HomeMy WebLinkAbout1410 BUENA VISTA WAY; ; CB033466; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Building Inspection Request Line (760) 602-2725
02-22*2004 Residential Permit Permit No: CB033466
Job Address: Permit Type: Parcel No:
Valuation:
Occupancy Group: # Dwelling Units: Bedrooms:
Project Title:
1410 BUENA VISTA WY CBAD RESDNTL SubType: 2DU
1561201500 Lot #: 0
$63,491 .OO Construction Type: NEW
1 Structure Type: MF2-4
1 Bathrooms: 1
CARPORT & 244 SF COVERED PORCH
Reference #:
BRUBAKER RES-640 SF2DU, 410 SF
Applicant:
WORTHING INC, B. A. SUITE #201
690 CARLSBAD VILLAGE DR
CARLSBAD, CA 92008
61 9-729-3965
Status: ISSUED Applied: 1211 512003
Plan Approved: 02/27/2004
Issued: 02/27/2004
Entered By: KMT
Inspect Area:
Orig PC#:
Plan Check#:
Owner: BRUBAKER JAMES L&LESLIE A
1410 BUENA VISTA WAY
CARLSBAD CA 92008
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee Other Bridge Fee BTD #2 Fee
BTD #3 Fee
Renewal Fee Add'l Renewal Fee Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'l Pot. Water Con. Fee Recl. Water Con. Fee
$407.96
$0.00
$265.1 7
$0.00 $0.00 $6.35
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00 $0.00
$0.00
$0.00
$0.00 $0.00
Meter Size
Add'l Recl. Water Con. Fee
Meter Fee
SDCWA Fee CFD Payoff Fee PFF PFF (CFD Fund)
License Tax
License Tax (CFD Fund)
Traffic Impact Fee Traffic Impact (CFD Fund) Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL MECHANICAL TOTAL
Housing Impact Fee
Housing InLieu Fee
Housing Credit Fee
Master Drainage Fee Sewer Fee Additional Fees TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00 $0.00
$0.00
$276.36
$31 1.64 $0.00
$91 .oo
$35.00
$21.50 $2,925.00
$0.00
$0.00
$0.00
$927.00
$0.00 $5,266.98
Total Fees: $5,266.98 Total Payments To Date: $265.17 Balance Due: $5,001.81
5258 02/27\04 0002 01 02
CGP 5001 81
PERM IT APPLl CAT1 0 N
ClrY OF CARLSBAD BUILDING DEPARTMENT
-1635 Faraday Ave., Carlsbad, CA 92008
5. CONTRACTOR - COMPANY NAME
(Sec 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001)
Name
State License # 3 46 7 CP 4
Designer Name
Z~C. P.o.Hox 1041 a. . CA 41 6 15 @A NwKntl, f-1~4 -I a~i r 34~3 Address city Statelzip Telephone #
License Class f3 -I City Business License # 5 4 4 360 .. 04! Cwls bmA P-A-. q2O\R lib 01 2rq - 34c95
Address city Statelzip Teleph'one
Araokj Wnf&v\a PO $ox I
FOR OFFICE USE ONLY
PLAN CHECK NO. @033ybb
EST. VAL. [13~~p9/, a
Plan Ck. Deposit/
Validated By
ab5 e r7
6. WORKERS' COMPENSATlOd
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of th work for which this permit is issued
dl have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued
Insurance Company
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$lo01 OR LESS)
0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
My worker's compensation insurance carrier and policy number are:
Policy No. 000~1 1s - 2003 Expiration Date - I - 04
compensation, damages as provided for in Section 3706 of the code, . terest and attorney's fees.
SIGNATURE DATE I 19/03
7. OWNER-BUiLDER
License Law for the following reason:
th wages as their sole compensation, will do the work and the structure IS not intended or offered for sale
ractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code, The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0
1.
2.
3.
4
number I contractors license number):
5.
of work):
PROPERTY OWNER SIGNATURE DATE
COMPLETE THIS SECTION FOR NONdESlDENTlAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous m
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site' 0 YES 0 NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
8. CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
9. APPLICANT CERTIFICATION
I certify that I have read the application and state that the above information is correct and that the information on the plans IS accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is
APPLICANT'S SIGNATURE
I am exempt under Section
I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES
I (have I have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number)
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type
Business and Professions Code for this reason'
UNO
ials registration form or risk management and prevention
0 YES 0 NO
180 days (Section 106 4 4 Uniform Building Code)
DATE '2 1 I G/ 103
WHITE: File YELLOW: Applicant PINK: Finance
City of Carlsbad Bldg Inspection Request
For: 07/26/2004
Permit# CB033466 Inspector Assignment: PD
Title: BRUBAKER RES-640 SF2DU, 41 0 SF
Description: CARPORT & 244 SF COVERED PORCH
Type: RESDNTL SubType: 2DU
Job Address:
Suite:
Location:
APPLICANT
Owner:
Remarks:
Total Time:
1410 BUENA VISTA WY
Lot 0
WORTHING INC, B. A.
