Loading...
HomeMy WebLinkAbout1372 CYNTHIA LN; ; CB100708; Permit06-02-2010 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No: CB100708 Building Inspection Request Line (760) 602-2725 1372CYNTHIALNCBAD RESDNTL Sub Type: 1562315600 Lot#: $25,122.00 Construction Type: Reference #: 0 Structure Type: 0 Bathrooms: WATT: 474SF LOFT INFILL RAD 0 NEW Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Orig PC#: Plan Check* ISSUED 04/23/2010 JMA 06/02/2010 06/02/2010 Applicant: MICHAEL ARELLANO 2091 LAS PALMAS DR. #D CARLSBAD 92026 760-438-2963 Owner: WATT DAVID&GINA 1372CYNTHIALN CARLSBAD CA 92008 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee $260.88 $0.00 $169.57 $0.00 $0.00 $2.51 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Add'l Reel. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (31 041 93) License Tax (43041 93) Traffic Impact Fee (31 05541 ) Traffic Impact Fee (4305541 ) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing InLieu Fee Housing Credit Fee Additional Fees TOTAL PLANS STORAGE $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $20.00 $24.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $477.96 Total Fees:$477.96 Total Payments To Date:$477.96 Balance Due:$0.00 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set folh in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717/2718/2719 Fax 760-602-8558 www.carlsbadca.gov Plan Check No. DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires theapplicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars ($500)). Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: \ 11 have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I 11 have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co Policy No. Expiration Date Thjs section need not be completed if the permit is for one hundred dollars ($100) or less. yQ Certificate of Exemption: I certify (hat in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage^ unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provj^e^forj* Sectjpjf tfff of the Labor code, interest and attorney's fees. -£$" CONTRACTOR SIGNATURE.I AGENT DATE D / hereby affirm that I am exempt from Contractor's License Law for the following reason: | | I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractors License Law). | | I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. l~~|Yes I JNo 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with (he following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address /phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): ^PROPERTY OWNER SIGNATURE QAGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? I I Yes I !NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 1 lYes I I No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? I lYes \\Ho IF ANY OF THE ANSWERS ARE YES, / EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and demolitior^cgiiSruction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the raovisions/efBi^Code shall expire by limitation and become null and void if the building or wort^uthorized by such permit is not commenced within 180 days from the date of such permit or if the buikiing orwptk auth/ftedby^riperrnit is suspended or abandoned at any time after the work is commenced foryfi period of 18p days (Section 106.4.4 Uniform Building Code). ^APPLICANT'S SIGNATURE ./^Zjt/%,/^/st-~— DATE H / 7'Z /9 f~> I City of Carlsbad Bldg Inspection Request For. 07/29/2010 Permit* CB100708 Title: WATT: 474SF LOFT INFILL Description: Inspector Assignment: TP 1372 CYNTHIA LN Lot: Type:RESDNTL Sub Type: RAD Job Address: Suite: Location: APPLICANT MICHAEL ARELLANO Owner: WATT DAVID&GINA Remarks: Phone: 619572i800 Inspector: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By: ARNOLD Entered By: CHRISTINE Act Comments if Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# SW100092 ISSUED WATT RESIDENCE; Inspection History Date Description Act Insp Comments 07/28/2010 89 Final Combo NS TP 07/06/2010 17 Interior Lath/Drywall AP TP 07/01/2010 14 Frame/Steel/Bolting/Welding AP TP CORR. 07/01/2010 16 Insulation AP TP City of Carlsbad BUILDING DfPARTMINT 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: 780-602-7541 / Fax: 760402-8B5B Plan Chech Comments / 2OO7 Codes To:From: Steve Fax:Paces:1 Phone:Date: Re:AddrBSt: (?)12_ 'QytviKtoi L .AV CONTACT HOURS FOR STEVE 80ROSSAY: TUESDAY THROUGH FRIDAY: 1PM 5PM «> Please make corrections referred to below and run TWO new prints. If red marks, are on olans as a part of this Plan Check response please return red marked set with the new prints. <«>)Thto tm * BUILDING REVIEW ONLY. Comments or approval do not annfr to any oih«r CMy NUpartment review. For Information on the status of approval from other departments pteasa contact staff Q760-602-2717 / 2718 / 2719. ii 3. o •*~-J City of Carlsbad Public Works Engineering BUILDING PLANCHECK CHECKLIST DATE: BUILDING PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER: ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. D A Right-of-Way permit is required prior to construction of the following improvements: DENIAL the attached report of deficiencies marked Make necessary corrections to plans or itions for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. Date: Date: Date: By: By: By>><X' , FOR OFFICIAL USE ONLY , ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: / 't- t 1 v; A.. \ Date: ^57^ ATTACHMENTS D Dedication Application/Checklist U Encina Wastewater Screening Survey D Encroachment Application/Checklist D Final Map (Reference) D Grading Plan Application/Checklist D Improvement Application/Checklist D Neighborhood Improvement Agreement D RigW-of-Way Permit Submittal Checklist and Information Sheet Oy Storm Water Compliance Forms [] Other ENGINEERING Name: DEPARTMENT CONTACT PERSON Linda Ontiveros City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: (760) 602-2773 Fax: (760) 602-1052 Email: Linda.Ontiveros@carlsbadca.gov CFD INFORMATION Reference No(s): NO, Recordation: Subdivision/Tract:/ 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2720 • FAX (760) 602-8562 BUILDING PLANCHECK CHECKLIST . ST RD SITE PLAN n D 1. Provide a fully dimensioned site plan drawn to scale. Show: A. B. C. D. E. North Arrow Existing & Proposed Structures Existing Street Improvements Property Lines (show all dimensions) Easements _ > ft ( F. Right-of-Way Width & Adjacent Streets G Driveway widths H. Existing or proposed sewer lateral I. Existing or proposed water service J. Existing or proposed irrigation service K. Submit on signed/approved plans DWG No. 2. Show on site plan: A. Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. 3. Include on title sheet: A. Site address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. Show all existing use of SF and new proposed use of SF. Example: Tenant Improvement for 3500 SF of warehouse to 3500 SF of office. EXISTING PERMIT NUMBER DESCRIPTION BUILDING PLANCHECK CHECKLIST ST RD n n 3 D r? DISCRETIONARY APPROVAL COMPLIANCE 4a. Project does not comply with the following Engineering Conditions of approval for Project No. 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 17.000 . pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 Yt" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by:Date: n n IMPROVEMENT REQUIREMENTS 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 82.000 . pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $441 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: BUILDING PLANCHECK CHECKLIST (ST ,RD IMPROVEMENT REQUIREMENTS continued D D D D 6c. Enclosed please find your Neighborhood Improvement Agreement (NIA). return agreement signed and notarized to the Engineering Department. Please Completed by:Date: 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. nnn GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 15.16.010 of the Municipal Code. 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill import, export). This information must be included on the plans. 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by:Date: 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) 7d .No Grading Permit required. 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS RIGHT-OF-WAY PERMIT 8. A Right-of-Way permit is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. To see current requirements, visit our website: www.carlsbadca.gov/development-fornris Right-of-Way permit required for: BUILDING PLANCHECK CHECKLIST ,ND ,RD n n INDUSTRIAL WASTE PERMIT 9. If your facility is located in the City of Carlsbad sewer service area, you must complete the attached Industrial Wastewater Discharge Permit Screening Survey. Fax or mail to Encina Wastewater Authority, 6200 Avenida Encinas, Carlsbad, CA 92011, (760) 438-3941, Fax (760) 476-9852. n n STORM WATER REQUIREMENTS Construction Compliance l~l CD 10a. Project Threat Assessment Form complete. d D 10b. Enclosed Project Threat Assessment Form incorrectly completed. Please make the corrections, re-sign a new form and resubmit with next submittal. I I O 10c. Requires Tier 1 Storm Water Pollution Prevention Plan Please complete attached form and return (SW (Q --^24- I I O 10d. Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP payment of processing fee, and review by City D L"H D D dJ D D D CU Post-Development (SUSMP) Compliance 10e. Storm Water Standards Questionnaire complete. 10f. Stormwater Standards Questionnaire incorrectly completed. Please make the corrections, re-sign the questionnaire and resubmit with next submittal. D 10g. Project is subject to Standard Stormwater Requirements. See City Standard Urban Stormwater Management Plan (SUSMP) for reference. C] 10h. Disconnect Discharges per SUSMP. Do not connect runoff from impervious surfaces to storm drains without first discharging water over landscape areas first. See SUSMP. D 1 0i. Minimize use of impervious surfaces per SUSMP. Redesign to reduce the excessive use of impervious area (pavement) on project. Use a balanced design of pervious surfaces (landscape area, planters, etc.) and impervious surfaces. See SUSMP. D 10j. Trash Storage areas must be designed per City Standards (GS-1 6) to avoid contact with storm runoff. D D D 10k. Project is subject to Priority Development Project Requirements D D D 101. Prepare and submit of a Storm Water Management Plan (SWMP). Requires payment of processing fee and review by City. 10m. Project does not comply with recommendations of the approved SWMP. Redesign to comply and resubmit. BUILDING PLANCHECK CHECKLIST ST 2ND 3RD DEVELOPMENT FEES f~~l C] 11. Q Required fees have been entered Q More information needed Q No fees required WATER METER REVIEW D D D 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. • All single family dwelling units receive "standard" 1" service with 5/8" meter. • All residential units that need to be fire sprinkled receive a 1" meter. See Carlsbad Municipal Code Section 17.04.230 for Automatic fire extinguishing systems criteria. • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. • Maximum service and meter size is a 2" service with a 2" meter. NOTE: Upon declaration of Drought Response Level 3 condition, no new potable water service shall be provided and no new temporary meters or permanent meters shall be provided. See Ordinance 44 for more information. HU l~~l [U 12b. Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: • If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: STA1+00 Install 2" service and 1.5: meter (estimated 100 gpm) BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD WATER METER REVIEW continued d f~l Q 12b. Irrigation Use (continued) Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water service boundary, the City is in the process of switching these irrigation services/meters to a new recycled water line D CH D 12c. Irrigation Use (where recycled water is available) Recycled water meters are sized the same as the irrigation meter above. • If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, the City of Carlsbad cannot guarantee the refund. The applicant must deal with the SDCWA for this. D D D 13. Additional Comments: STORM WATER COMPLIANCE ASSESSMENT B-24 Building Department 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov am applying to the City of Carlsbad for the following type(s) of construction permit: Building Permit Q Right-of-Way Permit Q My project is categorically EXEMPT from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it only requires issuance of one or more of the following permit types: Electrical Fire Additional Fire Alarm Fixed Systems Mechanical Mobile Home Plumbing Patio/Deck Re-Roofing Sign Spa-Factory Sprinkler Water Discharge Project Storm Water Threat Assessment Criteria* No Threat Assessment Criteria LI My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it meets the "no threat" assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier Level. My project does not meet any of the High, Moderate or Low Threat criteria described below. Tierl - Low Threat Assessment Criteria My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project meets one or more of the following criteria: • Results in some soil disturbance; and/or • Includes outdoor construction activities (such as roofing, saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling). Tier 2 - Moderate Threat Assessment Criteria LI My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria: • Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code); or, • Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria: • Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or • Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or • Disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or • Construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). Tier 3 - Significant Threat Assessment Criteria O My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or O My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, refueling and maintenance areas: or, Ll My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s). / certify to the best of my knowledge that the above checked statements are true and correct. I understand and acknowledge that even though this project does not require preparation of a construction SWPP, I must still adhere to, and at all times during construction activities for the permit type(s) check above comply with the storm water best management practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards. 'The City Engineer may authorize minor variances from the Storm Water Threat Assessment Criteria in special circumstances where it can be shown that a lesser or higher Construction SWPPP Tier Level is warranted. Project Address:Assessor Parcel No. Owner/Owner's Authorized Agent Name: Owner/Owner's Auth" City Concurrence: a YES a NO By:Date:/ Project ID: B-24 Page 1 of 1 Rev.03/09 PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB10-0708 Address 1372 Cynthia Lane Planner Chris Sexton Phone (760) 602-4624 APN: 156-231-56 Type of Project & Use: loft infill Net Project Density: 1.0 DU/AC Zoning: R-1 General Plan: RLM Facilities Management Zone: 1 CFD (in/out) #_Date of participation: Remaining net dev acres:_ Circle One (For non-residential development: Type of land used created by this permit: I I Legend: Kl Item Complete Q Item Incomplete - Needs your action D D Environmental Review Required: YES D NO D TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: D D Discretionary Action Required: YES D NO D TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: D n Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES |~l NO [~~1 CA Coastal Commission Authority? YES Q NO Q If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): C] CH Habitat Management Plan Data Entry Completed? YES D NO D If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) n n Inclusionary Housing Fee required: YES Q NO D (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES D NO D (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08 Site/Plan: Kl D D Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. Policy 44 - Neighborhood Architectural Design Guidelines IKI D D 1. Applicability: YES D NO D D D D 2. Project complies: YES D NOQ D D D D n n Zoning: 1.Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: Required 201 Shown 20' Required 6^ Shown 61 Required Shown. Required 121 Shown 12' Required Shown _ 2. Accessory structure setbacks: Front: Interior Side: Street Side: Rear: Structure separation: Required Required Required Required Required Shown Shown Shown Shown Shown 3. Lot Coverage: 4. Height: 5. Parking: Required <40% Shown <40% Required <30' Shown 24'6" Spaces Required 2 Shown 2 (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required _ Shown _ Additional Comments _ OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08 ENGINEERING SUN Structural Engineering, Inc. Consulting Structural Engineers 2091 Las Palmas Dr. Suite D Carlsbad, CA. 92011 Tel/Fax: 760-438-1188 Structural Calculations Watt Remodel Guard Rail Connection Design SUN Structural Engineering ENGINEERING Consulting Structural Engineers uJATT Date: 05/2010 By: C.S. Sheet- ( P T<«r VATT Date: 05/2010 SUN Structural Engineering By: c.S. ENGINEERING Consulting Structural Engineers Sheet- P- leu- r CHBck WATTDate: 05/2010 SUN Structural Engineering By: C.S. ENGINEERING Consulting Structural Engineers Sheet- of ENGINEERING SUN Structural Engineering, Inc. Consulting Structural Engineers 2091 Las Palmas Dr. Suite D Carlsbad, CA. 92011 Tel/Fax: 760-438-1188 Structural Calculations Watt Remodel Guard Rail Connection Design in SUN Structural Engineering ENGINEERING Consulting Structural Engineers Date: 05/2010 By: C.S. Sheet- [ P -fgAft/0?V M5_iAe/tf CG Date: 05/2010 SUN Structural Engineering By. c.s. ENGINEERING Consulting Structural Engineers Sheet- 2- f C .i «-" €^ ~x / SUN Structural Engineering ENGINEERING Consulting Structural Engineers Date: 05/2010 By: C.S. Sheet- 3. Of ML ^ f-S ns c PROPERTIES AND MATERIAL WEIGHTS ABOUT THIS GUIDE The products in this guide are readily available through our nationwide network of distributors and dealers. The applications provided in this guide are intended primarily for use in single-family dwellings. For information on how to use these products in multi-family dwellings, or for more information on any iLevel product, contact your iLevel representative. Some VI® joist series aiay not be available in your region. Design Properties (100% Load Duration) TJI* 110 2TB 23D 210 360 :,,k * Joist Weight flteW Basic Properties Joist Only Efxlfl* Maximum Vertical 2.1 J,500_ 3,000 3,330 J57_ 186 206 _k?2JL1,330 1,330 2.5 2.8 '?•! 3.0 4.0 3,160 3,795 6,180 9,500 267 315 "347 419 636 1,560 1,655 1,655 " 1705 2,050 2.8 3.3 3,740 4,990 392 462 509 1,860 1,945 1,945 3.3 "4.2" 7,335 "11,275 612 926 1,955 2,39(f 3.5" 5440 5-Zi<L" 8,405 4.5 12,925 629 691 J30 1,252 2,190 2,190 2,710 ,es PA" End Reaction (IBS) 3W Intermediate He Web Stiffeners Sfrflesers __ 1,005 1,060 JLj)35_ 2,145 2,410 _ fl.A. N.A. 910 1,005 1,060 1,080 1,265 1,935 2,145 "2,410 "2,460~ 3,000 910 1,005 J.Ojip "1,080" 1,265 1,935 2,145" 2,295 2,505 2,765 2,815 3,475 "2,460 3,000 2,295 2,505 A7J>5 2,815" 3,475 1,005 J,060 1,080 ~1~265" 2,145 2,410 "2,46V 3,000 2,765 L2.8W 3~475 (1) Caution: Do not increase joist moment design properties by a repetitive member use factor. General Notes • Design reaction includes all loads on the joist. Design shear is computed at the inside face of supports and includes all loads on the span(s). Allowable shear may sometimes be increased at interior supports in accordance with ICC ES ESR-1153, and these increases are reflected in span tables. • The following formulas approximate the uniform load deflection of A (inches): For TJI® 110, 210,230, and 360 Joists ._ 22.5 wl" 2.67 wiz El d x 10s For TJI® 560 Joists 22.5 wl4 2.29wL2 El d x 105 w = uniform load in pounds per linear foot L = span in 1eet d = out-to-out depth of the joist in inches El = value from table above Material Weights (Include TJI® weights in dead load calculations— see Design Properties table at left for joist weights) Floor Panels Southern Pine W plywood Vs° plywood W plywood IVs" plywood 1/2" OSB 5/8" OSB V»" OSB W OSB 1.7 2.0 psf 2.5 psf 3.8 psl 1.8 psf 2.2 psf 2.7 psf 3.1 psf IVS" OSB 4.1 psf Based on: Southern pine - 40 pcf for plywood, 44 pcf for OSB Roofing Asphalt shingles 2.5 psf Wood shingles 2.0 psf Clay tile 9.0 to 14.0 psf Slate (W thick) 15.0 psf Roll or Bait Insulation (1" thick): Rock wool 0.2 psf Glass wool 0.1 psf Floor Finishes Hardwood (nominal 1") 4.0 psf Sheet vinyl 0.5 psf Carpet and pad 1.0 psf V*" ceramic or quarry tile 10.0 psf Concrete: Regular (1") 12.0 psf Lightweight (1") S.Oto 10.0 psf Gypsum concrete (3/4") 6.5 psf Ceilings Acoustical fiber tile 1.0 psf V2" gypsum board 2.2 psf 5/«" gypsum board 2.8 psf Plaster d" thick) 8.0 psf Code Evaluations: See ICC ES ESR-1387; updated ESR-1153 pending iLevel Trus Joist" TJI' Joist Specifier's Guide TJ-4000 February 2009 Title Block Line 1 You can changes this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Jit|e_BlgckJJne6 Wood Beam Design Title: Dsgnr: Project Desc.: Project Notes: Job* 6v^ s Pr!nte<^ 15 MAR_2C10JO:33AtJ ENERCALC, INC. 1983-2008, Ver: 6.0.19, N:84432 [yc:#: KW-06006410 ; . ""-' •T>--v-ir-.-:^,:-^^^ Description : FB-1 Material Properties Analysis Method : Allowable Stress Design Load Combination 2006 IBC & ASCE 7-05 Wood Species : iLevel Truss Joist Wood Grade : Parallam PSL 2.0E Beam Bracing : Beam is Fully Braced against lateral-torsion D'O 126)L[032j_ T T V T V + f "v4* -x'*- t^ *% £s ~*sr V"-*-"" ^, «**j V>X ^ "&.„. *U,~ '«" "*W >3P -",-• * L. . ""..*•, J<,.»~ •W****' <Ti«k...**ta^'^W "Sfcfc.. .*.!