Loading...
HomeMy WebLinkAbout1391 Oak Ave; ; CBR2017-2957; Permit(city of Carlsbad Residential Permit Print Date: 04/23/2018 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 1391 Oak Ave BLDG-Residential 2050201800 $74,824.48 Work Class: Addition Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Description: MATSUBARA: 132 Sf ADDITION (CONVERTING PATIO TO DEN)// 40 SF REMODEL// REROOF BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Owner: TEMUJIN 5 M MATSUNBARA 1391 Oak CARLSBAD, CA 92008 760-458-3129 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MANUAL BUILDING PLAN CHECK FEE MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL 581473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM Total Fees: $1,530.21 Total Payments To Date: $1,530.21 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020{a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES 1T APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Permit No: CBR2017-2957 Closed -Finaled 12/11/2017 01/22/2018 PBurn 4/23/2018 11'15:40AM $0.00 $516.75 $61.84 $43.00 $170.00 $299.89 $52.00 $80.00 $3.00 $9.73 $238.00 $56.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING D ENGINEERING 0BUILD1NG DFIRE 0HEALTH D HAZMAT/APCD {"city of Building Permit Application Plan Check No. Ci>O ., ,-, 1 7 -::l"'t 5 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value '-1'1..~,'3"1. Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit • email: building@carlsbadca.gov Date r'l~l t-•-i ISWPPP www.carlsbadca.gov JOB ADDRESS SUITEI/SPACEI/UNITI APN 2..os -O;}-u -\ <j{ -OU l ::,q l 0~ "'" t, CT/PROJECT# ILOT# lPHASE # I# OF UNITS I# BEDROOMS # BATHROOMS 1 TENANT BUSIN~ NAME I CONS TR. TYPE I occ. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) tv den) i?~ S,,·· ~\. a..<i{,t<.><' OEri Cc.onve.rt po-:J-1 b 40t>F Rer-rmd -t ~ EXISTING USE I PROPOSED USE I GARAGE (SF) PATIOS (SF) I DECKS (SF) FIREPLACE lAIR CONDITIONING I FIRE SPRINKLERS YES[]# No(:] YES[]No[J YES[]No[J APPLICANT NAME"'{" \. ' -. -I_, PROPERTY OWNER NAME 1' t.,,, .,. , .. K' ' Prh"II"' Cnn•-D • ... W, ~ • .,._ "' ..,~ ADDRESS ADDRESS ~ \ ?:.oj I n "I<-A.vt. \°'YI\ 0 "J<.-Av~ CITY (."''I e, !,, ......{ STATE ZIP CITY J STATE ZIP CA '3 )-17 0 js lcu{<,I, C.-4 ', }-ocY PHONE IFAX PHONE I FAX 1 Coo· "~" · 3,\ },"l -q-r.,o -,4<;[{ -31 ~C/ EMAIL -\-'vvt,"*'S"'fv,cf .i.. ,\-r.] 11,>"l,.,I , LGV't EMAIL A-I --1---~,J,....<t<, ~!j-r,,otM • C..0"'1\ DESIGN PROFESSIONAL }-,\1ll,,"' ... \ °l<0!-1-Cv-J CONTRACTOR BUS. NAME ADDRESS (a.,,,11.W 'f-J... ADDRESS ;}-). ]-I., CITY l11vtl~ STATE CA ZIP CJ)..oor CITY STATE ZIP PHONE -3 "'f ;21,, I FAX PHONE IFAX -{(p O , '1-o-., EMAIL VVI, ~<O':>t<..J /,.) t,..,,+_....,,( EMAIL • l. &iv"-I STATE LIC. # STATE UC.# I CLASS I CITY BUS. UC.# (Sec, 7031.5 Business and Professions Code: Any City or County which requires a permit to construct. alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law JChapter 9, comme_nding with Section 7000 of D1v1s1on 3 of the s.usiness and Professions Code} or that he is exemP.t therefrom, and the basis for the alleged exemption. Any violation of Section 031.5 by any applicant for a permit sub1ects the applicant to a civil penalty of not more than five hundred dollars {$5001). WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: B I have and will maintain a certificate of consent to self-insure for workers' compensa~on as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as reQUired bv Sec~on 3700 of the LaOOr Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. _____________________ Policy No.