BRUBAKER JAMES L&LESLIE A
FOR OCCUPANCY-NOT FINAL
CD
19
29
Description
Final Structural
Final Plumbing
Phone: 7607293965
Inspect &L r:
Requested By: TERESA
Entered By: ROBIN
Act Comment
t 39 Final Electrical
& 49 Final Mechanical
Associated PCRs/CVs
Inspection Histow
Date Description
06/16/2004 21 UndergroundlUnder Floor
0611 612004 23 GasTTesVRepairs
06/03/2004 17 Interior LathIDrywall
05/27/2004 17 Interior Lath/Drywall
05/25/2004 16 Insulation
05/19/2004 84 Rough Combo
05/17/2004 84 Rough Combo
05/06/2004 13 Shear PaneWHD's
04/23/2004 15 RoofIReroof
04/23/2004 15 RoofIReroof
04/22/2004 15 RooWReroof
03/22/2004 21 UndergroundIUnder Floor
03/09/2004 21 UndergroundIUnder Floor
Act lnsp Comments
AP JM 2 DU TO SEWER TIE IN
AP JM 2DU&POOLEQUlP
AP PD
AP PD
AP PD
AP PD
CO PD ONCARD
AP PD
PA PY NEED REVISED PLANS
PA PY OK TO COVER
CO PD NOLADDER
AP PD RELOCATED
AP PD
City of Carlsbad Bldg
For: 04/23/2004
Permit# CEO33466
Title: BRUBAKER RES-640 SFSDU, 410 SF
Description: CARPORT & 244 SF COVERED PORCH
Type: RESDNTL SubType: 2DU
Job Address: 1410 BUENA VISTA WY
Suite: Lot 0
Location:
APPLICANT WORTHING INC, B. A.
Owner: BRUBAKER JAMES L&LESLIE A
Remarks:
Total Time:
Inspection Request
Inspector Assignment: PD
Phone: 7607293965
Requested By: TERESA
Entered By: CHRISTINE
CD Description Act Comment
- Associated PCRs/CVs
Inspection History
Date Description Act lnsp Comments
03/22/2004 21 Underground/Under Floor AP PD RELOCATED
03/09/2004 21 UndergroundlUnder Floor AP PD
* c, NOTICE ' 6- -*
CITY O$ CARLSBAD (760) 602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE
PERMIT NO. 0'3 c /
4
02-2725. RE-INSPECTION FEE DUE? YES
PHONE
@ CODE ENFORCEMENT OFFICER
EsGil Corporation
In Partnership with Government for Building Safety
DATE: January 15,2004
JURISDICTION: Carlsbad
PLAN CHECK NO.: 03-3466 SET: I1
PROJECT ADDRESS: 1410 Buena Vista Way
PROJECT NAME: Brubaker 2nd Dwelling, Carport and Porch
0
w
0
0
0
IXI
0
IXI
0 FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction’s building codes.
The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant’s copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: 1
REMARKS: Designer to show drag
Mail Telephone Fax In Person
page 3 (Highlighted)
By: Bill Elizarraras Enclosures:
Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 1/8/04 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 4 Fax (858) 560-1576
EsGil Corporation
In Partnersdip w’td Government for Buifding Safety
DATE: December 29, 2003
JURI SD I CTl ON : Carlsbad
PLAN CHECK NO.: 03-3466
0 APPLJCANT
0 PLAN REVIEWER
c1 FILE
SET: I
PROJECT ADDRESS: 1410 Buena Vista Way
PROJECT NAME: Brubaker 2nd Dwelling , Carport and Porch
0
0
w
0
w
O w
0
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction’s building codes.
The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant’s copy of the check list has been sent to:
BA Worthing Inc.
P.O. Box 1041, Carlsbad, CA. 9201 8
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Brooks Worthing
Date contacted: ,E/tq/o3 (by:*?)
REMARKS:
MaiL Telephone Fax-‘ In Person
By: Bill Elizarraras Enclosures:
E sg il Corporation 0 GA 0 MB EJ 0 PC 12/16/03
Telephone #: 760-729-3965
Fax #: 760-729-0789
trnsmtl.dot
9320 Chesapeake Drive, Suite 208 San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
Carlsbad 03-3466
December 29,2003
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 03-3466 JURISDICTION: Carlsbad
PROJECT ADDRESS: 1410 Buena Vista Way
FLOOR AREA: 640 sq.ft. 2nd Dwelling - STORIES: 1
410 sq.ft. Carport
244 sq.ft. Porch HEIGHT: 14'
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: ESGIL CORPORATION: 12/16/03
DATE PLANS RECEIVED BY
DATE INITIAL PLAN REVIEW PLAN REVIEWER: Bill Elizarraras
COMPLETED: December 29,2003
FOREWORD (PLEASE READ):
This pian review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments. Clearance from those departments may be required prior to
the issuance of a building permit.