-.. .» .....5* Fb - Compr Fb - Tension Fc-Prll Fc - Perp Fv Ft buckling D(0203i L{0.52)_ f T ' "'"T^, M-'J- j ^^,-Jtf, 2, 900.0 psi 2, 900.0 psi 2,900.0 psi 750.0 psi 290.0 psi 2, 025.0 psi » ' > 'T- ^*; * ' 4jc ^ifcSs, /C. ^i2KLi*(iiii# >ns per iBC 2006, CBC 2007, 200J £ : Modulus of Elasticity Ebend-xx 2,000.0ksi Eminbend-xx 2,000.0ksi Density 32.210pcf 010.088', L!0 22! T » T "•> NDS fs 1 j 525x11875 L- Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load; 0 = 0.1280, L = 0.320 k/ft, Extent = 0.0 -» 6.0 ft, Tributary Width = 1.0 ft Uniform Load: D = 0.2080, L = 0.520 k/ft, Extent = 6.0 -» 11.0 ft, Tributary Width = 1.0 ft Uniform Load: 0 = 0.0880, L = 0.220 k/ft, Extent = 11.0 -» 16.0ft, Tributary Width = 1,0 ft Maximum Bending Stress Ratio Section used for this span fb : Actual = FB : Allowable Load Combination Location of maximum on span = Span # where maximum occurs = Maximum Deflection Max Downward Live Load Deflection : Max Upward Live Load Deflection : Live Load Deflection Ratio : Max Downward Total Deflection : Max Upward Total Deflection Total Deflection Ratio 0.624 1 5.25x11.875 1,808.61 psi 2,900.00 psi +D+L+H 7.946ft Span # 1 0.400 in 0.000 in 480 0.574 in 0.000 in 334 Maximum Forces & Stresses for Load Combinations Load Combination _ Max Stress Ratios Segment Length Span* M V Overall MAXimum Envelope Length = 16.0 ft 1 0.624 0315 *0 Length = 16.0 ft 1 0.189 0096 -tO+L-* Length = 16.0 ft 1 0.624 0,315 +D+Lr+H Length = 16.0 ft 1 0.189 0.096 +D-K3750LKI.750L+H Length = 16.0 ft 1 0.515 0.260 Maximum Shear Stress Ratio Section used for this span fv: Actual Fv : Allowable Load Combination Location of maximum on span Span # where maximum occurs Desiqn OK 0.315 : 1 5.25x11.875 91.33 psi 290.00 psi +D+L+H 0.000ft Span # 1 Summary of Moment Values Mactual fb-design Fb-allow 18.60 1,808.61 2,900.00 5.63 547.74 2,900.00 18.60 1,808.61 2.SOO.OO 5.63 547.74 2,900.00 15.36 1,493.40 2,900.00 Summary of Shear Values Vactual fv-design Fv-allow 3.80 1.15 3.80 1.15 3.14 S1.33 290.00 27.78 290.00 91.33 290.00 27.78 290.00 75.44 290.00 Title Block Line 1 You can changes this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Jjtle_BlgckLJne6 Wood Beam Desig n to,;* S KW-06086410 Description: FB-1 Overall Maximum Deflections - Unfactored Loads Load Combination Span Max."-" Defl Location in Span D^+ir+T 1 075739 8.054 ~ Maximum Deflections for Load Combinations - Unfactored Loads Load Combination ~DOni7 L Only Lr+L Only D+Lr + L Maximum Vertical Reactions - Unfactored Title: Dsgnr: Project Desc.: Project Notes: Job* 3rmec '5MAPSC10 10J QJERCAUXWC. im-im, Ver 6.0.1&, N:84432 License Owner: SUN STRUCTURAL ENGINEERING INS! Load Combincition Max. V Defl (Toooo" Location in Span 0000 ~ Span 1 1 1 1 Max. Downward Defl 0.1741 0.3998 0.3998 0.5739 Location in Span 8.054 8,054 8.054 8.054 Max. Upward Defl 00000 0.0000 0.0000 0.0000 Location in Span W6o.ooo 0.000 0.000 Load Combination OveraiTiMAXlrnum DOnly LOnly Lr-H. Only Support 1 1.292 2.951 2.951 4.242 Support 2 3T84F" 1.179 2.669 2.669 3.849 , £>'-«»' I \f . _ .. -v $ "• -L™. V*-> I 0 ~ "V\ ,o . L • 2 ^.^.a—> "3L. Title Block Line 1 You can changes this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Wood 0ean» Design life*S: KW-0600641& Description: FB-2 Materia^Properties^ Analysis Method: Allowable Stress Design Load Combination 2006 IBC & ASCE 7-05 Wood Species Wood Grade : Douglas Fir - Larch : No.2 Title: Dsgnr: Project Desc.: Project Notes: Job# 4. Pr.ntec '5 MAR 2010.10J4AM Fife: r\reskteneial\Watt Remodeftvertfcai.ee6 6NERCALC, INC. 1983-2008, V«r 6.Q.I& N:84432 License Owner : SUN STRUCTURAL ENGINEERING INC3 Calculations per !BC 2006, CBC 2007, 2005 NDS Beam Bracing : Beam is Fully Braced against lateral-torsion buckling Fb - Compr Fb - Tension Fc - Prll Fc - Perp Fv Ft 900 psi 900 psi 1350 psi 625 psi 180 psi 575 psi E : Modulus of Elasticity Ebend-xx 1600ksi Eminbend-xx 580 ksi Density 32.21 pcf CJ 0921 UP.054; Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load: 0 = 0.0920, L = 0.0540 k/ft, Tributary Width = 1.0 ft DESIGN SUMMARY Maximum Bending Stress Ratio = 0.668 1 Section used for this span 4x12 fb. Actual = 661.27psi FB: Allowable = 990.00psi Load Combination +D+L+H Location of maximum on span = 7.201 ft Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Live Load Deflection = 0.082 in Max Upward Live Load Deflection = 0.000 in Live Load Deflection Ratio = 2129 Max Downward Total Deflection = 0.234 in Max Upward Total Deflection = 0.000 in Total Deflection Ratio = 742 Maximum Forces & Stresses for Load Combinations Load Combination Seg ment Length Span # Overall MAXimum Envelope Length = 14.50 ft 1 +D Length = 14.50 ft 1 +D+L+H Length = 14.50 ft 1 Length = 14.50 ft 1 Max Stress Ratios "M V 0.668 0.435 0.668 0.435 0.2 0.1 0.2 0.1 +D-K).750Lr-t0.75QL-*! Length = 14.50 ft 1 0.610 0.191 Overall Maximum Deflections • Unfactored Loads Load Combination Span Max."-" Defl Maximum Shear Stress Ratio Section used for this span fv: Actual Fv: Allowable Load Combination Location of maximum on span Span # where maximum occurs Design OK 0,209 : 1 4x12 37.59 psi 180.00 psi +D+L+H 0.000ft Span # 1 _ Summary of Moment Values Mactual fb-design Fb-allow 4.07 661.27 990.00 2.65 430.60 990.00 4.07 661.27 990.00 Summary of Shear Values 2.65 3.71 1 0.2342 Location In Span ~T299~' 430,60 603.60 Load Combination 990.00 990.00 Vactual 0.99 0.64 0.99 0.64 0.90 Max. fv-design Fv-allow 37.59 180.00 24.48 180.00 37.59 180.00 24.48 180.00 34.31 180.00 "+" Defl Location in Span 0.0000 0.000 Title Block Line 1 You can changes this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Wood Beam Design ttJc.#:KW-06006410 Description: FB-2 Maximum Deflections for Load Combinations^JMactored J-pads Max. Downward Defl Title: Dsgnr: Project Desc.: Project Notes: Job* Fife: z:\resIdenciai\Wa8 Remode!