--------------Expiration Date _________ _ ~section need not be completed if the permit is for one hundred dollars ($100) or less LJ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code, Interest and attorney's fees. Ji5 CONTRACTOR SIGNATURE 0AGENT DATE OWNER-BUILDER DECLARATION I heteby affirm that I am exempt from Contractor's Ucense Law for the following reason: ED D D I, as owner of the property or my employees with wages as their sole oompensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not inter.ded or offered for sale. II, however, the building or improvement is sold within one year of oompletion, the owner-builder will have the burden of provir,g that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and oontracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0Yes 0No 2. I (have I have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the prop:ised construction (include name address I phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number) 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work): Ji5 PROPERTY OWNER SIGNATURE 0AGENT DATE I ~Li I 6-::; _____ __:__g_+,_._.~,._._i__ I COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, ocutely hazardous materials registration form or risk management and prevenUon program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substar.ce Account Act? D Yes Cl No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D Yes O No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes D No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I oortlfy that I have read the application and state that the above infonnatlon is correct and that the lnfonnation on the plans Is accurate. I agree to complyv.tth all Cl1y ordnances and State laws relating to bulldngconstructlon. I hereby authorize representative of!he Qty of Cartsbad to enlef uJX)n the aoove mentioned property br inspocton purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CllY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permtt is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Buikling Official under the provisions of this C:OOe shall e)(J)ire by limitation and become null and vod if the buikling or'M'.ll'k authorized by such permtt is not commence:! within 180 days from the date of such pennit or if!he buikling or 'M'.ll'k auloorized by 5001 permtt is suspended or abandoned at any time after the 'M'.ll'k is commence:! for a period of 180 days (Section 106.4.4 Unibrm Buikling Cocle). ~ APPLICANT'S SIGNATURE ~~ -'----"=i---'-'+-L.1-:;'---____________ _J PERMIT INSPECTION HISTORY REPORT (CBR2017-2957) Permit Type: BLDG-Residential Application Date: 12/11/2017 Owner: TEMUJIN MATSUNBARA Work Class: Addition Issue Date: 01/22/2018 Subdivision: CARLSBAD LANDS Status: Closed -Finaled Expiration Date: 09/24/2018 Address: 1391 Oak Ave Carlsbad, CA 92008-1932 IVR Number: 8259 Scheduled Actual Complete Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection 02/21/2018 02/21/2018 BLDG-SW-Pre-Con 049328-2018 Passed Paul Burnette Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 02/27/2018 02127/2018 BLDG-11 049942-2018 Passed Paul Burnette Complete Foundatlon/Ftg/Pler s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03/01/2018 03/0112018 BLDG-66 Grout 050204-2018 Passed Paul Burnette Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03/08/2018 03/08/2018 BLDG-15 051018-2018 Passed Chris Renfro Complete RooffReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Inspected roof framing members, blocking Yes with ventilation holes, and mechanical connectors. Ok to install insulation and roof sheathing. 03/09/2018 03/09/2018 BLDG-15 051249-2018 Passed Paul Burnette Complete RooffReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03/1412018 03/14/2018 BLDG-13 Shear 051665-2018 Passed Paul Burnette Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-24 051664-2018 Failed Paul Burnette Re inspection Complete Rough/To pout Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-34 Rough 051666-2018 Failed Paul Burnette Relnspection Complete Electrlcal Checklist Item COMMENTS Passed BLDG-Building Deficiency No 03/16/2018 03/16/2018 BLDG-84 Rough 052078-2018 Passed Mlchael Collins Complete Combo(14,24,34,44) April 23, 2018 Page 1 of 2 ______ .