Loading...
HomeMy WebLinkAbout1360 FOREST AVE; ; CB151335; Permit' City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 06-24-2015 Patio/Deck Permit Permit No: CB151335 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: 1360 FOREST AV CBAD PATIO Status: Lot#: 0 Applied: Valuation: 1560521400 $5,500.00 Construction Type: NEW Entered By: Reference #: Plan Approved: Issued: Inspect Area: Plan Check#: Project Title: WALKER RES= ADD 280 SF BALCONY I RELOCATE WINDOWS, NEW DOOR@ BALCONY// MINOR GAS & ELECT, REPLACE ELECT PANEL Applicant: TODD KUHLMAN 1336 CAMINITO SEPTIMO CARDIFF CA 92007 760-277-3582 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Strong Motion Fee Green Bldg Standards (SB1473) Fee Renewal Fee Add'I Renewal Fee Other Building Fee Additional Fees TOTAL PERMIT FEES Owner: WALKER HEATH&SHANNON 1360 FOREST AVE CARLSBAD CA 92008 ISSUED 05/01/2015 LSM 06/24/2015 06/24/2015 $78.91 $0.00 $55.24 $50.00 $1.00 $1.00 $0.00 $0.00 $70.00 $0.00 $256.15 Total Fees: $256.15 Total Payments To Date: $256.15 Balance Due: Inspector: Clearance: $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as '1ees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020{a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any f e reviou I been i e i ilartol i ·ch the t lute Ii it Ii ns · us th i eex · THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: OPLANNING 0ENGINEERING 0BUILDING OFIRE OHEALTH 0HAZMATIAPCD ~ «.t"r ~ CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www.carlsbadca.gov SUITEt/SPACEt/UNITJ Plan Check No. Est. Value I'+ 000 Plan Ck. Deposit Date S-: , ,!S SWPPP APN l 5(... -cs:F;, PHASE# # OF UNITS # BEOROOMS # BATHROOMS TENANT BUSINESS NAME 7:, 2-- PROPERTY OWNER ADDRESS CONTRACTOR BUS. NAME ADDRESS ADDRESS ~ CITY STATE ZIP CITY STATE ZIP PHONE FAX PHONE FAX EMAIL EMAIL STATE LIC.# CLASS CITY BUS. LIC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a per ·t to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law /Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exemP.t therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars t,500}). WORKERS' COMPENSATION Wor1'.ers' Compensation Declaratlon: I hereby affirm under penalty of petjury one of the following declarations: B I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Seciion 3700 of the Labor Code, for the performance of the work for which this pennit is issued. I have and will maintain woril.ers' compensation, as reQuired by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. Polley No. Expiration Date---------- ~section need not be completed if the permit is for one hundred dollars ($100) or less. LJ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure woril.ers' compensation coverage Is unlawful, and shall subject an employer to crtminal penalties and clvll fines up to one hundred thousand dollars {&100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, Interest and attorney's fees. I hereby affirm that I am exempt from Contractor's License Law for the following reason: D D D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contrac~ng with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0Yes 0No 2. I (have I have not) signed an application for a building pe i or proposed work. 3. I have contracted with the following person (firm) to P.ro 4. I plan to provide portions of the work but I hav i 5. I will provide some of the wor ut. I ha sed construction (include name address I phone f contractors' license number): n to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number): ng persons to provide the work indicated (include name I address I phone/ type of work): ,65 PROPERTY OWNER SIGNATURE DATE ~t'l.4-15 COMPLETE THIS SECTION FOR NON-Rl!SIDl!NTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business p~an lely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes No ~ Is the applicant or future building occupant required to obtain a permit from pollution control district or air~u · anagement district? Yes <.J:&_....J Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes N IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UN THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certify that I have read the application and state that the above lnfonnation Is cxmectand that the information on the plans Is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize rei:resentative of the City of Carlsboo enter n the atxlve mentbned property br inspectbn purposes. I ALSO AGREE TO SAVE, INDEMNIFY /I.ND KEEP HAAMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS S WHICH MAY IN AAY WAY ACCRUE AGAINST SAID CITY IN C~SEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: AA OSHA i;ermlt is requ· demolltbn or construction of structures over 3 stories 11 he'ijht. EXPIRATION: Every permit· p · k:lns of this C.oc1e shall expire by limitation and beoome null and voi:I Wthe buikling or Yak authorized by such permit is notcommenca:l 'Mthin 180 days from the date of s · by such permit is suspended or abandoned al any time after the 'Mlfk is rommenca:l r a period f 180 days (Section 100.4.4 Unifonn Building C.ocie). ,@S' APPLICANT'S SIGNATURE DATE + i STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-.8560, Email building@carlsbadca.gov or Mail the completed form to City of Car1sbad, Building Division 1635 Faraday Avenue, Car1sbad, California 92008. CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. UC. No. DELIVERY OPTIONS PICK UP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg . .1) MAIL TO: CONTACT (Listed above) CONTRACTOR (On Pg . .1) OCCUPANT (Listed above) MAIL/ FAX TO OTHER: _______________ _ .L APPLICANT'S SIGNATURE ASSOCIATED ce,, ____________ _ NO CHANGE IN USE/ NO CONSTRUCTION CHANGE OF USE/ NO CONSTRUCTION DATE ZIP Inspection List Permit#: CB151335 Type: PATIO WALKER RES= ADD 280 SF BALCONY I RELOCATE WINDOWS, NEW Date lm,pection Item Inspector Act Comments 05110/2016 89 Final Combo RI 05/10/2016 89 Final Combo PD AP 11/20/2015 84 Rough Combo PD AP 11/13/2015 14 Frame/Steel/Bolting/Weldin PB AP 11/03/2015 34 Rough Electric PD AP 07/22/2015 11 Fig/Foundation/Piers PD AP Tuesday, May 10, 2016 Page 1 of 1 EsGil Corporation In <Partnersnip witn government for (!Jui(aing Safety DATE: JUNE 18, 2015 JURISDICTION: CARLSBAD PLAN CHECK NO.: 15-1335 PROJECT ADDRESS: 1360 FOREST AVENUE SET: II 0 APPLICANT 0 JURIS. 0 PLAN REVIEWER 0 FILE PROJECT NAME: WALKER SFR -BATHROOMS REMODEL & PANEL UPGRADE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. k2:] The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: TODD k2:] EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: TODD KUHLMAN Telephone#: 760-277-3582 Date contacted: (by: ) Email: kuhlman@methodoloqy360.com Mail Telephone Fax In Person [2'.] REMARKS: Specify on plans: New water closets shall use no more lhan 1.28 gallons of water per flush, lavatories are limited to 1.5 GPM, and showerheads may not exceed 2.0 GPM offiow. CPC Section 403 and 408. '[Scope of work was modified at back-check to delele the patio/ deck & fireplace, instead remodel the baths & upgrade the panel]. By: ALI SADRE, S.E. Enclosures: EsGil Corporation D GA D EJ D MB D PC 6/16 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In <Partnersfiip witfi C}ovemment for (}Juifd'ing Safety DATE: MAY 08, 2015 JURISDICTION: CARLSBAD PLAN CHECK NO.: 15-1335 PROJECT ADDRESS: 1360 FOREST AVENUE SET: I D_.,APPLICANT ~ JURIS. 0 PLAN REVIEWER D FILE PROJECT NAME: WALKER SFR -DECK/ PATIO & FIREPLACE ADDITION D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: TODD D EsGil Corporation staff did not advise the applicant that the plan check has been completed. ~ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: TODD KUHLMAN _})ate conJacted:f: { 0 (by~ ~ail Aelephone Fax In Person D REMARKS: By: ALI SADRE, S.E. EsGil Corporation D GA D EJ D MB D PC 5/04 Telephone#: 760-277-3582 Email: kuhlman@methodology360.com Enclosures: 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 CARLSBAD 15-1335 MAY 08, 2015 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 15-1335 JURISDICTION: CARLSBAD PROJECT ADDRESS: 1360 FOREST AVENUE FLOOR AREA: DECK = 280 PATIO= 338 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 5/01 DATE INITIAL PLAN REVIEW COMPLETED: MAY 08, 2015 FOREWORD (PLEASE READ): STORIES: ONE HEIGHT: 14' DATE PLANS RECEIVED BY ESGIL CORPORATION: 5/04 PLAN REVIEWER: ALI SADRE, S.E. This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2013 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC, 2012 UPC, 2012 UMC and 2011 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. CARLSBAD 15-1335 MAY 08, 2015 • PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2013 California Residential Code, which adopts the 2012 IRC, 2012 UMC, 2012 UPC and the 2011 NEC. Section R106.1. • FIRE PROTECTION 4. Show locations of battery operated smoke alarms, per Section R314: a) Inside each existing bedroom. b) Outside each separate sleeping area in the immediate vicinity of the bedrooms. c) On each story. • NOTE: When more than one smoke alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all. 5. Show the locations of battery operated carbon monoxide alarms, per Section R315: a) Outside each separate sleeping area in the immediate vicinity of the existing bedrooms. b) On each story. • NOTE: When more than one carbon monoxide alarm is required to be installed, the alarm devices shall be interconnected such that the actuation of one alarm will activate all. • ROOFING 6. Specify roof material and application. Chapter 9. This is to meet min. Class "A" roofing material fire rating. 