HomeMy WebLinkAbout1350 CASSINS ST; ; CB080526; Permitf s,
04-30-2008
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
# Dwelling Units
Bedrooms
Project Title
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit Permit No CB080526
Building Inspection Request Line (760) 602-2725
1350CASSINSSTCBAD
RESDNTL Sub Type
2156902900 Lot#
$21,960 00 Construction Type
Reference #
0 Structure Type
0 Bathrooms
SCHILLING RES- CONVERT 180 SF
3RD CAR GARAGE TO OFFICE
RAD
0
NEW
Applicant
SCHILLING WILLIAM F&CHARY ALICE
1350CASSINSST
CARLSBAD CA 92011
760 804 9544
Status
Applied
Entered By
Plan Approved
Issued
Inspect Area
Ong PC#
Plan Check*
ISSUED
03/24/2008
LSM
04/30/2008
04/30/2008
Owner
SCHILLING WILLIAM F&CHARY ALICE
1350CASSINSST
CARLSBAD CA 92011
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
HMP Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$209 55 Meter Size
$0 00 Add'l Reel Water Con Fe?
$13621 Meter Fee
$0 00 SDCWA Fee
$0 00 CFD Payoff Fee
$220 PFF (3105540)
$0 00 PFF (4305540)
$0 00 License Tax (3104193)
$0 00 License Tax (4304193)
$0 00 Traffic Impact Fee (3105541)
$0 00 Traffic Impact Fee (4305541)
$0 00 Sidewalk Fee
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$0 00 MECHANICAL TOTAL
$0 00 Housing Impact Fee
$0 00 Housing InLieu Fee
$0 00 Housing Credit Fee
Master Drainage Fee
$0 00 Sewer Fee
$0 00 Additional Fees
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$2000
$2000
$000
$000
$000
$000
$000
$000
$000
$387 96
Total Fees $387 96 Total Payments To Date $387 96 Balance Due $000
•i^LDING PLANS
WL_ IN STORAGE
ATTACHED
Inspector Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, o. other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required imormation with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water -.nd sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees m connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave , Carlsbad, CA 92008
|#'. PROJECT INFORMAtlON--
FOR OFFICE USE ONLY
PLAN CHECK NO &&
EST VAL _*)) g
Plan Ck Deposi
Validated B
Date
'LSfa.
Address (include Bldg/Suite #)Business Name (at this address)
Legal Description Lot "No Subdivision Name/Numbere/Numb
—m
Unit No fcseNo Total # of units
Assessor's Parcel #ExistiftgJUse Proposed Usi
Description of Work /% / /f •* SQ FT
/^4 7~grf.<t?'Tfb*J e>7 £t*ty£t- (.4*
2.::!13CONTACT PERSON (if different from applicant)
#of Stories # of Bedrooms # of Bathroomsof Ba
V
Name
....^.^,, . .......
:3! APPLICANT
Address
............. .....
Contractor- Lj Agent for Contractor
City
Agent jfor Owner
State/Zip Telephone # Fax #
Name
4,v PROPERTY
Address Cif State/Zip Telephone #
Name / Address City State/Zip Telephone #
•: CONTRACTOR- COMPANY NAME " A; ; :
"(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
^issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500))
Name
State License #
Address
License Class
City State/Zip
City Business License tt
Telephone #
Designer Name Address City State/Zip Telephone
State License #
6. WORKEl^COMPENSATtON '.-:&>' "'"' Iftii-' ' • •"•! ' '.'••'- „ "'" "*'
Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
l~l I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued
PI I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued My worker's compensation insurance carrier and policy number are
Insurance Company Policy No Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
l~l CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California
WARNING Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100 000) in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney s fees
SIGNATURE DATE
V OWNER-BUILDER DECLARATION ;,;..; •:':-- " ' j %"•:••,: " :"""" '
I hereby affirm that I am exempt from the Contractor's License Law for the following reason
£Zj- I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)
|~l I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law)
l~l I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement l~1 YES (~lNO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number)
