Loading...
HomeMy WebLinkAbout1367 CYNTHIA LN; ; CB891990; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 05-04-2009 Building Permit Permit No CB891990 Building Inspection Request Line (760) 602-2725 Job Address 1367 CYNTHIA LN CHAD Permit Type SFD Sub Type Parcel No 1562306400 Lot # Status EXPIRED Valuation $0 00 Const Type VN Applied 12/27/1989 OccGroup R3 Reference # Entered By DC Appr/Issued Project Title 2S 2442 SF + 650 SF BASEMENT Inspect Area GAR 552, WRKSHOP 504 Applicant Owner WICKHAM, CLYDE WICKHAM, JULIE & CLYDE 1365 CYNTHIA LN CARLSBAD, CA 92008 619 439-5547 Total Fees $603 00 Payments To Date $603 00 Balance Due $0 00 Description Fee Other 603 00 FINAL APPROVAL Inspector Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION City of Carlsbad Building Department 2075 Las Palmas Dr , Carlsbad, CA 92009 (619) 438-nsi L PERMIT TYPE ( ~A O COMMERCIAL QJNEW Q TENANT IMPROVEMENT B D INDUSTRIAL D"EW QTENANT IMPROVEMENT c ^[RESIDENTIAL DAPARTMENT QCONDO QSINGLE FAMILY DWELLING ODDI-HON/ALTERATION QDUPLEX DDEMOLITION DISLOCATION nMOBILE HOME DELECTRICAL QPLUMBING QMECHANICAL Ofoo\. DSPA DETAINING WALL DSOLAR PROJECT INFORMATION PLAN CHECK No EST VAL PLAN CK DEPOSIT VALID BY U ^~ , DATE 2302 .12/27/89 0001 03 02 C.-PRMT 603-00 FOR OFFICE USE ONLY Nearest Cross streets Building or Suite" No' LEGAL DESCRIPTION ^~>. Lot No Subdivision Name/Number ji. Unit No Phase NoYAflcew f^ VUNOKSOB.* CHECJC BELOW IF SUBMITTED W2 Energy Calcs Q2 Structural Calcs ASSESSOR'S PARCEL [H2 Soils Report d 1 Addressed Envelope EXISTING USE PROPOSED USE DESCRIPTION Or UORK BLDG SO FTG *# OF STORIES * 3 CONTACT PERSON ADDRESS 4 5 6 S-GNATURE 0 ^iA^ . APPLICANT V V D CONTRACTOR NAME PROPERTY OWNER NAME CONTRACTOR NAME CITY Ci n AGENT STATE OWNER STATE STATE Cu TO?O& FOR CONTRACTOR QOWNER ADDRESS ZIP CODE ADDRESS ZIP CODE ADDRESS ZIP CODE C.IrwrilM oR^51-w^r7 D AGENT FOR OWNER DAY TELEPHONE OLESSEE DAY TELEPHONE DAY TELEPHONE Q TENANT STATE LIC #LICENSE CLASS CITY BUSINESS LIC # SIGNATURE DESIGNER NAME CITY 7 WORKERS 'COMPENSATION TITLE ADDRESS STATE ZIP CODE DATE DAY TELEPHONE STATE LIC # Workers' Compensation Declaration I hereby affirm that I have a certificate of consent to self insure issued by the Director of Industrial Relations or a certificate of Workers Compensation Insurance by an admitted insurer or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800 Lab C) INSURANCE COMPANY POLICY NO EXPIRATION DATE Certificate of Exemption I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California SIGNATURE DATE 8 OWNER-BUILDER DECLARATION Owner Builder Declaration I hereby affirm that I am exempt from the Contractor's License Law for the following reason I I 1 as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale ) II I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) f~l I am exempt under Section Business and Professions Code for this reason more than five hundred dollars [S500]) SIGNATURE DATE COMPLETE THIS SECTION FOR NON RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act' DYES QNO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' DYES DNn Is the facility to be constructed within 1 000 feet of the outer boundary of a school site' \3m IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT CONSTRUCTION LENDING AGENCY 1 hereby affirm that there is a construction Lending agency for the performance of the work for which this permit is issued (Sec 3097( i ) Civil Code) LENDER'S NAME LENDER'S ADDRESS 10 APPLICANT'S SIGNATURE _ __ I certify that I have read the application and state that the above information is correct I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes 1 ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT Expiration the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building s not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended work is commenced for a period of 180 days (Section 303(d) Uniform Building Code) WNER Q] CONTRACTOR APPROVED BY DATE WHITE File YELLOW Applicant PINK Finance DATE: 12/03/90 TO- WICKHAM, CLYDE 1365 CYNTHIA LANE CARLSBAD, CA 92008 PLAN CHECK EXPIRATION PC# CB891990 DATE: 12/27/90 ADDRESS: 1367 CYNTHIA LN You have applied to have your plans checked on the date shown above, and you have not obtained your building permit. The provisions of Section 304(d) of the Uniform Building Code state: "Section 304(d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official. In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee." Please check the appropriate box indicating your choice and return this letter to the BUILDING DEPARTMENT. PROJECT ABANDONED PROJECT ABANDONED I WILL PICK UP PLANS WITHIN 10 DAYS PLANS MAY BE DESTROYED. If you have any questions, please contact the Building Department at (619) 438-1161. DORIS COSMAN Building Department City of Carlsbad TO June 1, 1990 Clyde Wickham 1365 Cynthia Lane Carlsbad, CA 92008 Building Department S9~1990 DATE 12/27/89 PLAN CHECK EXPIRATION Our records indicate that you have not obtained your building permit for which you filed an application on the date shown above The provisions of Section 304(c) of the Uniform Building Code state Section 304(c) Expiration of Plan Check Application for which no permit is issued within 180 days following the date of application shall expire by limitation and plans submitted for checking thereafter be returned to the applicant or destroyed by the Building Official The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant showing that circumstances beyond the control of the applicant have prevented action from being taken In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan check fee For your convenience, please check the appropriate box below indicating your intentions and return this letter to the address above Project abandoned. I will pick up plans within 10 days Signature Date Project abandoned, plans may be destroyed Signature Date ^C Maximum 180-day time extension requested for the following reasons \ VDate Oil* 1 If you have any questions, please contact the Carlsbad Development Processing Section at (619) 438-1161 DORIS COSMAN Building Department 2O75 Las Palmas Drive •Carlsbad, California 92OO9~4859»(619) -438-1161 C a t y ofCarlsbad ' Sr Cff?