Present California law mandates that residential construction comply with the 2001 edition of
the California Building Code (Title 24), which adopts the following model codes: 1997 UBC,
2000 UPC, 2000 UMC and 1999 NEC (all effective 11/1/02).
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, Le., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad 03-3466
December 29,2003
PLANS
1. Please make all corrections on the original tracings, as requested in the correction
list. Submit two sets of plans for residential projects. For expeditious processing,
corrected sets can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
2. Show locations of permanently wired smoke detectors with battery backup:
a) Inside each bedroom.
b) Centrally located in corridor or area giving access to sleeping rooms.
3. Provide truss details and truss calculations for this project (Three point bearing
Scissor truss was not included with this submittal) . Specify truss identification
numbers on the plans.
4. Detail interior shear transfer connections, including roof diaphragms, to shear
walls. Section 231 5.
5. Specify on the plans the following information for the fireplace(s), per Section
106.3.3:
a) Manufacturer’s name.
b) Model name/number.
c)
d)
e)
IC60 approval number, or equal.
Show height of chimney above roof per I.C.B.O. approval or UBC Table
Note on the plans that approved spark arrestors shall be installed on all
chimneys. UBC, Section 31 02.3.8.
31-B.
6. Show the location, type and size (BTU’s) of all heating and cooling appliances or
systems.
7. Show water heater size (ISt hour rating), type, and location on plans. UPC,
Section 501 .O.
8. Show T and P valve on water heater and show route of discharge line to exterior.
UPC, Section 608.5.
, Carlsbad 03-3466
December 29, 2003
9. In Seismic Zones 3 and 4, show that water heater is adequately braced to resist
seismic forces. Provide two straps (one strap at top 1/3 of the tank and one strap
at bottom 1/3 of the tank). UPC, Section 510.5
IO. Note on the plans: “The manufactured windows shall have a label attached
certified by the National Fenestration Rating Council (NFRC) and showing
compliance with the energy calculations.”
11. Provide drag strap @ Porch beam to top plates.
To speed up the review process, note on this list (or a copy) where each correction item
has been addressed, i.e., pian sheet, note or detail number, calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a result
of corrections from this list. If there are other changes, please briefly describe them
and where they are located in the plans.
0 Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes 0 No 0
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding these plan
review items, please contact Bill Elizarraras at Esgil Corporation. Thank you.
Carlsbad 03-3466
December 29,2003
VALUATION AND PLAN CHECK FEE
J U RI S DI CTI ON : Carlsbad PLAN CHECK NO.: 03-3466
PREPARED BY: Bill Elizarraras
BUILDING ADDRESS: 1410 Buena Vista Way
DATE: December 29,2003
BUILDING OCCUPANCY: R3/U1 TYPE OF CONSTRUCTION: VN
___
Bldg. Permit Fee by Ordinance
____
Plan Check Fee bv Ordinance v
Type of Review: Complete Review Structural Only
u Repetitive Fee ---;I Repeats
Other
Hourly 11 Hour *
Esgil Plan Review Fee 0
I $259.32 I
$223.421
Comments:
Sheet 1 of 1
rnacvalue.doc
BUILDING PLANCHECK CHECKLIST
PLANCHECK NO.: CB c:-3 I 3 YL6 y/fQt 3%u;i,< 1’ -? BUILDING AD RE S: )I c’> bz, i U,J/
ASSESSOR’S PARCEL NUMBER: I% n w EST. VALUE: LT yy/
DATE: (.$--Yi/d? ~
PROJECT DESCRIPTION: ,y / &‘A {\ 1 &I> I **- j^, t
J 4
/
ENGINEERING DEPARTMENT
APPROVAL DENIAL
The item you have submitted for review has been approved. The approval is based on plans,
information andlor specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply
with instructions in this report can result in
report of deficiencies
sary corrections to plans
or compliance with applicable
ds. Submit corrected plans and/or
specifications to this office for review.
suspension of permit to build.
A Right-of-way permit is required prior to
construction of the following improvements:
N~E: JOANNE JUCHNIEWICZ
City of Carlsbad Dedication Checklist
Improvement Application Address: 1635 Faraday Avenue, Carlsbad, CA 92008
Improvement Checklist
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
Phone: (760) 602-2775
CFD INFORMATION
Parcel MaD No:
Lots:
Recordation:
Carlsbad Tract:
Right-of-way Permit Application
Right-of-way Permit Submittal Checklist
and Information Sheet
Sewer Fee Information Sheet A4
I Rev. 7/1uM)
BUILDING PLANCHECK CHECKLIST
SITE PLAN
1. Provide a fully dimensioned site plan drawn to scale. Show: KKV A. NorthArrow F, Right-of-way Width & Adjacent Streets
B. Existing & Proposed Structures C$?s Driveway widths
Existing Street Improvements
Property Lines
& Existing or proposed sewer lateral
Existing or proposed water service
E. psements J. Existing or proposed irrigation service
2. Show on site plan:
A. Drainage Patterns
1. Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course.
