Loading...
HomeMy WebLinkAbout1387 BASSWOOD AVE; ; CB091816; Permit11-16-2009 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Electrical Permit Permit No: CB091816 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Reference #: PC#: Project Title: 1387 BASSWOOD AV CBAD ELEC 2051203600 Lot#: GROSSMAN RES-PHOTOVOLTAIC SYSTEM ON ROOF Status: ISSUED Applied: 10/30/2009 Entered By: RMA Plan Approved: 11/16/2009 Issued: 11/16/2009 Inspect Area: Applicant: JAMAR ELECTRIC STED 9830 PROSPECT AV 92071 619448-7770 Owner: GROSSMAN FAMILY TRUST 10-04-89 1387 BASSWOOD AVE CARLSBAD CA 92008 Electric Issue Fee Single Phase per AMP Three Phase per AMP Three Phase 480 Per AMP Remodel/Alteration per AMP Remodel Fee Temporary Service Fee Test Meter Fee Other Electrical Fees Additional Fees 0 0 0 0 $10.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $110.00 $0.00 TOTAL PERMIT FEES $120.00 Total Fees:$120.00 Total Payments To Date:$120.00 Balance Due:$0.00 ;LDING PLANS IN STORAGE CHED Inspector: FINAL APPROVAL / -} —/ {/ .-' 'T}Date: / ^ / ' L Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717/2718/2719 Fax 760-602-8558 www.carlsbadca.gov Est. Value Plan Ck. Deposit Date fy/jfi//^ JOB ADDRESS 1387 BASSWOOD AVENUE SUITE#/SPACE#/UNIT# CT/PROJECTff 239 PHASE # I # OF UNITS I # BEDROOMS DESCRIPTION OF WORK: Include Square Feet of Affected Areafs) * BATHROOMS TENANT BUSINESS NAME 3.5 JAY GROSSMAN CONSTR. TYPE OCC. GROUP ROOF MOUNT SOLAR PHOTOVOLTAIC SYSTEM 6.345 KW DC EXISTING USE PROPOSED USE GARAGE (SF) CONTACT NAME (If Different Fom Applicant) ADDRESS CITY STATE ZIP I PHONE FAX \ EMAIL PROPERTYOWNERNAME JAY GROSSMAN ADDRESS 1387 BASSWOOD AVE CITY STATE ZIP CARLSBAD CA 92008 PHONE FAX 760-434-4223 EMAIL shelleyvermicoast@roadrunner.com ARCH/DESIGNER NAME & ADDRESS STATE LIC. # PATIOS (SF)DECKS (SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS YES [ |# NO| | YESQNOQ YES| | N0| | APPLICANT NAME tattsr- r* A i sfmr-tn-vi-n2?A0M-A LLT tT MIKE BAUMEISTER KDDRESS CITY PHONE V SMAIL 9830 PROSPECT AVE STE D STATE ZIP SANTEE CA 92071 FAX 819-448-7770 619-448-7774 mikeb@jamarpower.com CO^RA-R BUS. NAME ifKE BAUMEISTER ADDRESS CITY PHONE EMAIL STATE LIC.# 9830 PROSPECT AVE STE D STATE ZIP CA 92071 FAX 619448-7770 619-448-7774 mikeb{8)jamarpower,c0m CLASS CITY BUS. LIC.# C10-827648 C10 918800 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior tp its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars ($500)). Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: \ 11 have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. [ill have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co MAJESTIC INS cc Poiicy No czwwmwst Expiration Date 7l'"M This section need not be completed if the permit is for one hundred dollars ($100) or less. I | Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall rpj employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure w0fl!Sks' compensation coverage is unlawful, and shall subject an/employer tacriminal penalties and civil fines up to one hundred thousand dollars (&100.000), in addition to the cost of compensation, dapages/as provided for in Section 3706^ the Labor code, interest jpd attorney's; J& CONTRACTOR SIGNATURE I hereby affirm that I am exempt from Contractor's License Law for the following reason: | | I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). | I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law). [ | I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. LT]Yes I |No 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have_£flntracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work):lavecflm i >£f PROPERTY OWNER SIGNATUREI QAGENT DATE /£) -3^ - cV "/' Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? | |Yes I iNo Is the applicant or future building occupant required to obtain a permit from the air pollution control district or airjjuality management district? I Ives I I No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? I lYes I JNo CY MAY NOT BE ISSUED EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over SO deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the BuildingOfficial under the provisions of this Code shall expire bvJimitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the/kfuiid/ig or work authorize>*y sucjijpermit is suspended of Abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). .^APPLICANT'S SIGNATURE DATE o City of Carlsbad Bldg Inspection Request For: 12/10/2009 Permit* CB091816 Title: GROSSMAN RES-PHOTOVOLTAIC Description: SYSTEM ON ROOF Inspector Assignment: 1387 BASSWOODAV Lot: 0 Type: ELEC Sub Type: Job Address: Suite: Location: OWNER GROSSMAN FAMILY TRUST 10-04-89 Owner: GROSSMAN FAMILY TRUST 10-04-89 Remarks: Phone: 6195180709 Inspectori,,/' Total Time: CD Description 34 Rough Electric 39 Final Electrical Act Comments Requested By: NA Entered By: CHRISTINE Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date Description Act Insp Comments PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB091816 DATE 10/30/09 ADDRESS 1387 BASSWOOD AV RESIDENTIAL ADDITION- MINOR (< 17,000.00) RETAINING WALL VILLAGE FAIRE POOL/SPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING OTHER SOLAR PANELS PLANNER GINA RUIZ ENGINEER DATE 11/02/09 DATE n/V**> H:\ABHIlN\COUNTEB/PUNNlNC/ENCINEERINr, APPROVALS EsGil Corporation In PartnersKip with government for Quitting Safety DATE. November 1O, 20O9 JURISDICTION: Carlsbad PLAN CHECK NO.: 09-1816 SET: II PROJECT ADDRESS: 1387 Basswood Avenue PROJECT NAME: Grossman (1) 35OO Watt & (1) 2000 Watt Solar Photovoltaic(s) JURIS a HLATfREVIEWER Q FILE X] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. - The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Jamar Electric 9830 Prospect Ave. Suite D Santee CA 92071 XI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Eric Jensen EsGil Corporationn GA n n PC Enclosures: 11/6 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 +• (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership with government for Quitting Safety DATE: November 5, 2009 a AEPU^ANT JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 09-1816 SET: I PROJECT ADDRESS: 1387 Basswood Avenue PROJECT NAME: Grossman (1) 35OO Watt & (1) 200O Watt Solar Photovoltaic(s) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. Xj The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Jamar Electric 9830 Prospect Ave. Suite D Santee CA 92071 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Rick Telephone #: 619 448-7770 Date contacted: i»' (*/o°j (by: ^ ) Fax •#: 619 448-7774 Mail Telephone u^ Fax^ In Person REMARKS: By: Eric Jensen Enclosures: EsGil Corporationn GA n EJ n PC 11/2 9320 Chesapeake Drive, Suite 208 *• San Diego, California 92123 4- (858)560-1468 + Fax (858)560-1576 Carlsbad O9-1816 November 5, 2OO9 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 1387 Basswood Avenue DATE PLAN RECEIVED BY ESGIL CORPORATION: 11/2 REVIEWED BY: Eric Jensen PLAN CHECK NO.: 09-1816 DATE REVIEW COMPLETED: November 5, 2009 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? Q Yes Q No Carlsbad 09-1816 November 5, 2OO9 ELECTRICAL 1. The addresses on the permit and the submitted plans are not the same. Please revise the incorrect one to match the correct one. 2. Inverter number 2 (garage) will need to be connected to the garage electrode system. This will require confirmation if the garage has an electrode system or not. 3. The new panelboard at the garage will also be referenced to the garage electrode system. • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Eric Jensen at Esgil Corporation. Thank you. Carlsbad O9-1816 Npvenjber 5, 20O9 /DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 09-1816 PREPARED BY: Eric Jensen DATE: November 5, 2O09 BUILDING ADDRESS: 1387 Basswood Avenue BUILDING OCCUPANCY:TYPE OF CONSTRUCTION: BUILDING PORTION Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq. Ft.) cb Valuation Multiplier By Ordinance Reg. Mod. VALUE ($) Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: PI Repetitive FeeRepeats D Complete Review $107.50 D Other pi Hourly EsGil Fee 1 $86.00 Structural Only Hr.@* $86.00 Based on hourly rate Comments: Sheet 1 of 1 macvalue.doc + Check a License or Home Improvement Salesperson (HIS) Registration - Contractors Stat... Page 1 of 1 /**« Department of Consumer Affairs "***,;,. ..t Ccbv Contractors State License Board Contractor's License Detail - License # 827648 DISCLAIMER: A license status check provides Information taken from the CSLB license database. Before relying on this Information, you should be aware of the following limitations. CSLB complaint disclosure is restricted by law (B&P 7124,6). If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below. Click on the link or button to obtain complaint and/or legal action information. Per Bi:> *iJ/': i .•', only construction related civil judgments reported to the CSLB are disclosed. Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. Due to workload, there may be relevant information that has not yet been entered onto the Board's license database. License Number: Business Information: Entity: Issue Date: Expire Date: License Status: Classifications: Bonding: Workers' Compensation: 827648 Extract Date: 10/30/2009 JAMAR ELECTRIC SAN DIEGO INC dba JAMAR POWER SYSTEMS 9830 PROSPECT AVENUE STE D SANTEE, CA 92071 Business Phone Number: (619)448-7770 Corporation 11/20/2003 11/30/2011 This license is current and active. All information below should be reviewed. CLASS I DESCRIPTION C10 CONTRACTOR'S BOND This license filed Contractor's Bond number 191439 in the amount of $12,500 with the bonding company AMLRiCAN CONTRACTORS INDEMNITY COMPANY. Effective Date: 01/01/2007 Contractor's Bonding History BOND OF QUALIFYING INDIVIDUAL 1. The Responsible Managing Officer (RMO) PHILIP ANTHONY EDWARDS certified that he/she owns 10 percenter more of the voting stock/equity of the corporation. A bond of qualifying individual is not required. Effective Date: 11/20/2003 This license has workers compensation insurance with the MAJESTIC INSURANCE COMPANY Policy Number: C20090709701 Effective Date: 07/01/2009 Expire Date: 07/01/2010 Worke!