HomeMy WebLinkAbout1376 CYNTHIA LN; ; CB030336; Permit-2003'
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit Permit No: CB030336
Building Inspection Request Line (760) 602-2725
1376 CYNTHIA LNCBAD
RESDNTL Sub Type:
1562309500 Lot#:
$32,334.00 Construction Type:
Reference #:
0 Structure Type:
0 Bathrooms:
WARD RES/ 317 SF LOFT INFILL
OVER LIVING ROOM
RAD
0
NEW
Applicant:
SUSAN & STEPHEN WARD
1376CYNTHIALN
CARLSBAD CA 92008
720-1800
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Orig PC#:
Plan Check#:
ISSUED
01/31/2003
CB
03/28/2003
03/28/2003
Owner:
WARD STEPHEN M&SUSAN L
1376 CYNTHIA LN
OCEANSIDECA 92056
1409 03/28/03 0002 01 02
CGR 282-90
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'l Pot. Water Con. Fee
Reel. Water Con. Fee
$259.67 Meter Size
$0.00 Add*! Reel. Water Con. Fee
$168.79 Meter Fee
$0.00 SDCWA Fee
$0.00 CFD Payoff Fee
$3.23 PFF
$0.00 PFF (CFD Fund)
$0.00 License Tax
$0.00 License Tax (CFD Fund)
$0.00 Traffic Impact Fee
$0.00 Traffic Impact (CFD Fund)
$0.00 Sidewalk Fee
$0.00 PLUMBING TOTAL
$0.00 ELECTRICAL TOTAL
$0.00 MECHANICAL TOTAL
$0.00 Housing Impact Fee
$0.00 Housing InLieu Fee
Housing Credit Fee
$0.00 Master Drainage Fee
$0.00 Sewer Fee
Additional Fees
TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$20.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$451.69
Total Fees: $451.69 Total Payments To Date:$168.79 Balance Due:$282.90
Inspector:
FINAL APPR
SlLDate:Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition* of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3,32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which vou have oreviouslvJjeen aiven a.MQTICE_sirnilarto this^iias towhicrtlhe statute_oKimMions_has previously otherwise expired.
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ONLY
PLAN CHECK NCV_
EST. VAL.
Plan Ck. Deposit
Validated By.
Date
Address (include Bldg/Sifite #)Business Name (at this address)
7104 01/31/03 QQQ2 01 32
Legal Description Lot No.Subdivision Name/Number Unit No. Phase NOT"3 Total 9 of urrtt*
Assessor's Parcel # •Existing Use Proposed Use
Name Address City State/Zip Telephone Fax*
Name Address City State/Zip Telephone #
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]).
Name
State License ft
Address
License Class
City State/Zip
City Business License #
Telephone #
Designer Name
State License #
Address City State/Zip Telephone
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
n I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are:
Insurance Company Policy No. Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS IS 100] OR LESS)
D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties end civil fines up to one hundred
thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code, interest and attorney's fees.
SIGNATURE DATE
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
n I am exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. JJ YES QNO
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number): ^_^
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work):
-^PROPERTY OWNER SIGNATURE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES D NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is commenead tor a period of 180 days^Sactionil06.4.4 Untform Building Code).
WHITE: File YELLOW: Applicant PINK: Finance
PPLICANT'S SIGNATURE
City of Carlsbad Bldg Inspection Request
For: 05/14/2003
Permit# CB030336
Title: WARD RES/317 SF LOFT INFILL
Description: OVER LIVING ROOM
1376 CYNTHIA LN
Lot
Type:RESDNTL Sub Type: RAD
Job Address:
Suite:
Location:
APPLICANT SUSAN & STEPHEN WARD
Owner: WARD STEPHEN M&SUSAN L
Remarks:
Inspector Assignment: JM
Phone: 7603905952
Inspector:
Total Time:
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By: TOM
Entered By: ROBIN
I Comment
Associated PCRs/CVs
Inspection History
Date Description Act Insp Comments
04/08/2003 17 Interior Lath/Drywall
04/03/2003 14 Frame/Steel/Bolting/Welding
04/03/2003 18 Exterior Lath/Drywall
04/03/2003 34 Rough Electric
AP JM
AP JM OK TO DRYWALL
AP JM
AP JM
EsGil Corporation
In Partners/tip -witfi government for Quitting Safety
DATE: March 26, 2003 Q APPLICANT
Q JURIS.