__, __ _ PERMIT INSPECTION HISTORY REPORT (CBR2017-2957) Permit Type: BLDG-Residential Application Date: 12/1112017 Owner: TEMUJIN MATSUNBARA Work Class: Addition Issue Date: 0112212018 Subdivision: CARLSBAD LANDS Status: Closed -Finaled Expiration Date: 09/2412018 Address: 1391 Oak Ave Carlsbad, CA 92008-1932 IVR Numbor: 8259 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency See card for notes. Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLOG-34 Rough Electrical Yes 03/19/2018 03/19/2018 BLDG-16 Insulation 052098-2018 Passed Michael Collins Complete Checklist ltetn COMMENTS Passed BLDG-Building Deficiency Walls. Yes 03/28/2018 03(28/2018 BLDG-82 Drywall, 052983-2018 Passed Paul Bumette Co,nplete Exterior Lath, Gas Test, Hot Mop Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-17 Interior Lath-Drywall Yes BLDG-18 Exterior Lath and Yes Drywall BLDG-23 Gas-Test-Repairs Yes 04123/2018 04/23/2018 BLDG-Final 055778-2018 Passed Paul Burnette Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes April 23, 2018 Page 2 of 2 City of Carlsbad cbR2017-2957 Dec 21, 2017 «~ ,D J:.D~e~v~ew~m:.!.!!ie..tn.ut'"'S:!.e!E.!..rv11:.1~· c:.se~s SPECIAL INSPE'fli:5ftEfV BuildingDivision '~ CITY OF AGREEMENT 1635FaradayAvenue CARLSBAD B-45 JAN 5 2018 160-602-2119 www.car1sbadca.gov CITY OF CARLSBAD In accordance with Chapter 17 of the California Building Code the folloWlng must tie co requires special Inspection, structural observation and construction material testing. when work being performed A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check~ you are owner-Builder i;g. (If you checked as owner-builder you must also complete Section B of this agreement) Name: !Please prtntl ..... ~i':1:1.0 I J_ .................. -. .. ---······· ______ t".'L~~ .. . {Finl) (M. J j [Ut-~!) Mailing Address: 1~.'i.L .. Qp.~---..Allf:.. .. , ~AQ .. ~-__ ';)),.oo ·"··············· ..... EmaiLl~-rr,v<-12~_Qe:c~11,,c_, <ccovt .. Phone: 4 (,,,9-4~&"= ~I ;;t'l I am· !<:!_Property Owner CJProperty Owner's Agent of Record CJArohltect of Record CJEnglneer of Record State of Galifornia Registration Numbec..·-----------Expiration Date: _______ _ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the state of California, that I have read, understand, acknowledge and promise lo comply with the City of Carlsbad requirements for special inspections, structural obse1Va!ions, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. Signature· ,1 __ --_< -· 14,,,~ ........................ Date: I I~ R. ~~L#'f"~... 7 B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder I owner-builder. Contractor's Company Name: _________________ Please check if you are OWner-Builder Cl Name: (Plea.., print) ·---····· ·······-··:·:··:·:············---··--····--········· ·:.-:·.·:·············· -------···-···········-·· ·.,-·,·············------···------··· \f;ir;,tJ \l$~) Mailing Address: ________________________________ _ PhOne: .... -----·-· .......................... . state of Galifornia Contractor's License Number_· ---------Expiration Date: ------- • I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have in-place procedures for exercising control within our (the contractor's) organiZation, for the method and frequency of reporting and the distribution of the reports; and • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. • I will provide a final reporl I letter in £Ol11Pliance with CBC Seq/on 1704.1.2 prior to requesting final Inspection. Signature4.,, .'.'