2. ADD THE FOLLOWING NOTE: “Finish grade will provide a minimum positive
drainage of 2% to swale 5’ away from building.”
Existing & Proposed Slopes and Topography
(s) that serves the project. Each unit requires a separate service, however,
Size, type, location, alignment of existing or proposed sewer and water service
second dwelling units and apartment complexes are an exception. =
1 D. ‘ Sewer and water laterals should not be located within proposed driveways, per u standards. ”;s 1 ,.,~L ti<c,t-.--\e -2 /%LL/Lde-- ;h
0 3. Include on title sheet: e, p&i i ,\ LL4-C-L‘
A. Site address
9. Assessor’s Parcel Number
C. Legal Description
For commercial/industriaI buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc.) previously approved.
EXISTING PERMIT NUMBER DES C R I PTI 0 N
2 Rev. 7/14/00
BUILDING PLANCHECK CHECKLIST
1ST 2ND
nu
00
3*
0
0
DISCRETIONARY APPROVAL COMPLIANCE
4a. Project does not comply with the following Engineering Conditions of approval for
Project No.
4b. All conditions are in compliance. Date:
DEDICATION REQUIREMENTS
5. Dedication for all street Rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $15,000, pursuant to Carlsbad
Municipal Code Section 18.40.030.
Dedication required as follows:
Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 1/2" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax.
Dedication completed by: Date:
IMPROVEMENT REQUIREMENTS
6a. All needed public improvements upon and adjacent to the building site must be constructed at time of buildina construction whenever the value of the construction exceeds $75.000, pursuant to Carlsbad Municipal Code Section 18.40.040.
Public improvements required as follows:
Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the
3 H:\WORD\DOCSCHKLSTfflirg Plnchffk Cat Form (RIDDLE. HARVEY 7-12-00).doc Rev. 1m98
*.- -----. BDkWWPLANGHECK CJA.EW
checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit.
Improvement Plans signed by: Date:
b. Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or
current grant deed on the property and processing fee of $310 so we may
prepare the necessary Future Improvement Agreement. This agreement must be e of a Building permit.
(*%A- Z,>d% - LW/
- cp t
0 6c. Enclosed please find your Future Improvement Agreement. Please return
agreement signed and notarized to the Engineering Department.
Future Improvement Agreement completed by:
Date:
0 0 6d. No Public Improvements required. SPECIAL NOTE: Damaaed or defective
improvements found adiacent to buildinq site must be reDaired to the satisfaction
of the Citv Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
conditions that invoke the need for a grading permit are found in Section
11.06.030 of the Municipal Code.
7a. Inadequate information available on Site Plan to make a determination on grading
76. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached. NOTE: The Gradina Permit must be issued and rough qrading
approval obtained prior to issuance of a Buildinq Permit.
xx,/ requirements. Include accurate grading quantities (cut, fill import, export).
0 0 0
Grading Inspector sign off by: Date:
0 0 7c. Graded Pad Certification required. (Note: Pad certification may be required even
if a grading permit is not required.)
ti \WORD\DOCS\CHKLST\BU,~inp Planchsck CUsl Form (Generic 7-14-W) doc 4 Re" 71141W
BUILDING PLANCHECK CHECKLIST
1ST 2ND
7d .No Grading Permit required.
0 0 0 7e. If grading is not required, write “No Grading’’ on plot plan.
@y 0 0 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-way and/or
private work adjacent to the public Right-of-way. Types of work include, but are
not limited to: street improvements, tree trimming, driveway construction, tying
into public storm drain, sewer and water utilities.
MISCELLANEOUS PERMITS
Right-of-way permit required for:
p)y‘ 0 0 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153,
for assistance.
Industrial Waste permit accepted by:
Date:
@ 0 0 10.NPDESPERMlT
Complies with the City’s requirements of the National Pollutant Discharge
Elimination System (NPDES) permit. The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas. Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
OccurY d 0 0 11. LhRequiredfeesareattached
Q No fees required
WATER METER REVIEW
12a. Domestic (potable) Use
Ensure that the meter proposed by the owner/developer is not oversized.
Oversized meters are inaccurate during low-flow conditions. If it is oversized, for
the life of the meter, the City will not accurately bill the owner for the water used.
All single family dwelling units received “standard” 1” service with 5/8” service.