JURISDICTION: Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO.: O3-0336 SET: II
PROJECT ADDRESS: 1376 Cynthia Lane
PROJECT NAME: Ward Addition
• The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
REMARKS: Perforated plans being carried by applicant to City.
By: Bryan Zuppiger Enclosures:
Esgil Corporation
D GA D MB D EJ D PC LOG tmsmtl.dot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576
EsGil Corporation
In ipartnership witR government for Quitting Safety
DATE: February 11, 2003
JURISDICTION: Carlsbad QPOTTREVIEWER
Q FILE
PLAN CHECK NO.: 03-0336 SET: I
PROJECT ADDRESS: 1376 Cynthia Lane
PROJECT NAME: Ward Addition
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Susan & Stephen Ward
1376 Cynthia Lane Carlsbad CA 92008
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Susan & Stephen Ward Telephone #: 760720 7800
-x I -rt tiTTe^fW)""Date contacted: ^ f, I (by: T>) „.,., Fax #:L1- *• ' ^\ pi^c -
Mail - Telephone ^ Fax In Person
REMARKS:
By: Bryan Zuppiger Enclosures:
Esgil Corporation
D GA D MB D EJ D PC 2/3/03 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 *• San Diego, California 92123 * (858)560-1468 *• Fax (858) 560-1576
Carlsbad 03-0336
February 11, 2OO3
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 03-0336 JURISDICTION: Carlsbad
PROJECT ADDRESS: 1376 Cynthia Lane
FLOOR AREA: 317' STORIES: 2
HEIGHT: unknown, no elevations.
REMARKS:
DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY
JURISDICTION: ESGIL CORPORATION: 2/3/03
DATE INITIAL PLAN REVIEW PLAN REVIEWER: Bryan Zuppiger
COMPLETED: February 11, 2003
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments. Clearance from those departments may be required prior to
the issuance of a building permit.
Present California law mandates that residential construction comply with the 2001 edition of
the California Building Code (Title 24), which adopts the following model codes: 1997 UBC,
2000 UPC, 2000 UMC and 1999 NEC (all effective 11/1/02).
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list for a copy) where each
correction item has been addressed, i.e.. plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad 03-0336
February 11, 2O03
• PLANS
1. Please make all corrections on the original tracings and submit two new
complete sets of prints to Esgil Corporation, 9320 Chesapeake Drive, Suite 208,
San Diego, California 92123, (858) 560-1468.
2. The person responsible for their preparation must sign all final sheets of plans.
(California Business and Professions Code).
3. Provide a statement on the Title Sheet of the plans stating that this project shall
comply with the 2001 edition of the California Building Code (Title 24), which
adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC.
• FIRE PROTECTION
4. Show locations of permanently wired smoke detectors with battery backup in the
new and existing construction, except that smoke detectors added at existing
construction need only be battery powered. Section 310.9.1.2:
a) Inside each bedroom.
b) Centrally located in corridor or area giving access to sleeping rooms.
c) On each story.
d) When sleeping rooms are upstairs, at the upper level in close proximity to
the stair.
e) In rooms adjacent to hallways serving bedrooms, when such rooms have
a ceiling height 24 inches or more above the ceiling height in the hallway.
NOTE: Detectors shall sound an alarm audible in all sleeping areas of the unit.
Section 310.9.1.
• GENERAL RESIDENTIAL REQUIREMENTS
5. Show that ceiling height for habitable rooms is a minimum of 7'-6". Section
310,6.1.