^P99ISSS!mK^^H3nKnmnVBVn9HDHHPtlW!^H^^HHm^BVIGo m m u n i ty^ Deve I o p men t DATE juen 10, 1990 Clyde Wickham 1365 Cynthia Lane Carlsbad, CA 92008 RE PLAN CHECK EXTENSION PC# 89-1990 In answer to your request of , an extension has been granted to 12/27/90 Section 304 (d) of the 1985 Uniform Building Code prohibits any further extension of time MARTIN QRENYAK Director Community Development MO dc 2O75 Las Palmas Drive • Carlsbad California 92OO9 - (619) 438-1161 ESGIL CORPORATION 9320 CHESAPEAKE DR , SUITE 2O8 SAN DIEGO, CA 92123 (619) 560-1468 DATE n ) )' \ICTION ( ^ ^ ISt^ato* HECK NO ^9- /99^ T ADDRESS /C_T £? X* T NAME • <S f- fj \ cw67 SET hfli/^ 7TT~ / « [J APPLICANT fBTIJ RI ggl CTTDN LjPLAN CHECKERCOPY QUPS r DESIGNER D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's ^building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corp. until corrected plans are submitted for recheck D The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person [[ The applicant's copy of the check list has been sent to Esgil staff did not advise the applicant contact person that Ian check has been completed. II Esgil staff did advise applicant that the plan check has — been completed. Person contacted- Date contacted: REMARKS Telephone # ir A-g? >^1 ^ ~t-±JL ~) rr-7^_^*-*r-vL* j ~E^Enclosures: CORPORATION DGA DAA Dvw ESGIL CORPORATION 9320 CHESAPEAKE DR , SUITE 2O8 SAN DIEGO, CA 92123 (619) 56O-1468 DATE.7 JURISDICTION djZtSU'^f PLAN CHECK NO PROJECT ADDRESS PROJECT NAME (~l APPLICANT QPLAN CHECKER QFILE COPY QUPS nDESIGNER The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information plans are being held at Esgil Corp. until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person The applicant's copy of the check list has been sent to Ic^/c Esgil staff did not advise the applicant contact person that plan check has been completed Esgil staff did advise applicant th -been completed Person contacted. he/plan chec/c has U I < & if- Date contacted. Q REMARKS: Telephone ;GIL coRpa DGA DAA Dvw JURISDICTION Da t PROJECT ADDRESS TO C. XL LL PLAN CORRECTION SHEET FOREWORD- PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The items circled below need clarification, modification or change. All circled items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec 303 (c), of the Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A. PLANS 1. iPlease make all corrections on the original — ^ tracings and submit two new sets of prints, and any original plan seta that may have been retted to^ you j>y\the jurisdiction,= tu*ned to^ you bf\l ^ ^O. / / (_ J ^/ // /To facilitate rechccking, please identify, next to each circled itc-n, the sheet of the plans upon which each correction on tMs sheet has been made and return this check sheet vith the revised plans. Date The following items have not been resolved from previous plan reviews The original correction number has been given for your reference Please contact me if you have any questions regarding these items _.. j plans received by plan checker ?plan ck ^2^i/ ^ 1 7~4x_ ^l!w/t^\ /i-<*-~vss. r~£ A-V7 <? / n '/vvr-*»3/ ~~7JA-£o^/^f *L.*A. i<^+-. 1 T^- -^ I/ <3 c\. ls\*sr u f O'£^L<-<z,~77f?+i<z z? /^ c< ^ c2 C^_^r // >^^7 -^ /^ ../_ ^, / ^ ^-7^7 /^ / Of&ft » -j g ^// ^/ ^ y <v $^. (^/o" ^ * f / f / ~7 7 . f^ ^ //."?. / VY / £tt s / / i m o-*i_^f / /\^> I-P fD^-hrO / <T T^ ^7«^_ ^ Ga-P/^J W£^ ^.U^> i*J **^^ -&s\ r^o^/^-**? /j?1 *° •^^''7-^. ^ / ^^y , / x / ~X>/>!^/ ^/k< X /^/ / XT L/ ^T • A . — ' — ] / ESGIL CORPORATION 9320 CHESAPEAKE DR , SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE JURISDICTION. (\ PLAN CHECK NO (ya&t. 8? 'SET PROJECT ADDRESS PROJECT NAME • Cv/ H~~/ U t _/i APPLICANT JURISDICTI( jLAN CHECKER QFILE COPYQUPS nDESIGNER D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's D building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information \ The plans are being held at Esgil Corp. until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to C* I yo\J? UJt c,ci. he*. rv\_ / v5 fa £~ d\jh~t-L j*. L Esgil staff did not advise the applicant contact person that plan check has been completed I I — Esgil staff did advise applicant that the been completed. Person contacted- Q,(i/e«.f- cKe.ek has Date contacted: REMARKS: Telephone Enclosures; SSGIL CORPORATION lA-SLtj-WrfDGA DAA Dvw TJDM PLAN CHECK NO. JURISDICTION: ( gy/M- TO. ENCLOSURES: PROJECT ADDRESS: FLOOR AREA: HEIGHT: REMARKS: FLAN COKkta.rj.iOH SINGLE FAMILY AND DOPLBC DWELLINGS FOREWORD PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped The plan check is based on regulations enforced by the Building Inspection Department You may have other corrections based on laws and ordinances by the Planning Department, Engineering Department or other departments Present California law mandates that residential construction comply with Title 24 and the following model codes 1985 UBC (eff 7/31/87) 1985 UPC (eff 3/30/87) 1987 NEC (eff 10/28/87) 1985 UMC (eff 8/28/87) The above regulations construction, regardless adopted by ordinance apply to residential of the code editions The circled items listed need clarification, modification or change All items have to be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 303(c), 1985 Unfonn Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed i e . plan sheet, specification, etc Be sure to enclose the marked up list when you submit the revised plans Date plans received by jurisdiction Date plans received by Esgil Corporation Applicant contact person NOTE: Telephone FAGS NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO HEMS HEEDING CORRECTIONS WERE DELETED. List No 60, General Single Family Dwelling and Duplex Without Supplements (1985 