$' Cornpenssiion History Personnel listed on this license (current or disassociated) are listed on other licenses. Conditions of Use | Privacy Policy Copyright © 2009 State of California https://www2.cslb.ca.gov/OnlineServices/CheckLicense/LicenseDetail.asp 10/30/2009 • Powered PVP1100 to PVP5200 String Inverters » 3 Example of Side-by-side Flush Mounting on 16" Intervals 150 SW Scalehouse Loop Bend OR 97702 1-541-312-3832 WWW.PVPOWERED.COM Proven Reliability - Now With An Integrated AC and DC PV System Disconnect PV Powered continues to deliver industry leading reliability and technical innovations that lower the cost of installation. The addition of a factory-integrated AC and DC PV System Disconnect that exceeds UL and NEC requirements is exactly what you have come to expect from PV Powered. Our inverter architecture with deep software integration and significantly lower parts count is the foundation of PV Powered's industry-leading reliability. Validated by sophisticated reliability modeling and rigorous endurance testing we are confident in our claim of lowest lifetime cost. The new integrated PV System Disconnect reduces total installation interconnects from 15 to 5, eliminating common failure points. Optimally placed knockouts provide a variety of conduit routing options with minimized bending requirements further saving on installation time and material costs. Our robust testing of the switch mechanism to UL 98 standards ensures inspector approval. PV Powered's string inverters are backed by the industry's first nation-wide ten year warranty and a service reimbursement program unparalleled in the industry. Optional performance monitoring is available which includes low cost, secure web-based access to your system's status and performance history. FEATURES Industry-Leading Reliability • Endurance tested to 20 year operating life • Significant software integration versus complex hardware design • Lowest part counts and fewest interconnects eliminate common failure points • Field-proven with thousands of units installed nationwide Integrated AC and DC PV System Disconnect • Robust testing of switch mechanism to UL98 standard ensures inspector approval • Single AC and DC switch visible and lockable in the OFF position • Internal wire raceway isolates the conductors for each circuit, AC, DC, and LV DC communications • Internal wire raceway easily accommodates up to four inverters side-by-side • UL 98 and NEC 690 compliant • Direct-to-wall surface enclosure mounting design allows for easy back entry installation Easy Installation • Factory integrated inverter and PV System Disconnect eliminates the need for extra equipment • Interconnections reduced from 15 to 5 points, saving installation time and material costs • Field-configurable inverter grounding scheme with simple jumper selection • Optimally placed knockouts for a variety of conduit routing with minimized bending Installer-Focused Support • No special clubs or purchase requirements to get the best technical support in the industry • Live phone support • $ 150 service reimbursement that sets the industry standard for RMA compensation • Optional performance monitoring available DIMENSIONS 1 PVP1 100 to PVP3500 ji © ™ [—- 4 3/8" -"• [— 6 1/2' «• BOTTC • © '/jS .