7. Specify roof slope on the plans. 8. Specify minimum Y. inch per foot deck slope for drainage. Section R905.9.1. CARLSBAD 15-1335 MAY 08, 2015 • STRUCTURAL 9. Please show complete & legible details and references for the patio cover. 10. Please provide complete structural framing plans, identifying all member sizes and connection details with references on plans for the covered patio. What is shown on Sheet A3.0 is not adequate for this purpose. See the next item too. 11. Provide connection details and references for columns to footings, beams to posts, hip beams to ridge beam, etc. 12. Specify nail size and spacing for the roof diaphragms on the plans. Table R602.3(1). Specify plywood and/or particle board thickness, grade and panel span rating. Table R503.2.1 (1) 13. Please provide calculations for the proposed members of the patio cover. 14. Per Figure 1609A, the wind load calculations must use an ultimate wind speed of 110mph. 15. If there is a Masonry Fireplace as noted on plans, show complete details & references or include County Standard Details with references on plans. 16. The plans shall indicate that special inspection will be provided for the following work. (CBC Chapter 17 and Section 107.2): a) Epoxy Anchors. Periodic special inspection should be provided for anchors installed in hardened concrete. Section 1705.3. This applies to any connections to existing footings. 17. Show connection details and references on plans between the new & existing construction. This applies both at the foundation & at plate line (roof line). • MECHANICAL 18. Specify on the plans the following information for the fireplace: This applies if there is a prefabricated fireplace as noted on plans: a) Manufacturer's name/model number and ICC approval number, or equal. b) Show the height of the factory-built chimney above the roof and the horizontal clearances per listing approval. Chimneys shall extend at least 3' above the highest point where it passes through a roof and at least 2' higher than any portion of a building within a horizontal distance of 10 feet. CMG Section 802.5.4. c) Note on the plans that approved spark arrestors shall be installed on all chimneys. CRC Section R1003.9. d) Decorative shrouds shall not be installed at the termination of chimneys for factory-built fireplaces, except where such shrouds are listed and labeled for use with the specific system and installed in accordance with the manufacturer's installation instructions. Section R1004.3. • ELECTRICAL 19. Show on the plan the location & amperage of the electrical service. <::ARLSBAD 15-1335 MAY 08, 2015 20. Note on plans that receptacle outlet locations will comply with CEC Art. 210.52. 21. Include the following electrical notes on plans: a) Tamper resistant receptacles for all new locations. NEC 210.52. b) Weather resistant type for receptacles installed in damp or wet locations (outside). 22. A deck, or porch that is greater in area than 20 square feet and is accessible from the interior of the dwelling will require a minimum of one receptacle outlet. CEC 210.52(E). This receptacle must be GFCI protected. • ENERGY CONSERVATION 23. Residential energy lighting requirements: ES 150.0(k): • Outdoor lighting fixtures that are attached to a building are required to be high efficacy or be controlled by a combination photo-control/ motion sensor. 24. Fenestration alterations must meet all requirements of Energy Standards (ES 150.1) and Table 150.1-A except: • 75 sq. /ft. square feet may be added and not be required to meet the total fenestration or west facing fenestration maximum areas. • Replacement of existing fenestration up to 75 sq. /ft. only needs to meet the U-factor of .40 and SHGC of .35 specifications, not the Table 150.1-A specification values. • "Replacement" windows are windows in the same location and size of the existing. If an existing window is moved to a new location, it is a "new" window. • MISCELLANEOUS 25. Provide a note on plans stating: "New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast in color to background. Numbers shall be a minimum of 4" high with a minimum stroke width of Yi inch." CFC Sec. 505.1. 