UBC) 9 O Q o© PLANS Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, California 92123, (619) 560-1468 Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to The jurisdiction's building department Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans Section 302(a)7 All sheets of plans must be signed by the person responsible for their preparation (California Business and Professions Code) Plans, specifications and calculations shall be signed Toy the California state licensed engineer or architect responsible for_their preparation, for plans deviating from conventional wood frame construction Specify expiration date of license (California Business and Professions; Code)G-s^-f) cn. /t*^-*t Specify'on the Title Sheet of the plans the gross floor area of each element of this project including dwelling, garage, carport, patio, deck and balcony Section 302(c) Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1985 UBC, UMC and UPC and 1987 NEC Submit fully dimensioned plot plan drawn to scale showing location, size, and use of all existing and proposed structures on the lot Identify property lines and show lot dimensions and all easements Show location of all cut or J!iJJLslefi£§_^ Show finish floor elevations and show elevations of 10 11 12 7 14 15' patterns with minimum slopes Section*"30Yfc7 Indicate distance from property lines to proposed building Section 302(c) Show on the title sheet all structures, pools, walls, etc included under, this application Any portion of the project shown on the site plan that is not included with the building permit application filed should be clearly identified as "not included " Clearly show if the lower level is a basement or a story, based on the definitions in Sections 403 and 420 Plot the finish grade (as defined) on the elevations and dimension the distance to the floor above, for story determination if IKK. PROTECTION Exterior walls closer than 3 feet to property lines shall be one-hour rated construction and have no openings Such walls shall have 30 inch parapets when the building floor area exceeds 1,000 square feet on any floor (Table 5-A, Section 1709 (a)) Projections, including eaves, may not extend more than 12 inches into the 3 foot setback from the property line Section 1710 Eaves over required windows shall be not less than 30 inches from the side and rear property lines Section 504 Plastic skylights shall not be installed within 8" of an exterior wall located where openings in such exterior wall are prohibited or required to be protected Section 5207 (a) 7 Projections, including eaves, shall be one- hour fire-resistive construction, heavy timber or of noncombustible material if they project into the 3' setback area from the property line Section 1710 Show location of permanently wired smoke detector, centrally located in corridor or area giving access to sleeping rooms or above stair if sleeping rooms are on upper level Section 1210 A smoke detector shall be installed in the basement of dwelling units having a stairway which opens from the basement into the dwelling Such detector shall be connected to a sounding device or other detector to provide an alarm which will be audible in the sleeping area Section 1210 When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided at existing bedrooms per item 16 above 5/10/89 ROOM SIZES. LIGHT. VEHTILAIIOM AMD GLAZING 2CT Habitable rooms, other than kitchens, shall / contain at least 70 square feet of floor area At least one room shall have not less than 120 square feet of floor area Section 1207 (b) jfl Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1205 (a) Appears to be deficient in Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet In bathrooms, laundry rooms and similar rooms 1/20 of area is required and minimum is 1 5 sq ft (Section 1205 (a)) At least 1/2 of the common wall must be open and have an opening not less than 25 sq ft nor one tenth of the floor area of the interior room if light and ventilation is being supplied from an adjacent room Section 1205 (a) yT Required windows shall not open into a roofed porch unless the ceiling height is at least 7 feet, the longer side is at least 65% open, and the porch abuts a street, yard or court Section 1205 (a) 25 Provide mechanical ventilation capable of providing five air changes per hour in bathrooms, water closet compartments, laundry rooms and similar rooms if required openable windows are not provided Section 1205 (a) 26 No habitable room, other than a. kitchen, shall Vta 1 Af & i~V»a« "7 I fi'l i r» a«xf H ^ mrt«e- i rtr» O*%*t *- •« r%« 27 be less 1207 (c) in any dimension Section Show that ceiling height for habitable rooms is a minimum of 7'6" Section 1207 (a) 28 Show ceiling height for laundry rooms, hallways, corridors, and bathrooms is a minimum of 7'0" Section 1207 (a) 29 Dimension on the plans the 30" clear width for water closet compartments and 24" clearance in front of water closet Section 511 (a) 30 Specify safety glazing for glazing in hazardous locations such as glass doors, glazing adjacent to such doors and glazing adjacent to walking surfaces Section 5406 31 32 35 Glazing, in the same wall plane as a door, must be safety glazing if within 12" of the door and less than 60" -above the walking surface, unless the glazing is leaded or faceted glass Section 5406 (d) 6 Glazing in shower and tub enclosures shall be tempered, laminated or approved plastic (including windows within 5 feet of tub or shower floor) Section 5406 (d) 5 Sleeping rooms shall have a window or exterior door for emergency exit Sill height shall not exceed 44" above the floor The window must have an openable area of at least 5 7 square feet with the minimum openable width 20" and the minimum openable height 24" Section 1204 A mezzanine is an intermediate-/f loor and may not have a floor area exceeding 33 1/3 percent of the total floor area in the room below The mezzanine floor must have a clear height of 7 