Loading...
HomeMy WebLinkAbout1411 BRANTA AVE; ; CB941156; PermitBUILDING PERMIT Permit No: CB941156 09/26/94 11: 17 Project No: A9401624 Page 1 of 1 Development No: Job Address: 1411 BRANTA AV Suite: Permit Type: SINGLE FAMILY DWLNG - DETACHED , Parcel No: 215-621-04-00 Lot#: 28 Valuation: 265,480 Construction Type: VN Occupancy Group: R3/M1 Reference#: CT85-35 Status: ISSUED Description: 3216 SF + 608 SF GAR + 186 SF Applied: 04/07/94 &.&#'/P~ : PORCH 94-200 AREA 14 CANTATA PLAN 3 ~W2WWuWi W262/94 Entered 14407.14 /h.&F7P7 Appl/Ownr : DAVIDSON COSCAN 619 481-8500 12865 POINTE DEL MAR #200 DEL MAR, CA 92014 *** Fees Required A** ollected & Cr ----------- -------___----____-_-------- Fees : Adjustments: Total Fees: Fee description ------------------- Building Permit Plan Check Strong Motion Fee Enter Number of EDU Enter "Y" to Autoca or manually enter Payoff Fee for CFD * BUILDING TOTAL Enter "Y" for Plumbi ~ Each Plumbing Fixture Each Building Sewer Each Install/Repair Wate Each Water Heater and/or Gas Piping System Each Vacuum Breaker * PLUMBING TOTAL 350. 14,407. Ext fe 1221. 794. 27. 2400. 4832. 540. 4666. 14480. 20. 98. 15. 7. 7. 7. 14. 168. ------- 00 00 14 'e Data 00 00 00 00 00 Y 00 14 14 00 Y 00 00 00 00 00 00 00 ------- Enter "Y" for Electric Issue Fee > * ELECTRICAL TOTAL Enter 'Y' for Mechanical Issue Fee> Single Phase Per AMP > Install Furn/Ducts/Heat Pumps > Each Install Fireplace > Each Install/Reloc Vent > * MECHANICAL TOTAL 10.00 Y 200 .25 50.00 60.00 15.00 Y 1 9.00 9.00 1 6.50 6.50 49.00 4 4.50 18.00 . I PPROVAL CITY OF CARLSBAD A 2075 Las Palms Dr., Carlsbad, CA 92009 (619) 438-1161 FINAL BUILDING INSPECTION DEFT: BUILDING ENGINEERING FIRE PLANNING U/M WATER PLAN CHECK#: CB941156 PERWIT#: CB941156 PROJECT Nm: 3216 SF + 608 SF GAR + 186 SF PORCH 94-200 AREA 14 CANTATA PLAN 3 DATE : PEWIT 04/18/95 TYPE: SFD ADDRESS: 1411 BRANTA AV LOT# 28 CONTACT PERSON/PHONE# : MW/JUSTIN/431-9541 SEWER DIST: WATER DIST: +~+GpRornD - DATE BY: INSPECTED: DISAPPROVED - INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - COMMENTS : 4 4 , c _-' FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PUNNING U/M WATER --'!IAN CHECK#: CB941156 ERnIT# : CB941156 PROJECT NAHE: 3216 SF + 608 SF GAR + 186 SF PORCH 94-200 AREA 14 CANTATA PLAN 3 ADDRESS: 1411 BRANTA AV LOT# 28 DATE: 04/18/95 PEWIT TYPE: SFD CONTACT PERSON/PHONE# : MW/JUSTIN/431-9541 SEWER DIST: WATER DIST: INSPECTE DATE BY: Rdc INSPECTED: 5/]Y/?.< APPROVED -)L DISAPPROVED - Y I INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - F .- FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING U/M PLAN CHECK#: CB941156 PERMIT#: CB941156 PROJECT NAME: 3216 SF + 608 SF GAR + 186 SF PORCH 94-200 AREA 14 CANTATA PLAN 3 ADDRESS: 1411 BRANTA AV LOT# 28 CONTACT PERSON/PHONE#: MW/JUSTIN/431-9541 SEWER DIST: WATER DIST: WATER DATE: 04/18/95 PERMIT TYPE: SFD DATE INSPECTEER. BY: 4d INSPECTED : INSPECTED DATE BY: INSPECTED: INSPECTED DATE BY: INSPECTED: Jhr APPROVED APPROVED APPROVED - 1/ DISAPPROVED - DISAPPROVED - DISAPPROVED COMMENTS : FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING U/M WATER PLAN CHECK#: CB941156 PERMIT#: CB941156 PROJECT NA13E: 3216 SF + 608 SF GAR + 186 SF PORCH 94-200 AREA 14 CANTATA PLAN 3 DATE: 04/18/95 PERMIT TYPE: SFD ADDRESS: 1411 BRANTA AV IDT# 28 CONTACT PERSON/PHONE# : MW/JUSTIN/431-9541 SEWER DIST: WATER DIST: a/ DISAPPROVED - DATE INSPECTED: ~+Z-%~PPROVED - INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - c ONSTRUCTION T ESTING & E NGINEERING INC. ESCONDIDO MODEST0 ENGINEERING, INC. INSPECTION REPORT ~ WORK INSPECTION, JOB PROBLEMS, MATERIAL IDENTIFICATION PROGRESS, WORK REJECTED, REMARKS, ECT. Post tension tendon placement inspection has been performed this date for lots 19, 22, 27, 28, 29. Comments are. as follows: Lot #27 - South perimeter location, tendon contact with vertical DWV piping. Provide adequate clearance. Lot #29 - Forming in progress @ depressed area. Verify adequate tendon support. South perimeter location, tendon supported by horizontal plumbing trap arm. Provide adequate clearance. General comment all locations - Verify adequate dead end/form clearance. Certification of compliance: All work, unless otherwise noted, ' complies with the approved plans, specifications and uniform building code. Inspector: Certification No. L!., &l?n 4' d,-m Date: 7A OLr 44 GEOTECIINICAL Rr CONSTRUCTION ENGINEERING TESTING 9r INSPECTION 3.540 OhKDALE ROAD IMODFSTO, CA 95355 (203) 551-2271 FAX (209) 551.3593 2414 VlNEYAHD AVENUE SUITE C UCONDIDO, CA 92029 (619) 746-4955 FAX (619) 746-9806