\verticai.ec6 ENERCALC, INC. 1983-2008, Ver: 6.0.13, H-.84432 Meense Owner : SUN STRUCTURAL- ENGINEERING; ifi|®5 Load Combination DOniy L Only Lr+L Only Span_ .__. 1 1 1 0.1525 0.0817 0.0817 0.2342 Maximum Vertical Reactions - Unfactored Location in Span ""7.299 7.299 7.299 7.299 Support notation : far !efl is $1 Max. Upward Defl 00000 0.0000 0.0000 Location in Span 0.000~"" 0.000 0.000 0.000 Load Combination Overall MAXimum DOnly LOnly Lr-H. Only D+Lr + L Support 1 T7i22~ 0.731 0.392 0.392 1.122 Support 2 1122" 0.731 0.392 0.392 1.122 Title Block Line 1 You can changes this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Title: Dsgnr: Project Desc.: Project Notes: Job* Wood Beam Design l3e.#:KW-06006410 Description : FB-3, Check Exist. 4x12 Material Properties license Owner: SUN STRUCTURAL ENaiNEERtN&Wfgi CaicuSations per IBC 2006, CBC 2007, 2005 HDS Analysis Method : Allowable Stress Design Load Combination 2006 IBC & ASCE 7-05 Wood Species : Douglas Fir - Larch Wood Grade : No.2 Beam Bracing : Beam is Fully Braced against lateral-torsion 0(1-1 uiL.320, V V V » I ~\,~' -t ' , •<?*< * **< "y m, v'»4, *W«, X,-'^ * "1"*- » -«•>"** ,, -><•'"£ %» ^^'<^i?"%fi-*I •*<* *»> *„.,„<!&. *s- ^-ww« •*. .-^v *?- iV, -2. «r Fb - Compr Fb - Tension Fc - Prll Fc - Perp Fv Ft buckling Y v , ^ s f ' z $ /• " ' 900 psi 900 psi 1350 psi 625 psi 180 psi 575 psi £ : Modulus of Elasticity Ebend- xx Eminbend - xx Density ...x. T. ar... 1600ksi 580 ksi 32.21 pcf ...3T T L Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load: 0 = 0.1160, L = 0.290 k/ft, Extent = 0.0-» 4.50 ft, Tributary Width = 1.0 ft Uniform Load: D = 0.180, L = 0.20 k/ft, Extent = 7.0 -» 9.50 ft, Tributary Width = 1.0 ft Maximum Bending Stress Ratio = Section used for this span fb . Actual FB : Allowable Load Combination Location of maximum on span = Span # where maximum occurs = Maximum Deflection Max Downward Live Load Deflection = Max Upward Live Load Deflection Live Load Deflection Ratio : Max Downward Total Deflection Max Upward Total Deflection Total Deflection Ratio 0.482 1 4x12 477.48 psi 990.00 psi +D+L+H 3.762ft Span # 1 0.046 in 0.000 in 2476 0.071 in 0.000 in 1600 Maximum forces & Stresses for Load Combinations Load Combination Segment Length Overall MAXirnum Envelope Length = 9.50 ft +D Length = 9.50 ft +D+1+H Length = 9.50 ft +D+LNH Length = 9.50 ft +D-t0.750Lr*0.750L+H Length = 9,50 ft Span* 1 1 1 1 1 M 0.482 0.164 0.482 0.164 0.403 v 0.252 0.082 0.252 0.082 0.210 Maximum Shear Stress Ratio Section used for this span fv: Actual Fv: Allowable Load Combination Location of maximum on span Span # where maximum occurs Desian OK 0.252 : 1 4x12 45.37 psi 180.00 psi +D+L+H 0.000ft Span # 1 Summary of Moment Values Mactual fb-design Fb-allow 2.94 477.48 990.00 1.00 152.41 990.00 2.94 477.48 990.00 1.00 162.41 990.00 2.45 398.57 990.00 Vactual SummaryofShear Values Fv-allowfv-design 1.19 45.37 180.00 0.39 14.78 180.00 1.19 45.37 180.00 0.39 14,78 180.00 0.99 37.72 180.00 Title Block Line 1 You can changes this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 - 10 Printed: 15 MAR 2010,10:35AM Lie. # : KW-06006410 License Owner : SUN STRUCTURAL ENGINEERING INC Description: FB-3, Check Exist. 4x12 Overall Maximum Deflections • Unfactored Loads Load Combination Span Max.'-" Defl Location in Span Load Combination Max."+" Defl Location in Span D+Lr + L 1 0.0712 4.591 Maximum Deflections for toad Combinations - Unfactored Loads 0.0000 0.000 Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span DOnly LOnly Lr+i Only D+Lr + L 0.0252 0.0460 0.0460 0.0712 Maximum Vertical Reactions - Unfactored 4.718 4.527 4.527 4.591 Support notation : Far left is #1 0.0000 0.0000 0.0000 0.0000 0.000 0.000 0.000 0.000 Load Combination Support 1 Support 2 Overall MAXimum DOnly LOnly Lr-H.0nly D + Lr + L 1.561 0.499 1.062 1.062 1.561 1.300 0.556 0.743 0.743 1.300 BUILDING ENERGY ANALYSIS REPORT PROJECT: The Watt Remodel 1372 Cynthia Dr. Carlsbad, CA Project Designer: Beery Group Inc., Architecture A.I.A 2091 Las Palmas Dr. Suite D Carlsbad, CA 92011 (760)438-2963 Report Prepared by: Julie A.Gustine CMS / Murphy Mechanical, Inc 140 Vallecitos de Oro San Marcos, CA 92069 (760)591-9172 Job Number: 10-04.1694 Date: 4/8/2010 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with the Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 5.0 by Energy Soft User Number: 1536 RunCode: 2010-04-08709:55:2 ID: 10-04.1694 \ 067O TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1R Certificate of Compliance 3 Form MF-1R Mandatory Measures Summary 8 HVAC System Heating and Cooling Loads Summary 11 'EnergyProS.O by EnergySoft Job Number: 10:10-04.1694 User Number: 1536 Project Name Beta Report - Not for Submittal Project Address 7372 Cynthia Dr. Carlsbad Building Type 0 Single Family D Addition Alone D Multi Family 0 Existing+ Addition/Alteration California Energy Climate Zone CA Climate Zone 07 Total Cond. Floor Area 3,87) Date 4/8/2010 Addition 474 # of Stories 2 PERFORMANCE CERTIFICATE: Residential (Part 1 of 5)CF-1R FIELD INSPECTION ENERGY CHECKLIST D Yes 0 No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. 