feet, above and below, and must have the long side open to the room below except for posts and protective walls or railings not exceeding 42" in height Section 1716 The loft you show does not comply as a mezzanine floor and is, by Uniform Building Code definition, a story Section 1716 EXITS. SIAIKHAYS. AND RAUJHGS Floors above the second story shall have not less than 2 exits Occupied roofs may have one exit if such occupied areas are less than 500 square feet and located no higher than immediately above the second story Section 3303 (a) Required exit doorways shall be not less than 36" in width and not less than 6'8" in height, and shall be capable of opening at least 90 degrees Section 3304 (e) Provide 36" high protective railing for porches, balconies, and open sides of stair landings Openings between railing shall be less than 6" Section 1711 Show how guardrail connection details are adequate to support 20 pounds per lineal foot at a right angle to the top rail Table 23-B 5/10/89 ,4'0 Provide stairway and landing details Section 3306 (b) & (c) a Maximum rise is 7" and minimum run is 11" When the stairs serves less than 10 occupants, or serves an unoccupied roof, rise may be 8" maximum and run 9" minimum b Minimum headroom is 6'6" c Minimum width is 36" All handrails per Section 3306 (j), shall satisfy the following a Provide handrail for stairways with 4 or more risers Handrail shall be nosing of treads 30" to 34" above the c The handgrip portion of handrail shall be not less than 1 1/4" nor more than 2" in cross-sectional dimension Every stairway landing shall have a dimension, measured in the direction of travel, at least equal to the stairway width Such dimension need not exceed 36 inches Section 3306 (g), 3304 (i) A door may open inward at the top step of a stairway provided the top step is not more than 7 1/2" lower than the floor level L Sectior^3304 Wyfoor /"\. b^gs^^^is ?\££0(^ Providecletaiprs of winding stairway complying with Section 3306 (d) a Minimum tread is 6 inches at any point and minimum 9 inches at a point 12 inches'from where the treads are narrowest~' b Maximum rise is 8 inches c Minimum width is 36 inches Provide spiral stairway details, per Section 3306 (f) a Minimum run is 7 1/2 inches measured at a point 12 inches from where the treads are the narrowest b Maximum rise is 9 1/2 inches Maximum clear opening between risers is 6 inches c Minimum headroom is 6 feet 6 inches d The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail Spiral stairways may not be used for required exits when the area served is greater than 400 sq ft Section 3306 (f) Provide I C B 0 Research Report and number for metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation In buildings over 2 stories in height, provide 3/4 hour fire-rated assemblies for all openings in the exterior wall below or within 10 feet horizontally of an exterior stairway An exit balcony with 2 separated stairways is exempt Section 3306 (1) Openings in exterior walls below or within 10 feet, measured horizontally, of an exterior stair shall be protected by self-closing fire assemblies having a three-fourths-hour fire protection rating when the stair serves a floor level having openings in two or more floors below it An exit balcony with two separated stairways is exempt Section 3306 (1) Exterior stairways shall not project into the 3 foot setback from the property lines Section 3306 (n) The walls and soffits of the enclosed usable space under interior stairs shall be protected on the enclosed side as^ required for one-hour fire-resistive construction Section 3306 corridors have a Section 3305 (b) Within units, show that minimum width of 36 inches ROOFIH6 Specify roof slope Roof slope is not adequate for roof type specified lable 32-B, Section 3203 (h) Specify roof material and application Chapter 32 Specify I C B 0 or U L approval number for roof materials not covered inUBC,eg, tile, etc Section 107 5/10/89 57 The maximum slope for a fire retardant built- •-' up roof, with rock or gravel surfacing, is 3 inches in 12 inches Section 3203 (e) 2 5B The minimum slope for a fire retardant built- • ' up roof, with cap sheet surfacing, is 1/2 inch in 12 inches Section 3203 (e) 3 59 Specify minimum 1/4 inch per foot roof slope / for drainage or design to support accumulated water Section 3207 (a), Section 2305 (f) and Section 2511 (d) 6 60 Show roof drains and overflows Section 3207 61 Provide skylight details to show compliance / with Sections 3401 and 5207 or provide I C B 0 / approval number 62 Plastic skylights must be separated from each other by at least 4 feet Section 5207 (a) 6 Show attic ventilation Minimum vent area is 1/150 of attic area or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents Show required area and area provided Section 3205 (c) HASOHR? — Provide fireplace construction details or note construction to be per attached fireplace standard drawing Chapter 37 Show anchored veneer support and connections attached to wood in Seismic Zones 3 and 4, comply with Section 3006 (d)l and Section 2515 (a) Show ties and #9 wire in horizontal joints Show height and masonry walls construction 24 details of all Note that cleanout penings shall be provided at the bottom of all cells to be grout filled in accordance with Table 24-G Cleanouts shall be sealed before grouting, after inspection Show floor and roof -connections to masonry walls Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater Cross grain tension or bending in wood ledgers is not permitted Section 2310 & 2312 (j)3A Provide details for damp proofing the foundation walls, below finish grade, where usable space exists on the interior side of the walls Section 1707 (d) 78 80 Show a minimum 2" air space and flashing between planter and building walls Section 2516 (c) 7 GARAGE AND CARPORTS Garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling Table 5-B, Section 503 (d) All elements supporting floor above