^DRAINAGE PORT r -U — •* — | ^3 1/8"-'"^ : 1 PVP4600, PVP4800, PVP5200 -ptil © ' £-? t?H r (— - 4 3/8" -- -. 7 3/4" ELECTRICAL MODEL ^ ® s- $=i ^ « / /~MT3I*'K.C>, /\, s~ DRAINAGE PORT S 3 1/8" [—- 4 \IT — —V <?, U-LBM SPECIFICATI 0 JJJ____^ lllllllllll' S x ,j 1 VIL •= ' T 1 :B BB _ ___^ ! « JI 1 I • • | j ru ' ^ Ji •' A ~/~T . , y. .1 . / . . o * o £•,,„_: u_: r -j ^^~UJ =• -^^v ^A o o o — oo -T,, £"'" — — T { XL i_ T I 1 'L PVP1100 PVP2000 PVP2500 PVP2800 PVP3000 PVP3500 PVP4600 PVP4800 PVP5200 IB— - — ^^^^— — - — «^ — ^~- — ~— • Continuous Output Power (watts) 1100 2000 2500 2800 3000 3500 4600 4800 5200 Weighted CEC Efficiency (%) 90.5 92 94.5 92 93.5 95.5 95.5 96 96 Maximum DC Input Voltage (VOC) 500 500 500 500 500 500 500 500 500 DC Voltage Operating Range (V) 115-450 115-450 140-450 180-450 170-450 200-450 205-450 200-450 240-450 DC Minimum Start Voltage 130 130 155 195 185 215 220 215 255 DC Isc Maximum Current (A) 26 26 26 26 26 26 48 48 48 DC Imp Nominal Current (A) 10 18 20 16 18 18 25 26 25 AC Maximum Continuous Current (Amps) 10 10 12 14 13 15 23 23 23 AC Nominal Voltage (V) 120 240 240 208 240 240 208 240 240 AC Output Voltage Range (V) 105.6-132.6 211-264 211-264 183-229 211-264 211-264 183-229 211-264 211-264 AC Frequency Range (Hz) 59.3-60.5 59.3-60.5 59.3-60.5 59.3-60.5 59.3-60.5 59.3-60.5 59.3-60.5 59.3-60.5 59.3-60.5 MECHANICAL SPECIF CATIONS MODEL PVP1100 PVP2000 PVP2500 PVP2800 PVP3000 PVP3500 PVP4600 PVP4800 PVP5200 HI Inverter with Factory-Integrated AC and DC PV System Disconnect NEMA 3R Steel Enclosure Wall Mounted with Bracket Included Weight (Ibs) 55 65 70 70 80 85 135 135 135 Inverter with Disconnect Dimensions 30 3/8" H 30 3/8" H 30 3/8" H. 30 3/8" H 30 3/8" H 30 3/8" H 35" H 35" H 35" H x155/8"W x155/8"W x155/8"W x155/8"W x155/8"W x155/8"W x181/8"W x181/8"W x181/8"W x81/4"D x81/4"D x81/4"D x81/4"D x81/4"D x81/4"D x85/8"D x85/8"D x85/8"D AGENCY APPROVALS MODEL PVP1100 PVP2000 PVP2500 PVP2800 PVP3000 PVP3500 PVP4600 PVP4800 PVP5200 UL98 13th Edition, Enclosed and Dead-Front Switches, UL 1741 Nov 2005 Revision, IEEE 1547 Compliant, FCC Class A& B . - ,.^,,M«^«»gg^g__H«.__«««H««IHH^»| O2009 Pv Powered , 020609 • I Yl235P~29b/1650x990SERIES YINGlillSeLAR Power Your Life YL235P-29b . YL230P-29b. YL225P-29b YL220P-29b . YL215P-29b . YL210P-29b ABOUT YINGLI SOLAR Yingli Solar is a vertically integrated manufacturer of solar photovoltaic modules. Under one roof we manufacture our ingots, wafers, cells and modules. This ensures that we can tightly control our material and production quality, offering our customers leading product durability and sustainable performance backed by our 25 year limited power warranty*. PERFORMANCE » High efficiency, polycrystalline solar cells with high transmission and textured glass delivering a module series efficiency of up to 14.4%, minimising installation costs and maximising the kWh output of your system per unit area. » Power tolerance of +/-3% minimising PV system mismatch losses. QUALITY & RELIABILITY » Robust, corrosion resistant aluminium frame independently tested