5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work) , , if
'ROPERTY OWNER SIGNATURE fr/-^ R/W ^~- ~) DATE
COMPLETE THIS SECTION f OK NON-RESIDENTIAL BUILDING PERMITS ONLY " '^2S"±.. • .. .. •.^MiMSSS.' llf if* ::: : '"i'-"::":
Is the applicant or future building occupant required to subrmt a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? (~l YES O NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES O NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? l~l YES l~l NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
8 CONSTRUCTION LENDING AGENCY • :?;>:?:
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code)
LENDER'S NAME LENDER'S ADDRESS
;9 .jIAPiPLiCANf CERTIFICATION " . as! •'•¥'•'! jii&sM:
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height
EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is commenced for a period of 180 days (Section 106 4 4 Uniform Building Code)
APPLICANT'S SIGNATURE DATE
WHITE File^ YELLOW Applicant PINK Finance
City of Carlsbad Bldg Inspection Request
For 12/04/2008
Permit* CB080526
Title SCHILLING RES- CONVERT 180 SF
Description 3RD CAR GARAGE TO OFFICE
Inspector Assignment PD
Sub Type RAD
1350 CASSINS ST
Lot
Type RESDNTL
Job Address
Suite
Location
APPLICANT SCHILLING WILLIAM F&CHARY ALICE
Owner SCHILLING WILLIAM F&CHARY ALICE
Remarks
Total Time
Phone
Inspector
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
7°
Requested By HOMEOWNER
Entered By CHRISTINE
Act -^Comments
Comments/Notices/Holds
Date
12/03/2008
06/18/2008
06/17/2008
06/17/2008
06/17/2008
Associated PCRs/CVs . Original PC#
Inspection History
Description Act Insp Comments
89 Final Combo
17 Interior Lath/Drywall
14 Frame/Steel/Bolting/Weldmg
17 Interior Lath/Drywall
34 Rough Electric
CA PD
AP PC NO CARD ON SITE TO SIGN
AP PD
WC PD
AP PD
EsGil Corporation
In (Partnership -with government for <Bui fifing Safety , .
DATE April 24, 2008 J3-A£EU£ANT
_
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 08-0526 SET II
PROJECT ADDRESS 135O Cassin St.
PROJECT NAME Garage Conversion for Bill Schilling Residence
XI The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
XI Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
REMARKS
By Sergio Azuela Enclosures
Esgil Corporation
E! GA D MB D EJ D PC 04/17/08
EsGil Corporation
In (Partnership with government for (BuiCding Safety
DATE March 31, 2008 OAEEUQANT
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 08-0526 SET I
PROJECT ADDRESS 1350 Cassin St.
PROJECT NAME Garage Conversion for Bill Schilling Residence
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
XI The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
XI The applicant's copy of the check list has been sent to
William F Schilling
1350 Cassin St, Carlsbad, CA 92011
Esgil Corporation staff did not advise the applicant that the plan check has been completed
XI Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted William F Schilling Telephone # (760) 804-9544
Date contacted ((l(0*(by/r-rP} Fax #
Mail ""Telephone^ Fax /''in Person
REMARKS (yX)
By Sergio Azuela Enclosures
Esgil Corporation
D GA D MB D EJ D PC 03/25/08
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 * Fax (858) 560-1576
Carlsbad O8-O526
March 31, 20O8
GENERAL PLAN CORRECTION LIST
JURISDICTION Carlsbad
PROJECT ADDRESS 1350 Cassin St.
DATE PLAN RECEIVED BY
ESGIL CORPORATION 03/25/08
REVIEWED BY Sergio Azuela
PLAN CHECK NO O8-0526
DATE REVIEW COMPLETED
March 31, 2008
FOREWORD (PLEASE READ)-
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and disabled access This plan review
is based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations The approval of
the plans does not permit the violation of any state, county or city law
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list If there are other changes, please briefly describe them and where
they are located on the plans Have changes been made not resulting from this list?