• FRAMING
6. Provide framing sections through the loft enclosure. Section 106.3.3.
• ENERGY CONSERVATION
7. Provide plans, calculations and worksheets to show compliance with current
energy standards.
8. Specify on the building plans all of the mandatory energy conservation
requirements as listed on the enclosure titled, "Mandatory Measures Checklist".
9. All sheets of the latest CF-1R form must be imprinted onto the plans (sheets 1 of
3, 2 of 3 and 3 of 3 must be included).
Carlsbad O3-0336
February 11, 2003
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Bryan Zuppiger at
Esgil Corporation. Thank you.
Carlsbad O3-O336
February 11, 2003
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: O3-O336>
PREPARED BY: Bryan Zuppiger DATE: February 11, 2003
BUILDING ADDRESS: 1376 Cynthia Lane
BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VN
BUILDING
PORTION
dwelling addition
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
( Sq. Ft.)
317
cb
Valuation
Multiplier
City Estimate
By Ordinance
Reg.
Mod.
VALUE ($)
32,334
32,334
$259.67
Plan Check Fee by Ordinance
Type of Review:
CD Repetitive FeeRepeats
Complete Review
D Other
. Hourly
Structural Only
Hour
Esgll Plan Review Fee
$168.79
$145.42
Comments:
Sheet of
macvalue.doc
MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page i of 2) MF-1R
Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.
Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of
Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as
minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents
or on this checklist only.
Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable.
DESCRIPTION
Building Envelope Measures:
* §150(a): MinimumR-t9ceilinginsulation.
§150(b): Loose fill insulation manufacturer's labeled R-Value.
* § 1 50(c): Minimum R- 13 wall insulation in wood framed walls or equivalent U-Factor in metal frame walls
(does not apply to exterior mass walls').
• §150(d): Minimum R- 13 raised floor insulation in framed floors.
§ 1 50(1) '• Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no
ercatcr than 2.0 perm/inch.
§ 1 IS: Insulation specified or installed meets insulation quality standards. Indicate type and form.
§116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfilcration Controls
1 . Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fcncstration products (except field-fabricated) have label with certified U-Factor, certified Solar Heat
Gain Coefficient (SHGC). and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§l50(g): Vapor barriers mandatory in Climate Zones Hand 16 only.
§150(0: Special infiltration barrier installed to comply with § 151 meets Commission quality standards.
§ 1 50(c); Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1 . Masonry and factory-built fireplaces have:
a. Closcablc metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilot lights allowed.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 1 1 0-§ 1 1 3: HVAC equipment, water heaters, showerhcads and faucets certified by the Commission.
§ 1 50(h): Heating and/or cooling loads calculated in accordance with ASHRAE. SMACNA or ACCA.
§ 1 5Q(i): Setback thermostat on all applicable heating and/or cooling systems.
§1500): Pipe and tank insulation
1. Storage gas water heaters rated with an Energy Factor less than OJS must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non-recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12
external insulation or R-16 combined mtcm*Uextcrnal insulation.
A. All buried or exposed piping Insulated in recirculaiing sections of hot water systems.
5. Cooling system piping below 55* F insulated.
6. Piping insulated between healing source and indirect hot water tank.
DESIGNER ENFORCEMENT
-
"
Compliance Forms August 2001 A-5
MANDATORY MEASURES CHECKLIST: RESIDENTIAL (page2of2) MF-1R
Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.
Items marked with an asterisk (*) may be superseded by mort stringent compliance requirements listed on the Certificate of
Compliance. When this checklist is incorporated into the permit documents, the features noted shall b« considered by all parties as
minimum component performance specifications for th« mandatory measures whether they are shown elsewhere in the documents
or on this checklist only.
Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable.