00
5 Rev. 7/44/00
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3RD
0 0 12b. Irrigation Use (where recycled water is not available)
All irrigation meters must be sized via irrigation calculations (in gpm) prior
to approval. The developer must provide these calculations. Please follow
these guidelines:
0 If owner/developer proposes a size other than the “standard”, then
owner/developer must provide potable water demand calculations,
which include total fixture counts and maximum water demand in gallons
per minute (gpm). A typical fixture count and water demand worksheet is
attached. Once the gprn is provided, check against the “meter sizing
schedule’’ to verify the anticipated meter size for the unit.
0 Maximum service and meter size is a 2” service with a 2” meter.
0 If a developer is proposing a meter greater than Z”, suggest the
installation of multiple 2” services as needed to provide the anticipated
demand. (manifolds are considered on case by case basis to limit
multiple trenching into the street).
1. If the project is a newer development (newer than 1998), check the recent
improvement plans and observe if the new irrigation service is reflected on
the improvement sheets. If so, at the water meter station, the demand in
gpm may be listed there. Irrigation services are listed with a circled “I”,
and potable water is typically a circled “W. The irrigation service should
look like:
STA 1+00 Install 2” service and
1.5: meter (estimated I00 gpm)
2. If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case
irrigation demand (largest zone with the farthest reach). Typically, Larry
Black has already reviewed this if landscape plans have been prepared,
but the applicant must provide the calculations to you for your use. Once
you have received a good example of irrigation calculations, keep a set for
your reference. In general the calculations will include:
0 Hydraulic grade line
0 Elevation at point of connection (POC)
0 Pressure at POC in pounds per square inch (PSI)
0 Worse case zone (largest, farthest away from valve
0 Total Sprinkler heads listed (with gpm use per head)
0 Include a 10% residual pressure at point of connection
3. In general, all major sloped areas of a subdivision/project are to be
irrigated via separate irrigation meters (unless the project is only SFD with
no HOA). As long as the project is located within the City recycled water
Rev. 7/1m 6 H:\WORD\WCSCHKLSnBU!q Phcheck CM Form (Ganerlc).doc
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3RD
service boundary, the City intends on switching these irrigation
services/meters to a new recycled water line in the future. py 0 0 12c. Irrigation Use (where recycled water is available)
1. Recycled water meters are sized the same as the irrigation meter above.
2. If a project fronts a street with recycled water, then they should be
connecting to this line to irrigate slopes within the development. For
subdivisions, this should have been identified, and implemented on the
improvement plans. Installing recycled water meters is a benefit for the
applicant since they are exempt from paying the San Diego County Water
Capacity fees. However, if they front a street which the recycled water is
there, but is not live (sometimes they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego
Water Capacity Charge. If within three years, the recycled water fine is
charged with recycled water by CMWD, then the applicant can apply for a
refund to the San Diego County Water Authority (SDCWA) for a refund.
However, let the applicant know that we cannot guarantee the refund, and
they must deal with the SDCWA for this.
0 0 0 13. Additional Comments:
7 Rev. 7ll4iW
ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
&mate based on unconfirmed information from applicant.
Calculation based on building plancheck plan submittal. ly( v
Address:
Prepared by: Date: (/2 ?/b L/ ' Checked by: Date:
EDU CALCULATIONS: List types and square footages for all uses.
Types of Use: .i> Sq. Ft./Units: EDU's: 1
Types of Use: Sq. Ft./Units: EDU's:
ADT CALCULATIONS: List types and square footages for all uses.
c) '\fi%'%i 1 'L?lrzi 19' Bldg. Permit No.
~ypesofuse: sf? LJ Sq. Ft./Units: ADT's: I
Types of Use: Sq. Ft./Units: ADT's:
FEES REQUIRED:
WITHIN CFD: 0 YES (no bridge & thoroughfare fee in District #I, reduced Traffic Impact Fee) d
PARK AREA & #: k&*RK-iN-LiEu FEE k/
FEE/UNIT: X
2. TRAFFIC IMPACT FEE
ADT'dUNITS: I
Aci LIT1 Es MANAGEMENT FEE
/
bkRiDGE AND THOROUGHFARE FEE
ADT's/UNITS:
UNIT/SQ.FT.:
EDU's: 1 5. SEWER FEE
BjcLt#f AREA:
EDU's:
NO. UNITS: =$ ,v;
X FEE/ADT: 57$?
(DIST. #1 DIST. #2 DIST. #3 )
X FEE/ADT: =$ {f
ZONE:
X FEE/SQ.FT./UN IT:
X FEE/EDU: c23 /
X FEE/EDU: =$ ,&
=$ p . SEWER LATERAL ($2,500)
7. DRAINAGE FEES PLDA HIGH /LOW
ACRES: X FEEIAC:
&
8. POTABLE WATER FEES
UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION
F:\FEE CALCULATION WORKSHEET.doc
1 of2
Rev. 7/14/00
ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
0 9. RECLAIMED WATER FEES
UNITS CODE CONNECTION FEE METER FEE
--
TOTAL OF ABOVE FEES*: $
SNOTE: This calculation sheet is NOT a complete list of all fees which may be due.
