8
4 x 12
6X10
12
4x4
4x4
4x6
JJt£^
4 x 8J
4x8
6x8
4x10
6x8
4x10
6x10
4 x 12
6x10
14
4x4
4x4
4x6
4x6
4x8
6 x 8
4x10
6x8
4x10
6x10
4x12
6x10
4x14
6x12
16
4x4
4x4
4x6
4x8
'«P*8.:- ^
6x8
4x10
6x10
4 x 12
6 X 10
4x12
6x10
4x14
6x12
18
4x4
4x4
4 x 6
4x8
4x8
6x8
4x10
6x10
4x12
6x10
4x14
6x12
6x12
20
.4:xAm
4x6
4x6
4x8
4x10
6x8
4x10
6x10
4x14
6x10
4x14
6x12
6x14
TYPICAL PATIO COVER DETAILS
Flgura 1/Typteal patio construction
For ledger IDunit attachmentsee text
Post spacing
Continuoussolid blacking jbetween joists
more than 8* indepth
Figure 2/Connectbn, anchor and footing details
Case 1/Connection, end condition
7-0* minimum if required windowsbetween pabo and dwelling unit
See fooling details below
Case 2/Connection, interior condition
7 gauge steel V
strap, 2V,' wide
with four V* bolts.8" along beam.12" atony post
•I
•\S
Cast 3/Anchor and footing detail, integrated stab
7 gauge steel Tstrap 2'/,'wide -with 6 V.-O bolts
16'atengbeam,12'along post
Case 4/Anchor and footing detail, isolated pier
Post elevated1* minimumabove cono-Ke
Natural grade T.
Figure 3/Endosad patio section Figure 4/Endosed patio interior •lavation
7 to I A . Concreieslab
maximum mesh
,- insect screening or
' plastic screening
Nonbearingwall
-only between •
roof-supporting
members
PATIO COVER CONSTRUCTION SPECIFICATIONS
1. Concrete
a) All concrete for footings must be a minimum of 2,000 psi.
2. Lumber
a) Lumber must be Douglas Fir-larch No.2 or Better. Lumber must be grade marked. All posts
must be a minimum of 4x4 and may be required to be protected from decay and termites if
within 6" of finish grade.
3. Connections
a) Post anchorage may be accomplished with a standard manufactured post base installed per
the manufacturer's instructions. Footings are required when the post supports a load
exceeding 750 pounds. For lesser loads, a 3 Yi" slab on grade section may be substituted for
required footings.
b) When the house is used to support one end of the patio cover, the main beam may be
replaced on the side attached to the house by a ledger. The ledger shall be the same size as
the rafters and fastened to the structural frame of the house by Yi" x 5" lag screws spaced at
32" on center for rafters up to a 10' span. Lag screws must be spaced at 16" on center for
rafters between 10'1" and 20'. Rafters may not be solely supported by the existing rafter tails
or facia of the house.
4. Patio Enclosures
a) Patios may be enclosed as long as the following criteria is followed:
1) The enclosure walls may have any configuration provided the open area of the longer
wall and one additional wall is equal to at least 65% of the area below 6'8" of each
wall as measured form the floor (see City of San Diego Building Newsletter 31-
2) Openings may be enclosed with insect screening or plastic that is readily removable
translucent or transparent plastic not more than 1/8" in thickness. (See figures 3 and
4 above)
3) A patio enclosure requires a permit. The permit may be issued as part of the original
patio cover permit, or it may be obtained at a later time. Enclosures may be used for
outdoor recreational purposes only . Patio enclosures may not be used as habitable
space.
5. Tables
a) The above span and footing tables make the following assumptions:
1) Roof live load is 10 psf
2) Roof dead load is 7 psf
3) All lumber is Douglas fir-larch No.2 or Better;
Fb=825psi
Fv = 90 psi
E =1,200,000 psi
Repetitive member use
All posts are 4x4 minimum
Soil bearing pressure is 1000 psf minimum
6. Electrical
a) All electrical work in a patio cover or enclosure shall be weather tight as for exterior
installations.
7. Inspections
1) Normally two inspections of a patio cover are required:
1) When footings have been excavated but before concrete has been placed, (note:
photographs of footings are not an acceptable substitute for an inspection of required
footings).
2) When all structural framing is completed.
Note: The project is not legally complete until the inspector of record signs the space on
the job record card as final.
3) The job record card and approved plans must be available for all inspections. The job
record card and approved plans should then be retained by the owner as a record of
the approved construction.
8. Patio covers in PUD's and Condominium projects
a) All patio covers must comply with the above requirements.
b) Posts supporting the patio cover cannot be located closer than 3' to the property line
unless they are protected by one-hour construction (e.g. stucco)
c) The patio cover roof may only project one foot into the three foot setback area. It must
also have one hour protection as noted above.
d) Proof of HOA architectural approval must be shown.
e) For the property lines of a project, all applicable setback requirements for the underlying
zone shall be complied with. If the underlying zone is P-C, the setback requirements of
the PUD ordinance shall be complied with. Setbacks for PUD's and P-C Zones may be
more restrictive than typical R-1 setbacks or minimum Building Code setbacks. Contact
the planning Department for information specific to your Planned Community or
condominium project.
COASTAL COMMISSION
3111 CAMINO DEL RIO NORTH, STE. 200
SAN DIEGO, CA 92108
(619) 521-8036
•LOUVISTALAGOON
COASTAL ZONE
BOUNDARY
ENGR.-FEES MW4 PAGE: 28