to withstand wind loads of 2.4KPa ensuring a stable mechanical life for your modules. » Take confidence in our modules with a 5 year limited product warranty and a 25 year limited power warranty*. » Modules protected by box during transportation and with 20 modules in a box on-site waste is minimised. » Modules independently tested to ensure confor- mance with certification and regulatory standards. » Manufacturing facility certified to IS09001 Quality Management System. WARRANTIES 5-year limited product warranty* Limited power warranty*: 10 years at 90% of the minimal rated power output, 25 years at 80% of the minimal rated power output QUALIFICATIONS AND CERTIFICATES IEC61215, IEC61730, UL1703, Class C Fire Rating, IS09001 ' In compliance with our Warranty Terms and Conditions •'00886*%* ISO 9001 2000 www.ylnglisolar.com YL235P-29b/1650x990SERIES ELECTRICAL PARAMETERS IV CURVES o I Electrical parameters at STC (1000 W/m', 25 "C, AM 1.5 according to EN 60904-3) current [A] Module type YL235-29b YL230P-296 YL225P-29b YL220P-29b YL215P-29b YL210P-29b Power output [W] 235.0 230.0 225.0 220.0 215.0 210.0 Power output tolerances [%] */- 3 +/- 3 */- 3 «/- 3 */- 3 +/-3 Module Efficiency [%] 14.4 14.1 13.8 13.5 13.2 12.9 Voltage at Pinax, V.,, [V] 29.5 29.5 29.5 29.0 29.0 28.5 Current it Praax,!.,, [Al 7.97 7.80 7.63 7.59 7.41 7.37 Open circuit voltage V_ [V] 37.0 37.0 36.5 36.5 36.0 36.0 Short circuit current 1 [A] 8 54 6 40 8 28 8 15 8 10 7 95 Max. system Voltage (VI 1 EC: 1,000 V DC ; UL: 600V DC Parameters of the- thermal characteristics NOCT (Nominal Operating Cell Temperature) [°c] 46 »/- 2 Temperature coefficient of the short circuit current lu [%/K] * 0.06 Temperature coefficient of the open circuit voltage V,, [%/K] - 0.37 Temperature coefficient of the MPP power P^ [%/K] • 0.45 MECHANICAL PARAMETERS Thickness with junction box [mm] 50 E , E| — 0 5 10 IS 20 — lOOOW/m' — 600W/m! — 800W/m! — 400W/m! 990mm 946mm f Grounding holes 2-06 mm e Mounting slots 4-8x6.5 mm Drainage holes 8-04 mm gf e 1 oo it A " ~~ X, . \\ v x \\ \ N\ \ W\ a 30 35 1020 mm\71A 1650mmvoltage IV] 40 50mm I 1650 mmWeight [ko] Junction box (manufacturer/protection degree/number of diodes) Junction box dimensions (length/width/thlckness [mm]) Positive cable (manufacturer/length [mml/cable cross-section [mm1]) Negative cable (manufacturer/length [mml/cable cross-section [mm2]) Plug connector (manutacturer/type/protection degree) Front cover (material/thickness [mm]) CHI type (quantity/technology) Encapsulation materials Rear cover (material/thickness [mm]) Frame (material) OPERATING CONDITIONS Operating temperature [°C1 Max. wind load [Pa] PACKAGING Number of modules per box Box size (length [mml/wldth [mml/depth [mm]) Box Gross weight in Kg Boxes per pallet 1 The data does not refer to a single module and they are not part of the offer, they serve for comparison only to different module types. 