DESCRIPTION DESIGNER ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§!50(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated a rneet the requircmec: of the 1998 CMC Sections 601,
603.604, and Standard 6-3; ducts insulated to a minimum installed level cf R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with masis, ope. aerosol sc&ct, or other duct-closure system
that meets the applicable requirements of UL181, UL 181 A, or ULIS1B. If mastic or tape is used to seal
openings greater than 1/4 inch, the combination of masse and either mesh or ope shall be used Building
cavities shall not be used for conveying conditioned rr. Joints and seams of duct systems bid their
components shall not be scaled with cloth back rubber adhesive <iucc upes unless such tape is used in
combination with mastic and drawbands.
2. Building cavities, support platforms for air handlers. Lid plenums dcf.std or constructed with materials
other than sealed sheet metal, duct board or flexible duct shall not be L«d for conveying conditioned
air. Building cavities and support platforms may certain ducts. Duct* csalled in cavities and support
platforms shall not be compressed to cause reductions in the cross-scccctial area of the ducts.
3. Joints and seams of duct systctrj and their compor.;r.a shall not be seisd with cloth back rubber
adhesive duct tapes unless such tape is used in combination with mis;:: and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilating systems serving conditioned spacs have either a^:c.TJtic or readily accessible,
manually operated dampers.
6. protection of Insulation. Insulation shall be protectd from damage, including that due to sunlight,
moisture, equipment maintenance, and wind but re: limited to the following; Insulation exposed to
weather shall be suitable for outdoor service e.g., protected by alumir.uo. sheet metal, painted canvas,
or plastic cover. Cellular foam insulation shall be protected as above cr painted with a coating that is
water retardant and provides shielding from solarntiiation that can eras degradation of the material.
§1)4: Pool and Spa Heating Systems and Equipment.
1. System is certified with 78% thermal efficiency, oa-off switch, weatherproof operating instructions, no
electric resistance heating and no pilot light.
2. System is installed with:
a. At lease 36" of pipe between filter and heater for future solar h»^:z.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
§ 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light (Exception: Non-electrical cookinz acoliances with pilot < 150 Btu/hrj
§ 118 (f): Cool Roof material meet specified criteria
Lighting Measures:
S150(101.: Luminaires for general lighting hi kitchens shall have lamps with an efficacy of 40 lumens/watt
or greater for general lighting rn kitchens. This general lighting shall be controlled by • switch on a readily
accessible lighting CTntrol panejat aiLtntrance to the kitchen.
§ 150(k)2.: Rooms with a shower or bathtub must have either at least one luminaire with tamps with an
efficacy of 40 lumens/watt or greater switched at the entrance to die room or one of the alternatives to this
requirement allowed in § 1 S0(k)2.; and incandescent recessed ceiling futons are 1C (insulation cover)
approved^ .
Compliance Forms August 2001 A-6
BUILDING PLANCHECK CHECKLIST
DATE:
BUILDINGi
PROJECT DESCRIPTION:
ASSESSOR'S PARCEL NUMBER:
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submtttal; therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build.
A Right-of-Way permit is required prior to
construction of the following improvements:
DENIAL
Please see the attached report of deficiencies
marked with D. Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards. Submit corrected plans and/or
specifications to this office for review.
By:
By:
By:
Date:
Date:
Date:
FOR OFFICIALESE ONLY
ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT:
Date:
ENGINEERING DEPT. CONTACT PERSON
Name: JOANNE JUCHNIEWICZ
City of Carlsbad
Address: 1635 Faraday Avenue, Carlsbad, CA 92008
Phone: (760) 602-2775
Application
Dedication Checklist
Improvement Application
Improvement Checklist
Future Improvement Agreement
Grading Permit Application
Grading Submtttal Checklist
Right-of-Way Permit Application
Right-of-Way Permit Submittal Checklist
and Information Sheet
Sewer Fee Information Sheet
CFD INFORMATION
Parcel Map No:
Lots:
Recordation:
Carlsbad Tract:
A-4
H:\VwmDOCSVCHKLSTOuWng Ftendwck CWtt form (Generic)-doc
BUILDING PLANCHECK CHECKLIST
SITE PLAN
3RD
n
n n
1. Provide a fully dimensioned site plan drawn to scale. Show:
A. North Arrow
B. Existing & Proposed Structures
C. Existing Street Improvements
D. Property Lines
E. Easements
F. Right-of-Way Width & Adjacent Streets
G. Driveway widths
H. Existing or proposed sewer lateral
I. Existing or proposed water service
J. Existing or proposed irrigation service
D D 2- Show on site plan:
A. Drainage Patterns
1. Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course.