~/~ ~ Date: / /s:-,_,_b_..,.g:'-------~ I 9.45 Page 1 of 1 Rev. 08/11 Structural Inspections LLC *SPECIAL INSPECTION SERVICES* P.O. Box 2415 El Cajon, CA 92021 Cell: (619) 770-9559 • Fax (619) 588-5955 Project Name,{Qo._-\-°S\A.bJc., Inspection Report 'be c\ (Wm CjclJ, Page: ____ of Report#:~----- Permit #,------'c'=----?.i_:__Q_L_O_\__c_7_~_2_C,_')"_I __ Project Address: ______________________ _ Architect, (\e,s: J"' 6'J (r\ ; c.J,,a 9 I File#:----------------- Engineer: ________________________ _ DSA#, _______________ _ Contractor· Other· INSPECTION MATERIAL SAMPLING QTY MATERIAL DESCRIPTION INSPECTION CHECKLIST --Structural Steel --H.S. Bolts -----H.S. Bolts ..?..--Plans/Specs __ Masonry --Prisms ---Cone. PSI Clearances ---- --Concrete --Mortar/Grout -----Grout PSI --Positions __ Fireproofing Cone. Cylinders Mortar PSI .,..-· -------__ Sizes ./' Epoxy --Fireproof ~ Steel ;ti '1 __ Laps --Other: --Other: -----Elect./Wire --Consolidation --Other: --Other: -----Fireproof __ Torque Ft. Lbs: Other: Other: ~ Other: -g ' Jv, 4£ <' _-Otherc '2 ") 0 l) ---------', rvi'<~" ,, 1' Other: Other: / ' Other: Other: <:1ec,ol :tl t.\ u\ ho•~ CERTIFICATION OF COMPLIANCE: All reported work. unless otherwise noted, complies with approved plans, specifications and applicable sections of the building codes. This report covers the locations of the work inspected and does not constitute opinion or project control. I hereby certify that I have observed to the best of my knowledge all of the above reported work unless otherwise noted. I have found this work to comply with the approved plans, specifications, and applicable sections of the governing building laws. Inspector: GIANNI BATTAGLIA Cert: ICC 8219469 j 1.~sp:_Date: Time Start: Time Stop: Approved By: __________________ _ Project Superintendent :Day r//~ ~- Signature Day.~.=. Day S: DATE: Jan 16, 2018 JURISDICTION: City of Carlsbad PLAN CHECK#.: cbR2017-2957 PROJECT ADDRESS: 1391 Oak Ave. ~ EsG1I SET II D APPLICANT /!f JURIS. PROJECT NAME: Addition, Remodel and Reroofing for Matsubara Residence ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: f!) Telephone#: Date contacted: (by;..-H Email: Mail Telephone D REMARKS:. By: Rich Moreno EsGil Fax In Person Enclosures: Jan 9, 2018 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ' DATE: Dec 21, 2017 JURISDICTION: City of Carlsbad PLAN CHECK#.: cbR2017-2957 PROJECT ADDRESS: 1391 Oak Ave. ./. EsG1I A SAFt.bu1lt Company SETI D_.>PPLICANT _.....el" JURIS. PROJECT NAME: Addition, Remodel and Reroofing for Matsubara Residence D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. t:8J The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. t:8J The applicant's copy of the check list has been sent to: Michael Trosrud D EsGil staff did not advise the applicant that the plan check has been completed. t:8J EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Michael Trosrud Telephone#: 760-707-3726 Date contacted:(1/(1-\ (byy\o Email: m.trosrud@hotmail.com ~ail./' Telephone Fax In Person t:8J REMARKS: City to verify permit. 132 sq-ft Addition, 40-ft Remodel. By: Rich Moreno EsGil Dec 14, 2017 Enclosures: 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad cbR2017-2957 Dec 21, 2017 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: cbR2017-2957 PROJECT ADDRESS: 1391 Oak Ave. FLOOR AREA: Addition: 132 sq-ft Remodel: 40 sq-ft Re-roofing: 288 sq-ft REMARKS: DATE PLANS RECEIVED BY JURISDICTION: Dec 11, 2017 DATE INITIAL PLAN REVIEW COMPLETED: Dec 21, 2017 FOREWORD (PLEASE READ): JURISDICTION: City of Carlsbad STORIES: 1 HEIGHT: 12-ft ( C.R.C.) DATE PLANS RECEIVED BY ESGIL CORPORATION: Dec 14, 2017 PLAN REVIEWER: Rich Moreno This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad cbR2017-2957 Dec 21, 2017 • PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans to once again be signed by the person responsible for their preparation on re-submittal. (California Business and Professions Code). 