19.8 CiXi/IP65/6 151/122/25 TAIYO/1200/4 TAIYO/1200/4 MC4 / UV resistance and self-locking / IP65 Tempered Class, 3.2mm 60/polycrystallme/156 1156 Ethylene Vinyl Acetate (EVA) Le/PET/PVDF,0.287 robust anodized aluminum alloy 12mm 32mm - 40 to »85 2.4K 20 1700/1140/1165 450 1 SECTION A-A Electrical equipment, check with your installer DC Power Systems (800)967-6917 w/vw.dcpower-systems.com Yinqli Energy (China) Company Limited commerceiyinqlisolar.com 0086 • (0)312 • 8929802 www.yingllsolar.com Subject to modifications and errors YINGUIKGLARTR? Power Your Life CLICKSYS INSTALLATION MANUAL v.1.0 © 2009 by Unlrac, Inc. All rights reserved, Pub 090501-lii, May 2009 UNIRAC 1411 Broadway Boulevard NE Albuquerque NM 87102-1545 USA www.clicksys-beam.com PV Quick Mount (1) 5/16" x 3-1/2" Stainless Steel Lag Bolt (1)5/16" Sealing Washer (1)5/16" EPDM Washer (1) 1 Flange Connection INSTALMNC5 Step 1: Attach beam to 2 Flange Connection or 1 Flange Connection A NOTE: Always engage one side before clicking connection into beam. NOTE: Do not use connection if the engagement features on the connection are bent or damaged. Beam Step 2: Attach 2 Flange Connection or 1 Flange Connection to rafter /|\ NOTE: When using 2 Flange Connection w/Butyl Pad, remove liner before installing screws. 2 Flange Connection Option 1 Flange C^tnection Op UNJRAC CLICKSYS Engineering Report Engineering Variables Description Building Height Roof Pitch Wind Exposure Category Importance Factor Basic Wind Speed Effective Wind Area Topographic Factor Roof Zone Design Wind Load Calculations based on Description Net Design Wind Pressure (Uplift) Net Design Wtnd Pressure (Downforce) adjustment factor for height and exposure category Design Wind Load (Uplift) Design Wind Load (Downforce) Variable h I V vasu* 530 0-45 C 1 85 50 1 1 Unts ft degrees mph ft2 ASCE 7-05 Method 1 VanabS® Prxoo (Uplift) P«»f3o (Downforce) Port Value -122 11.1 1.4 -17.08 15.54 UfMS psf psf psf psf Dead and Snow Loads Da scrip! ion Dead Load Flat Roof Snow Load Variable Pi Value 3.1 0 UltAS psf psf Load Combinations Calculations Description Value Um5s Combination 1: Dead + 0.75 x P^Downforce) + 0,75 Combination 2: Dead + Pw,( Down force) Combination 3: Dead + Snow Combination 4: 0.6 x Dead + P^Uplift) x Snow 14.76 1864 3.1 -1522 psf psf psf psf Distributed Load Calculation Description Maximum Absolute Value of Load Combinations Module Length Perpendicular to Rails Distributed Load (Uplift) Distributed Load (Downforce) Variable P B w w Value 1864 5.42 -41.22 50.48 Units psf ftpifpjf Rail Span Information Description Allowable Span VariaWe L Va?yo 54 Units inches Point Load Calculations Description Attachment Point Load (Uplift) Attachment Point Load (Downforce) Varuc -185.5 227.2 Units Ibs Ibs The design is based on and in compliance with the following codes/standards: 1. 2007 California Building Code (CBC), based on the 2006 International Building Code, by International Code Council, Inc., 2006. 2. Aluminum Design Manual: Spe^ificajjpji$v9.rKl_Guideiines for AluminumJSjructufes, by The Aluminum Association, Washington, D.C., 2000. Installation of products related to this engineering report is subject to the requirements below; • Flush roof installations only • Module must not be placed in roof overhang zone (must be in roof zone 1) • Roof slope must be 0 - 45 degrees (0/12 - 12/12 pitch) • Installation must have at least 4 modules grouped together (minimum 50 ft2} • Module dimensions must be less then 40" x 65" • Surrounding ground area must not slope more then 10 degrees • Location must fall into Wind Exposure Category B or C « Building height must be less than or equal to 30'0" THIS IS A SAMPLE OF THE PLAQUE