Dedications and Improvements may also be required with Building Permits.
F:\FEE CALCULATION WORKSHEET.doc
2of2
Rev. 7/14/00
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CB &- a%&
Planner Rebeca Vazquez Phone (760) 602-4625
Address )qm t!%/fJ?& L’i&k L,CcL 9
APN: /3&*- /S&d -/*--(a L.. . I DU/AC \\ Type of Project & Use: 0~4 ,‘ Cc^.r,&. 1, Project Density: ’
Zoning:K/ General Plan; Facilities Management Zone: / ’
CFD (idout) #-Date of participation: Remaining net dev acres:
(For non-residential development: Type of land used created by this
permit: ) Circle One
Leqend: Item Complete Item Incomplete - Needs your action
Environmental Review Required: YES NO ,y‘ TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
0 0 Discretionary Action Required: YES NO> TYPE
APPROVAURESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
Coastal Zone AssessrnentEompliance
Project site located in Coastal Zone? YES- NO&
CA Coastal Commission Authority? YES- NO-
If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (61 9) 767-2370
Determine status (Coastal Permit Required or Exempt):
If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log #:
Coastal Permit Determination Form already completed? YES NO-
Follow-Up Actions:
1)
2)
lnclusionary Housing Fee required: YES NO -
(Effective date of lnclusionary Housing Ordinance - May 21, 1993.)
Data Entry Completed? YES ,x NO __
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATE!)
Stamp Building Plans as “Exempt” or “Coastal Permit Required (at minimum Floor Plans).
Complete Coastal Permit Determination Log as needed.
H:\ADMIN\COUNTER\EldgPlnchkRevChklst Rev 9/01
Site Plan:
1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines,
easements, existing and proposed structures, streets, existing street improvements, right-of-way
width, dimensional setbacks and existing topographical lines (including all side and rear yard
slopes).
2. Provide legal description of property and assessor’s parcel number.
Policy 44 - Neighborhood Architectural Design Guidelines
1. Applicability: YES NOL
2. Project complies YES NO
Zoning:
1.
2.
3.
4.
\, 5. \
Setbacks:
Front: Required 2c>’
Street Side: Required
Rear: Required ,-a
Top of slope: Required Shown
Interior Side: Required 0‘ Shown Shown 20’
Accessory structure setbacks:
Front: Required b‘
Interior Side: Required
Street Side: Required Shown
Rear: Required 3c >’ Shown
Structure separation: Required \ 0’ Shown
Shown a)‘
ij Shown \o’
Lot Coverage: Required Shown _.
\L\ ‘ Height: Required \q‘ Shown
Parking: Spaces Required .z Shown 2
(breakdown by uses for commercial and industrial projects required)
/ OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER yr?+w DATE 1 -ah-o i
H:\ADMIN\COUNTER\SldgPlnct-K RevChklst Rev 9101
CITY OF CARLSBAD - AFFIDAVIT OF COhlPLIANCE
FOR A SECOND DWELLIKG UKIT
Instructions to Property Owner (Affiant):
Please type or print complete and accurate answers in all blank spaces in Section I.
carefully, particularly Section 11.
understand and agree with the conditions of compliance.
Please read
Please read, sign and date Section 111 indicating that you
SECTION I - INFORMATION
Property owner(s):
Property Address:
Assessor Parcel No.
Subdivision:
Project Number:
1410
,’ State Zip Code
I or
Name Lot/Block Parcel No.
SECTION I1 - CONDITIONS FOR COMPLIANCE
PLEASE READ CAREFULLY
1. A second dwelling unit is an attached or detached dwelling unit which is located on the same lot as
In -._ PYICt,JIc .I_I __ r..-”le--A.- . .L, -, v~cup’IycI v,-;pcl sLllg,:u :--~o-c---::. I~~~~~~~ uLtdied J~&-,-- dweiiing unit and is: ..
a. Suitable for use as a complete living facility with provisions within the facility for
cooking, eating, sanitation and sleeping;
b. Occupied by one or more persons; and
C. Subordinate to the main dwelling unit.
2. The Property Owner(s) listed above hereby certifies that he/she owns the above referenced
property, as of the date of this affidavit, and to hisher belief and knowledge, there are no
conditions, covenants or restrictions on the property prohibiting a second dwelling unit apartment.
3. The Property Owner(s) agrees to the following terms and conditions:
FRM0006 6/03 PAGE 1 OF 2
a. The property and residence referenced above must not contain a second residential
dwelling unit unless it is in compliance with the second dwelling unit provisions of the
Zoning Ordinance of the City of Carlsbad.
b. The Property Owner(s) shall reside in either the main dwelling unit or second dwelling
unit described above, now, and for the life of this agreement, unless a lessee leases both
the main dwelling unit and the second dwelling unit.