0 Yes D No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ff) Features (see Part 2 of 5)Status Slab Unheated Slab-on-Grade None 1,760 Existing Wall Wood Framed R-13 3,163 Existing Wall Wood Framed R-13 1,395 New Roof Wood Framed Attic R-19 1,700 Existing FENESTRATION U- Exterior Orientation Area(fr) Factor SHGC Overhang Sidefins Shades Status Front (N)261.0 1.190 0.83 none none Bug Screen Existing Left (E)88.0 1.190 0.83 none none Bug Screen Existing Rear (S)116.0 1.190 0.83 none Bug Screen Existing Right (W)112.0 1.190 0.83 none Bug Screen Ex/sting Front (N)35.0 0.550 0.67 none none Bug Screen New Left (E)30.0 0.550 0.67 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status Central Furnace 78% AFUE No Cooling 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status Existing Unit Ducted Ducted Attic, Ceiling Ins, vented 4.2 Altered WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.0 by EnergySoft User Number: 1536 RunCode: 2010-04-08709:55:2 ID: 10-04.1694 Page 3 of 11 Project Name Beta Report -Not for Submittal Building Type 0 Single Family D Multi Family D Addition Alone 0 Existing+ Addition/Alteration Date 4/8/2010 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1R SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System Existing FAU does not include a coo/ing system, field verification is not necessary. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. Energy Pro 5.0 by Energy Soft User Number: 1536 RunCode: 2010-04-08709:55:2 ID: 10-04.1694 Page 4 of 11 PERFORMANCE CERTIFICATE: Project Name Beta Report - Not for Submittal ANNUAL ENERGY USE SUMMARY Residential (Part 3 of 5) Building Type 0 Single Family D Addition Alone D Multi Family 0 Existing+ Addition/Alteration CF-1R Date 4/8/2010 Standard Proposed Margin TDV (kBtu/ff-yr) Space Heating 1+12 14.25 Space Cooling 10.82 70.42 Fans 392 3.82 Domestic Hot Water 13.01 13.01 Pumps °-°o o.oo Totals 47.88 47.50 Percent Better Than Standard: BUILDING COMPLIES - -0.74 0.47 0.77 0.00 0.00 0.38 0.9% NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N)Odeg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1-OQ (N) 7,900 296 Fuel Available at Site: Natural Gas (E) 1,260 778 Raised Floor Area: o fsj 7,720 776 Slab on Grade Area: L7eo W 92° 112 Average Ceiling Height: 10.0 Roof 1-70° ° Fenestration Average U-Factor: 1-13 TOTAL: 642 Average SHGC: 0.81 Fenestration/CFA Ratio: 76.8 % REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMS / Murphy Mechanical, Inc Mj f n A 1 V\\ /1 1 H \fJ*1 i/t /} 4/8/2010Address 140VallecitosdeOro Name Julie A.Gustine (\j /NX WLoTt'^O' City/State/Zip San Marcos, CA 92069 phone (760)591-9172 The individual with overall design responsibility hereby certifies that the proposed b of construction documents is consistent with the other compliance forms and works with any other calculations submitted with this permit application, and recognizes th duct sealing, verification of refrigerant charge, insulation installation quality, and bui installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) f Company Beery Group Inc., Architecture A.I. A I Address 2091 Las Pa/mas Dr. Suite D Name John Beery VJf City/State/Zip Carlsbad, CA 92011 Phone (760)438-2963 f\^ Signed Date uilding design represented in this set heets, with the specifications, and at compliance using duct design, Iding envelope sealing require JK** <!,L wnedV License #Date EnerqyPro 5.0 by EnerqySoft User Number: 1536 RunCode: 2010-04-08709:55:2 ID: 10-04.1694 Paqe 5 of 11 CERTIFICATE OF Project Name Beta Report - COMPLIANCE: Residential (Part 4 of 5)CF-1R Building Type 0 Single Family D Addition Alone Da Not for Submittal n Multi Family 0 Existing+ Addition/Alteration ^/ OPAQUE SURFACE Surface Type Slab Wall Wall Wall Wall Wall Wall Wall Roof Area 1,761 68< 83, 83< 801. 91!. 311 17C 1JOC Li- e 8/2010 DETAILS Factor 3 0.730 ) 0.702 ? 0. 702 t 0.102 J 0.702 > 0. 102 3 0.702 3 0. 702 > 0.049 Insulation Cavity None R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-19 Exterior Frame Interior Frame Azm 0 0 90 780 270 0 90 780 0 Tilt Status 780 Existing 90 Existing 90 Existing 90 Existing 90 Existing 90 New 90 New 90 New 0 Existing Joint Appendix 4 4.4.7-A1 4.3.1-A3 4.3.1 -A3 4.3.1-A3 4.3.1 -A3 4.3.1-A3 4.3.7-43 4.3.1 -A3 4.2.1 -A4 Location/Comments Existing Residence Existing Residence Existing Residence Existing Residence Existing Residence Addition Addition Addition Addition FENESTRATION SURFACE DETAILS ID 7 2 3 4 5 6 7 8 Type Window Window Window Window Window Window Window Window Area 247.0 14.0 61.0 27.0 116.0 112.0 35.0 30.0 U-Factor1 1.190 1.190 1.190 1.190 1.190 1.190 0.550 0.550 (1) U-Factor Type: (2) SHGC Type: EXTERIOR SHADING ID 1 2 3 4 5 6 7 8 Default Default Default Default Default Default Default Default SHGC^ 0.83 0.83 0.83 0.83 0.83 0.83 0.67 0.67 Default Default Default Default Default Default Default Default Azm 0 0 90 90 180 270 0 90 Status Existing Existing Existing Existing Existing Existing New New 1 16-A = Default Table from Standards, NFRC = Labeled 1 16-B = Default Table from Standards, NFRC = Labeled Glazing Type Location/Comments Single Metal Clear Existing Residence Single Metal Clear Existing Residence Single Metal Clear Existing Residence Single Metal Clear Existing Residence Single Metal Clear Existing Residence Single Metal Clear Existing Residence Double Non Metal Clear Addition Double Non Metal Clear Addition Value Value DETAILS Exterior Shade Type Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen 3ug Screen Bug Screen SHGC 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 Window Overhang Hgt Wd Len Hgt LExt RExt Left Fin Dist Len Hgt Right Fin Dist Energy Pro 5.0 by Energy Soft User Number: 1536 RunCode: 2010-04-08709:55:2 ID: 10-04.1694 Len Hgt Page 6 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Build ng Type El Single Family D Addition Alone Beta Report - Not for Submittal d Multi Family El Existing+ Addition/Alteration Date 4/8/2010 BUILDING ZONE INFORMATION System Name Existing Unit Floor Area (ft^) Zone Name New Existing Existing Residence 3,337 Addition 474 Totals Altered Removed Volume 33,370 4,740 Year Built 7973 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Existing Unit 1 Central Furnace 78% AFUE No Cooling 13.0 SEER Setback Status Existing HVAC DISTRIBUTION System Name Heating Cooling Duct Location Existing Unit Ducted Ducted Attic, Ceiling Ins, vented Duct Ducts R-Value Tested? 