OR DIRECTORY REQUIRED WHEN THERE IS ANY ALTERNATE SOURCE OF POWER CONNECTED TO THE PREMISES WIRING SYSTEM. THE EXAMPLE BELOW SPECIFIES PHOTOVOLTAIC OR WIND GENERATION. MODIFY AS REQUIRED TO DEPICT THE GENERATING FACILITY(S) TO BE INSTALLED. CAUTION 3/4" POWER TO THIS BUILDING IS ALSO SUPPLIED}-i/4 FROM THE FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS SHOWN UTILITY SERVICE PV SYSTEM DISCONNECT FOR UTILITY OPERATION EMERGENCY ]-l/8" GENERATOR BUILDING WIND TURBINE ON ROOF OR SHOW LOCATION IF REMOTE FROM BUILDING STORAGE BATTERIES ' IN GARAGE / ROOM 123 SOLAR PHOTOVOLTAIC ON ROOF WIND TURBINE REMOTE LOCATION- PER ZONING REQUIREMENTS PLAQUE SPECIFICATIONS THE PLAQUE OR DIRECTORY SHALL BE METAL OR PLASTIC, WITH ENGRAVED OR MACHINE PRINTED LETTERS, OR ELECTRO-PHOTO PLATING, IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP- RIVETS, SCREWS. PLAQUES (SAMPLE) DOC 7-26-06 Jay Grossman Roof Mount Solar Photovoltaic System 1$87 Basswood Avenue Carlsbad, CA 92008 760-434-4223 - 6,345 DC Watts NJ /— ELECTRICAL SERVICE & PV UTILTY DISCONNECT INVERTER 42 PVP2000 — INVERTER IP I PVP3500 L o01o (0 o UJ S fl I I ! !51 Q CD•4-j 'ID CO 0 C CD h- h- i CO LT) CO O5 §.3 x £cd g <]^ o3S Q. <go o 8 ° SCO COO) C7D NN CO o% u_J .M o o 2 oo o 11 NOTES: « i p.* 1 THIS PROJECT SHALL COMPLY WITH THE ART. 690 2007 CALIFORNIA BUIDUNG COD^ WHICH ADOPTS THE 2006 IBC, 2006UNC, 2006 UPC AMD THE 2005 NEC. 1. THE SOLAR PHOTOVOLTAIC SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ART £90 OF THE 2007 CEC 3 AT THE EXISTING SDG&E ELECTRICAL SERVICE A PERMANENT WEATHERPROOF PLACARD THAT STATES THE FOLLOWING: THIS ELECTRICAL SERVICE IS ALSO SERVED BY A PHOTOVOLTAIC POWER SOURSE. THE ELECTRIC SERICE DISCONNECT IS 1 OF 2 SERVICE DISCONNECTS.. Parcel #2051203600 1966 - 2,600 SQF - 3 BED 3.5 BATH TCT 239-TR 1681 4 AT THE NEW PHOTOVOLTAIC DISCONNECT THAT IS MOUNTED ADJACENT TO THE EXISTING SDC&E ELECTRICAL SERVICE PLEASE PROVIDE A PERMANENT WEATHERPROOF PLACARD THAT 5TATE5 THE FOLLOWING: THIS IS A PHOTOVOLTAIC DISCONNECT. THIS IS 1 OF 2 SERVICE DISCONNECTS 5 THE SUM OF THE AMPERE RATINGS OF OVERCURRENT DEVICES SUPPLYING POWER TO THE BUSSBARS OR BUSS CONDUCTORS SHALL NOT EXCEED 120 PERCENT OF THE RATING OF THE BUS5BAR OR CONDUCTOR 6. SDG te. E MUST BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION ELECTRICAL SINGLE LINE DIAGRAM 27 YINGLI YL235-29b 235W MODULES WIRED IN 3 STRINGS OF 9 MODULES TO PVP3500SD AND PVP2000SD INVERTERS SYSTEM: CEC kW AC 5.192 MODULES: PM=235W ISC= 8.54A IPM= 1.91 A. VPM=29.5V VOC=37.0V JAY GROSSMAN RESIDENCE 6160 DC WATT SOLAR PV ARRAY ROOF MOUNTED 1387 BASSWOOD AVENUE CARLSBAD, CA 92008 760.434.4223 JAMAR ELECTRIC SAN DIEGO 9830 PROSPECT AVE STE D SANTEE,CA 92071-43 75 (619)448-7770 FAX (619) 448-7774 LIC #C10-827648 Designed by: TYPICAL STRING OF 9 MODULES PVP3500SD INVERTER 15AMPS@ 240VAC PVP2000SD INVERTER 10AMPS@ 240VAC #8 THWN-2 CU L1.L2 #8 THWN-2 CU GROUND IN 3/4" NM CONDUIT#10 THWN-2 CU & #8 THWN-2 GROUND IN 3/4" EMT CONDUIT LABEL "CAUTION DC CIRCUIT" 125AMPMLO LOADCENTER 200AMPMATN C/B \v/ 200AMP BUSSINGINTEGRATED DC COMBINER 60AMP 240V PV SOLAR UTILITY DISCONNECT #10THWN-2CU L1.L2 #8 THWN-2 CU GROUND IN 3/V' NM CONDUIT 125 AMP MLO LOADCENTER DETACHED GARGAE TO 6XlSTfOb#8AWG DC SYSTEM GROUND TIE TO «0006;10!«M£MSTING GROUNDING ELECTRODE