garage, including walls supporting floor joists, must have one-hour fire-resistive protection on the garage side Section 503 (b) Show 1 3/8" solid core self-closing door for openings between garage and dwelling Section 503 (d) Garages are not permitted to open into a room used for sleeping purposes Section 1104 An occupancy separation is not required between carport and residence, provided the carport is open on two or more sides and has no enclosed uses above Section 503 (a) Exception 3 Show garage framing sections, size of header over garage opening, lateral cross bracing at plate line, method bracing garage front and holddowns if required Chapter 23 NOTE Maximum shear panel ratio is 3 1/2 to 1 for height-to-width Table 25-1 Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold Section 3304 (h) Provide an 18" raised platform for any FAU, water heater, or other device in the garage which may generate a flame or spark UMC Section 508, UPC Section 1310 (a) FOOHDAHON RBQOIRHffimS Per soils report, note on the plan the soils classification, whether or not the soil is expansive and note the allowable bearing value Section 2905 (c) The foundation plan does not comply with the soils report recommendations for this project Please review the report and modify design, notes and details as required to show compliance 5/10/89 82 Provide notes on the foundation plan listing the soils report recommendation for foundations, slab and building pad preparation Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report) The soils report recommendations excavations be reviewed by soils engineer Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that 1 The building pad was prepared in accordance with the soils report, 2 The utility trenches have been properly backfilled and compacted, and 3 The foundation excavations, formings and reinforcements comply with the soils report and approved plan " 8^ Show height of all foundation walls Chapter / 23 ( B5y Show height of retained earth onoall foundati ^— walls Chapter 23 Isir-ltjJWO / T^i L~ 91'' Show foundation sills to be pressure treated, or equal Section 2516 (c) 3 Show foundation bolt size and spacing Section 2907 (f) /^/f <=\JL<4 Cn 1 Specify size, I C B 0 number and manufacturer of power driven pins Show edge and end distances and spacing Section 302 (c) If required, show size, imbedment and location of hold down anchors on foundation plan Section 2312 (f), 302 (c) If hold downs are required, note on plan that hold down anchors must be tied in place prior to foundation inspection Section 305 (e) 1 9^ Show adequate footings under all bearing walls / and shear walls Section 2907 (b) Show on the plans stepped footings for slopes steeper than 1 10 Section 2907 (c) X show minimum 18" clearance from grade to bottom of floor joists and minimum 12" clearance to bottom of girders Section 2516 (c) 2 Show pier size, undisturbed soil spacing and Table 29-A depth into 86/ If cut or fill slopes exist, show distance of foundation to edge of cut or fill slopes and show steepness and heights of cuts and fills Chapter 29 Note on plans that wood shall be 61' above finish grade Section 2907 (a) minimum /^( 88 ) Note on plans that surface water will drain ^—-^ away from building and show drainage pattern and key elevations Section 2905 (f) For buildings adjacent to slopes steeper than 3 1, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus 2 percent Dimension foundation per U B C Table 29A 100 Show minimum underfloor access of 18" x Ik" Section 2516 (c) 101 Show minimum underfloor ventilation equal to 1 / sq ft for each 150 sq ft of underfloor area Openings shall be as close to corners as practicable and shall provide cross ventilation on at least two approximately opposite sides Section 2516 (c) 6 102 Specify that posts embedded in concrete shall / be pressure treated per UBC Std No 25-12 Section 2516 (c) 1 FRAMING 103 Show wall bracing Every exterior wood stud wall and main cross-stud partition shall be braced at each end at least every 25 feet of length with 1x4 diagonal let-in braces or equivalent Section 2517 (g) 3 104 In Floors Supported* 1 2 3 Stemwall Width Footing Depth Thickness 6" 8" 10" 12" 15" 18" 12" 18" 2V 6" 7" 8" 2-story buildings, shear panels at the first story (at least 48 inches in width) shall be located at each end or as near thereto as possible and comprise at least 25 percent of the linear length of the wall, or provide design Section 2517(g)3 'Foundations may support a roof in floors Where only a roof is foundation for one floor addition to the supported, use 5/10/89 105 Note cross bridging or blocking Floor joists i rafters 12" or more in depth shall be supported laterally by bridging at intervals not exceeding 8 feet, unless both edges are held inline Sec 2506 (h), 2517 (d) 6 106 yshow blocking at ends and at supports of floor joists, rafters and trusses at exterior walls Section 2517 (d) 3, 2517 (h) 6 107 yshow double joists Floor joists shall be doubled under bearing partitions running parallel with the joists Section 2517 (d) 5 108 109- Bearing partitions, perpendicular to joists, shall not be offset from supporting girders, beams, walls or partitions, more than the depth of the joist Section 2517 (d) 5 Show rafter ties not more than 4 above the ceiling ceiling joists (h) 4 Rafter ties shall be spaced feet on center and be just joists, where rafters and are not parallel Section 2517 110 Show rafter purlin braces to be not less than/ 45 degrees to the horizontal Section 2517 (h) 5 111 ' Show double top plate with minimim 48" lap splice Section 2517 (g) 2 112 Show nailing will be in compliance with Table 25-Q 113 ] Show or note fire stops at the following locations per Section 2516 (f) a In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10 foot intervals along the length of the wall, b at all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings, c In concealed spaces between stair stringers at the top