3. Specify on the Title Sheet of the plans the gross floor area of each element of this project, including dwelling, garage, carport, patio, deck and balcony. Section R106.2. • FIRE PROTECTION 4. Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. 5. Projections, including eaves, must be at least 24" from a property line. Table R302.1. 6. Show locations of permanently wired smoke alarms with battery backup, per Section R314: a) Inside each bedroom. b) Outside each separate sleeping area in the immediate vicinity of the bedrooms. c) On each story, including basements. d) Such smoke alarm locations shall comply with the following: i) They shall be not less than 3' from the door opening of a bathroom. ii) They shall be at least 20' from a cooking appliance. iii) They shall be at least 3' from supply registers of heating/cooling systems. City of Carlsbad cbR2017-2957 Dec 21, 2017 iv) They shall be at least 3' from the tip of the blade of a ceiling- mounted fan. • NOTE: When more than one smoke alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. 7. In existing buildings, when alterations, repairs or additions requiring a permit occur (or when one or more sleeping rooms are added), the dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R314.8.1. 8. In dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), show the locations of permanently wired carbon monoxide alarms with battery backup, per Section R315: a) Outside each separate sleeping area in the immediate vicinity of the bedrooms. b) On each story, including basements. • NOTE: When more than one carbon monoxide alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. 9. When alterations, repairs or additions are proposed for dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), the dwelling unit shall be provided with carbon monoxide alarms located as required for new dwellings; the carbon monoxide alarms shall be interconnected and hard wired. Exception: Carbon monoxide alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R315.2. • ROOFS 10. Specify on the plans the following information for the roof materials, per Section R106.1.1: a) Manufacturer's name and product name/number. b) ICC approval number, or equal. 11. Specify roof slope on the plans. City of Carlsbad cbR2017-2957 Dec 21, 2017 12. Note roof and wall insulation R-value on plans. To match energy design at minimum. • FOUNDATION REQUIREMENTS 13. Note anchor bolt spacing on plans. 14. No information provided for underfloor venting to existing raised floor area to be affected by proposed project. 15. Foundation anchorage in Seismic Design Categories C, Do, D1 and D2. In addition to the requirements of Section R403.1.6, the following requirements shall apply to wood light-frame structures in Seismic Design Categories Do, D1 and D2 and wood light-frame townhouses in Seismic Design Category C. R403.1.6.1 1. Plate washers conforming to Section R602.11.1, 0.229"x3"x3", shall be provided for all anchor bolts over the full length of required braced wall lines. Properly sized cut washer shall be permitted for anchor bolts in wall lines not containing braced wall panels. 2. The following locations shall require the use pressure-preservative treated wood (Section R317.1): a. All sill plates that rest on concrete or masonry exterior walls and are less than 8" above exposed ground. b. Sills and sleepers on a concrete or masonry slab that is in direct contact with the ground (unless separated from such slab by an impervious moisture barrier). • STRUCTURAL 16. Floor joists seem to be over spanned. See table 502.3.1 (1) for allowable joist spans. 17. Show stud size, height and spacing on the plans. Maximum allowable stud heights shall be per Table R602.3(5). 