Q Yes a No
Carlsbad 08-0526
March 31, 2008
1 Please make all corrections, as requested in the correction list Submit three new
complete sets of plans for commercial/industrial projects (two sets of plans for residential
projects) For expeditious processing, corrected sets can be submitted in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments
2 Indicate on the Title Sheet of the plans the name of the person responsible for the
preparation of the plans Sec A106 1 1
3 Provide a statement on the Title Sheet of the plans, stating that this project shall comply
with the 2007 California Building Code, which adopts the 2006 IBC, 2006 UMC, 2006
UPC and the 2005 NEC
4 Please revise the section numbers and notes on the plans to match the 2006 IBC, as
adopted by California
5 Provide a fully dimensioned site plan drawn to scale Sec A106 1 1 Please include the
following
a) North arrow
b) Streets/alleys
6 Show locations of permanently wired smoke alarms with battery backup as follows
(Section 907 2 10 1 2)
a) Inside each bedroom
b) On the ceiling or wall outside of each separate sleeping area in the immediate
vicinity of bedrooms
c) In each story within a dwelling unit, including basements
• NOTE Where more than one smoke alarm is required to be installed within a unit,
the smoke alarms shall be interconnected in such a manner that the activation of one
alarm will activate all of the alarms in the unit Section 907 2103
7 Where an addition, alteration or repair to an individual dwelling unit or guestroom in
Group R requires a permit, battery-operated smoke alarms shall be installed in the
existing construction in accordance with the preceding item Section 907 21052
8 Show that ceiling height for habitable rooms and hallways is a minimum of 7'-6" Section
1208 2 Please show it on plans at the new proposed office
Carlsbad 08-O526
March 31, 2008
9 A foundation/soils investigation is required for all projects in Seismic Design Categories
C, D.EorF Section 1802 2
10 Provide a copy of the project soil report The report shall include foundation design
recommendations based on the engineer's findings
11 Show foundation bolt size and spacing Foundation bolt size and spacing for braced
walls must be clearly shown on the foundation plan
12 Sill plate size and anchorage. R33SHB1 Anchor bolts shall be provided with square
washers in accordance with Section 2305 311 Show the 3" square X 0 229" plate on
the plans
13 Show minimum under floor ventilation equal to a 1 sq ft for each 150 sq ft of under
floor area Openings shall be placed so as to provide cross ventilation of under-floor
space IBC, Section 1203 3
14 Show minimum 18 inch clearance from grade to bottom of floor joists and minimum 12
inch clearance to bottom of girders IBC, Section 2304 1121
15 Provide complete structural details on the plans with cross referencing as needed to
show the structural framing will comply with the design calculations and building code
requirements Section A106 1 1
16 Provide minimum structural specifications on the plans to show that ail structural
materials will comply with the design calculations and building code requirements
Section A106 1 1
17 Provide roof framing plan and floor framing plan Section A106 1 1 Please show it on
plans to show the bearing walls and also the tributary areas that are loaded over each
one of the walls and headers Additional corrections may follow
18 Specify on the plans the plywood grade and panel span rating IBC, Table 2304 7
19 Braced wall lines (Conventional construction) Buildings should be provided with
exterior and interior braced wall lines described in section 2308 9 3 in accordance with
Section 2308 3 1 through 2308 3 4
a) Spacing. Spacing of braced wall lines should not exceed 35 feet on center in both
the longitudinal and transverse directions in each story for SDC A, B and C
Section 2308 9 3 For SDC D and E, spacing of braced wall lines should not
exceed 25 feet on center (Sections 2308 12) See the figure below and address
the following specific problems
i) Please clearly show the shear walls over the entire perimeter of the new
office Please note that the minimum length shall be 12'
Carlsbad O8-O526
March 31, 2008
SEISMIC DESIGN CATEGORY
A, B and C
DandE
MAXIMUM WALL SPACING (feet)
35'-0"
25'-0"
REQUIRED BRACING LENGTH, b
Table 2308 9 3(1) and Section 2308 9 3
Table 2308 12 4
UP TO 4' 0"
OFFSET ALLOWED IN
BRACED WALL LINE
BRACED WALL
LINE NO 4 •
BRACED WALL LINE X
1218-MAX TO
FIRST BRACED
WALL PANEL
BRACED
WALL
LINE NO 1
BRACED
WALL
UNEY
BRACED
WALL
PANELS
BRACED
WALL UNE Z
BRACED WALL
UNE NO 2 DOES
NOT NEED TO
ALIGN WTTH NO 3