2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building."
B. Existing & Proposed Slopes and Topography
C. Size, type, location, alignment of existing or proposed sewer and water service
(s) that serves the project. Each unit requires a separate service, however,
second dwelling units and apartment complexes are an exception.
D. Sewer and water laterals should not be located within proposed driveways, per
standards.
3. Include on title sheet:
A. Site address
B. Assessor's Parcel Number
C. Legal Description
For commercial/industrial buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
HMVORCnQOCSCHKLSTOuftllng PtanchM* Odd Form (Ganw13.doc Rev. 7/14/00
BUILDING PLANCHECK CHECKLIST
ird DISCRETIONARY APPROVAL COMPLIANCE
D 4a. Project does not comply with the following Engineering Conditions of approval for
Project No.
D D D 4b- All conditions are in compliance. Date:
DEDICATION REQUIREMENTS
D D 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $15.000. pursuant to Carlsbad
Municipal Code Section 18.40.030.
Dedication required as follows: ,
Dedication required. Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 Y* x 11" plat map
and submit with a title report. All easement documents must be approved and
signed by owner(s) prior to issuance of Building Permit. Attached please find an
application form and submittal checklist for the dedication process. Submit the
completed application fprm with the required checklist items and fees to the
Engineering Department in person. Applications will not be accept by mail or fax.
Dedication completed by:Date:
a a a
IMPROVEMENT REQUIREMENTS
6a. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $75.000. pursuant to Carlsbad Municipal Code Section
18.40.040.
Public improvements required as follows:
Attached please find an application form and submittal checklist for the public
improvement requirements. A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process. The completed application form and the requirements on the
mWORCWOCSVCHKLSTOuMIng PtflrWwck CUM Foon {RIDDLE • HARVEY 7-12-00).*x
BUILDING PLANCHECK CHECKLIST
ST ,RD
ODD
checklist must be submitted in person. Applications by mail or fax are not
accepted. Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit.
Improvement Plans signed by:Date:
6b. Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or
current grant deed on the property and processing fee of $310 so we may
prepare the necessary Future Improvement Agreement. This agreement must be
signed, notarized and approved by the City prior to issuance of a Building permit.
Future public improvements required as follows:
n n 6c. Enclosed please find your Future Improvement Agreement,
agreement signed and notarized to the Engineering Department.
Future Improvement Agreement completed by:
Date:
Please return
6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective
improvements found adjacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy.
D
O
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11 .06.030 of the Municipal Code.
7a- Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
7b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached. NOTE: The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit.
n n n
Grading Inspector sign off by:Date:
7c. Graded Pad Certification required. (Note: Pad certification may be required even
if a grading permit is not required.)
mWORD>DOCS\CHKLST\Bulldtng Ptancheck Ckl«l Form (Centric 7-14-001.doc
1ST
D
D
BUILDING PLANCHECK CHECKLIST
7d .No Grading Permit required.
7e. If grading is not required, write "No Grading" on plot plan.
MISCELLANEOUS PERMITS
8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are
not limited to: street improvements, tree trimming, driveway construction, tying
into public storm drain, sewer and water utilities.
Right-of-Way permit required for: .^___ ^_^^____
D D
n
D
a
9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153,
for assistance.
Industrial Waste permit accepted by:
Date:
10.NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit. The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas. Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first.