18. Detail and reference all shear locations with a detail showing shear extending to floor/roof sheathing. Detail to include edge nailing of roof diaphragm to members below. Minimum 2 details required i.e. when shear walls are perpendicular to roof framing/trusses (blocking panels) and when shear walls are parallel to roof framing members. 19. Not sure how design criteria shown on page 6 was utilized on this plan set. Are there structural calculations? please clarify. If necessary, please refer to California Building Code Chapter 16 for allowable residential design criteria. City of Carlsbad cbR2017-2957 Dec 21, 2017 20. Show strap ties at discontinuous top plates. 21. Please note floor sheathing type, span rating and nailing schedule on plans. 22. Reference section E-E where it may pertain on the plans. 23. Section D-D is referenced to interior wall. but details shown exterior conditions. 24. Provide and reference shear and wall connection detail at rafter mid-span support. 25. Is a header being added to new hall passage at rafter mid-span support. whether adding or using existing header at this location, please note header size and span on plans. 26. Detail braced wall connections, including roof and floor diaphragms, to braced walls. Section R602.10.8. 27. Although not critical for this project. A braced wall is noted for new wall between bedroom and hallway. Please note that foundation is needed to bracing wall panels. Also, this wall is not necessary to be a brace/shear wall as a new roof diaphragm is being constructed. 28. Provide and reference detail for new to existing roofing connection at load bearing location. 29. Plans show that an opening is to be provided at existing to new roof sheathing. Please note that this is not necessary, making a break on the roof sheathing will create a weak point on the diaphragm and the entire roof structure may fail under torsional forces. Please consider the assistance of a California licensed architect or engineer for further clarification on wood diaphragm load path. a) On the same note. Please show that sufficient attic ventilation will be provided for existing attic space. 30. Show rafters to be continued to exterior walls. See Page 5. Appears to be discontinued at upper left wall. 31. The plans shall indicate that special inspection will be provided for the following work. (CBC Chapter 17 and Section 107.2) a) Expansion/Epoxy anchors. Periodic special inspection should be provided for anchors installed in hardened concrete. Section 1705.3. City of Carlsbad cbR2017-2957 Dec 21, 2017 • MECHANICAL 32. Detail the dryer exhaust duct design from the dryer to the exterior. The maximum length is 14 feet with a maximum of two 90-degree elbows or provide the manufacturer's duct length specification description on the plans: Include the dryer specifications (manufacturer, model, and fuel type) as well as the duct description (size and type). CMC Section 504.4.2. • PLUMBING 33. Show water heater size (1st hour rating), type, and location on plans. Note: For both new dwellings and additions the Energy Standards (150.0(n)) requires a gas input rating of 200,000 Btu for both tank and instantaneous gas water heaters. (Also) Provide a gas piping design for the gas system. • ENERGY CONSERVATION 34. For plans submitted for plan check on or after 1/03/17, provide an energy design detailing compliance with the Mandatory Measures and either the Performance or Prescriptive Methods of compliance. The Prescriptive design and the latest Performance software programs are available at: http://www.energy.ca.gov/title24/2016standards/index. html 35. A complete energy plan check will be performed after completed and/or the corrected energy design has been provided. 36. Current energy code is 2016. 