and bottom of the run and between studs along and inline with the run of stairs if the walls under the stairs are unfinished, and d in openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials 114,/Show stud size and spacing Maximum allowable stud heights Bearing wall 2 x4 and 2x6 max 10', Non-bearing 2x4 max 14', 2 20' lable 25-E-3 Studs suppo ceiling must Table 25-R-3 floors, a roof and or 2 x 6 at 16" o c Note on A I T C Certificate of Compliance for glued laminated wood members shall be given to the building inspector prior to installation Section 306 (f) 'Detail all post-to-beam and post-to-footing connections and reference the detail to the plan Section 2516 (m) shear transfer connections, including roof and floor diaphragms, to shear walls Section 2513 Specify nail size and spacing for all shear walls, floor and roof diaphragms Indicate required blocking Maintain maximum diaphragm dimension ratios [Tables 25 I, J, K and Section 4713 (d)] Show 3" x 4" or 2" x 6" studs in first story of three story building Table 25-R-3 Provide truss details and truss calculations for this project Specify truss -. identification numbers on the plans (122 /Show 1/2" minimum clearance between top plate of interior partitions and bottom chord of trusses (To ensure loading will be as designed) 123 J Provide roof framing plan/^nd floor franjing Sectj.oa.302i {c) 124 ) Provide framing sections through 1L Section 302 (c) .25 Specify all header sizes for opening over 4' wide Section 2517 (g) 5 126 J Provide calculations for main vertical and V ^/ horizontal framing members and post footings Section 302 (b) 5/10/89 I 127 /Provide calculations for lateral loads, shear panels, shear transfer and related Section 302 (b) '''128 )Show on the plans all structural requirements ^__^X developed in the structural calculations Section 302 (c) (See comments below or at end ) 129 Columns and posts located on concrete or / masonry floors or decks exposed to the weather or to water splash or in basements and which support permanent structures shall be supported by concrete piers or metal pedestals projecting above floors unless approved wood of natural resistance to decay or treated wood is used Section 2516 (c) 4 130 Individual concrete or masonry piers shall project at least 8 inches above exposed ground unless the columns or posts which they support are of approved wood of natural resistance to decay or treated wood is used Section 2516 (c) 4 131 Show location of attic access with minimum size 22" x 30" Section 3205 12 Show draft separation for attic areas between units in a duplex Section 2516 (f) ~ Specify plywood thickness, grade and panel identification index Table 25-N When roof pitch is less than 3 12, design ridge as a beam Section 2517 (h) 135"" If foundation cripple wall studs are less than/ 14" high, framing shall be solid blocking Section 2517 (g) 4 166 Cripple wall studs exceeding 4 feet in height shall be 3 inch by 4 inch or 2 inches by 6 inches when supporting 2 stories Section 2517 (g) 4 Show plywood sheathing over exposed eaves, or other weather exposed areas, is "bonded with exterior glue " Plywood used for exterior wall covering shall be the exterior type Section 2516 (i), 2516(g)3 13B Detail truss layout for 30" x 30" attic access, if required for equipment in the attic 13^ Ridges, hips, and valleys shall be at least one / size larger than supported rafters Section 2517 (h) 3 i140 Jin open beam construction, provide strap ties across the beams at the ridge support Section 2501 (b) MECHANICAL (UNIFORM MECHANICAL CODE) All heating, ventilating, and cooling systems and appliances shall comply with the Uniform Mechanical Cod 144 150 152 Show the size, location and type of heating and cooling appliances or"systems all Show source of combustion air to furnace, per Chapter 6, UMC Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70 degrees F at 3 feet above the floor in all habitable rooms Show basis for compliance UBC, Sec 1211 Show minimum 30" deep unobstructed working space in front of furnace Section 505, UMC Note on plans, "clearances to be per manufacturer's listing " Section 504, UMC Furnace shall not be installed in any bedroom, bathroom or in a closet or confined space with access only through such room unless specified as direct vent appliance, enclosed furnace or electric heating appliance Section 704 UMC Show I C B 0 fireplace approval number for prefab Show access to the attic or underfloor furnace to be minimum 30 inches by 30 inches Section 708 & 709 UMC Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 24 inches wide Section 708 UMC Show permanent electrical outlet and lighting fixture controlled by a switch for the attic furnace Section 708 UMC Show details to comply with Section 709 for furnace under the floor, or Section 710 for roof or outside furnace Note on plan Gas vents and non-combustible piping, in walls, passing through three floors or less shall be effectively draft stopped at each floor or ceiling UBC, Section 1706 (a) 6 Provide dryer vent to 1903 outside UMC, Section 5/10/89 ELECTRICAL (NATIONAL ELECTRICAL CODE) All wiring shall comply with the National Electrical Code 15V Show on the plan the amperage of the electrical - service, the location of the service panel and the location of any sub-panels If service is over 200 amps, submit single line diagram, panel schedule and load calculations 155 Show location of all electrical receptacles 15£ Electrical receptacle locations and/or spacing / is not adequate in Show at least one convenience outlet other than outlets for laundry, etc , outdoors, in garages and basements NEC, Art 210-52 166 4 162 / Note convenience outlets in bathrooms, kitchen counter top(s) within 6 feet of the kitchen sink, outdoors, and in (other than for laundry shall be GFI protected garages and basements and similar equipment) NEC, Art 210-8 — Note electrical system ground to be provided per NEC, Art 250-81 PLOHBIHG (UHPDKM