26. To speed up the review process, note on this list where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 27. The jurisdiction has contracted with EsGil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact ALI SADRE, S.E. at EsGil Corporation. Thank you. , CARLSBAD 15-1335 MAY 08, 2015 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PLAN CHECK NO.: 15-1335 PREPARED BY: ALI SADRE, S.E. DATE: MAY 08, 2015 BUILDING ADDRESS: 1360 FOREST AVENUE BUILDING OCCUPANCY: R3/U; V-B BUILDING PORTION DECK PATIO ~1K1::PLAGI:: Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code Type of Review: D Repetitive Fee ~ Repeats AREA Valuation ( Sq. Ft.) Multiplier 280 338 1 CB By Ordinance Complete Review D Other 0 Hourly EsGil Fee Reg. VALUE ($) Mod. o Structural Only 1-----~1Hr. @ * 14,000 $150.07! $97.551 $84.041 Comments: Sheet 1 of 1 «~ ~ CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK REVIEW CHECKLIST P-28 DATE: 6-17-15 PROJECT NAME: PROJECT ID: Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www .carlsbadca.irnv PLAN CHECK NO: CB 15-1335 SET#: 2 ADDRESS: 1360 Forest Av APN: 156-052-14-00 ~ This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Sexton A Final Inspection by the Planning Division is required D Yes C8'.] No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: kuhlman@methodology360.com For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 ~ Chris Sexton D Chris Glassen D Greg Ryan 760-602-4624 760-602-2784 760-602-4663 Chris.Sexton@carlsbadca.gov Christo12her.Glassen@carlsbadca.gov Gregory.Ryan@carlsbadca.gov D Gina Ruiz D ValRay Marshall D Cindy Wong 760-602-4675 760-602-27 41 760-602-4662 Ginsi.Buiz~i;sirl~bsi!:li;si.g2v Va1Ray.Mar~hal1@carlsbadca.gov .C..W.thia.Wong@carlsbadca.gQv D D Linda Ontiveros D Dominic Fieri 760-602-2773 760-602-4664 linda.Ontiveros@carlsQ.adc~_,_gov Dominic.Fieri@carlsbadca.gov Remarks: REVIEW#: 1 2 3 ~DD ~DD ~DD ~DD ~DD ~DD P-28 PlanCheckNo.CB15-1335 Address1360ForestAv Date6-17-15 Review#£ Planner Chris Sexton Phone (760) 602-4624 APN: 156-052-14-00 Type of Project & Use: patio covers Net Project Density:1.0 DU/AC Zoning: R-1 General Plan: RLM Facilities Management Zone: 1 CFD (in/out) #_Date of participation: __ Remaining net dev acres: __ (For non-residential development: Type of land use created by this permit: __ ) Legend: ~ Item Complete Environmental Review Required: D Item Incomplete -Needs your action YES D NO D TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES D NO D TYPE __ APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: __ Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES D NOD CA Coastal Commission Authority? YES D NO D If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Habitat Management Plan Data Entry Completed? YES D NO D If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) lnclusionary Housing Fee required: YES D NOD (Effective date of lnclusionary Housing Ordinance -May 21, 1993.) Data Entry Completed? YES D NO D (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) Housing Tracking Form (form P-20) completed: YES D NOD N/A D Page 2 of 3 07111 Site Plan: [g1 D D [g1 DD [g1 DD [g1 DD [g1 DD [g1 DD Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. City Council Policy 44 -Neighborhood Architectural Design Guidelines 1 . Applicability: YES O NO 0 2. Project complies: YES O NOD Zoning: 1 . Setbacks: attached to side yard Front: Required 20' Shown 20' Interior Side: Required 8.4' Shown 8.4' Street Side: Required __ Shown __ Rear: Required 16.8' Shown 16.8' Top of slope: Required __ Shown __ 2. Accessory structure setbacks: 338 sq ft detached patio cover Front: Required 20' Shown 20' Interior Side: Required §'. Shown 10'7" Street Side: Required N/A Shown NIA Rear: Required§'. Shown 16'3" Structure separation: Required 1Q'. Shown 11'5" 3. Lot Coverage: Required <40% Shown 24% 4. Height: Required <24' with less 3:12 roof pitch Shown 12'5 Y," 5. Parking: Spaces Required.?. Shown .?. (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required __ Shown __ Additional Comments 1) The detached patio cover cannot exceed 14' with a min. 3:12 roof pitch. The dimension on sheet A4.0 on the west elevation exceeds 14 feet. 6-17-15 per the architect, the detached patio cover and fireplace are being removed from this permit. . OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER Chris Sexton DATE 6-17-15 P-28 Page3of3 07/11 Re: !366 forest ave Re: 1360 forest ave From: Heath Walker Sent: Fri, May 1, 2015 at 12:28 pm To: methodology360 Cc: building@carlsbadca.gov Todd, Page I of I RECORD COPY I give you full permission to approve and sign to the city of carlsbad for the permits requested on our property at: 1360 Forest Ave carlsbad CA 92008 Thanks Heath Walker Stance International Director EMEA&ANZ Cell// +17608453306 www.stance.com @stancesocks @stance_muse On May 1, 2015, at 12:26 PM, methodology360 <kuhlman@methodology360.com> wrote: Heath, Please reply all to include the City of Carlsbad building department with a statement that you are the owner of the house at 1360 Forest Ave and that you authorize Todd Kuhlman to sign the permit application for the exterior modifications as the owner-builder on your behalf. Thanks, Todd Kuhlman methodology360 Sent from my iPhone 760.277.3582 http://webmail.emailsrvr.com/versions/webmail/l l .5.2-RC/popup. php?wsid=04fa6ddftl06f... 6/24/2015