37. Include all applicable sections of the (MF1 R) RMS-1 form or the specifications contained thereon with the plans. Residential Energy Lighting Requirements: ES 150.0(k) 38. All installed luminaires shall be high-efficacy in accordance with ES TABLE 150.0-A. Light sources that are not marked "JAB-2016-E" shall not be installed in enclosed luminaires. ES 150.0(k) 39. In bathrooms, garages, laundry rooms, and utility rooms at least one luminaire shall be controlled by a vacancy sensor. 40. Dimmers or vacancy sensors shall control all LED style luminaires. Two exceptions: Fixtures installed in hallways or (closets under 70 square feet). 41. Recessed can light fixtures shall be IC listed, air-tight labeled, and not be equipped with a standard medium base screw shell lamp holder. ES 150.0(k) Residential ventilation requirements: ES 150.0(o)/ASHRAE 62.2 42. Alternations When replacing or modifying the mechanical system: City of Carlsbad cbR2017-2957 Dec 21, 2017 o If more than 40' of new ductwork is installed in unconditioned space, HERS inspection is required for both existing and new duct sealing. o Replacement of mechanical equipment (air handler, condensing unit of an air conditioner or heat pump, cooling or heating coil, or the furnace heat exchanger) requires HERS inspection. o Note: The CF1 R-AL T-HVAC form may be submitted at the final inspection, it is not required at initial plan submittal. • MISCELLANEOUS 43. If CalGreen requires a Waste Management Plan, the applicant shall submit the Carlsbad special form found at end of list. 44. If special inspection is required, the designer shall complete the city's "Special Inspection Agreement" found at the end of this list. 45. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 46. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes D No D 47. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Rich Moreno at EsGil Corporation. Thank you. City of Carlsbad cbR2017-2957 Dec 21, 2017 /f~ ~t < ·~ CI TY OF CARLSBAD SPECIAL INSPECTION AGREEMENT B-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.car1sbadca.gov In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed requires special inspection, structural observation and construction material testing. 'roject/Permit: _____________ Project Address: _________________ _ A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder 0. (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please print) ____________ .. (First) (Ml) (Last) Mailing Addres''"------ Email_-_________________________ Phone: __________ _ I am: DProperty Owner OProperty Owner's Agent of Record DArchitect of Record DEngineer of Record State of California Registration NumbeL· _____________ Expiration Date: ________ _ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. Signatur~------------Date: ____________ _ B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder I owner-builder Contractor's Company Name.: ____________________ Please check if you are OWner-Builder ti Name: (Please print) ___________________________________ _ (First) (Ml l (Last] Mailing Address ___________________________________ _ Email: _________________________ Phone: ___________ _ State of California Contractor's License Number: ___________ Expiration Date: _______ _ • I acknowledge and, arn aware, of special requirements contained in the statement of special inspections noted on the approved plans; • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. • I will provide a final report I letter in compliance with CBC Section 1704.1.2 prior to requesting final inspection. Signature-________________________ ,Date: ___________ _ B-45 Page 1 of 1 Rev. 08/11 City of Carlsbad cbR2017-2957 Dec 21, 2017 [DO NOT PAY -THIS IS NOT AN INVOICE} VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK#.: cbR2017-2957 PREPARED BY: Rich Moreno BUILDING ADDRESS: 1391 Oak Ave. BUILDING OCCUPANCY: R-3/U BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Addition 132 169.50 Remodel 40 46.51 Reroofing 288 175.66 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance -~\a"._':_~eck Fee ~~_rdi~_ance __ : ~ Type of Review: D Repetitive Fee -... 