AS LONG AS IT
HAS A BRACED
WALL PANEL
AT EACH END
BRACED WALL LINE
NO 2
BRACED
WALL UNE
BRACED WALL
UNE NO 1 x
EXTERIOR
BRACED WALL
PANELS ARE
IN ONE PLANE
VERTICALLY
EXCEPT AS
PROVIDED FOR
IN SECTION
2308 126
NOTES
(1) SUM OF BRACED WALL PANEL
LENGTHS FOR BRACED WALL
UNE NO 1=<
UP TO 4'-<T
OFFSET ALLOWED IN
BRACED WALL UNE
CONTINUOUS
FOUNDATION AND
BRACED CRIPPLE
WALL RECOMMENDED
UNDER LOWER STORY
BRACED WALL PANELS
BRACED
WAU
PANELS - b
BRACED PANEL ABOVE MAY EXTEND UP TO
V 0- OVER WINDOW OR DOOR BELOW
I foot = 304 8 mm
FIGURE 2308 9 3
BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
Cfarlsbad O8-0526
March 31,. 2008
20 In Seismic Design Category D and E, braced wall panels (conventional construction)
shall comply with the following table Please address the following specific concerns
a) Please show it for the wall including the new opening
TABLE 2308 12 4
WALL BRACING IN SEISMIC DESIGN CATEGORIES D AND E
(Minimum Length of Wall Bracing per each 25 Linear Feet of Braced Wall Line*)
CONDITION
One story
Story below top story
[HCD 1]
Bottom story of three
stones [HCD 1]
SHEATHING TYPE"
G-F
S-W
a-p"
S-W
G-P
S-W
SOT<050
10 feet 8 inches
5 feet 4 inches
1 8 feet 8 inches'1
0.50s SDS<075
14 feet 8 inches
8 feet 0 inches
NP
10 feet 8 inches d \ 13 feet 4 inches d
0 75 S SQS S 1 00
18 feet 8 inches
9 feet 4 inches
NP
17 feet 4 inches'1
SBS > 1 00
25 feet 0 inches
12 feet 0 inches
NP
21 feet 4 inches'1
Conventional construction not permitted, conformance with Section 2301 2, Item lor 2 is
required
For SI 1 inch = 25 4 mm, 1 foot = 304 8 mm
a. Minimum length of panel bracing of one face of the wall for S-W sheathing or both faces of the wall for G-P sheathing, h/w ratio shall not exceed 2 1 For S-W
panel bracing of the same material on two faces of the wall, the minimum length is permitted to be one-half the tabulated value but the h/w ratio shall not exceed 2 1
and design for uplift is required
b G-P = gypsum board, fiberboard, particleboard, lath and plaster or gypsum sheathing boards, S-W = wood structural panels and diagonal wood sheathing NP =
not permitted
c Nailing as specified below shall occur at all panel edges at studs, at top and bottom plates and, where occurring, at blocking
For '/2-inch gypsum board, 5d (0 113 inch diameter) cooler nails at 7 inches on center,
For 5/8-mch gypsum board, No 11 gage (0 120 inch diameter) at 7 inches on center,
For gypsum sheathing board, P/4 inches long by 7/16-mch head, diamond point galvanized nails at 4 inches on center,
For gypsum lath, No 13 gage (0 092 inch) by 178 inches long, '\4-inch head, plasterboard at 5 inches on center,
For Portland cement plaster, No 11 gage (0 120 inch) by l'/2 inches long 7/16- inch head at 6 inches on center,
For fiberboard and particleboard. No 11 gage (0 120 inch) by 1 '/2 inches long, 7/16-mch head galvanized nails at 3 inches on center
d [HCD 1] Applies to detached one and two family dwellings only.
21 If Conventional Construction is not possible the applicant shall provide structural design
calculations
22 Show on the plans the location, type and size (BTU's) of all heating and cooling
appliances or systems
23 Show on the plan the amperage of the electrical service, the location of the service panel
and the location of any sub-panels If the service is over 200 amperes, submit a single
line diagram, panel schedules, and provide service load calculations
24 Provide plans, calculations or worksheets to show compliance with current energy
standards
25 The regulations require a properly completed and properly signed Form CF-1R (4 pages)
to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to
allow the building inspector to readily compare the actual construction with the
requirements of the approved energy design
26 Specify, on the building plans, that all of the mandatory energy features are indicated on
the plans and specifications or include a completed MF-1R form on the plans
27 Show the make, model, type and efficiency of the space heating (or cooling) system
Carlsbad 08-0526
March ,31,. 2008
28 Please revise the plans to show consistency, for example
a) The floor plan on sheet 3 indicated a 4040 window, instead of a 5040 as is
indicated on the first sheet and also on sheet 4
b) The floor plan on sheet 3 indicated that the room adjacent to the proposed
"Garage Conversion" is an Office while on sheet 6 the plan is showing the same
room as Bedroom 4
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the
plan review for your project. If you have any questions regarding these plan review
items, please contact Sergio Azuela at Esgil Corporation. Thank you.