11. QyRequired fees are attached
No fees required
WATER METER REVIEW
12a. Domestic (potable) Use
Ensure that the meter proposed by the owner/developer is not oversized.
Oversized meters are inaccurate during low-flow conditions. If it is oversized, for
the life of the meter, the City will not accurately bill the owner for the water used.
• All single family dwelling units received "standard" 1" service with 5/8" service.
HAWORWDOCSCHKLSTlBifldlnB PUnctwck CM* fotm (Ganwt) Jtoc
BUILDING PLANCHECK CHECKLIST
1s1 )ND >RD
n n
• If owner/developer proposes a size other than the "standard", then
owner/developer must provide potable water demand calculations,
which include total fixture counts and maximum water demand in gallons
per minute (gpm). A typical fixture count and water demand worksheet is
attached. Once the gpm is provided, check against the "meter sizing
schedule" to verify the anticipated meter size for the unit.
• Maximum service and meter size is a 2" service with a 2" meter.
• If a developer is proposing a meter greater than 2", suggest the
installation of multiple 2" services as needed to provide the anticipated
demand, (manifolds are considered on case by case basis to limit
multiple trenching into the street).
12b. Irrigation Use (where recycled water is not available)
All irrigation meters must be sized via irrigation calculations (in gpm) prior
to approval. The developer must provide these calculations. Please follow
these guidelines:
1. If the project is a newer development (newer than 1998), check the recent
improvement plans and observe if the new irrigation service is reflected on
the improvement sheets. If so, at the water meter station, the demand in
gpm may be listed there. Irrigation services are listed with a circled "I",
and potable water is typically a circled "W". The irrigation service should
look like:
STA1+00 Install 2" service and
2.
3.
1.5: meter (estimated 100 gpm)
If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case
irrigation demand (largest zone with the farthest reach). Typically, Larry
Black has already reviewed this if landscape plans have been prepared,
but the applicant must provide the calculations to you for your use. Once
you have received a good example of irrigation calculations, keep a set for
your reference. In general the calculations will include:
• Hydraulic grade line
• Elevation at point of connection (POC)
• Pressure at POC in pounds per square inch (PSI)
• Worse case zone (largest, farthest away from valve
• Total Sprinkler heads listed (with gpm use per head)
• Include a 10% residual pressure at point of connection
In general, all major sloped areas of a subdivision/project are to be
irrigated via separate irrigation meters (unless the project is only SFD with
no HOA). As long as the project is located within the City recycled water
HAWOREftDOCSCHKLSTlBuMIno PtandMck Ckbt Form (Ognwtc) Joe Rtv. T/14/00
BUILDING PLANCHECK CHECKLIST
iST OND gRD
service boundary, the City intends on switching these irrigation
services/meters to a new recycled water line in the future.
Q O 12c. Irrigation Use (where recycled water is available)
1. Recycled water meters are sized the same as the irrigation meter above.
2. If a project fronts a street with recycled water, then they should be
connecting to this line to irrigate slopes within the development. For
subdivisions, this should have been identified, and implemented on the
improvement plans. Installing recycled water meters is a benefit for the
applicant since they are exempt from paying the San Diego County Water
Capacity fees. However, if they front a street which the recycled water is
there, but is not live (sometimes they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego
Water Capacity Charge. If within three years, the recycled water line is
charged with recycled water by CMWD, then the applicant can apply for a
refund to the San Diego County Water Authority (SDCWA) for a refund.
However, let the applicant know that we cannot guarantee the refund, and
they must deal with the SDCWA for this.
D D D 13- Additional Comments:
HAWORCnOOCSc>«a5T>Bi«llngPlinctwckCiditFomi(GanMc).dDC -7 Rev.T/WOO
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB
ADDRESS
DATE
RESIDENTIAL ADDITION MINOR
« $10,000.00)
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER
PLANNER DATE
ENGINEER DATE
DocsAWsforira/Plannlng Engineering Approvals