4.2 D D Dn n Status Altered WATER HEATING SYSTEMS System Name Qty. Existing DHW 2 Rated Input Type Distribution (Btuh) Small Gas Kitchen Pipe Ins 75, 000 Ext. Tank Energy Standby Tank Cap. Factor Loss or Insul. R- (gal) or RE Pilot Value 75,000 0.58 n/a n/a Status Existing MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Hot Water Piping Length £ (ft) § =1 'CM "J=1 i;-5 it £ ? w Pipe Pipe Control Qty. HP ^ °- Plenum Outside Buried **• ~ System Name Length Diameter D D D D D D D D D D Insul. Thick. EnergyPro 5.0 by EnergySoft User Number: 1536 RunCode: 2010-04-08709:55:2 ID: 10-04. 1694 Page 7 of 11 Project Name The Watt Remodel Date 4/8/2010 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3) MF-1R NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1R-ADD, or CF- 1R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: §116(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of §10-111 (a). §117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. §118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. *§150(a): Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§150(c): Minimum R-13 insulation in wood-frame wall or equivalent U-factor. *§150(d): Minimum R-13 insulation in raised wood-frame floor or equivalent U-factor. §150(f): Air retarding wrap is tested, labeled, and installed according to ASTM £1677-95(2000) when specified on the CF-1 R Form. §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150(e)1 A: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1B: Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight-fitting damper and or a combustion-air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §150(j)4: Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. Registration Number: Registration Date/Time: HERS Provider: Energy Pro 5.0 by Energy Son User Number: 1536 RunCode: 2010-04-08T09:55:23 ID: 10-04.1694 Page 8 of 11 Project Name The Watt Remodel Date 4/8/2010 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3) MF-1R §150(m)1: All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150(m)7: Exhaust fan systems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150(m)10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. §114(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §150(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p). Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined as specified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw-base socket. §150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). §150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 teor 100 watts for dwelling units larger than 2,500 ftemay be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi-scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual-on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. Registration Number: Registration Date/Time: HERS Provider: EnergyPro 5.0 by Energy Soft User Number: 1536 RunCode: 2010-04-08T09:55:23 ID: 10-04.1694 Page 9 of 11 Project Name The Watt Remodel Date 4/8/2010 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3) MF-1R §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual- on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150(k)11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (1C) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s) certified to comply with the applicable requirements of §119. Registration Number: Registration Date/Time: HERS Provider: Energy Pro 5.0 by Energy Soft User Number: 1536 RunCode: 2010-04-08T09:55:23 ID: 10-04.1694 Page 10 of 11 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name The Watt Remodel System Name Existing Unit ENGINEERING CHECKS Number of Systems 1 Heating System Output per System Total Output (Btuh) Output (Btuh/sqft) 60,000 60,000 15.7 Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sqft) Total Output (sqtt/Ton) Air System CFM per System Airflow (cfm) Airflow (cfm/sqft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sqft) 0 0 0.0 0.0 0.0 1,600 1,600 0.42 0.0 0.0 % 0.00 Note: values above given at ARI conditions SYSTEM LOAD COIL COOLING PE; CFM Sensible L Total Room Loads 2,497 45,121 Return Vented Lighting 0 Return Air Ducts 2,039 Return Fan 0 Ventilation 0 0 Supply Fan 1,869 Supply Air Ducts 2,039 TOTAL SYSTEM LOAD 51 ,068 Date 4/8/2010 Floor Area 3,811 kK COIL HTG. PEAK atent CFM Sensible 2,740 853 63,610 3,734 0 00 0 -1 ,869 3,734 2,740 69,209 HVAC EQUIPMENT SELECTION Existing FAU 0 Total Adjusted System Output 0 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK A 0 60,000 0 60,000 jg 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) — ^- ^- Outside Air -4 Ocfm i k-fc-f (?) r' ^ I I l_'LJ ^ 'u u Heating Coil Supply Fan 1,600 cfm 4 n n «4 U . . U 1 ROOM 1 COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) Outside Air ^ 0 cfm A r i * (<*? *n ri-<o/ >[] y „ ,. „ ., Supply FanCooling Coil 1,600 cfm 49.2 % ^ LI U ' EnergyPro 5.0 by EnergySoft User Number: 1536 RunCode: 2010-04-08T09:55:23 ID: 10-04. 1694 1 ROOM Page 11 of 11 *r>OLR\ ^% VN -F -s. ^ ^ ^o- ^ \ii Cv\ 51 ^ ^^i fc (^ ^7) | ONr^ S ri T> I J: fe ImpAO \ ^ O