CaVlsbad 08-O526
March 31, 2008
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad
PREPARED BY Sergio Azuela
BUILDING ADDRESS 135O Cassin St.
BUILDING OCCUPANCY R-3 & U
PLAN CHECK NO 08-0526
DATE March 31, 2008
Gar Conv /Schilling's Residence
TYPE OF CONSTRUCTION V-B
BUILDING
PORTION
Gar Conversion
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
RIHn Pprmif FPP hv Drrhna
AREA
(Sq Ft)
180
cb
Valuation
Multiplier
By Ordinance
nrp ! ^ i
Reg
Mod
VALUE ($)
21,960
21,960
$209 55
Plan Check Fee by Ordinance
Type of Review \2
] Repetitive Fee
Repeats
Complete Review
D Other
,—I Hourly
Structural Only
Hour*
Esgil Plan Review Fee
Comments
$13621
$11735
Sheet 1 of 1
macvalue doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB
ADDRESS
DATE
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
« $17,000.00)
OTHER
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
PLANNER
ENGINEER
DATE
DATE
Docs/Misforms/Plannmg Engineering Approvals
50 Q
s & sro ffl *QQ O Q
O OO fl)
6 O
J2 JS
DD
D D
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No CB
Planner
APN
Address
Gma Ruiz Phone (760) 602-4675
Type of Project & Use
Zoning p-£/ General Plan
CFD (in/out) #_Date of participation
Net Project Density DU/AC
Facilities Management Zone _
Remaining net dev acres
Circle One
(For non-residential development Type of land used created by this
permit )
Legend: ^ Item Complete Q Item Incomplete - Needs your action
Environmental Review Required YES NoX TYPE
DATE OF COMPLETION
Compliance with conditions of approval? If not, state conditions which require action
Conditions of Approval
Discretionary Action Required.
APPROVAL/PESO NO
PROJECT NO
YES
DATE
NO TYPE
OTHER RELATED CASES
Compliance with conditions or approval? If not, state conditions which require action
Conditions of Approval
nn
n n
n n
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES
CA Coastal Commission Authority? YES.
NO
NO V
If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103,
San Diego CA 92108-4402, (619) 767-2370
Determine status (Coastal Permit Required or Exempt)
Habitat Management Plan
Data Entry Completed? YES NO A
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and
assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type
impacted/taken, UPDATE')
Inclusionary Housing Fee required YES NO X
(Effective date of Inclusionary Housing Ordinance - May 21, 1993 )
Data Entry Completed? YES.NO
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATE')
H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06
Srte_Pl
^Provide a fully dimensional site plan drawn to scale JShow North arrow, property lines, easements,
"existing and proposed structures, streets,1—existing street improvements, right-of-way width,
dimensional setbacks and existing topographical lines (including all side and rear yard slopes)
Provide legal description of property and assessor's parcel number
Policy 44 - Neighborhood Architectural Design Guidelines
XD 1 Applicability YES NO_
D 2 Project complies YES NO_
D
n
n n
Zoning
1 Setbacks
Front
Interior Side
Street Side
Rear
Top of slope
M/A
Required
Required
Required
Required
Required
2 Accessory structure setbacks
Front
Interior Side
Street Side
Rear
Structure separation
3 Lot Coverage
4 Height
5 Parking
Required
Spaces Required
Shown
Shown
Shown.
Shown
Shown
Required
Required
Required
Required
Required
Required
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown II
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required _ Shown _
Additional Comments A
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE
H^ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06
y**Dv*0
fo1
O
fl
Go
^T
-£
§~
S f8
Is
o i-
> !Z-x-z.o «> X)^ m
£^m O
°1
^O ->.mg
en
S
O)
CO
3
S
COc/>
CO
!Q
I
nais§
»•
anS
I
O
O
I
!
nn
M?
m
n
-O
^^
C a,