PUMBING CODE") bO Show water heater size, type and location on plans UPC, Section 1301 Show source for providing combustion air to fuel burning water heater If wall openings in an enclosure are used, at least one-half of the required opening area shall extend into the upper twelve inches of the enclosure and one- half within the lower twelve inches UPC, Section 1307 Fuel combustion water heater shall not be installed in bath or bedroom or in a closet opening into bath or bedroom UPC, Section 1309 Provide adequate barrier to protect water heater from vehicle damage UPC, Section 1310 Show T and P valve on water heater route of discharge line to exterior UPC, Section 1007 (e) and show Note on the plan that hose bibbs and lawn sprinkler system shall have approved backflow prevention devices UPC, Section 1003(h) & (1) Show shower stall can accommodate a 30" circle and has a minimum floor area of 1,024 sq in UPC 909 (d) MOISE INSULATION (DOPUXES) 167 Show details of duplex common (party) walls / and floor/ceiling assemblies to achieve a Sound Transmission Class (STC) rating in walls of 50 decibels and an Impact Insulation Class (IIC) rating on floor/ceiling of 50 decibels Title 25 168 Show how penetrations of assemblies for piping, electrical devices, recessed cabinets, bathtubs, soffits, or heating ventilating, or exhaust ducts shall be sealed, lined, or insulated to maintain required sound transmission rating Title 25 ; 9 Provide insulation in walls and ceiling to achieve STC of 50 between garage and living area if garage use is not controlled by resident Title 25 ENERGY COHSERVAHOK 'ermit applications received after June 30, 1988, are regulated by the new Residential Energy Standards Provide plans, calculations and worksheets to show compliance ,e new regulations require a properly completed and properly signed Form CF-1R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design 'Section 1403 (a) 1, Title 24, states that Form CF-1R shall be signed by the person responsible for its preparation The signer shall be a civil engineer, mechanical engineer, electrical engineer, architect, general building contractor, mechanical contractor, or electrical contractor licensed or registered to practice by the State of California or other individual eligible under Division 3 of the Business and Professions Code to sign such documents Document signers are subject to the limitations in Division 3 of the Business and Professions Code Please provide the signature 173J All energy items shown on the plans must be in agreement with the information shown on the properly completed Form CF-1R 5/10/89 174 ' Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Energy Conservation Requirements" s175 Show the make, model and efficiency of the ' space heating (or cooling) system and provide heat loss calculations if the output exceeds 45,000 BTU/Hr y6 For room additions, show that the glazing area / of the addition does not exceed 16% of the newly-conditioned floor area, plus glazing removed or relocated due to the addition 177 jProvide fluorescent general lighting in kitchen(s) per CAC, Title 2k, 2-5352(J) 178 Please see additional corrections, or remarks, ' on the following page The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 619/560-1468, to perform the plan chefik for your project If you have-any pla/r^he 5t|Esgil Corporat Thank you 5/10/89 10 Datei Jurisdiction_A.lo-ttd Prepared byt PLAN CHECK NO. VALUATION AND PLAN CHECK FEE ~ / Q Bldg. Dept, p Esgil - .^ ^-H- ' /BUILDING ADDRESS )^>G7 ( ^rTfl*^*. / n APPLICANT/CONTACT ^ PHONE NO. BUILDING OCCUPANCY i?-3 //Y) TYPE OF CONSTRUCTION bM/ BUILDING PORTION v^-p/9 i^~j- •^ t^f^[ ; (^4u34*»j£Jr7^ (nctSur^Ci. i UJert^ ^iw/P I/ Air Conditioning Commercial Residential Res. or Comm. Fire Snrinklers Total Value BUILDING AREA / t-rrjft / <9^4/ £i£~O 5-5- z_ ^o y^1 DESIGNER PHONE CONTRACTOR VALUATION MULTIPLIER dyfj (o9> 17 /7 17 @ § e PHONE VALUE 9j5"T7<y^ 7fl. ^ / 2x //,&£-& ci }<a>(2 r */1 ft. ^&Q liters Building Permit Fee $ Plan Check Fee $ COMMENTS / J & SHEET / OF /12/87 BUILDING PLANCHECK ENGINEERING CHECKLIST DATE PLANCHECK NO s T C H E C K/ N D C H E Cl K/ R D C H E \C \K / PROJECT ID ,*>=£2 LEGAL REQUIREMENTS Site Plan //•** 790 ) ^J 1— 1 1— J 1 Provide a fully dimensioned si \) ; ,\f,^ north arrow, •property lines, -"e^ ITEM COMPLETE ITEM INCOMPLETE - NEEDS YOUR ACTION X ITEM SELECTED a plan drawn to scale Show ^.. ... -_ - _. ... . , nents,•existing and proposed structures,Streets,"existing street improvements,"'right-of- way width and"dimensioned setbacks Show on site plan Finish floor elevations, pad elevations^ jilevations of finish grade adiacent to building, existing topographical lines, existing and proposed slopes, driveway with percent (%) grade and drainage patterns 3 Provide legal description and Assessors Parcel Number Discretionary Approval Compliance (gee. MS 4 No Discretionary approvals were required X 5 Project complies with all Engineering Conditions of Approval ^ for Project No MS79& _ 6 Project does not comply with the following Engineering Conditions of Approval for Project No _ Date/Conditions complied with by Field/Review Field review completed No issues raised 8 Field Review completed The following issues or discrepancies with the site plan were found s\ A Site lacks adequate public improvements B Existing drainage improvements not shown or in conflict with site plan C Site is served by overhead power lines D Grading is required to access site, create pad or provide for ultimate street improvement FRM0010 DH 08/29/89 Site access visibility problems exist Provide onsite turnaround or engineered solution to problem Other Dedication Requirements _9 No dedication required/ \ .10 Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8V' x 11" plat map and submit with a title report and the required processing fee All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit The description of the dedication