C. The Second Dwelling Unit may only be rented and shall not be sold separately from the
main dwelling unit, unless the lot on which such units are located is subdivided.
d. The Property Owner(s) agree to rent the Second Dwelling Unit at a monthly rental rate
which shall not exceed an amount equal to 30% of the gross monthly income of a low-
income household, adjusted for household size, at 80% of the San Diego County median
income.
e. A copy of this agreement and Affidavit must be given by the Property Owner(s) to
prospective purchasers of the property prior to entering into a sales contract for said
prapertjj.
SECTION I11 - AFFIRMATION AND AGREEMENT
I HEREBY DECLARE AND AFFIRM, under penalty of perjury, that all matters and facts set forth in this
agreement are true and correct to the best of my knowledge, information and belief, and that I (we)
understand, accept and will abide by the regulations, requirements, and standards governing the Second
Dwelling Unit.
FRM0006 6/03 PAGE 2 OF 2
f 9'-9 1/2" .r BRUBAKER 5/12 2.5/12 PITCH
1410 BUENA VISTA WAY
CAALSBAD COMPOSITION ROOF
f STRUCTURAL TRUSS INC ASSUMES NO x
RESPONSIBILITY FOR TRUSSES CUT
OR INSTALLED IMPROPERLY.
X BACKCHARGES ARE NOT ACCEPTED
TYPE QTY Descriptior
2nd DWELLING 2x4 TOP CHORD
24" OVERHANG
REGULAR END BLOCK
x
I I (1 * IBT 6 1520176 BTD 1 1520176
BTE 1 1520177
BTF 1 1520176
BTG 1 1520176
BTS 14 1520178
CGE 1 GABLE END
2 1520175
CERT IF IEO INSPECTION
IN STRICT ACCORDANCE
WITH UBC 2321.3
PREFABR I CATED
-1
34ii
,
- @ 8racing bo top and bottom chards not required, provided
m CompuTrus, Inc
Murw * Ccrmputer Syzocmr
WARNINGS:
1. Read all General Notes and Warnings before construction of trusses.
2. Builder and erection contradw should be advised of all General Notes and Warnings before
canstructian commences,
3. 1x3 cornpression we4 bracing must be installed Mere shown +.
4. All lateral force resisting elements such ats temporary and permanent bracing. must be
designed and provided by designer of c0mpIete sbucture. CompuTrus assumes no responsibil-
rty forsuch badng.
5. No laad should be appkd to any compomnt until after all bracing and fasteners are complete.
and at no time should any loads greater than design loads be applied to any component
6. CornpuTrus has no control over and assumes no responsibility for the fabrication. handling.
shipment and installation of components.
7. This design is furnished subject to me limitations on truss designs set forth by the Truss Plate
Institute in 'Bracing wood Trusses. HIB-91'. a copy of which will be furnished by CornpuTrus
upon request.
GENERAL NOTES, unless otheNvise noted:
1. Design to support loads as shown.
respectively.
3. 2x4 Impact bridging or lateral bracing required where shown + +.
4. Installation of truss is the responsibility of the respective contractor.
5. Design assumes trusses are to be used in a noncorrosive environment and are for "dry
condition' of use. &
6. Design assumes full bearing at all supports shown. Shim or wedge if necessary.
7. Design assumes adequate drainage is provided.
8. Plates shail be IocaSed on bath faces of truss, and placed so their center lines coincide with joint
center lines.
9. Digits indicate size of plate in inches.
10. For basic design values of the CompuTrus Plate, indicated by the prefix "C', see I.C.E.O. R.R.
421 1
-@ Design assumes the top and bottom chords to be laterally braced at 2'4' a.c and at 12'4' ox.
- -. , 11. The COmpuTrus Net Section Plate is indicated by the prefix 'CN'. the designator (18) indicated 1 I 18gamaterialisused. AIJothersare2Oga
General Notes:
STRUCTURAL TRUSS INC. CERTIFIED INSPECTtON IN STRICT AGCOmMCE WITW.'U.R.C; 2321.3 pF1EpABR1cATED
.. ..
u
7 m
ul N - .. OIU
m u:
I wa
OW0
-a. sza
zzo UOW
ml-u ua.
m3 30
U 0 -I
a-u
mom
EO
0 10 VI II I- X W a a Lo In
I1
I-
-I Y
C
I C
I 5
C
I C C
5
/ m
m
v x
N
u
L".
ro%-o
m x
1
L".