1 Repeats -~---_J Comments: 0 Complete Review D Other D Hourly EsGil Fee DATE: Dec 21, 2017 Reg. VALUE ($) Mod. 22,374 1,860 50,590 74,824 $511.851 $332.70/ D Structural Only 1------11 Hr. @ • $291.751 Sheet 1 of 1 STORM WATER POLLUTION PREVENTION NOTES 1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN IS EMINENT. 2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING RAINFALL. 3. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT ( 40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM AGGREGATE. 6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. 7. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY REGULATIONS. OWNER'S CERTIFICATE: I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTIENT PRACTICABLE TO AVOID THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO AVOID THE EXPOSURE OF STORM WATIER TO CONSTRUCTION RELATIED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETIE AND APPROVED BY THE CITY OF CARLSBAD. 0Jtt5}7~\W1(1\'s ~~N1 'iU'Jf1tiif tm OWNER(S)/OWNER'S AGENT NAME (SIGNATURE) E-29 STORM WATER COMPLIANCE FORM TIER 1 CONSTRUCTION SWPPP BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE Erosion Control Sediment Control BMPs Tracking Non-Slonn Water Waste Management and Materials BMPs Control BMPs Management BMPs Pollution Control BMPs C: -C: C: 0 -.Q .Q :;, C: C: -0 --"' 0 Q) -0 Q) -0 "' C: " " C: C: "' E C: E C: -0 -:, :, .Q 'o ·.: .9-0 0 0 E Q) L L -L "' ::; ,, "' "' L --·E '-:, >-"' C: "' a. L C: -~ :S "'"' "' la er L 0 C: "' 015 "' ·a. C: "' C: L "' L w ~ C: 0 Best Management Practice* ~ .E "' 0 a, L 0 Q) 0 "' Q) "' 0 :;, -.c "' ., t-'= "' 0 C: UL u "' --0 ~ "' ::; C: Q) C: (BMP) Description 7 "' " "'VJ .!: "' E "' "' "' "' a, "0 C "' C: -0 "' ~ C: Cl :::, "' -"' "' :3 ~ Q) e -0 '5 0 ., C: L Q ~~ -0 >-0"' C: C: 0 > 1l E ~ " C: Cl a, VJ·-"' Cl:.:;; U<i> Oo "' "' Q) ::; Cl "' Cl C: " er E 0 ~~ i!l 0 " O'):;; " ~.£ :g g c =a. L-3 "' X "' a. e "' 0 u.. E .,,_ al -:, .a E ~ = it L•-C: 0 :c " C: ·.: .,,_ "' --0 .c C: "' " L > "' :, -0 L-·-Q) ·--0 ~t, ·s: ~ 0 <i> L "' " ---0 0 0 0 -·-a. 'o "' "' " " C: _a L .a 0 -·-0 -o -~8 ·-C: L 0 -0 0 0 0 "' .B 0 00 .c "' 0 Q) 0 0 L 0 in Q) .c .a L .::, 0 0 -L en ..s :i:ct J:8" 0 ~u o-0 -oo "' 3 we:, vi VJ u G:: "' VJ> VJ VJ a. VJ(>'. a. ::; VJ ::; VJ VJU VJ::; CASQA Desig,ation 7 r--co .... co 0 "' "' .... co i "' "' .... "' "' i i "' "' to .... i I I I I I I I I I I I I I I I I I I I u u u u w w w w w w w w l!c l!c VJ VJ VJ VJ i i i i i Construction Actvity w w w w VJ VJ VJ VJ VJ VJ VJ VJ z z z z GrodinntSoil Disturbance Trenchina/Excavation "' Stockoilina • Drillinn /Barino Concrete/ Asohalt Sawcuttina Concrete Flatwork Pavinq Conduit/Pioe Installation Stucco/Mortar Work Waste Disoosal Staqina/Lay Down Area Eauioment Maintenance and Fuelina Hazardous Substance Use/Starace Dewaterina Site Access Across Dirt Other (listl: Instructions: 1. Check the box to the left of all applicable construction activity (first column) expected to occur during construction. 2. Located along the top of the BMP Table is a list of BMP's with it's corresponding California Stormwater Quality Association (CASQA) designation number. Choose one or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column. 3. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project. PROJECT INFORMATION Site Address: I 30 I O 4 1L-: Av 1' Assessor's Parcel Number: ;;lo$-011:0 · I 8'.-00 Emergency Contact: Name: ~"'"'".")I"' H.,..fs,~a.., 24 Hour Phone: 3:CeO ·-45}3-31,,>-'1 Construction Threat to Storm Water Quality (Check Box) 0 MEDIUM ilJ LOW "' -"' 0 ..,_ C: "' Q) :, E 0"' ~ "' O 0 N C: O 0 :,: ::; to I i "' -"' o-3 C: "' "'E -., ~ "' " 0 C: C: 0 0 u ::; co I i Page 1 of 1 REV 11/17