is as follows Dedication completed, Date By Improvement Requirements 12 No public improvements required SPECIAL NOTE Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City inspector prior to occupancy Public improvements required This project requires construction of public improvements pursuant to Section 18 40 of the City Code Please have a registered Civil Engineer prepare appropriate improvement plans and submit for separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit The required improvements are Improvement plans signed, Date By FRM0010 DH 08/29/89 .13 Improvements are required Construction of the public improvements may be deferred in accordance with Section 18 40 of the City Code Please submit a letter requesting deferral of the required improvements together with a recent title report on the property and the appropriate processing fee so we may prepare the necessary Future Improvement Agreement The Future Improvement Agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit Future Improvement Agreement completed, Date By Gradi nq /tfequi rements Inadequate information available on site plan to make a determination on grading requirements Please provide more detailed proposed and existing elevations and contours Include accurate estimates of the grading quantities (cut. rn 1 , import, export) 14 15 No grading required as determined by the information provided on the site plan Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted for separate plan check and approval through the Engineering Department NOTE The Grading Permit must be issued and grading substantially complete and found acceptable to the City Inspector prior to issuance of Building Permits ByGrading Inspector sign off Date Miscellaneous Permits Right-of-Way Permit not required Right-of-Way Permit required A separate Right-of-Way Permit issued by the Engineering Department is required for the fol 1 owi ng ; Curb gar -ft**" ne of F-LAAf sf SK/^ <yf* 3 20 Sewer Permit is not required Sewer Permit is required A Sewer Permit is required concurrent with Building Permit issuance The fee required is noted below in the fees section. Industrial Waste Permit is not required FRM0010 DH 08/29/89 .21 Industrial Waste Permit is required Applicant must complete Industrial Waste Permit Applicantion Form and submit for City approval prior to issuance of Building Permits Permits must be issued prior to occupancy Industrial Waste Permit accepted - Date- By X Y23-/V23 ^7£& Fees Required .22 Park-in-Lieu Fee Quadrant Nlw Fee per Unit Traffic Impact Fee Fee Per Unit *b£&"~ Total Fee .24 Bridge and Thoroughfare Fee Fee per Unit Total Fee Total OS. X25 _ 26 X-27 28 Public Facilities Fee required Facilities Management Fee Zone Sewer Fees Permit No Fee ^ I Fee EDU's Sewer Lateral required Fee la-fera I ) -JUJ77; AUTHORIZATION TO ISSUE PERMIT FRM0010 DH 08/29/89 Sr- PLANNING CHECKLIST Plan Check No APN PI anner Address Phone 438-1161 (Name) Type of Project and Use Zone &-(Facilities Management Zone Legend Item Complete Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck number that deficiency was identified Environmental Review Required YES DATE OF COMPLETION NO TYPE Compliance with conditions of approval' If not, state conditions which require action Conditions of Approval Discretionary Action Required YES NO X TYPE APPROVAL/RESO NO PROJECT NO DATE OTHER RELATED CASES Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval uran Coastal YES NO V DATE OF APPROVAL Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval Landscape Plan Required YES NO See attached submittal requirements for landscape plans Site Plan [3LH D 1 Provide a fully dimensioned site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimensioned setbacks QII] D 2 Snow on Slte P1an Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and driveway efnn can ana ana nan ana 3 Provide legal description of property 4 Provide assessor's parcel number Zoning 1 Setbacks r Front Required ^ Shown Int Side Street Side Rear 2 Lot coverage 3 Height 4 Parking Guest Required C> Shown Required hf Shown Required i^ Shown Required Shown Required Shown Spaces Required Spaces Required / *5' H' IT,' Shown Shown Additional comments and remarks have been made on the building plans. These marked-up plans may be picked up at the Building Department. These marked- up plans must be resubmitted with the revised plans for this project. Have plans been marked up' YES NO OD D Additional Comments OK TO ISSUE //S^X^^/ /^ I DATE (7 PLNCK FRM Point System Summary Climate Zone 7 P-2R BUILDING DATA Condiponed Floor Area "2_~>3.O c;S lab/Raised Floor Check all applicable Unit Type condition(s) [X] Single Family Detached (SFD) [ ] Addition Alone [ ] Single Family Attached (SFA) [ ] Existing Building [ ] Mulu Family (MF) [ ] Existing Plus Addition 1 Northp^, So(]th Glass Area % Glass 77 3 Skylight 3o Total SCORE CARD 1 Ceiling Insulation 2 Wall Insulation 3 Raised Floor Insulation 4 Slab Edge Insulation 5 Infiltration 6 Glass Heat Loss 7 Shading (Shade Open) North East South West Skylight 8 Shading (Shade Closed) North East South West Skylight Measures P-/9 or R vilue [30] R-KRviluelll] P.-I? R vilue [19] O R vilue [0] Standard Type [double] ^J®% Glass 0 /=> 2. 1 / s 8 'f.j/gy 9 V-4 U vilue [0035] Or c? O'lS L value (0098| or Q. ) •"•" 1 V vilue [0 037] or F2 ficwf [0 77] O <cZ> U vilue |065] SC Point Scores J.'ilL. _0_ o 0 . 8 /*U, =..a /.f.6, = * Totil Clan (20) Eff % Glass /:?. » o /„(, x x .e /.&; =ift /. % Glass ' SC = o -//.) /.i - AJ 7 r* ' Eff % Glass x x x x x |t l*L -9 Interior Thermal Mass 10 Exterior Wall Mass A Eilenor Will Mail Interior Miii/CFA Si 11 Heating System '' x ' ' = Zonal Control7 ( Y /Si) SE « HSPF D"" Efficiency (0 78]C- ' [072/66] 12 Cooling SystemrfldlJ&r—~ x = Zonal ControP(Y(N/ SEER [8 91 13 Water Heating ~Ty?e [SO] Credit [none] Duct Efficiency [0 74] Effective SEER (6,591 Point Total Sum !-« '0.10 California Energy Commission March 1988