T Y
N
:;* di Id e i
,I. . ,. .I_. . ----- . I ._ - . .. , -
.. U
7 m
ul N .. ODU
cn u=
I wo
ow0
-a. q:
zzo uow
un
a-u rnca
v1am 3n m'3
e0 U 0 2
- VI -
000 z
m-mom cn ZU
I H IXC ucn
woooz4
NUU 0 Ah4 UPI4U OOOrl
m0m'zo
wa
non+ aau A
zzz22;
-1c+ood ccwa zo ao om r LLU -v)
h IO* xe
.-I 0
?g "0'
-0 m
.. zz 00 33
0- U* om-
J, 1, 1, P? 22
DU vv
el-
00 au
on an
33
au
rnrn
22 au
WW cc
44 2-1
ou em
c c I c c
5
c c I
c c s
- - m
v x N
u
'T v x
N I
U
Lz!
roM-o
m 2 a
m
a
a W
-1 -1
IL
w
>
0 a a
I3
3 3 I
3 U
7
m \ m .. m
m
U VI
s - A 9 - b II L w s I- I U m 3 0 Y ln L
C
U
C
cn
c
m ."
$A 6.j d d i
..^. .- CI
U c
l-ncumw
I-CI-I- U
3
\I n I n
m
m
999 5 mom2 N-mOm ln zw
I It UYC
a==+
wooo2q
IUU 0 JCU aarau oooc3. JCI-OOO ccwa LO ao om I
oz ax
wa am
aau J zrr2q;.
LU -ul
.o 0
l- tnc XI-
20 -0 m
.. 22 - v 00 ln 13 -
O9-O
t U N
rr x
so-%-o
T
\ " .. m
m U ln
f A 9 - - r- " L w C a h U m m a 0 c) m L O
C
0 - a
C D
t
.. .. W'. I- a sh
\e
4
.. . ._
U c. !k
n U w
v)
..
ZZ 00 33
du- PO 2&
8 I1 vv
A-I UU
ww I-+ uu
aa
ai
cm vu
4-4 LO-PO-0
1
LD
v x
N
u
m
v X Lo. Y V
N \ "
In m r 0 0
-.>. m
..... ....... .: .: 1 ....... ......... - _..__- ---. .c.. - ,LL ., .. ....... _.-.-I A "f 8 ,u + I ti %s, f . .
a I 3 $!
P a
v) 6. a
VI ul 0
ur 2
na
c 1
0
-4
6-04-01 * 'i- I -..- .I ww 78 -
r r -
f - f
f E CF
k? I.
w
I
't
!I '. '
-
P P
i -
-$
i 4
u c
% e t
CI c
c k R
- p I
-
f, I 3)
J" 1
L
c-Bo1
- ..
.3 P
3
9.14 AC
/iSTA
TARY
POR. TCT. 5
IIIII
MAP 1719-LACUNA MESA TCT
ROS 6676 SEC.~I-TIIS-R~W-POR.SW 1/4
156-12
CERTIFICATE OF COMPLIANCE
PAYMENT OF SCHOOL FEES OR OTHER MITIGATION
This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City
prior to issuing a building permit. The City will not issue any building permit without a completed school fee form.
Project Name:
Building Permit
Plan Check Number:
Project Address:
A. P. N. :
Project Applicant
(Owner Name):
Project Description:
Building Type:
Residential:
Second Dwelling Unit:
Residential Additions:
Commercial/lndustriaI:
City Certification of
Applicant Information:
Number of New Dwellina Units
Square Feet of Living Area in New Dwelling
Square Feet of Living Area ‘in SDU
Net Square Feet New Area
are Feet Floor Area
gq 0 fl r-
District
San Marcos, CA 92069 (736-2200)
San Dieguito Union High School District
7 10 Encinitas Blvd.
Encinitas, CA 92024 (753-6491)
6225 El Camino Real
Carlsbad CA 92009 (33 1-5000)
Encinitas Union School District
101 South Rancho Santa Fe Rd
Encinitas, CA 92024 (944-4300)
Certification of ApplicanVOwners. The person executing this declaration (“Owner“) certifies under penalty of perjury that (1) the
information provided above is correct and true to the best of the Owner’s knowledge, and that the Owner will file an amended
certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square
footage after the building permit is issued or if the initial determination of units or square footage is found to be incorrect, and
Revlsed 4/2OlOrl
. .. . ...
SCHOOL DISTRICT SCHOOL FEE CERTIFICATION
(To be completed by the school district(s))
THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE
PROJECT HAVE BEEN OR WILL BE SATISFIED.
...................................................................................................
SCHOOL DISTRICT:
The undersigned, being duly authorized by the applicable School District, certifies that the
developer, builder, or owner has satisfied the obligation for school facilities. This is to certify that
the applicant listed on page 1 has paid all amounts or completed other applicable school
mitigation determined by the School District. The City may issue building permits for this project.
SIGNATURE OF AUTHORIZED SCHOOL
D 1 STRl CT 0 F F I C I AL
TITLE
NAME OF SCHOOL DISTRICT
DATE
PHONE NUMBER
\.. . .
Revised 4120100
?
. .- ~
.-